Loading...
HomeMy WebLinkAboutNEAR POINT KNOLL BLK 2 LT 18AOnsite File Municipality of Anchorage Community Development Department Page 1 of 3 On-Site Water&Wastewater Program 4700 Elmore St. •P.O. Box 196650 Anchorage,AK 99519-6650 •http://www.muni.org/onsite •(907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number. OSP181178 PID Number: 041-021-67 11 New ['Upgrade Name: ABSORPTION FIELD CHAD HUFFORD SOUTH/NORTH Address: CO Deep Trench 0 Shallow Trench 0 Bed 0 Mound 10565 SHIVALIK CIRCLE*ANCHORAGE,AK 0 Other Phone: No.of Bedrooms: Soil Rating: Total Depth from original grade: (907) 727-7198 6 1.2 GPD/sq.Ft. *14 Ft. Depth to pipe invert from original grade: Gravel depth beneath pipe: LEGAL DESCRIPTION SEE DWG. FL 9.13&9.15 Ft Subdivision: Block: Lot: Fill added above original grade: Gravel length: NEAR POINT KNOLL 2 18A SEE DWG. Ft. 31 &**33 F, township: _ Section: _ Gravel width: Beds Number of lines: Distance between lines:- - 2.5 Ft. Ft. - SEPARATION DISTANCESTotal absorption area Number of trenches: Dist.between trenches: To Septic Absorption Lift Holding Public/Private 1080+ 2 19+ From Tank Field Station Tank Sewer Lines SQ.Ft. Ft. Well - - - - 25+ 'TANK 0 Septic 0 S.T.E.P. ❑Holding 0 Other Manufacturer. Capacity: Surface Water 100'+ 100'+ - - ANCHORAGE TANK 2000 Gal. Material- •Number of compartments. Lot Line 54. 10'+ - - N/A STEEL 2 Foundation 10'+ 10'+ LIFT STATION Curtain Drain I I Manufacturer: C ' NONE KNOWN Gal. Remarks: "Pump on'level at 'Pump off level at: High water alarm at: 'TRENCH WAS OVER EXCAVATED;SEE ATTACHED SOIL LOG WITH 7-DAY GROUNDWATER MONITORING TO 21 FEET Pump Make&Mode• Electrical Inspections performed by SOME DEBRIS WAS LOCATED ON THE EAST SIDE OF THE NORTH TRENCH.DUE TO THIS FACT.THE TRENCH WAS EXTENDED TO - ACCOUNT FOR THIS DEBRIS.IT WAS DISCUSSED WITH TIM ECKLUND ON 3/16/19 PIPE MATERIAL House to tank F628 Tank to D3034 drainfield Installer RED DOG MASONRY Drainfield D3034 CO/MT D3034 Inspector GEG, Ltd. BENCH MARK (Assumed elevation) 100.00 Ft. Inspection Dates: 1st 3/14/2019 2nd 3/15/2019 Location and Description: 3rd 3/15/2019 4th 3/16/2019 BOTTOM OF BACK DOOR THRESHOLD ENGINEER'S SEAL Community Development Department Approval 000�oo;\ Conditional approval: Date: 0� I- • 00 9 H •.-v 00 D/ D ,.. .. . .. r - f e, A. - e =:s: 0 000�s • f E— 953 ..`��D.__ i i O Approved: '\-. I Date: 49le Pp LICENS`AN\,'OfessSQ� #AECC884 400000. Inspection Report_1-1-12.doc c PERMIT NUMBER: PARCEL ID NUMBER: OSP181178 RECORD DRAWING 041-021-67 A B C DRAINFIELD 35'+TO FCC - 10.1 28.5 SLOPES GREATER THAN ST1 73.9 14.3 - 25%WR#0SV181178 ST2 76.0 26.2 - DBL1 31.6 28.5 - DBL2 30.3 25.4 - NEW 2000 GALLON C01 63.1 55.5 STEEL SEPTIC TANK MT1 62.2 57.1 - CO2 48.5 74.9 - MT2 48.3 72.2 - CO3 50.5 28.1 - DBL D: 1 . T2 51.5 32.1 01 C04 32.1 41.5 MT % Ti C04MT3 • MT4 32.2 39.5 - F■ MT// 03 - T. #5 CO 1 T2 -4', \. CO COTq \\\Q\\ ' �IIri NEW DRAINFIErD T.H.#6 DECK 44 . /,:: NEW 6 BEDROOM "! •. 2 HOUSE .-e ♦' ((n tU NEW T.H.FOR GROUNDWATER A .1-1.-•....i, •.. z MONITORING TO 21 FEET , • 7, w w '.yDRIVEWAY N N o / '•'`' in M • 1 :a .1i10 e ' SCALE: ~�� 7 40 a . • • GARNESS ENGINEERING GROUP, Ltd r •4' • LL- -=- r --, ENGINEERING SALES',CONSULTING • • 3701 E.TUDOR ROAD,SLATE 101•ANCHORAGE.AK 99507•PHONE(907)337$179'FAX(907)338-3248.WEBSITE www gamessenpneennp.tom .. •• •• • f PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0 Vf1 - rey •. _ . .-: •e• ig CHAD HUFFORD 907-727-7198 2 OF 3 •��'iJ,' •• C 79531 PROJECT/LEGAL DESCRIPTION: DRAWN BY: 1 NEAR POING KNOLL S/D; BLOCK 2, LOT 18A D.J.G. . .A. \., 4. TYPE OF WORK: DATE: 4. LICENSE•-•4 ;S 44 SEPTIC SYSTEM RECORD DRAWING 3/29/2019 #AECC884 PERMIT NUMBER: RECORD D 1 VFW I N G PARCEL ID NUMBER: OSP 181178 041-021-67 2"INSULATION PER CONTRACTOR FINAL GRADE=99.14-99.29 TOP OF TANK ST1 ST2 AT INLET=95.95 o TOP OF TANK AT OUTLET=95.91 INVERT OF BUNG NEW 2000 GALLON STEEL AT INLET=95.34 SEPTIC TANK INVERT OF BUNG AT OUTLET=95.11 V V TI-I#6(AFTER INSTALLATION FOR NORTH-WEST SOUTH-EAST TI-1#5(SUBMITTED GW MONITIORING-ATTACHED) • FINAL GRADE=98.76-99.04 • FINAL GRADE 99.18-99.25 WITH DESIGN) ORIGINAL RADEHIGHEST HIGHEST — — ORIGINAL GRADE @ POINT=99.17 HIGHEST POINT=99.17 _ =ILTER FABRIC Al FILTER FABRIC ' • INVERT OF PIPE=94.19INVERT OF PIPE=94.25 ,. ', . "4,,'n Se "sx ii iiiiil.iii 9.15 FEET -4, -4. '4, ,. -,-. ,.. -4, ,. 