HomeMy WebLinkAboutEAGLE CREST #1 TR B LT 19Eagle Crest #1 Tract Im Lot 19 #050-292-06 Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: SW020412 PID Number: 050-292-06 ❑ New ❑Upgrade Name: Stuart McKenzie ABSORPTION FIELD ❑✓ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 18939 Second Street Eagle River, AK 99577 ❑ Other Phone Number of Bedrooms Soil Rating , . Total depth from original grade 4 •8 GPD/SF 8.8-9 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 6.8-7 Ft. Gravel depth beneath pipe 4.0 Ft. Subdivision Block Lot Eagle Crest No. 1 B 19 Fill added above original grade 0-.5 Ft. Gravel length 98 Ft. Township Range Section Gravel width 5Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 980 Ft2 Two 8-9 Ft. Well NA NA NA NA >25' TANK p Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1 1,250Gal. Surface Water >100' >100' >100' >100' Material Number of compartments Lot Line >5' 1' N/A N/A Steel Two NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Lot Served by AWWU Water System. Pump on level at in. Pump off level at in. High water alarm at in. See Lot Line Waiver. System was installed on May 25, 2003. No inspections Pump make and model Electrical Inspections performed by were completed during construction. Installer PIPE MATERIAL House to tank D3034Tank to D3034 drainfield Everett Caulkins Drainfield HDPE CO/MT D3034 Inspector MEA - Verify Dimensions of System BENCH MARK (Assumed elevation) 100.Oft Inspection 1st 6/12/15 dates: 2"d 6/13/15 Location and description 3rd 6/14/15 4'h Bottom Step Front Entrance. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp OF 4 ��•` Conditional Approval: Date _ ,... :...,G �d1 � . A � ; AV �j; •, 0 I *.' Ash' 9 TH . *0 josam ...r re . ........ .....:. MICHAEL E. ANDERSON CE - 4381 � Approved ;' pp Date® Inspection Report -1-1-12/110c Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 Permit No.: SW020412 On -Site Wastewater Disposal System or Well Inspection Report 0 0 L6 co in v co 0 o Z ALTERNATE SITE: Advantex Treatment System with 10' long x 3' Wide x 8' Effective Depth Absorption Trench. Application Rate 5 GPD/SF. 49th W ....... r......jJ... �.., �'. .......:1 MICHAEL E. ANDERSON f No, CE -4381 ��♦♦1,sfROF _ SSIi&ii EAGLE CREST NO. 1 TRACT B, LCT 19 N 89 58'W 132.00 10' UTILITY EASEMENT ----------------------------------------------------------------------- I A I B I C S2 20.1' 39.4' C4 31.2' 51.1- 05 25.4' 11.5' M1 21.7' 8.7' M2 30.4' 52.1' C6 41.3' 64.2' M3 38.8' 27.8' C8 38.5' 26.1' Four Bedroom Home 'C" e, J i Cn Q� ®rH1 Alternate Site N 89 58'W 132.00 a C4 eH2 ;7 M2 c7 -------- ------------- C6 Page 2 of 3 PID No. 050-292-06 SECOND STREET LEGEND SV — Septic Vent CO — Clean Out MT — Monitor Tube M I n A I A f-' T1 I I T I T TH — Test Hole SCALE 1' = 30' Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SW020412 Page 3 of 3 PID No. 050-292-06 00 M t 75 N 2 47' (Trench Length) )C9 PROFILE No Scale 51' (Trench Length) AS -BUILT 95.2 95.0 v �J; r 49th :`........j` .o P ... ...................... MICHAEL E. ANDERSON No, CE -4381 =moo 1� 00%FESS �. EAGLE CREST SUBDIVISION NO. 1 LOT 19, TRACT B DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home 5' Wide Trench System Perc. Rate: 15 Min./Inch 1,250 Gallon Septic Tank Application Rate: .8 GPD/SF 4' Drainfield Rock 4 Bedrooms * 150 GPD/Bedroom = 600 SF Absorption Area 600 SF/.8 GPD/SF/5 SF (Width) *.5 (Red. Factor)= 56.25 LF Trench Length THEREFORE: Construct a 57' Long x 5' Wide x 4' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be 8' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over Septic Tank. 5' TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. ■. . Minimum 4' Separation From Groundwater. 