Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T12N R2W SEC 30 W2SE4NE4NE4SE4
TI 2N R3W Sec. 30 W2 SE4 NE4 NE4 SE4 #021-022-50 Municipality of Anchorage o Development Services Department .~ Building Safety Division ~-~ On-Site Water & Wastewater Program. 4700 South Bragaw St. ~ P.O. Box 196650 Anchorage, AK 99519-6650 ~ www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW040392 PID Number: 021--022--50 Name: GEORGE & GLENDA STEVENS WastewaterSystem: [] New · Upgrade Address: 13315 GLEN ALPS ROAD * ANCHORAGE, AK 99516 ABSORPTION FIELD Phone: NO. of Bedrooms: (907) 348-7333 ¢ [] Deep Trench · Shallow Trench [] Bed DMound DOther LEGAL DESCRIPTION .o..a.n0= '.~o, De.b, ..... ,,,.a, 6.0 g,D/s,. Ft. SEE DWC. Block: Lot: Subdivision: Depth th pipe bo[tom from original grade: gravel depth beneath pipe: W2, SE4, NE4, NE4, SE4, SEE DWG. F~. 0.5+ F~. Township: T12N Range: R2W Section: 30 Fill added obey° original g~de: ~rovel length: SEE DWG. ~t. 40 F~. WELL: [] New [] Upgrade 5 ,t. 1[ - p~. .~ Ft. 200+ SO, Ft. D 3054/ F--810/ SCH 40 PVC ~ .~. DENALI SEWER 10/7-8/2004 SEPARATION DISTANCES ~Se,tio ~Nold~.~ ~S.T.~.P. .Other* T..rom~--..~° Septic Absorption Lift Holding =ublic/Privote Monufaciurei': Cap0~ity in galJe~l$: Tank Field Station Tank So,,, U.~, ANCHORAGE TANK 1500 Well 100% 100'+ 100'+ - 25% Mature*: STEEL Numl~r of comportmen~$: 2 Su~ooe Water ~00'+ ~00'+ ~00'+ - - LIFT STATION Lot Line 5'+ **5'+ 5% -- - 1500/86IANCHORAGE TANK/ORENCO SYSTEMS "Pump on' lever or: rPump off' leYel ~3~: )High ~ter alarm at: Foundation 5'+ 10% 5'+ - -- TIMER/29"r TIMER/23.5"i 46"/56.75" Curtain Drain NONE KNOWN I I #2O OSl O5 HHF ~ ~ JOHNS SERVICES F~emork$: BENCH MARK · THIS l$ AN ADVANTEX TREATMENT SYSTEM GARAGE SLAB · *WAIVER GRANTED IA...,~d 100.00 F~. ....... Inspections performed by: GLO, Ltd. Dates: 1st 10/7/2004 ~ 2nd 10/7/2004 ~ , 3rd 10/8/2004 ~ess,- ..' Development ,~ervices Department Approval -~[~,~,~,...(/... _~ ./~,~ .?~ Reviewed and approved by ,~ PER,,T NUMBER: UILT DRAWING SW040592AS-BPARCEl 10 NUMBER: 021-022-50 ~ o 100' WELL RADIUS ~ UH1 39.11 28.25 45.77 / MH2 40.67 51.91 49.39 ~ I MTa ,04.06 ~7.~1 ~00.77 j ~,r ~ NEW DRAI~FIELD II I I ~ II ~o~o NE~ 1500 GALLON ADV~EX X~ ~ ~00' WELL RADIU~ q / DATE: PREPARED FOR: PHONE NUMBER: PAGE NUMBER: GEORGE & GLENDA STEVENS (907) 548-7355 2 OF 5 LEGAL DESCRIPIION: AS-BUILT DRAWING OF SEPTIC SYSTEM UPGRADE PER ,TNUM.ER: AS BUILT DRAWING PA.OE',. $W040592 -- 021-022-50 TOP OF MANHOLE TOP OF TANK TOP OF TANK *TEST HOLE WAS PR~IOUSLY FLOODED WITH SURFACE RUNOFF DUE TO fi" SNOWMELT AND RAINFALL, WATER ~ L~EL DROPPED 8.5" FROM 10/5/04 TO 10/6/04. I /~ ~ FINAL G~DE ~ = 107.46+ ~ INSU~TION INSTALLED B~CING ~ ~LTER F~RIC ~;4~?~,~¥~,~T**.~'.~:~ *EL~ATION OF GROUNDWATER = 104.72 (AVG.)~ RESTIVE EL~ATION OF GARNESS ENGINEERING GROUP, Ltd. GEORGE ~ GLENDA STEVENS (907) 548-7535 , Of, ~: :~i~;s..' ~ ............... T12N, R2W, SECTION 30; W2, SE4, NE4, NE4, SE4, PROFILE AS-BUILT DRAWING OF SEPTIC SYSTEM UPGRADE Oct 1204 Ol:lBp To whom it may concern I, John Hauth completed the installation o£the septic tank control system for George Stevens. The .... wiring is ~nstalled to meet the standards of the NEC. My State electricians license # is 00115007. ! can be reached at 348-0406. Thanks MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Sep 20, 2004 Expiration Date: Sep 20, 2005 Permit Number: SW040392 Legal Description: ~I~4~~4~IE4~E4~ Design Engineer: 0855 Garness Engineering Group, LTD Owner Name: GEORGE & GLENDA STEVENS Owner Address: 13315 GLEN ALPS ROAD ANCHORAGE, AK 99516- Parcel ID: 021-022-50 Site Address: 013315 GLEN ALPS RD Lot Size: 54450 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~ ~,'~-~ Issued By:~- Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O, Box 196650 A~.chorage, AK 99519-6650 www. ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERHIT APPLICATION FOR A SINGLE FAHILY DWELLING Permit Number Property owner(s) GEORGE AND GLENDA STEVENS Day phone 348-7353 g address (1) P.O. BOX 110232 * ANCHORAGE. AK. g address (2) /~"~'5~'~ ~ ~ q~¢~' ZipCode 99516 Legal description (Lot, Block& Sub'd.) T12N. R2W. SEC. 30: W2. SE4. NE4. NE4. SE4, Legal description (Section, Township & Range) Lot Size --~/'/, q~) Acres/Sq. Ft. N/A Number of Bedrooms THIS APPLICATION IS FOR: Sewer Only [] Well Only [] Sewer and Well [] Water Storage [] Sewer Upgrade · THIS PROPERTY CONTAINS: Hot Tub [] Jacuzzi [] Swimming Pool [] Water Softening Unit [] Therapy Pool [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit Fees: ~0 Date of Payment: Receipt Number: 05 Waiver Fees: //'~ Date of Payment: Receipt Number: Municipality of Anchorage P.O. Box 196650 · Anchorage, Al,'~ska 99519,6659 ·Tclcphone (907) 843-8501 · Fox (907) 843-8200 4700 Bragaw Street · Anchorage, Alaska 99507 Mayor Mark Begich Building Safety Division 9/20/2004 Jeff Gamess Garness Engineernig Group 3701 E Tudor Rd Anchorage, Alaska 99507 Subject: Waiver Request for T12N R2W SECTION 30 W2,SE4,NE4,NFA,SE4 Waiver Request #WR040073 Parcel ID #021-022-50 Dear Jeff Garness: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to property line has been approved. The approved separation distance is 5.