9.13 FEET ° '' ti`s • 'n ' -4,, ti BOTTOM OF TRENCH=85.04 BOTTOM OF TRENCH=85.12 • ° E 1 18.3+FEET ° RELATIVE ELEVATION @ BOTTOM OF RELATIVE ELEVATION @ T.H.=80.17(T.H.DRY ON 3/1412019) BOTTOM OF T.H.=78.17 (T.H.DRY ON 3/28/19) .iii&S\\\ 111 ..111liq .4 GROUP Ltdrl • ••'�� • GARNESS ENGINEERING 9 • ENGINEERING a SALES=.CONSULTING -- ----. �' 00 3701 E.TUDOR ROAD.SUITE 101•ANCHORAGE.AK 99507•PHONE(907)3378179•FAX(907)3393248'WEBSITE wore gemessengneemg<om •: 0 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ,0�2� •a/ -y • Game.s CHAD HUFFORD 907-727-7198 3 OF 3 •.C'<r% CF-7° . 4= LEGAL DESCRIPTION: DRAWN BY: F �� ,• � �� NEAR POINT KNOLL S/D; BLOCK 2, LOT 18A D.J.G. •• D••• • \- • TYPE OF WORK: DATE: LICENSE 111;PROFESS 44 SEPTIC TANK AND DRAINFIELD PROFILE 3/29/2019 #AECC884 N g L, mo i! ' *•# GARNESS ENGINEERING GROUP, Ltd V-' . . •• ENGINFFRING SALES CONSULTING / 0 3701 E.TUDOR ROAD.SUITE 101•ANCHORAGE.AK 99507'PHONE 19071 3375179'FAX)907)3343248'NE8SITE www 9amrsr.9"•,.^5 com ,E .�• - 7""---,...,_ 0 • � - ey A. me s .11.,4j: SOIL LOG - PERCOLATION TEST �.�',4 C 79 3 ,1. . N LEGAL DESCRIPTION: NEAR POINT KNOLL SID,BLOCK 2,LOT 18A .. ? ZO IG�,.�•t` . PERFORMED FOR: CHAD HUFFORD DATE: 3/16/2019 4 PROFESS\1�4 DEPTH #AECC884LICENS 11,%%SS** (feet) ■ •'.-"- . TEST HOLE #1 1 — • --''° FILL-GM/GP MATERIAL • r7`` WITH SOME ORGANICS AT2-3 FEET SITE PLAN r ` �-; SOIL CLASSIFICATIONS 2— •it;: ':- o' GW ORG , GP j ML • • lfr4 GM Jj� CL • GC ��� OL S • ■ • o°0o% SW /)) MH 5 ■ ■ ;:•••%., SP CH �� • r ; t• • SM ' ,</, OH Q • • S �e G i es 7 — r DEPTH TO Q- • • GROUNDWATER DATE �� N r Gj 8 • DRY 3/16/2019 r • ✓ DRY 3/28/2019 I SCALE: 9 • r 1,M 1.,=100 r ■ • 10 — r • • r DATE READING CLOCK NET TIME WATER LEVEL NET DROP 11 — r TIME (MINUTES) READING (INCHES) ■ r • 12 — r ■ ■ • 13 — r ■ I • 14 — ✓ ■ ✓ ■ 15 • r r 16 — • ■ ■ ■ • 17 r r • r 18 ■ ■ r • PERCOLATION RATE - (MIN./INCH) PERC. HOLE DIA. - (INCHES) 19 • • TEST RUN BETWEEN - FT. AND - FT. I ■ 20 — • r A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES ❑ NO ✓ r 21 B.O.H. SOILS LOGGED BY: DAVID GARNESS PERFORMED BY GEG, Ltd. I,JEFFREY A. GARNESS, CERTIFY THAT THIS WASP FORD IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. S Zq//q I•'LAI NU. ZUUi—1 b1 NEAR POINT KNOLL SUBDIVISION LOT 18A, BLOCK 2 74,219 S.F. N 89°58'32"E 204.31' • • 1 I I I I I I b I I I CV I I 'n I I I I o .•• I I Co I I O • . • I I si9 z 4 ? o I I •s • � .bc \ 1 1 II iol 43 I <,, w IMI ,..: o � � v to N • c. J I``'I W 53.2' 0 o� IWI •I5o ,6 rt. `r° , e 1 0 I O I b O °' 88.0' I M INI ` 0 'i6 l I I Z I I I !o. I I o iNa I I *s , o . � 50� v I I �? N .°' G�` N I I 7 M I ICzt I I r Co ° F.Nj I I o =° z I I I 1 "=50 BUILDING DETAIL 1 I ' ♦- opWE�� Rpp�US_ - - - - _ ` I I I o SCALE: 1"=20' 2.0°. I\ 1 I m I I I ' / N / I I I / I I 'n i e / I I� I� $ / 1 I 1 .Z N 89°58'32"E 221.64' b 50' RADIUS BE b D ') AUTOMATICALLY VACATOED W WHEN STREEETnIS EXXTENDED M SHIVALIK DRIVE AS - B U I L T i HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO .,`�,, GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. o OF '� SURVEYING. LLC IT IS THE RESPONSIBILITY OF THE OWNER TO .4 , AL • JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS. •A_• •�'•�`Sif-#• • 2000 E. DOWLING RD.. SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT = *;• 49TH ANCHORAGE. ALASKA 99507 APPEAR ON THE RECORDED SUBDIVISION PLAT. �.• PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA • 01.•�.�J. .... •/ GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR • 1 . Jeffery A. Gostold • o ar ESTABLISHING BOUNDARY OR FENCE LINES. • s / 2/201 • 44.E 3/22/2019 ; � � SW2043 3/22/2019 ..PPa.••.,•••••.••' a5° ANCHORAGE RECORDING DISTRICT, ALASKA F.B. JOB NO. NOTE : NO CORNERS SET THIS DATE •�41111111111 5 ** 18-04 NPK182 MUNICIPALITY OF ANCHORAGE Ori -Site water & Wastawater Prog:pa�°^ PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Dit System.%V Permit Number: OSP181178 Work Type: Septic Initial Tax Code Number: 04102167000 Site Legal Address: NEAR POINT KNOLL BLK 2 LT 18A G:2043 Site Mailing address: 10565 SHIVALIK CIR, Anchorage Owner: HUFFORD CHAD & TIFFANY Design IEr.gineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: "_effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 7/13/2018 7/13/2019 74219 2 Disposal Field L1 Septic Tank ❑ Holding Tank. ❑ Privy ❑ Private Well ❑ Water Storage All construction shale be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Sroecial Provisions: 0 1. The location of the pre -2008 septic field is unknown. If, during construction, the field is located, construction of the system will stop and a design change submitted to On -Site for review and approval. 