ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SWO10277
PID Number: 017-072-11
Name:
Kenneth E. Brown
Wastewater System: ❑✓ New E3 Upgrade
Address:
2811 E. 46th Avenue Anchorage, AK 99510
ABSORPTION FIELD
Phone:
230-]921
Numberof Bedrooms:
3
V Deep Trench ❑Shallow Trench D Betl ❑ Mound ❑Other
LEGAL DESCRIPTION
Sal Rating:
as
Total Depth from original grade:
11.7
GPD/Ftr
IF,.
Block: La- Subtliasion:
4 2
Depth to pipe bottom from original grade:
Gravel depth beneath pipe:
South Hills
3.7 Ft.
8 Ft
Township Range:
Section:
Fill added above original grade:
Gravel Length:
0-1 Ft.
63 Ft.
Well: Q New El Upgrade
Gravel width :
Number of lines:
Distance between lines:
3 FL
1
classMcation(Private, A. 8, q.
Total Depth:
casetl to:
Total absorption area:
Pipe Material:
Private
48
1.
48 FL
1,008 FF
ASTM D3034 PVC
Driller
Date Drillatl:
Static Water Level:
Installer
Date Installed
Alpine Drilling
9112/01
0 Ft
Owner
7/24-2612002
YieldPump
Set at:
casing Height Above Ground
TANK
40 GPM
)' Ft.
2 Ft,
SEPARATION DISTANCES
® Septic ❑ Holding ❑ S.T.E.P. ❑ Other:
To
Septic
Absorption
Lift
Holding
lubliciPrivate
Manufacturer
Capaaty:
From
Tank
Field
Station
Tank
Sewer Line
Anchorage Tank
1,000 Gal,
Material:
Number of Compartments:
Well
>100'
>100'
>100'
N/A
>25'
Steel
Two (2)
Surface Water
>1001
>100'
>100'
N/A
LIFT STATION
See:
anu cturer:
Lot Line
>5,
>10'
>5'
NIA
cat.
"Pump mi level at
Pump W level at
High water alarm at:
Foundation
>5'
>10'
>5'
N/A
in,
in.
in.
Pump Make B Model
Eleanoal lnspec ions performed by:
certain Drain
None
Noted
Remak':
House is unoccupied and not completed.
BENCH MARK
Location and Desarblbn:
Garage Slab
Assumed Elevation:
100.0 Ft.
�E' UWkNownl
�
Inspections performed by: MEA
Dates: 1st 7/25/2002
n
+ P'(�•••••••.,�,Qsir`
�rE
27/26/2002(��i
S'f
Development Services Department Approval
s
Conditional Approval
Date:
CE•4381
11,�gfe
(q.
�h;
Reviewed and approved b404V b.
Date: �a
OFFSSt�,`ee
4
ue„. haoa)
t0e�
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT Page 2 of 3
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
Permit Number: SWO10277 PID No. 017-072-11
OLD RABBIT CREEK ROAD
152.96
Well
f
I
' I
I
I
r I
I
IC
w s
IE
Ia
0
CO
Iw
I"
LEGEND
Io d
S1 — Septic Vent
C4 — Clean Out
M1 — Monitor Tube A B
FCO — Foundation Clean Out
TH Test Hole 51 34.5' 45.9'
—
S2 41.4' 46.0'
C3 50.3' 44.7'
C4 110.9 59.8'
M1 58.8' 39.6'
PLAN
I
AS BUILT
I
Three I
SCALE 1' = 50' Bedroom
Home
FCO q I
Alfernote Sife o` I
OFq�� p�. C4 TH1 0 TH2 a s1
I
----
+� 49th �.•ci>:}
.....:.............. ..... ..... — J
•��;MICHAEL E. ....
