HomeMy WebLinkAboutSUSITNA VIEW ESTATES BLK 3 LT 3usitnn View Estates Block 3 Lot 3 #020-091-32 Municipality of Anchorage Page 1 of 3 Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number:-SW030342• SWnt4tpol PID Number: -054.82248 Name: Merit Homes Wastewater System: New Address: P.O. Box 111982 Anchors a AK 99511 ABSORPTION FIELD Phone: Number or Betlrooms: 770.4999 Four 4 Deep Trench LEGAL DESCRIPTION Soil Rating: Total Depth from originalgrda: Blodc Lot Subdivision: 3 3 •6 GPD/FF Depth to pipe bottom from original grade: 15 Ft. Gnawl depth beneath pipe: Susitna View Estates 6 F,. 9 Township: Range: Section: Fill added above original grade: FL Gravel Length: .� Ft. 56 Ft. Well: New Gravel width: 3 Number of lines: Distance between : lines Classification (Private, A. B, C): Total Depth: Cased to: Private FL Total 'absorption 1 Ft. -' ipe Materiel: 227 Ft. 52 Ft, 1,008 Ft' ASTM 3034 PVC Driller: Alpine Drillin Date Drilled: 8/1012004 Static Water Laval: 50 FL Installer: Red Dog Masonry DaWnstalled: 8124-10/1512004 Yield: 5 Pump Set at: Casing eight Above Gm w TANK GPM Ft. 2 Ft SEPARATION DISTANCES ® septic ElHolding ❑ S.T.E.P. El Other To Septic Absorption Lift Holding ublic/Priwte " ° on Fran Tank Field Station Tank Sewer Line Anchorage Tank 1,250 wall >100' >100' N/A N/A >25'a: Steel u ompartm Two (2) saRaceweter NIA N/A LIFT STATION - NONE ON LOT Let lane N/A N/A urer: lNoneNoted cal Foundation N/A N/A ump on eve umP eveHigh wa er Navin : in. in. in. Curtain Drain Pump Make B Madel Electrical Inspections perfomled by: Remarks: BENCH MARK bee Lot Line Waiver. Locationa esm on: Garage Slab sum v ion: 100.0 FL Engineer's Stamp �.•�� OF q<rgr Inspections rformed b MEA P Pe Y Dates: 1 8125104,8126104 ; 49th '• • t.. . 2nd 10113104.10115104 i............................. Department of Health and Human Services approval ♦�' MICHAEL E ANDERSON ♦♦ �'• A Reviewed and approved b : / \,• . ' 0. Date: JOIN ♦♦�fT•'�• NO. CE-4381 •�_ • F '' Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SWG40061 PID No. 020-091-32 ILL < FK o � N ¢ 30' N N O p o W O LL Z SUSITNA VIEW ESTATES LOT 3, BLOCK 3 39,408 S.F. S 83'22'36"E. 198.79' 10' U71L. ESM7. T B C .2 31 7.7 39.I.1 21.1 .4 22.3 .4 54.7 C4 Four Bedroom Home �' v E C'r14��0 <e?33E z.o7. �i 49th bV `•�� �............ .. ... V�� ANDERSON � .�.♦.SfF. No. CE -4381 .a .,,Is.: PLAN AS -BUILT SCALE 1' = 40' ARIES COURT w Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SW040061 N y UU N UU 1.250 Septic 75,0 —Page 3 of 3 PID No. 020-091-32 PROFILE AS -BUILT - Scale: 1" = 10' Sep 27 04 08:10a p.1 -,� Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Rick Mystrom httpl/v .ci,anchorage,ak.us Mayor Permit Number: #SW 040061 Date of Issue: 4-19-04 Parcel Identification Number: 020-091-32 Date Started: 8-10-04 Date Completed: 8-10-04 Is well located at approved permit location? ® Yes ❑ No Legal Description: L 3 Ot.K 3 Susitna View Estates Property Owner Name & Address: Merit Homes PO Box 111982 Annhnranp dlaclrn oOF-i4 FF Borehole Data: Soil Type, Thickness & Water Strata stick-up Depth (ft) From To 0 2 Method of Drilling ® air rotary ❑ cable tool Casing type: steel WaI1 Thickness:. 