2. Provide the well decommissioning log for Inspection Report approval. toAll G 5 k' - [v 0, Received By: Issued By:400 r. Date: Date: s000PA"tr0 MUNICIPALITY OF ANCHORAGE menr � ' On-Site Water&Wastewater Program �o ,,^ j• r -bo-bole. t PO Box 196650 4700 Elmore Road ` t Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 r. .%..C1.)! http://www.muni.org/onsite epartmcnt 4acHOR On-Site Wastewater Disposal System Permit Permit Number: OSP181178 Effective Date: 7/13/2018 Work Type: Septic Initial Expiration Date: 7/13/2019 Tax Code Number: 04102167000 Site Legal Address: NEAR POINT KNOLL BLK 2 LT 18A G:2043 Site Mailing Address: 10565 SHIVALIK CIR, Anchorage Owner: HUFFORD CHAD &TIFFANY Lot Size in Sq Ft: 74219 Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 6 This permit is for the construction of: 0 Disposal Field 0 Septic Tank ❑ Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. A sieve analysis is to be provided when the 24 hr notice is made. 2. The casing is to be brought above grade prior to Inspection Report approval. Received By: "K'tf: 74e.14-efit Date: 7 f U Issued By: ,1--/.€20-6/ ,....7,, Date: /3/'' Lucnr S. Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997 http://www.muni.orq/Onsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV181178 COSA#: Permit#: OSP181178 PID#: 041-021-67 Legal Description: Near Point Knoll B2 L18A Engineer: Garness Engineering Group Applicant: Chad Hufford Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance is 35.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: 74$/ Approved by: kfl-' U(/( Name of Review **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHO : '7� Community Development Department �' one: 907.343-7904 Development Services = • ax: 907- 343-7997 On-Site Water & Wastewater Program Mayor Dan Sullivan 01 5 8 L 9 ti On-Site Sewer/Well Permit Application For A Single Family Dwelling Parcel I.D. 041-021-67 Property owner(s) CHAD HUFFORD Day phone 907-727-7198 Mailing address NHN SHIVALIK CIRCLE*ANCHORAGE,AK 99507 Site address NHN SHIVALIK CIRCLE`ANCHORAGE,AK 99507 Legal description (Sub'd, Block& Lot) NEAR POINT KNOLL: BLOCK 2,LOT 18A Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 6 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: (®all that apply) Initial Absorption Field ® ® Single Family (SF) (w/wo ADU) Septic Tank ® Upgrade CIDuplex (D) ❑ Renewal ❑ Holding Tank ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage n THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: DRAINFIELD TO SLOPES>25%: NO SIEVE ANALYSIS/SAND FILTER Distance: 35 FEET I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP,Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: 5V1.Ot Waiver Fees: 215,00 n p Date of Payment: (5I .8 r Date of Payment: 1 ( 51101 0 Receipt Number: I 1118 014-74 1 1� Receipt Number: (?809 I Permit No. OS r 12 I I `8 Waiver No. OSV I gI D D (Rev.01111) Ouanics • GARNESS ENGINEERING GROUP, Ltd "d"'M`°T. ert Ystt " c mar..! ENGINEERING>SALES•CONSULTING De June 26TH, 2018 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Proposed Septic System for Near Point Knoll S/D; Block 2, Lot 18A To whom it may concern: The existing lot is vacant. Per conversations with the owner, he would like to build a 6- bedroom home (see attached plot plan). There is an existing private well on property that will be used to serve the proposed structure. In 2002 a design was submitted to and approved by the MOA for a 4-bedroom home. We are proposing to utilize the existing testhole data and redesign a 6-bedroom tank and drainfield. We are proposing to install a new 2000-gallon steel septic tank and deep trench type drainfield. Four (4) testholes were excavated on the lot and the proposed drainfield is designed around T.H.