ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: SW020412 PID Number: 050-292-06 ❑ New ❑Upgrade
Name:
Stuart McKenzie
ABSORPTION FIELD
❑✓ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address
18939 Second Street Eagle River, AK 99577
❑ Other
Phone
Number of Bedrooms
Soil Rating , .
Total depth from original grade
4
•8 GPD/SF
8.8-9 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
6.8-7 Ft.
Gravel depth beneath pipe
4.0 Ft.
Subdivision Block Lot
Eagle Crest No. 1 B 19
Fill added above original grade
0-.5 Ft.
Gravel length
98 Ft.
Township Range Section
Gravel width
5Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
980 Ft2
Two
8-9 Ft.
Well
NA
NA
NA
NA
>25'
TANK p Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
1 1,250Gal.
Surface Water
>100'
>100'
>100'
>100'
Material
Number of compartments
Lot Line
>5'
1'
N/A
N/A
Steel
Two
NA
Foundation
>5'
>10'
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
None
Noted
Gal.
Remarks Lot Served by AWWU Water System.
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
See Lot Line Waiver.
System was installed on May 25, 2003. No inspections
Pump make and model
Electrical Inspections performed by
were completed during construction.
Installer
PIPE MATERIAL House to tank D3034Tank to D3034
drainfield
Everett Caulkins
Drainfield HDPE CO/MT D3034
Inspector MEA - Verify Dimensions of System
BENCH MARK (Assumed elevation) 100.Oft
Inspection 1st 6/12/15
dates: 2"d 6/13/15
Location and description
3rd 6/14/15 4'h
Bottom Step Front Entrance.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
OF 4
��•`
Conditional Approval: Date _
,...
:...,G �d1
� .
A
� ;
AV �j; •, 0
I
*.'
Ash' 9 TH
. *0
josam ...r re . ........ .....:.
MICHAEL E. ANDERSON
CE - 4381
�
Approved ;'
pp Date®
Inspection Report -1-1-12/110c
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
Permit No.: SW020412 On -Site Wastewater Disposal System or Well Inspection Report
0
0
L6
co
in
v
co
0
o
Z
ALTERNATE SITE:
Advantex Treatment System with
10' long x 3' Wide x 8' Effective
Depth Absorption Trench.
Application Rate 5 GPD/SF.
49th W
....... r......jJ...
�..,
�'. .......:1
MICHAEL E. ANDERSON
f No, CE -4381
��♦♦1,sfROF
_ SSIi&ii
EAGLE CREST NO. 1
TRACT B, LCT 19
N 89 58'W 132.00
10' UTILITY EASEMENT
-----------------------------------------------------------------------
I A I B I C
S2
20.1'
39.4'
C4
31.2'
51.1-
05
25.4'
11.5'
M1
21.7'
8.7'
M2
30.4'
52.1'
C6
41.3'
64.2'
M3
38.8'
27.8'
C8
38.5'
26.1'
Four Bedroom Home
'C" e, J
i
Cn Q�
®rH1
Alternate Site
N 89 58'W 132.00
a
C4
eH2 ;7 M2
c7
-------- ------------- C6
Page 2 of 3
PID No. 050-292-06
SECOND STREET
LEGEND
SV — Septic Vent
CO — Clean Out
MT — Monitor Tube
M I n A I A f-' T1 I I T I T TH — Test Hole
SCALE 1' = 30'
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: SW020412
Page 3 of 3
PID No. 050-292-06
00 M
t 75
N
2
47' (Trench Length)
)C9
PROFILE
No Scale
51' (Trench Length)
AS -BUILT
95.2
95.0
v �J;
r
49th
:`........j` .o
P
... ......................
MICHAEL E. ANDERSON
No, CE -4381 =moo
1� 00%FESS �.
