HomeMy WebLinkAboutSTEWART #1 BLK 2 LT 5St'..... wart #1
Block 2
Lot 5
#050-472-59
Municipality of Anchorage °•.
Development Services Department
Building Safety Division , , r °
On -Site Water and Wastewater Program, 4700 S. Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650 Page of
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SWO20251 PID Number: 050-472-59
Name:
Royce B.- Martin Wastewater System: ® New ❑ Upgrade
Address:
PO Box 773326 Eacile —River. AK 99577 ABSORPTION FIELD
Phone: Number of Bedrooms:
644-6819 5 0 Deep Trench 0 Shallow Trench 0 Bed 0 Mound 0 Other:
LEGAL DESCRIPTION Soil Rating: Total Depth from original grade:
1.2 GPD/Fl�
Block: Lot: 9.0 Ft.
Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe:
2 5 STEWART #1 2.99 Ft. 5 FL
Township: Range: Section: Fill added above original grade: Gravel Length:
-0.45 Ft. 65 Ft.
Well•• ❑ New ElU rade Gravel width: Numberoflines: Distancebetween lines:
Upgrade 2.0 Ft. 1 NA FL
Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material:
PUBLIC Ft. Ft. 650 Fe D3034 & F810
Driller. Date Drilled: Static Water Level: Installer. Date Installed:
Ft. Martin Const. Co. 6/4/03
Yield: Pump Set at: Casing Height Above Ground:
GPM F,. TANK
Ft
SEPARATION DISTANCES ® Septic ❑ Holding 0 S.T.E.P. ❑ Other.
To Septic Absorption Lift Holding Public/Private Manuaclurer: apaGty:
From Tank Field Station Tank Sewer Line Anchorage Tank 1500Ga1.
Well 200'+ 200'+ NA NA 25'+ MJteel N umber of Compartments:
2
Surface Water
100'+
1001+
NA
NA
Lot Line
5'+
10'+
NA
NA
Foundation
5'+
10'+
NA
NA
Curtain Drain I
NA
*50'+
NA
NA
Remarks:
Tank & Field
Insulated.
6'
of sewer
rock installed
w/ only
5'
calculated
for absorption
area. .
*none
known
LIFT STATION
in.I
Pump Make 8 Model I ElecWcal
Door sill
BENCH MARK
umed Elevation:
100 Ft.
In.
Engineer's Stamp
.�
�tA� AL
•O 0000:
Inspections performed b KND En p st / ,,;•`� , ,;;�•�oO
Y 9117[lag, Inc_Dates:1 6/04/2003
o
2nd 6/ • i000 00.00900•. • :•��
Development Services Department Approval g'4 VagJo4 I� :V-) *% CE 7116 f �•i
Reviewed and approved by:AAJ:A •°•• •
(Rcv.12/00) Date: 0 �g No* 0......•• P _o'
AS -BUILT SYSTEM DETAILS/SITE PLAN Permit SW020251
STEWART #1, LOT 5, BLOCK 2 PID#050-472-59
126 DRIVE LETS
r
SERVED
BY PUBLIC
WATER
Ko
N
-
EXISTING 5
4
BDRM HOUSE
SVACANT
6
FC A B
THBKND2001-0
SEPTIC
EXIS NG 1500
GAL S TIC TANK
O E ISTING PRIMARY FIELD TCO—F
ROPOSED RESERV FIELD
SCALE, 1' = 50'
A—C= 20.2' 95.82
95.6
B—C= 60.0' W
g
A—D= 30.4'
B—D= 64.0'
94.6 FINAL GRADE
94.6
C3
A—E= 56.7'
MSLLAT[pl VARIES
B -E=101.8' A 1500 GAL
A -F= 44.3' H SEPTIC 92.14Z ;:': :r:; : '.r =. 92.14
�... `,.`;::.•
..,...... ... •,.,,'
TANK
B—F= 49.3'
�` °'.�°:..'�:4 ..
'" * - SEWER ROCK' •: : ,
• sr
92.7
92.5 86.14
86.13
�"�`` \
.Aw�F,46,
65.0'
..............
1
PREPARED FOR.
