Loading...
HomeMy WebLinkAboutGLENN VIEW ESTATES WEST PH 1 BLK 1 LT 3Glenn View Estates West #1 Block 1 Lot 3 #051-793-03 'r Municipality Anchorage ..°1, ,Y.4,. of • .1- Development Services Department Building Safety Division s .. On -Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW010440 PID Number: 051.793.03 r . of Name: Arctic Devco, Inc. Wastewater System: LNew ❑ Upgrade Address: PO Box 3489 Palmer. AK 99645 ABSORPTION FIELD Phone: Number of Bedrooms: D Deep Trench ® Shallow Trench 0 Bed 0 Mound 0 Other. LEGAL DESCRIPTION Soil Rating: 0.6 GPO/FP Total Depth from original grade: 4.0 Ft. Block: Lot Subdivision: 1 3 Glenn Vw. Estates West Phase 1 Depth to pipe bottom from original grade: 1.7 Ft. Gravel depth beneath pipe: 2.2 Ft. Township: Range: Section: Fill added above original grade: 1.3.2.8' +/- FL Gravel Length: 148 Ft. Well: • New • Upgrade Gravel width: 5 Ft. Number of lines: 2 Distance between lines: 10 FL Classification (Private. A, B, C): Public Total Depth: FL Cased to: Ft. Total absorption area: 1060 Ftp Pipe Material: D3034 & F810 Dnller. Date Drilled: Static Water Level: FL Installer. Turner Const. Date Installed: 10/30/2001 Yield: GPM Pump Set at Casing Height Above Ground: Ft., FL TANK SEPARATION DISTANCES C4 Septic • Holding • S.T.E.P. • Other: To From Septic Tank Absorption Field Lift Station Holding Tank Public/Private Sewer Line Manufacturer. Greer Capacity 1250 Gal. Well 200'+ 200'+ NA NA 25'+ Material: Steel Number of Compartments: 2 Surface Water 100'+ 100'+ NA NA LIFT STATION Lot Line 5'+ 10'+ NA NA Size: Gat. Manufacturer. Foundation 5'+ 10'+ NA NA Pump on level at In. 'Pump oft" level at in. High water alarm at: In. Curtain Drain NA *50'+ NA NA Pump Make 8 Model Electrical Inspections performed by: Remarks: *none known BENCH MARK Insulation over tank & field Location and Description: Garage Slab i Assumed Elevation: 100 FL Engineer's Stamp 4"bE OF A 4. 1%. ar II 0'k;• 9TH p•... *.... @•e•. ... ill osi- .. • ....•, •,•,. +1 Kenneth M. Du : �� J':• CE 7116 • ��/ '�4p_e ••. ..••• �vs t;ep RO•*....0 ``42.044' -". Inspections performed by: KND Engineering, Inc. Dates: 1st 10/3012001 2nd 10/31/01 Development Services Department A proval3 t'Gl2s o 1 Reviewed and approved by: `/J/� 4/. Date: .7—//— 0 2— (Rev. 12/00) AS -BUILT SYSTEM DETAILS/SITE PLAN Permit SW010440 GLENN VIEW WEST ESTATES S/D, LOT 3, BLOCK 1 PID#051-793-03 SEPTIC Lot -4' fC° K Lot 3 ZABEL SPLITTER VACANT EXISTING 1250 GAL SEPTIC TANK FC0 A -C= 33.0' B -C= 16.5' A -D= 30.5' B -D= 24.2' A-E= 64.4' B-E= 55.2' A -F= 68.9' B -F= 67.1' A -G= 28.2' B -G= 63.6' A -H= 15.7' B-H= 52.3' CLCAIQJT INS CLEANOUT Ana •:III:1 I_1:1 —.1250 GAL Tag SEPTIC:(= TANK SCALE: NTS II�Jr�ii•�w SCALE: 1' 50' rONITOR TUBE FINAL GRADE fn.TCR fAYUC\ �INSULATI l MONITOR TUB 0100.3 95.7 93.4 SEWER ROCK TRENCH 1 .MONITOR TUBE CLENQJT_ 98.7 74' FINAL GRADE CANOUT Ara":s'°FAL�� KENN FF D �'IibFESSIO14p= CE -7116 fILTCR fARRIC \ /INSULATI[M • t"-9s.7?� SEWER ROCK TRENCH 2 74' MONITOR TUBE CLCANDUT 99.06 .. h - VARIES 9s.7 1� '3�3'• t2• I 84.40 PREPARED FOR: REX TURNER ARCTIC DEVCO, INC. P.O. BOX 3489 PALMER, ALASKA 99645 SCALE: NTS 111 FIELD BOOKS COMPUTED: 90UNOARY: LANG DRAWN: VBG STAKING: LANG CHECKED: ASDUILT: LANG DAn' 6/26/02 OHC. FILE: GRID: ACRD FILE: 01100.DWG NW1459 Jos Na: 01100 END ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 Lot 4 15' TELECOM. 8 ELECT. EASEMENT c; NORTH WOODS SUBD. UNIT III 1 N 89°59'0311E 144.40' 15' TELECOM. 