Loading...
HomeMy WebLinkAboutMUIRWOOD PARK BLK 4 LT 4Muirwood P'ark Block 4 Lot 4 #011-422-81 Certificate of On -Site Systems Approval Parcel I.D. 011-422-81 Legal description Muirwood Park Block 4 Lot 4 Site address 7453 Park West Circle, Anchorage, Ak Current property owner(s) Novakovich Expiration Date: 9-6-2023 X The On-site system(s) is/are approved for 5 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: By: Original Certificate Date: 9-22-22 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MMMUFUTY OF ° HC HORAGEE 'g � Development Services Department t Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 011-422-81 Complete legal description MUirwood Park, Block 4 Lot 4 Location (site address) 7453 Park West Circle, Anchorage, AK 99502 Current property owner(s) Stephen & Lauren Novakovich Day phone 2. ON-SITE SYSTEMS SIZED FOR 5 BEDROOMS 3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑■ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: [M-1 Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ■❑ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 18 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ 55b Date of Payment 911 la a C)"A' COSA # DSC, ZZ-l�(�l Waiver Fee $ Date of Payment Waiver # COSA Application—June 2022 Legal Description: Muirwood Park, Block 4 Lot 4 Parcel ID: 011-422-81 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA I log is filed with Onsite (or attached) Date drilled _ Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. comments Property is served by public water. B. TANK DATA Measured operating fluid level in septic tank 48" Date of pumping 9/20/22* ❑ Required maintenance completed, if AWWTS comments: Around the Clock Pumping* D. ABSORPTION FIELD DATA Which system tested (date installed) 6/2/04 ❑ ALL standpipes present per record drawing Total measured depth from grade 12.6 ft (max) Measured depth to pipe invert from grade 4.8 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. ❑ Monitor tubes go to bottom of effective. If not, state depth into effective 7.8 ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced N/A gallons N/A date Any rejuvenation treatment (past 12 months) N/A If yes, enter date Comments/Deficiencies: COSA Checklist June 2022 Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arser �_ ug/L ❑ Arsenic less than MRL (ND) Collected by Date C. LIFT STATION maintenance completed Age of lift station _ years Lift station material Comments: Adequacy test date 9/6/22 Results ❑ Pass Fluid depth prior to test 0 in Water added 968 gal New fluid depth 12 in Elapsed time 1440 min Final fluid depth 0 in Absorption rate ' 750 gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 96 Effective depth used 0 in Effective depth remaining 96 in in E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) ank/Lift Station on Lot > 100' Q Community Sewer Manhole/Cleanout > 100' ❑Yes if No ft ❑ Yes if No ft Neighboring Tank > 100' if No ft Private Sewer/Septic Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No Holding an > 100' ❑ Yes if No ft Neighboring Absorption Fields > 100' Animal Con nt > 50' El if No ft ❑ Yes if No ft if No ft Private Wells > 100' Manure/Animal Excreta Storage Community Sewer Main > 75' ❑ Yes if No ft _ ❑ Yes I �� ft ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' Q Yes if No ft Surface Water > 100' Fil Yes if No _ Tank to Property Line > 5' m❑ Yes if No ft Wells on Adjacent Lots: Field to Property Line > 10' Fil Yes if No ft Private Wells > 100' FN_1 Yes if No Water Main > 10' n Yes if No ft Community Wells > 200' n Yes if No Water Service Line > 10' Yes if No ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS ft ft ft G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Forge Engineering Engineer's Printed Name Benjamin Schiller, P. E. COSA Checklist—June 2022 Phone (907) 522-7773 Date / W .. ... �� • r Benjarr,'Schiller ' CE 12592 ��PROFESSION ..