Loading...
HomeMy WebLinkAboutGLENN VIEW ESTATES NORTH BLK 1 LT 16Glen View Estates North Block i Lot 16 #051-821-29 Municipality of Anchorage Page 1 of 3 Development Services Department Onsite Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SWO40065 PID Number: 051-821.29 Name: Wastewater System: New MM&M Contracting, Inc. Address: P.O. Box 670495 Chuciiak, AK 99567 ABSORPTION FIELD phone. NularBedrooms: 5' Wide Trench 688.1236 Four 4 Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION ,8 GPDJFF 6 Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 1 16 Glenn View Estates North 2 Ft. 4 Ft. Township: Range: Section: Fill added above original grade: Gravel Length: 1.5.3 Ft. 75 Ft. Gravel width: Numberof lines: Distance between lines: Well: Municipal Water System 5 Ft. 1 I Ft. Classification (Private, A. B, C): Total Depth: Cased to: Total absorption area: 750 Ftp Pipe Material: ASTM 3034 PVC Ft. Ft. Driller: Date Drilled: Stacie Water Level: Insaller: MM&M Contracting, Inc. Date installed: 1 4120.22104 Ft. Yeld: Pump Set at:Casing eight Above Grouts: TANK GPM Ft. Ft. SEPARATION DISTANCES (D septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift I Holding ubliGPnvate -ffa" Anchorage Tank �apacrty In e ons: 1,250 From Tank Field Station Tank Sewer Line ens: um aro ompertments: well >200' >200' NIA NIA >25' Steel Two (2) >100, >100, NIA N/A LIFT STATION — NONE ON LOT Surface Water Lot Line >6 >10, NIA NIA z: Gal. 150V >5' >10, N/A NIA is ump onlevel aL P.m ;n. Dh wa araarm ac in. Foundation ;n. Pump Make 8 Model Eleatricai Inspections performed by: Curtain Drain None Noted Remarks BENCH MARK Localon am vescriptom: Finished First Floor ume evaion: 100.0 Ft. Engineer's Stamp OL*'•OS qrr .E .• ............. Si♦♦ Inspections performed by: T.L. Kimbrough Dates: 1a` 4121104 f 4 th 2"d 4122104 Department of ealth and Human Services approval MICHAEL E. ANDERSON W ♦♦� Nc CE_4381 sT, Date: ♦♦Okil1pROFEss\o�::•�• Rev0e9wed and approved by: rrn•..• r O � �m W r OT �♦ Cn � A N N A J O D iO 0] U r m ��w a, zbovba < m io w m C � Z D --I m O A O O p G NJ Cmn 0] 0 m�G m F �In D alis elewaliv 0 N � c W D 7 m qg m= vi Zc o 0 L < -t x ® w D (n a /nn V/ I[ N • A 2L= Mom o A� O C Ool o r) �, m� m� N 3PN� mm m 2 O 3 CD 0 y o m r m o ov z 3 77 A N a W O � A a N N � �D 2� Q� i p �e :s •Oi y: -TI io 11•;l e �.•'` ania4 eonidS Amope4S Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SW040065 N UU Q 2' Ir)suL,ll 1,250 Gallon 4.35 PID No. 051-821-29 PROFILE AS -BUILT - Scale: 1" = 10' 4/0 Ibt�D MUNICIPALITY OF ANCHORAGE Development Services Department K OO On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Apr 20, 2004 Expiration Date: Apr 20, 2005 Permit Number: SW040065 Parcel ID: 051-821-29 Legal Description'°�G qe n Viewstates North Block 1'Lot 1,6 y Design Engineer: 0014 Anderson Engineering Site Address: Unknown Owner Name: MM&M Contracting Lot Size: 40822 SQ. FT. Owner Address: P.O. Box 670495 Total Bedrooms: 4 Permit Bedrooms: 4 Chugiak , AK 99567. This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: Date: Zo Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. z Zq Permit Number SW Property owner(s) MMBM Contracting Day phone 688.1238 Mailing address (1) P.O. Box 670495 Chugiak AK 99567 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 16, Block 1, Glenn View Estates North Subdivision Legal description (Section, Township & Range) Lot Size 40,822 Acres/Sq.Ft. Number of Bedrooms _Four (4) THIS APPLICATION IS FOR: pPGG.yi'(y ��i SAFETY Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Waiver Fees: Date of Payment: t z- -, Z.57-03 Date of Payment: Receipt Number: (,20,(4 -el CST Receipt Number: (Rev. 12/00) December 29, 2003 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 16, Block 1, Glenn View Estates North Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 16, Block 1, Glenn View Estates North Subdivision intends to construct a four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is currently served by a community water system. The attached Site Plan and backup documentation