HomeMy WebLinkAboutSOUTH HILLS BLK 4 LT 2South Hills Blo k 4 Lot 2 #017-072-11 Municipality of Anchorage a 1 Development Services Department Building Safety Division OnSite Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SWO10277 PID Number: 017-072-11 Name: Kenneth E. Brown Wastewater System: ❑✓ New E3 Upgrade Address: 2811 E. 46th Avenue Anchorage, AK 99510 ABSORPTION FIELD Phone: 230-]921 Numberof Bedrooms: 3 V Deep Trench ❑Shallow Trench D Betl ❑ Mound ❑Other LEGAL DESCRIPTION Sal Rating: as Total Depth from original grade: 11.7 GPD/Ftr IF,. Block: La- Subtliasion: 4 2 Depth to pipe bottom from original grade: Gravel depth beneath pipe: South Hills 3.7 Ft. 8 Ft Township Range: Section: Fill added above original grade: Gravel Length: 0-1 Ft. 63 Ft. Well: Q New El Upgrade Gravel width : Number of lines: Distance between lines: 3 FL 1 classMcation(Private, A. 8, q. Total Depth: casetl to: Total absorption area: Pipe Material: Private 48 1. 48 FL 1,008 FF ASTM D3034 PVC Driller Date Drillatl: Static Water Level: Installer Date Installed Alpine Drilling 9112/01 0 Ft Owner 7/24-2612002 YieldPump Set at: casing Height Above Ground TANK 40 GPM )' Ft. 2 Ft, SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding lubliciPrivate Manufacturer Capaaty: From Tank Field Station Tank Sewer Line Anchorage Tank 1,000 Gal, Material: Number of Compartments: Well >100' >100' >100' N/A >25' Steel Two (2) Surface Water >1001 >100' >100' N/A LIFT STATION See: anu cturer: Lot Line >5, >10' >5' NIA cat. "Pump mi level at Pump W level at High water alarm at: Foundation >5' >10' >5' N/A in, in. in. Pump Make B Model Eleanoal lnspec ions performed by: certain Drain None Noted Remak': House is unoccupied and not completed. BENCH MARK Location and Desarblbn: Garage Slab Assumed Elevation: 100.0 Ft. �E' UWkNownl � Inspections performed by: MEA Dates: 1st 7/25/2002 n + P'(�•••••••.,�,Qsir` �rE 27/26/2002(��i S'f Development Services Department Approval s Conditional Approval Date: CE•4381 11,�gfe (q. �h; Reviewed and approved b404V b. Date: �a OFFSSt�,`ee 4 ue„. haoa) t0e� Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT Page 2 of 3 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 Permit Number: SWO10277 PID No. 017-072-11 OLD RABBIT CREEK ROAD 152.96 Well f I ' I I I r I I IC w s IE Ia 0 CO Iw I" LEGEND Io d S1 — Septic Vent C4 — Clean Out M1 — Monitor Tube A B FCO — Foundation Clean Out TH Test Hole 51 34.5' 45.9' — S2 41.4' 46.0' C3 50.3' 44.7' C4 110.9 59.8' M1 58.8' 39.6' PLAN I AS BUILT I Three I SCALE 1' = 50' Bedroom Home FCO q I Alfernote Sife o` I OFq�� p�. C4 TH1 0 TH2 a s1 I ---- +� 49th �.•ci>:} .....:.............. ..... ..... — J •��;MICHAEL E. .... t5 3.50 ..............NEON ' it HILL •1 f•t, No. CE-4361 •'1. SIDE WAY Permit Number: SWO10277 Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report RnIshetl ratle 2" Inwlation 1000 Gallon Septic Tank PID No. 017-072-11 No*Groundwater PROFILE AS -BUILT No Scale 5.4 Mayor Municipality of Anchorage Department of Health and Human Services 825 V Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Mp://www.danchorage.ak.us Permit Number: #SW 010277 Date of Issue: 7-30-01 Parcel Identification Number: 017-072-11 Date Started: 9-12-01 Date Completed: 9-13-01 Is well located at approved permit location? ® Yes ❑ No Legal Description: South Hills Blk 4 Lt 2 Property Owner Name & Address: Kenneth E. Brown 2811 E. 46" Ave Anchorage, Ak 99510 Borehole Data: Soil Type, Thickness & Water Strata Depth (ft) . From To Method of Drilling ® air rotary ❑ cable tool Casing type: steel stick-up 0 2 Wall Thickness: .025 inches gravelly cobbly silt w/bldrs 23 31 Diameter: 6 inches Depth: 48 feet silty water sand & gravel 31 46 Liner Type: water sand & gravel 46 48 Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 0 feet Pumping level: 48 feet after 2 hours pumping 40 gpm Recovery Rate:, 40 gpm Method of Testing: air lift . Well Intake Opening Type: ® Open End ❑ Open Hole ►�' ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: Bentonite # 8 -..'