8 ELECT. EASEMENT 10' BUFFER — LANDSCAPING EASEMENT • Lot 3 41,953 s.f. SEPTIC CLEAN -OUTS )foomPttinor-1 PLOT PLAN ASBUILT k SCALE IN ' 5°' GRID Lang acAssociates, Associates, inc. 11500 Daryl Avenue, Anchorage, Registered Land Surveyors (907)• 522-4625 Fax 1 hereby certify that 1 have surveyed the following described property: Lot 3, Block 1. GLENN VIEW ESTATES WEST, Phase No. 1 Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission Tines or other visible easements on said property except as indicated hereon. Dated this the 2-s Day of APR.LL. Lot 2 NW 1459 . ?.002 at Anchorage. Alaska It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. Lot 1 ,19'911 3.91,£1,00 S 30.00' Project No. 01-165. Alaska 99515 "7 O ,gO°o4 O?: 4918 . 1k• e`c, :KENNETH b. L �'•. •GyJ�: • 4J!LS-52024jVPA••••••r....• p�ssioN '�7 O000 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial /6/ 50/6 / lb:$b,o-ii t /: �p /6/v( !/ A'w. Date Issued: Oct 18, 2001 Expiration Date: Oct 18, 2002 Permit Number: SW010440 Parcel ID: 051-793-03 Legal Description: GLENN VIEW ESTATES WEST PH 1 BLK 1 LT 3 Design Engineer: 0070 KND Engineering Owner Name: Turner Construction Owner Address: PO Box 3487 Palmer , AK 99645 - Site Address: Lot Size: 41953 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: Disposal Field Q✓ Septic Tank rj Holding Tank 0 Privy ❑ Private Well 0 Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By Issued By: Date: /d/ —a 41 Date:/0 -la-al Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I D D 5 1 - 7C(3 — d3 Permit Number SW 0%1440 Property owner(s) Turner Construction Day phone 242-4555 Mailing address (1) PO Box 3487, Palmer,AK 99645 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd_) Glenn View Estates West Ph1, Block 1, Lot 3 Legal description (Section, Township & Range) Lot Size 4.Q.,000+ Acres/Sq.Ft. Number of Bedrooms 4 yi THIS APPLICATION IS FOR: Sewer Only ® Well Only Sewer and Well ❑ Water Storage Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi Swimming Pool ❑ Water Softening Unit Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: (Rev. 12/00) Waiver Fees: Date of Payment: Receipt Number: ]KNENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 October 11, 2001 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: New sewer permit — Glenn View Estates West Phase 1, Block 1, Lot 3 Gentlemen: The owner has requested we proceed forward to obtain a septic permit on the subject lot. On April 20, 1999 and October 1, 2001 testholes were excavated for the proposed septic system. The results of these tests are attached. The general slope of this lot is flat or of moderate slopes from east to west at a grade of approximately 0 - 3%. We have designed our system utilizing the testholes we excavated for the 4 -bedroom house, which is proposed for this lot. The lot will be served by public water. We propose to install a 5' wide shallow trench. Water was not encountered during the excavation or monitoring. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, MID Engineering Kenneth M. Duffus, P. Attachments: On -Site Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test WELL & WASTEWATER DISPOSAL SYSTEM DETAILS/SITE PLAN KND GLENN VIEW WEST ESTATES S/D, LOT 3, BLOCK 1 SE ot) 5 Lot 6 VACANT Lot 3 i�oo ww orm+ VACANT Dt 8 Lot 2 Lot 7 NO PUBLIC WELLS WITHIN 200. OF PROPOSED SYSTEM. NO PRIVATE YELLS WITHIN 200' OF PROPOSED SYSTEM EXCEPT AS NOTED. NO SEPTIC SYSTEMS WITHIN 200. Or PROPOSED WELL EXCEPT AS NOTED. SEPTIC Lot . AksN * '4 • H " 7*� KENNETH ' DU CE -7116 ""oFESS100' DESIGN DETAILS 4 BDRM X 150 GPD = 600 GPD 600 GPD/.6 GPD PER SO. FT. (8.89 MIN/IN.)