HomeMy WebLinkAboutPOLLOCK HOMESTEAD BLK B LT 11Pollock Homestead Block B Lot I I #017-112-37 Municipality of Anchorage • •. Development Services Department Building Safety Division i' Onsite Water & Wastewater Program, 4700 South Bragaw St. "T t P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number. SWO30484 PID Number. 017-112-37 Name: RYAN MATHIAS Wastewater System: ■New ❑Upgrade Address: 13120 LUPINE ROAD a ANCHORAGE, AK 99516 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 240-8430 4 O Deep Trench ■ Shallow Trench 0 Bed O Mound 000wr LEGAL DESCRIPTION s' "°ti4.0 TOW °'°" s wo/se. rt DWG.) rc Block: Lot Subdivision: B 11 POLLOCK HOMESTEAD DWh to pipe kdtum fern or" q,edw SEE DWG. o,"W depth ke,wdh pip. 0.7 n rt Township: Range: Section: ns edd.d oems ergww grew: Gvw wv : _ — — SEE DWG. rt 30 rt WELL: ■ New ❑ Upgrade Growl width: 5 Nunar of enc 1 Olelu.e eetween Ow. — pt n o w watbn prlwle. "C): T.ld Depth: Cowl 0 .drock Told abarpaon arc r+p. malerlat PRIVATE 491 a 40 n 150 sa, rt SCH40 PVC/D 3034/ F-810 asr: ALPINE DRILLING Dow "-d: 6/9420041 slaw wow kwwk 30 kwl n G.E.G. Ltd./•••A+ HOMESERVICES Dote kwee.d: 1/5-7/2004 n YwS pwrip Set AC co.wg NdaM ADew rNound: .5 cell UNKNOWN rt 2 n TANK SEPARATION DISTANCES 13Septic 0Holding ■S.T.E.P. ■Others To From Septic Tank Abso Wn n.% Lin Station Holding Tank /PrNule sew« Lin.. MOiM1l°al"•" ANCHORAGE TANK C P..4' in gouma: 1500 Well 100'+ 1000+ 100'+ — 25'+ STEEL S o/ oampa w: 2 Surface Water••IDo'+ ••too'+ ••too'+ — — LIFT STATION Lal Una 5'+ 10'+ 5'+ — — s:. a eaeww: 1500/76 Monufaeb .. ANCHORAGE TANK Foundation 5'+ 10'+ 5'+ — — llnp M Wwl al: iww 9L Nish waw alum at TIMER 13.5 I TIMER 13.5' 46" 24" Curtain Drain 50'+ 50'+ 50'+ — — " rak" a Nadw: ei`bkal wD"� pw%n,.d kr: /20 OSI 05 HHF M.O.A. Remarks: BENCH MARK uWaaon end 0wanpu TOP OF PUMP VAULT MANHOLE *THIS IS AN ADVANTEX TREATMENT SYSTEM **CURTAIN DRAIN OUTFALLS TO DRAINAGE DITCH Nw wd ewe wn 1 q2.54 R ALONG ROAD FILLED w/ DRAINROCK TO COVER SURFACE WATER. cNciNcems aEAt aoo60C 0 Qr,. '....::.*. *••A+ REPLACED ORENCO FIBERGLASS TANK W/ STEEL TANK IN THE WEEK OF 8/15-20/2004 Inspections G.E.G. LtD. performed by: Dates: 1st 1/5/2004 . ..... .. 0 2nd 1/5/2004 D 3rd 1/7/2004 0 y fess. X0*a Development Services Department Approval °•. E 7953 .. F`�p� �d4p°a Reviewed and approved by: Date: 2 -fl ptw. 12/01) P ��400000�� PERMITNUMBER: AS DRAWING PARCEL NUMBER: SWO SW030484 017-11 12-37 DRAINAGE DRCH I / FlLLED w/ DRAINROCK TH a I NEW DRAINFIELC NEW 1500 GALLON ADVANTEK TANK r L J NEW r 4 BEDROOM I HOUSE TH/z� pqp RABBIT CREEK—ROAD GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS t GENERAL CONTRACTORS 3701 F TLA ROAD. SUITE 101 • AWHORAGF. AK 09501 • PHONE (901)3111170 • FAX (007)518-5746 PREPARED FOR: PHONE NUMBER: RYAN MATHIAS (907) 240-8430 LEGAL DESCRIPTION: POLLOCK HOMESTEAD; LOT 11, BLOCK B TYPE OF WORK: AS -BUILT DRAWING OF NEW SEPTIC SYSTEM C.J.G. .E: 1" = 30• E NUMBER: 2OF3 A B I I I \ \ \ STI 35.50 45.28 MH1 40.65 51.71 MH2 44.50 56.73 MT1 33.60 68.15 MT2 42.84 92.69 RABBIT CREEK—ROAD GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS t GENERAL CONTRACTORS 3701 F TLA ROAD. SUITE 101 • AWHORAGF. AK 09501 • PHONE (901)3111170 • FAX (007)518-5746 PREPARED FOR: PHONE NUMBER: RYAN MATHIAS (907) 240-8430 LEGAL DESCRIPTION: POLLOCK HOMESTEAD; LOT 11, BLOCK B TYPE OF WORK: AS -BUILT DRAWING OF NEW SEPTIC SYSTEM C.J.G. .E: 1" = 30• E NUMBER: 2OF3 PERMITNUMBER: AS -BUILT DRAWING PARCEL NUMBER: SWO SW030484 017-112-37 FINAL GRADE - TOP OF MANHOLE 0901-107 IR, 102.54 (AVG.) TOP OF TANK94.53 \ 11 I I LL ■ I I ly I I /_TOP OF TAN - 94.49 K � �� ..RR11{l G44 1 ORIGINAL GRADE O HIGHEST POINT 102.05 FINAL GRADE - 106.62 (AVG) INSTALLED BRACING AND STAKING — FABRIC INVERT OF PIPE - 104.15 (AVG.) THE TOP OF SANDRj' DISTRIBUTION UNE IS 125 INCH PVC INVERT OF PIPE � 93.74 STEEL E BOTTOM OF TANK TRENCH - 101.057 BOTTOM OF PUMP ' ,�'• VAULT - 94.54 ORENCO PUMP VAULT BOTTOM OF BOTTOM OF TANK - 89.88 TANK - 89.61 ORIGINAL GRADE O HIGHEST POINT 102.05 FINAL GRADE - 106.62 (AVG) INSTALLED BRACING AND STAKING — FABRIC 8/20/20( e.11_% '.� DRAWN BY: _ _.. __. - SCALE; E.W/C., GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS 6 GENERAL CONTRACTORS 1 'j 3701 E T1AOR ROAD. SATE 101 • ANCHORAGE AR 00501 MO1F (007)3]1-01)0 • FM (001)5384246 N. •'S PREPARED FOR: PHONE NUMBER: PAGE NUMBER: RYAN MATHIAS (907) 240-8430 3 OF 3 LEGAL DESCRIPTION: POLLOCK HOMESTEAD; LOT 11. BLOCK B TYPE OF WORK: PROFILE AS -BUILT DRAWING OF NEW SEPTIC SYSTEM 4";w5cms:�eev • 0 INVERT OF PIPE - 104.15 (AVG.) THE TOP OF SANDRj' DISTRIBUTION UNE IS 125 INCH PVC 103.55 (AVG.):,/WITH 3 INCH HODS SPACED 10 INCHES ON CENTER (30 HODS TOTAL) BOTTOM OF RELATIVE ELEVATION OF TRENCH - 101.057 GROUNDWATER 98.80 RELATIVE ELEVATION OF BOTTOM OF TEST HOLE - 94.05 —0 8/20/20( e.11_% '.� DRAWN BY: _ _.. __. - SCALE; E.W/C., GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS 6 GENERAL CONTRACTORS 1 'j 3701 E T1AOR ROAD. SATE 101 • ANCHORAGE AR 00501 MO1F (007)3]1-01)0 • FM (001)5384246 N. •'S PREPARED FOR: PHONE NUMBER: PAGE NUMBER: RYAN MATHIAS (907) 240-8430 3 OF 3 LEGAL DESCRIPTION: POLLOCK HOMESTEAD; LOT 11. BLOCK B TYPE OF WORK: PROFILE AS -BUILT DRAWING OF NEW SEPTIC SYSTEM 4";w5cms:�eev • 0 . ,. RightFax 1/19/2004 7:06 PAGE 1/1 RightFax Inspection Report Municipality of Anchorage, Building Safety Division 4700 South Bragaw INSPECTION: VOICE 343.6300 INSPECTION:FAX (907)249.7777 INFO: 343.7962 Name Address Legal Subdivision Comments or Directions Dave 15340 POLLOCK DR BKBLT11 POLLOCK HOMESTEAD Permit 04-7075 Phone 727-0972 622-6777 Inspection Date 1/19/2004 PM Inspection Ratro Electrical Rsinspsction N \0 NO NONCOMPLIANCE OBSERVED ❑ CORRECTIONS ESSENTIAL AS EXPLAINED BELOW ❑ WILL RE-EXAMINE AT NEXT ❑ LSO NOT CONCEAL UNTIL REINSPECTION INSPECTION COMMENTS: (for inspector use only) i L(c Inspector �' � � � .Data• / �— ` OL/ Municipality of Anchorage Department of Health and Human Services 825 OV Street P.O. Box 196650 Anchorage, Alaska 995IM5o Rick Mystrom httpl/www.d.arichorage.ak.us Mayor Permit Number. #SW 030484 Date of Issue:11 19-03 Parcel Identification Number. 