Loading...
HomeMy WebLinkAboutTOWER ESTATES BLK 1 LT 6Tower Estates Block 1 Lot 6 #017-411-31 Unresolved Inspection Report review comments. Not eligible for COSA. Engineer: Legal Description: Permit: Report Type: Municipality of Anchorage P.0 Box 196550 4700 Elmore Road Anchorage, Alaska 99519-6650(907)343-7904 Fax(907)343-7997 httPJtwww.muni.ora/onsite - Planning and Development Services Department On -Site Water and Wastewater Program - On -Site SewerNVell Submittal Comment Sheet DUPLICATE FOR GARNESS TOWER ESTATES BLK 7 LT 6 SW020245 WellSeptic As Built Review Completed By: The attached paperwork has been reviewed and is being returned for the following reasons: 2!28/2014 J.Crewdson 1. Well - Location: The well appears to be in the 33' Section Line Easement. Please remove or provide an encroachment letter allowing it to be then:. 2. Well - Pump Set At: Please note on the inspection report the depth the pump was set at. 3. Drainfield - CONT: It appears the drainfields were constructed such that no cleanouts or monitor tubes extend above the ground surface. Please provide. Ref. AMC15.65.060E12,13 4. Drainfield - Driveway: It appears the drainfields are under the driveway. Please revise. Ref. AMC15.65.060A3 Crewdson, James A. From: Crewdson, James A. Sent: Friday, February 28, 2014 3:18 PM To: 'Jeff Garness' Subject: TOWER ESTATES BILK 1 LT 6 Attachments: CrystalReportViewer[1].pdf Jeff, Deb and I discussed this project and agree it shouldn't be conditionally approved. So I'm issuing the comments and putting a notice on the front of the file that its not eligible for a COSA. Please forward the comments to the owner. ,rystalReportViewei [1].pdf (73... Thanks Jay GARNESS ENGINEERING GROUP, Ltd. mmmoommunnommmm CONSULTANTS & GENERAL CONTRACTORS mmmeemomwommun November 26, 2013 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Rd. P.O. Box 196650, Anchorage, Ak 99519-6650 (907)343-7904 Ref: Permit #S W020245 - Tower Estates Block 1, Lot 6 — Memo Regarding Conditional Approval To whom it may concern: Prior to the involvement of Gayness Engineering Group, Ltd. (GEG), this was a vacant piece of property. GEG completed test holes and a design. A well and sewer permit was issued by the MOA on 7/25/02, and the system was installed by the fall of 2002. We were waiting to be provided the well log, pump log, as - built survey and for the final grades to be completed over the septic area before completing an as -built package. Your department contacted us in 2013 asking about the status of the septic system as -built drawings. To our surprise, we discovered that a house had been built, and that a certificate of occupancy had been issued by the MOA for the property. We then requested an as -built survey from the property owners. This spring we received an as -built survey, and discovered that the septic is sitting under what appears to be a driving surface. Furthermore, the septic pipes are not exposed at grade or visible. It should also be noted that, according to the as -built survey, the well was placed in a section line easement, and the house appears to be sitting in a 10' telecom & electrical easement. If the final grade elevations are to be