Loading...
HomeMy WebLinkAboutAUTUMN RIDGE LT 10Onsite File �^�:ii..'s #15cmO54 'Y,^. xxe` 3 MUNICIPALITY OF ANCHORAGE Development Services Department MUM On -Site Water & Wastewater Section AV F�lone: 9D7-343-7904 Wastewater Fax: 907-343-7997 PumpInstallationLod Well Drilling Peanut Number: Parcel Identification Number: 15 - t75y- -__L3 Legal Description Block Lot Pump Instal€ation Date: �_ Z Date of Issue: Property Owner Name & Address: Pump Intake Depth Below Top of Well Casing: 2i >1_ feet Pump Manufacturer's Name:A_ Pump Model: -Z f 0 V -7 Pump Size: �� hp Pitless Adapter Burial Depth:( --5— feet Pitless Adapter Manufacturer's Name: Pitless Adapter Installer: Well Disinfected Upon Co etion? des ❑ No Metbod of Disinfection: Comments: Pump Installer Name: - ANCHORAGE WELL & PUMP SERVICE 7640 King Street Company:_ Anchorage, AK 99518 PH: {907} 243-0740 Mailing Address: City: State: Zip: Attentions The pump installer shall provide a pump installation log to On-site within 30 days of purnp installation. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program, 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SWO10485 PID Number: 015-051-04 Name` MASTERPIECE HOMES Wastewater System: ® New El Upgrade Y Address: P.O. BOX 773471 EAGLE RIVER, AK 99577 ABSORPTION FIELD Phone: No. of Bedrooms: (907) 694-7320 7 ■Deep Trench ❑Shallow Trench ❑Bed ❑Mound ❑Other LEGAL DESCRIPTION Soil Rating: 1 2 Total Depth from original grade: 10 MAX GPD/Sq. Ft. Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 10 AUTUMN RIDGE 4.0 MAX. Ft. 6.0 FL Township: Range: Section: — — — FII added above original grade: Gravel length: 42/40 SEE DWG. Ft. Ft. WELL: ■ New ❑ Upgrade Gravel width: 2.5 Number of lines: 2 Distance between lines: 14.5+ Ft Ft. Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: D 3034/ F-810 PRIVATE 210 Ft. 210 Ft. 984 SQ. Ft. Driller. M—W DRILLING Date Drilled: 5 31 02 Static Water Level: 185 Installer. MASTERPIECE HOMES Date installed: 12/13-14/2001 Ft. Yeld: Pump Set At: Casing Height Above Ground: TANK 8-10 GPM UNKNOWN Ft. 2 Ft. SEPARATION DISTANCES ■ Septic ❑ Holding ❑ S.T.E.P. ❑ Other To Septic Absorption Lift Holding Public/Private Manufacturer. ANCHORAGE TANK Capacity in gallons: 2000 From Tank Field Station Tank Sewer Lines Well 100'+ 100'+ — — 25'+ Material: STEEL Number of compartments: 2 Surface Water 100'+ 100'+ — — — LIFT STATION Lot Line 5'+ 10'+ — — — Size in gallons: Manufacturer. "Pump on level at: "Pump off" at: High water alarm at: Foundation 5'+ 10'+ — — — Pump Make odel: Electrical Inspections performed by: Curtain Drain NONE KNOWN BENCH MARK Remarks: Location and Description: TOP OF CONCRETE SLAB @ BASEMENT DOOR Assumed Elevation: 123.82 F, ENGINEER'S SEAL oa 'T Inspections performed by: AKWWC, INC. Dates: 1st 12/13/2001 gi... ..I ..... !...... D 2nd 12/14/2001 0 ......... .. .... .......� 3rd 12/14/2001 Q� .Jeff; ey A. G ne s.