017-112-37 Date Started: 6-9-04 Date Completed: 9-10-04 Is well located at approved permit location? ® Yes ❑ No Legal Description: Pollock Homestead Block B Lot 11 Property Owner Name &Address: Ryan Mathias 13120 Lupine Road Anchorage. Alaska 99516 Borehole Data: Soil Type, Thickness do Water Strata Stick up -gravelly silt - Bedrock Depth (ft) Method of Drilling ® air rotary ❑ cable tool From To Casing type: steel 0 2 Wall Thickness: ,250 inches 2 36 --Diameter: B inches Dcpth�40 feet _ 36 491 Liner Type: Diameter: inches Depth: feet Casing stickup above ground:,? feet Static water level (from ground level): 30 feet Pumping level: 491 feet after 2-4 hours pumping 5 gpm Recovery Rate: 5 gpm Method of Testing: Atlift Weil Intake Opening Type: ❑ Open End ❑ Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: hLnjonjje.L8 Volume: Depth: Start 0 feet Stopped 10+ feet Pump: Intake Depth feet PUMD size hp Brand Natne Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: chlorine table1S Comments: Well Driller. Alpine Drilling B Enterprises PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to thero Owner ` J= •, - �.... LL . T. p petty within 30 days of completion and the property 1 G16q- MUNICIPALITYOFANCHORAGE Development Services Department 1 V On -Site Water d Wastewater Program ^ m 4700 South Bragaw Street t1✓ P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 l _ ON-SITE WASTEWATER DISPOSAL SYSTEM ) WATER SUPPLY PERMIT Initial Date Issued: Nov 19, 2003 Permit Number: SW030484 Expiration Date: Nov 18, 2004 Parcel ID: 017-112-37 Legal Description; Pollock Homestead Block B Lot I I I Design Engineer: 0041 AK Water & Wastewater Consultant Site Address: Unknown Owner Name: Ryan Mathias Lot Size: 20312 SO. FT. Owner Address: 13120 Lupine Road Total Bedrooms: 4 Permit Bedrooms: 4 Anchorage . AK 99516 - This permit is for the construction of. ❑,/ Disposal Field [?] Septic Tank E] Holding Tank [3 Privy Q✓ Private Well E] Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By. Issued By. Date: Date: i' �% Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. �,1' Z 1 Permit Number Sw0YQ 8'¢ Property owners) RYAN MATHIAS Day phone 240-8430 Mailing address (1) 13120 LUPINE ROAD • ANCHORAGE. AK Mailing address (2) Zip Code 99516 Legal description (Lot, Block & Sub'd.) LOT 11, BLOCK B: POLLOCK HOMESTEAD SBDIVISION Legal description (Section, Township & Range) N/A Lot Size 10 1 14 Z Acre Sq.Ft THIS APPLICATION IS FOR: Number of Bedrooms 4 Sewer Only ❑ Well Only ❑ Sewer and Well 0 Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. ALASKA WATER & WASTEWATER CONSULTANTS, INC. Permit Fees: t <; (�—O Waiver Fees* Date of Payment 1 � L /Date of Payment u1111 i Receipt Number. I `1�'_ Receipt Number., ALASKA WATER F& WASTEWATER CONSULTANTS, INC. November 10, 2003 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 Ref: Proposed Well and Septic System for Lot 11, Block B; Pollock Homestead Subdivision ADVANTEXT"t TREATMENT SYSTEM To whom it may concern: 1. GENERAL: The proposed 4 bedroom home will be served by a private well and septic system. Three test holes were excavated on the property. We are proposing to design the septic system around the 30 foot radii of test hole #1 & #3. Due to the limited amount of receiving soils and high groundwater we are proposing to use an Advantex treatment system with a pump vault and a pressurized 5 -wide trench type drainfield. The well is to be located in the area shown on the site plan and design drawing. 2. SOILS: See the attached log, which shows the soil classifications, groundwater monitoring, and the percolation test results. 3. DRAINFIELD APPLICATION RATE: The intent is to install an Advantex Treatment System that will allow the use of a small drainfield in the area around the 30 foot radii of the test holes. The Advantex system has received class III approval and we are going to assume an application rate of 4.0 GPD/FT2. 4. PRESSURIZED 5 -WIDE DESIGN: a. Percolation Rate: <1 & 6.7 minutes/inch b. Proposed Application Rate: 4.0 gallons/day/tie e. Number of Bedrooms: 4 d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 150 fl2 f. Total Depth: 1.0 feet (max. limited to the removal of organics) g. M.O.A. Approved Sand Filter Depth: 2.5+ feet h. Effective Depth: 0.5 feet i. Width: 5 feet j. Minimum Length: 30 feet long k. Effective absorption area: 150 ft2 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507 Ph: (907)337-6179' Fax: (907)338-3246 0 Websitc: akwwc.com 5.ORENCO PACKAGE SYSTEM: The STEP tank with the Advantex Treatment System will be manufactured by Anchorage Tank &: Welding to meet the latest design criteria established by Orenco Systems, Inc. The point of contact at Anchorage Tank is Lowell McNutt. As with their standard STEP tank, it is equipped with a high water alarm per M.O.A requirements. 6. SURFACE NVATER: There are no surface water within 100+ feet of the proposed septic system. 7. TOPOGRAPHY: As can be seen on the attached topography site plan the area around the proposed drainfield is relatively flat. In short, there are no slope concerns. 8. CLOSING: I am open to any suggestions from your department that would be an improvement to the proposed system. I am unaware of any negative impacts that this installation would impose on adjacent wells, or septic systems. If you have any questions, please call us at 337-6179. I n P.E.1 M.S. NOTE: Attached is a site plan drawing, a design drawing, an Advantex detail, a trench detail, three soil logs, and a 7 page construction specification letter which are all part of the design package for this septic system. 