-Volume: 1 bg Depth: Start''Q feet .. Stopped + feet Pump: Intake Depth Pump size hp Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: Clorine Tablets Comments: Well Driller: Alpine Drilling & Enterprises P O Boz 110496 - Anchorage AK 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property nutinor nr the wall slrillar ehall nrnvirla a talpll Inrt }n the T1Pnt of 74P*lth Rs 149iman Cs-mAr-pe within r%n have of nmmnipann MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW010277 Legal Description: SOUTH HILLS BLK 4 LT 2 Design Engineer: ? 0014 Anderson Engineering Owner Name: Kenneth E. Brown Owner Address: 2811 E. 46th Ave Anchorage , AK 99510 - Date Issued: Jul 30, 2001 Expiration Date: Jul 30, 2002 Parcel ID: 017-072-11 Site Address: Lot Size: 52305 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: Disposal Field F✓ Septic Tank ❑ Holding Tank F-� Privy Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. g-17-0/ 5EE FN6�ILErrz's J9M9-cKFp wjgr,&R WFL.1- 8F1_0047 -10A. 0)97'Fa g—ib —o/ Received By: Issued By: Date: e Date: ENGINEERING ANDERSON, F P.O: BOX 240773 ANCHORAGE,£'AK 99524 522-7773-6779 (FAX) ... MEMORANDUM DATE: August 16, 2001 TO: Dan Roth ��,, tt � FROM: Mike Anderson, P.EWV`""' SUBJECT: Lot 2, Block 4, South Hills Subdivision Permit No. SWO10277 Proposed Well Location The owner of the subject lot intends to place the proposed well to serve the new home at the northwest comer of the lot and not in the middle as originally designed. The new location is easier to access and, according to the well driller, will provide a greater volume of water. The placement of the well at this location will not conflict with adjacent septic systems, as Rabbit Creek is approximately 70' to the north. We hereby request the permit be amended to allow the new location for the well. Thank you for your consideration with this modification. OLD RABBIT CREEK ROAD Proposed ell rt C w dP dP ft O O CP dp - Fill Required in This Area :to Provide 50' Separation = I Between Absorption Trench • J and S3opes Greater Than 25$ 111 � CP c Alternate Site- -0 °P is Bedroom O TH1 House . q3uais uor�ds ski "q7 -Go-rIO .8 aPTm .£ X buo'I000 SepticGTankn insulation Required Over Line Under Driveway HILLSIDE WAY SITE PLAN SCALE 1" = 30' Municipality of Anchorage 'GL e41 r • Development Services Department =p Building Safety Division k< _ 4 � n On -Site Water and Wastewater Program S A E T r 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 017.072.11 Permit Number SW G/0 2 7 Z Property owner(s) Kenneth E. Brown Day phone 230-7921 Mailing address (1) 2811 East 46th Avenue Anchorage, AK 99510 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 2, Block 4, South Hills Subdivision Legal description (Section, Township & Range) Lot Size 52,305 SF Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms Three Sewer Only ❑ Well Only ❑ Sewer and Well ® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) C7 p Permit Fees: - Waiver Fees: Date of Payment: b b Date of Payment: Receipt Number: 794D Receipt Number: (Rev. 12/00) ANDERSON�ENGINEERING. • P.O: BOX 240773 ANCHORAGE, AK 99524 MEMORANDUM DATE: July 29, 2001 TO: Jim Cross, P.E. Ukk- FROM: Mike Anderson, P.E� SUBJECT: Lot 2, Block 4, South Hills Subdivision Septic System Design and Permit Application I have reviewed your comments and revised the septic system design for the subject lot accordingly. A cross section of the surface of the lot has been developed for the surface of the lot near the proposed trenches. The lot is fairly flat from the south property line to 42' north. It then drops 6' in the next 35' and then drops vertically 8'. The 4:1 slope from 2' above the flow line of the primary trench will not daylight. The 4:1 slope for the alternate trench does. Approximately 100 cubic yards of material will be required to fill in the area near the vertical drop. This area will be recontoured once the well is drilled as the vertical drop is a result of the road constructed to provide access for the well rig. Excavation for the primary absorption trench will result in nearly 60 cubic yards of excess material. The remainder will come from excess material from the house excavation. I have also added dimensions to the trenches from the property lines and a dimension from the house to the septic tank. Please let me know if additional information is required before the construction permit can be issued. . DERSON,'ENGINEERI,NG , P..O>BOX'240773 ANCHORAGE,' AK 99524 522-7773 522-6779 :(FAX) July 13, 2001 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 2, Block 4, South