2� Minimum 100' Separation From Private Wells in the Area. Jg Minimum 100' Separation From Surface Water or Streams. sod = MICHAEL E. ANDERSON �• No. CE -0381 T ' 46 _°ROFESSM�Pi Z P.O. Box 196650 e 4700 Elmore Road Anchorage, Alaska 99519-6650 e (907) 343-7904 e Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Section hien! 1)cp;vtment *** / * * * * Waiver#: OSV151056 COSA#: OSC151056 Permit#: SW020412 PID#: 050-292-06 Legal Description: Eagle Crest #1 Tract B Lot 19 Engineer: Anderson Engineerinq Applicant: Stuart McKenzie Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 1.0 feet to the south. property line and 6 ft to the east property line. In addition, your request for a waiver of the required 5 feet separation between the septic tank and absorption field has been approved. The approved separation distance is 4.0 feet. See engineer's waiver request for justifications. This waiver approval applies to the existing absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. ■ a a a a a a a a a a a a a a a a e a a a a a■■ a a a a a a a a a n a a e a a a a a a a a v a a a a a a s a a a a a a a a a 0 a a a a a a a a a a a 1 Waiver is Granted: X Waiver is not Granted.- Date: ranted. Date: /_� 0 Approved by: �av6e& I Name of Reviewer a■a■a■aa■maaaacaaea■asses■aaasa■ease■seem■aaaaaaaaaa■■■aaaaaaaa■aaaemaaaaaaa■a� June 10, 2015 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 19, Tract B, Eagle Crest Subdivision First Addition Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The absorption system was placed on the subject lot in May of 2003. Insufficient survey control was apparently used in the location of the absorption trench as it was constructed at 6' from the east property line and 2' from the south property line. Both the primary and reserve sites were constructed at the same time. The subdivision is served by the Municipal water system and no conflicts exist with the neighboring septic system. Accepting soils in the area of the absorption system are clean gravel with excellent absorption characteristics. No migration of effluent is expected. We recommend a waiver be issued allowing the absorption system to remain 6' from the east property line and 2' from the south property line. Sincerely, Michael E. Anderson, P.E. • E, �....... qs �♦ .� •49th MICHAEL E. ANDERSON No. CE -4381 pROFE S O P :::� 66b- 2a2-111,- c�ln11-5- 2A5 i-5- 2 5 osv i°s toS�' __.... ANDERSON .ENGINEERING: PO. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) June 17, 2015 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 19, Tract B, Eagle Crest Subdivision First Addition Separation Distance Waiver Septic Tank to Trench Sidewall Dear On Site Services Engineer: The absorption system was placed on the subject lot in May of 2003. Insufficient survey control was apparently used in the location of the septic tank and trench sidewall as they are less than 5' apart at the southeast end. The majority of the tank exceeds the 5' separation requirement, but the southeast corner is 4' from the sidewall. Soils in the area are clean sand and gravel with effluent migration downward rather than to the side. We recommend a waiver be issued allowing the septic tank to remain less than 5' from the trench sidewall. Sincerely, ��-1�•C� F-, u4"-) Michael E. Anderson, P.E. OF E AV .° 49th•°. '.MICHAEL E. ANDERSON • NO. CE -4381 : �Zi ANDERSON ENGINEERING P:O. BOX 240773 ANCHORAGE, AK.99524 . 522-7773 677-7766 (FAX) June 10, 2015 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 19, Tract B, Eagle Crest Subdivision First Addition Separation Distance Waiver Trench Sidewall to Trench Sidewall Dear On Site Services Engineer: The absorption system was placed on the subject lot in May of 2003. Insufficient survey control was apparently used in the location of the absorption trenches as they are less than 10' apart. The distance ranges from 8' to 9'. Soils in the area are clean sand and gravel with effluent migration downward rather than to the side. A recent inspection of the trenches indicated 7" and 11" of water after a service life of 12 