3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507 Ph: (907)337-6179' Fax: (907)338-3246' Websitc: akwwc.com I LOT 6, BLOCK B � / I\\PpLLOCK HOMESTEAD S/D 1 I / I // • 1 1 �F''— LOT -9. BLOCK B 1 / POLLOCK HOM STEAD I � `-SEPTIC\ I j 1 I LOT 4, BLOCK A'' JJ �+ LOT 3, BLOCK A I I� POLLOCK HOMESIF��I ���` ��\\ I y1pLDINO POLLOCK HOMESTEAD i I I �\`_--- • �\ \j PROPOSED AN lc�PTIC 4 BEDROOM /A,R� 1 / i I ,nn• wF11 aATnlsJl HOUSE I \ WW ALTERNATE SPIE ice, 1 I�EPTIC i \\ I ARS 1 \ �� \ n+J3 i� LOT 3, BLOCK 2 �\ LOT 2, BLOCK A I / \\ FYI ' �� PoLLOCK HOMESTEAD \ POLLOCK HOMESTEAD I L04 S, BLOCK A PoLLOCK HOMESTEAD y ABANDONED TH/WI �THJp I WELL TMJ PROPOSED SEPTIC SYSTEM I \\ I TMJ --__ (SEE DESIGN PACE 2 OF 4) I \� • i - -'E-- EXISTIG LOT 1, BLOCK A I ��-� bG `� CLASS NC- POLLOCK HOMESTEAD I I LOT 6, BLOCK A WELL i I POLLOCK HOMESTEAD ' 12 I ALTERNATE SITE I `�VACANT� I I►�PIl 1 \ / ws�4�- PROPOSED _�'- / �� 4 BEDROOM HOUSE RABBIT CREEK ROAD__ `" -------- � PROPOSED WELL LOT 1A, BLOCK 1 POLLOCK HOMESTEAD LOT 18, BLOCK 1 POLLOCK HOMESTEAD LOT 2. BLOCK 1 POLLOCK HOMESTEAD 11/10/2003 •_. OF �• i t/ �. _ DRAWN BY: ��>�� •� +)��il ALASKA NVATKR & «'ASTBNVATKRJ.L.M. :`c., '4 S7*' CONSULTANTS, INC. 5 ..... ..... ... ...... H F TUDOR ROAD. SIIITF 101 • AWAGF. AR 99507 • FNONF (907)331-6179 • FAX (9W153A•3746 1 — loo, i .PARED FOR PHONE NUMBER: PAGE NUMBER: RYAN MATHIAS 240-8430 1 OF 4 i• If me s. AL DESCRIPTION: ++��r D • 79553 LOTS 10 AND 11, BLOCK B; POLLOCK HOMESTEAD SUBDIVISION +;4,1 'E OF WORK:1+)+;is�..�o TQ99i0n-�'�+ SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEM LOCATION PROPOSED GRAINFIELD. EXCAVATE A TRENCH THAT IS 1 FEET DEEP MAXIMUM BY 5 FEET WIDE BY 30 FEET LONG. REMOVE ALL ORGANICS THEN ADD 2.5♦ FEET OF M.OA APPROVED SAND FILTER AND THEN ADD 0.5 FEET OF CLEAN, WASHED SEWER DRAINROCK. THE OISTRIBUTIOIN LINE IS TO BE 1.25 INCH PVC PIPE WITH 1/4 INCH HOLES DRILLED EVERY 10 INCHES ON CENTER, 30 HOLES TOTAL (SEE DETAIL DRAWING, PACE 4 OF 4) / THl3 PROPOSED 1500 (SEGALLON ADVANTEX /SYSTEM.t/\——t ED AI DRAWIING+rtPAGE 3 OF 4.) r——oral MNJL------J II -STALL �J FOUNDATION T(!1t, rl I RABBIT CREEK ROA PROPOSED 4 BEDROOM HOUSE TH/2'I'{� AND EAST LOT LINES FLAGGED BY A REGISTEF LAND SURVEYOR PRIOR TO CONSTRUCTION. / 11/10/20 DRAWN BY: ALASKA WATER & WASTE RTATER J.L.M. CONSULTANTS, INC. I SCALE: 1" = 307 3701 F. TLOOR ROAD. SIIITF IOi • ANGNORAGF. Ac 00507 • PHONF (007)337--70 • FAX (007)33A-3746 PREPARED FOR: PHONE NUMBER: PACE NUMBER: RYAN MATHIAS (907) 240-8430 2 OF 4 LEGAL DESCRIPTION: POLLOCK HOMESTEAD SUBDIVISION; LOT 11. BLOCK B TYPE OF WORK: DESIGN OF PROPOSED WELL LOCATION AND SEPTIC SYSTEM i'� SITE 1/C�-7Q-93 k) NOTE: JIM CROSS, P.E. HAS THE AwANra MANUAL AdvanTe)( Treatment System AX20 -Mode 1a _ _ _ _ 40x94Pod =� 41016 a1i • �1 UFT NOTE: THE BOARD INSULATION TO BE INSTALLED OVER THE SEPTIC TANK & 4• BEYOND ON ALL SIDES EXCEPT UNDER THE ADVANTEX FILTER. THIS WILL ALLOW FOR HEAT TO ESCAPE FROM TANK k RISE TO THE FILTER ABOVE IT. 6• dM CAP FINAL GRADE (TYP-2) 6' Pvc i 6• PVC CLUED INWAAAKC mmm TO PROPOSED DRAINFIELD b NCH IIIS"TED 1WMBeSE INLET_�j 4� ! ORENCO ----------------- --- BIOTUBE PTIONA I SCREENED VAULT SLIDE SECTION OF 6• PIPE OVER THIS CONNECTION .. PROWDE 4 BEDROOM SHEER PRROOTECTION- EXTEND TO FIBERGLASS TANK : j E�FFElL1EONT PUMP ORRICE EXCAVATION �I II i - DATE: 11/10/2003 DRAWN BY: -- -- , ALASKA NATER & WASTEWATER J.L.M. SCALE: N.T.S. CONSULTANTS, INC. 5701 E )UDM ROAD. SIPTE 10- • ANCNMAOF. AK 00507 • PMNF (901)137-61M •FAX (00))318-3)46 p 4 .. . ............. �-' •' • TM Q PREPARED FOR: PHONE NUMBER: PAGE NUMBER: RYAN MATHIAS (907) 240-8430 3 OF 4 Q P .,. If y mess LEGAL DESCRIPTION: Q�O J CE -7953 POLLOCK HOMESTEAD SUBDIVISION; LOT 11, BLOCK B N�ro feeelooc�o TYPE OF WORK: DETAIL DRAWING OF ADVANTEX TREATMENT UNIT O000 30 FEET LONG-� r------------- -----------------------�1 I MT O I' SIJ S FEET WIDE L OMT_ _- -- I -------------rr =— J -jj- INSTALL VISOUEEN BARRIER AROUND PERIMETER OF TREN( INSTALL BRACING AND STAKING AS NEEDED - ORIGINAL V DEEP MAXIMUM (REMOVE ALL ORGANICS) FROM PUMP VAULT -THE DISTRIBUTION LINE IS TO BE 1.25 INCH SCH 40 PVC WITH 1/4 INCH HOLES FACING DOWN EVERY 10 INCHES ON CENTER (30 HOLES TOTAL). AL GRADE INSULATION —FILTER FABRIC 2.5+' -FEET `OF A.OA.`" . ,. •APPROVED SAND FILTER' FEET FEET OF EFFECTIVE AS GRADE -THE DISTRIBUTION LINE IS TO BE 1.23 INCH SCH. 40 PVC WITH j INCH DIAMETER HOLES SPACED 10 INCHES ON CENTER. 11/10/2003 DRAWN BY: ALASKA WATER & WASTLRTATKR SCALE. J.L.M. CONSULTANTS, INC. 3701 F TI1D0 POAD. SUITE 101 • ANCNORAC.F. Arc 99507 • PNONF (907)357- 179 • FAX (907)33.3746 N.T.S. IREPARED FOR: PHONE NUMBER: PAGE NUMBER: RYAN MATHIAS 240-8430 4 OF 4 .EGAL DESCRIPTION: POLLOCK HOMESTEAD SUBDIVISION; LOT 11. BLOCK B WE OF WORK: DETAIL DRAWING OF PRESSURIZED TRENCH mvF n 5'-7- _ o 0 5'-3' 6/21/2002 74' 4/29/2003 -_ _,_ -,..4....... ALASKA – VVA a'�R R SVASTE«'ATKR 2 101 • NIC110R1GC. M 99507 • P1 L- 907W7-6179 • rM: 901 336-3246 • wmsOC M..a 30 3701 L TUDOR ROAD. SUITE 3 SOIL FO—G— PERCOLATION TEST 000 '. LEGAL DESCRIPTION: POLLOCK HOMESTEAD SUBDIVISION: LOT 11, BLOCK B f1 A. es5.- O 4 RICK RIDS 6/12/2002 �04� '•. C 7953 ;'`1� PERFORMED FOR: DATE: ' DEPTH (1ee1) 5 0 °.° • ..... �o°v 44��40efesslo o – 6' – TEST HOLE 1 6 1:42 ORGANICS 1 1 2' 4 1 2' SOIL CLASSIFICATIONS I y z GM/SM o;°:o> GW = ORG 3 iT1 ` L LOT 10, BLOCK 8 : 7Z•c GP ML POLLOOCK HOMESTEAD I i SM°IU GM CIL of 4-1 GC OL �'>�"• • GP GRAVEL .> o SW MH cYil ' 5 .. LENSE , .. SP CH �j' ! SM OH a� 6 SC GM 7 DEPTH TO DATE i 42 '1 I� 8 B.o.u. 9 SITE PLAN I 1"-100' 10 DATE READING CLOCK NET TIME WATER LEVEL NET DROP 11 12 13 14 15 16 17 18 PERCOLATION RATE 6.7 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 TEST RUN BETWEEN 1.5 FT. AND 2.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: ZACHARIAH CALL COMMENTS: 'TEST HOLE DRY ON 10/17/2003 AND ON 10/31/2003. 1 A.W.W.C., INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W SA1 P�� FORMED IN ACCORDANCE PERFORMED BY WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: _ H o GROUNDWATER 5'-7- s/tz/zooz 5'-3' 6/21/2002 74' 4/29/2003 •66' 5/6/2003 TIME (MINUTES) READING (INCHES) 6/13/2002 1 12:12 – 6� – 2 12:42 30 1 1 2' 4 1 2' 3 12:42 – 6' – 4 t:12 30 1 1 2' 4 1 2' 5 1:12 – 6' – 6 1:42 30 1 1 2' 4 1 2' ALASKA NVAT.KR & WASTENVATKR CONSULTANTS, INC. 1 L TWOR ftZ. SUfft 101 • AW.HOPAOL AC 09507 - PHOW-- (907)337-6172• N- (907)3w-32" • W03smek..c.w.n SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: POLLOCK HOMESTEAD SUBDMSION; LOT 11, BLOCK 8 OQ •'.J a Go e55., PERFORMED FOR: RICK RIOS DATE: 6/12/2002 OQ� i —79 DEPTHQOQ°Ov Pio 1 e ee;0�edoc (fee ) ORGANICS TEST HOLE #2 �00000�� 1 1 1 1 1 1 1 1 1 DEPTH TO GROUNDWATER DATE DRY - 9'-3- 6/21/2002 33- uawi 11' Nir I''1'�'II ���// 2 �y ;17YYSi WIN WON&, 4 3/4" DEPTH TO GROUNDWATER DATE DRY 6/12/2002 9'-3- 6/21/2002 33- 4/29/2003 11' 0/31/200 1,1 I LOT 10, BLOCK 8 � POLLOCK HOMESTEAD / TH 3 0 / 1 1 1 1 � SITE PLAN 1-.100' DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 6/13/2002 1 12:13 — 6- — 2 12:43 30 4 3/4" 1 1/4- 3 12:43 — 6- — 4 1:13 30 5- 1- 5 1:13 — 6- — 6 1:43 30 5- 1- 19 PERCOLATION RATE 30 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 5.0 FT. AND 6.