- Development SService5_Depa rtmye`nt Approval C 7953 ���De Reviewed and approved by: - �� Date: �D17-12 goo r...eSstaOo (Rev. 12/01) PERMIT N AS -BUILT DRAWING PARCEL ID NUMBER: SW010485 485 015-051-04 QFC'- SwlAl �" 1 -1-TES I I I NEW 1 WELL DRIVEWAY NEW 2000 CALLON I INEW \ SEPTIC TANKI 7 BEDROOM es A B \ o SCO \ W Delt � S _g DBL2 INSTALLED FLOW SPUTTER — i NEW DRAINFIELDS TH-56 TH-60 O Q TH-53Q5Os \ \ OF .Tfl-50 12 TH-51 O ' IO r �ap 1/14/2003 DRAWN 8Y. v \ r •gspo ALASKA WATER &WASTEWATER _ 40 0 C.J.G. p CONSULTANTS, INC. SCALL: H _ 6901 1309A"1309A"ROA9. SATF 7R • ANCHORAGF. AK 9950% • FHONF (907)53)-609 • FAX (907)338.3746 1 O 'REPARLD FOR PHONE NUMBER:+ACL NUMULN: Q MASTERPIECE HOMES (907) 694-7320 2 OF 3 Q v .J ( A. Go nesse _ECRL DESCRIPTION: Q ° E— AUTUMN RIDGE SUBDIVISION; LOT 107 0 Q�e ofe..... �040� tYPE OF WORK: pp d C O3 0 AS -BUILT DRAWING OF NEW WELL AND SEPTIC SYSTEM ��Op000 0\ A B I A 1 8 SITE. WILL ----- AN INNOVATIVE TYPE 1.______----' QTH-52 F---- L---------- ' STI 47.52 46.09 MTI 155.60 1 55.03ALTERNATE ST2 43.92 55.55 CO2 59.59 8290 DBL1 43.79 56.77 MT2 58.08 80.60 DBL2 43.73 57.72 CO3 72.77 68.16 FS 47.46 61.45 IAT3 73.34 69.43 C01 57.04 53.92 C04 80.42 97.26 OF .Tfl-50 12 TH-51 O ' IO r �ap 1/14/2003 DRAWN 8Y. v \ r •gspo ALASKA WATER &WASTEWATER _ 40 0 C.J.G. p CONSULTANTS, INC. SCALL: H _ 6901 1309A"1309A"ROA9. SATF 7R • ANCHORAGF. AK 9950% • FHONF (907)53)-609 • FAX (907)338.3746 1 O 'REPARLD FOR PHONE NUMBER:+ACL NUMULN: Q MASTERPIECE HOMES (907) 694-7320 2 OF 3 Q v .J ( A. Go nesse _ECRL DESCRIPTION: Q ° E— AUTUMN RIDGE SUBDIVISION; LOT 107 0 Q�e ofe..... �040� tYPE OF WORK: pp d C O3 0 AS -BUILT DRAWING OF NEW WELL AND SEPTIC SYSTEM ��Op000 0\ SWO10485 AS -BUILT DRAWING PARCEL015-051-04 FINAL GRADE - L 4r'ccv6J2.A TOP OF TANK STIST2 AT INLET . 105.82 TOP OF TANK nAT OUTLET . 105 82 INVERT OF BUNG AT INLET . 105.25 LOWER FINAL GRADE 100.10-101.90 NEW 2000 GALLON SEPTIC TANK FABRIC INVERT OF PIPE 95.87 (AVG.) BOTTOM OF TRENCH . 89.66 (AVG.) FINAL GRADE 104.20-105.50 12'+ 1/14/20C DRAWN BY. ALASKA WATER & WASTEWATER C.J.G. CONSULTANTS, INC. '�E' N.T.S. 6001 9FRARR FOAM SUITF 79 • ANGHORAGF. AK 995% • PNONF (907)137.609 • FAX (907)338-3766 'REPAIRED FOR: PHONE NUMBER: PAGE NUMBER: MASTERPIECE HOMES (907) 694-7320 3 OF 3 ..ECAL DESCRIPTION. AUTUMN RIDGE SUBDIVISION; LOT 10, TYPE OF WORK: PROFILE AS -BUILT DRAWING OF NEW SEPTIC SYSTEM INVERT OF BUNG AT OUTLET - 105.01 ORIGINAL GRAD 103.58 O HIGH POINT FABRIC INVERT OF PIPE 99.56 (AVG.) BOTTOM OF TRENCH . 93.58 (AVG) ON 1I I pomm ALASKA WATER & WASTEWATER CONSULTANTS, INC. July 15, 2003 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw Street Anchorage, Alaska 99519-6650 Ref: New Well & Septic System at Autumn Ridge Subdivision, L10 To whom it may concern: The installation of the subject septic system was completed in December of 2001 and May of 2002 (Well). There were deficiencies identified (see attached list) that have yet to be corrected because the builder has went out of business. The septic system was installed as per the MOA permit and all applicable codes, except that there is inadequate soil cover over the septic tank. The well location was selected by the builder and was drilled by MW Drilling. It is extremely close to the property line and it is uncertain as to whether it is on the property. In the past we requested an as -built survey that showed the well; however, the builder did not respond to our requests. We are submitting the as -built drawings of the well and septic system so that you will have them ;n vnitr nrnh;vrc please contact us at 337-6179. n.S. 3701 East Tudor Road, Suite 101 * Anchorage, AK 99507 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com ALASKA WATER & WASTEWATER CONSULTANTS, INC. •�°^°�=_^°°�°°^°°�° ^ ��_-.