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, 'qgivil Engineer On-Site Water & Wastewater Program Community, Security, Prosperity GARNESS ENGINEERING GROUE Ltd. CONSULTANTS & GENERAL CONTRACTORS - October 6, 2004 Municipality of Anchorage Development Service Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, Ak 99519-6650 (907) 343-7904 Revised Design: Permit# SW040392 Ref: Proposed Septic System for T12N, R2W, Section 30; W2, SE4, NE4, NE4, SE4 To whom it may concern: A permit (SW040392) was previously issued on 9/20/2004. Per the homeowners request we are revising the design for 4 bedrooms. Due to a rise in groundwater an Advantex treatment system will be used. The drainfield will be designed mound the 30 foot radius of test hole #2. We are proposing to install a 1500 gallon Advantex tank with a pump vault and a 5-wide type drainfield. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. TRENCH DESIGN: a. Percolation Rate: <1 - 1.3 minutes/inch b. Proposed Application Rate: 3.0 gallons/day/fi2 c. Number of Bedrooms: 4 d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 200 ft2 f. Total Depth: 2.0 feet (remove organics) g. Effective Depth: 0.5 feet h. M.O.A. Approved Sand Filter: 2+ feet i. Width: 5 feet j. Minimum Length: 40 feet long k. Effective absorption area = 200 ft2 Note: The distribution lines are to be 1.25 inch SCH. PVC with ¼ inch dianaeter holes spaced 15 inches on center (30 holes total.) 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: garnessengineering.com 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic system. 4. TOPOGRAPItY: As can be seen on the attached topography site plan the average slope down hill from the drainfield is approximately 5 to 10 percent running southeast to northwest. The drainfields are to be installed on the toe of a 25 percent slope. The In short, there are no slope concerns. 5. WAIVER: We request a 5 foot lot line waiver from the east lot line to proposed drainfield. We are unaware of any adverse impact this would have on the adjacent lots. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. P.E., M.S. NOTE: A site plan drawing, a design drawing, two soil logs, and a 7page construction specification letter which are all part of the design package for this septic system. 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: gamessengineering.com I T12N, R2W, SEC 30, W2, tl NE4, NE4, NEA, SE4, SITE S/D; LOT 1, ] ] S/D; LOT 2, ~ ] .~ Xx j X --PROPOSED SE~IC UPGraDE / G'[E~ ALPS EST. T12N, R2W, SEC 30, GARNESS ENGINEERING GROUP, Ltd. ~: PRePAReD FOR PHONE NUMBER: PAGE NUMBER: ~.,. GEORGE & OLENDA STEVENS 348-7333 1 T12N, SITE P~N FOR SEPTIC SYSTEM UPGRADE (ADVANTEX) /NOTE': THE CONTRACTOR 'SHALL HAVE THE EAST LOT LINE AND WELL RADII SHOWN FLAGGED BY A REGISTERED LAND SURVEYOR PRIOR TO CONSTRUCTION. ~ / t PROPOSED DRAINFIELD. EXCAVATE A TRENCH THAT IS ~' i TO BE 2 FEET DEEP MAXIMUM (EXCAVATION TO BE / I LIMITED TO THE REMOVAL OF ORGANICS) BY 5 FEET ~ I WIDE BY 40 FEET LONG. ADD2 FEET OF M.O.A. / APPROVED SAND FILTER AND THEN 0.5 FEET OF CLEAN, WASHED SEWER DRAINROCK. THE DISTRIBUTION ~ I LINE IS TO BE 1.25 INCH PVC w/ 1/4 INCH HOLES ; ~ SPACED 15 INCHES ON CENTER (30 HOLES TOTAL) ~ I ALTERNATE SITE WILL / REOLURE THE ~, : REMOVAL OF SHED COMPLETELY ABANDONED-~. }~' "~%~ I ~ "-J~.:':. ,L :~ .,- .. LJ ~1 ~PROPOSED ORENCO ~/ REQUESTED / x / C.J.G. CONSULTAN?S & GENERAL CONTRACTOE$ ~ ~ 3REPAREO FOR: PHONE NUMBER: PAGE NUMBER: GEORGE AND GLENDA STEVENS $48-7353 2 OF 4 ~P~ OF woR~: ~o~o~ DESIGN FOR PROPOSED SEPTIC SYSTEM UPGRADE ,,y,~-s*em~ NOTE= THE BOARO ,NSU~T,ON TO AdvanTexTreatment B~OND ON ~L SIDES EXCE~ UNDER AX Series - MOde Ia ~ THE ADVANTEX RLTER. THIS WILL ~LOW o~enc~sy~ms~ FOR H~T TO ESCAPE FROM TANK One (1) 40x96 Pod '~' .,~ ~o FROM TANK TO FILER INLET~ - -' ' ~ ADVANT~X TANK ~OEENCO ~, ~ ..... ~ EFFLUENT ~ PUMP CON~LTANT8 & GENIAL CONT~CTORS N.T.S. PREPPED FOR: PHONE NUMBER: ~AGE NUMBER: ';"' GEORGE & GLENDA STEVENS (907) 348-7335 ~pET12N'oF WORK:RZW' SECTION 30; W2, SE4, NE4, NE4, SE4, qh*~l".. ADVANTEX PROFILE ~ THE DISTRIBUTION LINE IS TO BE 1.25 INCH PVC w/ 1/4 INCH HOLES SPACEB 15 INCHES ON CENTER (30 HOLES TOTAL) FINAL GRADE MT INSULATION ~ RLTER FABRIC INSTALL BP, ACING AND STAKING INSTALL BRACING AND STAKING ORIGINAL GRADE ~THE DISTRIBUTION LINE IS TO BE 1.25 INCH PVC WITH 1/4 INCH HOLES SPACED 15 INCHES ON CENTER (30 HOLES TOTAL) GARNESS ENGINEERING GROUP, Ltd. ~LE: C.J.G. '" -- CONSULTANTS & GENERAL CONTRACTORS .,. ~.