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: ZACHARIAH GALL PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WA P RFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: u ALASKA «'ATLR & A'VASTK«'ATKR CONSULTANTS. INC. 4.;... ,•• .L .��.... ...: O 1JUIL LUU — rLKL:UL.AIIUN ItJIIQ��. G LEGAL DESCRIPTION: POLLOCK HOMESTEAD SUBDIVISION; LOT 11, BLOCK B. OO •p '.J 6Off1 ss.• PERFORMED FOR: MATT LEDERHOSS DATE: 4/29/2003 QO 953 DEPTH ____ (feet) === :ORGANICS TEST HOLE 3 4����0000���00 7 8 9 10 11 12 13 14 15 16 17 DEPTH TO GROUNDWATER • ° o SOIL CLASSIFICATIONS 4/29/2003 2 .00° 5.0' 10/17/03 5.0' 0:°°o 0 SP/SW GW --- ORG 2.5 FT. �•°°°o •� °°o° n .:+s% GP I ML 3 .:.°e°° SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: SUSAN 6 — 4 0' 6' e°o° 1 W GM CL •o.°o •' TH 3 CERTIFY THAT THIS 4 • 4° GC OL 0' 6' /� /o O SW TH/1 — — MH 5 '• • t SP CH I • SM OH IL 6 SC 7 8 9 10 11 12 13 14 15 16 17 DEPTH TO GROUNDWATER DATE 5.0' 4/29/2003 37' 5/6/2003 5.0' 10/17/03 5.0' 10/31/03 DATE READING CLOCK NET TIME TIME (MINUTES) WATER LEVEL NET DROP READING (INCHES) 4/29/03 1 — — ` LOT 10, BLOCK B 2 — 4 0' 6' POLLOCK HOMESTEAD i 2.5 FT. 4 — 4 0' 6' A FOUR HOUR PRESOAK WAS PERFORMED: 5 — — 6' — SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: SUSAN 6 — 4 0' 6' UI I, 6' — 8 — 4 TH 3 CERTIFY THAT THIS 9 — — 6' — 0 a, i i 0' 6' /� /o O TH/1 — — 1 THT I IL I � SITE PLAN 1"-100' DATE READING CLOCK NET TIME TIME (MINUTES) WATER LEVEL NET DROP READING (INCHES) 4/29/03 1 — — 6' — 6 (INCHES) 2 — 4 0' 6' 3 — — 6' — 2.5 FT. 4 — 4 0' 6' A FOUR HOUR PRESOAK WAS PERFORMED: 5 — — 6' — SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: SUSAN 6 — 4 0' 6' 7 — — 6' — 8 — 4 0' 6- CERTIFY THAT THIS 9 — — 6' — WITH ALL STATE AND MUNICIPAL 10 — 4 0' 6' /� /o O 19 I I PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 1.5 FT. AND 2.5 FT. 20 _fly—JII A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES N NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: SUSAN OSWALT COMMENTS: PERFORMED BY AKWWC, INC. 1, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PE FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: /� /o O Municipality of Anchorage .41 4111 On -Site Water & Wastewater Program I se in-'—�` ;LLQ(907) 343-7904 OEC 6 2013 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 017-112-37 Expiration Date: J `� 1. GENERAL INFORMATION Complete legal description POLLOCK HOMESTEAD; BLOCK B, LOT 11 Location (site address) Current Property owner(s) Mailing address Real Estate Agent 2. TYPE OF DWELLING: 15340 POLLOCK DRIVE, ANCHORAGE, AK, 99516 JONATHON & MINDI SINCLAIR Day phone 15340 POLLOCK DRIVE, ANCHORAGE, AK, 99516 762-4603 HEATHER DAMASSIOTIS W/ KELLER WILLIAMS Day phone 865-6433 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well E Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ I Waiver Fee $ Date of Payment �� �21�� Date of Payment Receipt Number 6(..%(o rn Receipt Number COSA# C�J�1�Ji��J� Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK, 99507 Engineer's Printed Name Engineers Comments: JEFFREY A. GARNESS, P.E. In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADES and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE System #1 Approved for System #2 Approved for Disapproved. Conditional approval for bedrooms. bedrooms. bedrooms, with the following 337-6179 Date C-ZjN o ® , • iffAm VCE -795) i 21J�` .1sT o Er. ; Pro f e ssio�000 Y tOF Wo f/, tic ON-SITE WATER AND WASTEWATER �.� PROGRAM Original Certificate Date: The Munfc6Yty 6r rage Develop, emt Services Division (DSD) issues Certifibates of On -Site Systems Approval (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory ra<„ vnsi Nitrate Advisory Arsenic Advisory Other If more than 1 septic system is on the lot: COSA Checklist # Of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: POLLOCK HOMESTEAD; BLOCK B, LOT 11 Parcel ID: 017-112-37 A. WELL DATA *BEDROCK ® 36 Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed 6/9/2004 Sanitary seal (Y/N) YES Total depth 491 ft. Cased to *40 ft. FROM WELL LOG Date of test 6/9/2004 Static water level 30 ft. Well Log (Y/N) YES Wires properly protected (Y/N) YES Casing height (above ground) 16+ in. AT INSPECTION 11/22/2013 Well production 0.5 g,p,m, 1.01 g.p,m, WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Nitrate /'J(:) mg./L. Collected by: GEG, Ltd. Arsenic: N Q ug./L. Date of sample: 11/22/2013 B. SEPTIC/HOLDING TANK DATA Tank Type/Material S.T.E.P./STEEL Tank size 1500 gal. Number of Compartments 2 Date installed 1/5/2004 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (YIN) NO High water alarm (Y/N) YES Date of pumping 5Cc i.n50a,e , Pumper A+ HOME SERVICES C. ABSORPTION FIELD DATA BELOW EXISTING GRADE Date installed 1/5/2009 Soil rating .p.d./ or ft/bdrm) 4_0 System type TRENCH Length 30 ft. Width 5 ft. Gravel below pipe 0.6 ft. Total depth *3.2-3.9 ft. Eff. absorption area 150 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 11/22/2013 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test DRY in. Water added 625 gal. New depth DRY in. Elapsed Time: min. Final fluid depth DRY in. Absorption rate >= 600+ g,p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date NOTE: TRENCH WAS INSULATED. 