Hills Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 2, Block 4, South Hills Subdivision intends to construct a three- bedroom home on the lot. We are therefore applying for a permit to construct a new well and septic system on the lot to serve the new home. The attached Site Plan and backup documentation identify the location and configuration of the new well and septic system and the parameters used in the design. Also identified on the plans is the location of the proposed well along with the test holes. Existing drainage patterns are shown and will not be altered by the development of the lot. Some grading and filling will be required on the steep slope north of the new absorption trench to provide a minimum of 50' separation from a slope greater than 25%. Two test holes were placed near the location of the new absorption trench. These holes indicate a dense silty gravel. Percolation tests in the material resulted in a rate approximating 60 minutes per inch. No groundwater was found during placement of the test holes and none developed during the monitoring period. We are therefore proposing to place a deep absorption trench with 8' of gravel beneath the distribution pipe. The total depth of the trench will be approximately 11'. The distribution pipe will be placed at 3' below the ground surface. The service line from the septic tank to the absorption trench will pass under the proposed driveway. The line will be covered with a minimum of 2" of direct bury insulation. The ground surface on the lot slopes as shown on the attached Site Plan with steep grades just north of the new trench. The new absorption trench will be constructed on a fairly flat surface near the top of the lot in conformance with Municipal requirements and parallel to ground contours where possible.' If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. Lot 2, Block 4, South Hills • July 13, 2001 Page Two 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. � Sincerely, o i ,fc�ac�. E 041t-� Michael E. Anderson, P.E. Attachments OF�,� t�T! • S ! A�ICIIAEL E. ANDERSON , t �••, CE - 43E1 � i �CLa •PR0FES'S*\ P t t V, t ��4 ANDERSON ENGINEERING P.O. Sox 240773 ANCHORAGE, AK 99524 (907) 522-7773 Cell (907) .441-4000 JOB SHEET NO. CALCULATED BY CHECKED BY_ OF DATE DATE RABBIT 152.96 — .CRE EK Rood : .96 -10 'EF 132J.23 -•�. a 152.2: 152.95 152.9 6 HIS PROJECT: =M r I � I � 01 is6, ��` ` •X I I i I I I 152.30 I I I I I I 6 'I� j I j ► j W N M I Well o % I I I I I I VACANT -1533p— � I Well I _. _ WA Y.:.......�.r. .50' g3;s20Q rrp 3.50 x53.5 s 153.50 i 5 m N I I r I IE I I 7s— — — — 11 Well I I —�5 L— I I I I 10• U111 E„� I II I •> Morrontj DeeQ� '� ' c I'° N ; I n 'CO. IMd .r 1 I I Yrt9si�¢t:%pfotlWorrpntY£Deed Bk, 60 Y Pg '424' 152.53 253 15 ........ � '154, • . c I Bk 132 Pg E ti 5 .�6� ' MIC1�lAE1.::�, .71NDER�ON 4 r� Y • h Y 7 'AREA MAP "a c,r-sf•. ,•�m •s 1"=100' YY n R xGCt�Epf'�h'••`!1�1a�,' .. r .. OLD RABBIT CREEK ROAD 9 ®. Proposed Well Fill Required in This Area / ."'to Provide 50' Separation Between" -Absorption Trnch . and Slo es Greater Th -an -25 to CP Alternate Site • • H (DThree TH0. 2 • . dP Bedroom O THl r- House gDUaZX U0Tjd-TPff4Vi'�eQ 000 Gallon Septic Tank OF , A�tQy Insulation Required Over , r Line Under Driveway �j.' • :. `� �/ 0 HILLSIDE :. Tfl~� 0 WAY E. ANDERSC! o+ f'. J•,'. CE-4331•'�`"^' SITE . �, PLAN r • SC '. I > ALE 1 n = 30 .11 W W O 10 dP dP II ,A. ,Is O O CP dP Fill Required in This Area / ."'to Provide 50' Separation Between" -Absorption Trnch . and Slo es Greater Th -an -25 to CP Alternate Site • • H (DThree TH0. 2 • . dP Bedroom O THl r- House gDUaZX U0Tjd-TPff4Vi'�eQ 000 Gallon Septic Tank OF , A�tQy Insulation Required Over , r Line Under Driveway �j.' • :. `� �/ 0 HILLSIDE :. Tfl~� 0 WAY E. ANDERSC! o+ f'. J•,'. CE-4331•'�`"^' SITE . �, PLAN r • SC '. I > ALE 1 n = 30 .11 LOT 2, BLOCK 4, SOUTH HILLS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home Deep Trench System Perc. Rate: 60 MinJlnch 1,000 Gallon Septic Tank Avg. Application Rate: .45 GPD/SF 8' Drain Field Rock 3 Bedrooms X 150 GPD /.45 GPD/SF = 1,000 SF of Absorption Area 1,000 SF/16 SF/LF = 62.5 LF Trench Length Therefore: Construct an Absorption Trench 63' in Length by 3' Wide With 8' of Drainfield Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 3' Below