t5
3.50
..............NEON '
it HILL
•1 f•t, No. CE-4361 •'1. SIDE WAY
Permit Number: SWO10277
Municipality of Anchorage Page 3 of 3
DEVEOPMENT SERVICES DEPARTMENT
4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
RnIshetl
ratle
2" Inwlation
1000 Gallon
Septic Tank
PID No. 017-072-11
No*Groundwater
PROFILE AS -BUILT
No Scale
5.4
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 V Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
Mp://www.danchorage.ak.us
Permit Number: #SW 010277 Date of Issue: 7-30-01 Parcel Identification Number: 017-072-11
Date Started: 9-12-01 Date Completed: 9-13-01 Is well located at approved permit location? ® Yes ❑ No
Legal Description: South Hills Blk 4 Lt 2
Property Owner Name & Address: Kenneth E. Brown
2811 E. 46" Ave
Anchorage, Ak 99510
Borehole Data:
Soil Type, Thickness & Water Strata
Depth (ft)
. From To
Method of Drilling ® air rotary ❑ cable tool
Casing type: steel
stick-up
0 2
Wall Thickness: .025 inches
gravelly cobbly silt w/bldrs
23 31
Diameter: 6 inches Depth: 48 feet
silty water sand & gravel
31 46
Liner Type:
water sand & gravel
46 48
Diameter: inches Depth: feet
Casing stickup above ground: 2 feet
Static water level (from ground level): 0 feet
Pumping level: 48 feet after
2 hours pumping 40 gpm
Recovery Rate:, 40 gpm
Method of Testing: air lift .
Well Intake Opening Type:
® Open End ❑ Open Hole ►�'
❑ Screened Start feet Stopped feet
❑ Perforations Start feet Stopped feet
Grout Type: Bentonite # 8 -..'-Volume: 1 bg
Depth: Start''Q feet .. Stopped + feet
Pump: Intake Depth
Pump size hp Brand Name
Well Disinfected Upon Completion? ® Yes ❑ No
Method of Disinfection: Clorine Tablets
Comments:
Well Driller: Alpine Drilling & Enterprises
P O Boz 110496 -
Anchorage AK 99511
Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property
nutinor nr the wall slrillar ehall nrnvirla a talpll Inrt }n the T1Pnt of 74P*lth Rs 149iman Cs-mAr-pe within r%n have of nmmnipann
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Initial
Permit Number: SW010277
Legal Description: SOUTH HILLS BLK 4 LT 2
Design Engineer: ? 0014 Anderson Engineering
Owner Name: Kenneth E. Brown
Owner Address: 2811 E. 46th Ave
Anchorage , AK 99510 -
Date Issued: Jul 30, 2001
Expiration Date: Jul 30, 2002
Parcel ID: 017-072-11
Site Address:
Lot Size: 52305 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
Disposal Field F✓ Septic Tank ❑ Holding Tank F-� Privy Private Well Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
g-17-0/ 5EE FN6�ILErrz's J9M9-cKFp wjgr,&R WFL.1- 8F1_0047 -10A. 0)97'Fa
g—ib —o/
Received By:
Issued By:
Date: e
Date:
ENGINEERING
ANDERSON,
F
P.O: BOX 240773
ANCHORAGE,£'AK 99524
522-7773-6779 (FAX) ...
MEMORANDUM
DATE: August 16, 2001
TO: Dan Roth ��,, tt �
FROM: Mike Anderson, P.EWV`""'
SUBJECT: Lot 2, Block 4, South Hills Subdivision
Permit No. SWO10277
Proposed Well Location
The owner of the subject lot intends to place the proposed well to serve the new home
at the northwest comer of the lot and not in the middle as originally designed. The new
location is easier to access and, according to the well driller, will provide a greater
volume of water. The placement of the well at this location will not conflict with adjacent
septic systems, as Rabbit Creek is approximately 70' to the north. We hereby request
the permit be amended to allow the new location for the well.
Thank you for your consideration with this modification.
OLD RABBIT CREEK ROAD
Proposed
ell
rt
C w
dP dP ft
O O
CP dp -
Fill Required in This Area
:to Provide 50' Separation = I
Between Absorption Trench • J
and S3opes Greater Than 25$ 111
�
CP
c Alternate Site- -0
°P is Bedroom
O TH1 House .
q3uais uor�ds ski "q7 -Go-rIO
.8 aPTm .£ X buo'I000
SepticGTankn
insulation Required Over
Line Under Driveway
HILLSIDE
WAY
SITE PLAN
SCALE 1" = 30'
Municipality of Anchorage
'GL e41
r • Development Services Department =p
Building Safety Division k< _
4 � n
On -Site Water and Wastewater Program S A E T r
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 017.072.11 Permit Number SW G/0 2 7 Z
Property owner(s) Kenneth E. Brown Day phone 230-7921
Mailing address (1) 2811 East 46th Avenue Anchorage, AK 99510
Mailing address (2) Zip Code
Legal description (Lot, Block & Sub'd.) Lot 2, Block 4, South Hills Subdivision
Legal description (Section, Township & Range)
Lot Size 52,305 SF Acres/Sq.Ft.