SCALE, NTS
78.13 ew
��'.
,
ROYCE MARTIN
,Of�:`
TH
PO BOX 773326
*, 4 *
EAGLE RIVER AK, 99577
/ /
(907) 694-6819
....._ ................................
"'
�. � ET' �""""'�
CE -7116 %
FIELD eooKs coMPurM ENGINEERI
w�
eouNOARr. LANG VBG
STAKING:
NG
:: ti
1 '
LANGCNea� KMD 20441 PTARMIGAN BLVD.
�°�ss1o��•ti i
AsevaT. LANG DAV_ 03 15 04
EAGLE RIVER, AK 99577-8736
owc. nm aao NW57
..............................
ACAo Fm-01038.DWG Jw Na: 01038 (907)696-6111/FAX (907)696-8111
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Renewal
Permit Number: SW020251
Legal Description: STEWART #1 BLK 2 LT 5
Design Engineer: 0070 KND Engineering
Owner Name: ROYCE MARTIN
Owner Address: PO BOX 773326
EAGLE RIVER, A 99577 -
Date Issued: Jul 29, 2002
Expiration Date: Jul 29, 2003
Parcel ID: 050-472-59
Site Address: 021400 LOWLAND AVE
Lot Size: 24750 SQ. FT.
Total Bedrooms: 5 Permit Bedrooms: 5
This permit is for the construction of:
0✓ Disposal Field Z✓ Septic Tank E] Holding Tank E] Privy F] Private Well Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
9
-' " G'.S ' f -d
G o' -pt ", e"3a_ ec
X - Date: 7/
Z -q /0 Z
Y�2 Date: 7 2 9/O?_
�- - Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. Q S5-0 — V—/ -Z I Permit Number SWO202s/
Property owner(s) Royce Martin Day phone 694-6819
Mailing address (1) p.o. box 773326 Eaale River Ak
Mailing address (2) Zip Code 99577
Legal description (Lot, Block & Sub'd.) Stewart #1. Blk 2 Lot 5
Legal description (Section, Township & Range)
Lot Size Q_,�w Acr
-e�w7SC;)
THIS APPLICATION
Number of Bedrooms 5
Sewer Only ® Well Only ❑
Sewer and Well ❑ Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees: �I�F,(/�l�#L
Date of Payment:
Receipt Number: 0 /9¢ 04 -
(Rev. 12100) -
Waiver Fees:
Date of Payment:
Receipt Number:
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Permit Number: SWO10199
'Legal Description:. STEWART #1 BLOCK 2 LOT 5 .
Design Engineer: 0070 KND Engineering
Owner Name: ROYCE MARTIN
Owner Address: PO BOX 773326
EAGLE RIVER , A 99577 -
Date Issued: Jun 20, 2001
Expiration Date: Jun 20, 2002
Parcel ID: 050-472-59
Site Address: 21400 LOWLAND AVE
Lot Size: 24750 SQ. FT.
Total Bedrooms: 5 Permit Bedrooms: 5
This permit is for the construction of:
Disposal Field M Septic Tank E] Holding Tank 0 Privy
All construction must be in accordance with:
1. The attached approved design.
Private Well r-1 Water Storage
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
r
Received By:
04vnl
Date: —0 1
i r
Issued By: A
Z Date: 6 — 2 0 —0J
- Municipality of Anchorage
I' • y Development Services Department •'`"� 4,
t
'W
' Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St. �tp
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 05-0 - V7,z I Permit Number SW O / O /99
Property owner(s) Royce Martin - __10k i -- Z,o np yrd Day phone 694.6819
Mailing address (1) p.o. box 773326 Eagle River Ak
99 address (2) 2111 bO /A- Ie- Zip Code 99577
Legal description (Lot, Block & Sub'd.) Stewart #1. Blk 2, Lot 5
Legal description (Section, Township & Range)
Lot Size q 7iv Acres Number of Bedrooms 5
THIS APPLICATION IS FOR:
Sewer Only ® Well Only ❑
Sewer and Well ❑ Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi (�.
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
certify,# t the ove information is correct. I further certify that this application is being made for a
Sing El amity ng and is in accordance with applicable Municipal Codes.