- .I GEORGE &: GLENDA STEVENS (907) 548-7355 4 OF 4 T12N, RZW, SECTION 50; W2, SE4, NE 4, NE4, SE4, ..'"' DETAIL DRAWING OF PROPOSED DRAINFIELD FF GARNESS ENGINEERING GROUP, Ltd. ISOIL LOG - PERCOLATION TESTJ LEGAL DESCR,PT, O.: T12., R2W. SEC. PErFOrMED FOR: . GEORGE & GLENDA ST~ENS DATE: g/Y/2004 "-. DEPTH ~ (feet)~ [TEST HOLE ~1l ~ ~ o~lcs AND P~T~ SOIL C~SSIFICATIONS -" I I 2 ~},~,~¢::~ OW :~ ORG I / SM/OM ~ SP CH ) TH~2 SH OH SC ~ FRACTURED GROUNDWATER DATE / ~ ~ BEDROCK DRY ' 9/7/2004 ~ ~. DRY - 9/14/2004 x ~oo' ~LL ~U8 I 5,1' 10/5/2004 x~ I SITE P~N 10 ~ / 1 =100 11 DATE READING CLOCK NET TIHE WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 12 9/8/2004 19 PERCOLATION RATE 1.3 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 5.0 FT. AND 5.5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORHED: ~ YES ~ NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORHED BY: CALEB GALL CONHENTS: PERFORMED BY 6EG, Ltd. I, JEFFR~ A. GARNESS, CERTI~ THAT THIS WAS P~RF~RMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ~O/G/O DEPTH TO GROUNDWATER DATE DRY _9/7/2004 DRY 9/14/200~ $.1' 10~/5/2004 IG,GROUP, Ltd., ~-~ ~A,R~N~ESS E GINEERI~,o~-,-,,-----.--.--~/ ~,.~.&?'~.'!~ ~]'?~?0~0!l. . JSO'/ LOG - PERCOLATION TESTI ' ~J / LEGAL DESCRIPTION: T12N, R2W, SEC. 30; W2 SE4 NE4 NF4 SE4 ~'":'~ PERFORMED FOR: GEORGE &: GLENDA STEVENS DATE: 9/7/2004 I~EPTH ~ TEST HOLE #2 SOIL CLASSIFICATIONS '~ i · ~.=~ ,,~-~.?~, GP HL / GN CL * GC OL ,~- // sw ~ SP CH ~ ) TH#2 DEPTH TO , GROUNDWATER DATE .~ ,~ \\\ 8 ~ FRACTURED DRY 9/7/2004 " BEDROCK DRY 9/14/2004 ~x ~oo' W~L 9 4.2' 10/5/2004 ~\ I SITE PLAN \ / 10 \ 11 DATE READIN( CLOCK NET TildE WATER LEVEL NET DROP Tilde (ldINUTES) READING (INCHES) 12 9/8/2004 - ~..~.~ 15 g ro/~' ..... 17 19 PERCOLATION RATE <1 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 2.5 FT. AND 5.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: [] YES · NO SOILS LOGGED BY: SUSAN OSWALT PERCOLATION TEST PERFORMED BY: CALEB GALL COMMENTS: PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS ~PE~FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DEPTH TO GROUNDWATER DATE DRY 9/7/2004 DRY 9/14/2004 4.2' 10/5/2004 �- Altuli cip alAy of Anchorage orage � Q Department of Health and Human Services 825 "L" Street Rick Mystrom, P.O. Box 196650 Anchorage, Alaska 99519-6650 Mayor 907-343-4744 December 18, 1997 George Stevens 13315 Glen Alps Anchorage, AK RE: On -Site permit #SW960174 Dear Mr. Stevens: This office mailed to you a letter dated November 7, 1997 which referenced several concerns that remain regarding your well and wastewater disposal system located at T12N, R2W, Section 30 Wr/z SEr/4 NE'/4 NE'/4 SE'/4. That letter requested that you respond to these concerns by December 1, 1997. No response has yet been received by this office. As a result we are issuing to you a Notice of Violation listing the sections of the Anchorage Municipal Code (AMC) with which your wastewater disposal system is not in compliance. We would like to work with you and your engineer on a plan of action for the wastewater disposal system currently in place. Please respond to this request by Friday, January 9, 1998. We will require a wastewater disposal system that complies with AMC Chapter 15.65 Wastewater Disposal Regulations. This department's approval must be complete by June 15, 1998 or we may issue a citation. Citations may carry a fine of up to $300 per day, for each day the wastewater disposal system is not in compliance. We appreciate your cooperation in resolving this situation. If you have any questions or comments, please call us at 343-4744. S' rely, W n4 J es Cross, P.E. Program Manager On -Site Water Quality enclosures: Notice of Violation #8502 Copy of letter dated Nov. 7, 1997 �oQ`� Municipality of Anchorage gy.►� Department of Health and Human Services 825 "U' Street - ok elystrem. P.O. Box 196650 Anchorage, Alaska 99519-6650 Mavor •907-343.4744 CP,9,:S To: George Stevens 13315 Glen Alps Anchorage, AK Property: T12N, R2W, Sec. 30 W %:, SE'/4, NE 114, NE 1/4, SE'/e Permit #: SW960174 Re: Response to Oct. 22 Owner Report Date: November 7, 1997 Dear Mr. Stevens; We appreciate your prompt response to issues regarding your septic system and well. Some of our concerns have been addressed, however there are some areas which still need to be clarified. 