250 inches gravelly silt 2 49 Diameter: 6 inches Depth: 52 feet bedrock 49 227 Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 50 feet Pumping level: 227 feet after 2 hours pumping 5 gpm Recovery Rate: 5 gpm Method of Testing: air lift Well Intake Opening Type: ❑ Open End ® Open Hole ❑Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: bentonite 4 8 Volume: 1 Depth: Start 0 feet Stopped 20 feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: chlorine tablets Comments: Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property Municipality of Anchorage • Development Services Department Building Safety Division r wj' On -Site Water and Wastewater Program ` 4700 South Bragaw St. S A F E T Y P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Mike Anderson Legal description: Susitina View Estates Block 3 Lot 3 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. _ ❑ Additional soils information needed. _ ❑ Water monitoring results inadequate. _ ® Discrepancy in information submitted. Less than 50 feet from drainfield to a 25% slope ❑ Topographic information missing or inadequate. _ ® Incomplete; missing Need soil test and design for alternite site ® Incomplete; missing _ ❑ Additional adequacy test information needed. _ ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. _ ❑ Locations of all soils, percolation and water monitoring tests not shown. _ ❑ Proposed system too deep for soils information submitted. _ ❑ Well log required. _ ❑ Omission in narrative. _ ❑ Insufficient fill over tank or field._ ® Other. Repair cleanouts and monitor tubes Name of reviewer: Jeff Date: 10/5/2004 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number: SW040061 Legal Description:!$usitn3`vi6VE_sT'a")es PoL- 3 L3 Design Engineer: 0014 Anderson Engineering Owner Name: Merit Homes Owner Address: p.o. box 111982 anchorage , A 99511 - Date Issued: Apr 19, 2004 Expiration Date: Apr 19, 2005 Parcel ID: 020-091-32 Site Address: p.o. box 111982 Lot Size: 39408 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of. ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. g,ZS'�(_ h^; ke ^ SON C_4-a&Fp /Ar rr OeC191t CAAAfIC % R"Cr( W'c-� 6R_ Slo 4eET LoNS ray y Poor ):�,egP-(4 Received By: Date: 4- �° , Q Issued By: /I Date: / /9 Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ek.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 02C _ 6o// - 3 -2Permit Number SW Property owner(s) Merit Homes Day phone 770.4999 Mailing address (1) P.O. Box 111982 Anchorage AK 99511 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 3, Block 3, Susitna View Estates Subdivision Legal description (Section, Township & Range) Lot Size 39,408 SF Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms Four (4) Sewer Only ❑ Well Only ❑ Sewer and Well ® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Waiver Fees: Date of Payment: q- /`f— O Receipt Number:®�la jl (Rev. 12100) Date of Payment: Receipt Number: April 13, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 3, Block 3, Susitna View Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 3, Block 3, Susitna View Estates Subdivision intends to construct a four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to serve the new home. The attached Site Plan and backup documentation identify the location and configuration of the well location, proposed septic system and alternate site. Existing spot elevations and the current drainage pattern are identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. The surface slope in the area of the absorption trench exceeds 25% in some areas. Some grading may be required to provide slopes less than 25% for a minimum of 50' past the trench. Test holes placed on the lot in the area of the new absorption trench and alternate site indicated silty gravel with some cobbles to 12" in diameter. The accepting soils were tested and found to have percolation rates of 19 minutes per inch. No groundwater was found during excavation and none was noted during the monitoring period. We are therefore proposing to place a new 1,250 -gallon septic tank along with a 63' long by 3' wide by 8' effective depth absorption trench to collect and treat the sewage generated in the house. The bottom of the trench will be 14' below the surface. The distribution