Home
My WebLink
About
KNIK VIEW BLK 3 LT 2
K nls k View #051-031-50 Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 JAGS 9'ZQ33 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: (5-SP/3/01q PID Number: O 5 / 03/ S a Dwelling:�& Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New A Upgrade Name: ^^E1<) IJ cry/6l S e, ,�.td�,r- ABSORPTION FIELD — 5%/l1i ❑ Deep Trench ❑ 9hallow Trench ❑ Bed ❑ Mound Address P.O. O BOX 6 7eT5 5 3 . ❑ OtObr Phone Number of Bed ms Sal Rating Total depth from original grade GPD/SF FL LEGAL DESCRIPTION Depth to pipe Invert m original grade Ft. Gravel depth each pipe Ft. Subdivision / / f Block Lot Fill added abo original grade FL Grav ength Ft. Township Range Section Gravelwid Ft. Beds: Number of 'nes Distance between lines FL SEPARATION DISTANCES To Septic Absorption Lift Station Holding . Sewer Total sorption area Numberof nches Dist. between trenches From Tank Field Tank Line Ff' Ft. Well A1,4 NA IVA IVA SIA TANK 'Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer n a _ ' A66 Capaaty ZS 0 Gal. - - Surface Water /Q(i � /Ba fi Material Number of compartments 1ti/Q if/d% Lot Line /0 � % ew_ Z NA Foundation !D O ' _ LIFT STATION . Manufacturer Capacity Curtain Drain _ _ ,_ .— Gal. Remarks Pump on level at Pump off level at h water alarm at in. in.. in. _ Pump male and model Els trioal Inspections performed by InstallerPIPE MATERIAL House to tank P✓Tank to v C_ � drainfield o Drainfield CO/MT Inspector NJ/�� BENCH MARK (Assumed elevation) /d C) 8 Inspectiont" S // dates: { /132n° / rill? Location and description 3m � r� /3 4m COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineers Stamp A�� Conditional Approval: Date a4�,�n+�� e hX a SFW 3 < xc eau t ry s- PA Approvedd l Date -2 7 off 3 �'t el3 Inspection Report 9- -12. c Alder Leaf Court 10' Utility Easement Water Key .xisting Trench MT T 15� M ' MT CO fa S�OPe\ 20 �� q� RECORD DWG MEASUREMENTS A B ST C01 52.5 48 STC02 59.5 54 DCO 64 59 Decommissioned ❑lol Septic Tank Replaced With New Septic Tank Lot 1 O O TI Z O 3 h h r0 U N 11 CD 0 0 D N LA 3 N Q m A C+ O 3 m A D N 0 3 CA 3 n o S 00 -0 T P C (O O rp 3 N A h O 3 i V)cc) o OD Q:N O 3 p p _h O 3 p A 3 O 1 h 3A 3 C7 Ap Qp r0 3 O O h rD C < \\v p h 0 0 3 -0 ii 0 O �D N_ 3 1 (0 11 n Q 3 O z h 0 to ro h f (0 r0 3 V) rD U h n P 3 77 R° --I i r0 3 n 5 m v C) C) rq v0 o O v v O O TI Z O 3 h h r0 U N 11 CD 0 0 D N LA 3 N Q m A C+ O 3 m A D N 0 3 CA 3 n o S 00 -0 T P C (O O rp 3 N A h O 3 i V)cc) o OD Q:N O 3 p p _h O 3 p A 3 O 1 h 3A 3 C7 Ap Qp r0 3 O O h rD C < \\v p h 0 0 3 -0 ii 0 O �D N_ 3 1 (0 11 n Q 3 O z h 0 to ro h f (0 r0 3 V) rD U h n P 3 77 R° --I i r0 3 n 5 On -Site Wastewater Disposal System Permit Permit Number: OSP131094 Tax Code Number: 05103150000 Work Type: Septic Permit Effective Dates: May 13, 2013 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 to May 13, 2014 Design Engineer: NORTH RIM ENGINEERING Subdivision: KNIK VIEW Site Legal Address: KNIK VIEW BILK 3 LT 2 G:1557 Owner/Address: SEYMOUR DAVID A PO BOX 670953 CHUGIAK AK 995670953 Site Mailing Address: 21500 ALDERLEAF CT, Chugiak This permit is for the construction of: /G-/-3 E 7,00 Lot Size in Sq Ft: 51160 Total Bedrooms: 4 N Disposal Field Y Septic Tank N Holding Tank N Privy N private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Dater/ /3 MUNICIPALITY OF {r Community Development Department Development Services Division —� On -Site Water & Wastewater Program ANCHORAGERUSH! Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 05/— 031-50 Property owner(s) Se 4 "our�a�tol Day phone 221?