1) The 2 foot separation distance between the bottom of the field and bedrock. The existing condition of a sand filter surrounded by an impermeable membrane which extends to bedrock is not an acceptable situation and has not been suitably addressed. It appears that this has thus far been addressed with the highlighted comment from the Typical Nide Drainfield Requirements and Specifications sheet from our department and the statement from your October 9 report that there is native soil under the sand filter. The comment highlighted from the `Sample Wide Drainfield Calculations' may have been taken out of context. The statement reinforces that the given example meets the 2 feet of native soil requirement. (3'/2 feet cover + 6" from bottom of pipe to bottom of cover + 3 feet sewer rock = 7 feet total depth. That leaves 2 feet of native soil below the bottom of the trench remaining from the 9 foot depth of the accepting stratum.) The Anchorage Municipal Code (AMC) classifies fractured bedrock the same as bedrock. Therefore the "native soil consisting of sandy silt and shattered rock" is still classified as bedrock and either the separation distance must be met, or justification for waiving this separation distance must be furnished. The AMC 15.65.060-H provides that "Tire Department may approve an on-site wastewater disposal system that does not conform to this Chapter if the Department finds, after consideration of relevant test results, engineering data, publications and other materials, that the system will Anction as effectively as a system that conforms to this Chapter. The applicant shall be responsible for ftrnishing proof that the system will function as effectively as a system provided for in this Chapter. " Please supply us with a proposal for modification of the disposal field which addresses our main concerns of oxygen flow to the effluent in the sand filter, effluent treatment and lateral movement of the effluent before reaching bedrock in addition to data or publications which would justify a variation from specific code requirements. 2) The separation distance from the septic tank to the well must beat least 100 feet. While drilling a new well is an acceptable solution to meeting the separation distance to the septic tank, relocating the tank outside the 100' well radius may be more cost effective for you. Either solution is satisfactory to this Department. The other necessary changes to the disposal system which you have already agreed to, include: 1) Install new central lateral on the bed at a separation distance of S feet on center. 2) Install sweep cleanouts at the far ends of all distribution laterals. 3) Grade mound so that side slopes are no steeper than 33% and plant vegetation on mound. A new As -Built report must be submitted with the completion of the changes to the system. The requirements for this report are included on the second page of the memo given to you at our October 8'h meeting. Please submit to us a strategy and justification for correcting the above requirements by Monday, December V. We appreciate your cooperation in resolving this situation. If you have any questions or comments, please call us at 343-4744. Mme ery, i r OH J es Cross, PE Program Manager On -Site Water Quality Notice of Violation #8502 Detail of Violations of Anchorage Municipal Code Chapter 15.65 Wastewater Disposal Regulations 15.65.020.A "No person may cause or permit any wastewater to be discharged or disposed of except into an on-site wastewater disposal system conforming to the standards of this Chapter... 15.65.202.13 "A lot or parcel serving a single-family dwelling and served by a well or public water supply must have an on-site wastewater disposal system conforming to this Chapter or a public sewer." 15.65.050.A.4 "A septic tank must be located no less than the separation distances required by 18.AAC.72 from water supply wells." That distance is 100 horizontal feet. This is also addressed in AMC Chapter 15.55 Water Well Regulations in 15.55.060.13 which lists the minimum separation distance between a well and a septic tank as 100 feet. 15.65.060.E.12 "A subsurface disposal field must have cleanouts.... The cleanouts must be at least four inches in diameter for gravity systems and located near each end of the field" 15.65.060.H.1 "... The soil layer used for the absorption area must be a minimum of 24 inches thick below the bottom of the gravel." 15.65.060.I.2 "sufficient filtering material as described in subsection D. of this section must be placed on top of the accepting stratum of native soil... (the accepting stratum must be a minimum of 24 inches thick)" 15.65.060.I.4 "the side slope of the top layer of the mound system exclusive of top soil must be no steeper than 33°/d" i Rick Mystrom, Mayor Mmieipaht y of Anehorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 T12N R2W Section 30 SW960174 William L Ulich George Stevens 9/25/97 afternoon 10/2/97 9:20-9:40 am 907-343-4744 W2 SE4 NE4 NE4 SE4 PE# CE -4766 work phone 786-6711 D. Mears & A. Kim D. Mears & J. Cross The As -Built submitted to DHHS has the following discrepancies, deficiencies and violations: 1. Design a) Installed system differs significantly from approved design. 15.65.150-F-6 i) Installed system is abed, approved system was a double trench. ii) Installed sand filter is 8 feet deep, approved filter was 4 feet deep. iii) Installed effective depth is 1.5 feet, approved effective depth was 6 inches. b) The absorption area calculations were based on the native soil percolation rate of 5.3 and 2 minutes/inch. The percolation rate of the sand used is unknown. 