established on the property, the septic system cleanouts and monitoring tubes will need to be exposed and inspected for any possible damage. Attached are partial as -built drawings. GEG will be available in the future to resolve issues associated with documentation of this septic system on a hourly rate fee basis. It is our understanding that provisions are now in place at the building department to require final approval of septic systems, prior to issuing a certificate of occupancy to avoid 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com Municipality of Anchorage . Development Services Department oc a Building Safety Division — On-Site Water & Wastewater Program, 4700 South Bragaw St, P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW020245 PID Number. 017-411-31 Name:TERRI WHITE Wastewater System: ■ New ❑ Upgrade Address: 6820 EAST 11TH AVE. ANCH. AK, 99504 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 240-3278 3 ❑ Deep Trench ■ Shallow Trench O Bed ❑Mound ❑Other LEGAL DESCRIPTION Soil Rating: 0.6 Total Depth from anginal grads: SEE DWG GPD/Sq. Ft. rt. Block: Lot: Subdivision: - Depth to pipe bottom from original grade: Gravel depth beneath pipe: 1 6 TOWER ESTATES SEE DWG Ft. ** 0.6 / 0.57FL Township: Range: Section: Fill added dome original grads: Grovel length: — — — SEE DWG Ft. 2 ® 75 PL WELL: ■ New [I Upgrade Groel width: 5 Numbero! lines: 2 Distance between line: 15+ Ft, Ft. classification (Private, AB.C): Total Depth: 1 Camtl To: MRS Total absorption are: Pipe material: D 3034/ F-810 PRIVATE 387 Fz 19 FL 750 so. Ft DNller. Data Drilled: 15/23/03 Static Water Level: Installer. Date installed: 8/2-12/2002 ALPINE DRILLING 100 Ft. WOOD & SON EXCAVATION Yield: Pump Sat M: Casing Height Above Ground: TANK 6.0 GPM UNKNOWN n. 2 Ft. SEPARATION DISTANCES ■septic 13 Holding ❑S.T.E.P. ❑Other Ta Septic Absorption Lift Holding Public/Prieta Manufacturer. ANCHORAGE TANK Capacity In gallons: 1250 From Tank Field Station Tank sewer untie Well 100' too'+ — — z5'+ Material: STEEL Number of compartments, 2 Surface Water 100'+ too'+ — — — LIFT STATION Lot Line 5'+ to'+ — — — Slm in gallons: Manufacturer. 7on' level at: amp offump at: High water alarm at: Foundation 5'+ 10't — — — Pump Maks tlel: Dsctrlcal Inspections performed by: Curtain Drain NONE KNOWN Remarks: BENCH MARK ** NORTH TRENCH / SOUTH TRENCH Location and Description: TOP OF S.E. CORNER OF ELECTRIC PEDESTAL -- Assumed Elevation: 106.60 PL ENGINEER'S SEAL Qv60� AKWWC, INC. Inspections performed by: Dates: 1st 8/2/2002 ........... .. 2nd 8/5/2002 0"" ' " ' ' "=" 3rd 8/6/2002 4th 8/7/2002 5th 8/9/2002 6th 8/12/2002( o'' �.J f y Grn as.: Development Services Department Approval O ���� tE 7/ ..c�oQoo �� Reviewed and approved by: Date: 44od o ofeseto�° (Rev. 12/01) I U PERMIT NUMBER: AS -BUILT DRAWING PARCEL ID NUMBER: 807020245 017-411-31 mm FCO 7.41 37.2 ST1 15.49 41.1 ST2 23.06 45.2 DBL1 26.06 47.31 DBL2 27.26 48.68 C01 72.32 84.13 MT1 69.55 82.19 CO2 1 D9.86 143.45 MT2 104.17 137.49 CO3 103.37 140.30 MT3 97.78 134.58 C04 57.23 74.71 MT4 56.16 77.93 SPL 72.60 104.15 NOTE: NO DRAINFIELD PIPES ARE VISIBLE AT GRADE, PER AS -BUILT SURVEY. LOCATIONS ARE BASED UPON GEG SWING TIES. s ::cozy NEW DRAINFIELDS- NEW 1250 GALLON SEPTIC TANK-- •" aa`^ INSTALLED FLOW •�`>� ^ DIVERTER ISI � C 1.C w° C 'of C�S.pp�O w z _ -dI CAR PORI / IEI Orness:- Q s ::cozy NEW DRAINFIELDS- •}}.