THIS APPLICATION IS FOR:
Number of Bedrooms Three
Sewer Only ❑ Well Only ❑
Sewer and Well ® Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
C7 p
Permit Fees: - Waiver Fees:
Date of Payment: b b Date of Payment:
Receipt Number: 794D Receipt Number:
(Rev. 12/00)
ANDERSON�ENGINEERING. •
P.O: BOX 240773
ANCHORAGE, AK 99524
MEMORANDUM
DATE: July 29, 2001
TO: Jim Cross, P.E.
Ukk-
FROM: Mike Anderson, P.E�
SUBJECT: Lot 2, Block 4, South Hills Subdivision
Septic System Design and Permit Application
I have reviewed your comments and revised the septic system design for the subject lot
accordingly. A cross section of the surface of the lot has been developed for the
surface of the lot near the proposed trenches. The lot is fairly flat from the south
property line to 42' north. It then drops 6' in the next 35' and then drops vertically 8'.
The 4:1 slope from 2' above the flow line of the primary trench will not daylight. The 4:1
slope for the alternate trench does. Approximately 100 cubic yards of material will be
required to fill in the area near the vertical drop. This area will be recontoured once the
well is drilled as the vertical drop is a result of the road constructed to provide access
for the well rig. Excavation for the primary absorption trench will result in nearly 60
cubic yards of excess material. The remainder will come from excess material from the
house excavation.
I have also added dimensions to the trenches from the property lines and a dimension
from the house to the septic tank.
Please let me know if additional information is required before the construction permit
can be issued.
. DERSON,'ENGINEERI,NG ,
P..O>BOX'240773
ANCHORAGE,' AK 99524
522-7773 522-6779 :(FAX)
July 13, 2001
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 2, Block 4, South Hills Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 2, Block 4, South Hills Subdivision intends to construct a three-
bedroom home on the lot. We are therefore applying for a permit to construct a new
well and septic system on the lot to serve the new home. The attached Site Plan and
backup documentation identify the location and configuration of the new well and septic
system and the parameters used in the design. Also identified on the plans is the
location of the proposed well along with the test holes. Existing drainage patterns are
shown and will not be altered by the development of the lot. Some grading and filling
will be required on the steep slope north of the new absorption trench to provide a
minimum of 50' separation from a slope greater than 25%.
Two test holes were placed near the location of the new absorption trench. These
holes indicate a dense silty gravel. Percolation tests in the material resulted in a rate
approximating 60 minutes per inch. No groundwater was found during placement of
the test holes and none developed during the monitoring period. We are therefore
proposing to place a deep absorption trench with 8' of gravel beneath the distribution
pipe. The total depth of the trench will be approximately 11'. The distribution pipe will
be placed at 3' below the ground surface. The service line from the septic tank to the
absorption trench will pass under the proposed driveway. The line will be covered with
a minimum of 2" of direct bury insulation.
The ground surface on the lot slopes as shown on the attached Site Plan with steep
grades just north of the new trench. The new absorption trench will be constructed on a
fairly flat surface near the top of the lot in conformance with Municipal requirements and
parallel to ground contours where possible.'
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
Lot 2, Block 4, South Hills
• July 13, 2001
Page Two
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
�
Sincerely, o
i ,fc�ac�. E 041t-�
Michael E. Anderson, P.E.
Attachments
OF�,�
t�T! • S
! A�ICIIAEL E. ANDERSON ,
t �••, CE - 43E1
� i
�CLa •PR0FES'S*\ P
t t V, t ��4
ANDERSON ENGINEERING
P.O. Sox 240773
ANCHORAGE, AK 99524
(907) 522-7773
Cell (907) .441-4000
JOB
SHEET NO.