15.65.060-1-3 c) The distance between the distribution lines is listed as 10 feet and the maximum allowed for a bed is 6 feet. 15.65.060-11-5 2. Installation a) The system is owner installed. Permission was not given by DHHS for this. He was neither information submitted attesting to his qualifications, nor is he an approved excavator. 15.65.035-A. From site visit, owner states he was a project manager for many years and he has photos and receipts of the installation. b) Native soil was excavated to bedrock, the soil layer under the absorption area must be 2 feet thick. 15.65.060-H-1. The accepting stratum must be native soil. 15.65.060-1-2 c) The sand used in the filter layer is not stated as coming from an approved source, nor is a sieve analysis given as per permit special provisions. d) The side slope of the mound is steeper than 33% 15.65.060-1-4 e) The 4 standpipes in the bed are all monitoring tubes. The 2 pipes at the far end of the field from the tank need to be cleanouts. 15.65.060-E-11 3. well a) The well on the site is only 93.4 feet from the first cleanout of the septic tank. b) Nowell log was submitted with the As -Built. 4. As -Built a) Separation distances are not completely filled in b) Well information is missing c) Soil rating information is missing d) Total absorption area is missing e) Bench mark location is missing, however there is no evidence that a survey was even completed. f) Total depth of system from original grade is listed as 10 feet, however 2 soils logs recorded bedrock at 4 and 6 feet from grade. g) Depth to pipe bottom from original grade is listed as 7 feet. This does not agree with the submitted drawing & stated excavation depth. With an excavation of 10 feet and a depth to pipe bottom from original grade of 7 feet, there would only be a 3 foot separation between the bottom of the pipe and the bottom of the system. 5. Site plan 15.65.150-F-2 a) Not surveyed b) No property lines c) Neighboring wells & systems not shown d) North arrow missing e) Not to scale 6. Cross Section 15.65.150-F-2 a) Not surveyed b) Not to scale RLE �tP�R� LOCATION OF WELL LOCATION/SKETCH: STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING & WATER MGMT WATER WELL RECORD 0~: DEPTHS MEASURED FROM~casing top r"lground surface SOREHOLE DATA: Depth Material Type and Color From To Depth of hole: / ~ ft Depth of casing:,~'_..~" ft ~lV'/ /~' I~;~ -- STATIC WATER LEVEL: ft below ~Ctop of casing [] ground surface METHOD OF DRILLING: Pair rotary [] cable tool I-] other USE OF WELL:/~ domestic [] .irrigation [] monitor [] public supply [] other CASING STICK-UP' .'~ ft Diam: Casing type: ~ ' ~-T~. to WELL INTAKE OPENING TYPE: [] open end [] screened [] perforated /~open hole Depths of openings: tO ft CONTRACTOR INFORMal'ION: Regi$,;~d ~usine~-s Name , ~l~ - ~'- Scggtature of AEthorized Respre~tative Date SCREEN TYPE: Diam: in, Slot/Mesh Size: Length: ft GRAVEL PACK TYPE: Volume used: GROUT TYPE: Depth: from ft to ft DEVELOPMENT METHOD:' Duration: PUMPIN_.~LEVEL AND X!EI..D: ~A-~ ft after ~ hrs PUMP INTAKE DEPTH: __ ft Horsepower: __ WELL DISINFECTED UPON COMPLETION;r'~C:l YES REMARKS: PLEASE MAIL WHITE COPY OF LOG TO: DNRIDIVlSION OF MINING & WATER MGMT 3601 C St, Suite 800 ANCHORAGE AK 99503-5935 Phone (907}762-2538, Fax 1907)562-1384- · Municipality of Anchorage Page I of-2- DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal Syste~ and/or Well Inspection Report Permit Number: ~Wc]~O 1"7,~ PiD Numbe~0,Z. lO~.~_~"O !"'"':/_~EOR/.~ <~'TE.V~A/~' l Wastewater System: "~N'w [] Upgrade 7~c~/5 ~/_~/~J ~L/~ ABSORPTION FIELD LEGAL DESCRIPTION ~'~'"~ 7 ~EPARATION DI6TANCE~ ~,,~ · o~ ~~..~ ~ i~ ~~ ......... , tooO wa, LI~ STATION ~..~. 10 ~ %7' n~.: BENCH MARK ~IN~ Depa~ment of H~lth and Human Se~ic~ approval Review~ and appmv~ by: Da~: r Pe,"mJt No. ~ q~O / 7.,~L Page '2_ ' . of -- ~ ~uflJcipalJ~ o~ DEPARTMENT 0~ HEALTH AND HUMAN SE~VIGES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 9~1~650 · Telephone: ~3~7~ On-Site Wastewater Disposal System an~or Well Inspe~ion Repod MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 PAGE 1 OF 1 7- ~- ¢7 ~:~"~' ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW960174 DESIGN EMGIMEER:S & S ENGINEERING OWNER NAME:STEVENS GEORGE D OWNER ADDRESS:4500 DIPLOMACY DRIVE, ANCHORAGE, AK. 99508 SUITE 43 DATE ISSUED: 7/09/96 EXPIRATION DATE: 7/09/97 PARCEL ID:02102250 LEGAL DESCRIPTION: T12N R2W SEC 30 W2SE4NE4NE4SE4 LOT SIZE: 54450 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: THE ATTACHED APPROVED DESIGN. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80) . THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED OM THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: 1.) THE BOTTOM OF THE SEWER ROCK MUST BE A MINIMUM OF 6 FT. ABOVE BEDROCK (FRACTURED OR WEATHERED BEDROCK). 