HomeMy WebLinkAboutGLENN VIEW ESTATES NORTH BLK 1 LT 5Estates North
•
#051-821-18
Municipality of Anchorage
Development Services Department Pegs of 3
On.SRe Water and Wastewater Program
4700 South Bragaw Street
P.O. Box 196650 Anchorage, AK 995196651)
www.d.anchorage.ak.us (907) 3437904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number. SWO40066
Nrna: PID Number. 051.821-18
S inell Homes Wastewater System: New
Addl.u:
1900 W. Northern LI hts Ste. 200 Anch. AK 99517 ABSORPTION FIELD
78 wrlb.r"esaaame;
Four 4 5' Wide Trench
LEGAL DESCRIPTION a°" PAng
45 WD/FP TON r om ananN we*
taatic La: acwuia,,: 5.5 pips: Ft.
1 5 U b pps aoln bmn arp"w Pett: Ornbl dh b
epaneelh
Glennview Estates North 1.5
Tawulyp: Section: IN aww Nwve OWW Peds: Ft. Ft
1.3 cr"vN t..r,ah.
4
Well; R• 136 Ft.
AWWUWater3ystem �"°""'"°"`
of UM: e1e
5 b avaen WWI.
cw.a� bn 1, A e. cr. 10 Ft.
TON OaPRr Ceeed b: dal lraa. FL 2 >
Dnllar: "• FE 1,360 Rte ASTM 8034 PVC
oN. Dri"ed: staft weber l ;
r,.b,ny Ft Palsano's Dirtworks 5/20.21/2004
PusN It: C=wQ Nwva OrouN:
wM p' ct. TANK
SEPARATION DISTANCES ® septic ❑ Holds
ng To Soptic Absorption Lin Holding dklPmate ❑ S.T.E.P. ❑Other.
From Tank FkH Station Tank sewer Line Anchorage Tank
V%" >200' >200, WA NIA >25" 1,250
Steel TWO (2)
La Uw >55` web. >100, >100' WA NIA LIFT STATION - NONE ON LOT
LNL » >10, WA NIA
nN.
Fauxle, n >T >10, WA WA ""pan uap
in.
can«, D,*n None Noted Pwo . b. r . _ . " In.
BENCH MARK
Floor.
Inspections performed by: . Kimbrou h Dates: 1"_ 5/20/04
Department of Health and Human Services approvai5i21/04
Reviewed and approved by:
pkw IQ") Date:.l k-, /D- c� �
100.0 Ft
Engineer's stamp
�£ 4$th
MICHAEL E. ANDERSON
NO. CE -4381 j
Municipality of Anchorage -
4700 South Bragaw Street Anchorage, AKP99519-66 5 - 343-7904
On -Site Wastewater Disposal System or Well inspection Report
Permit Number. SWO40066
NORTHWOODS CIRCLE
0
M
15' T. # E.
0 49th !V
MICHAEL E. ANDERSON
No. CE -4381
I�LAN AS -BUILT
SCALE 1" = 50'
Page 2 of 3
PID No. 051-821-18
J ESTATES NORTH
i, BLOCK 1
45,684 S.F.