^^ January 14, 2003 Masterpiece Homes c/o Dynamic Properties 3111 "C" Street Anchorage, Alaska 99503 Attn: Becky Minton REFERENCE: Autumn Ridge Subdivision, Lot 10: Well and Septic System Approval Dear Masterpiece Homes, To obtain approval from the M.O.A. for an approved septic system the following will need to be completed. • An as -built showing the well location must be done. We need confirmation that the well was drilled on the property. • There is a shortage of soil coverage over the tank. There needs to be 4 feet of cover over the tank. When the following deficiencies are completed please contact us at 337-6179 6901 Debarr Road, Suite 2-B . Anchorage, Alaska 99504 Ph: (907) 337-6179 0 Fax: (907) 333-3246 " Websitc: akwwc.com M -W ®riliing, Inc. +P.O. Sox 110378•Anchoroge, AK 99511• •907-345-4000 * 907-345-3287 Fax* Job No.: 02-124 Project No.: _WA Permit No.: Groundwater Well As-Suili A Lou • Well Owner. Masterpiece Homes _ • Use of 8411: Domestic • Legal Description: Autunut Ridge Subdivision, Lot 10 Construetiot; •11oleDepth: 210' * Casing Ste: 6" •Cased To: 210' *Alarerlai. A53Steel ♦Dr!!!:flet!.ud: Air Rotary Perj. a I -e.- compie-vor.- Open end X Sereen P. crcted _ AfC.!rad: •Screen/Perforariondescrlptlon: None • Groul Notes: (1) Sack- No. B bentonite granules *lien Development: .sjethod: Airsurge Not-: *Static water level (Sli'L) 185' (ebowe) (below) top orcasing (TOC). • !Yell p/eld test at 8-10 gallons per minute (GpMYge,7onsper -hom4GNI) for I hours with Iom of drawdown(DD)fromstatl•:level(SlIT). •Alethod. Airlift ♦ Date of completion: 31 May 2002 ♦ Pump Install: Dcpth In feet from t000fcasio.. Details ofeetrated s'szeotmrterial color and hsrdness. 0 TO 2 Casin stickup 2 TO 7 To soil, fill _—__—_--._--- _ 7 TO 54 Gravel: sand '/cla •e 54 TO Gravel: wet 64 TO _64 162 Cla 'c gravel j 162 _ TO 182 Gravelly clay --� 182 TO 210 Gravel - TO --- TO TO _ TOTO ---- 10 ------ To TO —NwwA.-Certified Contractor- ---._..------_I _ _--_. Certificate No's 814 & 973 E M- � E ( A MUNICIPALITY OFANCHORAGE Development Services Department On -Site Water& Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Dec 11, 2001 Expiration Date: Dec 11, 2002 Permit Number: SWO10485 Parcel ID: 015-051-04 Legal Description: T12N R3W SEC 15 NE4 PTN Design Engineer: 0041 AK Water & Wastewater Consultan, Site Address: 005400 ABBOTT RD Owner Name: Masterpiece Homes clo Kelly Heistuman Lot Size: 2214155 SO. FT. Owner Address: PO Box 773471 Total Bedrooms: 7 Permit Bedrooms: 7 Eagle River. AK 99577-0000 This permit is for the construction of: Q✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank E] Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. This