EAGLE CREST SUBDIVISION NO. 1
LOT 19, TRACT B
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom Home 5' Wide Trench System
Perc. Rate: 15 Min./Inch 1,250 Gallon Septic Tank
Application Rate: .8 GPD/SF 4' Drainfield Rock
4 Bedrooms * 150 GPD/Bedroom = 600 SF Absorption Area
600 SF/.8 GPD/SF/5 SF (Width) *.5 (Red. Factor)= 56.25 LF Trench Length
THEREFORE: Construct a 57' Long x 5' Wide x 4' Effective Depth Absorption Trench.
Flow Line Elevation in Trench to be 4' Below Original Ground Surface. Total Depth to be
8' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over
Septic Tank.
5'
TYPICAL 5' WIDE TRENCH SECTION
(NO SCALE)
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock. ■. .
Minimum 4' Separation From Groundwater. 2�
Minimum 100' Separation From Private Wells in the Area. Jg
Minimum 100' Separation From Surface Water or Streams. sod
=
MICHAEL E. ANDERSON
�•
No. CE -0381
T '
46 _°ROFESSM�Pi
Z
P.O. Box 196650 e 4700 Elmore Road
Anchorage, Alaska 99519-6650 e (907) 343-7904 e Fax (907) 343-7997
http://www.muni.org/Onsite
Development Services Department
On -Site Water and Wastewater Section
hien!
1)cp;vtment
*** / * * * *
Waiver#: OSV151056 COSA#: OSC151056 Permit#: SW020412
PID#: 050-292-06
Legal Description: Eagle Crest #1 Tract B Lot 19
Engineer: Anderson Engineerinq
Applicant: Stuart McKenzie
Your request for a waiver of the required 10 feet horizontal separation from the absorption field
to the property line has been approved. The approved separation distance is 1.0 feet to the south.
property line and 6 ft to the east property line. In addition, your request for a waiver of the
required 5 feet separation between the septic tank and absorption field has been approved. The
approved separation distance is 4.0 feet. See engineer's waiver request for justifications.
This waiver approval applies to the existing absorption field only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
■ a a a a a a a a a a a a a a a a e a a a a a■■ a a a a a a a a a n a a e a a a a a a a a v a a a a a a s a a a a a a a a a 0 a a a a a a a a a a a 1
Waiver is Granted: X Waiver is not Granted.-
Date:
ranted.
Date: /_� 0 Approved by: �av6e&
I Name of Reviewer
a■a■a■aa■maaaacaaea■asses■aaasa■ease■seem■aaaaaaaaaa■■■aaaaaaaa■aaaemaaaaaaa■a�
June 10, 2015
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: Lot 19, Tract B, Eagle Crest Subdivision First Addition
Separation Distance Waiver
Absorption Trench to Lot Line
Dear On Site Services Engineer:
The absorption system was placed on the subject lot in May of 2003. Insufficient
survey control was apparently used in the location of the absorption trench as it was
constructed at 6' from the east property line and 2' from the south property line. Both
the primary and reserve sites were constructed at the same time.
The subdivision is served by the Municipal water system and no conflicts exist with the
neighboring septic system. Accepting soils in the area of the absorption system are
clean gravel with excellent absorption characteristics. No migration of effluent is
expected. We recommend a waiver be issued allowing the absorption system to remain
6' from the east property line and 2' from the south property line.
Sincerely,
Michael E. Anderson, P.E.
•
E, �....... qs �♦
.� •49th
MICHAEL E. ANDERSON
No. CE -4381
pROFE S O P :::�
66b- 2a2-111,-
c�ln11-5-
2A5
i-5-
2 5
osv i°s toS�'
__....
ANDERSON .ENGINEERING:
PO. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
June 17, 2015
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: Lot 19, Tract B, Eagle Crest Subdivision First Addition
Separation Distance Waiver
Septic Tank to Trench Sidewall
Dear On Site Services Engineer:
The absorption system was placed on the subject lot in May of 2003. Insufficient
survey control was apparently used in the location of the septic tank and trench sidewall
as they are less than 5' apart at the southeast end. The majority of the tank exceeds
the 5' separation requirement, but the southeast corner is 4' from the sidewall. Soils in
the area are clean sand and gravel with effluent migration downward rather than to the
side.
