Loading...
HomeMy WebLinkAboutLAKE RIDGE TERRACE BLK 6 LT 11Lake Ridge Terrace Block 6 Lot 11 #051-313-33 Municipality of Anchorage Development Services Department • °` �` Building Safety Division, On -Site Water & Wastewater Program, 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519650 www.d.andlmage.akus (907) 343-7904 Page 1 of 2 On -Sits Wastewater Disposal System and/or Well Inspection Report Permit Number. SWO10016 PID Number: 051-313-33 Nam: ROGER THOMPSON Wastewater System: ❑ New ■ Upgrade Address: 14724 TERRACE LANE a EAGLE RIVER, AK 99577 ABSORPTION FIELD Phone•. No. of Bedrooms: (907) 696-05'516 4 DDeep Trench DSholiow Trench Deed DMound DOther LEGAL DESCRIPTION Sol nounip '°�' tvo/se. R R Lot: BbOk: Subdivision: 11 6 LAKERIDGE TERRACE Dept: to ppm bottom wan prpinol erode OravN beneath pipe Township: — Range: Section: Fa added sew. arlOMel pose R R Drorl Nngt,: — — #? R R WELL: ❑ New ❑ Upgrade Draw wwiu L Number of lkm Dbtona betsm Wwe: Clarification , AAF); 'T'" Owed To:Teta oeeorPDan R R Pipe mebeem: R R $a. R Odom Dab On%& 910110 Voter IlrekDab addled: R RPC EXCAVATING 2/10/2001 fiats: puns sat At Desire heightActor Ground: VMR R TANK SEPARATION DISTANCES - ■Septic 0Holding 0S.T.E.P. 0Other To Teptk �Flwdan Uft Ho'dZg 0-pcosT inoouomn From Station saw truss ANCHORAGE TANK 1250 well 100'+ — — — 25'+ �'• STEEL Number a compartments: 2 Surface water 100'+ - - - - LIFT STATION Lot Line 5'+ — _ _ _ sae In sallow: Monuracteer. Foundation 5'+ _ _ _ _ co WW at p air mini water sowm sir Curtain Drain NONE KNOW P MMaw k �ee1ea1 biroectlene per7°n wd y' emarks: EXISTING SEPTIC TANK WAS CRUSHED BENCH MARK AND BURIED ON SITE lsootbn and Drorlplore TOP OF HOSE BIBB Assumed Elevation: 100.00 R mrrrsrtaes epu\u '. 0oo604Q� ���F.. • s�4p Inspections Performed by. AWWC, INC. Dates: 1st 2/10/2001� 4 .�.:... .. ....... 2nd 2/12/2001 Q e r A. Garness•� ' Department of Health and Human Services approval Popgv •• 7953 e` Reviewed d and approved by: Dater •27-o/ 4�Qa Prafessb��dc'� ALTERNATE SITE. 20' X 16' r----1 BOTTOMLESS INTERMITTENT SANLIFT D L 5 REQUIRE STATION ANDD AND I I \ LOT LINE WAIVER. I I \ a .t z I A I ZP OF TMX AT N.ET95M / I ��92T5 ALASKA WATER & WASTEWATER CONSULTANTS, INC. 6901 DEBARK ROAD, SUITE 2B - ANCHORAGE. AK 99504' FHOIIE (907;337-6179 - FAX (907)336-324 PREPARED FOR: PHONE NUMBER: ROGER THOMPSON (907) 696-0516 LEGAL DESCRIPTION: LAKERIDGE TERRACE SUBDIVISION; LOT 11, BLOCK 6 TYPE OF WORK: AS -BUILT OF SEPTIC TANK UPGRADE FAVL am 9751+/- I 52 NEW 070 CKLON 5MC TANK !/12/200 WN BY: J.L.M. LE: 1"=30' E NUMBER: 2OF2 Arauf - 95511 ATOXtr- 9256 1 ALASKA WATER & WASTEWATER CONSULTANTS. INC. IQVIL LVb rCRLVLAIIVN ItJll LEGAL DESCRIPTION: LAKERIDGE_TERRACE SUBDIVISION; LOT 11, BLOCK 6, PERFORMED FOR: ROGER THOMPSON DATE: 696-0516 (f 1 8 y TEST HOLE #11 GM/SM 9- 10- 11 1011 12 13-1 14- 15- 16- 17- 18- 19 41516171819 20 COMMENTS: DATE I#];fi SEE AS -BUILT DRAWING DATE I,SOIL CLASSIFICATIONS NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) GW ORGANICSGP111111111ML OR PRIOR ' I 11:111!11%//%CL NNH • 12:29 - 6" MH 2 %//%CH 30 2-3/4" 3-1/4" �1lllltl� •Sc 12:59 - 6" - GM/SM 9- 10- 11 1011 12 13-1 14- 15- 16- 17- 18- 19 41516171819 20 COMMENTS: DATE I#];fi SEE AS -BUILT DRAWING DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) PERC CAVIrY PRESOAKED PRIOR 10 TEST. 2/9/01 1 12:29 - 6" - 2 12:59 30 2-3/4" 3-1/4" 3 12:59 - 6" - 4 1:29 30 3" 3" 5 1:29 - 6" - 6 1:59 30 3" 3" PERCOLATION RATE 10 (MIN./INCH) PERC. HOLE DIA. 6" (INCHES) TEST RUN BETWEEN 5.0 FT. AND 5.5 FT. PERFORMED BY ALASKA WATER & WASTEWATER I, JEFFREY A. GARNESS, CERTIFY THAT THIS IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On -Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Feb 06, 2001 Expiration Date: Feb 06, 2002 Permit Number: SW010016 Parcel ID: 051-313-33 Legal Description. T*AwE TEIi� BI.k ' 6 LT 11 f ' 7 Design Engineer: 0041 AK Water B Wastewater Consultant Site Address: 014724 TERRACE LN Owner Name: ROGER THOMPSON Lot Size: 19400 SQ. FT. Owner Address: 14724 TERRACE LANE Total Bedrooms: 4 Permit Bedrooms: 1 EAGLE RIVER, AK 99577-9243 This permit is for the construction of: ❑ Disposal Field 0 Septic Tank F-1 Holding Tank ❑ Privy ❑ Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and dosed on the same day. B. Covered, sealed, and heated to prevent freezing. TO THE CONSTRUCTION OF THE 1250 GALLON SEPTIC TANK THE ENGINEER $HALL;)-` ISTRATE TO THIS OFFICE THROUGH SOILS TESTINGIGROUND WATER MONITORING AND° , 4ING THAT THIS PROPERTY HAS THE SPACE TO CONSTRUCT AN UPGRADE ABSORPTION FIELD' Received By: Issued By: Date: 0 -- & -tom/ Date: 2 —6 ^O/ Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 051 —313 - 33 Permit Number SW 0100/6 Property Mailing address (1Ciel 577 Mailing address Legal description (Lot, Block & Sub'd.) Day phone &q16 -6611v Zip Code Legal desc iptiof voS ctiOn, Township &Range) Lot Size (-1$7-4$�—= Acres/Sg.Ft. Number of Bedrooms ti THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade EL THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Permit Fees: (139-0 • o 0 Waiver Fees: Date of Payment: 1— 31-0] Date of Payment: Receipt Number: a iD Receipt Number: (Rev. 12/00) ALASKA WATER & WASTEWATER CONSULTANTS, INC. December 27, 2000 Roger Thompson c/o Prudential Vista Real Estate 16635 Centerfield Drive Eagle River, Alaska 99577 Attn: Eva Loken Subject: Lakeridge Terrace, L11, B6. Well & Septic System Evaluation. Dear Mr. Thompson: Per your request we performed an evaluation of the well and septic system which serve the subject property. Our findings are summarized as follows: WELL: We were unable to find a well log on file at the Municipality of Anchorage, however, based upon the septic system installation records the, the well was in existence on 8/15/75 and is 112 feet deep. Per the 1984 health certificate paperwork the well is 119 feet and cased to greater than 40 feet below grade (The HAA check sheet refers to an attached letter as support documentation). The well casing height, drainage around the casing, and the encasement of the well wires (in electrical conduit) are all in compliance with MOA regulations. Prior to the start of the adequacy test the static water level was 80 feet below the top of the casing (BTC). Over a period of 243 minutes, 630 gallons was pumped from the well (2.59 gpm). During the first 60 minutes of the test the water level dropped 24 feet in the casing and remained within 1 foot of that level throughout the rest of the test. Based upon our data, the well production is at least 2.5 gallons per minute. SEPTIC SYSTEM: The septic system consists of a 1000 gallon steel septic tank (installed 8/1975), a seepage pit/crib (installed 8/1975) and a trench type drainfield (installed 6/1986). The adequacy test was performed on the trench only. On the day of the test the liquid level in the trench was 9.5 inches in one sump and the other was dry. One -thousand & thirty-six (1036) gallons was added to the trench, which caused the level to rise to 66 inches (and 54 inches in the other sump). The first 52 gallons introduced caused a rise of 6 inches in the sump, the remaining 984 gallons caused an average rise of 51 inches (19.29 gallons per inch) Eight -hundred and thirty (830) minutes later the liquid level had dropped an average of 19.25 inches, indicating approximately 375 gallons had been absorbed. This corresponds to an absorption rate of approximately 650 gallons per day, which exceeds the MOA absorption rate for a 3 bedroom �p�q�J nj�E fznerL. 4— 9&&100--4 6901 Debarr Road, Suite 2-B * Anchorage, Alaska 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246' Website: akwwc.com r house (450 gallons per day). It should be noted that the trench had to be filled to 100% of its absorption capacity in order to achieve this absorption tate. If you have any questions, please contact me at 337-6179, or visit our website at akwwc.com. Thank you for cginsidering AW WC for your engineering needs. P.E., M.S. 6901 Debarr Road, Suite 2-13 * Anchorage, Alaska 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com ALASKA WATER & WASTEWATER CONSULTANTS, INC. January 30, 2001 Municipality of Anchorage Developmental Services Department Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Septic Tank Upgrade for Lot 11, Block 6, Lakeridge Terrace Subdivision To whom it may concern: The existing 4 bedroom house is currently served by an on-site well and septic system. The conventional septic system contains a 1000 gallon septic tank and is inadequatly sized. In order to obtain a Health Authority Approval, the septic tank needs to be upgraded. The drainfield has been sized for a 4 bedroom house. We are proposing that the existing 1000 gallon septic tank be replaced with a new 1250 gallon septic tank. 1. SURFACE WATERS: There are no surface waters within 100 feet of the proposed upgrade. 2. TOPOGRAPHY: There are no slope concerns. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your P.E., M.S. NOTE: Attached is a site plan drawing, a design drawing„ and a 5 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com ALASKA WATER & WASTEWATER CONSULTANTS, INC. 6901 DE9MR ROAD, SUITE. 