years. We recommend a waiver be issued allowing the absorption trenches to remain less than 10' between sidewalls. Sincerely, Michael E. Anderson, P.E. CA C0a _ngineer: -egal Description lermit: teport Type: Municipality of Anchorage P.O Box 196550 4700 Elmore Road Anchorage, Alaska 99519-6650 (907) 343-7904 Fax (907) 343-7997 http://www.muni.org/onsite Planning and Development Services Department On -Site Water and Wastewater Program On -Site Sewer[Well Submittal Comment Sheet ANDERSON ENGINEERING EAGLE CREST #1 TR B LT 19 OSV151056 Variance Variance Review Completed By: -he attached paperwork has been reviewed and is being returned for the following reasons: ti"�1 t 7l j' �A 4 <Q u r� r� l)Cpar•tlnent 6/22/2015 J.Crewdson 1. Inspection Report: Please provide. Note: Review of this waiver request is not complete, and is on hold until the final inspection report and asbuilt drawings are made available for review. The original design for the septic system on this lot was completed by Anderson Engineering in October of 2002. We ha( little contact with the owner after that point. The system was constructed in May of 2003 by Everett Caulkins. At the time was an experienced installer and for many years had been certified by the City. The inspections were called in and recor by the City. We are unsure who actually called them in and assume it was the excavator. The design was apparently changed in the field and the owner and installer thought they were placing both the original and alternate absorption sites Although The trench size is more than sufficient for the primary site it is not large enough to meet both the primary and alternate requirements. An alternate site is shown on the east side of the existing driveway serving the home. We became involved recently when the owner decided to sell the house and needed the COSA certification. Additional cleanouts were added and the length, width and depth of the absorption trenches were verified. It is our opinion the exist system more than meets the requirements for the four bedroom home on the lot. A lot line waiver is necessary as the absorption trenches are less than 10' from the west and south property lines. r'�A7 r MUNICIPALITY OF ANCHORAGE C, ?'', Development Services Department �X On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SW020412 Legal Description: EAGLE CREST#1 TR B LT 19 Date Issued: Oct 15, 2002 Expiration Date: Oct 15, 2003 Parcel ID: 050-292-06 Design Engineer: 0013 C.A. Excavating Site Address: 018939 SECOND ST Owner Name: Stuart McKenzie Lot Size: 17820 SQ. FT. Owner Address: 19035 Sarichef Loop Total Bedrooms: 4 Permit Bedrooms: 4 Eagle River, AK 99577 - This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: /d "-11? 00?r Issued By: r—Y Date: la1/5 0 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 0 `i Permit Number SW Property owner(s) Stuart and Debora Mckenzie Day phone 688-6176 Mailing address (1) 19035Sarichef Loop Eagle River, AK 99577 Mailing address Code Legal description (Lot, Block & Sub'd.) Lot 19 Tract B, n EAJ /e ( f Ss -A,- ] Legal description (Section, Township & Range) Lot Size 17,820 SF Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms Four (4) Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi Swimming Pool ❑ Water Softening Unit Therapy Pool ❑ e I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: 'a Date of Payment: 10- b " oz Receipt Number: 21,15'd '-)q (Rev. 12/00) Waiver Fees: Date of Payment: Receipt Number: October 7, 2002 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 19, Tract B, Eaglecrest Subdivision First Addition Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 19, Tract B, Eaglecrest Subdivision First Addition intends to construct a four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The attached Site Plan and backup documentation identify the location and configuration of the new septic