Loading...
HomeMy WebLinkAboutLAKE RIDGE TERRACE BLK 9 LT 1Lake Ridge Terrace Block 9 Lot 1 #051-323-14 Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program, 4700 South Bragaw St. sl P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On-Sitte�V lastewater Di System and/or Well Inspection Report wosal Permit Number. _ SWO30204 1S O4c�1 1 ` PID Number: 051-323-14 Name: JASON MATHIAS Wastewater System: ■ New ❑ Upgrade Address: 11621 FIRNLINE DR * ANCHORAGE, AK 99516 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 240-3982 ¢ O Shallow Trench O Bed Pound ■Other* LEGAL DESCRIPTION Soil Rating: *3.0 Total Depth from original grade: Block: tot: Subdivision: GPD/Sq. rt, 0.5 ABOVE (MIN) R 9 1 LAKE RIDGE TERRACE Depth to pipe bottom from original grade: SEE DWG. Grovel depth beneath pipe: Township: Range: _ Section: FlII added slows original grade: R 0.52 Gravel length:ngth: R _ SEE DWG. R 25 Ft WELL: ■ New ❑ Upgrade Gravel width: 11 Number o1 I(np: Distance between linen: Classification (Private, A,B,C): Tocol Ds p r Cased To: PRIVATE Total absorption area: FL 2 R. Pipe material: 100 60 Ft, Driller. 275 $0. R D 3034/ F-810/SCH 40 PVC Dote grilled:Uc Water Level: M—W DRILLING 3Z2/2004T 9+ FL Installer. A+ HOME SERVICES Doo Install 7714-15/2004 Yield: Pump Set At Casing Height Ab w, Ground: 3 GPM UNKNOWN R 24+ R TANK SEPARATION DISTANCES aseptic ❑Holding ■S.T.E.P. ■+Other To From Septic Tank Absorption Field Lift Station Holding Tank Public/Private Sewer Lines Manufacturer. ANCHORAGE TANK Capaelty In gallons: 1500 Well 100'+ 100'} 100'} _ 25'+ Material' STEEL Number of compartments: 2 Surface Water 100'+ 100'+ loo'+ - - LIFT STATION Lot Line 5't 1D'+ 5'+ — — Size in gallons: Manufacturer. 1500 41 ANCHORAGE TANK ORENCO SYSTEMS Foundation 5'} 1 D'} s'+ — — Pump on Iwai ab Pump level at: Xigh water alarm at: TIMER 21.5" TIMEt Curtain Drain NONE KNOWN Pump Make & Model: Pecbiml Inspermed by#20 OSI 05 HHF )SG t G Remarks: *THIS IS AN ADVANTEX TREATMENT SYSTEM. BENCH MARK THE TANK IS A 3/16" POLY COATED TANK. Location and DeseriDtiom BOTTOM OF SIDING ® POINT B Assumed Elwatbn: 100.00 R ENGINEER'S SEAL o OF• Q gSgO ©� .... by: Inspections : GEG, Ltd. p p Y Dates: 1st 7/14/2004 .x-00 �� 4 ... .............. 2nd 7/15/2004 D 3rd 7/15/2004 4th 7/15/2004 5th 7/15/2004Q �VA f e Garn ss: Q Development ervices Department A proval 53 Reviewed and approved by:f (Rev. 12/01) Q tP.: n" u40�a prof a, �40po`a4� PERMIT SWONUMBER: A S -BUILT DRAWING PARCEL ID NUMBER: SWO3O2O4 � `N��1-7'7(� 051-323-14 T / y NEW I'WELL / z NEW \ \ 4 BEDROOM HOUSE / \ A / \ B FC I / \ I NEW 1500 GALLON STEEL / ADVANTEX SYSTEM NEW DRAINFIELD MND EXISTING CATCH BASIN FOR FRENCH DRAIN {�MH TH#2' MT1 a2 A B C MTFCO 8.04 114.23 s ALTERNATE SITE-/MT3° .�y / I DATE: _ 10/29/2004 r� S4 + � � DRAWN BY: �,�, _., .« n � Www.. .: GARNESS ENGINEERING GROUP, Ltd. A'J.G./C.J.G. .. ' /r Op ;.u�,-wrz - CONSULTANTS 8 GENERAL CONTRACT6118 SCALE: A. H 370I F. TUDOR ROAp, SUITE 101 ' ANCHORAGE, AK 99507 ' PHONE (907)337-61'9'` RAX (90])3383246 1 " = 40' . ................. . PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JASON MATHIAS (907) 240-3982 2 OF 3 ...... "' ""� LEGAL DESCRIPTION: On -P e A. Garness,.CE-7953 LAKE RIDGE TERRACE SUBDIVISION; LOT 1, BLOCK 9 TYPE OF WORK: ..444a^Pa AS -BUILT DRAWING OF NEW WELL AND SEPTIC SYSTEM Opooc�oCo' �4 PERMIT NUMBER: AS—BUILTSW030204-30204 DRAWING' RGWI 4 PARCEL ID NUMBER: 051-323-14 TOP OF MANHOLE FINAL GRADE = TOP OF ADVANTEX POD = 102.55 (AVG). 102.6 = 102.57 (AVG. TOP OF MANHOLE _ 102.38 (AVG.) e r FLOATS TOP OF TANK Ilu �I II 95.87 IIIIIIII V TOP OF TANK = 95.96 SAND INVERT OF PIPE = 96.80 — — T , INVERT OF PIPE 11500 GALLON STEEL = 95.26 ADVANTEX TANK BOTTOM OF. / VAULT °'4,�r",�d, PUMP VAULT ORE PUMP = 94.46 VAULT ) DRAIN FIELD BED TO BE TOPSOILED FINAL GRADE AND SEEDED IN THE PLYWOOD AND MT = 108.20+ INSULATION MT SPRING/SUMMER OF 2005. VISOUEEN BARRIER FILTER FABRIC PLYWOOD AND VISOUEEN BARRIER /— ORIGINAL GRADE TH#'.... / = 103.27-104.88TH#I n / TOP OF SAND 105.38 (AVG BOTTOM OF BED 11' WIDE =103.38 INVERT OF DISTRIBUTION LINE = 105.90 (AVG.) THE DISTRIBUTION LINE IS 1.25 RELATIVE ELEVATION OF INCH SCH. 40 PVC WITH } INCH HOLES GROUNDWATER = 101.38 SPACED 18 INCHES ON CENTER. (15 HOLES PER LATERAL/30 HOLES TOTAL. J RELATIVE ELEVATION OF — BOTTOM OF TESTHOLE = 94.27 "" UAI L: ; ..1y... 11/1/2004 z 3�� DRAWN BY: GARNESS ENGINEERING GROUP, Ltd. A.J.G./C.J.G. -111 pil -1 CONSULTANTS & GENERAL CONTRACTORS .SCALE: 3701 E. TUDOR ROAD SUITE 101 "ANCHORAGE, AN 99507' PHONE (907)337-6179 `FAX (907)338-5246 1 - 40' 'REPAIRED FOR: PHONE NUMBER: PAGE NUMBER: JASON MATHIAS (907) 240-3982 3 OF 3 .EGAL DESCRIPTION: LAKE RIDGE TERRACE SUBDIVISION; LOT 1 BLOCK 9 YPE OF WORK: AS -BUILT DRAWING OF NEW SEPTIC SYSTEM EXCAVATION DEPTH LIMITED TO 1.5 FEET )OTTOM OF BED = 101.77 RELATIVE ELEVATION OF V GROUNDWATER = 99.77 .✓, o�Q6o oppp V.. (i M -W Drilling, Inc. *P.O. Box 110378* Anchorage, AK 99511• ♦907-345-4000 ♦ 907-345-3287 Fox* Job No.: o4 -Ars Project No.: N/A Permit No. SWO30204 * Well owner. _ * Legal Description: Groundwater Well As -Built & Leg , AMEf4MD Construction *Use of Well Domestic 4Hole Depik. 100' *Casing Size. 6" *Cased ro: 60.37' •Material: A 53 Steel 4 Drill Method: Air Potary Perf. Downhole Air ♦Well Completion- Open end X Screen Perorated X Method. Perforations *Sereen/Perforatlon deacrlption: 4 rows of slots: 3/16" x 0--ea—ch, 5 each per row per foot From 36' – 40' +Grout Notes: (1) Sack- NO. g bentonite granules 4 Weft Development: Method: Air surge Notes: Nitrates tested as no-detect-i.e. <O, l ml/I *Static water level (SWL) 9+ (above) (below) top of casing ('!OC). * Well yield test at 3 gallons per minute (GPM)/ ) for I hours with100°/a of drawdown (DD) from static level (SWL). ♦Method: Air lift *Dale of completion: 02 March 2004 Well Log *Pump Install: Depth in feet from top of casing, Details of formations penetrated, size of material, color and hardness. - 0_TO 2.55 Casip&stick—.