— G 15-q Mailing address _2 /5"dO A Ids ria, (27 - Site address _5k, o__ Legal description (Sub'd., Block & Lot) A -'j t (<_ V Legal description (Township, Range & Section) Lot Size 5 16a Sq. Ft. APPLICATION IS FOR: (® all that apply) Absorption Field ❑ Septic Tank co Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms LZ APPLICATION IS AN: TYPE OF DWELLING: Initial ❑ Single Family (SF) ❑ (w/wo ADU) Upgrade ❑ Duplex (D) El❑ Renewal Multiple Dwellings ❑ (SF and/or D) THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property or authgfized agent) Permit/Rush Fees: — Date of Payment: Receipt Number: 0L(51 (e Permit No. ©SQ I3lOqq Permit App_9-1-12.doc Waiver Fees: Date of Payment: Receipt Number: Waiver No. NINEERING Date: 5/13/13 To: MOA On -Site Services MEMO Steve Eng, PE, PH (907) 694-7028 tel NorthRimEng@aol.com Subject: North Woods S/D, Block 4, Lot 12 Number of Pages: 4 I followed Debby's direction for septic tank replacement design. The owner is under hardship due to tank failure -system has backed up. Please review as soon as possible. We are using IX gage heavy duty replacement tank due /to depth of cover. 1 7 �i�� cotis�� �c7` iva vcG'i If there is need for additional infoirnation or clarification please give me a call. Thanks -Steve €f (' INEERING Knik View S/D, Block 3 Lot 2 SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is an existing 4 -bedroom, single family home. Most of the neighboring lots are developed. The current septic tank has failed- the trench is still useable. This is an emergency situation -sewage backing up. These lots are large and are served by public water. No adverse impacts are expected from tank replacement. The lot easement is located on the drawing and is not encroached upon. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. • Two compartment, 1250 gallon llZgage septic tank. Watertight couplings on inlet & outlet. Heavy duty tank due to deep burial. • 5' minimum between the tank and bed. 10' to property lines. • 10' of cover or less for heavy duty septic tank. • Tank & solid pipe must be set on well compacted, stable soil. • 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. • All cleanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2% slope. • Septic Tank to be pumped every two years or when required. • Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) M I Alder Leaf Court 10' Utility Easement Water Key/�ox / I DESIGN NOTES 1. Existing Trench Remains In Place. 2. Sewer Service Line minimum 2% slope. 3. Replace/Decommission Old Tank. 4. Lots Served by Public Water System. 5. No Conflicts Within 200'. 6. UseGage Replacement Tank. xisting Trench 5. Maint in 10' cover or less. MT CO ! \ S�oPe 15 ° MT CO S PQ Deconmisslon ❑td Septic Tank Replace With New e Septic Tank SvoP 30� lJt, ,> Lot 1 o, s\EL N` O Y +' £ vj d H £ 0, O � d d 0 o rn S d O ULo LO £ (1J Q S O c H O L U, F £ 0 > U >U O Ii Wm U U Ul d __ X xw M e - O I W 3 —i H H L. O Z LLJ q � � W W Y U Z Q = Q J U ~ n - Z W LTJ U_ oe� � Y ~ � z W Q F— U O U u i O O 0) Y C3 > d c O U S ~ U U U_ 0 O Q i D- O p oi L7 a U a O a, T d d L7 F d LA d L7 O N .a yi (V Z £ £ +' O £ OY T. � + d> W £ d~A 0, O. £ p U U 0- O )Ln (Ij O -C T "u +' > £ O O. d - 0 co0,�a 0, Vi 0, J 3 O O__ £ o7i O p W F-dS V- NU a U ND D)Y_>+'U S p�C0 0 W p +p d L7 i _� O U r 0 £ Ut Y F- NF-- W 4 U F- O Y O T)i O"N NiVpi"300~ O d 0) 0D vv v3v¢OaNLD zN w 1=� _; N M d' U7 iD I -I co M e - O I W 3 —i H H L. O Z LLJ q � � W W Y U Z Q = Q J U ~ n - Z W LTJ U_ oe� � Y ~ � z W Q F— Municipality of Anchorage t M°•, Development Services Department Building Safety Division .I T On -Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page ( Of 3 www.ci.anchorage.sk.