20 • ANCHORAGE, AK 99504 • PHONE (907)337.6179 • FAX (907)33"24 PREPARED FOR PHONE NUMBER: ROGER THOMPSON (907) 696-0516 LEGAL DESCRIPTION: LAKERIDGE TERRACE SUBDIVISION; LOT 11, BLOCK 6 TYPE OF WORK: SITE PLAN LOT 2. BLOCK 4—A LAKE RIDGE TERRACE LOT 3, BLOCK 4—A LAKE RIDGE TERRACE LOT 4, BLOCK 4—A / LAKE RIDGE TERRACE / 1 1/30/2001 pF AWN BY: K.D.W. ALE. e in = 100' ;E NUMBER: ` 1 OF 2 r A. Gal p� —7953 �s Q^s O Cp^o fessioo I'm, ss / I I I 1/ 1 I LOT 8, BLOCK I LAKE RIDGE TERRACE A I ' I � / � I I j LOT 9, BLOCK e 1 / LAKE RIDGE TERRACE I / j l L----------- I --T�------ PROPOSED SEPTIC I \ LOT 10, BLOCK 6 I TANK UPGRADE I \ LAKE RIDGE TERRACE \\ - EXISTING FOUR EXISTING SEPTIC I \ BEHOUSE SYSTEM y / LOT 1, BLOCK 4—A / �L j LAKE RIDGE TERRACE `�\ ALASKA WATER & WASTEWATER CONSULTANTS, INC. 6901 DE9MR ROAD, SUITE. 20 • ANCHORAGE, AK 99504 • PHONE (907)337.6179 • FAX (907)33"24 PREPARED FOR PHONE NUMBER: ROGER THOMPSON (907) 696-0516 LEGAL DESCRIPTION: LAKERIDGE TERRACE SUBDIVISION; LOT 11, BLOCK 6 TYPE OF WORK: SITE PLAN LOT 2. BLOCK 4—A LAKE RIDGE TERRACE LOT 3, BLOCK 4—A LAKE RIDGE TERRACE LOT 4, BLOCK 4—A / LAKE RIDGE TERRACE / 1 1/30/2001 pF AWN BY: K.D.W. ALE. e in = 100' ;E NUMBER: ` 1 OF 2 r A. Gal p� —7953 �s Q^s O Cp^o fessioo I'm, ss / I I I 1/ REMOVE IXISIING SEPTIC TANK AND INSTALL REPLACE WITH A DOUBLE NEW 1250 GALLON 1 1 CLEANOUTS \ SEP11C TANK I 1 qjIXI5S SEPDC ... DATE: oQOQp�� 1/30/2001 o F OQ !c�u 1 �IL�loe msl emenl DRAWN BY: :s44 ALASKA WATER & WASTEWATER K ° "' CONSULTANTS, INC. SCALE: c 30� k.:. ' "" ...S�t Y�/ 6901 DESARR ROAD SUITE 2B • ANCHORAGE AK 99504' FHONE(907)337-6179' FAX (907)330-3246 NI PREPARED FOR. PHONE NUMBER: PAGE NUMBER: (��/ ROGER THOMPSON (907) 696-0516 2 OF 2 Q j fro A. ess. � F LEGAL DESCRIPRON: QO -7953 9` LAKERIDGE TERRACE SUBDIVISION, LOT 11, BLOCK 6 QQm .Fg TYPE OF WORK: ��s^�dprofesslcn��o�' DESIGN OF SEPTIC TANK UPGRADE ���40poo�Q MUNICIPALITY OF ANCHORAGE Dvr—RTMENT OF HEALTH AND HUMAN SER'~'ES Environmental Health Division 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT i2 .� ,S Name erg DISTANCES FROM TO SEPTIC TANK ABSORPTION FIELD WELL Address %/0 Q/ii ! f r �t l< sf°.+vidr 955 WELL /Orf Aol '� r PhonPhones)w Permit No. No. of Bedrooms — LOT LINE .35-1 5 LEGAL DESCRIPTION Lot /V Block 6 Subtlivision Leif 7?1­r Ce FOUNDATION 4S00` 6p7 Township. Range, Section S N a arl S AS -BUILT DIAGRAM (Show location of well, septic system, property lines, foundation, mac • driveway, water bucks TANKS p CR SEPTIC ❑ HOLDING Manutacumeyr Capac ty in gallons EXrJr/N at N/fN /49i,9 Material No. of Compartments f S1-tt/ TYPE OF SYSTEM a yRENCH ❑ BED El W. DRAIN El OTHER M rialet(g : Depth to pipe bottom from Total depth from original grade Z original grade FT 9 FT � Fill added above original grade Gravel depth beneath pipe FT 6 FT Gravel length Gravel width area .�? SZ SQ FT.� FT Number of hoes Soil rating 2Ywr pipe material SO FT q T,., 3v 3,V JI0 Installer Date Installed �rr 6i'%1 .6,11 F/.o 6- WELLS f PRIVATE ❑ OTHER (Identity) Classification (A,B,C) Total Depth Cased to P� NATE �l S FT ton � FT Installei Date Installed; Lt.✓ArrJ Axiillli Fi REMARKS: o(� trr.ai AGN c�. a.Io�t-o�.. 4r r Scale: . OWr✓6r %iarJ QJba•r/f j wiai {av Inspections Performed by. bDle Rfyer Efullatorin.Services' 4 Yse(L Date P. P. Pax 773261 Eagle River, AK M71 ci 3 B. re. 7Atlj?S 894-5195 I !�? /certify that this inspection was performed according to all Municipal and State guidelines in effect on this dale: ��j Y6 11P1=`At4='vED Ili 1 -6115 SEDRoona.S otilt}/ Health Department Approval: "4� Date: rz-ura Nissl �A Louis A. Bolero ' : Z!4 CE -6736 .a Liv 74 per f fd CIS kr N % N 31:—r 4 0 BJN AS eo - S.4 So 1,491—H YWOVP-oo, Lou i CE 00. '*ROF Wr ;or -491H 4� jo. io WJ4.4�0 it.Va"Um C , No. LS veFS 1. S-33 U X 3L.r hereby girtify that LOT BLOCK L Ar nchorage,,Recording District, A aska has been y me and hat no encroachments existexcept as shown' hermon. It Is that,1,`ti Ch esponsibility of the,owner to,determine the*existence-.o a sementsi covenantsp�.:or restrictions which do not pp n the �u ecorded subdivision plat. Listed, distances prevai- l a a ascaling hould not be •attempted, to determine,unshown dimensions. This,— urv*j,1,s*not adequate for, nor should it be used foPh stab.. shing, boundary .,ir.fence lines. -ATE DRAWh 0 1 EAGLE RIV "3 ENGINEERING SERviCES INC. P. 0. Box 773294 EAGLE RIVER, ALASKA 99577 Phone 694.5195 JOB A" e /"i .$Cc, c� .iy1t e SHEET NO. / OF 2 CALCULATED BY DATE CHECKED BV DATE_ rwucri l1.., a . A own. EAGLE RIS ENGINEERING SERviCES INC. P. O. Box 773294 EAGLE RIVER, ALASKA 99577 Phone 694.5195 JOB loth Tisy �iw sca P sys�c r SHEET NO. OF 'Z CALCULATED BYDATE CHECKED BY DATE_ ml ,m mai. SCALE yr'; of G/tsi✓oA. �'_fo c -u tiot.s ..... ....... 014 ........... 41 - r ♦ }r 0 iPnG� ®�Y��4i�• • 9� � ¢� Louis i1...flDfSfQ . : CO -6736 l t4 "ROFESSIONP ml ,m mai. June 2, 1986 w la MATANUSKA ELECTRIC ASSOCIATION, INC. P.O. BOX 1148 PALMER, ALASKA 99645 David G. Berry 1710 Blue Spruces Lane Eagle River, Alaska 99577 Re: Encroachlrent into electric utility easement Dear Mr. Berry: Matanuska Electric Association, Inc. has no objection to the septic leachfield and any vent pipes encroaching into our ten foot utility easement along the back lot line of your Lot 11, Block 6, Iakeridge Terrace Subdivision. This non -objection is conditioned by the stipulation that Matanuska Electric Association, Inc. will be held harmless from any and all damages that may result from the existing and future use of the easement. If you require additional assistance, please contact our office. Sincerely, David Ingalls Real Estate and Properties Officer ALASKA'S Fill^I RFC--wjcoRPORATED 1941 -ENERGIZED 1942 TELEPHONE 1907) 7454231 MU" I Q�F•AL I'TY C) F= ANC/^ACIFCACaE DE:PARTMEN. OF HEALTH AND ENVIRONMENT#„_ PROTECTION 825 L STREET, ANCHORAGE, AK 99501 264-4720 CI N -- E3 I T E E3 E W A F2 F• E= F=< M I -r PERMIT NO: 860165 UPGRADE DATE ISSUED: 06/11/86 APPLICANT: DAVID BERRY �-mf 1, ,e s�fia••<k �a v� ADDRESS: 1710 BLUE SPRUCE fm Ste. EAGLE RIVER, AK 99577 CONTACT PHONE: 688-3443 LEGAL DESCRIP: SUBDIVISION: LAKE RIDGE TERRACE LOT: 11 BLOCK: 6 SECTION: 25 TOWNSHIP: 15N RANGE: 2W LOT SIZE: 18000 (SQ.FT. OR ACRES) I certify that: 1. I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage (MOA) and the State of Alaska. 2. T will install the system in accordance with all MOA codes and regulations, and in compliance with the design criteria of this permit.' 3. I will adhere to all MOA and State of Alaska requirements for the set back distances from any existing well} wastewater disposal system or public sewerage system on this or any adjacent or nearby lot. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE ELECTRICAL WORK MUST BE DONE BY A LICENSED ELECTRICIAN. SIGNED \ DATE: APPLICANT: DAVID BERRY ISSUED BY --- ------------------- DATE. .4 3 8�roo .� l%Ps�r a.11t Sc.e 4�gi V 1e Cr"�s S�¢ �i cc�{� p 2 E E- 6� G qq&: �?-•-sem., �r 4,/,.e 2.5 ¢ 1 C&•,e�t. -fbtn.( oFgPtc� -- S.o f,6 C�v�.-.�'�l Iso lci..._tt ennd. 6 c_ti yaQ S n Ti'titic S{�L � !,'cQs�- �� ��-IIOKCy 1✓�- (,PKC �!>I I i'40•T I'� —� �'T :J �'N/I�.A� W`�-_� �/ [�/J! 6.7 ¢+.0 l .ti cel• . EAGLE RIVER ENGINEERING SERVICES Lou Butera P.E. P.O. Box 773294 Eagle River, Alaska 99577 Telephone (907) 694-5195 M47 28, 1986 Mr. Steve Morris Civil Engineer, On-site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 REF: Lot 11, Blk 6, Lakeridge Terrace Dear Mr. Morris: The enclosed application is submitted for issuance of a septic upgrade permit for a 4 bedroom home useage on the above referenced lot. The permit to upgrade will require a 51_ lot line 'setback for the trench due to lot dimensions and in ,order to satisfy setback requirements to local wells. This lot line setback will not impact any septic system installation to the West as this land is owned by the Municipality and is being used as the route for the Eklutna pipeline which is located approxi -mately 100' west of the lot line. The trench location will be on property and permission is being obtained from utilities for location in the easement as shown on the attached site plan. It is also noted that the new trench is to be placed 12' from the existing seepage pit. This will not pose a problem as an exploratory test hole has shown that there is no sign of septic leachate in a test hole excavated 10' distance from the pit sidewall to a depth of 12'. This is probably due to the fairly high percolation rating of the soil. The location of this test hole is shown on the site plan. The ,additional rabsorbtion area to be added is 384 sq. ft. as the owner desires to add the maximum amount of absorbtion trench possible while the excavator is on the site. In reviewing this permit request it must be`realized.that no consideration was made in the past for replacement sites when a well or septic system was installed, this now results in our having to request variances to allow the system installation. If there are any questions or if additional information is required please feel free to contact me at 694-5195. Sincerely, Lou Butera, P.E. SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG — PERCOLATION TEST PERFORMED FOR: 4044VIA6G Ys^y / DATEPERFORMED: `sfeZ� �'� LEGAL DESCRIPTION: J -UJ �/ .�/c'�k 6i 44 ire efs4e %-erract. 7-jsw deaw Sft..A3 SLOPE SITE PLAN 1 2 3- 4- 5- 61 5 6 13 %/.so;l Sf ORGAwrc (SM) S'115 jc' v I r WAS GROUND WATER ENCOUNTERED? Alb 7a.., &Y►nn. oI'M. ja IF YES, AT WHAT �S DEPTH? 