We recommend a waiver be issued allowing the septic tank to remain less than 5' from
the trench sidewall.
Sincerely,
��-1�•C� F-, u4"-)
Michael E. Anderson, P.E.
OF
E
AV
.° 49th•°.
'.MICHAEL E. ANDERSON
• NO. CE -4381 : �Zi
ANDERSON ENGINEERING
P:O. BOX 240773
ANCHORAGE, AK.99524 .
522-7773 677-7766 (FAX)
June 10, 2015
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: Lot 19, Tract B, Eagle Crest Subdivision First Addition
Separation Distance Waiver
Trench Sidewall to Trench Sidewall
Dear On Site Services Engineer:
The absorption system was placed on the subject lot in May of 2003. Insufficient
survey control was apparently used in the location of the absorption trenches as they
are less than 10' apart. The distance ranges from 8' to 9'. Soils in the area are clean
sand and gravel with effluent migration downward rather than to the side. A recent
inspection of the trenches indicated 7" and 11" of water after a service life of 12 years.
We recommend a waiver be issued allowing the absorption trenches to remain less
than 10' between sidewalls.
Sincerely,
Michael E. Anderson, P.E.
CA C0a
_ngineer:
-egal Description
lermit:
teport Type:
Municipality of Anchorage
P.O Box 196550 4700 Elmore Road
Anchorage, Alaska 99519-6650 (907) 343-7904 Fax (907) 343-7997
http://www.muni.org/onsite
Planning and Development Services Department
On -Site Water and Wastewater Program
On -Site Sewer[Well Submittal Comment Sheet
ANDERSON ENGINEERING
EAGLE CREST #1 TR B LT 19
OSV151056 Variance
Variance Review
Completed By:
-he attached paperwork has been reviewed and is being returned for the following reasons:
ti"�1 t 7l j'
�A 4
<Q
u r�
r�
l)Cpar•tlnent
6/22/2015
J.Crewdson
1. Inspection Report: Please provide.
Note: Review of this waiver request is not complete, and is on hold until the final inspection report and asbuilt
drawings are made available for review.
The original design for the septic system on this lot was completed by Anderson Engineering in October of 2002. We ha(
little contact with the owner after that point. The system was constructed in May of 2003 by Everett Caulkins. At the time
was an experienced installer and for many years had been certified by the City. The inspections were called in and recor
by the City. We are unsure who actually called them in and assume it was the excavator. The design was apparently
changed in the field and the owner and installer thought they were placing both the original and alternate absorption sites
Although The trench size is more than sufficient for the primary site it is not large enough to meet both the primary and
alternate requirements. An alternate site is shown on the east side of the existing driveway serving the home.
We became involved recently when the owner decided to sell the house and needed the COSA certification. Additional
cleanouts were added and the length, width and depth of the absorption trenches were verified. It is our opinion the exist
system more than meets the requirements for the four bedroom home on the lot.
A lot line waiver is necessary as the absorption trenches are less than 10' from the west and south property lines.
r'�A7
r MUNICIPALITY OF ANCHORAGE C, ?'',
Development Services Department �X
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Permit Number: SW020412
Legal Description: EAGLE CREST#1 TR B LT 19
Date Issued: Oct 15, 2002
Expiration Date: Oct 15, 2003
Parcel ID: 050-292-06
Design Engineer: 0013 C.A. Excavating Site Address: 018939 SECOND ST
Owner Name: Stuart McKenzie Lot Size: 17820 SQ. FT.