�, Municipality of Anchorage Page 1 of 3 Development Services Department On-Site Water and Wastewater Program 4700 South Sragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 wvwv. cLanchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW030206 PID Number: 011-422-81 Crown Pointe, lnc. WastewaterSystem: New Address: P.O. Box 112313 Anch., AK 99511 ABSORPTION FIELD 345-6277 Five (5) Deep Trench LEGAL DESCRIPTION soi, Rating: lo~al Depth from Original grade= .9 ~o/~ 10 ~. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath p~pe: 11 Autumn Ridge 2 ~t. 8 ,t. Township: Range: SecUon: Fill added above odginal grade: Gravel Length: 2'3 Ft, 53 ~t. Well: A~U Gravel w~dth: Number of ~ines: [ Distance between lines: 3-5 ~. 1 Classifi~ on (P [vate, A, B, C): mTotal Depth: Cased to: Tota~ absorption area: Pipe Material: 848 F¢ ASTM 3034 PVC Dr/ilar: Date Ddlled: Static Water Level: Instal/er; Date Instsrled; a Sanders & Sanders 6/2-4/2004 Yield:GPM ,,J P.mp Set at:Ft, j Casing I ;eight AbOVeFt.*,o..~: TANK SEPA~TION DISTANCES ~ Septic ~ Holding ~ S.T.E.P. ~ Other: T~To Septic Absorption LiE Holding ~ub[ic/Pdvate iManufacturer: Capacity in GallJns: F~om % Tank Field Station Tank Sewer Line Anchorage Tank 1,500 w~, N/A N/A N/A N/A N/A Steel Two (2) s~.w~, >100' >100' N/A N/A ~/ LIFT STATION- NONE ON LOT Lot Une >5' >10' N/A N/A Oa~. 'ou.dation >5' >10' N/A N/A //~~ 'r~umP OW' level "b "~ump o~' ,owl ,t:~ m Hig. w~ter amarm a,: c..~m ~,~ None Noted Pump Make & Modem i Eme~ricaJ inspections performed by: BENCH MARK Back Door Thmshhold Southeast Corner 100,0 Ft. Engineer's Stamp Inspections peRormed by: A. Hernia Dates: 1st 612104 2nd 614104 Depa~ment o~ealth ~nd Human Se~ices approval Reviewed and approved by/ ~, ~.l~ ~ ~_~Date: ~/~/~ ~- z o~ o ~ oo , , Municipality Of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: SW030206 PID No. 011-422-81 1,500 Go, t~on Septic Tc~nk 94,9 99,3 Dr'cdn¢ie[d Rock 86,7~ 3~' (Trench Length) 80,0 % 94,9 PROFILE AS-BUILT Scale: 1"= 10' MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Jun 20, 2003 Expiration Date: Jun 19, 2004 Permit Number: SW030206 Legal Description~GcTP'~i~ I~{ Design Engineer: 0014 Anderson Engineering Owner Name: Crown Pointe, Inc. Owner Address: PO Box 112313 Anchorage, AK 99511- Parcel ID: 01 i-422-81 Site Address: 7453 Park West CirCle Lot Size: 40111 SQ. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance With: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsudace soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Parcel I.D. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and WasteWater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www. cLanchorage.ak.us (907) 343-7904 ON-SITE SEWERNVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Permit Number SW 0 ~0 2 0 ~ Property owner(s) Crown Fointe: Inc, Day phone 34..6-.6277 Mailing address (1) P.O. Box 112313 Anchorage_ Ar. 99511 Mailing address (2) ~ q~, "~ P -C~ I(__. ~,A_)O .~'- ~.~i Y'-C~l(LTip COde Legal description (Lot, Block & Sub'd.) Lot 4_ 15lock 4. Muirwood Far~ Sub41ivi.~ion Legal description (Section, Township & Range) Lot Size ~Oi l/ ~ THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Acres/Sq. Ft. Number of Bedrooms Fiw (5) [] Well Only [] [] Water Storage [] [] Jacuzzi [] [] Water Softening Unit [] I certify that the above information is correct. I further certify that this application is being made for a Single FamilY Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: (Rev. 12YO0) Waiver Fees: Date of Payment: Receipt Number:. June 16, 2003 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Su~e~: Lot 4, Block 4, Muirwood Park Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 4, Block 