2.) INSTALL AN IMPERMEABLE MEMBRANE AROUND PERIMETER OF SAND LAYER TO ENSURE THE DOWNWARD MOVEMENT OF EFFLUENT. -- ~ -- 3.) THE SAND USED AS A FILTER LAYER MUST BE A CLEAN COARSE SAND FROM AN ADEC APPROVED SOURCE, OR THERE MUST BE A SIEVE ANALYSIS TAKEN SHOWING THAT THE SAND MEETS CURRENT MOA/DHHS REQUIREME~NT~. ISSUED BY: /---- ROBERT C. COWAN, RE. ROBERTA. SHAFER, RE. CIVIL ENGINEERS June 18, 1996 (907)694-2979 FAX (907) 694-1211 SEWER&WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOWTEST ROADDESIGN STRUCTURAL & MECHANICAL INSPECTIONS MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 w SE 1/4, SE 1/4, SE 1/4, Sec. 30, T12N, R2W, S.M., AK. Request you issue a permit to drill a well and install a septic system to serve the proposed three bedroom house on the referenced property. Test holes were excavated and percolation tests performed. The approximate location of the test holes are located on the attached site plan. At the time of excavation no water was encountered in test holes and after seven day ground water monitoring, the monitoring tubes were found to be dry. This property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. If you require additional information, please contact us. Sincerely, Rcc/gk Enclosure 17034 NORTH EAGLE RIVER LOOP" SUITE 204 · EAGLE RIVER, ALASKA 99577 1" ~,,l~= 60' SITE PLAN DESIGN z~ 0 ~ ii~il ~ 0 ~ ~ / ~ ~ 1/2, SW I/4, NE 1/4, NE 1/4, SE 1/4,% / ' ~ I ~ ~o¢ ~ ~- ~<-. Oo~t .. '1 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: ,t ~,/~ WAS GROUND WATER ENCOUNTERED7 5 6 7 8 9 10 11 12 13 14 15 16- 17- 18- 19- 20- iF YES, AT WHAT -- O DEPTH? ~ oog~ ,o W,~r A,,r~ ,t x el,/9 C Monitoring? Date: Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER / /.~ ~'~' TEST RUN BETWEEN __ FT AND FT COMMENTS CERTIFY THAT THIS TEST WAS PERFORMED IN 17034 Eagle Ri~r L~p Road No. 2~ ~ ~ ' 72-008 (Rev. 4/~) I,~,1 DEPARTMENT OF HEALTH & HUMAN SERVICES ~ 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION:W~/~ ,S~ '/~, ~, ~b¢/~ lC& '/~Townsh~p, Range, Sechon. 1 2 3 4- 5 6 7 8 9 10 11 WAS GROUND WATER /~' ~ ENCOUNTERED? IF YES. AT WHAT ~- DEPTH? ~ pO E ~nitorin§? Dale: SLOPE SITE PLAN 13- 14- 15- 16- 17- 18- 19- 20- Gross Net Depth to Net Reading Date Time Time Water Drop Il ', $ ¢ j i~l~,...~ ¢1'~/~~' 'i~' "" 3' ~ 't'/~" PERCOLATION RATE TEST RUN BETWEEN __ (minutes/inch) PERC HOLE DIAMETER -- FTAND ~, ~/3. FT COMMENTS $ & $ EN$1NI~ERIN$ ,~r~'/ ~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN PERFORMED BY: ~."'C.~-~ -'"&~jJ,~ ;;~a ~ ~ ~0, ~ ACCORDANCE WIT~[e~,~e~L GUIDELIN ES I. EFFECT ON THIS DATE. DATE: ~ // / ~ g 72-008 (Rev, 4/85) ROBERTC.COWAN, P.E. ON-SITE WASTEWATER DISPOSAL SYSTEM ROBERTA.SHAFER,PE. CONSTRUCTION rMACTICEs and CIVIL ENGINEERS MATERIAL SPECIFICATIONS (907)694-2979 FAX(907)694-1211 (REFERENCE: W 1/2, SE 1/4, NE 1/4, NE 1/4, SE 1/4, NEAL,HALffNOPoTY Sec. 30, T12N, R2W OVA APPRS June 18, 1996 SEWER d WATER LWNEIRENSM 1. The scope of this project includes the installation of a 1000 gallon septic tank and a five foot wide drainfield to serve the proposed three bedroom residence located on the referenced property. SEWERa WATEfl l6PECTION 2. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal ENGINEERINGSrLOES Regulations. ANDREPORTS 3. The contractor shall be responsible for obtaining any necessary underground utility locates. WELL INSPECTION APLOW TEST 4. Unless specifically agreed otherwise,the property owner shall be responsible for final grading areas subsequently depressed from soil settling. SITEPLANS 5. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the FKADDESIGN Municipal Health Department. SEPTIC TANK INSTALLATION: SOL TEST 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. MST 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a STRUCTURAL& minimum of 12 inches above final grade. MECN CAL R6PECOONS ONSITE WASTEWATER DEPOSAL SYSTEM OESIGN 17034 NORTH EAGLE RNER LOOP • SURE 204 • EAGLE RIVER, ALASKA 99577 Page Two W 1/2, SE 1/4, NE 1/4, NE 1/4, SE 1/4, Sec. 30, T12N, R2W June 18, 1996 4. Septic tanks installed with less than 4 ft. of cover shall be insulated. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed -up) before gravel (sewer rock) placement. 2. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Mage Three W 1/2, SE 1/4, NE 1/4, NE 1/4, SE 1/4, Sec. 30, T12N, R2W June 18, 1996 5. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a.depression after settling. MINIMUM MATERIAL SPECIFICATIONS: 1. Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Tyne of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the 8200 sieve. 7. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. Page Four W 1/2, SE 1/4, NE 1/4, NE 1/4, SE 1/4, Sec. 30, T12N, R2W June 18, 1996 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. Page Five W 1/2, SE 1/4, BE 1/4, BE 1/4, SE 1/4, Sec. 30, T12N, R2W June 18, 1996 S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER PROPERTY: T12N R2W SECTION 30 W2 SE4 NE4 NE4 SE4 PERMIT#: SW960174 ENGINEER: WILLIAM L. ULICH PE# CE -4766 OWNER: GEORGE STEVENS WORK PH# 786-6700 TO: JAMES CROSS, P.E. PROGRAM MANAGER, ON SITE WATER QUALITY 825 "L" STREET,RM.502 FROM: GEORGE STEVENS REFERENCE: CONFERENCE / MEETING OF 10-8-97 THE FOLLOWING ITEMS,ALTHOUGH DIFFER FROM THE APPROVED DESIGN,MEETS WITH YOUR APPROVAL. RECEIVED OCT 14 1997 Municipality of Anchorage Dept. Health & Human Services 1. DESIGN A. 1. INSTALLED BED SYSTEM 2. SAND FILTER 8 FEET DEEP 3. INSTALLED EFFECTIVE DEPTH OF 1.5 FT. OF SEWER ROCK 10\9\97 IN ACCORDANCE WITH THESE ITEMS, I WILL BE PROCEEDING TO ADDRESS ADDITIONAL ITEMS OF CONCERN WHICH YOU HAVE PROVIDED. THANK YOU FOR YOUR TIME AND PATIENCE rTZEVENS �3 .off. MUNICIPALITY OF ANCHORAGE .. DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW960174 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:STEVENS GEORGE D OWNER PAGE 1 OF DATE ISSUED: 7/09/9.6---- EXPIRATION DATE. 7/09/97 ADDRESS:4500 DIPLOMACY DRIVE, SUITE 43 ANCHORAGE, AK. 99508 PARCEL ID:02102250 `LEGAL DESCRIPTION: T12N R2W SEC 30 W2SE4NE4NE4SE4 LLOT SIZE: 54450 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 L'1'11IS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: L1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL L REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING. I WEATHER MUST BE EITHER: I•. A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: 1.) THE BOTTOM OF THE SEWER ROCK MUST BE A MINIMUM OF 6 FT. ABOVE BEDROCK (FRACTURED OR WEATHERED BEDROCK). . 2.) INSTALL AN IMPERMEABLE MEMBRANE AROUND PERIMETER OF SAND LAYER TO ENSURE THE DOWNWARD MOVEMENT OF EFFLUENT. _ 3.) THE SAND USED AS A FILTER LAYER MUST BE A CLEAN COARSE SAND FROM AN ADEC APPROVED SOURCE, OR THERE MUST BE A SIEVE ANALYSIS TAKEN SHOWING THAT THE S D MEETS CURRENT -+ MOA/DHHS REQUIREME T RECEIVED BY: DATE: % A C ISSUED BY: L� DATE • 0-469 bL i^ .� Alunieipality of Anehorage • 7 Department of Health and Human Services 625 "L" Street Rick Mystrom. P.O.Box 196650 Anchorage, Alaska 99519-6650 ." Mayor 907-343-4744 , Property: T12N R2W Section 30 W2 SE4 NE4 NE4 SE4 Permit # : SW960174 ,Engineet: William L Ulich PE# CE -4766 I Owner: George Stevens work phone 786-6711 ,. inspections: 9/25/97 afternoon D. Mears & A. Kim i 10/2/97 9:20-9:40 am D. Mears & J. Cross " The As -Built submitted to DHHS has the following discrepancies, deficiencies and violations: 1. Desien a) installed system differs significantly from approved design. 15.65.150-F-6 i) Installed system is a bed, approved system was a double trench. ii) Installed sand filter is 8 feet deep, approved filter was 4 feet deep. I iii) Installed effective depth is 1.5 feet, approved effective depth was 6 inches. r• b) The absorption area calculations were based on the native soil percolation rate of 5.3 and 2 I minutes/inch. The percolation rate of the sand used is unknown. 15.65.060-1-3 c) The distance between the distribution lines is listed as 10 feet and the maximum allowed for a bed is 6 feet. 15.65.060-H-5 2. Installation,,- a) nstallation,/a) The system is owner installed. Permission was not given by DHHS for this. He was neither information submitted attesting to his qualifications, nor is he an approved excavator. 15.65.035-A. From site visit, owner states he was a project manager for many years and he has photos and f' receipts of the installation. ! b) Native soil was excavated to bedrock, the soil layer under the absorption area must be 2 feet thick. 15.65.060-H-1. The accepting stratum must be native soil. 15.65.060-1-2 c) The sand used in the filter layer is not stated as coming from an approved source, nor is a sieve analysis given as per permit special provisions. .- d) The side slope of the mound is steeper than 33% 15.65.060-1-4 — e) The 4 standpipes in the bed are all monitoring tubes. The 2 pipes at the far end of the field from .. the tank need to be cleanouts. 15.65.060-E-12 l T — 3. -W&U a) The well on the site is only 93.4 feet from the first cleanout of the septic tank. b) No well log was submitted with the As -Built. f r— 4. As -Built a) Separation distances are not completely filled in r, ' b) Well information is missing ✓ c) Soil rating information is missing r t d) Total absorption area is missing --Gpench mark location is missing, however there is no evidence that a survey was even completed. r f) Total depth of system from original grade is listed as 10 feet, however 2 soils logs recorded bedrock at 4 and 6 feet from grade. g) Depth to pipe bottom from original grade is listed as 7 feet. This does not agree with the submitted r' drawing & stated excavation depth. With an excavation of 10 feet and a depth to pipe bottom from original grade of 7 feet, there would only be a 3 foot separation between the bottom of the pipe and the bottom of the system. 