14 Date Gross Time Net Time Depth to Water Net Drop 15 15- /"' .y°.°•OeNC .bQ®`�R 1"1 16 jr- E. co ,� • .y (' 17 F ..° . / 18 �19t ........... Louis A. ButerO I p4i OaiP� CE -6736 t.'. 19 &y Reading Date Gross Time Net Time Depth to Water Net Drop S'3��� 20 LlS If dn 4d�' PERCOLATION RATE o_7 3 (minutes/inch) TEST RUN BETWEEN E FT AND 4' FT COMMENTS /77...`, t r %. Le //.+S7'a I*W 4 -dE 01 c7- cs / .. G A,, 7-, PERFORMED BY: Eagle River EnalneefBM Bliftes;- CERTIFIED BY: L4`7+ - DATE: P. 0. Box 773294 Eagle River, AK 9957T. 72-008 (6/79) 694 -SM EAGLE RIVER ENGINEERING SERVICES P.O. BOX 773294 EAGLE RIVER, ALASKA 99577 694-5195 SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM LEGAL: Lot 11, Block 6, Lakeridge Terrace A. GENERAL 1. The drawing and or site plan shall be a part of this specification. 2. All materials and workmanship shall meet the requirements of the Anchorage Department of Health and State D.E.C.. 3. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. 4 All excavations and depths are advisory and are to be verified or modified in the field by the contractor to meet MOA, D.E.0 require- ments. 5. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi -family wells. 6. It is always recommended that a surveyor locate the nearest lot line position and the location of any easements. B. DRAINFIELD 1. The septic tank outlet shall be uncovered and an additional 500 gallon tank added in series for a total tank capacity of 1500 gallons. 2. The bottom of the trench shall be level, plus or minus 1.5". 3. The total depth of the trench excavation is not to exceed 8' at any point . 4. The upgrade trench is to be connected to the existing seepage pit so that the overflow from the seepage pit is absorbed by the added trench. 5. A cleanout is to be placed between the seepage pit and the upgrade trench and between the 500 gallon tank and seepage pit. 6. The trench gravel is to be covered with typar fabric material. 7. Soil or combination of soil and extruded board insulation to a depth of 4' or equivalent is to be placed over the bed.' 8. The area over the bed is to be finish graded to prevent ponding of surface water runoff. 9. The septic tank and leachfield must not be closerthan 100 feet to any existing private well, 150' to any Class "C"well, or 200 feet to any community well. LEACHFIELD DIMENSIONS TOTAL DEPTH= 8' GRAVEL DEPTH= 6' TRENCH LENGTH= 32' REQUIRES 2" insulation or 2'mounded soil GRC"fER ANCHORAGE AREA BOUGH c�fl� Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME /Q C C MAILING ADDRESS 5Tt4_P,/H-ONE_ $A-aB/3 LOCATION?��/CSG LEGAL DESCRIPTION 10 T/ -Ae'oef1 Gi Z_4fG /e Z'0L4 SEPTIC TANK: DISTANCEL NUMBER OF FROM WELL �6d 'F MANUFACTURER (L u K�OWA) MATERIAL ST G '.. COMPARTMENTS INSIDE LENGTH INSIDE WIDTH. LIQUID DEPTH LIQUID CAPACITY 000 GALLONS. SEEPAGE PIT: � y a� f m NUMBER OF PITS ` DIAMETER _OR WIDTH LENGTHLL, e DEPTH . LINING MATERIAL CRIB SIZE: DIAMETER —DEPTH— DISTANCE FROM: WELL 6 / TOTAL EFFECTIVE BUILDING FOUNDATION22, NEAREST LOT LINE Z6 �. ABSORPTION AREA (WALL AREA) /OZQ SQ. FT. ADDITIONAL ABSORPTION WELL: t TYPE ,r•/�</�/G�� CONSTRUCTION T/09� % DEPTH ZZ DISTANCE FROM: BUILDING NEAREST � -C -L. NEAREST ,N" SEPTIC /6 SEEPAGE �d0 �- FOUNDATION LOT LINEJ12L2_1_. SEWER LINE r� TANK.L—, SYSTEM CESSPOOL OTHERSOURCES APPROVED DISAPPROVED - REMARKS DISTANCES: DIAGRAM OF SYSTEM INSTALLED BY: PIPE MATERIAL: Nr� 2y Ids LOT SLOPE:/ 5�7�'+ [ u!�5 REMARKS:SO/L ADDfl DATE46/15ZZ APPROVED. G.A.A.B. Form No. E"31 ^ SEEPAGE PIT: a a )e a 9 X/O &V inq l8"/ (deo eQ NUMBER OF PITS� .,.ADIIAMETER OR WIDTH -0'Z, LENGTHZ1,� DEPTH,. LINING MATERIAL,�AdIk CRIB SIZE: DIAMETER_DEPTH_DISTANCE FROM: WELL L00 TOTAL EFFECTIVE BUILDING FOUNDATIONNEAREST LOT LINEaA; . ABSORPTION AREA (WALL AREA) /10.10 SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE "411 CO CONSTRUCTION 574A-04'eO • DEPTH I;e DISTANCE FROM: BUILDING NEAREST NEAREST �00f SEPTIC `OO SEEPAGE FOUNDATION LOT LINE - SEWER LINE , TANK SYSTEM IlDO I" CESSPOOL OTHER SOURCES _rep OF WeA1 IASe/p9 Re Se9Lrld APPROVED_' _DISAPPROVED X REMARKSWr-.L 11f/ WET* /09'ee' DISTANCES: INSTALLED BY: S� PIPE MATERIAL: 0417- _De0d, LOT SLOPE: //p g4-5 7- TO p/eSr REMARKS: 50/.1, TCS% aOOp %O 14.0 Form No. E"31 DIAGRAM OF SYSTEM ///V/MeST' 0A,;, 4-' apa(�.G X a DATE *3 �,oa�' aR�AM ter. t�,+K• 1�1 APPROVED G.A.A.B. GRE ER ANCHORAGE AREA BOA D'dGH' a GAflQ Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL'. SYSTEM NAME /r �e" a �% MAILING ADDRESS-TrZe Ir BOK & P/iltts�PHONE LOCATION]&"eST jV1;y, AAA A�5d9e-SIP LEGAL DESCRIPTION �0�% �.� '.I3�OC�E G LAKE KOe SEPTIC TANK: DISTANCE FROM WELL /04P MANUFACTURER � MATERIAL �TcL NUMBER OF COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY_,, OO GALLONS. SEEPAGE PIT: a a )e a 9 X/O &V inq l8"/ (deo eQ NUMBER OF PITS� .,.ADIIAMETER OR WIDTH -0'Z, LENGTHZ1,� DEPTH,. LINING MATERIAL,�AdIk CRIB SIZE: DIAMETER_DEPTH_DISTANCE FROM: WELL L00 TOTAL EFFECTIVE BUILDING FOUNDATIONNEAREST LOT LINEaA; . ABSORPTION AREA (WALL AREA) /10.10 SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE "411 CO CONSTRUCTION 574A-04'eO • DEPTH I;e DISTANCE FROM: BUILDING NEAREST NEAREST �00f SEPTIC `OO SEEPAGE FOUNDATION LOT LINE - SEWER LINE , TANK SYSTEM IlDO I" CESSPOOL OTHER SOURCES _rep OF WeA1 IASe/p9 Re Se9Lrld APPROVED_' _DISAPPROVED X REMARKSWr-.L 11f/ WET* /09'ee' DISTANCES: INSTALLED BY: S� PIPE MATERIAL: 0417- _De0d, LOT SLOPE: //p g4-5 7- TO p/eSr REMARKS: 50/.1, TCS% aOOp %O 14.0 Form No. E"31 DIAGRAM OF SYSTEM ///V/MeST' 0A,;, 4-' apa(�.G X a DATE *3 �,oa�' aR�AM ter. t�,+K• 1�1 APPROVED G.A.A.B. NAME OF APPLICANT INSTALLATION LOCATION GRE"""ER ANCHORAGE AREA BOF JGH' DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO. � 3330 "C" STREET ANCHORAGE, ALASKA 99303 / TELEPHONE 274-4341 /Ce Int Akza is a/c SEWAGE DISPOSAL SYSTEM — APPLICATION AND 'PEMIT C" ` e MAILING ADDRESS C `L J/•R 99e A o 7` LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK • SEEPAGE PIT DRAIN FIELD OTHER J,Q m TYPE AND SIZE OF FACILITY TO BE SERVED 'e"' T C i//0 FINANCED THROUGH ' TO BE INSTALLED BY NOTE1 THIS PERMIT IS NOT VALID WITHOUT SOIL TEST SOIL TEST RESULTSV-"//Djj t H r tIC l 5 O N' Ll COMPLETION DATE ANTICIPATED _it FINAL INSPECTION 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZEyJ 60 TYPE Y/ t/ SEEPAGE AREA SIZE TYPE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT I DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL J / Q / SEPTIC TANK d . SEEPAGE PIT DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK SEEPAGE PIT � ' DRAIN FIELD �UALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK SEEPAGE PIT DRAIN. FIELD I SEPTIC TANK, -/4" /", SEEPAGE PIT �. DRAIN FIELD �—. TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND. INTO CRIB CROSSING GAP OF EXCAVATION S FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. ✓ s / V ; R �,� sCRttwr�6'%A GRAVEL BACKFILL I f/ CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. G�X�Ltu R, S, G.A.A.S. v ^OR LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. 9 DATE V APPLICANT'S SIGNATURE FORM NO. EQ -016 AREA DIAGRAM OF SYSTEM AND THAT THE ABOVE GREATER ANCIIO1',AGE AREA DOROUGA, Department of Environmental Quality 3330 °C" Street Anchorage, Alaska 99503 SOILS LOG - PEROLATION TEST Performed for /lla*_ ,fie ---Date Performed 7/ ->— Legal Uescription: This form reports: Soils log C —�— PercoaT tion tes Depth Feet 2- 3 4 5 6 7- 8 10 _ S/0 .00 11 - 12 - 13 - 14 - Was ground water encountered? ec) If yes, at what depth?' Reading Date Gross Time Net Time Depth to Water Net Drop ET Percolatlon rate nn nun. -Proposed installat of r Seepage Pit Drain Field Depth of Inlet Depth to bottom of pit or trench COMMENTS: Performed EQ -040 (6/74) 0 u Municipality of Anchorage Development Services Department Building Safety Division 'fh�Ili On -Site Water d Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519.6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. DSI ---7, COSH# D 0d t- 3Q 7 1. GENERAL INFORMATION Expiration Date: Z— G Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address LAKERIDGE TERRACE S/D• BLOCK 6 LOT 11 14724 TERRACE LANE • EAGLE RIVER AK • 99577 GILBERTO do SANDRA RAMOS Day phone 696-7180 14724 TERRACE LANE ' EAGLE RIVER AK • 99577 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 Day phone Day phone 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: .Individual Well 0 Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system Is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage (les and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LID. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountored at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory lost results do not guarantee future performance of the system, nor do they guarantee that there are no hidden dofects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for —r bedrooms. Disapproved. Conditional approval for bedrooms, with the fllowing Phone 337-6179 Date li ZLi 10(3 ON-SITE Attachments: ///7Jj� � t))) 1), COSA Checklist Arsenic Advisory Septic System Advisory Maintenance Agreements Well Flow Advisory Supplemental Engineer's Report Nitrate Advisory Other By: Original Certificate Date: 7/03 )R. 11105) Municipality of Anchorage (� Development Services Department Building Safety Division On -Site Water 8 Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: LAKE RIDGE TERRACE- BLOCK 6 LOT 11 Parcel ID: 0 _1- 313 33 A. WELL DATA :PER M.O.A. RECORDS. "112' PER 8/15/1975 INSPECTION Well type PRIVATE If A, B. or C provide PWSID# NIA Well Log (Y/N) NO Date completed 'S 1975 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth *0105 ft. Cased to •40+ ft. Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 11 / 11 /2008 8� Static water level 84 ft Well production N g.p.m. 0.96 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Nitrate 3.73 mg./L. Other bacteria 0 colonies/100 ml. Arsenic: _u gJL. Date of sample:! ! 11 2008 Collected by: GEG Ltd. B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 2/10/2001 Tank size 1250 gal, Number of Compartments 3 Cieanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N)_ N/A Date of pumping 11/11/2008 Pumper JR'S PUMPING C. ABSORPTION FIELD DATA eE ow xISTING GRAD Date installed a/las%,sib = TRENCH Soil rating (g.p.d./ft o a /bd 24s / 21/ System type CRle Length 2e ft. Width 22 ft. Gravel below pipe 6a ft. •9.23/ 252 + 1020 Total depth 10 ft. Eff. absorption area 1272 ft' Monitoring tube YES ' Depression over field NO Date of adequacy test =,/1 /1 1 /2008 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 41 In. Water added 737 gal, New depth69 in. Elapsed Time: 120 min. Final fluid depth 60 in. Absorption rate >= 600+ g.p.d. Any tejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date — **TESTED 1986 TRENCH ONLY. D. LIFT STATION Date installed Size in gallons ManholelAccess (YIN Hi h water alarm level at in. LDattu mp on" level at in�Cycles �Ieve: id Meets alarm & circuit requirements? e E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: E Septic tank/lift station on lot 1 00'+ On adjacent lots 100'+ k Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main N/A Public sewer manhole/cleanout N/A 25'+ Holding tank N/A Sewer /septic service line g Animal containment areas 50'+ Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 51+ Property line 5'+ Absorption field 5'+ 100'+ m Water main N/A Water service line 10'+ Surface water Wells on adjacent lots 1004 SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line +51+ Building foundation 10'+ Water main N/A Water service line 10'+Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONKNOWN Wells on adjacent lots 100'+ k F. COMMENTS x E ♦PFR tgR6 INSPECTION REPORT PREVIOUSLY APPROVED /1 k G. ENGINEER'S CERTIFICATION!• I certify that I have determined through field inspections and 0 * ; ,, „ . ... .......... review of Municipal records that the above systems are in 0 conformance with MOA COSA guidelines in effect on this e °rne. s:' date. Engineer's Printed Name JEFFREY A. GARNESS��Q o• — 5 Ith.. ^ovv Date11'11+ Og edP Ofea alo^°oo ��Onaaoo� COSA Fee $ 2 30 1-1 2S Date of Payment!� 1 11,H U� Receipt Number 2s � (Rev. 11105) r S WaiverFee $ Date of Payment �f �T/L� Receipt Number 3 7a Municipahty of Anchorage VO. Ik,x VXHL;'A) 0 Aochiiragc. Aht%ka, Q.6111 -1i( -A) a 47M I1 r gmv Sir, CI � I lllirc: ISMIi 1:4S:1li:illl • hnx: CNIi 1:i7A841R1 hup://"v�r.numi.ur;; 1Jayor Jfark Begich De-velopmerit Sen -ices Deptirtrticlll November 21, 2008 Gilberto G. and Sandra E. Ramos 14724 Terrace Lane Eagle River, AK 99577-9277 Dear Property Owners: RE: Encroachment: Septic Pipes in Utility Easement Lake Ridge Terrace, Block 6, Lot 11, Grid NNN'0553, 14724 Terrace lane rent q4 . S' i Department The Right of Way Division has reviewed a request for a letter of nonobjection to the existing two septic pipes, which encroach approximately 6' into the 10' Utility Easement at the west property line. On the as -built survey dated February 21, 2001 (Seward & Associates Land Surveying), submitted with the request, the petitioner has shown the encroachments. This letter of nonobjection is issued with stipulations, and by using it the petitioner is agreeing to the following: 1. Municipality of Anchorage (MOA) will be held ham -Jess, now and forever, for any damages or injury to any person as a result of the encroachments. 2. All applicable codes and regulations will be observed and maintained within the easement. 3. This letter of nonobjection will in no way preclude MOA from full use and enjoyment of its rights within any portion of the easement. 4. Additional and extraordinary costs incurred during any future required construction, repair or reconstruction of MOA improvements to accommodate any or all of the encroachments shall be paid by the property owner. 5. Letters of nonobjection from the following utilities are attached: ® Anchorage Water & Wastewater Utility ❑ Alaska Communications Systems ❑ Chugach Electric Association, Inc. ® Matanuska Telephone Association ® Matanuska Electric Association, Inc. ® Enstar Natural Gas Company ❑ Municipal Light & Power ® GCI Cable of Alaska ❑ Eyecom (Girdwood Cable TV) ❑ No letters required All letters of nonobjection should be retained in your permanent files. If you have any questions, please call me at 343-8033. Sincerely, l�Y`� m4'i, /'ily, Jack L. Frost, Jr. Right of Way Supervisor Concur Property Owner(s) Community, Security, Prosperity O:ID"elopneniSeNim!RON '�Non-objeaion lenorVnke Ridge Terence. 81k6. Lm it. Rnmo,.dx Municipality of Anchorage -tel Development Services DepartmentL Building Safety Division , .. , , . On -Site Water 8 Wastewater Program 4700 Bragaw Street 1 P.O. Box 196650 Anchorage, AK 99519-6650 www,muni.org/onsite r (907) 343-7904 ♦F_ f4lioo CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. n 3) 3 — 33 COSA# (0!2039:7 1. GENERAL INFORMATION Expiration Date: 2 , 17— 0 Gi Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address LAKERIDGE TERRACE S/D: BLOCK 6, LOT 11 14724 TERRACE LANE • EAGLE RIVER. AK * 99577 GILBERTO do SANDRA RAMOS Day phone 14724 TERRACE LANE • EAGLE RIVER, AK " 99577 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well 0 Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ Day phone Day phone 696-7180 TYPE OF WASTEWATER DISPOSAL: Individual On-site 0 Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site Ater supply and/or wastewater disposal system Is (are) safe, functional and adequate for the number ofbe&ooms and type of structure indicated herein. I further verify that based on the Information obtained from the Municipality of Anchorage riles and from my Investigation and Inspection, the on-site water supply and/or wastewater disposal system Is(are) in compliance with all applicable Municipal and SUMe codes, ordinances, and regulations in effect at the time of installation. : 1, Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 Engineers Printed Name JEFFREY A. GARNESS, P.E. Date 11 I o 6 Engineer's Comments: In conducting this evaluation, GEG, VD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines d Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily Identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party Is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for bedrooms. Disapproved. / Conditional approval for bedrooms, with the fllowing stipulations: Attachments: COSA Checklist Arsenic Advisory Septic System Advisory Well Flow Advisory Nitrate Advisory ✓ Maintenance Agreements Supplemental Engineer's Report Other By: 1 Original Certificate Date: (Rw. 11105( / r-\ Municipality of Anchorage C• --1 Development Services Department Building Safety Division On -Site Water 8 Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519.6650 www.muni.org/onsite (907)343.7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST - t Legal Description: LAKE RIDGE TERRACE; BLOCK 6, LOT 11 Parcel ID: 09—/ - 313 - 33 A. WELL DATA ,;112 RECORDS. ER 8/ 5/1975 INSPECTION Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (YIN) NO Date completed '5/1975 Sanitary seal (YIN) YES Wires properly protected (YIN) YES Total depth "105 ft. Cased to `40+ ft. Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 11/11/2008 Static water level PJPft. 84 ft. O Well production N g.p.m. 0.96 g,p,m, WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi. Nitrate 3.73 mg./L. Other bacteria 0 colonies/100 ml. Arsenic: ug./L. Date of sample:l 1/11/200 Collected by: GEG Ltd. B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 2/10/2001 Tank size 1250 gal. Number of Compartments E Cleanouts (YIN) YES Foundation cleanout (YIN) YES Depression over tank (YIN) NO High water alar (YIN) N/A Date of pumping 11/11/2008 Pumper JR'S PUMPING C. ABSORPTION FIELD DATA I -BELOW EXISTING GRADE 6/8/1986 TRENCH Date installed 6/15/1975 Soil rating (g.p.d./ft'o /bd 245 System type CRIB 21/ 3/ 6/ Length 29 ft. Width 22 ft. Gravel below pipe 4 ft. 09.25/ 1252 + 1020 Total depth 10 ft. Eff. absorption area 1272 ft' Monitoring tube YES Depression over field NO Date of adequacy test '• 11/11/200 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test' 41 in. Water added 737 gal. New depth 69 in. Elapsed Time: 1120 min. Final fluid depth60 in. Absorption rate >= 600+ g.p,d, Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date **TESTED 1986 TRENCH ONLY. D. LIFT STATION Date Installed Size in gallons Manhole/Access (YIN) "Pump on" level at in. 