•"'"s' �.ry .•.�:y7.'' BEDROOM r':• !'� HOUSE ''1. A ,. .r • •: ,'e.v FCO: - 11-'r"/ •. +� "'' ..r •.'• }.1' "I�`d-:;'.'mil T. GARNESS ENGINEERING GROUP, Ltd. o* CONSULTANTS & GENERAL. CONTRACTORS 3701 E WOOR ROM, SURE 101 • @IGHORME. W 99507 . PHONE (907)M7-5179 • FM (907)339-3248 • W UE: www.9am. ngin fln9.wm PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ' TERRI WHITE 338-5251 2 OF 3 ' LEGAL DESCRIPTION: DRAWN BY: Qp9� TOWER ESTATES S/D; BLOCK 1, LOT 6 A.J.G. pyo (TYPE OF WORK: DATE: AS -BUILT DRAWING 12/13/2013 (Rev. 01/05) N IEI E ISI � C 1.C w° C 'of C�S.pp�O w z _ -dI o / IEI Orness:- Q 5 imp .15cc°o o w Ivl w / L 10 H •}}.•"'"s' �.ry .•.�:y7.'' BEDROOM r':• !'� HOUSE ''1. A ,. .r • •: ,'e.v FCO: - 11-'r"/ •. +� "'' ..r •.'• }.1' "I�`d-:;'.'mil T. GARNESS ENGINEERING GROUP, Ltd. o* CONSULTANTS & GENERAL. CONTRACTORS 3701 E WOOR ROM, SURE 101 • @IGHORME. W 99507 . PHONE (907)M7-5179 • FM (907)339-3248 • W UE: www.9am. ngin fln9.wm PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ' TERRI WHITE 338-5251 2 OF 3 ' LEGAL DESCRIPTION: DRAWN BY: Qp9� TOWER ESTATES S/D; BLOCK 1, LOT 6 A.J.G. pyo (TYPE OF WORK: DATE: AS -BUILT DRAWING 12/13/2013 (Rev. 01/05) N SCAL : C 1.C C 'of C�S.pp�O o . .............. CE-. y . Orness:- Q 5 imp .15cc°o I PERMIT NUMBER: AS—BUILT DRAWING PARCEL ID NUMBER: — 550020245 017-411-31 FINAL GRADE = 98.89-99.07 INSULATION TNLETF T96.92T , I (� I _� I LI INVERT OF BUNG - AT INLET = 96.36 NOTE: DRAINFIELD • PIPES CAPPED BELOW GRADE (ASSUMED) FILTER TOP OF SAND —/ 5' = 90.30 (AVG.) BEDROCK AT 84.22-84.27 NEW 1250 GALLON SEPTIC TANK TANK AT = 96.89 INVERT OF BUNG AT OUTLET = 96.09 FINAL GRADES NOT ESTABLISHED AT THIS POINT. DRAINFIELD PIPES MUST BE EXTENDED TO SURFACE LEVEL BEFORE GRADES OVER DRAINFIELDS CAN BE ESTABLISHED GRAVEL DRIVEWAY SURFACEQQ = s5.3a—sl • FILTER FABRIC 2' INSULATION F ORIGINAL GRADE I = 94.81-94.89 INVERT OF PIPE = 95.00 (AVG.) TOP OF SAND = 94.40 (AVG.) I 5 INVERT OF PIPE BOTTOM OF TRENCH = 90.87 (AVG.) 10, = 91.30-92.27 BEDROCK AT —BOTTOM OF TRENCH 187.13-88 40 = 88.80 (AVG) GARNESS ENGINEERING GROUP, Ltd. ---=—�_-*�_ CONSULTANTS & GENERAL CONTRACTORS 3701 E NWR ROAD. SURE 101 - ANCHU E. W 99501 ' PHONE (97)337-6179 • FAX (950)338-3248 WE6511E xxv.gwnwFn9'0FFd09com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: TERRI WHITE 907-338-5251 3 OF 3 LEGAL DESCRIPTION: DRAWN BY: TOWER ESTATES S/D; BLOCK 1, LOT 6 A.J.G. TYPE OF WORK: DATE: PROFILE AS—BUILT DRAWING OF SEPTIC SYSTEM 12/13/201_ (Rev. 01105) 3 CIRCLE. TOWER ESTATE Ul N84 -00%"E 69.30 R=100.000=62.08��\. N6po I 2S63 I w � I 669p \GLEN ALPS ROAD — �Fr°� \se\nrm. e Ery R=280.00 L _ M I ' 182.40 J / Metal ga ll / --r1' Conr block ret_I I wai ice/ ice/ Ui 'e�ey I EI 2 d(N� co, N W ve\ ? I al cn 1q: LOU Q LUW \\ IW) z \\� LOT 6 I EI O \ 10I U W CD III CO ------ I I (\\ I r' I � Gravel partying area � I \ I I Well I +I \ I I . I \ \ 36. ` 3 Story Frame HOUSeI I i —, 2.0 OH I f Foundalion r0 44.0 LOT 5 c- 226 Entry I ,0 63.9 Septic tank co . � \ I v Car Port to I I 00 IIo I 63.9 6 I I qI 1 ravel parking area ----------I-II � II II II II II II II II II II The location of the structure(s)as I I shown on this record drawing (as -built) complies with Title 21, AMC. �- -13 I I BY I I Date: _ II II II SCALE: 1't= 60' EASEMENTS OF RECORD, OTHER THAN I I THOSE SHOWN ON THE RECORDED PLAT ARE NOT SHOWN HEREON. _ --1G" elecofn._&1_7ec-Ease In—q n -- FB 13-3, pg 2- LOT 4, SUN SHINE ACRES N89057'05t'W 158.18 BE 05 t r. I 8381 K TRACT A GONZALES SUBD. ��P�� OF•A��S��,, 49th 00*: j '� 00 •.Fred Walatka. ffi 3255-S� 'RbFrssIONN\- S-13-13 AS -BUILT NO CORNERS SET THIS DATE I hereby certify that 1 have performed a Mortgagee's inspection of the following described property: LOT 6. BLOCK 1. TOWER ESTATES SUBDIVISION Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Anchorage, Alaska this 7th day of May ,2013. FRED WALATKA & ASSOCIATES Engineers and Surveyors (907-248-1666) e m 4 / '�.........._ N t"t1 rwe w+a e9w+sTa *-Wr erte K \ 11r t1 �.M ti i ! 1. li l Q i iD A, V N ■ /-i1{I t17�, Of ts.i 16 fiCY Y { It a/ �7 9a ..sg 17 riw.aw.F wwF wi {..{ww{4L. wti�1 Lt..f..+w.. S'6wwT:w ww l®`�'�`.�L'°'�4'l ala: traa aS'aecaca vT a ea:.:.. a.e as..as . eu+e ea.e. arse r. aa,.G.af \�,�' / �.lV. DUX f7UU:)v h+fU iUiByC flidSiCd �nJiy-<7V:fv Rick Mystrom httolfw .danchoraae.ak.us Mayor Permit Number: #SW 020245 Date of Issue: 6-25-02 Parcel Identification Number: 017-411-31 Date Started: 5-21-03 Date Completed: 5-23-03 is well located at approved permit location? ® Yes ❑ No Legal Description: Tower Estates Blk 1 Lt 6 Property Owner Name & Address: Terri White 6820 East 11th Ave. Anchoraae. Alaska 99504 Borehole Data: Depth (ft) Method of Drilling ® air rotary ❑ cable tool Soil Type, Thickness & Water Strata From To Casing type: steel Stick-up 0 2 Wall Thickness: .250 inches gravelly silt 2 7 Diameter: 6 inches Depth: 19 feet Bedrock 7 387 Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 100 feet Pumping level: 387 feet after 2 hours pumping 6 gpm Recovery Rate: 6 gpm Method of Testing:; puma Well Intake Opening Type: ❑ Open End 0 Open Hole ® Screened Start feet Stopped feet ❑Perforations Startfeet Stopped feet Grout Type: bentonite granules Volume: 1 be Depth: Start 0 feet Stopped ? feet Pump: Intake Depth feet Pttmp size hp Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: chlorine tablets Comments: Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage Alaska 99511 " Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property _ __al _.__11 .l_!11 _f _11 .. _i _1f f_ a_ al. T...a .CTT..IaI. O TT.. .... [\..—.!. ... .._al. •.. //1 .1 _C ... ..1 _a'_.. GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS & GENERAL CONTRACTORS om November 30, 2004 Municipality of Anchorage Development Services Department On-site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, Ak 99519- 6650 Ref: Well and Septic system documentation; Tower Estates Lot 6, Block 1. To Whom It May Concern: The installation of the well and septic system on the subject property was completed on 5/23/03.We are unable to complete the asbuilt documentation until the owner provides us with an asbuilt survey.a owner has been notified of