permit issued for Autumn Ridge Lot 10 Received By: Issued By: Date: Date: 2 1I of Municipality of Anchorage • j, Development Services Department Building Safety Division Onsite Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 1) 1 157 - 65I' O -1 Permit Number 5WO10485- Mailing address (2) Zip Code 99577 Legal description (Lot, Block & Sub'd.) LOT 10: AUTUMN RIDGE SUBDIVISION Legal description (Section, Township & Range) N/A Lot Size ZZ I 'l 1 S7'9-- Acres/Sq.Ft. Number of Bedrooms 7 THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well 0 Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and Is In accordance with applicable Municipal codes. ALASKA WATER & WASTEWATER CONSULTANTS, INC. Permit Fees: Date of Payment: 0� /D b / Receipt Number. .4 ZZ oma._ Waiver Fees: (07—C). o Date of Payment: o / b �bf/ Receipt Number. ALASKA WATER & WASTEWATER CONSULTANTS, INC. December 6, 2001 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, Alaska 99519-6650 Eytsmd(r tA)F't L' t,Was {3,�j f..\k W O0-AuLiNlr Ref: Proposed Well and Septic System for Lot 10, Autumn Ridge Subdivision To whom it may concern: The proposed 7 bedroom house will be served by a private well and septic system. Two test holes weere excavated on the property and logged by Michael E. Anderson, P.E. An additional test hole was excavated by our firm next to TH-53 to confirm the soils classification. We are proposing that a 2000 gallon septic tank be installed outside the 100 foot well radii and also a deep trench type drainfreld be installed around the 30 foot radii of TH-53 and TH#1. Comments regarding the proposed design are summarized as follows: 1. SOILS: Attached are the logs which shows the soil classifications, groundwater monitoring, and the percolation test results. It is our opinion that an application rate of 1.2 gallons/day/ft2 should be used and that the SM layer at 14.5 feet should act as a sand filter. 2. TRENCH DESIGN: a. Percolation Rate: <1 minutes/inch b. Allowable Application Rate: 1.2 gallons/day/ft2 c. Number of Bedrooms: 7 d. Design Flow: 1050 gallons per day e. Minimum Absorption Area: 875 ft2 f. Total Depth: 10 feet (max.) g. Effective Depth: 6 feet h. Width: 2.5 feet i. Reduction Factor: N/A j. Minimum Length: 80 feet total length (2 @ 40 feet long each) k. Effective absorption area = 960 flZ 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 6901 Debarr Road, Suite 2B • Anchorage, AK 99504 Ph: (907) 337-6179 • Fax: (907) 338-3246' Website: akwwc.com 4. TOPOGRAPHY: As can be seen on the attached topography site plan, the average topography in the area of the proposed septic system is a 5% to 15% percent running from approximately north to south. The trenches are to be installed parallel to slope contours. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your nssistnnce_ Z.S. NOTE: Attached is a site plan drawing, a design drawing, a topography site plan, two soils log, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B' Anchorage, AK 99504 Ph: (907) 337-6179 • Fax: (907) 338-3246 • Website: akwwe.com LOT 3A: HANSHEW HEIGHTS S/D F1313-- / /5 ZI o / LOT 4D; / .jam? HANSHEW HEIGHTS QI A \\\ j �I ❑EO / '\ ❑ TH-15 00 Cel z' I 5 LOT �E. OE LOT 38:I 11- EP'T0 HANSHEW HEIGHTS S/D i v EP` 1H-se 0 Y/ ` / / PROPOSED\ / 7 BEDROOM \ IH-59 HOUSE \ I I / q _ -49 TH-eo IH-51 of-s2 AUTUMN RIDGE S/D AUTUMN RIDOT GE S/D PROPOSED SEPTIC SYSTEM (SEE DESIGN, PAGE 2 OF 2) ALTERNATE SITE Tract A LITTLE CAMPBELL CREIX �... . .' DA 2/3/2001 L� ALASKA WATER R WASTEWATER J.L M. CONSULTANTS, INC.-1 • = 100, j""""" .. .........) ARa OFAARR ROAD. SIATF ?R • ANCHORAGE. AK co5GA • rHORF (o 7)33) A110 • FAX (oon356.3?4e PREPARED FOR PHONE NUMBER: PAGE NUMBER:... ...... ........ Li MASTERPIECE HOMES C/o KELLY HEITSTUMAN 884-1234 1 OF 2 (� Je fr ess: <lL LEGAL DESCRIPTION: 4yIV '•.. —79$3 `<'> AUTUMN RIDGE SUBDIVISION; LOT 10 n y%�s. ' •.,, TYPE OF WORK: yTv�dProfese{DO�.,.x�' SITE PLAN FOR PROPOSED WELL LOCATION AND SEPTIC SYSTEM y^y�Vy�j TH-60 O Ile NOTE: THE CONTRACTOR SHALL HAVE THE EST PROPERTY LINE AND ALL 100 FOOT WELL RADII FOR WELLS THAT HAVE BEEN INSTALLED, FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION A� i� � I 1 PROPOSED \ 7 BEDROOM 1 HOUSE \ F PROPOSTANK ED GALLON CO �INSTALL DOUBLE //// CLEANOUTS xunu3 •AWWC._ IN TOTAL LENGTH). ADD 6 FEET OF CLEAN, WASHED SEWER DRAINROCI INSTALL TRENCHES PARALLEL TO ALL SLOPE CONTOURS. ALTERNATE SITE. WILL REQUIRE THE OF AN INNOVATIVE TYPE EPIC SYSTEM. r---------_� OTH-52 r---:-- ALASKA WATER & WASTEWATER CONSULTANTS, INC. 6001 DFRARR ROAD. SUITE tR • ANCHORAGE. AN 0030E • Pe F (0071331-0170 • FAX (007)33gJTL6 REPARED FOR PHONE NUMBER MASTERPIECEHOMES C/o KELLYHEITSTUMAN 884-1234 AUTUMN RIDGE SUBDIVISION; LOT 10 12/3/2001 < )WN BY: J.L.M. ap F _ 40. °... :E NUMBER Q 2OF2 DESIGN OF PROPOSED WELL LOCATION AND SEPTIC SYSTEM CA..GWess•� 7953 h ..... • •eSicd Z.e ^ 1 11_ 40� rw 9 2/ �N / 348 346 344 342 35 I ALASKA. WA o NVASTEWATElR 'S. INC. IJUIL LUV - rLr%LULAIIVl-4 IGJII LEGAL DESCRIPTION: AUTUMN RIDCE SUBDIVISION; LOT 10 PERFORMED FOR: MASTERPIECE HOMES DATE; 12/6/2001 (feORGANICS EST HOLE #1 1 ==== DEPTH TO GROUNDWATERI DATE . _ �v" PROPOSED 7 BEDROOM HOUSE rSOIL V i : '-i CLAS CATIONS ORG Izz::=:: r r 111111111ML �pN 6� Gp Np e I�111�1GM CIL N/NNS • r S EP r SYSYTEM 0 0 AWWTM'M0. 0 S1 �TM s: IIIIIIIIIMH c. SITE PLAN SITE 1' 100 _ CH r r 311`�IISM4.66. • sc DEPTH TO GROUNDWATERI DATE DATE READING . _ �v" PROPOSED 7 BEDROOM HOUSE �.•. V i : '-i / 1 Gp4�pN P�Ep �pN 6� Gp Np e PROPOSED S EP M-56 SYSYTEM 0 0 AWWTM'M0. 0 S1 �TM s: ALTERNX c. SITE PLAN SITE 1' 100 DATE READING CLOCK NET TIME TIME (MINUTES) WATER LEVEL NET DROP READING (INCHES) NO Gp4�pN P�Ep �pN 6� Gp Np e 19 J I PERCOLATION RATE _ (MIN./INCH) _PERC. HOLE DIA. 6' (INCHES) III JII TEST RUN BETWEEN FT. AND FT. 20 COMMENTS: Sows EvA�Hn-�onl tC�&nl CH ��1- �C�aP �Si f -f -- PERFORMED BY ALASKA WATER do WASTEWATER I, JEFFREY A. GARNESS. CERTIFY THAT THIS W ERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: L Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Performed For: Bob Klein Date Performed: 12/8199 Legal Description: Lot 10. Autumn Ridge Subdivision SLOPE SITE PLAN 11 1 PT/OL 1 11 12 13 14 15 17 18 19 Was Groundwater Encountered? No If Yet, What Depth? Depth to Water After Monitoring None Date: 1/22100 Cobbles To 8" Bottom of Hole Perc. Rate: LT 1 Min./Inch Perc. Hole Diameter: 6" Test Run Between 4 Ft. and 5 Ft. Comments: Percolation Cavity Presoaked Prior to Testing. Performed By: A. Harala. I, Michael F. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 1/20/00 Reading Date Gross Time Net Time Depth To Water Net Drop 1 9 -Dec 1:18 4- 2 1:19 1 10.13" 6.13" 3 1:21 4.13" 4 1:23 2 10.13" 6" 5 1:24 4" 6 1:26 2 9.94" 5.94" Mu0icipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Ferformed For: Rob C - Legal Description: I ot 10 Autumn Ridge St ffidivision •- 1 5 8 9 10 11 12 13 14 15 16 17 18 19 PT/OL TESTHOLE NO 52 GP Ground Water Was Groundwater Encountered? Yes If Yes, What Depth? 7.5' Bottom of Depth to Water 9 -Dec 1:18 Hole After Monitoring 7.5' Date: 1/22/00 Date Performed: SITE PLAN 12/8199 Reading Date Gross Time Net Time Depth To Net Water Drop 1 9 -Dec 1:18 4' 2 1:19 1 10.13" 6.13" 3 1:21 4.13- 4 1:23 2 10.13" 6" 5 1:24 4" 6 1:26 2 9.94" 5.94' Perc. Rate: LT 1 Min./Inch Perc. Hole Diameter: 6" Test Run Between 4 Ft. and 5 Ft. Comments: Percolation Cavity Presoaked Prior to Testing. Performed By: AA Hula 1, Michael F. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 1/20100 Ci g656y8 • Municipality of Anchorage Q •�� 1_ On-Site Water&Wastewater Program U % < 1. (907)343-7904 Nl�f86. E3 CERTIFICATE OF ON-SITE SYSTEMS APPROVA ' 9 5 Parcel I.D. 015-051-04 615- 651-(--(3 Expiration Date: / `` 1. GENERAL INFORMATION Complete legal description AUTUMN RIDGE:LOT 10 Location(site address) 9435 NICKELL CIRCLE'ANCHORAGE,AK Current Property owner(s) RICHARD MUHLENBRUCH Day phone 907-227-6911 Mailing address Real Estate Agent Day phone 2. TYPE OF DWELLING: Single Family(w/wo ADU) ❑ Duplex ❑ Multiple Dwellings(Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 7 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual.Well Individual On-site U Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System 0 Public Sewer ❑ WaiverNariance request for. N/A Distance: - Received by: (4 Date: /07,/ COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee$ 5210 Waiver Fee$ Date of Payment 1O/f(,/I, ' Date of Payment Receipt Number c, Oat-1416 Receipt Number COSA# O5C1 215 Waiver# �I� 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 *ANCHORAGE,AK, 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date /0 hi/ e Engineer's Comments: • In conducting this evaluation,GEG provided an engineering evaluation of the well and/or septic system in accordance with the .......111111%* 1 guidelines and regulations established by the Municipality of Anchorage and industry practices.The reported results describe the .4`. condition of the systems on the date/s of the evaluation.Separation distances were measured to readily identifiable features. �� \ �� Hidden defects or encroachments mayexist that were not identified duringthe evaluation.The �� •'•••••, operational life of all wells and septic : • �• ;•' •. systems depend on a variety of variables including,but not