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT Page 3 of 3
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: SWO40066
PID No. 051-821-18
n
. /—'96.53 95.90
/ F U
Geotextile Fabric
Dralnfleld Rock 2.70
80.1
PROFILE AS -BUILT
Scale: 1' = 20'
E�
I-
2
3
4
5
6
7
8
9
10
11
12
14
15
16-
17-
18-
19-
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES, DEPARTMENT
4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION• L 5 B i GLENN VIEW ESTATES NORTH S/D w
G
PERFORMED FOR:_�PINEI I HOM C In1r
DATE: 5/20/2004 PROJECT No -
PARCEL IDS TECHNICIAN: T.L. KIMBROUGH
p 7—� TEST HOLE # 2 Type of Test: ® Percolation
l/ / /l OG/PT
2%
SILT WITH GRAVEL
ML
DENSE
DRY
m
WAS GROUND WATER ENCOUNTERED NO
k YES ® WHAT DEFTH
DEPTH OF WATER AFTER MONITORING ONE 2%
DATE OF MOWTORtNG -5/30/04
F ------
MEL E M10ERSM
NO. CE -4381 J
PERCOLATION RATE; 48 NIN4INCIO FERC. HOLE DIA• 6 rIlJCHES)
TEST RUN BETWEEN• 4 5 FT. and_5,tFT•
COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE
TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 10/21/04
Permit Number: SWO40066
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water& Wastewater Program
4700 South Bragew Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Legal Description: VfW_&jU="-j Orth BlockltL;k§,
Design Engineer: 0014 Anderson Engineering
Owner Name: Spinell Homes, Inc
Owner Address: 1900 W. Northern Lights Blvd., Ste 200
Anchorage , A 99517 -
C -z 0-0[(-
s /ZI J oc,— l 0-0_�
/6:0,0
Date Issued: Apr 20, 2004
Expiration Date: Apr 20, 2005
Parcel ID: 051-821-18
Site Address: 23500 Northwoods Circle
Lot Size: 45684 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
S�S�oy- DtsryN chwn.SE i S." sake "9'V/4'tr'u Mt010 '*Vo New sine G/A4/
DATCP / VVI VY.
Received By:
Date: 4-ZV - 0
Issued By: r1'I ►" Date: 10 0
Municipality of Anchorage
• Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 6!43 051 -82 -1 -IS Permit Number SW
Property owner(s) Soinell Homes, Inc. Day phone 344.5678
Mailing address (1)1900 W. Northern Lights Blvd., Suite 200 Anchorage AK 99517
Mailing address (2) Zip Code
Legal description (Lot, Block & Sub'd.) Lot 5. Block 1. Glennview Estates North Subdivision
Legal description (Section, Township & Range)
Lot Size 45.684 SF Acres/Sq.Ft.
THIS APPLICATION IS FOR:
Number of Bedrooms Three (3)
Sewer Only ® Well Only ❑
Sewer and Well ❑ Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees:
Date of Payment:
Waiver Fees:
Date of Payment:
Receipt Number.(tLOReceipt Number.
(Rev. 12!00)
ANDERSON ENGINEERING,
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 522-6779 FAX
MEMO
DATE: 5/4/2004
TO: Joe Goodall
WITH: MoA/On-Site Water and Wastewater
FROM: Mike Anderson
SUBJECT: Lot 5, Block 1, Glennview Estates North Subdivision
Septic System Permit Number SW040066
The homeowner has upgraded the house proposed for this lot to 4 bedrooms. We
have revised the site plan and design for the septic system accordingly. Additional test
holes will be placed prior to construction to verify the subsurface soil conditions on the
lot. Please modify the permit to allow for a 4 bedroom septic system on this lot.
Please let me know if you have additional questions
100' N
15' T. k E. ESMT--
9th
�...................
REL E. RMDERSi
No. EE -4381
NORTHWOODS CIRCLE
0
M
99.58.04-E R,
27.04' Lai.2 J8 .
____�` �4•�52'
99'
F- + 5/8' REBAR (TYP PER PLAT)
r
I
WAGE
96.
Throe Bedroom
Home xT
0a % ad
To
TM
RzaRe'• so
i
I
45,684 S.F.
SITE PLAN
-444wrLFMl ulls'aw*W- — SCALE 1' = 50'
LOT 5, BLOCK 1, GLENNVIEW ESTATES NORTH
80'
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 522-6779 (FAX)
April 16, 2004
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 5, Block 1, Glennview Estates North Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 5, Block 1, Glennview Estates North Subdivision intends to construct
a three-bedroom home on the lot. We are therefore requesting a permit be issued for
the construction of a new septic system to serve the new home. The subdivision is
served by a community water system and no conflicts exist with adjacent septic
systems or wells. The attached Site Plan and backup documentation identify the
location and configuration of the proposed septic system and alternate site. Existing
spot elevations and the Current drainage pattern are identified on the Site Plan. The
drainage pattern will be maintained after development of this lot is complete.