—wet-'--"----- _.__ ,,--- .--.......__ .:—.,,._......-. 2.5 TO 8 Surface o�anics: wet .,.__...._......_.... --8 TO —18 Siltygravel: dam_.__.._ 18 TO 26 Sit ravel: wet 26 vwTO.. --36 -Si1tY._..g'ave!:. do .._._.— —...._--._...__,,..-- ..............---......---...._._..,. - - ,... _ 36 TO 43 Water bearing graver 5' -- boulder in this zone 43 TO 50 Silty gravel: dry 50 T _ WAYN� E, WESi"i3i•=RG ._-.,.. --- ->t O ...............---.._.. --- ._..._..._—_.. ,. --_ ._......_._._-.. PresMent,_WF-=-thl-Gritlfing;inC----------- ..--- .. TO --...... CeflificsteAlos. r.a. &3.. _...._..._ - ...._.... ........ .. TO -._......--------.._ TO —...... _.....0 --- �,,, ,...—_....- ---._._-...__................—....._._..... ----.......... -...........- ...-... QCT -29-2004 03:09P FROM:A+ HOME SERVICES, IN 907-868-6770 ?0:3383246 October 29, 2004 ED'S ELECTRIC INC. P.O. BOX 210767 ANCHORAGE, AK 99521 A + Home Services 7501 E. 140th Avenue Anchorage, AK 99516 To Whom It May Concern: Subject: Septic system 14200 Handy Loop, Eagle River, AK P:1/1 ANCHORAGE (907)272-4597 Fax: (907) 272-4590 Ed's Electric, Inc. installed electrical on subject project to the code requirements of the National Electrical Code and the Municipality of Anchorage. Thank you, I�,-Lx Dwayne R. Bruns Ed's Electric, Inc. OCT -29-2004 FRI 03:07PM IU:A+ HOME. SERVICES, INC. PAGE:1 p MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Renewal Date Issued: Nov 03, 2004 Expiration Date: Nov 03, 2005 Permit Number: SW040471 Parcel ID: 051-323-14 Legal Description: Lake Ridge Terrace Design Engineer: 0855 Garness Engineering Group, LTD Site Address: 18138 Fish Hatchery Road Owner Name: JASON MATHIAS Lot Size: 21303 SQ. FT. Owner Address: 14200 HAROLD LOOP Total Bedrooms: 4 Permit Bedrooms: 4 EAGLE RIVER, AK 99577 - This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. Mound system must be designed by an engineer and constructed to meet or exceed the following standards: The upper six inches of a mound system must consist of top soil and be vegetated sufficiently to prevent erosion. Received By: c!Vyh} �L ct Date: �U Issued By: Q _ � �l d� ��c >��t Date: 111-- 4m { _ Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www. ci.enchorage. ak. us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 061- 3a3"_(q Permit Number SW Propert. Mailing phone YOf 7 - ` LIo Dode ..Site address /6106 c.715 ' W Zip Code Legal description (Lot, Block & Sub'd.) LDT L �(LZ^Sr4 I L (CLJLY IrX� Legal description (Section, Township & Range) f Lot Size al, 50 6 Acres — Number of Bedrooms '7 THIS APPLICATION IS FOR: v Sewer Only Well Only Sewer and Well ❑ Water Storage Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi Swimming Pool ❑ Water Softening Unit Therapy Pool ❑ 7t 1 a I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: "ice- Waiver Fees: Date of Payment: II /DJ7 /� Date of Payment: Receipt Number: Receipt Number: (Rev. 09/04) MUNICIPALITY OFANCHORAGE f) Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number: SW030204 Legal Description�L ke Tifge'Terrac WL-" Design Engineer: 0041 AK Water & Wastewater Consultan Owner Name: Daniel Amos Owner Address: 4241 B Street Anchorage , AK 99503 - Date Issued: Jun 19, 2003 Expiration Date: Jun 18, 2004 Parcel ID: 051-323-14 Site Address: 18138 Fish Hatchery Road Lot Size: 0 SQ. FT. Total Bedrooms: ,0y Permit Bedrooms: A This permit is for the construction of: Z Disposal Field 0✓ Septic Tank Holding Tank [] Privy Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). (Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. Received By: Issued By: + Date: Date: l9 �1 Municipality of Anchorage 11lly R'4C PLi Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION r� z FORS jA SINGLE FAMILY DWELLING Parcel I.D. t _ )��—JZ � I `T Permit Number Property owner(s) c/o DANIEL AMOS w/ PRUDENTIAL VISTA Day phone 727-4447 Mailing address (1) 4241 B STREET M ANCHORAGE. AK S l� Mai4iag.address (2) �� �( �� ���� tCN- ,` 1 Zip Code 99503 Legal description (Lot, Block & Sub'd.) LOT 1 BLOCK 9P LAKERIDGE TERRACE SUBDIVISION Legal description (Section, Township & Range) N/A Lot Size 7, ( Acres/ q.Ft. Number of Bedrooms 4 THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well E Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. ALASKA WATER & WASTEWATER CONSULTANTS INC. Permit Fees: � 550 Date of Payment: 6.118/ n3 Receipt Number: w. Waiver Date of Payment: Receipt Number: ALASKA WATER & WA CONSULTANTS, INC. June 10, 2003 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 Ref: Proposed Well and Septic System for Lot 1, Block 9; Lake Ridge Terrace Subdivision ADVANTEX" TREATMENT SYSTEM To whom it may concern: 1. GENERAL: The proposed 4 bedroom home will be served by a private well and septic system. Two test holes were excavated on the property by our firm. We are proposing to design the septic system around the 30 foot radius of test hole #1. Due to shallow groundwater and the limited amount of receiving soils we are proposing to use an Advantex treatment system and a bed type drainfield. The well is to be located in the area shown on the site plan and design drawing. 2. SOILS: See the attached log, which shows the soil classifications, groundwater monitoring, and the percolation test results. As can be seen on the attached logs, the groundwater was at 4.8 feet in TH41 and at 4.0 feet in TH#2 on June 6, 2003. On February 17, 2003, groundwater was at 3.5 feet in TH#1 and at 3.0 feet in TH#2. It is our opinion that the February 17`" reading is not representative of the actual groundwater level This reading was performed during a heavy melt - off and a premature thawing during the middle of the winter. During our 17`h site visit, it was noted that the melt -off was running into the open benches of the test holes. We are proposing to use the 4/1/2003 & the 6/6/2003 readings as our high groundwater level. 