#3. It should be noted that a site visit was made by GEG employee David Garness on 6/18/2018 and all four (4) testholes were located. Testhole #1 and #4 appeared to be pinched/non- fuctional while testholes#3 and #2 went approximately 14.5-15 feet below grade and both were dry. Comments regarding the design are summarized as follows: 1. SOILS: See the attached soil logs (from MOA records) which shows the soil classifications, groundwater monitoring, and the percolation test results. As stated on the 2002 design (that was approved), the in-situ soil, visually rated as GM, should act as a sand filter and a deep trench type system should be allowed to be installed. We ask that a special provision be issued with the permit requiring that the MOA inspect bottom of trench to allow for the absence of a sand filter or sieve analysis. We feel as though this is a unique case in that it was previously approved, however, the new code has been implemented since that time which would require an sieve analysis. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: There are no surface water concerns. 4. TOPOGRAPHY/WAIVER: As can be seen on the attached design drawing, the average topography around the proposed drainfield is less than 10%. However, there are slopes greater than 25% less than 50 feet from the proposed drainfield. We are requesting that your department issue a variance from the required separation of 50 feet down to 35 3701 East Tudor Road, Suite 101 *Anchorage,Alaska 99507-1259 Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com Page 2 of 2 feet for slopes >25%. Justifications for granting this waiver are as follows: • This waiver was previously granted for the 2002 design. • The soil has a high porosity; is likely that vertical migration will take place at a greater rate than siltier soils. • The slope is heavily vegetated; it is less probable that effluent would daylight or erode the steep slopes We are unaware of any adverse impacts this installation and/or waivers would have on adjacent wells or septic systems. If you have any questions, please contact us at 337- 6179. Thank you,for your assistance. Sinter.ly, S. Je e A 'e ; ,ess, ".E., M.S. Presi. - n, 3701 East Tudor Road, Suite 101 `Anchorage,Alaska 99507-1259 Phone: (907)337-6179*Fax:(907)338-3246*Website:www.garnessengineering.com N-.................. CAMPBELL CANYON;TRACT B VACANT NEAR POINT KNOLL; TRACT Al CSEPTIC ARE VACANT VACANT LOT 20,BLOCK 2; CAMPBELL CANYON;TRACT A NEAR POINT KNOLL S/D Q EXI,'st+-ng Sefl-ft, Sys co I I I SERVED BY A COMMUNITY \,•- IiWATER SYSTEM I " ? I CAMPBELL 0= I CANYON; ` LOT 1 Cr r - I COMMUNITY 2 . ,,, WATER 3 i . 0\` —• �{► SERVED BY A COMMUNITY / * •.•i:.'.. N /�+ WATER SYSTEM 4.� ,r• t1 co G , IF rg m i I ! O�? CSEPTIC 1 I I GI/- ARj i1i t- / � LOT 19,BLOCK 2; I, M 0 a NEAR POINT KNOLL S/D! // 'V ______. er„ !' � z iie II II \\ SHIVALIK DRIVE LOT 17,BLOCK 2; / \ NEAR POINT KNOLL SID ,' \ / \ / \ 0C (44 a�Pco 1+ - 200'CLASS"A"WELL RADIUS N I I 1 1 1 / S ALE: 1 \ 1"=100' \ / \k / 114 44. • tao.. .0 '... v t GARNESS ENGINEERING GROUP, Ltd • . . '41r... • _ • • 3701 E.TUDOR ROAD.SUITE 101'ANCHORAGE,AK 99507'PH4V4E(907)337-6179'FAX(907)338-3246'WEBSITE'www.gamessengineenng.corn .. . / PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0 cc\% 4 . -; ess : 1CHAD HUFFORD 1 OF 2 ��G�J, E-7953 °�_� PROJECT/LEGAL DESCRIPTION: DRAWN BY: 0. •• bl ?�.�1 .•.(`�. NEAR POINT KNOLL S/D; BLOCK 2, LOT 18A D.J.G./L.K.B. ..(<1) �.....••... ••• .-�.• TYPE OF WORK: DATE: 11EJ.�, 44 SEPTIC SYSTEM DESIGN UPGRADE 6/26/2018 #AECC8134 ,�������� NOTE: THE CONTRACTOR SHALL HAVE THE WEST LOT LINE FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION LOT 20, BLOCK 2; NEAR POINT KNOLL S/D PROPOSED DUAL TRENCH TYPE DRAINFIELD DESIGN CRITERIA: NUMBER OF BEDROOMS: 6 GALLONS PER DAY (GPD): 900 PERCOLATION RATES: <1 MIN/INCH PROPOSED APPLICATION RATE: 1.2 GPD/FT' MINIMUM DRAINFIELD SQ.FT.: 750 FT' DRAINFIELD DESIGN: MAXIMUM DEPTH: 13 FEET WIDTH: 2.5 FEET LENGTH: 30 & 30 FEET EFFECTIVE: 9 FEET ACTUAL SQ.FT.: 1080 FT' RESERVE SITE DESIGN CRITERIA: NUMBER OFBEDROOMS: 6 GALLONS PER DAY (GPD): 900 'PERCOLATION RATE/S: <1 MIN/INCH PROPOSED APPLICATION RATE: 6.0 GPD/FT' MINIMUM DRAINFIELD SQ.FT.: 150 FTI 'SEE ATTACHED SOIL LOGS FROM MOA RECORDS RESERVE DRAINFIELD DESIGN: MAXIMUM DEPTH: 10.5 FEET WIDTH: 2.5 FEET LENGTH: 10 FEET EFFECTIVE: 8 FEET ACTUAL SQ.FT.: 160 FTI co 7�t 50' OFFSET OF SLOPES GREATER THAN 45% FLOW -SPLITTER TO BE EXTENDED ABOVE GRADE PROPOSED HDPE SINGLE COMPARTMENT 1060 INFILTRATOR SEPTIC TANK; INSTALL DOUBLE CLEANOUTS AFTER TANK PROPOSED HDPE SINGLE COMPARTMENT 1530 len `� MIFILTRATOR SE TIC T AND AFTER TDOUBLE CLEANOUT M 10'+ C 4 1 �INSTALLFCO �p 18FEET T. .