Owner Address: 19035 Sarichef Loop Total Bedrooms: 4 Permit Bedrooms: 4
Eagle River, AK 99577 -
This permit is for the construction of:
❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Date: /d "-11? 00?r
Issued By: r—Y Date: la1/5 0
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 0 `i Permit Number SW
Property owner(s) Stuart and Debora Mckenzie Day phone 688-6176
Mailing address (1) 19035Sarichef Loop Eagle River, AK 99577
Mailing address
Code
Legal description (Lot, Block & Sub'd.) Lot 19 Tract B, n EAJ /e ( f Ss -A,- ]
Legal description (Section, Township & Range)
Lot Size 17,820 SF Acres/Sq.Ft.
THIS APPLICATION IS FOR:
Number of Bedrooms Four (4)
Sewer Only ® Well Only ❑
Sewer and Well ❑ Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi
Swimming Pool ❑ Water Softening Unit
Therapy Pool ❑
e
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees: 'a
Date of Payment: 10- b " oz
Receipt Number: 21,15'd '-)q
(Rev. 12/00)
Waiver Fees:
Date of Payment:
Receipt Number:
October 7, 2002
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 19, Tract B, Eaglecrest Subdivision First Addition
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 19, Tract B, Eaglecrest Subdivision First Addition intends to construct
a four-bedroom home on the lot. We are therefore requesting a permit be issued for
the construction of a new septic system to serve the new home. The attached Site
Plan and backup documentation identify the location and configuration of the new
septic system and alternate site and the parameters used in the design. Also identified
on the plans are the proposed water service line and the test hole location. Drainage
arrows are also shown and current drainage patterns will be maintained after
construction. Municipal water and sewer serve all adjoining properties. This lot is
served by Municipal water, but the sewer line does not cross the frontage of his
property.
The test holes placed near the location of the proposed absorption trench indicated
gravel with varying amounts of silt with a percolation rate of less than 2 minutes per
inch and 15 minutes per inch. No ground water was found and none was noted during
the monitoring period. We are therefore proposing to construct a deep absorption
trench system with a 37' long trench with an 8' effective depth. The distribution piping
depth will be 3' below the surface. Total depth of the trench will be 11'. The alternate
trench will be 47' long to compensate for the slower percolation rate. The primary
trench will be extended 5' longer than design requirements.
The ground surface on the lot slopes at shallow grades from north to south. The
absorption trench will be constructed parallel with the slope as much as possible in
conformance with Municipal requirements. All components of the new septic system
will be constructed a minimum of 10' from the water service line on the lot and on the
adjacent lot. The system will also be constructed a minimum of 100' from any surface
water in the area. Some surface water was noted in the electrical easement at the back
of the lot.
If the system is constructed in accordance with our design the following statements
Lot 19, Tract B, Eaglecrest No. 1
October 7, 2002
Page Two
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future. The subdivision is currently
served by the Municipal water system.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely, n
`1D a L xL
Michael E. Anderson, P.E.
Attachments
49th
MICHAEL E. ANDERSON
No. CE -4381
THIRD STRFRT
20
73.11
132.00
132.00 132.00
%
M NM
18
17 16
n
Eu
5 0
Water
15'
101 Util Esnt
City wat rR A C T B
20d Sewer 21
132.00
29
r
AREA SYSTEM PLAN
to 'v��•i��
SCALE 1" = 80'
%
No. CE- Bi _•
LOT 19
City
Water
and
S
wer
W
Fm Bcaronn
�
o
o
.
sEcoxo smee'r'
.20
72.07
132.00
c
N
1
0 5
30
101 Util Esnt
City wat rR A C T B
20d Sewer 21
132.00
29
r
AREA SYSTEM PLAN
to 'v��•i��
SCALE 1" = 80'
„�,��
........................