pipe will be 6' below the surface to allow the 25% slope from 2' above the distribution pipe to daylight at least 50' from the trench. Some grading may also be required to provide additional slope flattening. A minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at grades sometimes greater than 25% from east to west as shown on the Site Plan. The absorption trench will be constructed parallel Lot 3, Block 3, Susitna View April 13, 2004 Page Two with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from the well proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, (f av' , Michael E. Anderson, P.E. Attachments 7 6 10 Uil Esml m ^'"� ay. 10JUI11 Esq s 6 rr o g o � 80.00 O 0 2 8 4• 8 rs�so ,+J P 2 0 L WE S89 156'39 -E 147,7$ 230.000.00 0 � o M ° s 9 3 1 �/ 20.E g Ns a O P� �� 59 s4j"w 'aFwni LL e s >y V` Rzo y 10 sao oq•42•E 233.45 �o f.k � a y <� m P � AREA PLAN SCALE V = 100' ' 49 W ik :1*♦ ... ....... ...... .. .. .::. ..� ...........................................10 T MICHAEL E. ANDERSON Fula No. CE4391 Z? • ESSX SUSITNA VIEW ESTATES LOT 3, BLOCK 3 39,408 S.F. 100' RELATIVE ELEVATION FROM ASSUMED DATUM (lYP) 5/8" REBAR (TYP PER PLAT) S 83'22.36'E 198.79' 1 0 10 UTIL. ESMT. Surface Water has been noted — — — in this area. Maintain 100' Separation —_ --_-- Between Open Water and Septic Tank and Absorption Trench. Ld a_ � o O N g 30' ^ V r O n O c 0 b W o L� z Flatten Slopes to Less Than to 50' Downhill From Absorption c and Alternate Site. <25% _257. 1, 0 Gallon ® tic Tonk THz Four Bedroom <25% 6' 27' Home Alternate Propo d Site `25% Well TH7 83' Lon x 3' Wide x 8-- Eff ctive Depth Absorptio Trench `25% a<25% 150' 108' 00 y0• ARIES COURT �� �� ....HC 15D• A. ,..... •• �E 49th SITE PLAN ,,....r.. E. ER � '. MICHAEL E. ANDER', �0 r ' No. CE -4381 SCALE 1 " = 40' '•• ............... LOT 3, BLOCK 3, SUSITNA VIEW ESTATES SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House Deep Trench System Perc. Rate: 19 Min./Inch 1,250 Gallon Septic Tank Application Rate: .6 GPD/SF 8' DrainfieldRock 4 Bedrooms X 150 GPD/.6 GPD/SF (Application Rate) = 1,000 SF Absorption Area 1,000 SF/16 SF/LF = 62.5 LF Trench Length THEREFORE: Construct a 63' Long x 3' Wide x 8' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 6' Below Original Ground Surface. Total Depth to be 14' Below Existing Ground. Maintain 100' Separation From Well on Lot. Provide 3' of Cover Over Trench and 4' Over Septic Tank or Provide 2" Insulation and 2' of Cover. Maintain 100' Separation Between Open Surface Water and Septic Tank and Absorption Trench. Natural Backfill 5'6" Geotextile Fabric 6„ } 4" Perforated }I PVC (Holes Down) 8'0" I I Z> ---I— Drainfield Rock 43 Ift ECTION NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. 0' Minimum 100' Separation From Surface Water or Streams. 1 Minimum 10' Separation From Water Service Line. 01 Municipality of Anchorage Development Services Department 4700 South Bragaw Street Anchorage, AK 99519-6650 SOILS LOG - PERCOLATION TEST PERFORMED FOR:_ LEGAL DES ION: DEPTH (FEET) l7 1 2 3 4 5 ' `1L-1 6 - 7 9 Merit_Homes .2 F -SIS SLOPE WCHAEL Q. ANDERSON ;; �g0 CE -4381 •��� . �� 'oto .......••� DATE PERFORMED: IV 1 ion: PLAN 10 WAS GROUND WATER ENCOUNTERED? 11 S IF YES, AT WHAT ax/ L DEPTH? /: ` O i2 E 13 Depth to Water Aft" None pate: 3 1 04 14 15 16 17 18 19 f 20 Duff PERCOLATION RATE 1P (minutevinch) PERC HOLE DIAMETER 7 - TEST RUN BETWEEN 5'0 FT AND (--0 FT COMMENTS MI GhIITY��i �'RIiSOAKEI'i XmiotQ 'I'a •(%1i PERFORMED 6Y:. 7 1 AA- 1 CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE -0 4918 .r ®.... . . r • Municipality of Anchorage °� ; '" tr MtCHAEI. E: ANDER50r8 � r 0 Development Services Department CE -4381 °'et 4700 South Bragaw Street Anchorage, AK 99519-6650 t °s 4v SOILS LOG - PERCOLATION TEST R�4� '*;A.... I `�r4w, PERFORMED FOR: Merit Homes DATE PERFORMED:_- 0005 LEGAL DESC ON: l *T7%!