= 1000 SO. FT (1000/5'(W)) X .70(RF) (2.0' GRAVEL) = 140 FT. TRENCH USE 2 TRENCHES - 70 (L) X 5' (W) X 2.0'(D) Total depth of system is 4.0' from original grade. Total depth of' gravel below distribution pipe is 2.0' NOTES: 1. USE 1250 GAL SEPTIC TANK AND INSULATE IF < 4' OF COVER. 2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM. 3. CONTRACTOR WILL ENSURE MINIMUM 2X SLOPE INTO SEPTIC TANK. 4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN. 3' COVER IF REQUIRED. 5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS, SEPTICS, LOT LINES, FOUNDATIONS & ALL OTHER SETBACKS. PREPARED FOR: REX TURNER ARCTIC DEVCO, INC. P.O. BOX 3489 PALMER, ALASKA 99645 Scate: 1'= 100' PAGE 1 OF 2 FIELD BOOKS CouPUTEo: e0UNDARY: LANG 0RA1YN: VBG STAKING LANG cxEcx(o: KMD ASBUILT: LANG °ATE: 10/9/01 Dw6. FILE: CRIo: NW1459 ACRD FILE: 01100.DWG d'e No.: 01100 ItN RD ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 KND WASTEWATER DISPDSAL SYSTEM DETAILS GLENN VIEW WEST ESTATES S/D, LOT 3, BLOCK 1 FLA TH#01-0 co MT FLAT Lot Z200 FLOW DIVIDER PROPOSED 1250 GAL SEPTIC TANK FCO CO CO 10 CO FLAT� PROPOSED 4 BDRM HOUSE PREPARED FOR: REX TURNER ARCTIC DEVCO, INC. P.O. BOX 3489 PALMER, ALASKA 99645 Scale: 1'= 20' PAGE 2 OF 2 FIELD BOOKS COUPUTED: BOUNDARY: LANG DRAWN: VBG STAKING: LANG CHECKED: KM D ASBUILT' LANG DWG FILE: DATE: GRID: 10/9/01 NW1459 ACAD FILE' 01100.DWG doe No.: 01100 END ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 • KNLJ ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 Performed for: Project: 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20 - SOILS PERCOLATION TEST Arctic Devco Lot 3, Block 1, Glenn View West i.••• ,� ... ; Kenne,n i.1. Dui 44 44of r C• CE 7116 4 q•o••�(�c'.s. O O •••e....• , 4 �1 ROFESSIO\ ' Date Performed: 4/20/99 TEST HOLE # 99-1/3 Depth (Feet) Org/SM — rootmat red/brown SM/GM —loose red/brown SM/GM —brown/gray, loose w/cobbles to 8, sand in high quantity w/ some silt, increasing density w/ depth B.O.H. SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? No Depth to water after monitoring? NO What depth? NA Date? 05/15/99 Reading Date Gross Time Net Time Depth to Water Net Drop 1 4/20/99 12:00 - 8" - 2 12:30 30 min 4 7/16" 3 9/16" 3 12:30 - 4 7/16" - 4 1:00 30 min 11/16" 3 6/16" 5 * 1:01 - 8" - 6 2:31 30 min 410/16" 36/16" * Water Added Percolation Rate 8.89 (min/in) Perc Hole Diameter 6" Test Run Between 3 feet and 4 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. KND ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 Performed for: Project: Depth Feet) 2- 3- 4- 5- 6- 8- 9- 10- 11- 12- 13- 14- 15 - SOILS PERCOLATION TEST Arctic Devco :E 9F'A.gs-a1 i10�• TH '"�A`,, *+ISI ...•. ....- .••. .. • r F . 4014: 44,4 Itt Kenneui iv ... u� j� J, •.• CE 7116 8 �'`ROFESS\O' ' Date Performed: 414070131;..6;-.'\1\\*. 0/01 /� ..6 Glenn View West B1, L3 TEST HOLE # 01-01 Org — w/ red -brown overburden GM/GP - brown dry loose gravel SM/GM — gray/brown silty sand and gravel , w/cobbles to9", dry firm density ity increasing w/ depth B.O.H. 16- 17- 18- 19 - HOLE PRESOAKED 20- PRIOR TO TEST SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? NO Depth to water after monitoring? DRY What depth? NA Date? 10/09/01 Reading Date Gross Time Net Time Depth to Water Net Drop 1 10/4/01 1:00 - 8" - 2 1:30 30 min 512/16" 2 6/16" 3 * 1:31 - 8" - 4 2:01 30 min 511/16" 2 4/16" 5 * 2:02 - 8" - 6 2:32 30 min 511/16" 2 5/16" * Water Added Percolation Rate 13.33 (min/in) Perc Hole Diameter 6" Test Run Between 4 feet and 5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-793-03 HAA # i- 09-D Oca Expiration Date: % — % /" O 3 1. GENERAL INFORMATION Complete legal description Glenn View Estates West Phase 1, Lot 