4, Muirwood Park Subdivision intends to construct a new five-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the home. The lot is served by the Municipal water system. The attached Site Plan and backup docUmentatiOn identify the location and configuration of the new septic system and alternate site and the parameters used in the design. Also identified on the plans are the location of the water service line, test holes and the septic systems on the surrounding lots. Drainage arrows and spot elevations are shown indicating the current drainage patterns. The drainage patterns will be maintained after construction. The test holes placed near the location of the proposed absorption trench and alternate site indicated clean sand with some gravel and varying amounts of silt and percolation rates approximating 2 to 27 minutes per inch. We have averaged the percolation rates and are using an application factor of .9 gallons per day per Square foot for the absorp!!on trench. No groUndwater was found during placement Of the test holes and none was noted during the monitoring period. We are therefore proposing to place a 1,500-gallon septic tank and a 53' long x 3' wide x 8' effective depth absorption trench. The distribution pipe will be placed 2' below the existing surface and the total depth will be 10' to. Sufficient fill will be placed over the septic tank and absorption trenCh to prevent freezing. The ground surface on the lot slopes as shown on the site plan from east to west at Lot 4, Block 4, Muirwood Park June 16, 2003 Page Two varying slOpes. The absorption trench will be constructed at the front of the lot parallel with the slope as much as possible in conformance with Municipal requirements. All components of the new septic system will be constructed a minimum of 100' from any surface water and 10' from the water service line on this and adjacent lots. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments SCALE 1" = 100' Z 49th VACANT This Project ¸60 Z O0 O-J ;7 Ill I LOT 4, BLOCK 4, MUIRWOOD PARK SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom Home Deep Trench System Perc. Rate: 1.7-27 MinJInch 1,500 Gallon Septic Tank Application Rate: .9 GPD/SF (Avg.) 8' Drainfield Rock 750 GPD/.9 GPD/SF (Application Rate) = 833.3 SF Absorption Area 833.3 SF/16 SF/LF = 52.08 LF Trench Length THEREFORE: Construct a 53' Long x 3' VVide x 8' Effective Depth Absorption Trench. FI,o,w Line Elevation in Trench to be 2' BelOW Odginal Ground SUrface. TOtal Depth to be 10 Below Existing Ground. Maintain 10' separation FrOm water service Lii~e On Lot. Place ~'rOf Dire_ct Bu.ry Ins,u, lat, io~n and_2' of ~Fill ,O. ve_r Absorption Trench or Prov de Minimum 3' Of Cover to event I-reez rig. ,~ or ~;over uver ~eptic lank. Natural Backfill Geotextile 6" 4" Perforated Holes Down) ~ock TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Are,a, Over Trench to Drain Away. Minimum 6 Separati°n Fr°m Bedr0ck' Minimum 4' Separation From Groundwater. Minimum 10' Separation From VVater SerVice Line. Minimum 100' Separation From Surface VVater or Streams. Municipalit)' of Anchorage Development Services Department/On-Site Water and Wastewater Program 4700 South Bragaw Street, Anchorage, AK 99516-6650 SOILS LOG - PERCOLATION TEST Performed For: White Raven Development Legal Description: Lot 4. Kincaid Park Subdivision 1 11 12 13 14 15 16 17 18 19 8 OG/OL SM 15%-20% Silt GM/SM SLOPE North South No Was Groundwater Encountered? If Yes, What Depth? Depth to Water After Monitoring Date: GP/SP/SW None 2/28/02 3/4%1 ,, Cobbles BoSom of Hole Date Performed: 1/23/02 SITE PLAN S L O P E Reading Date Gross Net Depth To Net Time Time Water Drop 23-Jan 2:48 9,13" 3:03 15 9.75" .63" 3:05 9.25" 3:20 15 9.81" .56" 3:22 9.25" 3:37 15 9.81" .56" 3:38 9.19" 3:53 15 9.81" .63" Perc. Rate: 