system and alternate site and the parameters used in the design. Also identified on the plans are the proposed water service line and the test hole location. Drainage arrows are also shown and current drainage patterns will be maintained after construction. Municipal water and sewer serve all adjoining properties. This lot is served by Municipal water, but the sewer line does not cross the frontage of his property. The test holes placed near the location of the proposed absorption trench indicated gravel with varying amounts of silt with a percolation rate of less than 2 minutes per inch and 15 minutes per inch. No ground water was found and none was noted during the monitoring period. We are therefore proposing to construct a deep absorption trench system with a 37' long trench with an 8' effective depth. The distribution piping depth will be 3' below the surface. Total depth of the trench will be 11'. The alternate trench will be 47' long to compensate for the slower percolation rate. The primary trench will be extended 5' longer than design requirements. The ground surface on the lot slopes at shallow grades from north to south. The absorption trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. All components of the new septic system will be constructed a minimum of 10' from the water service line on the lot and on the adjacent lot. The system will also be constructed a minimum of 100' from any surface water in the area. Some surface water was noted in the electrical easement at the back of the lot. If the system is constructed in accordance with our design the following statements Lot 19, Tract B, Eaglecrest No. 1 October 7, 2002 Page Two apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The subdivision is currently served by the Municipal water system. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, n `1D a L xL Michael E. Anderson, P.E. Attachments 49th MICHAEL E. ANDERSON No. CE -4381 THIRD STRFRT 20 73.11 132.00 132.00 132.00 % M NM 18 17 16 n Eu 5 0 Water 15' 101 Util Esnt City wat rR A C T B 20d Sewer 21 132.00 29 r AREA SYSTEM PLAN to 'v��•i�� SCALE 1" = 80' % No. CE- Bi _• LOT 19 City Water and S wer W Fm Bcaronn � o o . sEcoxo smee'r' .20 72.07 132.00 c N 1 0 5 30 101 Util Esnt City wat rR A C T B 20d Sewer 21 132.00 29 r AREA SYSTEM PLAN to 'v��•i�� SCALE 1" = 80' „�,�� ........................ ; MICHAEL E ANDERSON No. CE- Bi _• klivis o SECOND STREET SITE PLAN SCALE 1" = 20' LOT 19, TRACT B, EAGLECREST SUBDIVISION FIRST ADDITION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Deep Trench System Perc. Rate: 1.7 Min./inch 1,250 Gallon Septic Tank Avg. Application Rate: 1.2 GPD/SF 8' Drain Field Rock 4 Bedrooms X 150 GPD 11.2 GPD/SF = 500 SF of Absorption Area 500 SF/16 SF/LF = 31.25 LF Trench Length Therefore: Oversize the Trench From Design Requirements. Construct an 4bsorption Trench 37' in Length by 3' Wide With 8' of Drainfield Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 3' Below Existing Ground . Total Depth of Trench to Be 11' Below Existing Surface. Cover Over Septic Tank a Minimum of 4' or 2" of Insulation and 2' of Cover. Natural 216" Backfill Geotextile Fabric 6" 40 ), 810" Draintield Rock 3' TYPICAL DEEP TRENCH SECTION '` 40:1b (NO SCALE) .G. ,.. r^= NOTE: Grade Area Over Trench to Drain Awa ""° » y' d�'"» MtCNAEi i Ah!'2r :x"J'.d Minimum 6' Separation From Bedrock. CE 4x381 Minimum 10' From Lot Line. Minimum 4' Separation From Groundwater.Minimum 100' aF�•.,, aa.�.•�` e Area. Minimum 10' SepaSeparation l rat on From Water Service Line. 4�' k > i L7r 19� 49th GV Municipality of Anchorage Development Services Department i ..................:..... ... :.. 