A test hole placed on the lot during the subdivision phase indicated silt with some gravel
in the area of the absorption trenches. The accepting soils were tested and found to
have percolation rates of 44 minutes per inch. No groundwater was found during
excavation and none was noted during the monitoring period. The test hole is more
than 30' from the new trenches and we are proposing to provide acceptable test hole
data prior to the construction of the new system. Acceptable soils logs and percolation
test data will be provided along the inspection report and certified as -built for the new
system. Our design includes the placement of a new 1,000 -gallon septic tank along
with 2 - 50' long by 5' wide by 4' effective depth absorption trenches to collect and treat
the sewage generated in the house. The bottom of the trench will be 5.5' below the
surface. The distribution pipe will be 1.5' below the surface. A flow splitter valve will be
placed to assure even flow of effluent to each trench. A minimum of 3' of cover will be
placed atop the trenches and a minimum of 4' of cover will be placed atop the new
septic tank.
Lot 5, Block 1, Glennview Est North
April 16, 2004
Page Two
The ground surface on the lot slopes at grades sometimes greater than 25% from east
to west as shown on the Site Plan. The absorption trench will be constructed parallel
with the slope of the ground surface as much as possible in conformance with
Municipal requirements. The new septic system will be constructed a minimum of 100'
from the well proposed for the lot and on adjacent lots. It will also be constructed a
minimum of 100' from any surface water in the area.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
. in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
74'1� Ea4'
Michael E. Anderson, P.E.
Attachments
MICHAEL E. ANDERSON
No. CE -4381 _+
NORTHWOODS CIRCLE
0
M
100' N W58b4'E R,
27.04' l�lB
15' T. R E. _ 4ftso 00' =—J
—_�QV
N.52' 5/8' REM (TYP PER PLAT)
o
� I
s
.I
Thee Bedroom }
Nome
to
91
Cot ® Ne=ptlen Tnn'Lr
p� 711
U ` W N
O
I
e' J
45,684 S.F.
PSE•'""' • N�
� ss.ao•
a to '' 1
.�SITE PLAN
lksn
trr SCALE V = 50'
LOT 51 BLOCK L GLENNVIEW ESTATES NORTH
LOT 5, BLOCK 1, GLENNVIEW
ESTATES NORTH SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Three Bedroom House 5' Wide Trench System
Pero. Rate: 44 Min.Anch 1,000 Gallon Septic Tank
Application Rate: .45 GPD/SF 4' Drainfiekl Rock
3 Bedrooms X 150 GPD/.45 GPD/SF (application Rate) = 1,000 SF Absorption Area
1,000 SF/5 SF • .5 (Red. Factor) = 100 LF Trench Length
THEREFORE: Construct Two 50' Long x 5' Wide x 4' Effective Depth Absorption Trenches.
Flow Line Elevation in Trench to be 1.5' Below Original Ground Surface. Total Depth to be
5.5' Below Eodsbng Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over
Absorption Trench. Provide Flow Splitter Valve to Assure Even Flow to Each Trench.
1'0"
0
4'0"
YPICAL
Natural
Backfill
Geotextile
Fabric
4" Perforated
PVC (Holes Down)
Drainfield Rock
DE TRENCH SECTION
.err..•--••.�,�t
NOTE: Grade Area Over Trench to Drain Away.
Minimum 0' Separation From Bedrock. 4
Minimum 4' Separation From Groundwater...