� '� , S U 5'1 T1':�C Township, Range, Section: 'DEPTH i IPY '� rl- SLOPE, SITE PLAN (FEET) i 2- 34567 3- 4- 5- 6- 7 8. �1 10 11 12 13 14 15 16 17 18 19 WAS GROUND WAT ", d ENCOUNTERED? Ips IF YES, AT WHAT \/ DEPTH? �\ Depth to water�(� M.6h riq? pNone Ram 3/11/04 20 ''® PERCOLATION RATE (minuteVMCII) PERC HOLE DIAMETER AA,,�� It,�TESTRUNBETWEEN gay' FTAND `%� FT COMMENTS a�jr 'y A7 rfz h -F t7 IrKI 0r;z, 't'b PERFORMED BY:. A I-, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE a ................ 4�t 7-T-, y. ............ ............ W --77 Lot _.._.. Lot 3, 63, Susitna View Estates y � F i ,._ f.__ .... 4 i. nz i _ ..... 71 7 i t 1 1 _ Iva, 4- Too s F i T� N20 W " t F r SECTION Br y _u -71 F _... k � .. L _ W .1 � � � ,_.mom �' F 'l,*w ..,_.-»i.-�$ a - ,• { 4 F Y ;--,- . _171 { ZZWn . . . . . . . .- ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 3, BLOCK 3, SUSITNA VIEW ESTATES SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 63' long X 3' wide X 8' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 6' below the existing ground surface. Total depth of the trench will be 14' below the existing ground surface. The new absorption trench must be placed a minimum of 100' from the well on this and adjacent lots. A minimum of 100' must separate the surface water on the lot and the septic tank and absorption trench. The trench must be a minimum of 10' from the lot line. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,250 -gallon septic tank must be procured from an approved source and installed at the location shown. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Lot 3, Block 3, Susitna View Subdivision April 13, 2004 Page 2 of 3 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. Lot 3, Block 3, Susitna View Subdivision April 13, 2004 Page 3 of 3 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam Hl or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. MEMORANDUM DATE: October 18, 2004 TO: Jeff Poet FROM: Mike Anderson, P.E. rv' Ea— SUBJECT: Lot 3, Block 3, Susitna View Estates Subdivision Certificate of Health Authority Approval The absorption trench for Lot 3, Block 3, Susitna View Estates Subdivision was lowered approximately 6'. The down hills slope from the trench was simultaneously flattened to provide a slope of 25% from 2.5' above the distribution pipe invert to a point in the slope 35' away. The attached documentation verifies the new construction of the trench and the flattening of the slope. We have also included a new test hole log verifying the lack of groundwater and bedrock below the deepened slope. The Health Authority Approval Checklist and the Inspection Report have also been revised to include the dates of construction and cover over the new trench. The cleanouts and monitor tubes have been repaired and are now vertical in alignment. In addition, a design for the alternate septic system site is also included for your review. We are confident we have met all the requirements for issuance of a Certificate of Health Authority Approval. Please let me know if you have additional questions MUNICIPALITY OF ANCHORAGE -DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTH (feet) 1- 2- 3- 4- 5- 6- 7- 8- 9- 11 15 16 17 18 19 4L SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION; LOT 3, BLOCK 3, SUSITNA VIEW ESTATES PERFORMED FOR: MERIT HOMES DATE: 10/12/2004 PROJECT No - PARCEL ID# 020-091-32 TECHNICIAN: MEA TEST HOLE #� SI I L FLAN SEE SITE PLAN SILTY GRAVEL WITH SOME SAND MEDIUM COMPACTION GM BOH - 26' COMMENTS: No WAS GROUND WATER ENCOUNTERED NO IF YES Q WHAT D DEPTH OF WATER AFTER MONITORING: DATE OF MONITO AEL E. ANDERSON No. cE-4381 EPTfI? NONE 25% - 5.