4700 South Bragaw, Anchorage, AK 99519-0650 �� .MICNA-� E. ANDERSON ;4 SOILS LOG - PERCOLATION TEST ��%rT+, No. cE-4381r���' D'................. Performed For: Forty-Niner Real Estate Date Performed: 7/12/02 041,4 VAX Legal Description: Lot 19, Tract B. Eagle Crest No. 1 1 1 1 1 1 1 1 1 1 1 TESTHOLE NO. 1 Silty Gravel with Sand GM Bottom of Hole \ 20% 0% Was Groundwater Encountered? No If Yes, What Depth? Depth to Water After Monitoring None Date: 7/14/02 TH1 • Second Street 0% Reading jDate Gross lime Net Time Depth To Net Water lDrop 1 12 -Jul 5:15 .13" 2 5:25 10 Dry 6" 3 5:26 .13" 4 5:36 10 Dry 6" 5 5:37 .13" 6 5:47 10 Dry 6" Perc. Rate: 1.7 Min./Inch Perc. Hole Diameter. 6" Test Run Between 4 Ft. and 5 Ft. Comments: Percolation Cavity Presoaked Prior to Testing. Performed By: Mike Anderson. 1, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 7/14/02 1 2 3 4 5 6 7 8 9 MUNICIPALITY OF ANCHORAGE BUILDING SAFETY DEPARTMENT/ON-SITE WATER AND WASTEWATER PROGRAM 4700 SOUTH BRAGAW STREET, ANCHORAGE, AK 99502-0605 SOILS LOG - PERCOLATION TEST PROJECT #: M0241 PERFORMED FOR: JIM/STRATA LEGAL DESCRIPTION: LOT 19, TRACT B. EAGLE CREST SUED FIRST ADDITION TFCT Hnl F # 2 SLOPE 25% I SP 4. GW DATE PERFORMED: 8/15/02 SITE PLAN WAS GROUNDWATER GROSS TIME N ENCOUNTERED? YES TH1 TH2 0 0 1 MICH A EE E. ANDERSON 4 WAS GROUNDWATER GROSS TIME 1� 49th ENCOUNTERED? YES S 1 MICH A EE E. ANDERSON 4 1 •�C�f '., NO. CE-4381.Q•�= L IF YES, WHAT DEPTH? 17 FT 0 GM 1610 6.5" 2 P DEPTH OF WATER None Recharge AFTER MONITORING: E DATE: 9/15/2002 30 READING DATE GROSS TIME 1� 49th DEPTH OF NET WATER DROP Start 8/15/02 15-40 1 MICH A EE E. ANDERSON 4 1 •�C�f '., NO. CE-4381.Q•�= 1 1610 BOH �1�0 PRnc�oci(1NP�0� READING DATE GROSS TIME NET TIME DEPTH OF NET WATER DROP Start 8/15/02 15-40 6- 1 1610 30 3.875" 2.125" Recharge 1610 6.5" 2 1640 30 4 5" 7 - Recharge 16:40 6 5" 3 17:10 30 4.5" 2 9/15/2002 PERC RATE: 15 MIN./INCH PERC. HOLE DIAMETER:6" TEST RUN BETWEEN 5.5 FT. AND 6-5 FT. COMMENTS NO IMPERMEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST TEST PERFORMED BY: T.L. KIMBROUGH I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 10/7/2002 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 19, TRACT B, EAGLECREST SUBDIVISION FIRST ADDN. GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the site plan and the construction of a new 37' long by T wide by 8' effective depth absorption trench also shown on the Site Plan. The total depth of the trench will be 11' below existing ground and the distribution pipe will be placed at 3' below the surface. All components of the septic tank and absorption trench must be constructed a minimum of 10' from the water service to be constructed on the lot. A minimum of 4' of fill must be placed atop the septic tank and 3' of fill above the absorption trenches. In lieu of fill 2" of direct bury insulation may be placed with 2' of fill atop the insulation. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. The 1,250 -gallon septic tank must be procured from an approved septic tank manufacturer and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. Lot 19, Tract B, Eaglecrest No. 1 October 7, 2002 Page 2 of 2 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). Lot 19, Tract B, Eaglecrest No. 1 October 7, 2002 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5' to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection., Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. • Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 Certificate of On -Site Systems Approval Parcel I.D. 050-292-06 1. GENERAL INFORMATION Expiration Date: 6— Complete Complete legal description Eagle Crest #1, Tract B, Lot 19 Location (Site address) 18939 Second Street Eagle River, AK 99577 Current Property owner(s) Stuart McKenzie Day phone 808-634-8406 Mailing address Real Estate Agent 6480 Opaekaa Road Kapaa, HI 96746 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: Four Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System 0 Public Sewer ❑ WaiverNariance request for: Distance: Received by Date: Z ^fS, COSA to be releasd€f to 01p4ngineer, unless oth rvvi requested by the engineer. COSA Fee $ 5a� Waiver Fee $- Date of Payment CQI�IS Date of Payment,Z 3 - %5 Receipt Number OV40 Receipt Number Lt 6, 1 9 d COSA # 05C151 I Waiver # O'S V 15 10 E> (o 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE System #1 Approved for �- bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, Phone 522-7773 Date. 6/17/2015 wit% OF Pj too 49TH7. .............. �+ �MICAE E. ANDERSONo •: �® �s°•• CE - 4381 ROFESS10�a®®® with the following stipulations. 