3. DRAINFIELD APPLICATION RATE: The intent is to install an Advantex Treatment System that will allow the use of a small drainfield in the area around the 30 foot radius of test hole #1. The Advantex system has received class III approval and we are going to use the minimum application rate of 3.0 GPD/FT2. 4. TRENCH DESIGN: a. Percolation Rate: 7 & 8.57 minutes/inch b. Proposed Application Rate: 3.0 gallons/day/ftz 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507 Phone: (907)337-6179 * Fax: (907)338-3246 * website: akwwc.com c. Number of Bedrooms: 4 d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 200 ft2 f. Total Depth: 1.5 feet (maximum — remove all organics) g. M.O.A. Approved Sand Filter Depth: 2 to 3 feet h. Effective Depth: 0.5 feet i. Width: 10 feet j. Minimum Length: 25 feet long k. Effective absorption area: 250 ft Note: The distribution lines are to be 1.25 inch Sch. 40 PVC with'/4 inch holes spaced 18 inches on center (15 holes per lateral / 30 holes total). 5.ORENCO PACKAGE SYSTEM: The STEP tank with the Advantex Treatment System will be manufactured by Anchorage Tank & Welding to meet the latest design criteria established by Orenco Systems, Inc. The point of contact at Anchorage Tank is Lowell McNutt. As with their standard STEP tank, it is equipped with a high water alarm per M.O.A requirements. 6. SURFACE WATER: There is no surface water within 100 feet of the proposed septic system upgrade. 7. TOPOGRAPHY: As can be seen on the attached design, the area around the proposed drainfield is a 5± percent slope running from approximately southeast to northwest. S. CLOSING: - I am open to any suggestions from your department that would be an improvement to the proposed system. I am unaware of any negative impacts that this installation would impose on adjacent wells, or septic systems. If you have any questions, please call us at 337-6179. 1 n P.E., M.S. NOTE: Attached is a site plan drawing, a design drawing, an Advantex detail, a trench detail, two soil logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507 Phone: (907)337-6179 * Fax: (907)338-3246 * website: akwwc.com n / / t / r / 41 LAKE RIDGE TERRACE S/D; LOT 7, BLOCK 10 1 � � � PAREATIC -• %' / LAKE RIDGE TERRACE S LAKE RIDGE TERRACE S/D;li \\ LOT 6, BLOCK 10 / 1 . LOT 1,BLOCK / LAKE RIDGE TERRACE S/D; r / \\> LOT 2, BLOCK 10 t` -- O � PW U• I LAKE RIDGE TERRACE S/D; / LOT 3, BLOCK 10 /' r EXISTING I — ` TEST HOLE / �ka // TH//2 G�PG / —J ALTERNATE SITE _ jJJ , T15N, R2W, SECTION 36, LOT 6, NO ENCROACHMENT CONCERNS //—EXISITNG FRENCH DRAIN NO SURFACE WATER VISIBLE DURING SITE VISITS I / /LAKE RIDGE TERRACE S/D; I A LOT 2, BLOCK 9 I '1 I 1 1 I I 1 �. LAKE RIDGE TERRACE S/D1 / I i/ .LOT 3, BLOCK 9 \\ // SEM Tq IC/) ASEPT REA----------------------------- `\\ \♦ �/ / I 1 4 9Tc� 'D SEPTIC SYSTEM 'GN, PAGE 2 OF 4) T15N, R2W, SECTION 36, LOT 6, V/v, �2 A ,A.SKA WATER & WASTEWATER SCALE. J.L.M CONSULTANTS, INC. 1 " = 100 6901 DEBARR ROAD, SUITE 20' ANCHORAGE, AK 99504 • PHONE (907)337-6179 •FAX (907)338-3246 'REPAIRED FOR PHONE NUMBER: PAGE NUMBER: DANIEL AMOS 727-4447 1 OF 4 _EGAL DESCRIPTION: LAKBRIDGE TERRACE SUBDIVISION; LOT 1, BLOCK 9, IYPE OF WORK: SITE PLAN FOR PROPOSED WELL LOCATION AND SEPTIC SYSTEM IGel/rgM A. Gorvessr ­...... Pro(es%Ont VISIBLE i ,�-- `✓ r fie/ O o1 40, PROPOSED ` WELL INSTALL \ FOUNDATION / CLEANOUT C M / l / BASIN DRAIN PROPOSED 4 BEDROOM FIBERGLASS ADVANTEX TREATMENT SYSTEM (SEE DETAIL, PAGE 3 OF 4). EXISTING TEST Qbe,ro�o,��o R 4H#2 / \/ ALTERNATE SITE PROPOSED DRAINFIELD. EXCAVATE A BED THAT IS 1.5 FEET DEEP MAXIMUM (REMOVE ALL ORGANICS) BY 10 FEET WIDE BY 25 FEET LONG. ADO 2.0 TO 3.0 FEET OF M.O.A. APPROVED SAND FILTER AND THAN 0.5 FEET OF CLEAN, WASHED SEWER DRAINROCK. THE DISTRIBUTION LINES ARE TO BE 1.25 INCH SCH. 40 PVC WITH 1/4 INCH HOLES SPACED 18 INCHES ON CENTER (15 HOLES PER LATERAL/30 HOLES TOTAL). SEE DETAIL DRAWING, PAGE 4 OF 4.- 6/10/2003 . p�.``c: .' ALASKA WATER & WASTEWATER J.L.Mo �: T 7- vi CONSULTANTS, INC. SCALE: 3701 E TUDOR ROAD, SUITE 101 •ANCHORAGE AX 9950]' PHONE (907)337-6179 •FAX (907)338-3246 1- = 40' Q ...... ................ ..... PREPARED FOR: PHONE NUMBERS PAGE NUMBER: DANIEL AMOS 727-4447 2 OF 4 QO p ff . Gorn s,: LEGAL DESCRIPTION: Q �° 7953 iF LAKE RIDGE TERRACE SUBDIVISION; LOT 1, BLOCK 9, TYPE OF WORK:40a°•Pro /ggs100°oer DESIGN OF PROPOSED WELL LOCATION AND SEPTIC SYSTEM ��Opo slo i / . p�.``c: .' ALASKA WATER & WASTEWATER J.L.Mo �: T 7- vi CONSULTANTS, INC. SCALE: 3701 E TUDOR ROAD, SUITE 101 •ANCHORAGE AX 9950]' PHONE (907)337-6179 •FAX (907)338-3246 1- = 40' Q ...... ................ ..... PREPARED FOR: PHONE NUMBERS PAGE NUMBER: DANIEL AMOS 727-4447 2 OF 4 QO p ff . Gorn s,: LEGAL DESCRIPTION: Q �° 7953 iF LAKE RIDGE TERRACE SUBDIVISION; LOT 1, BLOCK 9, TYPE OF WORK:40a°•Pro /ggs100°oer DESIGN OF PROPOSED WELL LOCATION AND SEPTIC SYSTEM ��Opo slo AdvanTex Treatment System AX20 - Mode lb 40x94 Pod 3-4 bedrooms ent Pump Basin Orenco Systems® I.,. 11 3D FM IIFNT 30' can 6901 DEBARR ROAD, SUITE 2B • ANCHORA PREPARED FOR: DANIEL AMOS LEGAL DESCRIPTION: LAKE RIDGE TERRACE TYPE OF WORK: DETAIL DRAWING OF : 6/10/2003 DRAWN BY: WASTEWATER SCALE. J.L.M. ITS, INC. N.T.S. 74 • PHONE (907)337-6179 • FAX (907)330-3246 PHONE NUMBER: —PAGE NUMBER: (907) 727-4447 3 OF 4 O VISION; LOT 1, BLOCK 9, a fEX TREATMENT SYSTEM (AX20 MODE ib) O e A Gor ess. a 9s -7 ,.•� Fwd INSTALL PLYWOOD BOX THE DISTRIBUTION LINES ARE TO BE 1.25 INCH WITH BRACING AROUND SCH, 40 PVC WITH 1/4 INCH DIAMETER HOLES PERIMETER OF BED SPACED 18 INCHES ON CENTER (15 HOLES PER LATERAL / 30 HOLES TOTAL IN ENTIRE SYSTEM). Q -- MT MT O i r w FROM ADVANTEX TANK/PUMP VAULT— I o g6 + .n 4 OMT MT O r ------------------ 25' LONG 4" MONITORING INSTALL PLYWOOD BOX WITH BRACING AROUND PERIMETER OF BED --- N ORIGINAL 1.5 FEET DEEP (REMOVE ALL ( THE DISTRIBUTION LINES ARE TO BE 1.25 INCH S 40 PVC WITH 1/4 INCH DIAMETER HOLES FINAL GRADE. SPACCH.ED 18 INCHES ON CENTER (15 HOLES PER \ MUST HAVE 2+ LATERAL / 30 HOLES TOTAL IN ENTIRE SYSTEM). 