Minimum 10' Separation From Water Services in the Area- i`'`;{�•
Minimum 100' Separation From Surface Water or Streams:No. CE.,,,
Depth
7
DIL&ANi a -PT-
Lr,
PTLT, ML
9-
1 '5-
14-
SILT ML WAS GROUND WATER
Municipality of Anchorage
6(ENS(
Development Services Department
Ni
ER's;
l'
Building Safety Division
11 _
Depth to Water After
o
0
On -Site Water and Wastewater Program
9r� P
E
12
Date:
12.4 01-
L
4700 South Bragaw SL
P.O. Box 196650 Anchorage, AK 99519-6650
o�,,.,.,,
www-ct.anchoraceaku$
Tcb 1-�u�ztond
(907) 343.7904
- 4
ii�•.r� Cc -'1125
Soils Log -Percolation Tests;�,`p
�c ay oval ,\
Performed For: %'LEJJVIEt>' Nr�RTF-ir)
Date Performed: f f 6 0
Legal Description: _L07 - Township, Range, Section:
Depth
7
DIL&ANi a -PT-
Lr,
PTLT, ML
9-
1 '5-
14-
SILT ML WAS GROUND WATER
Drop
ENCOUNTERED?
ND
10 -Vat,
�l IF YES, AT WHAT DEPTH?
s
L
11 _
Depth to Water After
o
-
Monitoring?
9r� P
E
12
Date:
12.4 01-
L
1'5-
14- Reading Dale
1s- FILL 71
16- b'7/e,
17- _ 3L-
19 -
PERCOLATION RATE
COMMENTS TEST RUN BETWEEN
(minuleYiMn)PERC HOLE DIAMETER
FT ANDJS '/2- FT
PERFORMED BY: � � s ( ^S
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DACERTTE. FY THDATE: AT !S TE_122.9'/02-
WAS
Drop
b
oNetTimeDe4WaterNei
IOx'11
(minuleYiMn)PERC HOLE DIAMETER
FT ANDJS '/2- FT
PERFORMED BY: � � s ( ^S
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DACERTTE. FY THDATE: AT !S TE_122.9'/02-
WAS
ONSITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT S, BLOCK 1, GLENNVIEW ESTATES NORTH SUBDIVISION
GENERAL:
The scope of this project includes the procurement and placement of a new
1,000 -gallon septic tank at the location shown on the Site Plan. Work also
includes the construction of 2 new 50' long X 5' wide X 4' effective depth
absorption trench at the location also shown on the Site Plan. The
distribution line in the trench will be placed at 1.5' below the existing ground
surface. Total depth of the trenches will be 5.5' below the existing ground
surface. A flow diverter valve must be placed to insure even flow to each
trench. The new septic tank and absorption trench must be placed a
minimum of 10' from the water service on this and adjacent lots. In addition,
a separation distance of 100' must be maintained between the septic tank
and absorption trench and any surface water.
2. Construction shall be in accordance with the approved site plan, design
drawings, Municipal Permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the location
of all lot lines. The Contractor must also verify the location of wells in the
area and assure that the separation distances are met.
4. Unless specifically agreed otherwise, the contractor shall be responsible for
final grading areas subsequently depressed from soil settling. Property
owner shall be responsible for revegetation of affected areas unless
specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified by the
Municipal Department of Health and Human Services for system installations.
Owners installing their own systems must receive prior approval from
D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
A new 1,000 -gallon septic tank must be procured from an approved source
and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
Lot 5, Block 1, Glennview Est North
April 16, 2004
Page 2 of 3
3. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches above
final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial
insulation.
6. A foundation cleanout shall be installed one to four feet from the building
foundation. Two cleanouts are required between the tank and the drainfield.
7. Final grading over the tank shall be such that a positive slope exists away
from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the design.
The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a level
bed of drainfield rock. Rock should then be placed over the pipe to provide a
minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield rock
and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations shown on
the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum 100' away
from any private water wells in the area, 150' from a Class "C" Well or 200'
from any community well
6. Direct bury insulation must be placed over the distribution system if less than
3' of backfill depth is available. Finish grade over the trench must be
mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for a 5'
wide trench. Contractor shall verify this condition prior to placement of the
rock. All pockets of unacceptable materials must be removed and replaced.