'Pump oft" leve High water alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent 1 Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main N/A Sewer /septic service fine 25'+ Animal containment areas 50'+ Public sewer manhole/cleanout N/A Holding tank N/A Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field Water main Wells on adjacent lots 100'+ Water service line 10'+ Surface water 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 'S'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and p` ! `� - Yn review of Municipal records that the above systems are In 0"""" " ' " """ " conformance with MOA COSA guidelines in effect on this date. J e orne s. Engineer's Printed Name JEFFREY A. GARNESS Q o� •. I 5 �FO� Date it )14 1013 �� 1e0'' fl L \Low PForesslo� 4� ��400oo�c COSA Fee $ L1 30 A- 1-7 S Date of Payment Receipt Number. (Rev. 11105) Watver-Fee $ /1 Date of Payment Receipt Number Municipality of Anchorage e e •� Development Services Department Building Safety Division „ --� On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Nater Well Advisory Health Authority Approval # 080397 During a recent Health Authority Approval on-site inspection and test of the potable water supply well on Block 6, Lot 11 of Lake Ridge Terrace subdivision, the well's productivity was determined to be 0.96 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 4 -bedroom residence is 0.41 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Health Authority Approval. May 25 04 11i0la Eva Laken 907 609 6476 v P.1 ASBUIL7 SMIARD 6 ASSOCIATEStLBND bUKVr XiftU b R�UVL`f I HEREBY CERTIFY -THAT I HAVE SURVEYED THE..SOF At ' ( FOLLOWING DESCRIBED PROPERTYr r • .fsi�/C�fffPT DATE r r V- ''�9�,.t �. AND THAT NO ENCR=HMENTS ?7 IST EXCEAS T M { INOICATED. IT IS THE RESPONSIBILITY -OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY GRID, i EASEMENTS, COVENANTS OR RESTRICTIONS iYu/�•f•� ��* �� ai WHICH DO NOT APPEAR ON THE RECORDED SUBDI• 1 s •. vISfON PLAT. UNDER Nor SHOUT FB' 4•• Ls 6918 ' ANY DATA HEREON BE USED FOR CONSTRUCTION �� �S �+� r 0= TAE FENCE LINES, OR FOR ESLISHING BOUND- pgAWNr ARY LINES. Q�C171� tTc(rZo Municipality of Anchorage • ^� Development Services Department •`' / Building Safety Division On -Site Water and Wastewater Program •• ••• 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Recerti-Ptce Lo►) Parcel I.D. 051-31333 HAA #_ O 4 O / Expiration Date: 3 — / - O -6- 1. GENERAL INFORMATION Complete legal description Lot 11 Block 6 Lake Ridge Terrace Location (site address or directions) 14724 Terrace Lane, Eagle River. AK 99577 Current Property owner(s) Prudential Relocation Day phone Mailing address 14724 Terrace Lane, Eagle River AK 99577 Lending agency Day phone Mailing address Real Estate Agent Barbara Crittenden/Prudential Vista Day phone 689.6464 Mailing Address 16635 Centerfield Drive Eagle River AK 99577 Unless otherwise requested, HAA will be held by DHHS for pickup. NAA picked up by: 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well - Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site 19 Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given In paragraph 5 by an Independent professional civil engineer registered In the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) on properties served by a single family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to home owners. Certificates of Health Authority Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. (P�. t lm) 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown foo , I verify that Authority App oval stigation based on procedures outlined in the Health Authority App roval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. 1 further verify that based on the Information obtained from the Municipality of Anchorage files and from my Investigation and Inspection, the on- site water supply and/or wastewater disposal system Is in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Pannone Eng. Svc. Phone - 272-8218 Address P.O. Boz 102954 Anch AK 99510 Date Engineer's Printed Name Steven R. Pannone P.E. Engineers Comments: In conducting an adequacy test, I attempt to provide a thorough, conscientious 'o�OF ,1,- engineering analysis of the system in ac with MOA DSD Guidelines & Regulations. The ♦ P� � „ reported results describe the performance of the system under the conditions encountered at the time of �� ` , the test, and separation distances measured to readily identifiable features. The operational life of all ; wells and septic systems depend on the local soil condition, ground water levels that may fluctuate �! {x F• 49TH during the year, and the water usage of the family being served by the system These conditions are jo,,, : ,,, .........«....... outside the control of the evaluator of this system All systems eventually �at therail ande ate n hidden defects ... ............... tisfactory test results 001 do not guarantee future performance of the system, nor do they guaranteeSteven R. Ponnon, or encroachments. PES can therefore not provide any Warrarmry for future performance nor give any estimate of how long the system will continue to meet the operational requirements of the ADEC or i '% No. CE 8149.e, MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon ••.... d t�C.° or use of this report by any other person or parry is not authorized nor will it confer any legal right t#44 #4 t( whatsoever. �,hl•?.� 6. DSD SIGNATURE </Approveci for _LL bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: M, Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By Expiration Date: (Pe . tvae) Original Certificate Date: 1 2 L!: O Reissue Date: Municipality of Anchorage e • Development Services Department Building Safety Division On -Site Water and Wastewater Program + 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.enchorage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 11 Block 6 Lake Ridge Terrace Parcel I.D.: 051-31333 A WELL DATA Well type P If A, B, or C provide PWSID # Date completed X1415 Sanitary seal ygg Total depth 10S ft Cased to _49 -+_ft FROM WELL LOG Date of test Static water level Not 6,vallable ft Well production g.p.m Well Log N Wires properly protected ygg Casing height (above ground) 20 In. AT INSPECTION 91912004 82 ft 1.5 9 -p.m WATER SAMPLE RESULTS: 51.31,260y Coliform "6�/ colonies/100 ml Nitrate 4,04 mgll Other bacteria `-8— colonies/100 ml Ne -Lb zrc"`t P( Date of sample: 919/2004 Collected by: Laura Pannone B. SEPTIC/HOLDING TANK DATA Tank Type/Material Anchorage Tank Steel Date installed 2110/2001 Tank size 1250 gal Number of Compartments $ Cleanouts Y Foundation cleanout Y Depression over tank y High water alarm N _ Date of pumping 1112612003 Pumper JR's Pumping C. ABSORPTION FIELD DATA See 5(204-t OY) Date installed $1151197 Soil rating (g.p.d./ft2 or ft2/bdrm) 4 System type Crib/Trench IKslcn &1S/8 5 Length X28 ft Width ft Gravel below pipe ft Total depth 11.5 ft Effective absorption area JMfe Monitoring tube x Depression over field 7rehct', %C'-to?,Z. TreAa,.,.;z52 Date of adequacy test 5/3/2004 Results (Pass/Fail) Pass* r For 4 bedrooms Fluid depth in absorption field bef . test 77 in Water addedM gal. New depthZ2 in. I re#1411 T5- $ 7-re,1Ct. s& ,5 Elapsed Time:1440 min Fir1@I fluid dept L in Absorption rate >= 600+ g.p.d. I Nail CJA 5-5 Any rejuvenation treatment (past 12 mo.) (Y/N& type) N If yes, give date (Rev. 11199) D. LIFT STATION Date installed Size in allns 'Pump on" level at _ in`Pump ofP IdveT f, _ in Datum E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 105.5 Absorption field on lot 100.2 Public sewer main NIA Sewer /septic service line _29'+ Manhote/Access High water alarm level at _ In Meets alarm & circuit requirements? On adjacent lots 100+ On adjacent tots 100+ Public sewer manhole/cleanout NIA Holding tank 190+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 25'+ Absorption field 1g'+ Water main 50'+ Water service line _20'+ Surface water 100+ Drainage 100+ Welts on adjacent lots 100+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: - Property line ' Uhl Building foundation J5'+ _ Water main 50'+ Water Service line 20'+ Surface water 100+ Driveway. parking/vehicle storage So'+ Curtain drain None Observed Wells on adjacent lots 100_ F. COMMENTS G. ENGINEER'S CERTIFICATION : fid' `9 ' 1 certify that I have determined through fleld inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. ............... e�en . none? Steve i o Pannone. P.E. 1��j ., � CE Brag Engineer's Printed Name q (U,..•'�.� Date ,'t.0i 40 HAA Fee $ N 3 Date of Payment 524 / Gq Receipt Number 5 ?' (Rev. 11199) Waiver Fee $ Date of Payment Receipt Number ap Municipality of Anchorage .� Development Services Department Building Safety Division On -Site .. �., Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FORA SINGLE FAMILY DWELLING c/ Parceli.D. 051-313-33 HAA# C-)qZ� 2S 0 it Expiration Date: — D 3 1. GENERAL INFORMATION Complete legal description Lot 11 Block 6 Lake Ridge Terrace Location (site address or directions) 14724 Terrace Lane Eagle River AK 99577 Current Property owner(s) Anthony Grootens I Day phone 622-0200 Mailing address 14724 Terrace Lane Eagle River AK 99577 Lending agency Day phone Mailing address Real Estate Agent Eva Loken 0 Prudential Vista Day phone 689-6476 Mailing Address 16635 Centerfield Drive Eagle River AK 99577 Unless otherwise requested, HAA will be held by DHHS for pickup. HAA picked up by: 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) on properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to home owners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. (Rm »W) S. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation based on procedures outlined in the Health Authority Approval Guidelines for this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system Is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on- site water supply and/or wastewater disposal system is in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of Installation. Name of Firm Pannone Eng. Svc. Phone 272-8218 Address P.O. Box 102954 Anch AK 99510 Engineer's Printed Name Steven R. Pannone P.E. Date Engineers Comments: In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MOA DSD Guidelines & Regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are AV OF outside the control of the evaluator of this system All systems eventually fail and satisfactory test results 0' do not guarantee future performance of the system, nor do they guarantee that there are no hidden defect,/.,, or encroachments. PES can therefore not provide any warranty for future performance nor give any estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon 1 or use of this report by any other person or party is not authorized nor will it confer any legal right whatsoever. 6. DSD SIGNATURE 49TH ..r ... .......... ;Steven �nnone: No. CE 8149 Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments Attachments: ON-SITE •• c� � m . PROGRAM HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By: Original Certificate Date: �o Expiration Date: Reissue Date: )Rev. 11199) ■°ate 1 9.ti_ .� - J��te -'#.. _ .._, 4L Aix Municipality of Anchorage11"1 • '� Development Services Department Building Safety Division " On -Site Water and Wastewater Program 6 " a * r 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 11 Block 6 Lake Ridge Terrace Parcel I.D.: 051313-333 A. WELL DATA vo Well type P if A, 8, or C provide PWSID #,__ Well Log P , I, Ves Lkd' Datecompleted..A-155 Sanitary seal V_�Ie& Wires properly protected Total depth _10—ft Cased to -Aft—ft Casing height (above ground) 20 In. FROM WELL LOG AT INSPECTION. Date of test it ` $13/2004 Static water level of Available ft 81 ft Well production 9 -p -m 1.57 9 -p.m WATER SAMPLE RESULTS: Coliform „R _colonles/100 ml Nitrate :4.64 mgn Other bacteria 0 colonies/100 ml Date of sample: 5!312004 Collected by: Laura Pannone B. SEPTIC/HOLDING TANK DATA Tank Type/Material Anchorage Tank Steel Date installed 2/10/2007 Tank size 1250 gal Number of Compartments I Cleanouts Y Foundation cleanout Y Depression over tank N_ High water alarm NIA Date of pumping 11/26/2003 Pumper JR's Pumping C. ABSORPTION FIELD DATA Date _iinstal�8/1 IS 9775 Soil rating (g.p.d.e or ft%drm)" System type Cribrrrench Length 29 Width 22 ft Gravel below pipe 4 It Total depth Effective absorptiion area 02 fe Monitoring tube Y,I y Depression over field yL�fN• �( ii+rr � Z ,^ate^ S¢e SC%-I'ron F: Cc, Ale *$ TyyTT Date of adequacy test 1312004 Results (Pass/Fail) ss" For 4 bedrooms oLt Fluid depth in absorption field before test Z in Water added60 gal. New depthL in. .b. 01 1-1-anc1 Tmh-ck .5G,5 Elapsed Time: 1440 min Final fluid dept 77 in Absorption rate >= 600+ g.p.d. "_Vx�K 65 Any rejuvenation treatment (past 12 mo.) (YIN & type) N If yes, give date .(Rev. WWI 16� D. LIFT STATION Date installed _ "Pump on" level at /)� _ s s -464'9fzYtAn gall o/► Manhole/Access ofP' level �tL in High water alarm level at _ in Cycles tested Meets alarm & circuit requirements? _ E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 105.5 On adjacent lots 100+ Absorption field on lot 100.2 On adjacent lots 100+ Public sewer main NIA Public sewer manhole/cleanout N/A Sewer /septic service line 25'+ Holding tank 100+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation _5'+ Property line 251+ Absorption field 15'+ Water main 50'+ Water service line 20'+ Surface water 100+ Drainage 100+ Wells on adjacent lots 100+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 5' tA)D t �� Building foundation 151+ Water main : 50'+ Water Service line 20'+ Surface water 100+ Driveway, parking/vehicle storage 50'+ Curtain drain None Observed Wells on adjacent lots 100+ F. COMMENTS G. ENGINEER'S CERTIFICATION W' "♦♦ I certify that t have determined through field Inspections and i ,r H '� ♦♦j ..... ........... review of Municipal records that the above systems are in 00 .........i. ♦ conformance with MOA HAA guidelines in effect on this date.% ��'.Steven R. •Pannone Y7 Engineer's Printed Name Steven R. Pannone. P.E. ♦i� '•. No. CE 51 49 Date ♦ • •••.............!• • HAA Fee $ o Waiver Fee $ t Date of Payment O / Date of Payment Receipt Number �� TJ / Receipt Number (Rev. 11/99) May 2504 l l i Ol a Eva Laken 907 669 6476 P.1 2s�a' ASSUILT SEWARD 6 ASSOCIATES LAND SURVEYING 694-O829 I HEREBY CERTIFY THAT I HAVE SURVEYED THE SCALE'',_,, �F *` f FOLLOWING DESCRIBED PROPERTY, go, Q Cq «LF�YirGG�ETE�P.erfGr�tmT/Cel '..DATE, AND THAT NO ENCROACHMENTS iiIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE Z 2/ i �; TM �V g OWNER TO DETERMINE THE EXISTENCE OF ANY BRID, °"" •• d EASEMENTS. COVENANTS, OR RESTRICTIONS it/W6.r� .7.'r-4 . ;4�aaq WHICH DO NOT APPEAR ON THE RECORDER SUSDI- o,,..,. *..k s.w..a +' a �/ VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD FS` L5-6918 =`f ANY DATA HEREON BE USED FOR CONSTRUCTION OF FENCE LINES, OR FOR ESTABLISHING BOUND -DRAWN, ARY LINES. cipali'y of Anchorage` .: Complete legal description LAKE=RIDGE =TERRACE=SUBDIVISION: LOT 11; BLOCK• 6. Location (site address or directions) 14724=TERRACE LANE • EAGLE RIVER AKT-99577 Cunent Property owners) ROGER ,THOMPSON" Day phone 696-051 t3' 71 Mailing address` . 14724 =TERRACE LANE '*EAGLE RIVER, AK 99577 Lending egenq Day phone Mailing address , Estate Real Estate Agent , - EVA . LGKEN w/ PRUDENTWL VISTA Day phone 689-6464 Mailing address 16635 ' CENTERFIELD DRIVE • EAGLE -'RIVER, AK, 99577 Unless otherwise requested, HAA wAl behold by DSD for plokup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of tills (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineers work. Note: Alaska Water and Wastewater Consultants, Inc. shall be paid $1,770.00 at, or prior to closing for the engineering services provided. Doc, 4. STATEMENT OF INSPECTION BY ENGINEER Ci As certified by my seal affixed hereto and as of the val/dationdeto shown below, l verify that my Investigation, based on procedures outlined In the Health AuthodtyAppmval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. l further verify that based on the Information obtained from the Municipality of Anchorage files and from my Investigation and inspection, the on-site water supply and/or wastewater disposal system Is(em) In compliance with all applicable Munidpal and State codes, ordinances, and regulations In effect at the time of installation. Name of Firm - ALASKA WATER & WASTEWATER CONSULTANTS, INC. Phone 337-6179 Address, ,6901 DEBARR ROAD, SUITE 2B • ANCHORAGE, 'AK 99504 Engineer's Printed Name JEFFREY A. `GARNESS, P.E. Date tngmeers comments: in conducting this evaluation, AMNYC, Inc. attempted to provide a Morough, conscientious engineering analysts of the system In accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results descrtbed the performance of the system under the conditions encountered at the time of the test, and separation distances measured to madity identifiable features. The operational file of aff wells and septic systems depend on the local soils condition, groundwater kwis that may fluctuate during the year, and the water usage of the family being served by Me system. These conditions are outside the conird of the evaluator of tie system. Satsfactory test results do not guarantee future performance of the system, nor do tieyguarantee that there are no hidden defects or encroadnents. AWWC, Inc. can Merefore not provIde any wenanty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. Tire content of this report is for Me sole benefit of the owner Ilsted above. Anyreliahce upon cruse of this report by any oMer person orpartyis not authorized, nor will t conferany legal right whatsoever. 5. DSD SIGNATURE _,e!�_ Approved for _-4— bedrooms. Disapproved. Conditional approval for bedrooms, with the fllowing stipulations: C Note: The well for this property meets existing State and Munic fo �q°PPON, *rC'. c'so ON-SITE WATER AND tTt' WASTEWATER PROGRAM z INN .oaJV-bm.3'eTSEV��ks' There are nitrates present. It is suggested that periodic testing be performed to insure the wells continued suitability. Current nitrate concentration is5.96 mg/1. EPA maximum concentration is 10.0 m¢/l. More info on nitrates is available from On -Site Services,CPD,343-4744 Attachments: HAA Checklist Manitenance Agreements Septic System Advisory Supplemental Engineer's Roort Well Flow Advisory Other /i�% �'ra-�G A "t/.h 5"/— By: _ i (i Original Certificate Date: FW. +swoh Municipality of Anchorage � ; 4 Development Services Department Budding Safety Division On-Sfte Water 8 Wastewater Program 4700 South Bregaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchomge.ak.us (907)343-7904 HEALTHAUTHORITY APPROVAL CHECKLIST F Legal Description: LAKERIDGE TERRACE SUBDIVISION; LOT 11, BLOCK 6 Parcel ID: 051-313-33 *PER M.O.A. RECORDS A. WELL DATA **112' PER 8/15/1975 INSPECTION REPORT Well type PRNArE If A B, or C provide PWSID# N A Well Log (Y/N) NO Data completed *5/1975 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth ** 105 ft. Cased to '40+ A. Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION 3 Date of test 11/3/2000 3 v Static water level �� ft. e0 fL a Well production g.p.m. 1.95 g.p.m. WATER SAMPLE RESULTS: t Coliform colonies/100 ml. Nitrate 5 mgA. Other bacteria colonies/100 mL Date of sample: 2/12/2001 Collected by: AWWC,' INC. i B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEEL Data Installed 2/10/2001 d k Tank size 1250 gal. Number of Compartments E Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (YM) NO High water alarm (YM) N/A Date of pumping NEW Pumper ? C. ABSORPTION FIELD DATA IOTEST PERFORMED ON rn NCH ONLY Date installed s 151 1975 Soil rating (g.p.dJfVo /bd 245 System type FRENCH/CRIB t Length 21'/29' ft. Width 3'/22' ft Gravel below pipe Total depth —V-10' ft. Eff. absorption area Zoz6 fe Monitoring tube YES Depression over field NO Date of adequacy test 11/7/2000 Results (Pass/Fail) PASS For *4 bedrooms i. ' Fluid depth In absorption field before test 9.5 in. Water added 1036 gal. New depth s6 in. ' Elapsed Time: 830 min. Final fluid depth 46_75In. Absorption tate >= 600+ g,p.d, s a Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date — Date "Pump on" level at n. "Pump oft" l- -�In. High water alarm level at in. Dam Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ Public sewer main N/A On adjacent lots 100'+ Public sewer manholetcleanout N/A Sewer /septic service line 25'+ Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water, 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: *PER 7/22/1986 INSPECTION REPORT Property line *5'+ Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 50'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through Field Inspections and review of Municipal records that the above systems are In 0 ........ ' • • ' • •' • ` .... conformance with MOA HAA guidelines In effect on this date. fr s Engineer's Printed Name JEFFREY A. GARNESS o��09�' E 53 Date oZ — I to -1n>1 �0`*� '' • .... o��,o HAA Fee $ Waiver Fee $ Date of Payment Receipt Number. (Rev. 12fOO) Date of Payment Receipt Number MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date t. GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Lot 11 Block 6 Lake Ridge Terrace T15N R2W Sec. 25 Location (address or directions) Hillcrest Rd.. (b) Applicant NameDave Berry Telephone: Home 688-3443 Business 264-6627 Applicant Address' 1710 Blue Spruce Lane Eagle River AK 99577 (c) Applicant is (check one): Lending Institution ❑ ; Owner/builder Q; Buyer ❑ ; Other ❑ (explain); (d) Lending Institution City Mortgage Telephone 694-3503 Address Centerfield Drive Eagle River AK 99577 (e) Real Estate Company and Agent Address _ Telephone (f) Mail the HAA to the following address: pickup by applicant 2. TYPE OF RESIDENCE Single-family [C Multi -Family ❑ Other Number of Bedrooms 43 3. WATER SUPPLY Individual Well R) Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite ID Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 72-025 0+/84) Page 1 of 2 f'*,N em 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION Aq certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Telephone Address EAGLE RIVER ENGINEERING SERVICES Date s���/&6 EAGLE RIVER, AK 99577 694-5195 4 ` hdlh*r's Seal is ",�"�� i;��# °• fa u) ...n.......... Louis A. autero CE -6736 6. DHEP APPROVAL Ap roved for 3 be by Date Approved X Disapproved Conditional Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (11/84) MUNICIPALITY OF ANCHORAGE (MOA) aFDrvryOF Op HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 Mgr2� 0�6 284-4720 2 Legal Description: �cf 11 ATI -'r4 *e - Legal 86' JQa(�t %rr'oc¢ rl5 N 2z w Sec 2r A. WELL DATA ` ,{re,O Well Classification �2 ! ✓A T r If A, B, C, D.E.C. Approved (Y/N) N�4 Well Log Present (Y/N) Ze!4 a ate Completed y •/5 JS' Yield Total Depth t / �� + Cased to �L/o Depth of Grouting IV .4 ✓�+�"/Y Static Water Level SIS / Pump Set At ! y Casing Height Above Ground o2 Sanitary Seal on Casing (Y/N) Electrical Wiring in Conduit (Y/N) % Depression Around Wellhead (Y/N) N Separation Distances from Well: To Septic/Holding Tank on Lot /ov ; On Adjoining Lots rr"' � To Nearest Edge of Absorption Field on Lot �G` ; On Adjoining Lots moi° o To Nearest Public Sewer Line To Nearest Public Sewer Cleanout/Manhole To Nearest Sewer Service Line on Lot Water Sample Collected by E.Jlc je" '^ r "'s �• : Date y'43 .0Z" Water Sample Test Results Comments /vc// 02+c .rxr 2 rid °Vn +s fJk c cared J+ `40 B. SEPTIC/HOLDING TANK DATA Date Installed /'.7S Size No. of Compartments Standpipes (Y/N) y — Air -tight Caps (Y/N) y Foundation Cleanout (Y/N) Depression over Tank (Y/N) /V Date Last Pumped 6 Pumping/Maintenance Contract on File (Y/N) N11'f ; for Holding Tank High -Water Alarm (Y/N) i✓Ih Temporary Holding Tank Permit (Y/N) Separation Distances from Septic/Holding Tank: To Water -Supply Well / To Building Foundation lcJ ! To Property Line r/o To Disposal Field /O To Water Main/Service Line �/" To Stream, Pond, Lake, or Major Drainage Course Al /A Comments page 1of2 C. ABSORPTION FIELD DATA 0 Soils Rating in Absorption Strata X700 �R2 Type of System Design ff- ase -,e2 Date Installed 6 7 Length of Field a -Z Width of Field ?4 _ Depth of Field Gravel Bed Thickness 6 Square Feet of Absorption Area /C -Z Standpipes Present (Y/N) Y Depression over Field (Y/N) N Date of Last Adgquacy Test -S gd Results of Last Adequacy Test S4 A,;+e. Separation Distance from Absorption Field: To Water -Supply Well /OO To Property Line oZ U To Building Foundation To Existing or Abandoned System on Lot N/Q ; On Adjoining Lots ?a To Water Main/Service Line 1,/0 To Cutbank (if present) ^!�/4 To Stream/Pond/Lake/or Major Drainage Course w14 To Driveway, Parking Area, or Vehicle Storage Area t/U Comments D. LIFT STATION A/, Date Installed Size in Gallons "Pump On" Level at _ High Water Alarm Level at Tested for Electrical Codes (Y/N) _ Comments Dimensions Manhole/Access (Y/N) — "Pump Off” Level at T Vent(Y/N) Pumping Cycles during Adequacy Test. Meets MOA Check Permitted Bedroom Rating Against HAA Request" I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed Date 4-/z _ Company MOA No. Receipt No. p w, Date of Payment iP2 , ✓ 9^ Amount: $ 6 C)„_ rtgineer's Seal Page 2 of 2 72-028 111/84) lours A. Butera CE -6736 pROFE55`�-J .- MUNICIPALITY OF ANCHORAGE DIVISION OF ENVIRONMENTAL HEALTH DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE 1. General Information Application Date71'.�-M Ice', _3 (a) Legal Description (include lot, block, subdivision, section, township, range) _1�T 1 t OK to Lara 2-1066 1—C 12 enc t Location (address or directions) 1-7/0 6L(4F S2&LtC67 1.AnIL= (b) Applicants ne - Applicants Address /-7 /V $lur 5g2u cc- C -N,%, a-ugc z A -r gGs77 (c) Applicant is (check one) Lending Institution Buyer E::l ; Other [=I (explain); OwnerAttilder ry%:-T ; (d) Lending Institution '94,jk Telephone Ai&- 7ZO6 Address Ppy.c11 7012 AKe.4acA.66 /4k 49S -1U (e) Real Estate Co. 6 Agent Address Telephone (f) Mail the HAA to the following address: 2. Type of Residence Single -Family Multi -Family Q Number of Bedrooms 3 3. Water Supply Individual Well M Community = Other (describe) Public M Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. Sewage Disposal Onsite VK: Public Q Community Q Holding Tank M Note: If community well system, must have written confirmation from the State L Department of Environmental Conservation attesting to the legality and status. [Page 1 of 2] r Lvf 5. Engineering Firm Providing Inspections, Tests, File Search, Data and Information As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that, based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regula- tions in affect on the date of this inspection. Name of Firm A 6C S Telephone 5'0-70 10 Addres (ENGINEER SEAL) 6. DHEP Approval Approved for bedrooms Byl Approved >- Disapproved Terms of Conditional Approval CAUTION Conditional' THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ,ENVIRONMENTAL PROTECTION (DREP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT- ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE- NENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK. (DHEP SEAL) RR4/ej/D18 [Page 2 of 2[ 7-19-84 C. Reid, Jr. 2251-E Conditional' THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ,ENVIRONMENTAL PROTECTION (DREP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT- ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE- NENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN THE PROFESSIONAL ENGINEER'S WORK. (DHEP SEAL) RR4/ej/D18 [Page 2 of 2[ 7-19-84 MUNICIPALITY OF ANCHORAGE (MOA) IEALXH AITIHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 a3A13D3N boa £ 030 N011031OU 1V1N3WNOMIAN3 7 H11V3H 40 '1d30 ROV"WH7NV 40 A111VdQ1NnN A. MLL DATA Legal Description: fht l 'RIO laKe�Q" well Classification 171V✓44- If A, B, cc C D.E.C. Approved(Y ) Well Log Present (Y' Date Complete y Yield Total Depth -/�-1 / I9 _I steed to %4/0 � Depth Geouti 0n / Static Water Level 49L.4p719 Pump Set At LIrY)��J�xyc . Casing Height Above Ground ,1��� Sanitary Seal on Casing Electrical Wiring in Conduit ) Depression Around Wellhead (iAA Separation Distances from We To Septic/Holding Tank on Lot