limited to,soil conditions,groundwater levels(that may fluctuate during ••'• • the year),quality of construction(materials and workmanship),and the water usage of the famity utilizing the system's.These PFI 4 F. \ * �, conditions can vary,and are outside the control of GEG.Satisfactory test results do not guarantee future performance of the % system's;therefore,GEG makes no warranty(express or implied)regarding the future performance of the well or septic system. • GEG makes no representation whether an alternative well or septic system can be installed on the property in the event either of the , .,: 1 current systems fail.The content of this report is for the sole benefit of the person/party who retained GEG.Reliance upon the 0 ten; e rey A. Garness Lv a information provided in this report by any other person or party,including but not limited to subsequent property purchasers,is not •��� o C E 7 53 i authorized.In short,GEG disavows any legal duty to anyone other than the person/party who paid for this report. • 6. DSD SIGNATURE v• PROFESS\ P44 LICENSE ,�*1 %%%%" /xJ #AECC884 System#1 Approved for bedrooms. System#2 Approved for bedrooms. k t •vr,��� Disapproved. \G� G ON-SITE ?-., Conditional approval for bedrooms, with the following stipuleionwATER AND WASTEWATER o vs PROGRAM By: / Original Certificate Date: if --/ (—y icc) The Municipality or Anchorage Develop,emt Services Division(DSD)issues Certificates of On-Site Systems Approval(COSA)based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Nitrate Advisory • Septic System Advisory Arsenic Advisory Well Flow Advisory Other (Rev.10/12/12) If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: AUTUMN RIDGE: LOT 10 Parcel ID: 015-051-04 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) YES Date completed 5/31/2002 Sanitary seal (Y/N) YES Wires properly protected (Y/N) t/ Total depth 210 ft. Cased to 210 ft. Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 5/31/2002 9/18/2018 Static water level 185 ft. 187 ft. Well production 8-10 g.p.m. 5.6+ g.p.m. WATER SAMPLE RESULTS: Coliform O colonies/100 ml. Nitrate"- • mg./L. Collected by: GEG, Ltd. Arsenic: N° ug./L. Date of sample: 9/19/2018 B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 12/13-14/2001 Tank size 2000 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout(Y/N) YES Depression over tank (Y/N) NO High water alarm(Y/N) N/A Date of pumping I ) 'i �) Pumper i�/1r.f . , 47 ./(2<z'key);YJc‘1) C. ABSORPTION FIELD DATA 'BELOW EXISITNG GRADE AT MT3 OF NORTH TRENCH NORTH/SOUTH Date installed 12/13-14/2001 Soil rating 6..p.d sor ftz/bdrm) 1.2 System type DEEP TRENCH Length 42/40 ft. Width 2.5/2.5 ft. Gravel below pipe 6.0/6.0 ft. Total depth *13.9+ ft. Eff. absorption area 984 ft` Monitoring tube YES Depression over field NO Date of adequacy test 9/18/2018 Results (Pass/Fail) PASS For 7 bedrooms Fluid depth in absorption field before test 24 in. Water added 1947 gal. New depth 40 in. Elapsed Time: 1425 min. Final fluid depth **31 in. Absorption rate >= 1050+ g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N &type) NONE KNOWN If yes, give