CALCULATED BY
CHECKED BY_
OF
DATE
DATE
RABBIT 152.96
— .CRE
EK Rood : .96
-10 'EF
132J.23 -•�. a 152.2:
152.95
152.9
6 HIS PROJECT:
=M r
I � I � 01 is6, ��` ` •X
I I i I I I 152.30
I I I I I I
6 'I� j I j ► j
W
N
M
I Well o %
I I
I I I I VACANT
-1533p— � I Well
I
_. _
WA Y.:.......�.r.
.50' g3;s20Q
rrp 3.50
x53.5 s
153.50
i 5 m
N I
I r I IE
I I
7s— — — — 11 Well I I
—�5 L— I I
I I 10• U111 E„�
I
II I •> Morrontj DeeQ� '� '
c I'°
N ;
I n
'CO. IMd .r
1
I I Yrt9si�¢t:%pfotlWorrpntY£Deed
Bk, 60 Y Pg '424'
152.53
253
15
........ � '154, •
. c
I Bk 132 Pg E
ti 5 .�6� ' MIC1�lAE1.::�, .71NDER�ON 4 r� Y • h Y
7 'AREA MAP "a c,r-sf•. ,•�m
•s
1"=100' YY n R xGCt�Epf'�h'••`!1�1a�,'
..
r ..
OLD RABBIT CREEK ROAD
9
®.
Proposed Well
Fill Required in This Area /
."'to Provide 50' Separation
Between" -Absorption Trnch .
and Slo es Greater Th -an -25
to
CP
Alternate Site • • H
(DThree
TH0. 2 • .
dP Bedroom
O THl r- House
gDUaZX U0Tjd-TPff4Vi'�eQ
000 Gallon
Septic Tank
OF , A�tQy Insulation Required Over
,
r
Line Under Driveway
�j.' • :. `� �/ 0 HILLSIDE :.
Tfl~� 0 WAY
E. ANDERSC!
o+
f'. J•,'. CE-4331•'�`"^' SITE
. �, PLAN
r • SC '. I
> ALE 1 n = 30
.11
W
W
O
10
dP
dP
II
,A.
,Is
O
O
CP
dP
Fill Required in This Area /
."'to Provide 50' Separation
Between" -Absorption Trnch .
and Slo es Greater Th -an -25
to
CP
Alternate Site • • H
(DThree
TH0. 2 • .
dP Bedroom
O THl r- House
gDUaZX U0Tjd-TPff4Vi'�eQ
000 Gallon
Septic Tank
OF , A�tQy Insulation Required Over
,
r
Line Under Driveway
�j.' • :. `� �/ 0 HILLSIDE :.
Tfl~� 0 WAY
E. ANDERSC!
o+
f'. J•,'. CE-4331•'�`"^' SITE
. �, PLAN
r • SC '. I
> ALE 1 n = 30
.11
LOT 2, BLOCK 4, SOUTH HILLS SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Three Bedroom Home Deep Trench System
Perc. Rate: 60 MinJlnch 1,000 Gallon Septic Tank
Avg. Application Rate: .45 GPD/SF 8' Drain Field Rock
3 Bedrooms X 150 GPD /.45 GPD/SF = 1,000 SF of Absorption Area
1,000 SF/16 SF/LF = 62.5 LF Trench Length
Therefore: Construct an Absorption Trench 63' in Length by 3' Wide With 8' of Drainfield
Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 3' Below Existing
Ground. Total Depth of Trench to Be 11' from Existing Surface. Mound Over Trench if
Necessary to Provide Minimum Cover of 3'.
i
Natural
216" ' Backfill
6"
91
3,
Geotextile
'Fabric
4" Perforated
PVC (Slots Down)
Drainfield
Rock
TYPICAL DEEP TRENCH SECTION
(NO SCALE) �""%,e v %U%4
Iq
NOTE: Grade Area Over Trench to Drain Away. QEF' • OF A L
Minimum 6 Separation From Bedrock.
Minimum 10' Separation From Lot Line.
Minimum 4' Separation From Groundwater. ; 49?H �%�.
Minimum 100 Separation From Well.