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SWODO c PID Number: 05-1 193t `S© Name: PD' I O✓1'ICS Wastewater S stem: Y N New Upgrade Atltlreu: aiuoiri ' ABSORPTION FIELD Phone: 3q / :9_5 Number of Bedrooms: `"% bU( O Deep TrenchxShallow Trench t] aetl ❑ Mound O other: LEGAL DESCRIPTION B° R°""° Tote) Depth from original grace:7 e GPDIFP FI. Block: 3 Lot: Subdivision vile /QitC Depth to pipe bottom from original 19: Greve) depth banuth pipe: q I<n;k Ft. Fl. Township: Range: section: Fill added sbova original grade:/3. 5 -Ft ` Growls Length: 0Ft. Well: ❑ New ❑ Upgrade Gravel width: Number of Ilnin; Dbtanca ba wash lines: Ft. Ft. CI fication (Private, A, B, C): Total Depth: Cased W: ; �- T Ft. Total absorption are°: jaD Fe Pipe Material: Q303 F8/o Driller Data 6tegc Water LevN: Ft. Installer: �h Data Installed: S Yield: camp Sat at: Haight Above Grountl: TANK GPM Ft. FL SEPARATION DISTANCES KSeptic ❑ Holding ❑ S.T.E.P. ❑ Other: To From I Septic Tank Holding Tank ublic/Pdvate Sewer Line an octurer: C l �S auty. o Gal. —� c " Material: ,r /D P H Nr of Com ertmenlc. pWell surlaca Water f Eftgon LIFT STATION Lina ^t�L rse: enu ecturer.Lot !/Gal.' Fduntltlion `� " `�In. "Pump on" Ieei at fP level al: igh water alarm at: in. In. °°rtaln Drain Pump Make b Model cal Inspections performed by: Remarks: a I o r 4D p _174C-ft„t µ, f ,yT BENCH MARK 66.q ` /r'L Location and Descripti a oT IryttN C- D QAcK %t t�6 r �Ir �QDsumed aUct. Heal in FI. O It o o y a........ '1h �P(� S i S ENGINEERING Inspections performed by:17034 Eagle River Loop Road, Ne, Wks: 1" Q 3 Illinib River, haw Alaska 99577 tad __p3 C. COWAN Developme t Services Department Approval y ROBERT y 'a;, CE-8801Z'MiF roved b Reviewed and a J/ PP Y ate: ( t1 D p r.3e�oy'��i4J PERMIT No. SW020330 PAGE 2 OF 3 Municipalit of Anchora e DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.D. Box 196650 *Anchorage, Ataska 99519-6650 • Tetephone 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 2, BLOCK 3, KNIK VIEW S/D P.I.D. NO. 051-031-50 ----------------------- SURFACE WATER ALDER LEAF COURT - -- 10' UTILITY EASEMENT-KEYBOX --- ----------------------- qr i THAI. LOT 1 HEyI TRENCH -MT1 I 4 MTH#2 O1 > N LOT 3 CO2 pLT�S�T� i DBLI do DBL2 TMT ® ST2 NEW 1300 GALLON ® ST1 HDPE SEPTIC TANK > 9 ALE: 1" m 40' qs`a C;, FCO TBM ? BA,. ......:;� NEW ROBERT C. COWAN2� 4 BEDROOMs°• C"88 1 HOUSE PERMIT NO. SW020330 PAGE 3 OF 3 Municipalit of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Ataska 99519-6650 • Telephone 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 2, BLOCK 3, KNIK VIEW S/D P.I.D. NO. 051-031-50 FINAL GRADE NEW 84.3' 1300 GALLON POLYETHYLENE SEPTIC TANK 2" INSULATION • •2 MT1 • • ■ 11� FINAL GRADE • 70.9' •INSULATION IN PI • • * = OFFSET iR SCC R(.n eaKS� N. T. S. MT2 = 66.9'-//' 6.9' MT1 = 69.2' _..,m4p� Ak NO WATER FOUND 57.9' B.O.H. Municipality of�nchorage P.O. Box 196660 • Anehoxage, Alaska 99519.6660 •Telephone (907) 843-8301 •Fax (907) 843-8200 4700 BragaaStreet •Anchorage, Alaska 99507 www.munl.arg Mayor Mark Begich g�ding Safety Division 12/23/2004 S&S Engineering 17034 Eagle River Loop Road No. 204 Eagle River, Alaska 99577 Subject: Waiver Request for Knik View Subdivision, Block 3, Lot 2 Waiver Request #WR040098 Parcel ID #051-031-50 HAA#HA040669 ,m Pict -4 m tLZO.Qo� Dear Mr. Cowan: Your request for a waiver of the required 100 feet horizontal separation from the absorption field to surface water has been approved. The approved separation distance is 91.0 feet. This waiver approval applies to the costing ,absorption field to :surface water separation only. Any future upgrade to`-Ihhe 'prl-site :wastewater disposal; system will require all . separation distances be suet or another approval from this departrnent. If there are any finther concems or questions regardin at 343-7904. Sincerely, ulietlSYiQ� akela, P.E. Civil Engineer On -Site Water & Wastewater Program is waiver, please call our office Community, Security, Prosperity Municipality of Anchorage Development Services Department • mar Building Safety Division s e. On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchorage.ek.us (907)343-7904 Waiver Review Worksheet WR#:'M040098 PID#: 1. 