#5 CO ��� % \ T C T T` 'FROM ALL DECK POSTS PROPOSED 6 A a \ BEDROOM HOME d • - v G .a a- A vd . .0 e .a ' Qv • I EXISTING WELL TO BE DECOMMISSIONED PER UPC; PER CONTRACTOR, THE PROPOSED HOME WILL BE CONNECTED TO PUBLIC WATER a A ---I I TER i ATE SITE GARNESS ENGINEERING GROUP, Ltd 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 • PHONE (907) 337-6179 -FAX (907) 338-3246 - WEBSITE: www.gamessengineering.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: CHAD HUFFORD 205-937-2231 2 OF 2 PROJECT/LEGAL DESCRIPTION: DRAWN BY: NEAR POINT KNOLL S/D; BLOCK 2, LOT 18 D.J.G. TYPE OF WORK: DATE: �., SEPTIC SYSTEM DESIGN UPGRADE 8/22/2018 ---I I TER i ATE SITE ldwlff /I Lai 7T7d \mac GARNESS ENGINEERING GROUP, Ltd - _ — - FNIGINFFRING j SAI FS . ONSI 11 TING 3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507' PHONE (907)337-6179 - FAX (907) 336-3246' WEBSITE v .gamessengmeenng tom SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: NEAR POINT KNOLL S/D; BLOCK 2, LOT 18 PERFORMED FOR: CHAD HUFFORD DATE: 8/21/2018 DEPTH .� (feet) TEST HOLE #5 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 SOIL CLASSIFICATIONS DATE GM AND GP - FILL FROM 8/21/2018 FOUNDATION EXCAVATION 8/29/2018 GW ORG (NATIVE MATERIAL «�= GPML GM CL GC OL SW MH SP CH SM i i OH SC GM WITH LENSES OF GP (AROUND 4.5 FEET AND 17 FEET APPROX. 1 FOOT IN DEPTH EACH) DEPTH TO GROUNDWATER DATE DRY 8/21/2018 DRY 8/29/2018 ITE PLAN �! Q G� N SCALE: 1" = 100' DATE READING CLOCK I NET TIME I WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 8/21/2018 ABSORBED 5 GALLONS AS FAST AS IT WAS INTRODUCED 19 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA B.O.H. TEST RUN BETWEEN 5.5 FT. AND 6 FT. 6 (INCHES) 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES N NO SOILS LOGGED BY: DAVID GARNESS PERCOLATION TEST PERFORMED BY: DAVID GARNESS COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: zq11 0 i Georye P.1Vuerck, Mayor April 15, 2003 municipality of Anchorage Ashok Rai 2751 Debarr Rd. #3328 Anchorage AK 99508-2962 Bailciing Safety Division Subject: On -Site Water and/or Wastewater Permit. Permit Number: SW020135 Legal Deseriptiun::Near Point Knoll Block 2 Lot 18 Dear Ashok Rai: Anchorage All -America City 2002 An On -Site Water/Wastewater Permit, number SW020135, issued by this office for a single-family system, will expire on May 30, 2003. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit for a second year may be issued for a fee of $100.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are: $400.00 for a wastewater permit and $150.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincer Ja s Cross, P.E. Manager On -Site Water and Wastewater Program Enc: Copy of permit P.O. Box 196650 • Anchorage, Alaska 99519-6650 Telephone: (907) 343-S301 e Fax: (907) 343-5200 4700 South Bragaw Street • Anchorage, Alaska 99507 http://Nx xx v.ci.anchorage.alc.us MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SW020135 Legal Description: NEAR POINT KNOLL BLK 2 LT 18 Design Engineer: 0041 AK Water & Wastewater Consultan• Owner Name: Ashok Rai Owner Address: 2751 Debarr Rd #6328 Anchorage , AK 99508-2962 Date Issued: May 30, 2002 Expiration Date: May 30, 2003 Parcel ID: 041-021-59 Site Address: Lot Size: 86814 SQ. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: I] Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy All construction must be in accordance with: 1. The attached approved design. ❑ Private Well ❑ Water Storage 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: Date: '5- $O OZ Municipality of Anchorage • '� Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 041-021-59 Permit Number SW Z 4/3S Property owner(s) ASHOK RAI Day phone 222-0905 . .MailingRII IIIIPIIa�-K19L5J 1� E:l8��g gi �u- :• �U-si�-N� �• � � __'-' _..M Mailing address (2) IIIIIFAMYRZ- •: Legal description (Lot, Block & Sub'd.) L 18- BLOCK 2: NEAR POINT KUQLL SUBDIVISION Legal description (Section, Township & Range) N/A Lot Size ��. �%� Acres q.Ft Number of Bedrooms 5 THIS APPLICATION IS FOR: Sewer Only Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. ALASKA WATER & WASTEWATER CONSULTANTS INC. Permit Fees: `F' q c)c !