�=--"-'�_ RING: 10/2N04 GROSS TIME NET TIME DEPTH of NET DATE READING DROP (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 10/12/04 1 1:15 8.5" 2 1:45 30 6.75' 1.75" 3 1:46 8.25" 4 2:16 30 6.63" 1.62" 5 2:17 8.63" 6 2:47 30 7.06" 1.57" PERCOLATION RATE: 19 (MWANCH) PERC. HOLE DIA. E (INCHES) TEST RUN BETWEEN: 10 FT. and_i LFT. TEST TO TEST. SAME SOIL MATERIAL AS FOUND IN TEST HOLE NOS. I AND 2. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 10/26/04 PERCOLATION RATE: 19 (MWANCH) PERC. HOLE DIA. E (INCHES) TEST RUN BETWEEN: 10 FT. and_i LFT. TEST TO TEST. SAME SOIL MATERIAL AS FOUND IN TEST HOLE NOS. I AND 2. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 10/26/04 o o m 01 a NM o 0� 0 I N W o LO _ o co 0 Ln 06 U; c6 co (D Lf) 0 U 0 O 0 0 m 00 Q L r U C N L 0 0 C W S C O Z w O z W K 30' 0 0 0 w L, AEL E. ANDER: No, CE -4301 SUSITNA VIEW ESTATES LOT 3, BLOCK 3 39,408 S.F. - ----- S 83'22'36" E 198.791 10'—UTIL ESMT. .� Four Bedroom Home �N3 Mpnt�ex Troe{ 5Ystem Zp 4cn99 x 3W�tle AbeorP4°r^ TrencleP�� ALTERNATE SITE PLAN SCALE 1' = 40' ARIES COURT LOT 3,BLOCK 3, SUSITNA VIEW ESTATES SUBDIVISION ALTERNATE SITE DESIGN DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home Advantex Treatment System Perc. Rate: 19 Min./Inch Four Bedroom Advantex System Application Rate: 2 GPD/SF Deep Trench with 10' Drainfield Rock 4 Bedrooms' 150 GPD/Bedroom = 600 SF Absorption Area 600 SF/2 GPD/SF/20 SF/LF = 15 LF Trench Length THEREFORE: Construct a 20' Long x 3' Wide x 10' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 13' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over Septic Tank. Natural Backfill 2'6" Fabric 6 1.25" Perforated PVC (Holes Down) 10'0" I I r Drainfield Rock 3' TYPICAL DEEP TRENCH SECTION ••••.� �J � (NO SCALE) • "L .... OF.......... �� NOTE: Grade Area Over Trench to Drain Away. : ? `°•;,> Minimum 6' Separation From Bedrock. 49th .............. ... ...:... Minimum 4' Separation From Groundwater. i Minimum 100' Separation From Wells in the Area. 0 `• ;�............... LE. "�"""'"''' MICHAEL E.A...... N Minimum 100' Separation From Surface Water or Streams. y/�Ap NO. CE4381 ••'r^ • • r Municipality of Anchorage On-Site Water and Wastewater Program z`' (907) 343-7904 Certificate of On-Site Systems Approval tirK 08 2O,g Parcel I.D. 020-091-32 Expiration Date: r 2-- 1 ti 6 9 9n 1. GENERAL INFORMATION: Complete legal description SUSITNA VIEW ESTATES; BLOCK 3, LOT 3 Location (site address) 17000 Aries Court*Anchorage 99516 Current Property owner(s) Leslie Beck & Ronald Moore Day phone 907-360-0715 Mailing address Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) n Duplex n Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage L.j Holding Tank Community Class Well ❑ Community Public Water System LJ Public Sewer WaiverNariance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5"Sb Waiver Fee $ Date of Payment 4111 lq Date of Payment Receipt Number D00$9CI Receipt Number COSA# bSC 19 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101-Anchorage,Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: 1 �Q In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system QF in accordance with the guidelines and regulations established by the Municipality of Anchorage and industry practices. The reported results describe the condition of the system/s on the date/s of the ' . • sO evaluation. Separation distances were measured to readily identifiable features. Hidden defects or : encroachments may exist that were not identified during the evaluation. The operational life of all wells p 41 • TH �/ • .7 00 and septic systems depend upon a