0 HAM MA040669 Permit#: 4+_'nanw Date Received: 12/23104 Legal Description: ICnik View Subdivlslon Block 3 Lot 2 Engineer. S&S Enalneerina 17034 Eaa1d River loon Road No 204 Eagle River, Alaska 9 577 Applicant: Wood BAilt Homes Waiver Requested -91 feet from absorotlon field to aurfaca water Criteria: Geology Points: A. Water Table S. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: Waiver Is Granted: Waiver Is not Granted. List Conditions or Reasons for above: Date: By: %ioll la 01 Kavlawer Rec#: 62025 Amount $1.150.00 Date Paid-.AM/2004 M S Bt HEALTHAUTHORITY APPROVALS SEWER&WATER AWN EXTENSIONS SEWER&WATER INSPECTION ENGNEERINGSTUDIEs ANDREPORTS WELL INSPECTION &FLOWTEST SITE PLANS PERCOLATION TEST STRUCTURAL& AEONANICAL INSPECTIONS ONSITE WASTEWATER OISPOSALSYSTEAI DESIGN December 23, 2004 MUNICIPALITY OF ANCHORAGE Development Services Department P.O. Box 196650 Anchorage, AK 99519 REFERENCE: Lot 2; Block 3; Knik View Subdivision ROBERTC. COWAN, P.E. ROBERTA. SHAFER, P.E. CML ENGINEERS (907) 6942979 FAX(907)694-1211 This is to request a separation distance waiver between the septic system leachfield serving the subject property, and surface water running on the neighboring property Lot 3; Block 3; Knik View S/D. There is a twenty foot section that is within the mandatory 100 foot minimum separation distance, the closest measurement being 91 feet. It appears that the water running in the low lying area was moved sometime after the septic system was installed (9/2-9/3/03). There is evidence that fill was placed on the other side of the surface water causing its diversion. At the time of septic system installation the separation distance was measured at 100 feet. The following is a justification for the requested waiver: 1. The topography is such that the travel distance any surfacing effluent would take exceeds 100 feet. There is a ridge in the way of the shortest distance to the surface water (see attached site plan). 2. The pathway that the effluent would have to take to reach the surface water is through a heavily vegetated area. This would have the effect of slowing migration and treating the effluent before it could reach the surface water. 3. The end of the trench closest to the surface water is clearly visible from the driveway. The occupants should notice any surfacing effluent and take action to stop it (if this ever occurs). We do not anticipate any adverse effects,on the neighboring properties by the granting of this waiver. With the approval of this absorption field to surface water waiver, we are also requesting Health Authority Approval. If you have any questions, please contact us at 694-2979. Sincerely, RobertC. CowanL�P.E.— RCGmjetwaivedolmstead 17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577 = 40 WAIVER REQUEST SITE -PLAN r C I m r W 0 lin O I y �0c I I Z 1�� x l mZ a I A mf m mr n o c^ 10 tim � N no R Z n A Az I � I omz n N N m O M I I m w p N~ n11 o is lr > I r C m r W 0 I � I I =r x 0 I a I A I � I ri > (A c n N N Cil M I I m w p Z > I A I O I rl r < �o y o I IEYIER&WATEB 4WNEVEN9ION9 .8EWER&WATER MPECTKW r"awEnm9tUDO AMAEPORTS WELL36PECT104 6ELCW TEST SITEPIANS WAD DESIGN BMTEST PERcat UM TEST STMXTURN.A WOWSCAL NSPEC11dA ONSITE WASIEWATER WpoSALSYSTOA OESION nG Date, 1 - 16'-43 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES 825 L Street P.O. Box 196650 Anchorage# Alaska 99519-6650 REFERENCEI Laf.