; MICHAEL E ANDERSON
No. CE- Bi _•
klivis o
SECOND STREET
SITE PLAN
SCALE 1" = 20'
LOT 19, TRACT B, EAGLECREST
SUBDIVISION FIRST ADDITION
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Four Bedroom Home Deep Trench System
Perc. Rate: 1.7 Min./inch 1,250 Gallon Septic Tank
Avg. Application Rate: 1.2 GPD/SF 8' Drain Field Rock
4 Bedrooms X 150 GPD 11.2 GPD/SF = 500 SF of Absorption Area
500 SF/16 SF/LF = 31.25 LF Trench Length
Therefore: Oversize the Trench From Design Requirements. Construct an 4bsorption
Trench 37' in Length by 3' Wide With 8' of Drainfield Rock Beneath the Distribution Lateral.
Distribution Lateral to Be Placed 3' Below Existing Ground . Total Depth of Trench to Be
11' Below Existing Surface. Cover Over Septic Tank a Minimum of 4' or 2" of Insulation
and 2' of Cover.
Natural
216" Backfill
Geotextile
Fabric
6"
40 ),
810" Draintield Rock
3'
TYPICAL DEEP TRENCH SECTION '` 40:1b
(NO SCALE) .G. ,..
r^=
NOTE: Grade Area Over Trench to Drain Awa ""° »
y' d�'"» MtCNAEi i Ah!'2r :x"J'.d
Minimum 6' Separation From Bedrock. CE 4x381
Minimum 10' From Lot Line.
Minimum 4' Separation From Groundwater.Minimum 100' aF�•.,, aa.�.•�`
e Area.
Minimum 10' SepaSeparation l
rat on From Water Service Line. 4�' k >
i L7r 19�
49th GV
Municipality of Anchorage
Development Services Department i ..................:..... ... :..
4700 South Bragaw, Anchorage, AK 99519-0650 �� .MICNA-� E. ANDERSON ;4
SOILS LOG - PERCOLATION TEST ��%rT+, No. cE-4381r���'
D'.................
Performed For: Forty-Niner Real Estate Date Performed: 7/12/02 041,4 VAX
Legal Description: Lot 19, Tract B. Eagle Crest No. 1
1
1
1
1
1
1
1
1
1
1
TESTHOLE NO. 1
Silty Gravel
with Sand
GM
Bottom of
Hole
\ 20%
0%
Was Groundwater
Encountered? No
If Yes, What Depth?
Depth to Water
After Monitoring None
Date: 7/14/02
TH1
•
Second Street
0%
Reading
jDate Gross
lime
Net
Time
Depth To Net
Water lDrop
1
12 -Jul 5:15
.13"
2
5:25
10
Dry 6"
3
5:26
.13"
4
5:36
10
Dry 6"
5
5:37
.13"
6
5:47
10
Dry 6"
Perc. Rate: 1.7 Min./Inch Perc. Hole Diameter. 6"
Test Run Between 4 Ft. and 5 Ft.
Comments: Percolation Cavity Presoaked Prior to Testing.
Performed By: Mike Anderson. 1, Michael E. Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 7/14/02
1
2
3
4
5
6
7
8
9
MUNICIPALITY OF ANCHORAGE
BUILDING SAFETY DEPARTMENT/ON-SITE WATER AND WASTEWATER PROGRAM
4700 SOUTH BRAGAW STREET, ANCHORAGE, AK 99502-0605
SOILS LOG - PERCOLATION TEST
PROJECT #: M0241
PERFORMED FOR: JIM/STRATA
LEGAL DESCRIPTION: LOT 19, TRACT B. EAGLE CREST SUED FIRST ADDITION
TFCT Hnl F # 2 SLOPE
25% I
SP
4.
GW
DATE PERFORMED: 8/15/02
SITE PLAN
WAS GROUNDWATER
GROSS
TIME
N
ENCOUNTERED?
YES
TH1 TH2
0 0
1 MICH A EE E. ANDERSON 4
WAS GROUNDWATER
GROSS
TIME
1� 49th
ENCOUNTERED?
YES
S
1 MICH A EE E. ANDERSON 4
1 •�C�f '., NO. CE-4381.Q•�=
L
IF YES, WHAT DEPTH?