24" SOIL COVER SATISFIED. D. LIFT STATION Date installed 1/5/2004 TIMER/ "Pump on" level at 13.5 in. BOTTOM OF TANK/ Datum BOTTOM OF BASKET E. SEPARATION DISTANCES *SEE ATTACHED MAINTENANCE INSPECTION REPORT. Size in gallons 1500/76 Manhole/Access (Y/N) YES TIMER/ 46/ "Pump off' level at 13.5 in. High water alarm level at 24 in. Cycles tested * Meets alarm & circuit requirements? YES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer /septic service line 25'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain 50'+ Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printedame JEFFREY A. GARNESS Date t', -/y %l3 (Rev. 11105) of CE- 4z,fk. �3l, prof From:ANCH TANK & WELDING INC 05/20/2013 07:42 3686770 277 3715 APLUS 12/03/2013 13:39 #773 P.001/001 PAGE 05 206 456 pass ■■ ■ ■ ON ■ a ■■■ s ■moss■■ ■ s■s■■ pyre on ■ ■ MEN ■ ■ ■ ■ 11 ■■s■ rI■ A son 5 0 on No solos man saw Q Wdvan:7exo Field Maintenance Report gnchorage7ank AnnI inI Incnectinn 907-272-3543 pmpeny pwiwr/naekinp a• Discharge Amps Rlsar/Lid ...... ............... r� Sinclair K Mike Blakeslee =Jon ❑YasKN. SHs Mdreo previous cdnact Phone 15340 Pollack Drive, Anchorage AK 99516 - Blatuber Filter .... .."'-_I..... 907-555-5555 Ax Site IDs Coupe m S Pod ft AW ANL a Asia of Inst Impaction AX -103943 SW030484 202555 RTU102416 06/17/2012 Retrieve O&M Into Dally flow eecim ratio Timer settinge: Perform Field Sampling/Observations NTU US t N�TyUs) pH (6.81 DO (2 5-6, �. ; 1p pour of Sample Typical rzyaty ❑Bar1M ❑Moldy Non -typical I❑SuKde ❑aebbaga ❑Decav oilyforninlevu ❑YAS Fasrp In tank ❑ Yes Check Central Panel neclm AMPS Discharge Amps Rlsar/Lid ...... ............... r� Audible and visual alarms K Dial tone geleTtOry only ❑YasKN. Inapect/Clean Pump System Clean Measure Sludge/Scum studies I St 0ompeont/r ]Aspect Rlsar/Lid ...... ............... r� Splice Box ..................... 2nd Cumpareht Float Cord6................... ist Rome..................... previous Pump ........................ near/Lid lsyl Blatuber Filter .... .."'-_I..... Spice Box moi_ Bictube Pump Vault ... . ...... . Recimulating Splitter Valve....... Clean Measure Sludge/Scum studies I St 0ompeont/r Current Previous Currant Previous 2nd Cumpareht Current P'revluva Current previous Inspect/Clean AdvanTex Filter Inspect Clron rmal Odor.E-0in ..gent Biomet: Arms/ Exoasalw eddging/Ponding:1nor Bzceselve Inspect/Clean Discharge Pump System Inysp�ect near/Lid lsyl Spice Box moi_ FIOat cords Inspect Clron tLatamis70dfloes Pod Bottom Intake Vent Impact Clan Floats -Fir K - Pump. f. -Zi k Inspect/Service other System Components Inspect Clean Inspect Clean plolntection Equipment [I ❑ Olapaotal Latemle/Drlacae ❑ ❑ Obseivallona Additional Services, Rendered ❑ Cleaned textile sheets? ❑ Rapieoed UV items? ❑ Reploeed/Uaed other items? Parts Used: W = Warranty, B = Billable (,/ appropriate selection) W B /tam Number Doscrlptlon Final/Safety Insdoection �0RSv reinstalled rLlds boned on � ManHeld reconnected; flush valves closed klto,it.l PAPA] reactivated Summary/Re commendatlona X_-qystam performing; no further Action needed E)lank needs pumping ❑ call for seNiae ❑ Other? Fax completed form to 1.866-584.7404 ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT BETWEEN MUNICIPALITY OF ANCHORAGE AND Quce W (i� r THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this Day of �of 20, by and between herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Maintenance and Repair Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as located at (legal description). 2. Definitions. Alteration. Any change to the design or function of an AWWTS that includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Certificate of On -Site Systems Approval (COSA). An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with Anchorage Municipal Code (hereinafter, "AMC") 15.65. These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. Permit. An On -Site Wastewater Disposal Permit as required by AMC 15.65 to construct and operate an AWWTS. 3. Term. The term of this Maintenance and Repair Agreement shall begin on the date of approval by the Municipality to operate the installed system or issuance of a COSA, and shall continue while the AWWTS is in use or is operational or until the property is sold or title is transferred by the owner and a new COSA is issued to the new owner or transferee of the property. 4. Alterations, Installation and Removal of Additional Equipment. Prior to performing any alterations to an AWWTS, the owner agrees to obtain an On-site Wastewater Disposal Permit from the Municipality in accordance with AMC 15.65. 5. Maintenance and Repairs. A. Throughout the term of this Maintenance and Repair Agreement, the Owner shall maintain their AWWTS in a satisfactory condition capable of producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. The owner shall enter into a service aereement with an AWWTS service and maintenance provider approved by the municipality and the manufacturer of the AWWTS for the entire term of the AWWTS In addition, it shall be the responsibility of the Owner during the term of this Maintenance and Repair Agreement, and any renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (5) inspection costs. B. Owner agrees to comply with all applicable ordinance, laws, regulations, rules and orders for the AWWTS. C. Upon request by the Municipality, the owner agrees to provide the Municipality a written schedule of routine maintenance and repairs which have been performed on the system. When a record of maintenance is documented and maintained by the system vendor, the owner agrees to allow the Municipality access to this information. D. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60 for improper discharge. E. Owner agrees that only maintenance and repair personnel approved by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. F. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS upon 24 hours written notice. G. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. H. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. 6. Nonwaiver. The failure of either parry at any time to enforce a provision of this Maintenance and Repair Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Maintenance and Repair Agreement or any part hereof, or the right of such party thereafter to enforce each and every provision hereof. 