�" Date of Payment: 6 ^ � a (-) o) Receipt Number: clan ae: Waiver Fees, Date of Payment: Receipt Number: May 13, 2002 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragraw Drive P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Proposed Septic System for Lot 18, Block 2, Near Point Knoll Subdivision To whom it may concern: The proposed 5 bedroom house will be served by a private well and septic system. A well has been drilled on the property at an unknown date. Attached is a well test that was performed by Aarow Pump & Well Service. Four test holes were excavating on the property. The proposed septic system will be designed around the 30 foot radii of these test holes. We are proposing that a 1500 gallon septic tank and also a deep trench type drainfield be installed. Comments regarding the proposed design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. It is our opinion that due to the overall appearance of the soils, an application rate of 1.2 gallons/day/fe should be used and that the insitu silty soils should acts as a sand filter. 2. TRENCH DESIGN: a. Percolation Rate: <1 minutes/inch b. Allowable Application Rate: 1.2 gallons/day/fl? c. Number of Bedrooms: 5 d. Design Flow: 750 gallons per day e. Minimum Absorption Area: 625 fl? f Total Depth: 10.5 feet (max.) g. Effective Depth: 6 feet h. Width: 2.5 feet i. Reduction Factor: N/A j. Minimum Length: 55 feet total length k. Effective absorption area = 660 82 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed upgrade. 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com 4. TOPOGRAPHY: As can be seen on the attached topography site plan, the average topography in the area of the septic system is generally flat. There is a slope that exceeds a 25 percent slope north of the proposed septic system. We request that the required 50 foot setback from this slope be waived to 35 feet. Given the porosity of the soils and the heavy vegetation on the slope, there is minimal risk with the granting of this waiver. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your M.S. NOTE: Attached is a site plan drawing, a design drawing, a topography site plan, four soils logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com Sent by:AAROW PUMP AND WELL Dec -25-01 09:57am from 90733389764907 338 3246 page 1/ 1 WTERWELL TEST PL' MIP RLEPOIff Conducted 6ys ti A f'ue- U, C- O*tler: •Ur, Aidress: WeHLoallon: iic�'eyai..t{?igkFr QeS-'• wo) T»fmm,al,nr' r� Crrron From ---Tp 'rrttalT.��th• s13 S flr'PNI �°E'"aing• ['�_ C'ssimg See: �' � _ ^exsa i)isssr Scrtecst �3rst: `—.— Remarks rami, wormabon Sw tf G 150.k... air Line 8eatb: rnsak water °� ? 5 GPM, Max Dravwsvrn: �^ Sfiattc water Lere�: 1�� Av. D�eksr�t: � _ Yumpou �te �2-a0 01 PtmWO Time: `t_ o�O'b _Date: ja � Time: la•oU py --_ Time water Flow Remarks Level GPM (t0. .y eve( c�a5 Mwa 0w kA ,JA tiry tir [,Ja U QVw ed -For i ke few-eiNI �n� ti uti e M. wt if 6� to er_t'e4e'_ �! �\ \ TRACT Al. \ NEAR POINT KNOLL S/D 1 ,1 RL 1 1 LOT 20, BLOCK 2; NEAR POINT KNOLL S/D i SERVED BY A COMMUNITY 1 WATER SYSTEM 1 0 1 1 1 I I I c�I 1 PROPOSED TH4 I 5 BEDROOM I • (IA I I i PROPOSED SEPTIC SYSTEM �Y ' 1 HOUSE----_I I I (SEE DESIGN, PAGE 2 OF 5) ,�.. J1• '„ i ,� 111 Lli / ..,.,x•'i. I 1 1 0 11 1 1 1 1 I 0 y 1� 11 lL II AL RN ATE SITE m 00 111 m Y v EXISTING ?�• I' III I/ I I In z ' 1 LOT 19, BLOCK 2; WELL a 1 1 NEAR POINT KNOLL S/D { •'V' •"T`F.( EXISTING TEST HOLE BY H.H. WILSON, P.E. ___` I>G�— 1 \ 112 I I I 1 e��aO I I i I I I 200' CLASS 'A' WELL RADIUS a�4 i LOT BLOCK 2; I I I I I 1 POINT NEAR POINT KNOLL S/D 11 i I I I I I I I I / 1 5/13/2002 `•'" . DRAWN BY: ALASKA WATER &WASTEWATER uwrlu.,aawacunama+ mmsarmwu,mnmrn CONSULTANTS INC ^N°""' ..1 SCALE.'J.L.M.4*'+f/ n o 100r r ....:.. ... ... ......... rn 6901 DESARR ROAD. SUITE 20 ' ANCHORAGE, AK 99504 PHONE (907WN7-6179' FAX (907)358-3246 n PREPARED FOR PHONE NUMBER: PAGE NUMBER: ii. .... ..... .... ... ........ 24' 1% ASHOK RAI 222-0906 1 OF 2 J T Garness: y+1 7953 m` V LEGAL DESCRIPTION:U"19/ NEAR POINT KNOLL SUBDIVISION; LOT 18, BLOCK 2 P�ofesslo�°: TYPE OF WORK: SITE PLAN FOR PROPOSED, SEPTIC SYSTEM I - PROPOSED 1500 GALLON SEPTIC TANK I: INSULATE UNDER DRNEWAY WITH 4 INCHES OF BLUE - BOARD BY 4 FEET WIDE. . TOP OF SLPPE +'.e" INSTALL FOUNDATION CLEANOUT I STALL DOUBLE CLEANO <• C I I i„ 4• I n • I S I I N ul -10a 7%,03 0 .. ;. .. .' TH 4 o I I TH 2 O :48.5, ; "0 II I I �I I TH#1 4 n it I I I /I ALTERNATE SITE. WILL REQUIRE t'• •a• I I I THE USE OF AN ADVANTEX UNIT.. PRAOTRENCH THAT D DRAI Fl SI OE. E5 FEETE DEEP MAXIMUM BY 2.5 FEET WIDE BY 55 FEET LONG. ADD 6 FEET OF :. CLEAN, WASHED SEWER i i INRI CK. II EXISTING I ( I WELL A.' I� ` /I EXISTING TEST HOLE \ BY H.H. WILSON, P.E. I = I w I �� i i� 10IoIO - DATE: 5/13/2002 �k n BY: .Ra DRAWN ,.