• "' Lot 5, Block 1, Glennview Est. North
April 16, 2004
Page 3 of 3
MATERIAL SPECIFICATIONS:
Septic tanks must be constructed by a Municipally approved septic tank
manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and
solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662
or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.'
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the
#200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These inspections
must be conducted under the supervision of a professional engineer registered
in the State of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled.
The second inspection must be conducted after the placement of the geotextile
fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No
backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction notes
for use in preparing the certified as -built of the completed system.
MUnicipaIity of Anchorage It j16)
•, '-f Development Services Department
Building Safety Division °
On -Site Water and Wastewater Program `
4700 South Bragaw St. ' • FTT
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907)343-7904
CERTIFICATE OF. HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. C51.821•18 HAA #
1. GENERAL INFORMATION Expiration Date: u=/ a jg'
Complete legal description Lot 5 Block 1i Giennview Estates North Subdivision
Location (site address or directions) 23500 Northwoods Circle1�5Lo�
Current Property owner(s) _Spineil Homes. Inc Day phone 344-5678
Mailing address 1900 Northern Lights Blvd. Anchorage AK 99517
Lending agency Day phone
Mailing address
Real Estate Agent Day phone
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup.
2.- NUMBER OF BEDROOMS: Four 4
3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
individual Well ❑ ' individual On-site
Individual Water Storage 0Individual Holding tank
Community Class Well 171. Community On-site
El
Public Water System ® Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results less than 30 days old, (Certificates may be reissued for a period of up to one year with
valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water
system_ The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's
work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-
site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
'wastewater disposal system is(are) iri compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm Anderson Engineering Phone 522.7773
Address P 0 Box 240773 Anchorage AK 99524
Engineer's Printed Name Michael E. Anderson P.E. Date 111312004
_ .$+r �n,
5. DSD SIGNATURE
V Approved for 4_ bedrooms.
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
Additional Comments
,1006..
? , AN.SffE
Ea WATER
.� '.•° ereeTLSS1A7
v�Tc
PROGRA
J
i �. �. - JI�J/J111111F11
Attachments:
HAA Checklist X Maintenance Agreements
Septic System Advisory Supplemental Engineer's Report
Well Flow Advisory Other
By: ��j:C/� Original Certificate Date:
(Rev. 11/00)
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water& Wastewater Program
i 4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.c7i.anchorage.ak.us
(907) 343-79D4
HEALTH AUTHORITY APPROVAL CHECKLIST
I
Legal Description: Lot 5 Block 1 Glennview Estates North Subdivision
Parcel ID: 051.82118
A. WELL DATA
Well type If A, B. or C provide PWSID # _
Well Log (Y/N)
? Date completed _ Sanitary seal (Y/N) _ W resro erl
P P y Protected (Y/N)
Total depth ft,
i, Cased to ft. Casing height (above ground) in.
FROM WELL LOG AT INSPECTION
Date of test
t Static water level ft.
Well production ft.
g.p.m. 9_P.m.
f WATER SAMPLE RESULTS:
s
Coliform colonies/too mi. Nitrate mg./I, Other bacteria
colonies/100 mi.
Date of sample: Collected by:
U. SEPTIc/HOLDING TANK DATA
Tank Type/Material Septic/Steel
Date installed 512012004
Tank size 1.250 gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (YIN) N
Date of pumping Pumper New Construction
C. ABSORPTION FIELD DATA
Date installed 5/2112004 Soil rating (g,p.d./ft2 or ft%drm) .45 GPD/SF System Y type 5' Wide Shallow Trench '
Length 136 ft. Width 5 ft. Gravel below pipe 4 ft,
Total depth 7 ft. Eff. absorption area 1y360 ft' Monitoring.tube Y Depression over field N
Date of adequacy test Results (Pass/Fail)'
For ` bedrooms
Fluid depth in absorption field before test _,_, in. Water added_ gal. New depth_ in,
Elapsed Time: _ min.. Final fluid depth _ in. Absorption rate >=
g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N
If yes, give date
th
Date installed
,,Pump on" level at_ in.