Maintain 50' Separation From Slope >25%. • • �'
MICHAEL E. ANDERSON •:�
�40 Jf••. CE - 4381 v�� a
Municipality of Anchorage ••
Department of Health & Human Services `�a ...•- .• 7
825 L Street, Anchorage, AK 99502-0650 0, �,.MICHAEL E. ANDERSON ,
SOILS LOG - PERCOLATION TEST %r •• CE - 4381 ••.
r
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Silty Gravel
GM
Was Groundwater
Encountered? No S
If Yes, What Depth? L
Depth to Water O
After Monitoring None P
Date: 711101 E
Bottom of
Hole
Perc. Rate: 60 Min./Inch Perc. Hole Diameter: 6"
Test Run Between 7 Ft. and 8 Ft.
Comments: Percolation Cavity Presoaked Prior to Testing.
Performed By: Tim Kimbrouah. I, Michael E. Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 7/12101
Date PerformLwt0(,9�'
SITE PLAN
See Site Plan
Reading
Date Gross
Time
Net
Time
Depth To Net
Water Drop
1
20 -Apr 3:00
.75"
2
3:30
30
1.25" .5"
3
3:31
1
.75"
4
4:01
30
1.25" .5"
5
4:02
.75"
6
4:32
30
1.25" .5"
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Silty Gravel
GM
Was Groundwater
Encountered? No
OF
If Yes, What Depth?
L
Depth to Water
O
After Monitoring None
�
Date: 7/1101
49�*
Municipality of Anchorage
1" .5"
Department of Health & Human Services
0"":
825 L Street, Anchorage, AK 99502-0650
0� ��c.MICHACEE EaANDERSON • `�,
EG
SOILS LOG -PERCOLATION TEST
5:01
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Silty Gravel
GM
Was Groundwater
Encountered? No
S
If Yes, What Depth?
L
Depth to Water
O
After Monitoring None
P
Date: 7/1101
E
Bottom of
Hole
Perc. Rate: 60 MinAnch Perc. Hole Diameter: 6"
Test Run Between 7 Ft. and 8 Ft.
Comments: Percolation Cavity Presoaked Prior to Testing. Same Material as Test Hole No. 1
Performed By: Tim Kimbrouah, I, Michael E. Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 7/12101
tt pROFESS\���a
Date Performe- t t014/20r9�
SITE PLAN
See Site Plan
Reading
Date Gross
Time
Net
Time
Depth To Net
Water Drop
1
20 -Apr 4:00
.5"
2
4:30
30
1" .5"
3
4:31
1
.75"
4
5:01
30
1.25" .5"
5
5:02
.5"
6
5:32
30
1" .5"
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 2, BLOCK 4, SOUTH HILLS SUBDIVISION
GENERAL:
1. The scope of this project includes the procurement and placement of a
new 1,000 -gallon septic tank at the location shown on the site plan.
Work also includes the construction of a new 63' long X 3' wide X 8'
effective depth absorption trench at the location shown. The
distribution line in the trench will be placed at 3' below the existing
ground surface. Total depth of the trench will be 11' below the existing
ground surface. Grading will be required downslope from the
absorption trench to provide a minimum of 50' separation from any
slope greater than 25%. All components of the septic system must be
placed a minimum of 100' from all wells in the area.
2. Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
4. Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
A new 1,000 -gallon septic tank must be procured from an approved
source and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
.. Lot 2, Block 4, South Hills Subdivision
July 13, 2001
Page 2 of 3
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
6. Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trenches to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
Lot 2, Block 4, South Hills Subdivision
July 13, 2001
Page 3 of 3
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as -built of the completed system.
+ Dear Mr. Cross,
This letter is to inform you that I Ken Brown will be doing my own
Excavatiou, Concrete, Masonry, and building of my own personal house,
under the supervision of Anderson Engineering,Faulkenberry&Associates,
Beason Plumbing,and D.B.Masonry my brother.
I have been doing work in AK sense about 1983; I have worked for
major contractors, Matrix for 10 years, and numerous others, I own my own
business O.T.I. license #27815.
I own my own 580 case backhoe and have ran a backhoe from highschool
on.
I have talked to Mike Anderson about doing my own dirt work and informed
him that iam able to operate my own equipment. He will be inspecting my
work from time to time to make sure it is done in accordance with the
Municipality of Anchorage.
hCt44A (IVtt.
10