�,•_ ALASKA WATER & WASTEWATER J.L.M. SCALE: CONSULTANTS, INC. _ 1" — 40 .• .... .•. •.. ....D 6901DEBAR ROAD, SUITE28' 4NCHORAGE AK 99504' PHONE (907)337-6119' FA%(90])338-3246 PHONE NUMBER: PAGE NUMBER: .. .... .. .. .... .........� PREPARED FOR: ASHOK RAI 222-0906 2 OF 2 r y A. Garss:' QO�� s -. E 7953 •.'`Fw� 4o�Dro O40OgAo LEGAL DESCRIPTION: .' NEAR POINT KNOLL SUBDIVISION; LOT 18, BLOCK 2, TYPE OF WORK: DESIGN OF PROPOSED SEPTIC SYSTEM pUIL°`LUb LEGAL DESCRIPTION: NEAR POINT KNOLLSOT 18 BLOCK 2 PERFORMED FOR: ASHOK RAI DATE: 4/11/2002 DEPTH (feet) ITEST HOLE #1 10-1 11 SILTv RAVEL 12 DEPTH TO DATE GROUNDWATER DRY 4/11/2002 DRY 5/13/2002 Je e Garness: OQ049j C7953 �G �4t0. ........... •' ��qv4 WQ\-pro fessio�0oo 0ll 0l I PROPOSED 5 BEDROOM I HOUSE :�?:`..r; THN4 PROPOSED j� SEPTIC SYSTEM I i i r#2 I qTH#1 Ij ALTERNATE SITE I�'• I I I EXISTING .t, I� WELL i SITE PLAN EX�$T NG HOLE \\ 1 -100 BY H.H. W LSON, P.E. DATE READING CLOCK NET TIME (MINUTES) WATER READ NG EL y MSOIL CLASSIFICATIONS. N SPS PpO N LARGE GRAVEL -- •- S� SFP WITH SILT - 111111111 GL OR��O MCL �I\\IZpp2 PgS GM 1 it M gin'GCOL • MH Vr -SM MOH CHSC ` 10-1 11 SILTv RAVEL 12 DEPTH TO DATE GROUNDWATER DRY 4/11/2002 DRY 5/13/2002 Je e Garness: OQ049j C7953 �G �4t0. ........... •' ��qv4 WQ\-pro fessio�0oo 0ll 0l I PROPOSED 5 BEDROOM I HOUSE :�?:`..r; THN4 PROPOSED j� SEPTIC SYSTEM I i i r#2 I qTH#1 Ij ALTERNATE SITE I�'• I I I EXISTING .t, I� WELL i SITE PLAN EX�$T NG HOLE \\ 1 -100 BY H.H. W LSON, P.E. DATE READING CLOCK NET TIME (MINUTES) WATER READ NG EL NET DROP (INCHES)TIME SPS PpO P S� SFP OR��O �I\\IZpp2 PgS PERCOLATION RATE <1 (MIN./INCH) FERC. HOLE DIA. 0 V CJj 19 TEST RUN BETWEEN 6 FT. AND ____Z_FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO SOILS LOGGED BY: JASON WOOD PERCOLATION TEST PERFORMED BY: JASON WOOD COMMENTS: THE INSITU SILTY SOILS SHOULD ACT AS A SAND FILTER. PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS P RFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE :1 2- AT .ASKA 2 PERCOLATION TESTI LEGAL DESCRIPTION: PERFORMED DEPTH t) FOR: NEAR PUINI KNULL J/U' Wi 10, own c ASHOK RAI DATE TEST HOLE DRY 5/13/2002 SOIL CLASSIFICATIONS 2 SEPnc GM SYSTEM LARGE GRAVEL b„=o� GW ORG TH z WITH SILT GP ML 3 GM CL pOE- Pc� P GC OL 4 SW MH II SID CH 5 d l SM i OH i lI I EXISTING 6SOR�� SC 6 SITE PLAN HOLE 7- 8- 9- 10. 11 12 13 14 15 16 17 18 GM SILTY GRAVEL DEPTH TO GROUNDWATER DATE DRY 4/11/2002 DRY 5/13/2002 PROPOSED I I � � PROPOSED CLOCK TIME 5 BEDROOM WATER LEVEL READING HOUSE '- TI{#q PROPOSED SEPnc SYSTEM TH z jib: s � •Ip I I I I pOE- Pc� P i t ITH 1 Pct'( PS F II ALAI RNATE SITE II d l q �\ i lI I EXISTING 6SOR�� WELL JI I SITE PLAN HOLE \ EiknW \ 1 -100 BY H.H. WILSON, P.E. DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) pOE- Pc� P Pct'( PS F p�P 6SOR�� P �I\\IZpp2 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 6 FT. AND 7 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO SOILS LOGGED BY: JASON WOOD PERCOLATION TEST PERFORMED BY: JASON WOOD COMMENTS: THE INSITU SILTY SOILS SHOULD ACT AS A SAND FILTER. PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS ER ORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: r 1 bZ rA ISVIL LVIi — rtrtwu�llvi. iwii LEGAL DESCRIPTION: N�+R POINT KNOLL S/D• LOT 16, BLOCK 2 PERFORMED FOR: ASHOK RAI DATE:_ DEPTH HOLE #3 (feet) TEST E w GM 101 �I I I II SILTY RAVEL 12 13 14 15 16 17 18 DEPTH TO GROUNDWATER DATE DRY 4/12/2002 DRY 5/13/2002 19 TEST RUN BETWEEN PS p0 F pS� • •LARGE 20 A FOUR HOUR PRESOAK WAS PERFORMED: R pS Pgc'OR��O SOILS LOGGED BY: JASON WOOD PERCOLATION TEST PERFORMED BY: JASON WOOD COMMENTS: THE INSITU GRAVEL SAND FILTER. G INC. I, JEFFREY A. GARNESS, ORGWITH WASP FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 02� SILT GP MLGM /N, CL 111ilul • "%/!%SIM.