1 FEET OF COVER— FABRIC 1.5 FEET DEEP MAXIMUM (REMOVE ALL ORGANICS) �10 FEET WIDE - 4+ FEET TO 6+ FEET TO BEDROCK OR IMPERMEABLE 6/10/2003 4WN BY: WEJ.L.M. � : 4 .7I N.T.S. p.......... -.... ... ,....... PREPARED FOR: HHUNG NUMULK: _ -^--•• DANIEL AMOS 727-4447 4 OF 4 Q eff e A, Orne S 4 ei LEGAL DESCRIPTION: .� m 795 TYPE OF WORK: fess ,O TERRACE SUBDIVISION; LOT 1, BLOCK 9, 4kJp o o°qo�� DETAIL DRAWING OF PROPOSED DRAINFIELD ���0000�" 01 •ANCHORAGE AX• 99507 •PHONE 90 337-8179 •FAX: W 338-3218 • W®SIZE •kw SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: LAKE RIDUE IEKKAL.t Du1, U1y1D1Wrv, wi 1p ol-vv PERFORMED FOR: DANIEL AMOS DATE:-2/14/2003� DEPTH (feet) ORGANICS TEST HOLE #1� i 14 15- 16- 17- 18— PERCOLATION 5161716PERCOLATION RATE 7 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 1.5 FT. AND 2.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: JOSEPH MARCHETTI COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS S PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: I 0 DEPTH TO GROUNDWATER DATE GP/SP W/ 7— t.vu�.t:• r 3 • ;: •;: SOIL CLASSIFICATIONS_ 8 �iq:�srSq• ML/CL 2 235 9 1 1/2" B.O.H. 10 2:35 — 11 — 12 3:05 30 1 3/4" 4 1/4" GP 5 ML ,3— "'"'••• +ar; • GP/SP MIXED 6 GM 30 CL 4 1/4" { . y�i" W/ ML GC OL 499• THROUGHOUT o 0 0 SP CH 5—SM / / ; OH 6 •ia SC 14 15- 16- 17- 18— PERCOLATION 5161716PERCOLATION RATE 7 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 1.5 FT. AND 2.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: JOSEPH MARCHETTI COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS S PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: I 0 DEPTH TO GROUNDWATER DATE GP/SP W/ 7— t.vu�.t:• r POCKETS / 4.5' ;: •;: LENSES OF 8 9i ML/CL 2 235 9 1 1/2" B.O.H. 10 2:35 — 11 — 12 3:05 30 14 15- 16- 17- 18— PERCOLATION 5161716PERCOLATION RATE 7 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 1.5 FT. AND 2.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: JOSEPH MARCHETTI COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS S PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: I 0 DEPTH TO GROUNDWATER DATE 5.5' 2/14/2003 WATER LEVEL READING 2/17/2003 4.5' 4/1/2003 4,6' 6/6/2003 11 I A.a ess: 79 ...`�oL PROPOSED WELL P' I PROPOSED"", 4 BEDROOM HOUSE d \' / EXISTING i PROPOSED TEST HOLE I SEPTIC YSTEM TH$2 � 1i -,ALTERNATE SITE I PLAN THp1 1-100' DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 6/2/2003 1 2:05 — 6" — 2 235 30 1 1/2" 3 2:35 — 6" — 4 3:05 30 1 3/4" 4 1/4" 5 3:05 — 6" — 6 3:35 30 1 3/4" 4 1/4" IJUIL LUU — t'LR�vLm' ivi. LEGAL DESCRIPTION: LAKE -RIDGE TERRACE SUBDIVISION; LOT 1, BLOCK 9, .. PERFORMED FOR: DAN AMOS B.O.H. DATE 2/17/2003 4,0' DEPTH (feet) 4.0' 6/6/2003 TEST HOLE 2 — 13- l ORGANICS 14- PROPOSE�'\� 1 15- 4 BEDROOM d 16- HOUSE � 17- SOIL CLASSIFICATIONS 30 18— 3 5/8" DUSTING TEST HOLE GW ORG TH 2 ' % ,i SYSTEM GP ML 3 '"'°•�• GP/SP MIXED GM CL W/ ML GC OL 4 'El' ..• THROUGHOUT o °o 0MH SW ° SP CH SM OH ..° wi+?,ya SC 6 `h DEPTH 7 9 .,."..°.' GP/SP W/ POCKETS / LENSES OF ML/CL B.O.H. 10- 2/17/2003 4,0' 11 4.0' 6/6/2003 12- 2131415161718 — 13- l 30 14- PROPOSE�'\� 15- 4 BEDROOM d 16- HOUSE � 17- / / 30 18— 3 5/8" DUSTING TEST HOLE DEPTH TO GROUNDWATER DATE 5.0' 2/14/2003 3.0' 2/17/2003 4,0' 4/1/2003 4.0' 6/6/2003 Je arness. 4@n E-7953 .•' �`G Vn f • .........�o;O LLQOed pyo f ession000 Zin READING CLOCK TIME / 1 /� �.\1 \ PROPOSED00 6/2/200 1 2:04 — B. — 2 l 30 2' PROPOSE�'\� 3 4 BEDROOM d 6„ HOUSE � I / / 30 2 3/8" 3 5/8" DUSTING TEST HOLE ��) PROPOSED SEPTIC TH 2 ' % ,i SYSTEM S TESITE RNATE �i � I SITE PIAN /� THµt' 2 1/2" t'-100' DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 6/2/200 1 2:04 — B. — 2 2:34 30 2' 4- 3 2:34 — 6„ — 4 3:04 30 2 3/8" 3 5/8" 5 3:04 — 6" — 6 3:34 30 2 1/2" 3 1/2" PERCOLATION RATE 8.57 (MIN./INCH) PERC. HOLE DIA. 5" (INCHES) 19 TEST RUN BETWEEN 1.5 FT. AND 2.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: JOSEPH MARCHETTI COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THISA PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: lr • rGGa'j„.„,.+1,,,i •`t i Municipality of Anchorage 4 _ `T = ==`� On-Site Water and Wastewater Program T �. , e' ” (907) 343-7904 Lit. f t';.`�" 'C raj - DEC 072U;1 b Certificate of On-Site Systems Approval ,,l Parcel I.D. 051-323-14 Expiration Date: - .01 c , , • ") \6' 1. GENERAL INFORMATION: Complete legal description Lake Ridge Terrace: Block 9, Lot 1 Location (site address) 14200 Harold Loop*Eagle River,AK 99577 Current Property owner(s) John Flemming Day phone Mailing address Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual El Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: a• i— 4.71./ Distance: Received by: X-` t.. We-4,444+ Date: ///2//7 COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 59(.0 Waiver Fee $ Date of Payment MO (I? Date of Payment Receipt Number Qq nLi-C7 Receipt Number COSA# 06c19415704 Waiver# _ 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road,Suite 101-Anchorage,Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: 12/q--41-- 00000\4, In conducting this evaluation,GEG provided an engineering evaluation of the well and/or septic system o OF ��Q in accordance with the guidelines and regulations established by the Municipality of Anchorage and •.• • 0 industry practices. The reported results describe the condition of the system/s on the date/s of the p\;-\.•• gs�On evaluation. Separation distances were measured to readily identifiable features. Hidden defects or j rte: ��'�� encroachments may exist that were not identified during the evaluation. The operational life of all wells * ; 9 T K ' '•7 00 and septic systems depend upon a variety of variables, including but not limited to, soil conditions, 0 groundwater levels (that may fluctuate during the year), quality of construction (materials and / workmanship),and the water usage of the family utilizing the system/s. These conditions can vary,and j are outside the control of GEG. Satisfactory test results do not guarantee future performance of the Q :ff f-y Gar ss. system/s; therefore, GEG makes no warranty(express or implied) regarding the future performance of �p 9�. CE-7 53 •• � the well or septic system. GEG makes no representation whether an alternative well or septic system V� can be installed on the property in the event either of the current systems fail to perform adequately in k4 fP, .