variety of variables, including but not limited to, soil conditions, g • • •• groundwater levels (that may fluctuate during the year), quality of construction (materials and 4 workmanship),and the water usage of the family utilizing the system/s. These conditions can vary,and / ... are outside the control of GEG. Satisfactory test results do not guarantee future performance of the ! J 'r: F •. cm-:s: system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of 1n r CE 79 3 , � the well or septic system. GEG makes no representation whether an alternative well or septic system UO's r' ��/I •�c�0 Q�r 6 �T' Ao can be installed on the property in the event either of the current systems fail to perform adequately in Q iZ. '' .. C�o the future. The content of this report is for the sole benefit of the person/party that retained GEG to �\ 0'Pro essjOco\ perform the evaluation. Reliance upon the information provided in this report by any other person or ��OOO000�� party (including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever. #AECC884 6. DSD SIGNATURE System #1 Approved for bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, with the following stipulations: By.' L_d 2 Original Certificate Date: 1-1---/ The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: • COSA Checklist Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 10-10-12.doc COSA Checklist Legal Description: SUSITNA VIEW ESTATES; BLOCK 3, LOT 3 Parcel ID: 020-091-32 If more than 1 septic system on lot: COSA Checklist# 1 of 1 Structure served by this system 1 A. WELL DATA ❑■ Well log is filed with Onsite (or attached) Well production at time of test 2.1+ gpm Date drilled 8110/04 Water storage tank volume N/A gallons Total depth 227 ft Well disinfected for coliform test? ❑ Yes 0 No Cased to 52 ft Coliform bacteria is Negative El Sanitary seal is functioning correctly Nitrate A) 1) mg/L ❑ Nitrate less than MRL (ND) Wires are properly protected Arsenic Cr) ug/L ❑Arsenic less than MRL(ND) Casing height(above ground) 18+ in. Collected by GEG, Ltd. Date of flow test for COSA 3/18/19 Date of Sample 3/20/19 Static water level at beginning of test 56.5 ft Comments B. TANK DATA C. LIFT STATION Age of tank(s) 14.5 years ❑ Required maintenance completed Tank type/material 5E°"`6 EE Age of lift station - years • Standpipes/foundation cleanoutper record drawing Lift station material - Date of pumping �/ 1 2 f i 0. 1+ i-� C-- Comments: N/A D. ABSORPTION FIELD DATA Which system tested (date installed) 10/15104 Adequacy test date 3/18/19 ❑� ALL standpipes present per record drawing Results ❑✓ Pass For 4 bedrooms Total measured depth from grade 17.1+ft(max) Fluid depth prior to test 88 in Measured depth to pipe invert from grade 8.5+ ft(min) Water added 673 gal ❑ N/A—pressurized field New depth 98 in ❑ Monitor tubes go to bottom of drainfield. If not, state Elapsed time 120 min depth into effective * ❑� Code-required soil cover over field Final fluid depth 93 in Absorption rate 600+ gpd [' System presoaked NONE (Required if vacant for greater than 30 days prior to Any rejuvenation treatment(past 12 months) date of test) N/A If yes, enter date N/A Gallons introduced gallons Comments/Deficiencies:'NORTH MT EXTENDS 8.5'BELOW INVERT&SOUTH MT EXTENDS 8.6'BELOW INVERT • COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot> 100' Community Sewer Manhole/Cleanout > 100' ❑✓ Yes if No ft E Yes if No ft Neighboring Tank > 100' QYes if No ft Private Sewer/Septic Line >25' E Yes if No ft Absorption Field on Lot> 100' EYes if No ft Holding Tank> 100' ✓❑Yes if No ft Neighboring Absorption Fields > 100' Animal Containment> 50' ✓❑Yes if No ft ❑✓ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' 0 Yes if No ft ✓❑Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water> 100' ❑✓ Yes if No ft Property Line > 5' 2 Yes if No ft Driveway/Parking > 0' ['Yes if No, comment Absorption Field > 5' ❑✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' ❑✓ Yes if No ft Private Wells > 100' 2 Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft Community Wells >200' 2 Yes if No ft From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ['Yes if No ft Driveway/Parking > 0' E Yes if No, comment Property Line > 10' ['Yes if No *2 ft Wells on Adjacent Lots: Water Main > 10' Q✓ Yes if No ft Private Wells> 100' 2 Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft Community Wells>200' ['Yes if No ft Surface Water> 100' ❑✓ Yes if No ft F. ENGINEER'S COMMENTS *WR#040076 QQo-.0000,,i\ G. ENGINEER'S CERTIFICATION �F 4�� Qo,, �, s��o I certify that I have determined through field inspections and review Q Q of Municipal records that the above systems are in conformance with �i�;. 4'9 H 1\ •.7 00O MOA COSA guidelines in effect on this date. VA •Je eyI. Garness , 0OC 7951 •c5�Qqef4P40Q 44e. COSA Checklist yellow sheet QO ro f e s siO�oa #AECC884 �0000 A 70-287 SUSITNA VIEW ESTATES LOT 3, B LO O K 3 39,408 S.F. S 83°22'36"E 198.79' - - - - - ._ - - - _ - 10' UTIL. ESMT. — I W ;I- Io va—i 30' PO 0 0 o O 0 W �0 z o z 6 I i�)t�ry�e. • O �? { o/• o'�; o. °_ "0o WELL 1I �O� %i �G �o. 0 k+ r' JPO SEPTIC SYSTEM X10 cl • ,,eo. !�r� O O O6 00- • S ik Q(1,.5..‘ -t,',8 v:M S 72°02 33,EE" 66. X52. o 0 • o 49.7• I� 0 ARIES COURT FINAL STRUCTURE AS-BUILT AS -BUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO �4...OF 1. S GASTALDI LAND SURVEYING ENCROACHMENTS EXIST EXCEPT AS INDICATED. •+,`� A 4 . JEFF A. GASTALDI, R.L.S. IT IS THE RESPONSIBILITY OF THE OWNER TO •• ,`V;• ' . 4726 WEST 88T1-1 AVENUE DETEENAINE THE EXISTENCE OF ANY NTS OR RESTRICTIONS WHICH DO NOTSI if 03 m �r •:� 49TH• �N �� ANCHORAGE, ALASKA 99502 COV 0 PHONE 248-5454 APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA Jeffery A DATE HEREON BE USED FOR CONSTRUCTION OR FOR ( s •. LS-6091 ,° GRID ESTABLISHING BOUNDARY OR FENCE LINES. 1. .,*. c., . a � 3336 9/28/2004 . . essiona� °�s. ANCHORAGE RECORDING DISTRICT, ALASKA ','�,,.� F B JOB NO. 04-11 SVE33 NOTE: NO CORNERS SET THIS DATE. l�yi ,1h2: 6 ANA csLa Municipality of Anchorage *AE Development Services DepartmentBuilding Safety DivisionOn-Site Water and Wastewater Program 4700 South Bragaw St. ,kil.. � P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 dM 10 CERTIFICATE OF HEALTH AUTHORITYAPPROVAL FOR A SINGLE FAMILY DWELLING Parcel I D. b.7U1-?,Z HAA#i��� Expiration Date: 'j9`caLC)`'+ 1. GENERAL INFORMATION Complete legal description Lot 3 Block 3, Susitna View Estates Subdivision Location (site address or directions) MU) Aries CourtA-f.YAD9±9-ii At. Clq'51(4 Current Property owner(s) Merit Homes Day phone 30M280 Mailing address P.O. Box 111982 Anchorage, AK 99511 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four 4 3. TYPE OF WATER SUPPLY: TYPE OF. WASTEWATER DISPOSAL: Individual Well ® Individual On-site Individual Water Storage ❑ individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ j The Municipality of Anchorage Development. Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval'are required for the.transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C'well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a'period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEiiFiEt4T OF INSPEC 1ION BY Ef.l^viNEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in, effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 10/212004 ' �� MICHPEL E ANOERSfBi l% 5. DSD SIGNATURE =r —Z Approved for �_ bedrooms. p��.... •• Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist -X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By:. Original Certificate Date: 16 1 9 (Rev. 12/00) 1Vt4pKipatity of Anchorage Development S6Nioes,Department Building Safety Division �h-Site Waryer& Wastp�+,atPr"Program E T Y 3rC w Q . w.