Size in gallons
,,Pump off' level at_ in.
Datum
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Manhole/Access (Y/N)
High water alarm level at in.
Meets alarm & circuit requirements?
Septic tank/lift station on lot NIA On adjacent lots AYA
Absorption field on lot NIA On adjacent lots NIA
Public sewer main NIA Public sewer manhole/cleanout NIA
Sewer /septic service line NIA Holding tank NIA
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Property line >5
Absorption field >5'
Building foundation >5' P y
Water main >10' Water service line >10' Surface water >100'
Wells on adjacent lots >200'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line >10'
Buildingfoundation >10' Water main >10'
Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >5'
Curtain drain None Noted Wells on adjacent lots >200'
F. COMMENTS
Property is Served by AWWU Water System,OF
y��♦.r-------
G. 'ENGINEER'S CERTIFICATION
1 certify that l have determined through field inspections and 4` •` 49th `'• „i
review of Municipal records that the above systems are inr,
..:�..
: r
conformance with MOA HAA guidelines in effect on this date. r� c'R .etcr+�a. rr �;�RsoN
♦I No, cc3e
Engineer's Printed Name Michael E. Anderson P.E. �j s ��, -4 1
�1� pR�FESS1ai+�+•
Date 111312004 RTA���+++
HAA Fee $ S7 �° Waiver Fee $
Date of Payment //, V a Date of Payment
Receipt Number G0.7 Ts- Receipt Number
(Rev: 12100) i
i
0
2003-94
GLENN VIEW ESTATES NORTH _
LOT 51 BLOCK
45,684 S.F.
NORTHWO�_CIRCLE_
0
N 89'58'04"E R-50
27.04 L=32. js.
Rc50.00'
15' T. & E. ESM . _ 4--44.52'
r
0
2
� m
29.7
29.3'
EXISTING 3A 2 .
SUIUDING
N .�.
•
�(p,• LA
I SEPTIC SYSTEM
at .• > -
m �
u fn
rn LA
co -A
tr > ,
> -40
S 84'11'55"E " 158.00'
FINAL STRUCTURE AS -BUILT .p♦jj�
AS — BUILT PROPERTY DEPICTEDHABOVE AND THAT AT I HAVE YN THE y OF q� ��
GASTALDI LAND SURVEYi ENCROACHMENTS EXIST EXCEPT AS INDICWNE ED. i►���s••••••.,••
I R.L. IT IS THE RESPONSIBILITY OF THE OWNER
EASE ENTS c""49L yV 54 '641
JEFF A. GASTALD , ETERMINE THE EXISTENCE OF
4726 WEST 88TH AVEN C,(�,[�VENANTS OR RESTRICTIONS WHICH DO OT r�` :•••+ �•.:..a
ANCHORAGE, ALASKA 99 VC • oury A. Gostaldl Mir
PHONE 248-5454 APPEAR ON THE RECORDED SUBDIVISION LAT•Ar
UNDER NO CIRCUMSTANCES SHOULD ANY DATAP� .�,••c• �s-soar i''
DATE HEREON BE.USED FOR CONSTRUCTION 0 FOR Ar ••. e°
GR)D ESTABLISHING BOUNDARY OR FENCE LINEap°ofessiono\�o�0�`♦
NW1559 8/10/2004 ANCHORAGE RECORDING DISTRICT, ALAS A �a�!>d®�'♦
F.B. JoB No. ' NOTE: NO CORNERS SET THIS DATE.
04-08 GVEN51