date - • TESTED SOUTH TRENCH ONLY, CONDITION OF NORTH TRENCH IS UNKNOWN • MT1 EXTENDS APPROXIMATELY 6.08'BELOW CLEANOUT#1 • MT3 EXTENDS APPROXIMATELY 5.75'BELOW CLEANOUT#3 • CLEANOUT 2 AND MT2 ON WEST END OF NORTH TRENCH ARE NON-FUNCTIONAL FOR ITS PURPOSE • **THE LIQUID LEVEL(LL) IN THE DRAINFIELD ROSE TO APPROXIMATELY 32"WITH THE INTRODUCTION OF THE FIRST 167 GALLONS; IN SHORT,THE DRAINFIELD ABSORBED THE REMAINING 1780 GALLONS OVER THE REMAINING DURATION OF THE TEST(APPROXIMATELY 196 MINUTES)AND THE RECOVERY PERIOD • PER MOA RECORDS,THE SUBJECT LOT WAS NOT ELIGIBLE FOR A COSA DUE TO INADEQUATE SOIL COVER OVER THE TANK. PER GEG INSPECTION ON 9/18/2018 THERE IS APPROXIMATELY 4.75'OF SOIL COVER OVER THE SEPTIC TANK D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at '• a er alarm level at in. - . •• Cycles tested Meets alarm &circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main 75'+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank 100'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS � G. ENGINEER'S CERTIFICATION .4.<P, ,.• .. f/T; %\ * •j I certify that I have determined through field inspections and i . •,'• • review of Municipal records that the above systems are in e • • conformance with MOA COSA guidelines in effect on this •• sr•• •I• • ; date. ♦ . J ff` A. Gain - Engineer's Printed Na e JEFFREY A. GARNESS 4� S�t� CE— 9 3el. �, Date /2:,/i *• PROFESS\, ,4 LICENSE ��11,As"i��� #AECC884 (Rev. 10/12/12) Lu _ 8474 L=7.48 — U R=50.00 N89°56'04"E 199.64 S _J UJ c/ 57 �`\\, i I-5 E I Ret.waM(typ si• 6; � P'T'T.-.._:fi.•. ..Y. •.• •0 Z L__ 4 1 v ��\ O r:.` N89°56'04"E 79.79 '..W!::r:''' . - 1 ''''-�r�:: \ / _. ..i 1u``.` . of 13.9 _ '.:•.s.1/4:-'•` st x-9.0 `?v <: ::+ N / 12.6 Ni 10.2 m ti . -f.; :.: 23. 6.0� 3Story Frame House �<':-= 'fi:- . '4.2 : ' ti „ , •6.4"./ f 5.7 - "'ice';,:. ^._.:.2 1Lo 3.6 •• 21.2y �r:c tT CO Z.0• cV SCO (\i unri:mnn v W Lot 9 Lot 1 LOT 10 `-" N • .. c. O s 0 W fSeP��e"tlrlPl a 0 a) (!� N O O 0 O O 38.16 _— — � N `� N81°46'02"E '• Open Space SCALE: 1"= 50' 64.08 t�N (Class B Wetlands) 109023'52"E ```N.X``+ AS-BUILT NO CORNERS SET THIS DATE OF A4 1 I I hereby certify that I have performed a Mortgagee's inspection ARV QK�• ' • ' C;qS ,� of the following described property: LOT 10, AMWAily /.49th �\ •,�7 I. AUTUMN RIDGE SUBDIVISION • ••••* Anchorage Recording Precinct,Alaska,and that the p4 . ..... •. .' improvements situated thereon are within the property lines ' j and do not overlap or encroach on the property lying '4 ..'elizobeth L. Wolotka :if/ adjacent thereto,that no improvements on the property lying ��', 8036 — LS ••• •Q� WI adjacent thereto encroach on the premises in question and foe••'° • • • . • •• c, that there are no roadways,transmission lines or other •baa visible easements on said property except as indicated I � w• oFfssloL hereon. 1 4 1,X‘‘%%. Dated at Anchorage,Alaska EASEMENTS OF RECORD, OTHER THANq this 28th day of JUNE ,2018. THOSE SHOWN ON THE RECORDED �' I ' 6 FRED WALATKA&ASSOCIATES, L.L.C. PLAT ARE NOT SHOWN HEREON. Engineers and Surveyors UNLESS OTHERWISE NOTED FB 18-7, pg 1 BE 907-248-1666