�9Wk3,kon;kOiCu. n0BE1TC. COWAN, PE. n00ERTA. SNAFEn, P.E. CIVILENGINEERS (907)694-2979 FAX (907) 694-1211 The septic inspections for the referenced property were performed on wate(J' and a-03 . Prior to submitting the On-site WaAs er -Disposal System and or 11 Inspection Report we are waiting for the �,' -6AaA to be completed. SKYVey If we may be of further service please contact us. Sincerely, Robert Co Cowan, P.E. r 171134 NORTN EAGLE RNER LOOP 4 SUITE 204 6 EAGLE RIVER, ALASKA 99517 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Renewal 4 Pw, o',3C)P Kt) Date Issued: Sep 05, 2002 Expiration Date: Sep 05, 2003 Permit Number: SW020330 Parcel ID: 051-031-50 Legal Description: KN IK VIEW BLK 3 LT 2 Design Engineer: 0003 S & S Engineering Site Address: Owner Name: R&S Homebuilders Lot Size: 51160 SQ. FT. Owner Address: PO Box 521577 Total Bedrooms: 4 Permit Bedrooms: 4 Big Lake , AK 99652 - This permit is for the construction of: [✓] Disposal Field Z✓ Septic Tank ❑ Holding Tank [] Privy ❑ Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued Issued By: Z Date: '11r /0 -1— Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWERMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. O -" — 0 7/— S 0 Permit Number SW020-730 Property owner(s) R '�_s f{o m d ev a a,� Day phone Mailing address (1) P -d BO x Sa / i 77 Mailing address (2) 8(C- LAn C y /Iik Zip Code q 9 6.r 1 Legal description (Lot, Block & Sub'd.) LO T a- Q L a c -1c 3 K fv l K y i f w S'ly Legal description (Section, Township & Range) Lot Size -S / , / (DO Acreso THIS APPLICATION IS FOR: Number of Bedrooms I Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. 5 & S ENGINEERING 17034 Eagle Rive' LOOP Road No. 204 �j� � c.,..�e Rivnr. Aleske 99577 (Signature of property owner or authorized agent) Date of Payment: Receipt Number: (Rev. 12100) Date of Payment: Receipt Number: MUNICIPAL17Y OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Renewal Date Issued: Sep 05, 2001 Expiration Date: Sep 05, 2002 Permit Number: SWO10358 Parcel ID: 051-031-50 Legal Description: KNIK VIEW BLK 3 LT 2 Design Engineer: 0003 S & S Engineering Site Address: Owner Name: Ted Schmelzer Lot Size: 51160 SQ. FT. Owner Address: PO Box 999 Total Bedrooms: 4 Permit Bedrooms: 4 Neches , WA 98937 - This permit is for the construction of: Z Disposal Field F,?] Septic Tank F-] Holding Tank F-1 Privy ❑ Private Well Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: 0 Date: I — t; —49 ( Date: ��—Q� go Municipality of Anchorage • Development Services Department t�oa oO. Building Safety Division On -Site Water and Wastewater Program s' . 4700 South Bragaw St, P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 RECEIVED ON-SITE SEWER/WELL PERMIT APPLICATION JUL 23 2001 FOR A SINGLE FAMILY DWELLING MuniclpailtycfAncborage Parcel I.D. OS / — O3 / — 5'0 Permit Number SWO/O .M Property owner(s) TQ 0 S c M' t 2. It .4 Day phone 6 �"6Tg g Mailing address (1) P-0 • Lf 0 X q 9 q N h cN& S w# Mailing address (2) Legal description (Lot, Block & Sub'd.) L 00 Legal description (Section, Township & Range) Lot Size ZT / J / G 0 Acres& THIS APPLICATION IS FOR: zip Code cTS g 3 7 a BLocre 3 Kpiix view Vo Number of Bedrooms Sewer Only N Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. r A f, 5 ENGINEERING 1 17001 Eagta River Loop Read No. 204 Eapla River. Alaska 99577 (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Waiver Fees: Date of Payment: Receipt Number: Receipt Number: (Rev. 12100) .t „I MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On -Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Sep 05, 2000 Expiration Date: Sep 05, 2001 Permit Number: SW000355 Parcel ID: 051-031-50 Legal Description: Knik View, Lot 2, Block 3 Design Engineer: 0003 S & S Engineering Site Address: unknown Owner Name: Ted Schmelzer Lot Size: 