(Suture of property owner or authorized agent)
Permit Fees: X20: oc Waiver Fees:
Date of Payment: G, l c ,Lo % Date of Payment:
Receipt Number: S3S l Receipt Number:
(Rev. 12/00)
KND ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)696-6111/FAX (907)696-8111
May 17, 2001
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: New sewer permit — Stewart #l, Block 2, Lot 5
Gentlemen:
The owner has requested we proceed forward to obtain a septic permit on the subject
lot. On April 27, 2001 we dug one testhole for the proposed system. The results of this
test are attached. The general slope of this lot is from north to south at a grade of
approximately 1-3%.
We have designed our system utilizing the testhole we excavated for the 5 -bedroom
house, which is proposed for this lot. The lot will be served by public water. We
propose to install one 2' wide deep trench. Water was not encountered during the
excavation or monitoring.
There are no public or private wells within 200' of our proposed system location except
as noted. There is no surface water within 100' of the proposed system and there are no
known curtain drains within 50'. We do not expect there to be any adverse effect on
adjacent lots by the development of this system.
If you have any questions, please contact me at 696-6111/FAX 696-8111.
Respectfully submitted,
ASHD Engineering
Kenneth M.�n,,ff.,q,P.E.
Attachments: On -Site Well and Sewer Application
Wastewater Absorption System Details/Site Plan
Soils Log/Percolation Test
WELL & WASTEWATER DISPOSAL SYSTEM DETAILS/SITE PLA
I STEWART #1, LOT 5, BLOCK 2
1
olll
DESIGN DETAILS
5 BDRM X 150 GPD = 750 GPD
750 GPD/1.2 GPD PER SQ. FT. (1.68 MIN/IN.)= 625 SQ. FT
(625/(2'(W) X 6'(D))) (6.0' GRAVEL) = 52.1 FT. TRENCH
USE 1 TRENCH - 52 (L) X 2' (W) X 6.0'(D)
Total depth of system is 10.0' from orlglnal grade.
NO PUBLIC WELLS WITHIN Poo- OF Total depth of gravel below dlstributlon pipe Is 6.0' .
NO PRIVATE WELLS VM41N Par OF N❑TESi
PROPOSED SYSTEM EXCEPT AS NOTED 1. USE 1500 GAL. SEPTIC TANK. INSULATE IF <4' OF COVER.
NOP�EI) SWELLEXEXCEP� NOPODrEn°F. 2. INSULATE TRENCH WITH 2' HD BURIAL FOAM.
3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK.
4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE
MIN. 3' COVER IF REQUIRED.
5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT
WELLS & SEPTICS.
OF<Q� 1 PREPARED FOR,
�,`� 1 ROYCE MARTIN
26
* : 1H a * EAGLE RIVER AK 99577 Scale) 1'= 100'
__.............._.... ......�...._ .I (907) 694-6819 PAGE 1 OF 2
...
....
............ ..............
FlELD BOOKS CouPvtED
11
CE M. D �dV ENGINEERING
'•t CE -7116 � eauwARr ANG uRAr�N: VBG 4 �• M r H STMON@ LANG CHECXm: KMD 20441 PTARMIGAN BLVD.
AsamT: NG DAM 5 15 101 EAGLE RIVER, AK 99577-8736
33IO�� win HxE
cRro: NW57
AQAD FLr- 01038.DWG iJOe No: 01038 (9D7)696-6111/FAX (907)696-8111
KNID
�n
WASTEWATER DISP❑SAL SYSTEM DETAILS
STEWART #1, LOT 5, BLOCK 2
i 1 1 Di-)Ml"I nuu".5r-
PR❑P❑SED
GARAGE
TH#KN,11�2001-01
M
MIN, T FC❑
r/� PROPOSED 1500
Q
COAmAT5
GAL SEPTIC TANK
MIN.
MT PRbM7SED PIM N Y FIELD
[PROPOSED RESERV FIELD
0' MIN.