• If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Lake Ridge Terrace; Block 9, Lot 1 Parcel ID: 051-323-14 A. WELL DATA Well type Private If A, B, or C provide PWSID# N/A Well Log (Y/N) Yes Date completed 3/2/2004 Sanitary seal (Y/N) Yes Wires properly protected (Y/N) Yes Total depth 100 ft. Cased to 60.37 ft. Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 3/2/2004 11/28/2017 Static water level 9+ ft. 13.9 ft. Well production 0.5 g.p.m. 1.2+ g.p.m. WATER SAMPLE RESULTS: Coliform 14�&colonies/100 ml. Nitrate ND mg./L. Collected by: GEG. Ltd. Arsenic: "� S ug./L. Date of sample: 11/29/2017 B. SEPTIC/HOLDING TANK DATA Tank Type/Material Advantex/S.T.E.P./Steel Date installed 7/14-15/2004 Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) Yes Foundation cleanout(Y/N) YES Depression over tank (Y/N) No High water alarm (Y/N) Yes Date of pumping Pumper AS REQUIRED C. ABSORPTION FIELD DATA *Below Existing Grade_ **Advantex Treatment System Date installed 7/14-15/2004 Soil rating .p.d./ r ft2/bdrm)**3.0 System type Mound Length 25 ft. Width 11 ft. Gravel below pipe 0.52 ft. Total depth *2.8+ ft. Eff. absorption area 275 ft2 Monitoring tube Yes Depression over field No Date of adequacy test 11/28/2017 Results (Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 618 gal. New depth 0 in. Elapsed Time: 0 min. Final fluid depth 0 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N &type) None Known If yes, give date — NORTH WEST SIDE OF BED IS SHY ON SOIL COVER BY APPROXIMATELY 2". NO HISTORY OF FREEZING PER OWNER (SEE ATTACHED EMAIL). *Second compartment of 1500 gallon STEP tank/Orenco pump vault D. LIFT STATION **See attached maintenance report. ***Per GEG measurement Date installed 7/14-15/2004 Size in gallons *500/41 Manhole/Access(Y/N) Yes "Pump on"level at TIMER/** in. "Pump off'level at TIMER/** in. High water alarm level at **/***31 in. Datum Bottom of Tank Cycles tested ** Meets alarm &circuit requirements? Yes E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main 75 + Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank 75'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain None Known Wells on adjacent lots 100'+ F. COMMENTS NO WATER STORAGE TANKS IN THE HOUSE PER REAL ESTATE AGENT (CHARLIE BAGG WITH KRISTAN COLE TEAM) oQ .4 O G. ENGINEER'S CERTIFICATION v-c OF �`��A ,/ .'•*. • .' Do I certify that I have determined through field inspections and 4 T ..�*DO review of Municipal records that the above systems are in g Q conformance with MOA COSA guidelines in effect on this i� Q date. O-----<'J, f A. arras i Engineer's Printed Name JEFFREY A. GARNESS O17 • E-7953 oO� /91/9" x•.121 1./ o�oODate 12 profession o #AECC884 (Rev.11/05) ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT BETWEEN MUNICIPALITY OF ANCHORAGE AND H Flit mg"S- THIS STHIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this G Day of of 20 /1, by and between i ,. i �+ /Z-41 I-164/v1, herein the"OWNER,"and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein,the parties to this Maintenance and Repair Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as A0 .0CX located Lodce, at(legal description). /� Qi� 1 erra. c 6 1 2 2. Definitions. Alteration. Any change to the design or function of an AWWTS that includes the installation or removal of any parts,components or pieces not included in the original construction permit and design. Certificate of On-Site Systems Approval (COSA). An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with Anchorage Municipal Code(hereinafter,"AMC") 15.65.These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. Permit. An On-Site Wastewater Disposal Permit as required by AMC 15.65 to construct and operate an AWWTS. 3. Term. The term of this Maintenance and Repair Agreement shall begin on the date of approval by the Municipality to operate the installed system or issuance of a COSA,and shall continue while the AWWTS is in use or is operational or until the property is sold or title is transferred by the owner and a new COSA is issued to the new owner or transferee of the property. 4. Alterations,Installation and Removal of Additional Equipment. Prior to performing any alterations to an AWWTS, the owner agrees to obtain an On-site Wastewater Disposal Permit from the Municipality in accordance with AMC 15.65. 5. Maintenance and Repairs. A. Throughout the term of this Maintenance and Repair Agreement,the Owner shall maintain their AWWTS in a satisfactory condition capable of producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. The owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the municipality and the manufacturer of the AWWTS for the entire term of the AWWTS. In addition, it shall be the responsibility of the Owner during the term of this Maintenance and Repair Agreement,and any renewals thereof,at the owner's sole expense, to pay for any and all: (1)repair(s), (2)maintenance, (3)adjustment(s),(4) replacement costs,and (5) inspection costs. B. Owner agrees to comply with all applicable ordinance, laws, regulations, rules and orders for the AWWTS. C. Upon request by the Municipality,the owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system. When a record of maintenance is documented and maintained by the system vendor,the owner agrees to allow the Municipality access to this information. D. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60 for improper discharge. E. Owner agrees that only maintenance and repair personnel approved by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. F. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS upon 24 hours written notice. G. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On-Site Systems Approval. H. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction,maintenance and repair of the Owner's AWWTS. 6. Nonwaiver. The failure of either party at any time to enforce a provision of this Maintenance and Repair Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Maintenance and Repair Agreement or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 7. Amendment. A. This Maintenance and Repair Agreement shall only be amended, modified or changed by a writing,executed by authorized representatives of the parties,with the same formality that this Maintenance and Repair Agreement was executed with, and such writing shall be attached to this Maintenance and Repair Agreement as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this agreement, the only authorized representatives of the parties are: a. Owner: b. Municipality: Director,Community Development or designated authority C. Any attempt to amend,modify,or change this contract by either an unauthorized representative or unauthorized means shall be void. 8. Jurisdiction: Choice of Law. Any civil action arising from this Maintenance and Repair Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Maintenance and Repair Agreement. 9. Severability. Any provisions of this Maintenance and Repair Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Maintenance and Repair Agreement. OWNER: By: � "��-� (signature) Date: 7/2-ec /7 /i ni 0 7/ J. Aze 5' / (print name) STATE OF ALASKA ) )ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this , day of/)'e 6 Q r 20( 7, by ( i woo-th/ J 4 e s-Lov- . • OTA: ' UB IC FOR ALASKA ;••NOTARY%; ,� My 'o.. ission expires: $ —/—/ g POMP r It111�O OF pl es.. MUNICIPALITY: By: / (signature) Date: 1 —l7 (print name) Title: / + \ / so4 0.02± I ' COVERED -49 4 , DETML REBAR '-.9•(...47.2. N.T.S. / w/PLASTIC CAP LS10392 N PEA ow.) • �1 .444e S ,�1. (TYp,) UT�1TY RECOVLD 2-1/2' AL-MON NAT. NOT USED FOR y/ i -1 _.2:.::--------: , GAS p ® 4. �•; ) SURVEY /4. RPO6E OF THIS • �. O,� � _'�1S�Hf1l1`''.'� :�: :�:... WELL {SEE DETAIL) y ;DRIVEWAY: : Munic a of Anchorage On-Site Water and Wastewater Program (907) 343-7904 Certificate of On-Site Systems Approval Parcel I.D. 051-323-14-000 Expiration Date: 1. GENERAL INFORMATION Complete legal description Lake Ridge Terrace B9 L1 Locatiop.(site address) 14200 Harold Loop Curre~i Pr~0Perty °~er(s) Michael & Jenna Evans Mailing address Real Esta, te Agent 2. TYPEOF' DWELLINO: Day phone 14200 Harold Lp. Eagle River, AK 99577 Lisa Conner single Family (w/wo ADU) Duplex Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 Day phone 244-2014 4. TYPE OF WATER SUPPLY: Individual Well [] Individual Water Storage [] Community Class ~ Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual [] Holding Tank [] Community [] Public Sewer II Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. Date: COSA Fee $ ,~, Date of Payment Receipt Number Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my ~eal affixed hereto and as of the validation date shown below, I verify that my investigation, based on proeedures outlined in the Certificate of On-Sit~ Systems Approval Guidelines for this application, shows that the on-site water supp~ and/or wastewater disposal system is ~re) safe, functional and adequate for the number Qf bedrooms and type of structure indicated h~ein. I further verify that based on the information obtained from tJ~e Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Alaska Rim Engineering, Inc. Phone 745-0222 Address 9131 E. Frontage Rd. Palmer, AK 99645 Engineer's Printed Name Charles A. Leer Date 12/1/14 6. DSD SIGNATURE ~ System #1 Approved for . System ~2 Approved for __ Disapproved Conditional approval for ~-* bedrooms bedrooms bedrooms, with th~ following stipg/atlons: The e Development Services Division (DSD) issues Certiflcales of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory X Nitrate Advisory Arsenic Advisory Other COSAbluesheeL~ '- .~ c If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system __ Certificate of On-Site Systems Approval Checklist Legal Description: Lake Ridge Terrace B9 L1 A. WELL DATA Well type Private Date completed 3/2/04 Totaldepth 100 f. Date of test Static water level Well production 3 WATER SAMPLE RESULTS: Coliform ND Arsenic ND pamel ID: 051-323-14-000 ifA, B, or C provide PWSID # NA Sanitary seal (Y/N) Y Cased to 60.37 ft. FROM WELL LOG 3/2/04 9+ ft. g.p.m. Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) 37 AT INSPECTION 11/19/14 19.8 ft. 1.7 g.p.m. colonies/100 mL Nitrate ND mg/L ug/L Date of sample: 11/10/14 Collected by: Charles Leet B. SEPTIC/HOLDING TANK DATA · TankType/Material Septic/Steel/S.T.E.P. (Advantex) Tank size 1500 gal. Number of Compartments 2 Foundation cleanout (Y/N) Y Depression over ~ank (Y/N) N Date of pumping Pumper Date installed 7/14&15/2004 Cleanouts (Y/N) Y High water alarm (Y/N) Y C. ABSORPTION FIELD DATA Date installed 7114&15/04 Soil rating (g.p.d./ft~ or ft2/bdrm) 3.0 gpd/ft2 System type Mound Length 25 ..,.,,~,~ Width 11 ft. ' Grovel bel°w pipe 0.52 ft. II "' :-' --7 T°ta' ?~~' "~'~*'*~''-~-bs°rpti°n area 275--,~-...,;. e, ~ 'f~ M°nit°rirlg tube 4-- Depmssi°n °vet field N Dat .e%~f~qu3~l~es~ Resu ts (Pass/Fail) p For 4 bedrooms Flui~d,epth in absorption field b~ore test U inl Water added ~'1Z.3 gal. New depth U in. Elap~'~,'.'.:,L';~,~ Fna fluddept--~0 in. Absorption rate >= 600- gpd Any re~o~.',~ '~st 12 mo.)