51160 SQ. FT. Owner Address: PO Box 999 Total Bedrooms: 4 Permit Bedrooms: 4 Neches , WA 98937 - This permit is for the construction of: F✓ Disposal Field � Septic Tank F� Holding Tank F� Privy ❑ Private Well El Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 1 BAAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: 7/7/0d Date: tIR MAwmor n A'PRovks l k"AWATtAA AWNEMENSIONS bt*EA6WATtA WSPEOTM,4 ENOINEthW8TUbIE3 "AEPOWS WELLWPECTION inmtEst SAEPLANs AoAb0t3K N fiottst k*O Arn7I4 hat itNUcnalAit I ttPEctbF� N �tE�4At�R ebNAl9rettlA ROBEhT t:. COWAN, P.E. Mt.tOGINEERS (907) 6942979 August 10, 2000 FAx (9o7) 694-1211 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AY, 99519 REFERENCE: Lot 2, Block 3, Knik View S/D It is requested that you issue a permit to install a septic system to serve the proposed four bedroom dwelling on the referenced property. A test hole was excavated and a percolation test was performed. The approximate location of the test hole is located on the attached site plan. At the time of excavation 7/20/95 water was not found. After ground water monitoring, no water was found. We do not anticipate any adverse effects on neighboring wells, septic systems, reserve areas or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any of the adjacent properties. If you require additional information, please contact us. Sincerely, ,-1&z1ae,— Robert C. Cowan, P.E. RCCN Enclosure i t03d kOWW kAGLE WAR L060 A §Ultl: 304 A i:AGLE WAK AtMKA 99577 SITE -PLAN DESIGN 1" = 60' I 03 lWM a 'o NOO� N z N I NII C) Z� Zi�rrIm zm � f) Hgo %ity ops O (rl z ` y + v oov dpi 0 V� s 0 CA n �8= o I'm 0 ,00�fjy i m v". U I r I o ro P-3 o < m 9 I ----------------------J1 ------------------- KNIK VISTA DRIVE �Z� I 0 " I NII � O � Hgo %ity �n n rcnio � IIs + v oov dpi v O 11� ��II�-^ V� n �8= o I'm �a0 � a� ,00�fjy i m v". U Y 100' MIN. of V -V 4� s %5 Q V V I ' I fTl Q I r I o ro P-3 o < m 9 I ----------------------J1 ------------------- KNIK VISTA DRIVE �Z� I NII � W � N Ln0 o N 0 Q I fTl Q � o n � ID z IT1 co C ' I z I O r o I � von zm0 El A D y zs O y O O y y � z noo V j n s < y C y m m i Z N m n I O Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG - PERCOLATION TEST ry PERFORMED FOR: IIIA S(,,► N(ri li?�iL� DATE PERFORMED: 17"? oeE o LEGAL DESCRIP ` fT1�., QE�Efl \ 2- 9- 96 3- 3 to- 01213 4- 12- 13- 6- 67 14- 1415 7 is - 19 19 bf— s w talo WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? I)Ry ID --q---10 Depth is waer alworUp? Section: SITE PLAN ROBERT C. COWAN =®mmm 20 { III PERCOLATION RATE 7— (mmutes/inc0) pERC MOLE DIAMETER syr r'' CIA TEST RUN BETWEEN 1 FT AND < FT Tf COMMENTS • # +A PERFORMED BY: 5 i S ENIGINRE BRING a Np gpI CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WIT��QSrpeANTi11�p.�L GUIDELINES IN EFFECT ON THIS DATE. DATE: $'•� `' S Eag a war, as a !/ 72-008 (Rev. 4/65) 8- 9- 96 6 . to- 01213 12- 13- 14- 1415 is - 16 16 17 19 19 bf— s w talo WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? I)Ry ID --q---10 Depth is waer alworUp? Section: SITE PLAN ROBERT C. COWAN =®mmm 20 { III PERCOLATION RATE 7— (mmutes/inc0) pERC MOLE DIAMETER syr r'' CIA TEST RUN BETWEEN 1 FT AND < FT Tf COMMENTS • # +A PERFORMED BY: 5 i S ENIGINRE BRING a Np gpI CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WIT��QSrpeANTi11�p.�L GUIDELINES IN EFFECT ON THIS DATE. DATE: $'•� `' S Eag a war, as a !/ 72-008 (Rev. 4/65) PERFORMED FOR: LEGAL DESCRIPTION A DEPT/) //Y///� E TI 1 � 2 1a 4 • 5 v,r 6 9 �T 8 9- 10- 11 10 11 ~% 12- 13- 14- 15 2131415 y r s• 16 17 18- 19- 20- COMMENTS 81920 COMMENTS WAS GROUND WATER ENCOUNTERED? 106 / S IF YES, AT WHAT I�/k L DEPTH? !! O _ P — — j E lleplbMontt W Weler Monitoring? pale: Reading Date Gross Time Net Time Depth to Water Net Drop a • I 8 CoA 3 ' y tftr.