17 FT
0
GM
1610
6.5"
2
P
DEPTH OF WATER
None
Recharge
AFTER MONITORING:
E
DATE:
9/15/2002
30
READING DATE
GROSS
TIME
1� 49th
DEPTH OF NET
WATER DROP
Start 8/15/02
15-40
1 MICH A EE E. ANDERSON 4
1 •�C�f '., NO. CE-4381.Q•�=
1
1610
BOH �1�0 PRnc�oci(1NP�0�
READING DATE
GROSS
TIME
NET
TIME
DEPTH OF NET
WATER DROP
Start 8/15/02
15-40
6-
1
1610
30
3.875" 2.125"
Recharge
1610
6.5"
2
1640
30
4 5" 7 -
Recharge
16:40
6 5"
3
17:10
30
4.5" 2
9/15/2002
PERC RATE: 15 MIN./INCH PERC. HOLE DIAMETER:6"
TEST RUN BETWEEN 5.5 FT. AND 6-5 FT.
COMMENTS NO IMPERMEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST
TEST PERFORMED BY: T.L. KIMBROUGH I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 10/7/2002
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 19, TRACT B, EAGLECREST SUBDIVISION FIRST ADDN.
GENERAL:
1. The scope of this project includes the procurement and placement of a
new 1,250 -gallon septic tank at the location shown on the site plan
and the construction of a new 37' long by T wide by 8' effective depth
absorption trench also shown on the Site Plan. The total depth of the
trench will be 11' below existing ground and the distribution pipe will be
placed at 3' below the surface. All components of the septic tank and
absorption trench must be constructed a minimum of 10' from the
water service to be constructed on the lot. A minimum of 4' of fill must
be placed atop the septic tank and 3' of fill above the absorption
trenches. In lieu of fill 2" of direct bury insulation may be placed with 2'
of fill atop the insulation.
2. Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
4. Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. The 1,250 -gallon septic tank must be procured from an approved
septic tank manufacturer and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
Lot 19, Tract B, Eaglecrest No. 1
October 7, 2002
Page 2 of 2
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
6. Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
Lot 19, Tract B, Eaglecrest No. 1
October 7, 2002
Page 3 of 3
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5' to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.,
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as -built of the completed system.
• Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904
Certificate of On -Site Systems Approval
Parcel I.D. 050-292-06
1. GENERAL INFORMATION
Expiration Date: 6—
Complete
Complete legal description Eagle Crest #1, Tract B, Lot 19
Location (Site address) 18939 Second Street Eagle River, AK 99577
Current Property owner(s) Stuart McKenzie Day phone 808-634-8406
Mailing address
Real Estate Agent
6480 Opaekaa Road Kapaa, HI 96746
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: Four
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
❑
Individual
0
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public Water System
0
Public Sewer
❑
WaiverNariance request for: Distance:
Received by Date: Z ^fS,
COSA to be releasd€f to 01p4ngineer, unless oth rvvi requested by the engineer.
COSA Fee $ 5a� Waiver Fee $-
Date of Payment CQI�IS Date of Payment,Z 3 - %5
Receipt Number OV40 Receipt Number Lt 6, 1 9 d
COSA # 05C151 I Waiver # O'S V 15 10 E> (o
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
6. DSD SIGNATURE
System #1 Approved for �- bedrooms
System #2 Approved for bedrooms
Disapproved
Conditional approval for bedrooms,
Phone 522-7773
Date. 6/17/2015
wit%
OF Pj too
49TH7.
.............. �+
�MICAE E. ANDERSONo
•:
�® �s°•• CE - 4381
ROFESS10�a®®®
with the following stipulations. 11%
0FA�Vf
r
J - G�
WATER AND
WASTEWATER o^
PR Jam'
�JJ�i;FNT
11))))))1111
By: , Original Certificate Date:
Thelvluni ar of orage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
COSA blue sheet—f '- 't c
Nitrate Advisory
Arsenic Advisory'
Other
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: Eagle Crest No. 1, Tract B, Lot 19 Parcel ID: 050-292-06
A. WELL DATA
Well type If A, B, or C provide PWSID # Well Log (Y/N)
Date completed Sanitary seal (Y/N) Wires properly protected (Y/N)
Total depth ft. Cased to ft. Casing height (above ground) in.