27 Min./inch Perc. Hale Diameter: 7" Test Run Between 4 Ft. and 5 Ft. Comr:nents: Test.Cavity was PreSoaked Prior to Test. Performed Byi Alan Harala. I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 3/2102 Municipality of Anchorage Development Services Department/On-Site Water and Wastewater Program 4700 South Bragaw Street, Anchorage, AK 99516-6650 SOILS LOG - PERCOLATION TEST Performed For: White Raven Development Legal Description: Lot 4~ Kincaid Park Subdivision OG/OL TESTHOLE NO. t3A SM 15%-20% Silt GM/SM SLOPE North South Date Performed: 1/23/02 SITE PLAN 1I 11 12 13 14 15 16 17 18 19 GP/SP/SW 3/4"-1" Cobbles Bottom of Hole Was Groundwater Encountered? No S If Yes; What Depth? L Depth to Water O After Monitoring None P Date: 2/28/02 E Reading Date Gross Net Depth To Net Time Time Water Drop 23-Jan 3:10 7.5" 3:20 10 13.5" 6" 3:23 7.5" 3:33 10 13.38" 5.88" 3:34 7.5" 3:44 10 13.38" 5.81" Perc. Rate: 1.7 Min./Inch Test Run Between 7 Ft. and 8 Ft. Comments: Prior to Test. Performed By: Alan Harala, I';~ ~!~hael E. Anderson Certify That This Test Was In Accordance With All State andi~'~i'ciPal Guidelines In Effect On This Date: Municipality of Anchorage Development Services Department/On-Site Water and Wastewater Program 4700 South Bragaw Street, Anchorage; AK 99516-6650 SOILS LOG - PERCOLATION TEST Performed For: White Raven Development Legal Description: Lot 4. Kincaid Park Subdivision SLOPE sM 20% Silt SM/SP North South Date Performed: 1/22/02 SITE PLAN 1 11 Was Groundwater Encountered? No If Yes, What Depth? Depth to Water After Monitoring None Date: 2/28/02 S L O P E 12 13 14 15 16 17 18 19 3/4"-1" Cobbies 49~h }ttom of Reading Date [Gross Net Depth To Net Time Time Water Drop 23-Jan 1:52 8.5" 2:02 10 14.25" 5.75" 2:04 8.5" 2:14 10 14.5" 6" 2:15.' 8.5" 2:25~: 10 14.44" 5.94" '2:30~ 8.5" ' 2:40'.'~. 10 14.5" 6" With All State and MtJ~jcipal Guidelines In · :,,:;:%"':L:;~.'~'. Perc. Rate: 2 Min. 8" ' was Presoaked Prior to Test. ',',, ,,, s Perf6'rr~J 3~2~02 ' :' ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SpECiFICATiONS SUBJECT: LOT 4, BLOCK 4, MUIRWOOD PARK SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,500-gallon septic tank at the location shown on the site plan. Work also includes the construction of a new absorPtion trench 53' tong by 3' wide by 8' effective depth also at the lOCation Shown on the Site Plan. The total depth of the trench will be 10' below existing ground and the distribution pipe will be placed at 2' below the surface. All components of the new absorption trench and septic tank must be constructed a minimum of 100' from any surface water and 10' from the water service line on this and adjacent lots. A minimum of 4' of cover is required over the septic tank and 3' over the absorption trench. In lieu of cover 2" of direct bury insulatiOn and 2' of cover may be placed. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responSible for Obtaining all underground utility locates and for the layout of the septic system and verification of the locati°n of all lOt lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from Soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their OWn syStems must receive prior approval from D.H.HiS. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,500-gallon septic tank must be procured from a certified septic tank manufacturer if the exiSting tank is found to be defective. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot4, Block 4, Muirwood Park June 16, 2003 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tankl 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed withOut 4' of cover shall have a minimum of 2" of direct burial insulatiOn. A foundation cleanout shall be inStalled one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be cOnstructed to the dimensions shown on the design. The bottom of the trench shall be Within 2,,of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock shoUld then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall verifY the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' frOm any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. A minimum 2' of accepting soil is required below the drainfleld rock for a 5' wide trench. Contractor shall verifY this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: Lot 4, Block 4, Muirwood Park JUne 16, 2003 Page 3 of 3 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 Or H~D~P.E. (Perfo~atedl bu! not SOlid) and ASTM D2662 or A.B.S. (perforated and sOlid)i 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be tiffed with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextiie fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in Place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-bUilt of the cOmPleted system. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 E!more Road P.O. Box 196650 Anchorage, AK 99519-6650 w"vcw.m uni.org/onsite , (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEI"'IS APPROVAL FOR A SINGLE FAHILY DWELLING O Parcel I.D. 011-422-81 1. GENERAL INFORMATION COSA# ~-~ /I Expiration Date: ~"~ '~ Complete legal description MUIRWOOD PARK; BLOCK 4, LOT 4 Location (site address) 745.3 PARK WEST CIRCLE *ANCHORAGE, AK Current Property owner(s) CAREY MILL Day phone C/O AGENT Mailing address 4100 CARAVELLE DRIVE *ANCHORAGE, AK 99502 Lending agency Day phone Mailing address ReaLEstate Agent Mailing address GORDON SLOANE W/ REMAX Day phone 244-.3581 110 W. 58TH AVE. SUITE 100 *ANCHORAGE, AK 9950.3 Unless Otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 5 3, TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well [] Individual On-site [] Individual Water Storage [] Individual Holding tank [] Community Class Well [] Community On-site [] Public Water System [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water Supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4, STATEMENT OF !NSPECT~ON BY ENGINEER As certified by my sea/affixed hereto and as of the validation date shown below, ! verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows thst the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I furt,her veri~, that based on the infom;ation obtained f'om the Municipality of Anchorage Nes and from ,my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Phone Date 337-6179 Engineer's Comments': In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE ~ Approved for ~ bedrooms. Disapproved, Conditional approval for bedrooms, with the following stipulations: ON, SITE ". ,_ : WATERAND : V '.ASTEWATER . ..., ". ,-, .' PROuRAM . .-. Attachments: COSA Checklist Septic System Advisory Well Flow Advisory (Rev. 11105) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: ~ - ~'''''- // Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: MUIRWOOD PARK; BLOCK 4, LOT 4 Parcel ID: 011-422-81 A. WELL DATA PUBLIC WATER Well type __ If A, B, or C provide PWSID# ~ Well Log (Y/N) Date completed Sanitary seal (Y/N). Wires properly protected (Y/N)_.--/ Total depth ft. Cased to _ _ft. . Casin h Date of test FROM WELL LOG ~ ~CTION Static water level ft. ~ ft. Well production · _.-.-'""'~ g.p.m, g.p.m. WATER SAMPLE R~S~~~. Coliform / colonies/100 mi. Nitrate mg./L. Collected by: ~ ug./L. Date of sample: B. SEPTIC/HOLDING TANK DATA Tank TyPe/Material SEPTIC/STEEL Date installed 6/2-4/04 Tanksize 1500 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping 10/15/10 Pumper. ALASKA SEWER &: DRAIN ABSORPTION FIELD DATA Date installed 6/2-4/0,* Length 53 ft. Total depth .12.91 ft. ~*BELOW EXISTING GRADEI Soil rating (g.p.d./ft2o~ 0.9 System type DEEP TRENCH Width 3-5 ft. Gravel below pipe 8 ft. Eft. absorption area 848 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 7/29/1 1 Results (Pass/Fail) PASS Fluid depth in absorption field before test DRY in. Water added 1090gal. Elapsed Time: 0 min. Final fluid depth DRY in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN For 5 bedrooms New depth DRY in. 75O+ g.p.d. If yes, give date D. LIFT STATION Date installed "Pump on" level at in. ~ ~ Cycles tested. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Size in gallons Manhole/Access (Y~.~.) J "Pump off" leve_La~. High water alarm level at Meets alarm & circuit requirements? PUBLIC WATER in. On adjacent lots Absorption field on lot On adjacent lots .--.- Public sewer main ~nhole/cleanout Sewer/septic service line ~ ~ Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field Water main 10'+ Water service line. '10'+ Surface water. 5'+ 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation. 10'+ Water service line '10'+ Surface water 100'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS *PER MIKE ANDERSON, P.E. INSPECTION REPORT Water main 10'+ Driveway, parking/vehicle storage ' 10'+ G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date ~/2'/II COSA Fee $ L./ Date of Payment Receipt Number (Rev. 11105) Waiver Fee $ Date of Payment Receipt Number / C ~0 ~C 0 Z 4t4SKA.~sEWE_R&24 HOUR EMERGENCYSERVICE /J~ ~ ~ ~. ., ,. ; ~.~ ---~ --%,.~ ',,.~ PO Box 221914 · Anchorage, AK 99522-1914 o Office 248-9551 - Fax 248-95S9 YOUR PROFESSIONAL SEWER & DRAXN CLEA~NI~G SERVICE LICENSED L,L,C. INSURED Date Customer Name Power Snake Steam Thawing Hydro Jet Cleaning Sewer Line Camera Service Call Septic Pumping Extra Man Parts/Tax TOTAL :.~-~ '->' ':f ~- #46180 [] Camera Inspection [] Install Clean Out [] Hydro-Jetting [] Vacuum Truck [] Steam Thawing [] Excavation [] Install New Toilet PO# ~\/: Technician v:, ' : ': .... ,-No Warranty. Customer na r NOT RESPONSIBLE FOR CR'~KED'~R'BRO~N PORCE~IN FIXTURES OR LOST OR BROKEN CABLES IN DRAIN LINES. CUSTOMER AGREES TO PAY FOR DAMAGED~ BROKEN CABLES, JET HOSES ETC. DUE TO FAULTY PLUMBING, AS WELL AS ANY AND ALL OTHER FEES INCURRED ATTHE TIME OF SERVICE. There will be a $30.00 charge on all NSF checks. A collection f~ of 40% will be added if sent to collections. PAYMENT DUE ON RECEIPT Address 7453 Park West Circ. Borrower Novakovich Appraisal Services Company Uniform Residential Appraisal Report City Anchore.qe Owner of Public Record Mills File No. F2156 Case No. State Ak ZipCode 99502-1891 County M.O.A. Mulrwood Park S/D Aasesaofs Pamel# 0114228100001 Tax Year 2011 R.E, Taxes 300e Sand Lake Area Map Reference SW2123 Census Tract PUD HOA $ 145 0023.01 Refinance Transaction Lender/Client Alaska USA Mortgage Co. Address P.O. Box196850~ Anchora!]e~ Alaska 99519-6850 ~ offered for sale or has it been offered for sale in the twelve months pdor to the effective date of this , under contract for the oct within the last t'#elve months. No other transfer found did not snalyze the coned for sale for the subject purdlase transaction. Explain the results of the analysis of the contract for sale or why the analysis was not Data of Contract 06/2011 Isthe ~sellerthe , Assess/Mis Is there any financial assistance (loan charges, sale concessions, gift or downpayment assistance, etc.) to be paid by any par~ on behalf of the bon'ower? he ~tal dollar amount and describe the items to be paid. None Found. It is noted that seller ag raes to allow buyer early occupancy w/ earnest money of $15~000 to become non-refundable & released to seller upon buyer's occupancy. Early occupancy pro-rated for June ~ 08/'1/2011. ect's nbrd, is currentt relative balance. Dimensions Irre,qular (No Survey Supplied) Area 40~111 +-sf Shape Irreg. View Ave Classification R-lA ~ residential use describe. Nons 0200050740D FEMA Map Date 09/25/2009 describe. ~ adverse site conditions or external factors {easements, encroachments, environmental conditions, land uses, etc.)