�. ............ . mu,. ., .. _. �' ox 196�a0 F�ric ,o age AK 99519 6650' ci anchorage a1c us EALTH UTHORITY APPROVAL CHEGKLIST 091 r � v cnp ion o 3 oc u�wes ub Ivlslon eC7 020 3 °?i`,_ ��rlva'�e f o��"provl e VVSID # ell Log (IMY MTMMMMMMM p�efec( tl 4 x Sam ary sea_ 1 N) rres���'e.P�y pro ecteSi (�'Mj S' 2 7 Case o �asmg �eig a ave groun '4 in dn. � .„ .. u� ,..y %m"> �rf^?+,a, ,ya ;ix^•..a m ;=r s %r't.='w-s „at' a a?'a'S° "�'�` � k p� v .us n ;r ,A`MPI F RFSI11 TS _,colome 00 m ifra�e mg's er a ena 0 co�onle 1tlb ml ILLY YI1 � R s�"�P�,``�"ssMUM �%�.�....,,K;�sb-�.��k� 0 13'-15 o�ra6nq (q p/ff or ft /bdrm) .6 GPDISF System type Deep Trench ft. Gravet belowpI e 9 ft. p _ . a sprp ion area _y_ Monitp�jDg tube Y. Depressron•oyer I�i� t� 6edr6oou)0 :. tes : esuls (pass/ al For _bms Al ,� w!';e'^nM"�'s'wY�,'3`irji ' ,ro enm inn =c v me 4oet to WaTPf AtltlPfi OAt NeW r�Ep�l . in. ' V nspections and'wg� (stems are in • fect on this date !" ......... ; k MICHAEL E ANDERSON''■. on,11 PE,..,1 S� No. CE 4381 �r Waiver Fee $ '4 115. cxk nt I C i t c Date of Payment )r Receipt Number IL �, a£t�53itY �%;✓+ t �`��s.'t1",i�5,�'' "e � 'k n „^z ."t p ,GS Ref.# 1046171002 :IientName Anderson Engineering ?rojectName/# Various aient Sample ID Lot 3, Block 3, Susitna View vlatrix Drinking Water ?WS1D 0 Sample Remarks: Results PQL Waters Department Nitrate -N 0AOO LI Microbiology 'Laboratory Total Coliform 0 All Dates/Times are Alaska Standard Time Printed Date/Time 09/24/2004 14:23 Collected Date/Time 09/19/2004 17:30 Received Date/Time 09/20/2004 10:20 Technical Director. �, Stev?)/,C. Ede 'Allowable 0.100 mg/L EPA 300.0 D (<=10) co4/160tnL SM2092228 A (<=1) Analysis Inil Date 09/20/04 JJ$ 09/20/04 DKC 150-d 50/£O'd 91£-1 IOE51951O6 S30IA83S AN3 SOS 'IS3 3913400 Nd8V:8O VO -VZ -60 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 October 2, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 3, Block 3, Susitna View Estates Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The absorption trench for Lot 3, Block 3, Susitna View Estates Subdivision is located approximately 2' from the south property line to provide as much separation from the open ditch flowing through the property as possible. The terrain of the lot is difficult to place an absorption trench and the location utilized is the only area available which is more than 100' from the ditch which contains water at various times of the year. Placement of the new absorption trench at the location shown will not impact wells or adjacent septic systems. We therefore recommend a waiver be issued allowing the new trench to be constructed at 2' from the south property line. Sincerely, Ejlt — l Michael E. Anderson, P.E. Municipality of Anchorage a !W P if t fti�•�' T P.O. Box 196650 • Anchoragc„ Alaskat 995196650 • Telephone (907),'343-8301 • Pnx (907) 343-5200 4700 Bragaw Strcet • Anchorage, Alaska 99507 ` r` wm�c. mami.org !Magor Mark Begich Building Safety Division 10/19/2004 Anderson Engineering P.O. Box 240773 Anchorage, Alaska 99524 Subject: Waiver Request for Susitna View Estates Subdivision, Block 3, Lot 3 Waiver Request #WR040076 Parcel ID #020-091-32 HAA# HAO40517 Dear Mr. Anderson: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to property line has been approved. The approved separation distance is 2.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, Julie Makela, P.E. Civil Engineer On -Site Water & Wastewater Program Community, Security, Prosperity