7. Amendment. A. This Maintenance and Repair Agreement shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality that this Maintenance and Repair Agreement was executed with, and such writing shall be attached to this Maintenance and Repair Agreement as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this agreement, the only authorized representatives of the parties are: a. Owner: b. Municif C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 8. Jurisdiction: Choice of Law. Any civil action arising from this Maintenance and Repair Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Maintenance and Repair Agreement. 9. Severability. Any provisions of this Maintenance and Repair Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Maintenance and Repair Agreement. OWNER: 1` By: LLC L (signature) Date: r (print name) STATE OF ALASKA ) ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this 11, day of 20a, by 10,� r NOTARY P IC MRALASKA My Commission expires:: '1 �,- MUNICIPALITY: name) Date: Title: Municipality of Anchorage Development Services Department :• - p Building Safety Division On -Site Water t: Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519.6650 www.muni.org/onsite P (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING nr1 ,1 Parcell.D. (��}–I��–�� COSA# l)o?s1� may_ 1. GENERAL INFORMATION Expiration Date:—/ I –1 Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address POLLOCK HOMESTEAD: BLOCK B. LOT 11_ 15340 POLLOCK DRIVE *ANCHORAGE, AK 99516 CHUCK & CHRISTY CLEMENT Day phone 360-2715 15340 POLLOCK DRIVE *ANCHORAGE AK 99516 Day phone TAMI TAYLOR W/ PRUDENTIAL Day phone 244-3504 3801 CENTERPOINT DR 11200 *ANCHORAGE -AK 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well N Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site 0 Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Finn GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD. SUITE 101 • ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date 135 OS Engineers Comments: In conducting this evaluation, GEG, LID. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines 8 Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden detects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE ✓ Approved for __q_ bedrooms. Disapproved. Conditional approval for bedrooms, with the flowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By. G(/, 8� Original Certificate Date: (R. 11105) Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST 0 T, Legal Description: POLLOCK HOMESTEAD BLOCK B, LOT 11 Parcel ID: Q%7- / /2' 37 A. WELL DATA Well type PRNATE If A, B, or C provide PWSID# N/A Date completed 6/9/04 Sanitary seal (Y/N) YES Total depth 491 ft. Cased to 40 ft. FROM WELL LOG Date of test 6/9/04 Static water level 30 ft. Well production 0.5 9.p -m. WATER SAMPLE RESULTS: Well Log (Y/N) YES Wires properly protected (Y/N) YES Casing height (above ground) 18+ in. AT INSPECTION 7/23/09 25 ft, 1.4 g.p.m. 0 Coliform 0 colonies/100 ml. Nitrate ND mg./L. Other bacteria 0 colonies/100 ml. Arsenic: ND ug./L. Date of sample: 7/23/09 Collected by: GEG Ltd. B. SEPTIC/HOLDING TANK DATA JADVANTEX SYSTEM Tank Type/Material STEP/STEEL Date installed 1/5/04 Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (YIN) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES Date of pumping 6/17/09 Pumper A+ HOME SERVICES C. ABSORPTION FIELD DATA FOELOW EXISTING GRADE Date Installed 1/5/09 Soil rating (g.p.dJft'o /bd 4_0 System type TRENCH Length 30 ft. Width 5 ft. Gravel below pipe 0.6 ft. Total depth •3.08+ ft. Eff. absorption area 150 ft' Monitoring tube YES Depression over field NO Date of adequacy test 7/23/09 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 600 gal. New depth 0 In. Elapsed Time: 0 min. Final fluid depth 0 in. • Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date — D. LIFT STATION 'INSPECTED BY A+ HOME SERVICES DURING MAINTENANCE INSPECTION Date installed 1/5/04 Size in gallons 1500/76 Manhole/Access (Y/N) YES "Pump on" level atTiMER 13.5 in. "Pump off" level at TIMER 13.5 in. High water alarm level at 46/24 in. Datum BOTTOM OF TANK Cycles tested ' Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main Sewer /septic service line 25'+ Animal containment areas 50'+ Public sewer manhole/cleanout N/A Holding tank N/A Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service tine t0'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10,+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain 50'+ Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION AF I certify that l have determined through held inspections and ........... . ............... review of Municipal records that the above systems are in Q conformance with MOA COSA guidelines in effect on this Q date.Q of r y A. Garness� Engineer's Printed Name JEFFREY A. GARNESS�Q CE -79 3 Cpl Date�'' �qoo 04°d Pro f s $slot\ ��00000�� COSAFee S L4C1b SSL Date of Payments t) Receipt Number 09 5 Y 8 3 (Rev. 11105) Waiver Fee $ Date of Payment Receipt Number 146 183 awn on on ■■a■ an ■1a■ one MR as ■o ■ a. • ■1■ ■ on ■1■ ■ ■■ ■a■ a. a. an I INS no ■ ■ on ■s am o WanTexa Field Maintenance Report AnchorageTank & Welding, Inro Unscheduled 907-272-3543 Prey O .a.m ng s Om®O®®m® OP~ . Charles & Kristy Clement Pow (Green LED) Mike Blakeslee sm Adeno Gama Peer. 15340 Pollock Drive, Anchorage AK 99516 (907) 360-2715 A%amce camry DP Pod• RfV WLP omatrlk.PMla. 103943 SW030484 202555 RTU702418 06/082009 Dispatcher Comments Data 06/102009 Time: 12:00 AM Replace discharge pump. Notification of site condition ❑ Made by VerlComms Monttorkq system ❑ Mads by Nomeowrrr ❑ Other Site condition at time of call ❑ Alarm ❑ Tank Overflow ❑ Oda ❑ Sewage Backup ❑ Outer Field SamplingfObsenations ❑Necesary ❑Not naaassry Ntu tis s NTUs) FN (6-11) 1 DO a$) Odor of Sample. typical ❑Musty ❑Earthy ❑Moldy Non -typical ❑Sulfide ❑Cabbage ❑Decay Conditions at site Alam On ❑ Yea ❑ No (ll yes alarm type ) Tank Liquid Level ❑ Normal ❑ Nigh ❑ hew Pump Operational? ❑Yu ONO Group Breakers R,dre........ ❑ Tripped ❑ On ❑ Oil Dechargs..... ❑ Tripped ❑ On ❑ Oe Controls ...... ❑ Tripped ❑ On ❑ Off VOOMs ATRTU Board: (Ir applicable) Document the panel status by shading the appropriate Inputs and outputs as indicated by the yollow and red LEDs. Inputs Om®O®®m® OwtpLft Pow (Green LED) ❑ On ❑ On ❑ Flsshkg Cause of Malfunction:❑ Modianical ❑Process -Related Part Used: W . Warranty. 8. Billable (V appropriate selection) Notes/Final Recommendations: ❑ System peaorming; no action needed ❑Additional service needed FlnaVSafety Inspection: Uds boned on7 ❑ Yes Of damaged, comment Cordml Panel reacgvated7 ❑ Yes Orcutt Breaken: ❑ No ❑ NO Realms ❑ On ❑ Oe 0isdwnw.. ❑ On ❑ of Co ,u [:)On ❑ On Time at Stta Trawl Tine Total Time signatuie I Pete Time Fax completed form to 1-866-384-7404 rav-20-2M es:39R FROM: 70:16663847404 P:616 1D1519 new ■■ ■ BEEN E on ■ ■ on E IN Muslim SEE 3 See so a man sommumm amuse to See FsW Maheam of Report Inspection Anch�geTank & Welding, Inc. 807-272-3543 rwewy dem Charlet & Krinty demand Crean ❑ 15310 PoAodc Drive, Andnwe, AK 88516 (907) 360-2715 uc ewDl Cent/ D1 rase IRU Nn.e er•.e.T am AX•103943 017-112,37 202555 R7U102418 0211612005 ttetrieve O&M lide DeN De's aecira two Tkrw -I" Redrc Ort Cycle Time-17.5hnin Rodrc on Cyde Time - O.5/min per/erm Field ■reptir■4be0r9*11" Irtu t+t a wtw pIt twt oo t: -m Dd.r N ttrea�r,s/ Typbd ll7�r ❑ter Ue�er wmopreel ❑www Ocawiw ❑Deter old eDo ti low ❑ws ❑no Foam to whet ❑w 0 ChwA cano'cit Pane: wow Amw oreceew A," 17A I N33 aodaM wrd vwd awe. ❑ox Dien I" ferern.etr-M Lbw ON. Irepeet/CI"n Pwrw Brerem Dupes ta..n IErrn.a ..................... RAN I. .................... Q9 r ........................ rd emcee. neer................. O U tFn cramp VwA ............Q� 12 R dll*AW95Ydw....... CJ Coneeerr+. Measure Skrdoa/temno let compav rent Qmet is" 1 tiw:oi` O`°'�ri PT+m plod e\ar.M rrpvDw 0"W2, Lt r� hepeet/pwn ddvanTex rMter Oaor. ❑ lL Mpee: ■an.0 r ni7aeCNe enepinyloendrq� �. ❑Da.rwa lnapectMleen Di.N,.roe Pump ■retem veodd w..riud O Mae Baa ❑ rim Dome ❑ 'tn"ed/Service Other ll/stem Cemponarw tn., I Deer Dwe com twAX ,d ❑ O arpect Crean ❑ ❑ Itauniwom,iis Pod Boom ❑ L1 Md_ RSV"10 reawwo.rd.. ar.n wvea 610"0 ���eaD.d on Wl6" lower react.eud Depwt oewr Abets O 13r.elo ❑ ❑ kwoog etre oeperatLxiww- mor. ❑ ❑ Additional Services Rendered ❑cararoe - m amen ❑nep:ac.d w Dome+ nwwaea)O.d wwAw rr+ Md_ RSV"10 reawwo.rd.. ar.n wvea 610"0 ���eaD.d on Wl6" lower react.eud Swrwnary/Itecerwnrerrdetiiene QSmm�entayusnbp.k..++g ❑Cat for Savin ro Vrewtactlon neaeearK ❑Tart naw p•eaptq LIQ S .— Date Fax completed form to 1-886-784-7404 OCT -1-2093 12:0W FROM: TO:18663847404 P:4,6 laws ■i■■ i■■i■■■■■■■■ ■ soni ■ ■■■ ■■ ■ .■■ Field Maintenance Report Inspection Charles 8 Kri* Clement 112 520 ■ ■ ■■ no ■ ■ ■ ■■■■■ � on no ■ . ■■■ ■ swes o AnchorageTank & Welding, Inc. 1 907-272-3543 3 15 0 Pollock Drive -Anchorage AK 99516 v T9 07) 360-2715 uwro. l;w.r ro. eae. rrtV.na.s h.r•w Dal. AX -103943 SW03J 84 202555 RTU102418 OS/202DC8 Retrieve 03M Info Daily low . Rrxhrc ratty _... •-- Tlm.r s rninfis: Recirc Ott Cycle Tie -17.5/min Recirc On Cycle Time - 0.5/min Perform Field Samplingl0b"mations Nru(lazNTW) pretaat DORS I ",� M..0y rUQW Non-typicel ❑suMdo ❑Cebbpe (70eeey Odoror Sample. ❑purro.rd TypiWl ❑PAVIty ",� M..0y rUQW Non-typicel ❑suMdo ❑Cebbpe (70eeey ouytumin►vu ❑Yea tRNo room In unk I.lvee ,L7.,N/c Cheek Control Panel w r near. a,ap. or.uwroa wmp• rk PAWlb& and Msuul:lama Ia1oK Dial tom (telemetry only? ?_lyes V.No Inspect/Clean Pump System krep0e, Clean 11"I/Lad ....................,�� apku Dua.................... r Fled Cane ................... F,oats........................ rump ....................... L' Las awtub0e Flta.................r l—'7•, Blolube Potts Wulf............ 1.1 FR Iledroulatep splllluflku.e....... r: canment.Q:¢I �,�� Measure Sludge/Scum Inspect/Claan Advan7ex Fitter Odor, 1 ❑purro.rd alomat lie" r-3 eesatw swonmwwh w ❑Nonan lot Cempennhenl Cuff" ►rv.bus Current w 1D rk and compare Cunwrt previous current Pre.ioua Inspect/Claan Advan7ex Fitter Odor, 1 ❑purro.rd alomat lie" r-3 eesatw swonmwwh w ❑Nonan nano "s Inspect/Clean Dlaoharife Pump System kiapx�/ 7I runler oetb.h neoeeeerY. Bpaa Boa Flow. pard: Irspoot cLle/ar) l attaal~was ❑ G ►od Soft" n E;- MaLe vont @ ❑ impact peen So= n C4l Pump II Fi?, Inspeet/Sarvke Other System Components bsped Clean knpeot dean dMamem I I L7 obpersaltabrala/Orfilm I I O Addhlo Services Rendered I leatae .hoots? O Replaced UV Mme? i other Mmol Fnattgotety Inspectionweloorw SlanatuajY- Data 9 _ Fax completed form to 1-668-384-7404 Cl uds brand en I .wnlrold mmnnecled; flush VSKw:bead ❑Coneolpu.lreaNWated Stun nary/Reoornmendatlrma l nl ey■tom is penomnk a: ❑ Ga ter Sam" 7I runler oetb.h neoeeeerY. ❑Lok rosda ph.hrWrhp SlanatuajY- Data 9 _ Fax completed form to 1-668-384-7404 JUN -8-2039 10:34a FROM: TO:186631347404 P:V6 144350 M ■,,s ■ son ■ son ■ ■ s t ■ ■ as ■ i tm as ■ an ONE s ■ as ■ ■ ■ ■ ■■ Mans ■s !■ ■■ ■,s■ ,s ■ ■■ ■s■ = p [00vanTema Rdd Maktenwce Report AnchorageTank & Welding, Ina Annual Inspection 907-272-3543 n.p•vr o,.�dr,,.a.y• cfi" a.� - - Charlea 6 Kristy Clement kM*A vwd ❑ Mike BIa*eslee armr. ��.�.. 15340 PDnodt Drive, Andmrape AK 84516 (907) 360.2715 m modO..lr Op baa• efll ati• &"er a.pwk. AX -103943 SV403 84 1=1=05 'T. Rrtr:.v. CR1N kdo '� OY111ow pAcim rale Tln.r aww'vw 1107 Perform Field SamP4r1u/Ob§uwtiery � ns a NILlq pr16-pr DD a� natal of Sable ?ypk:d ❑maty mrw" ❑Hoary wn+m" ❑Bruno. ❑cabbepe ❑Decay oer 8Bt h PYY ❑?ba war to InA, ❑?ea w No Chwck cot, I Panel F. ft Amps D-Owr a Awas /2r3 1 00.00 A MMAS"0" WMr DrQK Dw tare fto m ey vmw ret za IRspeet/Clson Pump Eystern kalpact aeon Cas-fud .................... Bolt Dar ................... F" cora ................. Itbat....................... pol A ......................... S&C40 a I3rr................. W�. Mot "Vardt ............ 