? ~1 Yes ~] No If Yes, describe. ect site is rollin w/some lawn & landscape front to rear and is partly . fenced. No survey of any kind submitted for appraiser's review. Typical easements are assumed. Public Private ~ of Stories 2 Foundation Walls Cc/G Extarior Walls WdBv/G Walls Sr/G Basement Area Ronf Surface Cs/G Trim/Finish Wd/G BasementFinish 87% Alum/Gd Bath F~3or Comp/Cb'Ave 2SCustom Vc/A Ct/G Year Built 2004 Storm Sash/Insulated Yes/G None 4 Settlement Screens Yes/G # of Cars 3 Attic None Amenities Stairs Fuel Gas Fence # of Cars 3+ Scurde Porch Ce # of Cara Heated Other Other CcPatioRw Finished area above grade contains: 11 Rooms 4 Bedrooms 4.0 Bath(s) 3~959 Square Feet of Gross Livin,q Area Above Grade Additional feature4 Dascdhe the condition of the External. baseme~ and is a custom des~ned & buiEtwo sty. Insp. noted as ave+togood. No Functional. No descdbe describe Freddie Mac Form 70 March 2005 Fannie Mae Form 1004 March 2005 Produced by CtickFORMS Software 800-622-8727 Page 2 of 25 Mm _cipality of A_nchorage Development Se rvices Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D.l~11-422-81 1. GENERAL INFORMATION Complete legal description Lot 4, Block 4, Muirwood Park Subdivision Locatior ¢,site address or directionsi 7453 Park West Oircle HAA# 0q 0qSS Expiration Date: V /- - Current Property owner(s) Crown Pointe, Inc. Day phone 345-6277 Mailing address P.O. Box 112313 Anchorafie, AK 99511 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unlees otherwise requested, HAA will be held by DSD for pickup. 2. NUIVIBER OF BEDROOMS: Five (5) TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Public Water System Well TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] [] Individual Holding tank [] [] Community On-site [] [] Public Sewer [] The Municipality of Anchorage Develoament Services Department (DSD) tssues Certificates of Health Authority Approval (HAA) based only upon the reeresentations given in paragraph 5 by an independent professiona: civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served ay a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by.a private or Class C well and may be reissuec with new water samale results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for One year for ~roperties served by Class A or B wells or s oublic water system. The Municipality of Anchorage is not resoonsible for errors or omissions in the r)rofessional engineer's work. 4. STATEf~ENT OF INSPECTION BY ENGINEER As certified by my seat affixed hereto one as of the validation date shown below, I verify that my investigation based on 3rocedures outlined in the Health Authority Approvat Guidelines for this aootication, shows that the on- site water supply and/or wastewater disposal system is(are} safe, functional and adequate for ~ne number of bedrooms and type of structure indicated herein. I further verify that based on the ~nformation obtained from the Municieaiity of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all aoo[icable Municipal and State codes ordinances and regulations :n effect at the time of installabon. Name of Firm Anderson Enaineerinq Address P.O. Box 2407'73 Anchorage, AK 99524 Engineer's Printed Name Michael E, Andersen, P.E. DSD SIGNATURE Approved for ~ bedrooms. DisapBroved. Conditional approval for Phone 522-7773 Date bedrooms, witch '(he following stipulations: By: Additional Comments Attachments: HAA Checklist Septic System Advisory . Welt Flow Advisory Maintenance Agreements Supplemental Eng'neer s Report Other um Dtion field >5' . SUrf~cewate~ ~100" ~ystems are in guidelines in effect on this Waiver Fee $ Date of Payment · ;~: ~.~.~ Receipt Number