3, Block 1 Location (site address or. directions) NSA Linda Jo Circle, Chugiak, AK 99567 Current Property owner(s) Arctic Devco, Inc. Day phone (907) 745-8334 Mailing address PO Box 3489 Palmer, AK 99645 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System TYPE OF WASTEWATER DISPOSAL: ❑ Individual On-site ❑ Individual Holding tank ❑ Community On-site • Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm KND ENGINEERING, INC. Address 20441 Ptarmigan Blvd., Eagle River, AK 99577 Phone (907) 696-6111 Engineer's Printed Name Kenneth M. Duffus Date7,( 11 .0•OF.s A( 4ltl s * j4 I•t o • Kenneth M. D f7 j 5. DSD SIGNATURE 4 c�t.•••. CE 7116 • ; ®� V- Approved,t`kk0b0RopEsS0'...+— for /� bedrooms. >ta�`"_`�`� Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments \tOt -cy Tr4 %. = ON-SITE •^ '.�0' m • WASTEWATER : PROGRAM fit!' i ' TIENT SEA \\ Attachments: HAA Checklist Septic System Advisory Well Flow Advisory X Maintenance Agreements Supplemental Engineer's Report Other (Rev. 0i102) Original Certificate Date: %-1/— 02_ , , Legal Description: Glenn View Estates West Phase 1, Lot 3, Block 1 'iI: A. WELL DATA t - Well type" -PUBLIC If A, B, or C. provide PWSID # We I Log (Y/N) il Date completed Sanitary seal -(Y/N) ' Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height (above ground) FROM WELL LOG AT INSPECTION Municipality of Anchorage Development Services Department Building Safety Division On -Site Water, & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ' t HEALTH AUTHORITY APPROVAL CHECKLIST Parcel ID: 051.793.03 Date of test Static water level I •i • Well .production g.p.m WATER SAMPLE RESULTS: ft. ft. g.p.m. Coliform colonies/100 ml. Nitrate mg./1 Other bacteria colonies/100 ml. Arsenic:mg./l. Date of sample: Collected by:' ! B. SEPTIC/HOLDING TANK DATA Tank Type/Material septic/steel Date installed 1013012001 Tank size '1' 1250 gal. Number of Compartments 2 Cleanouts (YIN)' Y • I'I Foundation cleanout (Y/N) "Y Depression over tank (Y/N)N_High water alarm (YIN) N Date of pumping NA - New tank Pumper C. ABSORPTION FIELD DATA Date installed 101301011' Soil rating (g.p.d./f12 ft2/bdrm) 0.6 Length l! 148 , ft. Width 5 ft. Gravel below pipe 2.2 ft. Total depth 6_6 ft.: Eff. absorption area 1060 ft2 Monitoring tube Y Depression over field N Date of adequacy test NA- New System Results (Pass/Fail) Pass Fora4 bedrooms in. Water added - ga Absorption System type Shallow Trench Fluid depth in absorption field before test Elapsed Time: min. Final fluid depth in. Any rejuvenation treatment (past 12 mo.) (Y/N & type) New depth in. ate >= g.p.d. If yes', give date D. LIFT STATION Date installed NA Size in gallons "Pump on" level at _ in. Manhole/Access (Y/N) "Pump off' level at in.High water alarm level at in. Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer /septic service line Meets alarm & circuit requirements? On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Water main 10'+ Wells on adjacent lots 200'+ Property line 5'+ Water service line 10'+ Absorption field 5'+ Surface water 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water Service line 104 Surface water 100'+ Curtain drain 50'+ F. COMMENTS Wells on adjacent lots 200'+ Water main 10'+ Driveway, parking/vehicle storage 2'+!. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Kenneth M. Duffus Date 07103102 s OF qc h o'43 •'''...•............. ,,. ,'7 °•s 1, It . • iCo * : C. *IPI 1.. , rte.... ... .. A� . SCE 7116 a�'✓� i`'T/1 F,1P , �w gib HAA Fee $375.00 Date of Payment 07/03/02 Receipt Number (Rev. 12/01) Waiver Fee $ Date of Payment Receipt Number