PREPARED FOR,
ROYCE MARTIN
GX n EA BOX 773326
7 EAGLE RIVER AK, 99577
_... _........ _.................._ ..__... '... -- I (907) 694-6819
..... _.. i_ ............ _ .......... FIELD BOOKS compu7m.
KDQNEM . D
% CE -7116 Bauouar. LANG MAM:
srAma LANG aEc' KMD
A=xT- LANG DAM 5/15/
�. W- ME: Nw57
AcD rLL' 01038 '10B N°` 01038
Scales 1'= 20'
�PAGE 2 OF 2
UK�qM) ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)696-6111/FAX (907)696-8111
'f.
(U
'^
un 'J
`V
'^
LJn ,J
`V
PREPARED FOR,
ROYCE MARTIN
GX n EA BOX 773326
7 EAGLE RIVER AK, 99577
_... _........ _.................._ ..__... '... -- I (907) 694-6819
..... _.. i_ ............ _ .......... FIELD BOOKS compu7m.
KDQNEM . D
% CE -7116 Bauouar. LANG MAM:
srAma LANG aEc' KMD
A=xT- LANG DAM 5/15/
�. W- ME: Nw57
AcD rLL' 01038 '10B N°` 01038
Scales 1'= 20'
�PAGE 2 OF 2
UK�qM) ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)696-6111/FAX (907)696-8111
KND ENGINEERING
20441 PTARMIGAN BLVD.
OF A4.4h,
.• Gj , .'f.91
EAGLE RIVER, AK 99577-8736
Kenneth M. Duffus
�r 4% CE 7116
+t �F9 • • • •''wAw
SOILS PERCOLATION TEST%Fop''"""'• P�
Performed for: Royce Martin Date Performed: 04/27/01
Project: Stewart #1 Block 2 Lot 5 TEST HOLE # 2001-01
Depth
(Feet) SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Org/SM —black/red overburden
2-
3-
A-
5-
6-
7-
8-
9-
10-
11-
12-
13.
14
15
16
17-
W/ organics, moist
silty sand
SP/GP — gray gravely sand,
moist, firm density
_: <" '-"' B. H.
18-
19 -
HOLE PRESOAKED
20- PRIOR TO TEST
Was Ground water encountered? NO What depth? NA
Depth to water after monitoring? NO Date? 5/04/01
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
5/8/01
1:00
-
8"
-
2
1:10
10 min
111/16"
65/16"
3
1:11
-
8"
-
4
1:21
10 min
113/16"
63/16"
5
1:22
-
8"
-
6
1:32
10 min
2"
6"
7
1:33
-
8"
8
1:43
10 min
21/16"
515/16"
9
*
1:44
-
81"
10
1:54
10 min
21/16
515/16"
11
1:55
-
8"
12
2:05
10 min
21/16
515/16"
*
Water
Added
-
Percolation Rate 1.68 (min/in) Perc Hole Diameter 6"
Test Run Between 4 feet and 5 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in
effect on this date.
Municipality of Anchorage
Development Services Department
Building Safety Division all
On -Site Water and Wastewater Program
4700 South Bragaw St. `A
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904,
CERTIFICATE OF HEALTH AUTHORITY APPROVAL r
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 050-472-59 HAA # QLAy 1
Expiration Date: �t - " q' 0 .�
1. GENERAL INFORMATION
Complete legal description Stewart 91 Block 20 Lot 5
Location (site address or directions) - 21400 Lowland Ave_ Eagle River, AK 99577
Current Property owner(s) Royce Martin Day phone 694-6819
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup.
Day phone
Day phone
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
❑
Individual On-site
Individual Water Storage
❑
Individual Holding tank
❑
Community Class Well
❑
Community On-site
❑
Public Water System
®
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional
civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the
transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal
and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health
Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well
and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one
year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or
a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As', certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the 'Health Authority Approval Guidelines for this
application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional
and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all
applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm NZ!D ENGINEERING- Inc- Phone*(907) 696-6111
Address 20441 Ptarmigan Blvd.- Eagle -River- AK 99577
Engineer's Printed Name Kenneth M. Duffus Date 04/22/2004
Engineer's Comments:
This investigation was completed in compliance with
ADEC and MOA regulations. The assessment of the
condition of the well and septic applies only to the
conditions as of the day tested. The flow and absorption
rates may change due to subsurface conditions that
may not be observed from the surface, changes in
land use, local soil characteristics, groundwater levels
that may fluctuate during the year and the water usage
of the family being served by the system. The operational
life of all well and septic systems are subject to these
various and dynamic characteristics and are outside the
control of the evaluator of the well and septic system.