� m Y71'4- YL PERCOLATION RATE (mmutevinch) PERC HOLE DIAMETER G TEST RUN BETWEEN G FT AND 7 FT PERFORMED BY: S i S ENGINEERING i,('/� � / /7�CEF 17034 Eagle Iver p �� FI ��99�� ACCORDANCE WITElab6 Rj*-J� AMysllg,odrML GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 IRev. 4/85) THAI TIS IE � WAS PERFORMED IN �l/p0 t WEALTNAu HOPATY APPROVALS BEWEgLWAttA MANWENStONS hMRLWATER WSPECTION t"NEEMNGSTUCIES ANOREPoprs WELLMSPECTION APLOWTESt Eod.tEst kftounow tEst �a motc"ONs W MAtt" B16hoiSIgNALNymm W 11013EMT C. COWAN, P.t. CWIL ENGINEtAs (907)694-2978 FAx(907)694-t2tt ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE: Lot 2, Block 3, Knik View S/D August 10, 2000 GENERAL: 1. The scope of this project includes the installation of a 1300 gallon Premier polyethylene septic tank and a drainfield trench to serve the proposed four bedroom residence located on the referenced property. 2. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The contractor shall be responsible for obtaining any necessary underground utility locates. 4. Unless specifically agreed otherwise, the property owner shall -be responsible for final grading areas subsequently depressed from soil settling. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. (7«t4 NOW H WL@ NAM LOOP A §Uftt; 964 8 EAGLE "Ft, ALASKA 99371 Page 2 Lot 2, Block 3, Knik View S/D August 10, 2000 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 4. Septic tanks installed with less than 4 ft. of cover shall be insulated. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed -up) before gravel (sewer rock) placement. 2. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page 3 Lot 2, Block 3, Knik View SID August 10, 2000 MINIMUM MATERIAL SPECIFICATIONS: 1. Any septic tank proposed for installation must be constructed by a Municipal approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: LTe of Eike Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. 7. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever requirement applies. INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: Page 4 Lot 2, Block 3, Knik View B/D August 10, 2000 The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre - construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTORANSTALLER Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel 1. D. QS"1 — 031—szt 1. GENERAL INFORMATION Complete legal description HAA # 0gQ10 q Expiration Date: Location (site address or directions) a 1.:1AQ e"-J&9_L4L+✓f Current Property owner($) w B a A u u 1 � r H o •N t j Day phone 3 V 6- .19 P r Real Estate Agent Mailing address Cl a 37 A ur�mw Ata Ct G,Ac,a 4 N.�c,q , A., 9gs'o 7 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: y 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site . Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System $I Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water. samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm S & S ENGINEERING Phone 6Y 9- nt 9 7 9 g e KIVer LVOF Road No. Address Eagle River, Alaska 99577 Engineer's Printed Name R46t.4-7 C._ Co c,,'+,.w Date f x/ V - o y SAG OF 5. DSD SIGNATURE �.i, RO�� CE - C8801 ! 2' COWAN %�4 V�, i+ Approved for _ bedrooms. Q lFs�`w.. <_�= Disapproved. tlttZ���i'5�d+" Conditional approval for bedrooms, with the following stipulations: (ff(I Additional Commentswil QAl •. 