boil Cn Adjoining Lots 4-100 To Nearest Edge of Absorption Field on Lot tCD *- ; On Adjoining Lots X100"t To Nearest Public Sewer Line Azh To Nearest Public Sewer Cleancut/Kanhole To Nearest Sewer Service Line on LotA Water Sample Collected By f Date water Sample Test ResultsSF Com�ents nue -2j ciu� a 0 -,�-A . frft __. IL. B. SEPTIC/HOLDING TANK DATA' Date Installed v Size 'J&rb No. of Ca:giartmsnts Standpipes Y ) Air -tight Caps (YA) Foundati Cleanout (Y Depression over Tank (Y ) Date Last Pumped q)act Pumping/Maintenance Contract on File (YIN) ; for Holding Tank High -Water Alarm (Y/N) Temporary Holding, Tank Permit (YIN) Separation Distances frcn Septic/Holding Tank: To Water -Supply Niall IUI/ � To Building Foundation H/ To Property Line tk&'JC— To Disposal Field 31,# To Water Main/Service Line t- 1t ' To Stream, Pond, Lake, or Major Drainage Course Ccmnents Go -- (Page., 1 sof 21_ 4 ot> �a13t$ 2-15+84 k l l C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata �IEY� Type of System Design ",t,& Date InstalledSl�lSI ,�S Length of Field Lq / Width of Field aid Depth of Field 12.51 Gravel Bed Thickness /o/ Square Feet of Absorption Area iD2j'5Standpipes Present i*DN) Depression over Field (Y Date of Last Adequacy Test 11hajt4 Results of Last Adequacy 'asst Saii P'A -fin _ ya 6, 20100 Separation Distance fran Absorption Field: To Water -Supply Well 1 l O ' dF To Property Line .Hap To Building Foundation f4 ;L' To Existing cr Abandoned System cn Lot : On Adjoining Lots _ Zp� To Water Main/Service Line } 94 :K- To Cutbank(if present) IJIA- To Stream/Pond/Lake/or Major Drainage Course-r-yaol To Driveway, Parking Area# or + VehicleStorage Area `A,,& CCMTents .' VYtQ" AV w oAA k rf.,,. 1 O uW n n . �,o,� A ,. D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at " u Off" Level at High Water Alarm Level at Vent (YIN) Tested for Pumping Cycles dueing Adequacy Mast. Meets MOA Electrical Codes(Y Comments . ** Check Permitted Bedroan Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MSA HAA "lines. in effect on the date of is i coon. Signed Date c C Company Pvc, C MOA No. -D2t�� � ti e; a% KBl/d5/s ;. C. rpt t 1 (Page 2 of 21 t° 2-15-84 111 P"41� r' ALASKA E110011Ii1E(1TAL C011TROL SERUM, Inc. Enqineerinq 5 Enuironmental Studies NOVEMBER 29 1984 DAVID BERRY 1710 BLUESPRUCE LANE EAGLE RIVER AK 99577 SELLER — DAVID BERRY BUYER — SUBDIVISION — LAKERIDGE TERRACE BLOCK — 6 LOT — 11 ADEQUACY TEST FOR SEWER SYSTEM THE TYPE OF ABSORPTION SYSTEM IS A CRIB WITH AN AREA OF 1020 SQFT. THE SYSTEM IS CAPABLE OF ACCEPTING 450 GALLONS OF WATER PER DAY. THE SURGE CAPACITY OF THE SYSTEM IS 284 GALLONS. BASED UPON THE TEST DATA THE SYSTEM IS ACCEPTABLE FOR A 3 BEDROOM HOME. THE SEPTIC TANK WAS PUMPED ON SEPT 29 1984 . A FLOW TEST WAS PREFORMED ON THE WELL. 284 GALLONS OF WATER WAS PUMPED AT A RATE OF 2.6 GPM OVER A DURATION OF 3 HOURS. THE DRAWDOWN WAS 23.25' WITH A RECOVERY TIME OF 60 MINUTES AND THE STATIC WATER LEVEL WAS 77.51 FEET. THE WELL IS ADEQUATE FOR THIS 3 BEDROOM ROME. SEPTIC TANK ADEQUACY THE EXISTING SEPTIC TANK VOLUME OF 1000 IS ADEQUATE FOR THIS 3 BEDROOM HOUSE. 1200 Test 33rd Auenue, Suite E • Anchorage, Alaska 99503 • (901) 561-5040 11/24/84 Dear Mr. Barry, Our son called us from Alaska and said you needed information regarding your well. Hopefully the following statement will fill your needs on Lot 119 Block 6, Lakeridge Terrace Subdivision. As you know, ,the house was built in 1975. We drilled the well ourselves in late May, 1975. To the best of my recollection the well was drilled to 128 feet and was cased all or nearly all the way. I have no doubt that the well casing exceeds 40 feet in depth, sincewe always put the casing all the way down. We would be happy to give you further information, but If we still have a copy of it, it would be stored in our files in Alaska, and our son Dean says he hasn't found anything, Hope this helps. If you need anything else let us know. Sincerely, a MUNICIPALITY OF ANCHORAG;+'S DEPARTMt, OF HEALTH AND ENVIRONMEN _L PROTECTION 825 LStreet, Anchorage, Alaska 99501 � /�,27�1, ext. 224 or 225 C`y Date Received: May 26, 1977 #1: Time 2:3 m. #2: Time i"V)(ifft #3: Time /'QQerA Date 5-27 7 Firday Date /(11, 1 L . Date /. Insp KenLe�y Insp nfZOA Insp clxc6ll REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES } 1. Lending Institution Request: Alaska National Bank of the North Mailing Address: Pouch 7-010 Calais II Phone: 278-4581 2. Property Owner: Kathy Swires Phone: 688-3343 Mailing Address: ! 3. Legal Description: Lot 11 Block 6 Lake Ridge Terrace Subdivision +L 4: Single Family Residence: (:) Number of Bedrooms: three Multiple Family Residence: '( ) Number of Bedrooms: 5. Well Systeme Individual Well (x) Community/Public System ( ) 4 t Permit # Depth of Well Well Log on File ( ) Construction Bacterial Analysis 6. Sewage Disposal System: On-site System (x)x Public Utility ( ) ! Permit # Installed Installer: «, Q Z a r Septic Tank Size 4nm Manufacturer f �- Absorption Area .Soils Rate Material 7. Distances: Well to Septic Tank r to Absorption Area to Sewer Line Nearest Lot line Absorption Area }' to Nearest Lot Line r: 'k 1 y 7 ? IAUelPALITi OF ANCHORAGE ` 1 !.'. .. DEPT. OF h ,Ll"� Ior"& .. GREATER ANCHORAGE ARLI. BOROUGH ;I oNt,leruu PeUiSCT10N �ytia;^ Department of Environmental "C" Quality 2 6 10-77 3330 St., Anchorage, Alaska 99503 - 274-4d1Y F F , / RECEIVED REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES' 1. Type of Inspection:' CMRO VA FHA CONV x 2. Property Owner: Kathy Swires 343 Mailing Address: - Day Phone (E20— y 3. Name of Buyer: David Berry Mailing Address: Day Phone 4. Name of Lending Institution: Alaska National Bank of the North Mailing Address: Pouch 7-010 Calais II Phone'278-4581 5. Name of Realtor or Agent: Hansen / Ohrt (Dick Brown) Mailing Address: 401 E. 36th. Ave. Phone 279-0491 6. Legal Description: Lot 11 Blk. 6 Lake Ridge Terrace S/D Location: Eagle River 7. Type of Facility to be inspected: Home No. Bdrms.3 8. Water Supply Type of Supply: Public Utility Individual x If Individual, number of dwellings presently served 1 If Individual, depth of well Sewage Disposal -System Type.of System: Public Utility If Individual, date of installation _ Individual (on-site) x �`���'E �.-w �... �-. �� ■� Rei e �� s Department of Health and Environmental Protection Request for Approval of Individual Sewer and Water Facilities Legal Description: Lot 11 Block 6 Lake Ridge Terrace Subdivision Affadavit Attached: ( ) Letter Attached: ( ) 7Approved: Date:rov Date: Department Worksheet: 3'yl t r Wi GREATER ANCHORAGE AREA BOROUGH 1\0 D� Department of Environmental Quality`i 3330 "L" Street, Anchorage, Alaska 99503 274-4561 Date Received Time of Inspection 93'6'4..7 pate of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR 0 ovv- 1. Approval requested by: )L-aSii,I 1�A j ,)r —,11c Mailing Address: r', . yi c�;o r'%,<1a+�A� Phone:'? 2. Property Owner: 114,(P10 y 4 0.74 c i-CY Phone: 6�1 a' n' Mailing Address: 5 R A'ou'r&, a �c 'ills' C'huG i., 3. Legal Description: ,'toi %/ , k/p 't f�f �a� c y in r e',p p� x 4. Location, �7rr /,c- 5. Type of facility to be inspected No. of bedrooms f"At" .r ot- 6. Well Data: A. Type .%,. B. Depth C. Construction- D. Bacterial Analysis 42-I -%1 7. Sewage Disposal System: A. InstalledB. Installer1,h',7i`' C. Septic Tank: 1. Size %Cir c' 2. Manufacturer D. Seepage Pit: I. Absorption Area D Z 2. Material E. Disposal Field: Total length of lines 8. Distances: A. Well to: Septic tank %C ..Absorption area i`f r F Sewer Lines Nearest lot line , Other contamination B. Foundation to septic tank Absorption area C. Absorption area to nearest lot line EQ-034 (1/74) Page 1 of two pages •':;Page 2�of two pages - Rist for Approval of Individual?er &Water Facilities 11e,9e1 Description } r Comments ApprovedDisapproved Date Approval,Val,id for one year from date signed Greater Anchorage,Area(loro9dW,-Department of Environmental Quality } DIAGRAM OF SYSTEM f' accurateythat trepre en tion ofLthe subjelun 111C4e erya wayeryfacilities and hese facilities 3 are operat' g s isfactorily.G%/ Date SIGNED i EQ -034 (1/74) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF ENVIRONMENTAL QUALITY - 3330 "C' Street, Anchorage, Alaska 99503 — 274.4561 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES 1. Type of Inspection: CMRO VA FHA CONV - 2. Property Owner: Harryand Madeline M. Mackey Mailing Address: Star Route Box 1175 Chugiak, Day Phone 688-2813 _ _r Danny and Kathy Swires Mailing Address: Day Phone 4. Name of Lending Institution: Alaska Bank of the North Mailing Address: Pouch 7010, Anchorage Phone 277-5511 5. Name of Realtor or Agent: Mailing Address: Phone 6. Legal Description: Lot 11 Block 6 Lakeridge Terrace Subdivision, Eagle River Location: Hillcrest Circle 7. Type of Facility to be inspected: Single Family No. Bdrms. Three 8. Water Supply Type of Supply: Public Utility Individual XXX If Individual, number of dwellings presently served If Individual, depth of well 9. Sewage Disposal System Type of System: Public Utility Individual (on-site) xxx If Individual, date of installation EQ -037 (1/74) EA V 'r, ,b ys��3�'\\,� JAWp�'°.. �.,�: •. "iii8r USA ya �a Y Z �!(� ° :fir E •1 ' RI N N� in 0°a Jrir ate+ d to o, z•o�. sAN,p ' - - llk CL qY �txtST/nJG Gi.'nuuD 5-(JRFlf<-C 0 rl s b Q 7 o STI t y 41 4 a.. S