Therefore, KND can not give any estimate of how long a
system will function satisfactory for current or future
occupants or can KND guarantee that no unseen
encroachments, deficiencies or discrepancies exist.
5. DSD SIGNATURE
® iw •.•• rel g &G 1 .'� ••.• OB
�••O.1•b1U•1N1 1N• .��•••�_1•
f• •11•NN•i. • • •.1 .. j
9 Kennettz M. rr;rf� a (j
,�1 �• CE 7116 V",
40
Aw
�� Approved for bedrooms.
Disapproved.
Conditional appeoval for bedrooms, with the following stipulations: llttttl
'N ,.
llll(�A*,1 GRE
�r��
4-::Z; WATERAND : R'
R:
PROGRAM
Attachments:
HAA Checklist X Maintenance Agreements
Septic System Advisory Supplemental Engineer's Report
Well Flow Advisory Other
• ..-*&6,
X11111)11
By:Original Certificate Date: L7L
D. LIFT STATION
Date installed NA Size in gallons Manhole/Access (Y/N)
"Pump on" level at in., "Pump off' level at • in -High water alarm level at
in.
Datum Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot On adjacent lots
Absorption field on lot On adjacent lots
Public sewer main Public sewer manhole/cleanout
Sewer /s1eptic service line
Holding tank
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5 ' + Absorption field 5'+
Water main 10'+ Water service line 101+ Surface water 10 0' +
Wells on adjacent lots 200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT, TO:
Property -line 10'+ Building foundation 10'+ Water main 10'+
Water Service line 10'+
Curtain drain 50'+
F. COMMENTS
Surface water 10 0' + Driveway, parking/vehicle storage
Wells on adjacent lots 2 0 0'+
OF 44 %I
G. ENGINEER'S CERTIFICATION `-� •�• '99�
r
l certify that I have determined through field inspections and / 0
review of Municipal records that the above systems are in •• •........... .....
conformance with MOA HAA guidelines in effect on this date. I Kenneth M. pu=re; t
hSit . . .i
Engineer's Printed Name Kenneth M. Duffua 1���9 `�.;���I� •..•' �v.:
�.1 1N 'P190FESSIO�A
Date -04/22/04 \\eo�.e��.�
HAA Fee `'$430.00 Waiver Fee $
Date of Payn! ' '12 G,/fly Date of Payment
Receipt Number Receipt Number
(Rev. 12/01) ,
LOWLAND ROAD
-- r - - - -
L
g .
9
S 89059'00`E 123.75
LOT 4
N 89.59'00' W 123.75
EAGLE RIVER ROAD
LOT 6
PLOT PLAN ASBUILT .— SCALE 10.' 30' GRID NW 57 Project No. 01_060
Lang & Associates,. Inc ..11500 Daryl Avenue, Anchorage, Alaska 99515
907 522-6476 Phone
Registered Land Surveyors (907) 522-4625 Fax QF ,q
I hereby certify that I have surveyed the following described property: '��'•'''.......��ts
LOT 6, STEWART SUBDMSiON, UNIT No. 1
thereon re within the roe lines and do not encroach
onto t situated
Anchorage Recordin District. Alaska, and that the Improvements
property �Y roach onto the property ...............................
adjacent thereto. that no improvements on .the eroperly lying adjacent thereto
encroach on the surveyed premises and that then are no roadways, transmission
lines or other visible easements on sold properly except as indicated hereon. " %KEN ' ' .. "' """;�
'.KEN 0
Dated this the �� Day of Cot�`a"' , 29106 - at Anchorage. Alaska —520
It is the responsibility of the owner to determine the existence of any easements. """'•$
covenants, or restrictions which do not appear on the recorded subdivision plat. 100'
4z -