0 = ATERA PROGTER Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By: �l L� O�S� Original Certificate Date: pL1_ (Rev. 0102) Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description:} L_ , • cK 3 • Kk IK V, r 1.0 Parcel ID: 051"031 50 A WELL DATA t Well type If6)B, or C provide PWSID # _ Well Log (Y/N) NO Date completed = Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth , -- ft. Cased to ft. Casing height (above ground) — in. FROM WELL LOG AT INSPECTION Date of test _ Static water level - --ft. ft• Well production 9.p -m. 9— p.m-WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg./I. Other bacteria colonies/100 ml. Arsenic: mg./I. Date of sample: = Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material EPR / 11i% Date installed Z b Tank size '1 900 gal. Number of Compartments Z Cleanouts (DN) `les Foundation cleanout Depression over tank (Y/® LX). High water alarm (Yf + : �l Date of pumping Pumper fJ14 C. ABSORPTION FIELD -DATA _ _ �- Date installed ILL Soil rating (g.p.d./ft2 or ftZ/bdrm) _2 System type 5l+r}t t our TSE Length 50, ft. Width so ft. Gravel below pipe I ft. Total depth ft. Eft. absorption area -�2O ft2 Monitoring tube `ii<S Depression over field Date of adequacy test P410 3t�5lZS wN Results (Pass/Fail) For t� bedrooms Fluid depth in absorption field before test = in. Water added= gal. New depth= in. Elapsed Time: — min. Final fluid depth = in. Absorption rate >= 9-P.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) C) If yes, give date — Date installed "Pump on" level at _ in. Datum ^ E. SEPARATION DISTANCES Size in gallons "Pump off"level at — in. Cycles tested Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: NO W&c.t.. e)O l- Cc -T- Septic T Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer /septic service line _ — On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank SEPARATION DISTANCESFROMSEPTIC/HOLDING TANK ON LOT TO: Building foundation t T Property line r�' Absorption field S �t Water main Ot + Water service line l �+ Surface water 1 CSO ,+ Wells on adjacent lots i GP4 SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 32' Building foundation S3 Water main io Water Service line ( f I" Surface watery i r' Driveway, parking/vehicle storage I F Curtain drain Nog& xmowtj Wells on adjacent lots F F. COMMENTS G. ENGINEER'S CERTIFICATION N 1 certify that / have determined through field inspections and r r review of Municipal records that the above systems are in Of conformance with MOA HAA guidelines in effect on this date. gf�i i /t ROBERT C COWAN Engineer's Printed Name R 8/Jd-c.T C- e>>✓Ar 1`cs CE -8801 1Il rFW Date i ,LO p y tt ��D p.. _...• ,%ll_ A�r[�oS+ _w HAA Fee $ S7- 'T-1 Jq6,6b Date of Payment f 34 ao / a M 1 � Receipt Number a G 1 9 o S r "I (Rev. 12/01) in. Waiver Fee $ j 1 n6-3 cb Date of Payment lf�l Receipt Number LOT 2 BLACK 3 HAS 51,160 SQ.FT. OF AREA ALDER LEAF COURT ' - e - Woodbuilt Homes ,� I CURVE TABLE GRAPHIC SCALL I nch = 40 Feet CURVE DELTA RADIUS LENGTH C7 '11015.62' 1 9.68-1 40 io a to ea 40 so VERTICAL DATUM WAS ASSUMED Engineering & Surveying, Inc. 9330 Vanguard Drive, Suite 203 D Anchorage, Alaska 99507 (907) 562-6050 12-06-04 1" 40' id AS -BUILT 1557 2401150 I hereby certify that the property described hereVnhas -been surveyed by me, or at my direction, and that the improvements situated thereon are within the property linea and do not overlap or encroach_" the property lying adjacent thereto unless otherwise shown. That mp„ - improvements on the property lying adjacent thereto encroach.,on the premises in question and that there are no roadways, transmissions— lines or other easements on said property except as shown. It is the responsibility of the owner or builder, prior to construction, to verify proposed building grade relative to finish grade and utility connections and to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. Listed diatancea prevail over scaling. Reproduction may cause distortion. ILot 2 (Block 3 1 ,t 49 rH KNIK VIEW SUBDIVISION CHARLES E. FORBES o` y . LS -7326 ems••. � o� � r "a ' .....••• f� PPoe-ssio0\ \'OSN