11% 0FA�Vf r J - G� WATER AND WASTEWATER o^ PR Jam' �JJ�i;FNT 11))))))1111 By: , Original Certificate Date: Thelvluni ar of orage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA blue sheet—f '- 't c Nitrate Advisory Arsenic Advisory' Other If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Eagle Crest No. 1, Tract B, Lot 19 Parcel ID: 050-292-06 A. WELL DATA Well type If A, B, or C provide PWSID # Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production g.p.m. 9.p -m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1,250 gal. Number of Compartments 2 Foundation cleanout (Y/N) Y Depression over tank (Y/N) N Date of pumping 7/23/14 Pumper JRs Pumping C. ABSORPTION FIELD DATA Date installed 5/25/2003 Cleanouts (Y/N) Y High water alarm (Y/N) N Date installed 5/25/2003 Soil rating (g.p.d./ft2 or ft2/bdrm) •8 GPD/SF System type 5' Wide Length 47' and 51' ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 9 ft. Eff. absorption area 980 ft2 Monitoring tube Y Depression over field N Date of adequacy test 6/9/15 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 7/14 in. Water added 627 gal. New depth 11/21 in. Elapsed Time: 1,440 min. Final fluid depth 7/14 in. Absorption rate >= 600 g p d Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed "Pump on" level at Datum No Add On Manhole - Gravity Flow to Absorption Trench. Size in gallons _ in. "Pump off' level at Cycles tested E. SEPARATION DISTANCES WELL ON LOT TO: Manhole/Access (Y/N) in. High water alarm level at Meets alarm & circuit requirements? Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer /septic service line Holding tank Animal containment areas Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation >51 Property line >51 Water main > 0 Water service line >10' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: '*** Property line 1Building foundation >10' Water Service line >10' Surface water >100 Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS ***See Lot Line Waiver. G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 6/17/2015 COSA brown sheet 10-10-12.doc Absorption field >51 Surface water > 100' Water main N/A Driveway, parking/vehicle storage >I 0, in. 10t OF �As9 (� TH s • •o' f� V01. MICHAEL E. ANDERSONAW• �� ,J,•°° CE - 4381 •.'��AW`mO AW FpAft,®�a4d®maS�� N8958"W 132. 00 10" UTILITY EASEMENT ------------------------------------------------------------------ �0 GO xis SINGLE FAM1L Y FRAME HOUSE 0 44.9 CANT. ___________________5__ DECK--- ' ________ O O O O O � O ZQT O O O y0 T O co O N 89 58'W 132.00 SECOND STREET THE INFORMATION HEREON I5 FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS: AND 15 NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES. EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT, ARE NOT SHOWN HEREON( UNLESS INDICATED) NOTE: FENCELINE5 THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. O O M h U)1�1^ V Do O O O Z G000ppppp OFA��� o.......... _V 15?�4 0 * 49 T C oO s� SHANE A. HOLT �G ----- -- �4P� LS -6914 504 AS -BUILT SURVEY V = 20'4��Opfooiona% � NO CORNERS SET THIS DATE I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT 19, TRACT B, EAGLE CREST FIRST ADDITION ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST OTHER THAN NOTED. DATED AT ANCHORAGE,ALASKA THIS _21ST DAY OF _MAY , 2015. HOLT LAND SURVEYING 600 H16HVIEW DRIVE ANCHORAGE,AK 99515 12947. FS 171-40 345-5513