identify the location and configuration of the water service and proposed septic system and alternate site. No conflicts exist between the water service and septic system on this lot and those on adjacent properties. Drainage arrows with representative surface slopes are shown on the Site Plan. The drainage pattern will be maintained after development of this lot is complete.' A test hole placed on the lot in the area of the new absorption trench completed by Tobben Spurkland, P.E. indicated silt with sand with a percolation rates of 13 minutes per inch. No groundwater was found in the monitor tube and none was noted during the monitoring period. We are therefore proposing to place a new 1,250 -gallon septic tank along with a 75' long by 5' wide by 4' effective depth absorption trench to collect and treat the sewage generated in the house. The bottom of the trench will be 6' below the surface. A minimum of 3' of cover will be placed atop the trench and 4' atop the new septic tank. The ground surface on the lot slopes at shallow grades from east to west toward Shadowy Spruce Drive. The absorption trench will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service on the lot and on adjacent lots. It will also be constructed a minimum of Lot 16, Block 1, Glenn View Estates North Subdivision December 29, 2003 Page Two 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 49th MICHAEL E. ANDERSON No. CE -4381 Shadowy Spruce Driveair A :W 0 I_C: VI S: : J e �m O N O LL m = V fJ NQL N N6 941C "n Sod ®4- JWO _ 5 ®4- JWO z xQ J .5-O — 11 CO a W a o U COo o (n N _ U) N L z V! W Q NvJ ®F W E COo E W N o m O � U N O N N a rn2� z Z r CO 0 3 N N r EE W'2 Y `o E'i U O 0 6 Z(l U7� J m F yll is -1 b� z O J LOT 16, BLOCK 1, GLENN VIEW ESTATES NORTH SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House 5' Wide Trench System Perc. Rate: 13 Min./Inch 1,250 Gallon Septic Tank Application Rate: .8 GPD/SF 4' Drainfield Rock 4 Bedrooms X 150 GPD/.8 GPD/SFApplication Rate) = 750 SF Absorption Area 750 SF/5 LF (Width)' .5 (Red. Factor = 75 LF Trench Length THEREFORE: Construct a 75' Long x 5' Wide x 4' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 2' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Natural Backfill 1"6.. Geotextile Fabric 6" 4" Perforated PVC (Holes Down) 4'0" 1 1 �— Drainfield Rock 5' I—i TYPICAL 5' WIDE TRENCH SECTION, •.,.. (NO SCALE)• E of o NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. a;,,,,;; as Minimum 4' Separation From Groundwater. Minimum 10' Separation From Water Service Line. A MICHAEL B ANDERSON Minimum 100' Separation From Surface Water or Streams. •�%:;. No. CE4381 Le�>T" l � � � LOCAL t Depth —4 ti -_I a 7- 8- 9- 12-- 13- 14- 15- - 8- 9- 1213- 14- 15- 17- 18- 19- 20- 17- 18- 19- 20- COMMENTS COMMENTS oR6AMI c.S ML sCk_v�akY G; 14-1C. r X HL 1+AR13 ao?roM o P "OLE WAS GROUND WATER Municipality of Anchorage Gross Time OUNTE ENCOUNTERED? Development Services Department Net Drop 1 ILL Building Safety Division ..,.:. ® �1 On -Site Water and Wastewater Program L Depth to Water Aker Monitoring?.� 4700 South Bragaw St. e Dale: P.O. Box 196650 Anchorage AK 99519-6650 www.ci anchorage ak us (907) 343-7904 s; z Soils Log) -Percolation Test t1; yo Performed For: G L– �'- N �I 1Dyli L� �l`� E} S'f�l Date Performed: Legal Description: — Township, Range, Section: Le�>T" l � � � LOCAL t Depth —4 ti -_I a 7- 8- 9- 12-- 13- 14- 15- - 8- 9- 1213- 14- 15- 17- 18- 19- 20- 17- 18- 19- 20- COMMENTS COMMENTS oR6AMI c.S ML sCk_v�akY G; 14-1C. r X HL 1+AR13 ao?roM o P "OLE WAS GROUND WATER Date Gross Time OUNTE ENCOUNTERED? p Net Drop 1 ILL —� S IF YES, AT WHAT DEPTH? L Depth to Water Aker Monitoring?.� D P E Dale: 0 CA D b. 5 t)rr ICP9Ci `46,� 1 ��yrVn'7Y�A til 111., Reading Date Gross Time Net Time Depth to Water Net Drop 1 ILL PRE oft` z t1; yo -5Z) 7��� ,'L liy 12: to ,3o 73A4 a2 'liq =R,: vOLA ON RA,. 1 J (minutesrmc) PERC HOLE DIAMETER 61, TEST RUN BETWEEN _PFT AND PT ( PERFORMED BY: � S CERTIFY THAT THIS TEST) WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: '/ Z!