(y/N & type) No.ne Known If yes, give date N/A D. LIFT STATION Date installed 7/14&15/04 "Pump on~ level at 24. in. Datum Bottom of Tank E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot > 100' Absorption field on lot >100 ' Public sewer main >75' Sewer/septic service line >25' Animal containment areas >100' SEPTIC/HOLDING TANK ON LOT TO: Building foundation >10' Water main >100' VVells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: Property line >10' Water Service line >25' Curtain drain None Known Size in gallons 1,500/41 "Pump off' level at 8 in. Cycles tasted ~' Manhole/AGcess (Y/N) Y High water alarm level at 35 Meets alarm & circuit requirements? Y in. On adjacent lots >100' On adjacent lots >100' Public sewer manhole/cleanout >100 ' Holding tank >75' Manure/animal excrete storage areas >100' Property line >10' Water service line >25' Absorption field >10' Surface water >100' Building foundation >10' Surface water >100' Wells on adjacent lots >100' Watermain 100 Driveway, parking~ehicle storage F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal' records that the above systems are in conformance with MOA COSA guidelines in effect on this date, Eng,nee s P nted Name . COSA brown sheet_10-10-12.doc 09/17/2614 08:07 8686770 APLI~ PAGE 87 II III ! III · I III · ~:lymnT-'-e~'~ field MaW~mm~ Relm~ Annual Inspection Mike Evens 14200 Harold Loop, Eagle River AK 99577 AX-104335 SW040471 RetHe,~ O&M In~m Measure AnchorageTank 907.272-3543 Mike Blekeslee g07.622-26 08/20/2,013 Inelmct/Oleen Ad~ml'ex Rltet Inel~ Cle~n leted ferm ~e 1-866-~84-7404 Mape(~ ~n 0 a. nl ¥ ZZ Z DE] ! o o o ZZ Z ._.9. II ~ o~ Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907) 343-7904 .400; CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel LD, 1. GENERAL INFORMATION Complete legal description Location (site address or direoti Current Property owner(s) Mailing' address Lending agency Mailing address Real Estate Agent HAA# ()!A D5 DV Expiration Date: C" JASON MATHIAS Day phone 344-3587 11621 FIRNLINE DRIVE * ANCHORAGE AK. '995l"6 Day phone Day phone Mailing address Unless otherwise requested, HAA will be hold by DSD for pickup. 2. NUMBER OF BEDROOMS: q 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or Water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certifie(y my seal affixed hereto and as of the validation date shown below, 1 verify that my invest. Vo , based on procedures outlined in the Health Authority Approval Guidelines for this application, SIl hat the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate r the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE. AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Phone 337-6179 Date /1 i4f A C_o rrD j-Tj ot�j A_ – ,-,,A . P l ckj"D -Tv G31= Engineer's Comments: _%__0ps0,L40 [ 5r_�50 200 In conducting this evaluation, GEG, Ltd. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, Ltd. can therefore CC/��� any warranty or future estimate of how long the system will continue ® l� operational requirements of the ADEC or MOA DSD. The content portitfoyr, the sole benefit of the owner listed above. Any reliance upon or h!S report by arty other person or party is not authorized, nor will it confer any leg y h„ssooa�F 5. DSD SIGNATURE 1/ Approved for bedrooms. Disapproved. P.. .tea . ...... r A ..G. ness.: I4m , E-79 3 Conditional approval for A– bedrooms, with 1.) At the time of title transfer, the new maintenance agreement which shall be returned to this office before an unconditional approval is issued; 2) The upper six inches of a mound syNtem Must Fens#et: e€ top soil and be vegetated sufficiently to prevent erosion. Money to be placed in escrow for the amount of 1.5 times the high bid f=m 2 minimilm -` ' Pert- contractors" for placement of 6 inches of top soil and vegetation. Money in escrow shall not be released until this ff t f•:1,—appr-eval. m`_ shall be completed no later than 6/15/2005. Attachments: y HAA Checklist_ Menance Agreements — L�-- Septic System Advisory Supplemental Engineer's REort �i- Well Flow Advisory Other By:4 (1^. Original Certificate Date: If (Rev. 12ro1) �nun�ui Deve(oprn' c.U. wage, i rtiflent a nae PWSID# N/A Well Log (Y/N) YES (y/N) _YES' Wires properly protected (Y/N) L yrs YES 62J...ft: Casing heigfit ("a6'ove ground)'2`44'­ -in. ' e 0 1 mg./L. " Other bactpria0 " coloriie§/100 ml " � _ �10�26�2004 f sample.l0 20 2004 Co)lected by: ` G.E.G ltd., X Date instaIIed 7/14-15/2004 ipartm�nts ? Cleanouts'Y%�f) ` YES air n"""n" amu _ „µ System type BED/MtiUw1Q 11 it GraveC below pipe 0 52 " ft N. �AnnSnrin 9 1500% 1 Size in gallon « YES _. TIMER/ I have determined.through in 10 High water alarm level I at 46/31 in Pump off" level at in. ,. .�. «, $w, , .,.. YES Cycles tested` NNEWMeetsi alarm circf re.gwreri ants.? HAA in effect on this date U Absorption field „yam nate walei r - Ct. ails on adjacent lots 100'+ rn+ AaiF.,,y ",� .a: .a.—o c..xv� ,.«. ..... v fielii'inspections and f� * J I have determined.through in i ,o , , , , , rhiapal records that the above systems are HAA in effect on this date with MOA guidelines .... e fr Garne s. Tinted Name "JEFFREY A. GARNESS E .._. s� .44 dP 10 0 of SS1 �40oOd`� 57 wzl Po Waiver Fee $ nien,L fl l04 Date of Payment giber �� . Receipt Number lb. yry O EXISTING HOUSE ,yy I 263 0 .19 I ro ^h li LOT 1 8� I� I, S li �2 LIFT STATIONS 00, 0 (9) LOT 2 X98 Os 66, T J 0 W N ORDEREDBY� ,. _, EXCLUSION NOTES: It is the owners responsibility to a ermine the existence of on easements, covenants, or resptnctions '✓ v-- e w/CAP 5/B" RO O N M P, T i- P, S which do not appear On the recorded subdivision lat. NOTE: 329"R AL.MON. MONUMENT h M C INC . Under no circumstances should any data hereonbe used for HUB &TACK f9construction .� or for establishing property lines. FENCE- —x— xSURVEY "A, CERTIFICATION: LANTECH has conducted a ovERHANG- physical survey of this property as shown on thiswooD DECKS - drawing and that the improvements situated there CONCRETE -on are within the property lines and no encroach- ASPHALT- t—ments SEPTIC STANDPIPE®OWATER exist other than noted. WELL- AS—BILT O F: LEGAL DESCRIPTION: 100.0 RUCTION SURVEYORS—PLANNERS—ENGINEERS 103 440 WEST BNSON LVD. 9503 (fox) 561-6626 LOT 1, BLOCK 9, ANCHORAGEEALASKA (907) 562-5291 WORK ORDER NUMBER: DATE:SCT NOV. 01, 2004 tE=30' NUMBER' �P-546 LAKE RIDGE TERRACE SUBDIVISION DAWBYcHEKED GRroos�. 