1 coma+ama _�. v iSCharq C( Measure SbAdye/6eum BInrdee Saw Calf Cpmpartntwrt // Prow(ka C rmm pmol u. 2MCamprM.nr t?..d p I"a :: v erb�e MapeoVCtean A&MTet FDter Dda. IKNwmY ❑prar0.nt ekwAt KNama1 ❑•--�- BM0kv (dkv wNonaMhn ❑zsowu kmPect/Cleen Dischrye Pump System Inspect ntaarnad I$ Boaoe Baa Find Dada hISDOWSerrlu Duren Syetam Components bapect twarbar 4r>fi cfi" Pod Basan n kM*A vwd ❑ ❑ rt r Irmpom awn ksp«l aawr —% Dct-Eq*mem ❑ ❑ Dlapasal Lewwaormaee ❑ ❑ ob"Na"we Additional sonic" Rendered Ackwr.d 6,Xft w aft? ❑ PAMCed W ltar.? ❑PA%w d.U..d ac e. Bens? Parts Used: w. Warranty! 8. Salable I: eppropWe vw1w rel "=,et ,mpectien .trbrw tlda bothd an Ix maNtald bca wa.4 a .h wan eleaed eopbol pww Rac"Vew Sum ma ryM Boom m endauo ns 06yctwe perlomir¢np ft~ .cWnereded KTAM n..- wm*v �vuyr� Dna �i—Y, B;t,�Yb• �iHti ar ftn+J ICM biwe n Fax Completed form to 1-866.384-7404 (cD�� 400% Municipality of Anchorage 0 Development Services Department '.,.. ., Building Safety Division ' On -Site Water 8 Wastewater Program ❑ 4700 South Bragaw St. ❑ P.O. Box 196650 Anchorage. AK 99519.6650 ❑ www.ci.enchorage.ak.us ❑ (907)343-7904 ❑ CERTIFICATE OF HEALTH AUTHORITY APPROVAL A FOR A SINGLE FAMILY DWELLING Parcel I.D. 017-112-37' HAA# 194 OUI(o 1. GENERAL INFORMATION Expiration Date: / 1—.2 3 Complete legal description Location (site address or directi Current Property owner(s) RYAN MATHIAS Day phone 240-8430 Mailing address 13120 LUPINE ROAD • ANCHORAGE. AK. 99516 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given In paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the onsite water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. 1 further verify that based on the Information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the on-site water supply and/or wastewater disposal system Ware) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Finn GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SURE 101 • ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineers Comments: In conducting this evaluation, GEG, Ltd. attempted to provide a thorough, conscientious engineering analysis of the system In accordance with ADEC and MOA DSD Guidelines 6 Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily Identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, Ltd. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will It confer any legal right whatsoever. 5. DSD SIGNATURE Approved for bedrooms. Phone 337-6179 Date 13 Z3 nt Disapproved. R Conditional approval for 4 bedrooms, with the filowing stipulations: At the time of title transfer the new property Pr ah ll Aign rh fir shad maintenance agreement which shall he rPtvrnPd fin rhi ff"oh Fora ^ Attachments: HAA Checklist Septic System Advisory Well Flow Advisory 1/ Manitenance Agreements Supplemental Engineers Reort Other Original Certificate Date: 42' 3-0 tI- By: (Rw. 11/01) Municipality of Anchorage ' Development Services Department Building Safety Division Onsite Water & Wastewater Program 4700 South Bragaw, St. P.O. Box 196650 Anchorage, AK 995196650 www.d.anchorage.ek.us (907) 343.7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Desariptlon:POLLOCK HOMESTEAD SUBDIVISION* LOT 11. BLOCK B. Parcel ID: 017-112-37 A. WELL DATA *CASED TO BEDROCK Well type MOTE If A, B, or C provide PWSID# N/A Date completed 6/9/2004 Sanitary seal (YM) YES Total depth 491 ft. Cased to •36 ft. FROM WELL LOG Date of test 6/9/2004 Static water level 30 ft. Well production •5 — g -p.m - WATER SAMPLE RESULTS: Well Log (Y/N) YES Wires properly protected (Y/N) YES Casing height (above ground) 16+ in. AT INSPECTION ft. g.p.m. Coliform 0 oolonies/100 ml. Nitrate 0.1 mgA. Other bacteria 1 colonies/100 ml. Arsenic: N/A mgA. Date of sample: 8/2/2004 Collected by: GEG. LtD. B. SEPTICIHOLDING TANK DATA Tank Type/Material STEEL Date installed 1/5/2004 Tank sae 1500 gal. Number of Compartments 2 Cteanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES Data of pumping NEW Pumper — C. ABSORPTION FIELD DATA Date Installed 1/s/2004 Soil rating .p.d r ft1bbdrn) 4_0 Length 30 ft. Wkfth 5 ft. System type TRENCH Gravel below pipe O.6 ft. Total depth •3.04 ft. Eft. absorption area 150 ft' Monitoring tube YES Depression over field NO Date of adequacy test — Results (Pass/Fall) — For 4 roorTC Fluid depth in absorption field before test = in,—...T17kA New depth =in. Elapsed Time: = min. kr. Absorption rate > — g.p.d. (past 12 mo.) (YIN & type) — If yes, give date — D. LIFT STATION Date installed 1/5/2004 TIMER/ "Pump on' level at 13.5 in. Datum B.O.H. E. SEPARATION DISTANCES Size in gallons 1500/76 ManholelAccess (YIN) YES TIMER/46/24 in. 'Pump oft level at _ in. High water alarm level at Cycles tested NEW Meets alarm & circuit requirements? YES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAtft station on lot 100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer /septic service line 25'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water •100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water •100'+ Driveway, parking/vehide storage 10'+ Curtain drain 50'+ Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION 1 cantly that I have deterruned through Held Inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineers Printed N me JEFFREY A. GARNESS • Date fit 23 Gr}' dp�ot. HAA Fee E So } 125 � Waiver Fee $ Date of Payment Date of Payment Receipt Number o5717.1 Receipt Number (wv. taro+) 08/23/2004 11:12 9072432081 SCALE. 1 °° 30' 2 Z5 Z5 co F4 FRED WALATKA & ASSO 0 0 0 N Bre° 4-I'ZI" E 1 41,5'7- Recert $ 20-04;*! : s s o o A"UILT NO CORNERS SET THIS DATE bw w06" N0. 323" SEMENTS OF RECORD. OTHER THAN Fd o 4 -¢j KXE SHOWN THE AT ARE NOT SOHOWN HEREON, Pq 5t PAGE 01 8z 39a-/ -3- 1 hereby certify that I have performed a Mortgagees Inspection Of the folkmving described property; Lo T I BLoGK 13 Pcr—t..0ck t E-.•"rE L n• 5CG6 CIV 1610N is Anchorage Recording Precinct. Alaska. and that the inlPro ements situated thereon are within the property lines and f10 not overlap or encroach on the property lying adjacent thereto. that no •Improvements on property lying adjacent thereto r encroach on the premises In question and that there are no roadways. transmission lines or other visible easements on said Property except as Indicated hereon• Dated at Anchorage. Alaska this �0 fh day of FRED WALATKA d ASSOCIATES BE l907) 248.1686 Engineers and Surveyors