/''aZ Depth (Feet o 're 2- 3- 4- 7• 8- 9- 12- 13- 14- 15- 16- 17- 18- 19- COMMENTS - 9- 12- 1314- 15- 16- 17- 18- 19_ COMMENTS f7 SaKAy x;14 ML �J OC,KQ\tel J 1 I� �lir-o a� S 3CTr"f-nM OF E1bt_E CE :2225 o as oav,.•m.�4:�,; WAS GROUND WATER �— ENCOUNTERED? a s IF YES, AT WHAT DEPTH? L Depth to Water After D P Monitoring? r•/ E e / Date: /p L Municipality of Anchorage A Development Services Department Building Safety Division On -Site Water and Wastewater Program :s T_ 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650; www.ci.anchorace.ak.us (907) 343-7904:= r Soils Log - Percolation Test; Performed For: - 4 Date Performed: Lecal Description: Range, Section: /tt pTownship, Slope Depth (Feet o 're 2- 3- 4- 7• 8- 9- 12- 13- 14- 15- 16- 17- 18- 19- COMMENTS - 9- 12- 1314- 15- 16- 17- 18- 19_ COMMENTS f7 SaKAy x;14 ML �J OC,KQ\tel J 1 I� �lir-o a� S 3CTr"f-nM OF E1bt_E CE :2225 o as oav,.•m.�4:�,; WAS GROUND WATER �— ENCOUNTERED? a s IF YES, AT WHAT DEPTH? L Depth to Water After D P Monitoring? r•/ E e / Date: /p L T_ Reading Dale Gross Time Net Time Depth to Water Net Drop 1 LL t2E OAA , G l fttloz . tz:3o 3Ot✓1t� ��//8 z�/� �t7 t: 1V -va ala ;1a No 7'1b rcnwL,v i IUN nAIt r,-= (mrmtegm.h) PERC HOLE DIAMETER Fj rJ TEST RUN BETWEEN A FT AND �p FT PERFORMED BY: 1–, 151 1 1 1 S CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: yla//rJz ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 16, BLOCK 1, GLENN VIEW ESTATES NORTH SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 75' long X 5' wide X 4' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 2' below the existing ground surface. Total depth of the trench will be 6' below the existing ground surface. The new septic tank and absorption trench must be placed a minimum of 10' from the water service on this and adjacent lots. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,250 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Lot 16, Block 1, Glenn View Estates North Subdivision December 29, 2003 Page 2 of 3 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield area minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. Lot 16, Block 1, Glenn View Estates North Subdivision December29, 2003 Page 3 of 3 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanoutsand insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. I Lyj I =1�� DATE: 4/19/2004 TO: Joe Goodall WITH: MoA/On-Site Water and Wastewater FROM: Mike Anderson SUBJECT: Lot 16, Block 1, Glennview Estates North Subdivision Septic System Permit Application Attached is a revised site plan along with test hole data completed during the subdivision phase of Glennview Estates North. Please review the data along with the original permit application and, if acceptable, issue the permit for construction. Please let me know if you have additional questions. Parcell.D. 051-821-29 Municipality of Anchorage On -Site Water and Wastewater Program (907)343-7904 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION P q� e I JUN 2'` . Expiration Date: 6 w / (o / 7 Complete legal description GLENN VIEW ESTATES NORTH; BLCOK 1, LOT 16 Location (site address) 22445 SHADOWY SPRUCE DRIVE *CHUGIAK, AK 99567 Current Property owners) GLENN & CAROL HART Mailing address Real Estate Agent Day phone 230-3885 22445 SHADOWY SPRUCE DRIVE *CHUGIAK, AK 99567 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF 4. TYPE OF WATER SUPPLY: 0 Individual Well ❑ Individual Water Storage ❑ Community Class _ Well ❑ Public Water System ❑ WaiverNariance request for: NIA Received by: _ COSA to he released Day phone TYPE OF WASTEWATER DISPOSAL: Individual 19 Holding Tank ❑ Community ❑ Public Sewer ❑ requested by the engineer. Date: COSA Fee $ 15`� — Waiver Fee $ _ I / Date of Payment �G Aq [ / 6 Date of Payment Receipt Number 6M5 Receipt Number COSA 9�SafZV3 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below. I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Garness Engineering Group, Ltd. Phone (907) 337-6179 Address 3701 E. Tudor Rd., Suite 101, Anchorage AK. 99507-3246 Engineer's Printed Name Jeffrey A. Garness Date In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the systems on the dates of the evaluation. Separation distances were measured to readity identifiable features. Hidden defects or encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend on a variety of variables including, but not limited to, soil conditions, groundwater levels (that may fluctuate during the year), quality of construction (materials and wcrkmanshic), and the water usage of the family utilizing the systems. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not guarantee future performance of the systems; therefore, GEG makes no warranty (express or implied) regarding the future performance of the well or septic system. GEG makes no representation whether analternativewell or septic system can be installed on the property in the event either of the current systems fail. The content of this report is for the sole benefit of the oerson/party who retained GEG. Reliance upon the information provided in this report by any other person or party, including but not limited to subsequent oroperfy purchasers, is not authorized. In short, GEG disavows any legal duty to anyone other than the person/oarty.who paid for this report tOF t�t i4fr f( J= ON-SITE bedrooms WATER AND bedrooms "� WASTEWATER o1 PROGRAM O,O SQQR, bedrooms, with the following stipulationSF1d� si�jfjSERv 6. DSD SIGNATURE System #1 Approved for By: The System #2 Approved for Disapproved Conditional approval for upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory cher s7 G r to e ria s ��v COSA blue sheet_9-1-12.tl. �d (/(/h, /7 `� If more than 7 septic system is on the lot: COSA Checklist # _of_ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: GLENN VIEW ESTATES NORTH S/D; BLOCK 1. LOT 16 Parcel ID: 051-821-29 A. WELL DATA PUBLIC WATER Well type If A, B, or C provide PWSID# Date completed Sanitary seal (Y/N)_ Total depth ft. Cased to ft. FROM WELL LOG Date of test Static water level ft Well production WATER SAMPLE RE Coliform coli A c: ug./L. 00 ml. Nitrate - mg./L. Date of sample: _ B. SEPTIC/HOLDING TANK DATA Well Log (Y/N) _ Wires properly protected Casing height (abo rc AT IN TION Collected by: Tank Type/Material SEPTIC/STEEL Date installed 4/21—.22/2004 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (YIN) NO High water alarm (Y/N) N/A Date of pumping 6/16/15 Pumper JR'S PUMPING in. C. ABSORPTION FIELD DATA *BELOW EXISTI G GRAD Date installed 4/21--22/2004 Soil rating .p.d. or ft /bdrm) 0_E System type SHALLOW TRENCH Length 75 ft. Width Gravel below pipe 4 ft. Total depth *8.58 ft. Eff. absorption area 750 fe Monitoring tube YES Depression over field NO Date of adequacy test 6/10-11/2015 Results (Pass/Fail) **PASS For 4 bedrooms Fluid depth in absorption field before test ** in. Water added ** gal. New depth ** in. Elapsed Time: ** min. Final fluid depth ** in. Absorption rate >= 600 g,p,d, Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date — **SEE ATTACHED LETTER REGARDING SEPTIC TEST AND REQUEST FOR AN MOA ADVISORY LETTER. D. LIFT STATION Date installed Slze in gallons Manhole/Acoess "Pump on" level at in. "Pump off" level High water alarm level at in. Cycles tested Meets alar $ circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: PUBLIC WATER Septic tank/lift station on lot On adjacent lots Absorption field on Public sewer main Sewer /septic service line On adjacent lots Holding tank manhole/cleanout nrmar xm7wfimem areas Manurelanimal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 101+ Water main 10,+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER78 CERTIFICATION certify that! have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSH guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date �Iz�lis (Rev. 11/05) GARNESS ENGINEERING GROUP, Ltd CIVIL & ENVIRONMENTAL ENGINEERS June 17, 2015 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Rd. P.O. Box 196650, Anchorage, AK 99519-6650 (907)343-7904 Ref: Glenn View Estates North; Block 1, Lot 16 — Septic Adequacy test for the purpose of obtaining a