this and will provide us an asbuilt when the house is comple� If you have any questions just give us a call and thank you for your time. M.S. 3701 E. Tudor Road, Suite 101 * Anchorage, Alaska 99507 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: gamessengineering.com George. P. 11'uerch. Mayor June 2, 2003 Terri White 6820 East 11th Ave Anchorage AK 99504 Anchorage Municipality of Anchorage All -America City Building Safety Division 1 I I I I 1 2002 Subject: On -Site Water and/or Wastewater Permit. Permit Number: SW020245 Legal Description: Tower Estates B1k,1 LT 6 Dear Terri White: An On -Site Water/Wastewater Permit, number SW020245, issued by this office for a single-family system, will expire on July 25, 2003. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit for a second year may be issued for a fee of $100.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are: $400.00 for a wastewater permit and S 150.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincer y, Ja es Cross, P.E. Manager On -Site Water and Wastewater Program Enc: Copy of permit P.O. Box 196650 • Anchorage, Maska 99519-6650 • Telephone; (907) 343-8301 0 Fax: (907) 343-8200 4700 South Bragaw Street • Anchorage, Alaska 99507 http://n1�lc.ci.mtchora�e. ¢tk.us d MUNICIPALITY OF ANCHORAGE ?A/0 �P Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: Jul 25, 2002 Expiration Date: Jul 25, 2003 Permit Number: SW020245 Parcel ID: 017-411-31 Legal Description: TOWER ESTATES BLK 1 LT 6 Design Engineer: 0041 AK Water & Wastewater Consultan• Site Address: Owner Name: Terri White Lot Size: 206729 SQ. FT. Owner Address: 6820 East 11th ave Total Bedrooms: 3 Permit Bedrooms: 3 Anchorage , AK 99504 - This permit is for the construction of: D Disposal Field ❑✓, Septic Tank ❑ Holding Tank ❑ Privy E Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 1 BAAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: Date: 7L—?S104 Municipality of Anchorage • ' ` Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 017-411-31 Permit Number 5WOZ0245' Property owner(s) TERRI WHITE Day phone 338-5251 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) TOWER ESTATES SUBDIVISION: LOT 6. BLOCK 1 Legal description (Section, Township & Range) Lot Size 4.75/206.729 Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms 3 Sewer Only ❑ Well Only ❑ Sewer and Well E Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. ALASKA WATER & WASTEWATER CONSULTANTS INC. Permit Fees: Lim+150 = 1550 Date of Payment: '%/`I .102 - Receipt Number: I Waiver Fees• Date of Payment: Receipt Number: ALASKA WATER '& WASTEWATER C O N S U LTAN TS, INC. +"""'"'""""" July 8, 2002 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragraw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Proposed and Well Septic System Design for Lot 6, Block 1, Tower Estates Subdivision To whom it may concern: The proposed 3 bedroom house will be served by a private well and septic system. Two test holes were excavated in the area of the proposed septic system. The septic system will be designed around the 30 foot radii of these test holes. We are proposing that a 1000 gallon septic tank and a five foot wide drainfield be installed. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. It is our opinion that an application rate of 0.6 gallons/day/ftz should be used. 2. TRENCH DESIGN: a. Percolation Rate: 12.9 & 17.7 minutes/inch b. Allowable Application Rate: 0.6 gallons/day/ft c. Number of Bedrooms: 3 d. Design Flow: 450 gallons per day e. Minimum Absorption Area: 750 ftZ f. Total Depth: 2 feet (max.) 1 foot of leveling sand g. Effective Depth: 0.5 feet h. Width: 5 feet i. Minimum Length: 150 feet long total (2 @ 75 feet) j Effective absorption area= 750 ft2 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed upgrade. 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com 4. TOPOGRAPHY: As can be seen on the attached design, the average topography where the proposed drainfield is to be installed is a 40f percent slope running from approximately north to south. A plywood/visqueen barrier is to be installed around the perimeter of the trench to insure that the effluent will be below the organic layer. Once below the organic layer, the effluent should move downward rather rapidly with minimal lateral migration. Therefore, we are proposing to fill below the trench so as to create a slope of less than a 25 percent for a distance of 35 feet downhill from the trench. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your P.E., M.S. NOTE: Attached is a site plan drawing, a design drawing, two soils log, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com �vACANID TOWER ESTATES S/D; LOT 2, BLOCK 2 ALASKA w 01 DEBARR ROAD, SUITE 28' ANCHORAGE. AK 99504' PHONE (907)337-6179. FAX (I. PARED FOR PHONE NUMBER: TERRI WHITE 338-5251 CL DESCRIPTION: TOWER ESTATES SUBDIVISION; LOT 6, BLOCK 1 OF WORK: SITE PLAN iI \\ ACNTANT I I \QAC I li 7 Z.T.G. U=: 1 " = 100' E NUMBER: 1 OF 1 i I I I I I I I I I i I I I I I I I I IGONZALES HOMESTEAD S/D; TRACT 8 I I I I I qAACANTD 3 rA hill" fliffall 0 J y rn ss. - E 795 Psi �cP! d�_e. ... •.041 � / T \ TOWER ESTATES S/D; LOT 2, BLOCK 2 ALASKA w 01 DEBARR ROAD, SUITE 28' ANCHORAGE. AK 99504' PHONE (907)337-6179. FAX (I. PARED FOR PHONE NUMBER: TERRI WHITE 338-5251 CL DESCRIPTION: TOWER ESTATES SUBDIVISION; LOT 6, BLOCK 1 OF WORK: SITE PLAN iI \\ ACNTANT I I \QAC I li 7 Z.T.G. U=: 1 " = 100' E NUMBER: 1 OF 1 i I I I I I I I I I i I I I I I I I I IGONZALES HOMESTEAD S/D; TRACT 8 I I I I I qAACANTD 3 rA hill" fliffall 0 J y rn ss. - E 795 Psi �cP! d�_e. ... •.041 � PROPOSED DRAINFIELD. EXCAVATE TWO— TRENCHES THAT ARE 2' DEEP MAXIMUM BY 5' WIDE BY 150' LONG TOTAL (2 O 75'). ADD 1' OF MOA APPROVED LEVELING SAND THEN 0.5' OF CLEAN, WASHED SEWER DRAINROCK. INSTALL TRENCHES PARALLEL TO SLOPE CONTOURS. F / F (VACANT •1 BE 4DA / OPE *DIMENSIONS FOR MOA PURPOSES ONLY. DO NOT USE R LAYOUT OF SEPTIC SYSTEM. -mnam—.^ra:..,a ALASKA WATER & WASTEWATER w� CONSULTANTS, 044. 5901 OEBARR ROAD. SUITE 213 . ANCHORAGE. AK 99504 - PHONE (907)337-6179 . FAX (907)338-3246 2EPARED FOR PHONE NUMBER: TERRI WHITE (907) 338-5251 :GAL DESCRIPTION: TOWER ESTATES SUBDIVISION; LOT 6, BLOCK 1 'PE OF WORK: PROPOSED SITE PLAN 7 Z.T.G. LE: 1" = 50' E NUMBER: 2 OF 3 WELL TALL FOUNDATION CLEANOUT i f INkTEROW SEPTIC SYSTEM I ALASKA WATER & WASTEWS CONSULTANTS, INC 6901 DEBARR ROAD, SUITE 2B' ANCHORAGE. AN 99504 . PHONE (907)731-6179 . FAX Q PREPARED FOR: PHONE NUMBER: TERRI WHITE 338-5251 LEGAL DESCRIP11ON: TOWER ESTATES SUBDIVISION; LOT 6, BLOCK 1 TYPE OF WORK: PROFILE DRAWING OF SEPTIC TRENCHES 7/8/2002 pP�F .... • • p 0 DRAWN BY' Z.T.G. R SCALE. 