04-L-49A 62;/76 GARNESS ENGINEER] CONSULTANTS & GENERAL November 3, 2004 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 4 td. Ref: Waiver Request and Health Authority Approval for Lake Ridge Terrace S/D; Lot 1, Block 9. A permit (SW030204) was issued on 6/19/2003 for a private well and septic system. The well was drilled on 3/2/2004 by M -W Drilling, Inc to depth of 100 feet. Per the well drillers log the casing was perforated from a depth of 36-40 feet. Per M.O.A. regulations the casing is to be solid pipe from 0-40 feet below ground surface. We request that you grant a waiver for the perforations above 40 feet. The well is at a slightly lower elevation than the septic system and the topography runs from east to west. Given the natural topography the effluent would naturally migrate away from the well. As can be seen on the attached well logs, there is approximately 36 feet of silty gravel and clay that will inhibit the migration of the wastewater. Recent water samples were taken from the referenced property and indicated nitrate levels of 0.1 mg/L and coliform bacteria were undetected. Attached are water sample results from several wells in the surrounding area, which indicate nitrate levels to be below 0.742 mg/L. Based upon the aforementioned facts, it appears that there is minimal risk associated with granting this waiver. If you have any questions, please contact us at 337-6179. Thank you for your assistance. VI.S. 3701 E. Tudor Road, Suite 101 * Anchorage, Ak 99507 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: garnessengineering.com C fsox. 1303, Palmer. 11 W Log Of Wayne Bullock Well Date Completed Oct. 15, 1963 •Locatibn; Firelake Pis# Hatchery Road. 0 to 3.ft. Tpp Soil 3 to 8 ft. Clay, Sand and Small Gravel to 20 ft. Grey CYLY806 Small Gravel. (very Soft.) 20 to 34 ft. Grey clay layers of gravel (Prdd. some water 21 to 22 ft) 34 to 49 ft. Grey clay, Angular gravel, large boulders. Drilled open hole from.34ft. to 49 ft. 11 49 to 53 ft. Med. Size washed gravel layers of grey clay . Making Water at 52 ft. RF.Y'4AliitS ., A piece of 5 inch Casing 3 ft. long And Perforated with a cutting .torch and2 ft. of it is exsposed below the drive shoe. This screen has a solid bottom. PRODUCTION: 10 gal. bailer every 50 seconds. Top of Casing to Water 43 ft. 2 inches 1 Iain. ' " " " " " 36 ft. 2 inches equals 101 GPIi I Min " " " " " 30 ft. 0 inches equals 9 GPM 1 Min, " " " ° " 25 ft. 6 inches equals 72 GPM (Based on one lineal ft. of water ina 6" casing equals 11 Gal.) Static Level of Water 9 ft. from Surface. .If more water is needed the casing could be perfoated 21 to22 ft from top of casing, also 25 to 26 ft, and 31 to 32 ft. Also Measuring from top of casing. This may make another 200GPH. Having 600 G.PH. from 52 ft. sufficient water for domestic needs. Would sugEest setting pump app. 5 ft. of bottom of well. 5 Drilled and Logged by Otto Kockritz, Jr. Palmer, Alaska. COMMERCIAL TESTING & ENGINEERING CO. ENVIRONMENTAL LABORATORY SERVICES 5iNCE1 908 REPORT of ANALYSIS 5833 B STREET Chemlab Ref . # :93.4398-1 ANCHORAGE, AK 99518 Client Sample ID :L3 B9 LAKE RIDGE TEM. TEL: (907) 562.2343 Matrix :WATER FAX: (907) 561.6301 Client Name :S & S ENGINEERING WORK Order :70232 Allowable Ordered By :R. SHAFER Report Completed :08/31/93 Method Project Name Collected :08/24/93 @ 14:00 hrs. Project# Received :08/27/93 @ 19:30 hrs. PWSID :UA Technical Director: Released ed By Sample Remarks: Remarks: ROUTINE SAMPLE COLLECTED BY: RAY. QC Allowable Ext. Anal Parameter Results Qual Units Method Limits Date Date Init ----------------------------------------------------------------------------------------------- Nitrate-N 0.10 U mg/L EPA 353.2/300.0 10 08/30 LLH * See Special Instructions Above UA = Unavailable ** See Sample Remarks Above NA = Not Analyzed U = Undetected, Reported value is the practical quantification limit. LT = Less Than D = Secondary dilution. GT = Greater Than %N SGS Member of the SGS Group (Soc!616 G6n6rale de Surveillance) _... _ _ .._... ••....,....•. 1. •,-nr vIn Inure -uciu leoccv Clll ITW lid O(111<,IA ANALYTICA INTERNATIONAL DRINKING WATER ANALYSIS REPORT FOR COLIFORM BACTERIA INC. Garness Engineering Date Received: 10/26/04 Time Received: 16:00 Date Analyzed: 10/27/04 Time Analyzed: 10:00 3701 E. Tudor Rd Date Reported: 10/29/04 Time Reported: 14:00 Anchorage, AK 99507 Phone Number: (907) 337-6179 S = Satisfactory Fax Number: (907) 338-3246 U = Unsatisfactory POS = Positive Test Result Collected by: JUM ND = None Detected Sample Type: Routine TNTC = Too Numerous To Count (>200 Colonies) CG = Confluent Growth Method of Analysis: Membrane Filtration (SM 9222 B) HSM = Heavy Sediment Masking, Results May Not Be Reliable Comments: Sample Sample Total* E. Coli* Other* Date Time Coliform Bacteria 10/26/04 13:40 ND ND NT L6e-RbAm Amber Hammontree, Environmental Analyst 10/29/04 Analytica International, Inc Anchorage, AK TLIT = Sample Age >30 Hours, Too Long In Transit R = Resample Required NT = No Test * # Colonies/100 ml ** # Colonies/ml HPC** Result Lab# Location Comments NT AX6891 Lot 1, Block 9, Lake ridge Satisfactory ANALYTICA GROUP Gamess Engineering Group, Ltd. Attn: John Goerner 3701 E Tudor Road, Suite 101 Anchorage, AK 99507 907-337-6179 Fax: 907-338-3246 Client Sample ID: Client Project: Location: Sample Matrix: COC #: PWS#: Comments: Sample Comment: Lakeridge Terrace Sampson Est Drinking Water 36542 Analytica International, Inc. 5761 Silverado Way, Unit N Anchorage, AK 99518 Phone: 907-258-2155 Fax: 907-258-6634 Report Date: 10/26/2004 Receipt Date: 10/21/2004 Sample Date: 10/21/2004 Sample Time: 8:30:OOAM Collected By: MH Flag Definitions: MRL = Method Reporting Limit MCL = Maximum Contaminant Limit B = Present also in Method Blank H = Exceeds Regulatory Limit M = Matrix Interference J= Estimated Value D = Lost to Dilution ** = RL higher than MCL; target not detected Lab#: A0410274 -02B Analysis Method Prep Prep Analysis Parameter Result Units Flags MRL Method Date Date Analyst Nitrate as N <MRL mg/L 0.10 Page 4 of 5 Test was cc 4500-NO3E 10/25/200410/25/2004 BB