Certificate of Onsite Systems Approval (COSA). To whom it may concern: GEG completed several site visits to test the septic system that served the referenced property. The septic system consists of a 1250 gallon steel tank, and 5 -wide type drainfield/trench. On 6.9.15, the drainfield monitoring tube reflected a liquid depth of 23". A total of 1050 gallons was introduced into the drainfield, causing the liquid depth to rise to 35". A two hour recovery reading on the septic system reflected that the drainfield did not meet the absorption requirements for a 4 -bedroom home. The drainfield was then monitored the next morning, and the liquid level had actually risen, with only two occupants in the home. On 6.10.15, we proceeded to introduce another 1290 gallons of water into the drainfield, which brought the liquid level to 49.5". The cleanout in the drainfield reflected 1.5" of water, above the invert at that time. We then monitored the drainfield 120 minutes later, and the drainfield had absorbed I" of water, and the cleanout still reflected .5" of water above the invert at that time. This equates to an absorption rate of approximately 1,100 gallons per day. The next morning, the drainfield had dropped an additional 1", bringing the liquid level to just .5" below the invert of the distribution pipe. ONL4 In short, we believe that the drainfield is currently capable of absorbing enrgh water to support a 4- bedroom home. It is important to note that GEG introduced 2,340 gallons (ov r the course of 2 -days), and filled the drainfield to over 100% capacity, and that the absorption occurred in the upper portion of the drainfield. It is our recommendation that the Iv�QA issues an advisory notice for this septic cystPm If you have any questions, please contact Jeff Garness or Rob Campbell at (907) 337-6179 .S. 3701 E. Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessengineering.com Municipality of Anchorage. Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel 1.D. 51-821-29 HAA # Expiration Date: 1. GENERAL INFORMATION Complete legal description Lot 16 Block 1 Glenn View. Estates North Subdivision Location (site address or directions) -�AqJ4S Shadowy Spruce Drive Current Property owner(s) MMBM Contracting Day phone 688.1236 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address P.O. Box 670495 Chugiak, AK 99567 Unless otherwise requested, HAA will be held by DSD for pickup. Day phone Day phone 2. NUMBER OF BEDROOMS: Four 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site M Individual Water Storage ❑ Individual Holding tank ❑ Community Class A_ Well ® Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMEniT -U IIVSPEC T IVry 6Y ErvViN7r-ER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522.7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 8/20/2004 MICHAEL E. ANDERSON ? ii 5. DSD SIGNATURE °s j ., No. CE -4381 _ Approved for bedrooms. ®�o®`®0.�" Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By: Ar i t 6 1 � QL_Qc Original Certificate Date: %I�y (Rev. 12100) ivIUM Develops On-sa IT H, is or u proviae rvvaiu f vml wy ll � "1 _ ryires"properCy pro a ed���� tt asing eight a gr un in srS. mak,...'. � � �� �..�f"4f � ,y �"�;3�s•° 4' �ie�" "maer SIC penis c eatrouw;{ an i ig wa er on r�d zreacmenr past a/ mo.) k rtr+ a eypni 3 �`�' a effect systems ; <,� \ a.. , ......._.. ._ \ gHe__y»�- , ®-4a-J'� _ FROM : COUNTRY REALTY PHONE NO. : 9076881238 Rug. 10 2004 10:34AM P2 -s t s;,e . r ^ i __• a cua�ea mrrrvn aze rvWun me psope" tines ana ao r{at overlap or encr6ich on the property lyi igAdjacent thereto that a 4 a1,, no improvements on property Iyingg a�djacent t$¢ri¢eo encroach on the premises in and t[iat there am no 'roadways. a°<.,<+.<° ° 3 u ;A-*" a ' - - question transmission lines or other yisibie easements on said property ° except as indicated hereon. r° - ... Dated at Eagle River, Alaska' ' > ri0 aenSthis {x r"• day of Mo -Y' 2qQ� t7 <°• r ROBERT. C.TOfi?VSON -AM SCALE: Registered Land Surveyo;No. 88Q -LS' d vp Box 77-0456, Eagle Riven Alaska 99577; Phone (907) 694-2543 -