�•11 SC E w GM 101 �I I I II SILTY RAVEL 12 13 14 15 16 17 18 DEPTH TO GROUNDWATER DATE DRY 4/12/2002 DRY 5/13/2002 19 TEST RUN BETWEEN A. 12/2002r I�OQ04^eE 7953 PROPOSED 5 BEDROOM I HOUSE TH4 PROPOSED SEPTIC SYSTEM TH#2 i,gTH#1 'I 7'fjN TE SITE EXISTING i 1 \ WELL ✓i I \ SITE PLAN(ynN� HOLE \ 1"-100 BY H.H. WILSON, P.E. DATE READING CLOCK NET TIME WATER LEVEL TIME (MINUTES) READING NET DROP (INCHES) <1 (MIN./INCH) FERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN PS p0 F pS� 7 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: R pS Pgc'OR��O SOILS LOGGED BY: JASON WOOD PERCOLATION TEST PERFORMED BY: JASON WOOD COMMENTS: THE INSITU �I\2j2pp2 SAND FILTER. PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WASP FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: PERCOLATION RATE <1 (MIN./INCH) FERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 6 FT. AND 7 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO SOILS LOGGED BY: JASON WOOD PERCOLATION TEST PERFORMED BY: JASON WOOD COMMENTS: THE INSITU SILTY SOILS SHOULD ACT AS A SAND FILTER. PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WASP FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 02� LEGAL DESCRIPTION: NtAK ruINI N V" 0(1. ��I 1 PERFORMED FOR: ASHOK RAI DATE: 4/12/2002 DEPT (1eet� ITEST HOLE P 7 9—ilLlIIri11 10 11 —{1 I SILTY RAVEL 12 13 14 15 16 iu DEPTH TO GROUNDWATER DATE DRY 4/12/2002 DRY 5/13/200It2 MSOIL CLAS 1FICATIONS w GM S PO M LARGE R F PSN R PS \NPNE �SORS�O PS \ •. MWITH P . 11111!1111 y M II I IJI CIL HONE . IL nm n1MH woo _ 7/70/,.cH N N 1�l1�t3� • r «t!SC 7 9—ilLlIIri11 10 11 —{1 I SILTY RAVEL 12 13 14 15 16 iu DEPTH TO GROUNDWATER DATE DRY 4/12/2002 DRY 5/13/200It2 I 1 1 1 PROPOSED 5 BEDROOM HOUSE ,s; TH#4 PROPOSED 1 SEPTIC SYSTEM TH#2 � II II F�L'fERNATE SITE EXISTING 111 I� WELL '.. I �� SITE N HI GI HOLE 111QA.H. WILSON, POE. DATE READING CLOCK NET TIME TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) S PO F PSN R PS \NPNE �SORS�O PS \ P �I\2IT PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 6 FT. AND 7 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO SOILS LOGGED BY: JASON WOOD PERCOLATION TEST PERFORMED BY: JASON WOOD COMMENTS: THE INSITU SILTY SOILS SHOULD ACT AS A SAND FILTER. PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W ER ORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: i \y i •.I e e MIN C) LLJ�• .. ' ' • `• • 111=' : EXISTING TESTWILSON. �r �. • �:'•i�/fit �'ir� � �'�® �•�-• -� GRE .! ,NCHORAGE AREA BORI , ~1]~/ Department of Environmental Quality ~ 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE ~ ~ ,.['.~1^ NUMBER OF FROM WELL f J MANUFACTURER '~"~'vt~)~. '~- MATERIAL VI~)'~/'"'~W'~5' COMPARTMENTS INSIDE LENGTH '-- INSIDE WIDTH ~ LIQUID DEPTH ~ LIQUID CAPACITY ?..O~ GALLONS. TILE ~ ~ TOTAL LENGTH DISTANCE NE OF LINES FROM WELL NUMBER OF LINES DISTANCE..~E-T, NC~EN LINES ~"'"--T-.~CH WIDTH IN. TOTAL EFFECTIVE ABSORPTION AREA ~SQ. FT. LENGTH OF EACH LINE '"'~"'~~/- H~O~ DEPTH OF FILTER DEPT FINISH GRADE MATERIAL BENEATH TILE IN. ABOVE TILE ~'"~_.......IN. WELL: BUILDING FOUNDATION CESSPOOL . CONSTRUCTION ~:~{,50~o~/~ 0 Oe '%llt ed' t-o NEAREST NEAREST SEPTIC ~ SEEPAGE LOT LINE , SEWER LINE__, TANK ~, SYSTEM DISTANCE FROM: OTHER SOURCES APPROVED __ DISAPPROVED__REMARKS DISTANCES: ~ \( INSTALLED BY: ~ I ~C' SEWER LINE DEPTH: PIPE MATERIAL. LOT SLOPE: REMARKS: A) ~[o DIAGRAM OF SYSTEM G r EA,.~.~.~NCH O RAG E AREA DEPARTMENT OF ENVIRONMENTAL QUALITY 3.0 "C" STREETTELEPHoNEA"CNORA E, ALAS"A''032,4_.6, ' SEWAGE DISPOSAL SYSTEM -- APPLICATION AND pERMIT FINANCED THROUGH -- TO Bg INSTALLED BY COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION, MINIMUM DISTANCES, REQUIREMENTS ~/ DIAGRAM OF SYSTEM FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE p]T SEPTIC TANK TO SEEPAGE PIT WALL SEPT[(:; TANK SEEPAGE PIT TO NEAREST LOT L[NE. p~2 WELL TO SEPTIC TANK DRAIN FIELD SEEPAGE Pit ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK , SEEPAGE PIT DRAIN FIELD SEPTIC TANK, ~ * SEEPAGE PIT ~ ~DRAiN FIELD TO RIVER, LAKE, STREAM. GAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION ~ FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST iRON SIPHON PIPES ON SEPTIO TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDI INSTALLATION. L~6~ATER ANCIIORAGE AREA BOROUGli.~ Department of [nvironmental Quality 3330 "C" Street Anchorage, Alaska 99503 Performed for _~___C~---~ /~-~ /~ ' Date Performed Legal D escrl pt~on: ~~)_~_/¢~J~,_ . .. This form reports: ~i~ log ~ verco~at~on ~est Depth Feet II - 12- 13- 14--~ Was g~ound water encountered? . If yes, at what depth? __ Reading Date Percolation rate Gross Time . Net Time minute. _Depth to W~te____~c Net Drop -Proposed installat-~-~-~ Seepage Pit Drain Field Depth of Inlet . Depth to bottom of pit or trenci~ COMMENTS: ~:~..~_-.~'~---~,~~A/-~]~-~ ~7~7~ Perto~ed By:__~]~. Certified By: ~-T*- Bq-o4o (6/?4) · . 4 .~ o,, o ~ ' oo ',~'--~' .¢'~ z o o