FROM WELL LOG AT INSPECTION
Date of test
Static water level ft. ft.
Well production g.p.m. 9.p -m.
WATER SAMPLE RESULTS:
Coliform colonies/100 mL Nitrate mg/L
Arsenic ug/L Date of sample: Collected by:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel
Tank size 1,250 gal. Number of Compartments 2
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N
Date of pumping 7/23/14 Pumper JRs Pumping
C. ABSORPTION FIELD DATA
Date installed 5/25/2003
Cleanouts (Y/N) Y
High water alarm (Y/N)
N
Date installed 5/25/2003 Soil rating (g.p.d./ft2 or ft2/bdrm) •8 GPD/SF System type 5' Wide
Length 47' and 51' ft. Width 5 ft. Gravel below pipe 4 ft.
Total depth 9 ft. Eff. absorption area 980 ft2 Monitoring tube Y Depression over field N
Date of adequacy test 6/9/15 Results (Pass/Fail) PASS For 4 bedrooms
Fluid depth in absorption field before test 7/14 in. Water added 627 gal. New depth 11/21 in.
Elapsed Time: 1,440 min. Final fluid depth 7/14 in. Absorption rate >= 600 g p d
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date
D. LIFT STATION
Date installed
"Pump on" level at
Datum
No Add On Manhole - Gravity Flow to Absorption Trench.
Size in gallons _
in. "Pump off' level at
Cycles tested
E. SEPARATION DISTANCES
WELL ON LOT TO:
Manhole/Access (Y/N)
in. High water alarm level at
Meets alarm & circuit requirements?
Septic tank/lift station on lot
On adjacent lots
Absorption field on lot
On adjacent lots
Public sewer main
Public sewer manhole/cleanout
Sewer /septic service line
Holding tank
Animal containment areas
Manure/animal excrete storage areas
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >51 Property line >51
Water main > 0 Water service line >10'
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOT TO:
'***
Property line 1Building foundation >10'
Water Service line >10' Surface water >100
Curtain drain None Noted Wells on adjacent lots >100'
F. COMMENTS
***See Lot Line Waiver.
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 6/17/2015
COSA brown sheet 10-10-12.doc
Absorption field >51
Surface water > 100'
Water main N/A
Driveway, parking/vehicle storage >I 0,
in.
10t OF
�As9 (� TH
s
• •o'
f�
V01. MICHAEL E. ANDERSONAW•
�� ,J,•°° CE - 4381 •.'��AW`mO
AW
FpAft,®�a4d®maS��
N8958"W 132. 00
10" UTILITY EASEMENT
------------------------------------------------------------------
�0
GO
xis
SINGLE FAM1L Y
FRAME HOUSE
0
44.9
CANT.
___________________5__ DECK---
'
________ O
O
O O O
� O
ZQT O O O
y0
T
O co
O
N 89 58'W 132.00
SECOND STREET
THE INFORMATION HEREON I5 FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY
CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS: AND 15
NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES.
EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT, ARE NOT SHOWN
HEREON( UNLESS INDICATED)
NOTE: FENCELINE5 THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE
PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS.
ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE.
O
O
M
h
U)1�1^
V
Do
O
O
O
Z
G000ppppp
OFA���
o.......... _V
15?�4
0 * 49 T
C
oO s� SHANE A. HOLT �G
----- -- �4P� LS -6914 504
AS -BUILT SURVEY V = 20'4��Opfooiona% �
NO CORNERS SET THIS DATE
I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY
OF THE FOLLOWING DESCRIBED PROPERTY
LOT 19, TRACT B, EAGLE CREST FIRST ADDITION