Existing Ground. Total Depth of Trench to Be 11' from Existing Surface. Mound Over Trench if Necessary to Provide Minimum Cover of 3'. i Natural 216" ' Backfill 6" 91 3, Geotextile 'Fabric 4" Perforated PVC (Slots Down) Drainfield Rock TYPICAL DEEP TRENCH SECTION (NO SCALE) �""%,e v %U%4 Iq NOTE: Grade Area Over Trench to Drain Away. QEF' • OF A L Minimum 6 Separation From Bedrock. Minimum 10' Separation From Lot Line. Minimum 4' Separation From Groundwater. ; 49?H �%�. Minimum 100 Separation From Well. Maintain 50' Separation From Slope >25%. • • �' MICHAEL E. ANDERSON •:� �40 Jf••. CE - 4381 v�� a Municipality of Anchorage •• Department of Health & Human Services `�a ...•- .• 7 825 L Street, Anchorage, AK 99502-0650 0, �,.MICHAEL E. ANDERSON , SOILS LOG - PERCOLATION TEST %r •• CE - 4381 ••. r 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Silty Gravel GM Was Groundwater Encountered? No S If Yes, What Depth? L Depth to Water O After Monitoring None P Date: 711101 E Bottom of Hole Perc. Rate: 60 Min./Inch Perc. Hole Diameter: 6" Test Run Between 7 Ft. and 8 Ft. Comments: Percolation Cavity Presoaked Prior to Testing. Performed By: Tim Kimbrouah. I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 7/12101 Date PerformLwt0(,9�' SITE PLAN See Site Plan Reading Date Gross Time Net Time Depth To Net Water Drop 1 20 -Apr 3:00 .75" 2 3:30 30 1.25" .5" 3 3:31 1 .75" 4 4:01 30 1.25" .5" 5 4:02 .75" 6 4:32 30 1.25" .5" 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Silty Gravel GM Was Groundwater Encountered? No OF If Yes, What Depth? L Depth to Water O After Monitoring None � Date: 7/1101 49�* Municipality of Anchorage 1" .5" Department of Health & Human Services 0"": 825 L Street, Anchorage, AK 99502-0650 0� ��c.MICHACEE EaANDERSON • `�, EG SOILS LOG -PERCOLATION TEST 5:01 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Silty Gravel GM Was Groundwater Encountered? No S If Yes, What Depth? L Depth to Water O After Monitoring None P Date: 7/1101 E Bottom of Hole Perc. Rate: 60 MinAnch Perc. Hole Diameter: 6" Test Run Between 7 Ft. and 8 Ft. Comments: Percolation Cavity Presoaked Prior to Testing. Same Material as Test Hole No. 1 Performed By: Tim Kimbrouah, I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 7/12101 tt pROFESS\���a Date Performe- t t014/20r9� SITE PLAN See Site Plan Reading Date Gross Time Net Time Depth To Net Water Drop 1 20 -Apr 4:00 .5" 2 4:30 30 1" .5" 3 4:31 1 .75" 4 5:01 30 1.25" .5" 5 5:02 .5" 6 5:32 30 1" .5" ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 2, BLOCK 4, SOUTH HILLS SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,000 -gallon septic tank at the location shown on the site plan. Work also includes the construction of a new 63' long X 3' wide X 8' effective depth absorption trench at the location shown. The distribution line in the trench will be placed at 3' below the existing ground surface. Total depth of the trench will be 11' below the existing ground surface. Grading will be required downslope from the absorption trench to provide a minimum of 50' separation from any slope greater than 25%. All components of the septic system must be placed a minimum of 100' from all wells in the area. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,000 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. .. Lot 2, Block 4, South Hills Subdivision July 13, 2001 Page 2 of 3 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). Lot 2, Block 4, South Hills Subdivision July 13, 2001 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. + Dear Mr. Cross, This letter is to inform you that I Ken Brown will be doing my own Excavatiou, Concrete, Masonry, and building of my own personal house, under the supervision of Anderson Engineering,Faulkenberry&Associates, Beason Plumbing,and D.B.Masonry my brother. I have been doing work in AK sense about 1983; I have worked for major contractors, Matrix for 10 years, and numerous others, I own my own business O.T.I. license #27815. I own my own 580 case backhoe and have ran a backhoe from highschool on. I have talked to Mike Anderson about doing my own dirt work and informed him that iam able to operate my own equipment. He will be inspecting my work from time to time to make sure it is done in accordance with the Municipality of Anchorage. hCt44A (IVtt. 10