5246 N.T.S. ......... . .. ..... .......� PAGE NUMBER: 1 OF 4............ . OQ p �•. f 4. m si O� _ _ QO� s 7953 Q�°moo,. �_ • � • 0 � E°w �� � . • , .,�;� ALASKA WATER & WASTEWATER4 CONSULTANTS, INC, _ * - IJVIL LVV — rLICI+VL/iIIVl7 ILJII �.. LEGAL DESCRIPTION: i S/D: LOT 6, BLOCK 1 e arnec O E 7953 m`4 PERFORMED FOR: TERRI WHITE DATE: 5/1/2002 OQ�m cpQ4 DEPTH Q 4ed' ••. .... \��Av 0 P o (tear) essio'�o ORGANICS EST HOLE #1 �000000' 1 0 17 0IINIIpIL :' • ' 11 12 13 14 15 16 17 18 DEPTH TO GROUNDWATER DATE DRY 5/1/2002 WATER LEVEL READING SOIL CLASSIFICATIONS 5/1/2002 1 5:57 - 6" - 20 2 6:27 GW 4 1/4- 1 3/4- •- 3 6:28 - r N - W ERFORMED IN ACCORDANCE 4 - 30 IIIlillllML 1 3/4" y 7:00 - 6" - II�111!11 6 7:30 30 4 5/16" 1 11/16- M%/% N/N%CL • muniMH M GM - CH sm OH yM 1`,'�4j'���� Sc 17 0IINIIpIL :' • ' 11 12 13 14 15 16 17 18 DEPTH TO GROUNDWATER DATE DRY 5/1/2002 WATER LEVEL READING NET DROP (INCHES) 5/1/2002 1 5:57 - PER Z5 5�n w—oct DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 5/1/2002 1 5:57 - 6" - 20 2 6:27 30 4 1/4- 1 3/4- 3 6:28 - 6" - W ERFORMED IN ACCORDANCE 4 1 6:58 30 1 4 1/4" 1 3/4" 5 7:00 - 6" - 6 7:30 30 4 5/16" 1 11/16- 19 PERCOLATION RATE 17.7 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 3 FT. AND 4 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: E YES ❑ NO SOILS LOGGED BY: JASON WOOD PERCOLATION TEST PERFORMED BY: JASON WOOD COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W ERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: � OZ ALASKA WATER & 'WAST " CONSULTANTS,'INC. -ma E i LEGAL DESCRIPTION -S/D; LOT 6, BLOCK 1 O of A. Hess: —7953 PERFORMED FOR: TERRI WHITE DATE: 5/1/2002 Q4s ticOG Q 40 �pAv (feet)DEPTH - 4 4440���OOoo 1 ORGANICS ITEST HOLE 2 19 0 9 FRACTURED 10 BEDROCK 11 B.O.H. 12 13 14 15 16 171 DEPTH TO GROUNDWATER DATE DRY 5/1/2002 W SOIL CLASSIFICATIONS 5/1/2002 1 6:01 — 6" — ■ 6:11 10 3 3/8" M 3 6:13 — 6" GW 4 • 10 3 1/2°° 2 1 2" 5 6:25 — 6" — MRG L 6:35 10 3 1/2" 2 1/2 7 il�n �n GM 6" iiiCL 8 N 10 3 1/2- 2 1/2" _�NN�I 6:47 — 6" • y 6:57 M 3 5/8" 2 3/8" 11 6:59 Illllllii 6- y 12 7:09 10 3 11/16°° 1 2 5/16°° _ %//%CH SM OH SC 19 0 9 FRACTURED 10 BEDROCK 11 B.O.H. 12 13 14 15 16 171 DEPTH TO GROUNDWATER DATE DRY 5/1/2002 W s ppa 5/1/2002 1 6:01 — ,?FR 3ASo*Woo-0 DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 5/1/2002 1 6:01 — 6" — 2 6:11 10 3 3/8" 2 5/8" 3 6:13 — 6" — 4 6:23 10 3 1/2°° 2 1 2" 5 6:25 — 6" — 6 6:35 10 3 1/2" 2 1/2 7 6:36 — 6" — 8 6:46 10 3 1/2- 2 1/2" 9 6:47 — 6" — 10 6:57 10 3 5/8" 2 3/8" 11 6:59 — 6- 12 7:09 10 3 11/16°° 1 2 5/16°° 19 I I PERCOLATION RATE 12.9 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 2.5 FT. AND 3.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: E YES ❑ NO SOILS LOGGED BY: JASON WOOD PERCOLATION TEST PERFORMED BY: JASON WOOD COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WA P RFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: O Z _