5. Site plan 15.65.150-F-2 a) Not surveyed r, 1` b) No property lines c) Neighboring wells & systems not shown id) North arrow missing e) Not to scale r' 6. Cross Section 15.65.150-F-2 t a) Not surveyed b) Not to scale r. TO: I I r i t r- 1 E i" JAMES CROSS, P.E. PROGRAM MANAGER, ON SITE WATER QUALITY 825 "L" STREET, RM.502 P.O, BOX 196650 ANCHORAGE, AK 99519-6650 RE' PROPERTY: T12N R2W SECTION 30 W2 SE4 NE4 NE4 SE4 PERMIT#: SW960174 OWNER: GEORGE STEVENS SUBJECT: AS -BUILT SUBMITTAL DISCREPANCY REPORT My firm has been retained to investigate and review the subject referenced above "As Built" descrepancy report issued from your office. I have reviewed the following discrepancies, deficiencies, and violations referenced in your letter to Gerorge Stevens, and the comments prepared by Mr. Stevens that define and clarify DHHS concerns regarding construction of his septic absorbtion field and Water Well placement. I concurr with Air. Stevens's design and action plan to correct the noted deficiencies. It should be noted that the absorbtion sand bed is an ehancemeat to the MOA design standard. Also, the additional four feet of approved sand placed in the absorbtion field exceeds all MOA/DEC requirements for accepting soil. If you have any further questions please contact me. Yours truly, Richard L. Boysen, P.E. P.O. Box 110732 Anchorage, Alasaka 99511 VVV r I I r n i r i TYPICAL WIDE DRAINFIELD INSTALLATION (FIVE WIDE) t E h cs*& o d I* to 4• Mom mund4110n, . -r �Splk Ynk 1 'V CI44noULL �� e•ptle hnk rW Goad PL /, drtNntNdd. �� t7e.mw a ^' MpinMnq o) �. tlrelnMW ... (SIDE vi" r P40—Nd Alpe Yb InN (P•r/4. down( A Onrel bed rr aNn. • 4r aw+ not pau so w� "1� �% CIMn01� 11 aM Of Is N,1» pMomM— wl en,+l d"M and I ewllOulkWed 60 Mnm4wd TYPICAL.WIDE DRAINFIELD DESIGN (FIVE WIDE) (eMD VIEYY) $W$M mowgy b Nwvn OmYwge _ r&MY Nom droWW& NATIVE 6OtL BACKM /,1 . / 121'wdrwmlrn-mu41W / - .. - d�nad.wesN«ewar-1•� ., ' - .. r•�•+L• •• ..� '. . 4_P•dlMalod - .. ...t—_ •t_• •, (Paff dowel. _ .. ..•.,.-.-- .. Vol 0. Now lune mwrmlm of awo (tl Nwl e1 " aru tlrau l41ow Mwnead - TTi i SAMPLE WIDE DRAINFIELD CALCULATIONS ISO So.Fl m•a•^om x Number of Bedrooms AD12ticallon Rate ff3ellonlOevBe F[ 1 • x Reduction Factor a Length S.(Width) - . NOTE: Reduction factor shown on Page 20 of Septic Tank Manual and on reverse side of this page. Example: 4 Bedrooms - Percolation Test Rate of 7 minut*Mneh • soil strata from 4' to 11% Use 36 Inches " of sewer rock • R.F. ■ 0.58 (from table on reverse side of this page) 15D 4tr, Ft )9edroom x 4 Bedrooms Length a .a 6pOf5e FL fProm table on reveres aide of this be ) x .58 a 87 Feet Use two (2) drainfie(ds, each 44 feet long, 5 feet wide, 36 Inches ofsewer rock below perforated pipe. The dralnfields must be a minimum of 10' aparL (Maximum length of too 1001) Use application rate shown on reverse side of this page. " A gravel depth of 36 Inches would piece the bottomof the absorption field at a total depth of 7 feet. This total depth also sattsfiea requirement of a mMfmum of 21set of accepting soil below the absorption field bottom r rPROPERTY: T12N R2W SECTION 30 W2 SE4 NE4 NE4 SE4 PERMIT#: SW960174 r ENGINEER: WILLIAM L. ULICH PE# CE -4766 OWNER: GEORGE STEVENS WORK PH# 786-6700 j TO: JAMES CROSS, P.E. 10\9\97 11 PROGRAM MANAGER, r, ON SITE WATER QUALITY 825 "L" STREET,RM.502 I FROM: GEORGE STEVENS IF- REFERENCE: CONFERENCE / MEETING OF 10-8-97 THE FOLLOWING ITEMS LISTED ARE ADDITIONAL CONCERN'S IH WE HADA GRED THAT I WOULD DELIVER TO YOU BY OC OBEWH R 22,C 1997. I. DESIGN i B. ABSORPTION AREA, HAS EXCEEDED THE SQ. FOOTAGE REQUIRED FOR A r THREE BEDROOM RESIDENCE, TOTAL AREA 15X45 =675 SQ. FT. THE PERCOLATION RATE OF THE SAND,PLEASE REVIEW ANCHORAGE TEST LAB REPORTS AND SUBMITTIALS PROVIDED BY ANCHORAGE SAND AND GRAVEL. r C. DISTANCE BETWEEN THE DISRIBUTION LINES. I PURPOSE TO OPEN THE CENTER OF THE ABSORPTION FIELD AND ADD AN ADDITIONAL LINE. .- 2. INSTALLATION l A. FIRST I MUST MAKE IT CLEAR AND EXPLICIT THAT I AM EMPLOYED BY THE UNIVERSITY OF ALASKA ,THE POSITION WHICH I HAVE HELD FOR THE PAST FIVE YEARS IS THAT OF A CONTRACT MANAGER\ CONSTRUCTION MANAGER. YOUR COMENTS IN ITEM "A" WERE TAKEN COMPLEATY OUT CONTEXT. B. NATIVE SOIL, THE ABSORPTION AREA OF 675 SQ. FT., WAS EXCAVATED �- TO ACOMADATE FOR THE EIGHT FT. DEEP SAND BED. THE STRATUM BENETH THE SAND FILTER CONTINUES TO BE NATIVE SOIL, CONSISTING OF SANDY SILT AND SHATTERED ROCK. WITH THE ADDITIONAL FOUR FT.OF SAND BED THAT r r r l HAS BEEN INSTALLED I BELIEVE THAT 1 HAVE ACHIEVED A MUCH SUPPERIOR FILLTERING SYSTEM THAN ORIGANIALY DESIGNED. ( SEE ENGNEERING REPORT) r C. PLEASE REVIEW ANCHORAGE TEST LAB'S REPORT'S ,AND SUBMITTIALS APPROVED BY THE MUNICIPALITY OF ANCHORAGE. ALL SAND USED,WAS r PROVIDED BY ANCHORAGE SAND AND GRAVEL, PLEASE REVIEW RECEIPT'S PROVIDED. I D. THE SIDE SLOPE OF THE MOUND WILL BE CORRECTED UPON FINAL GRADE COMPLETION, E. UPON OPENING THE ABSORPTION FIELD ,I WILL CORRECT THIS BY ADDING THREE CLEANOUT'S. 3. WELL 17 A. AFTER CONFIRMING THE SEPERATION DISTANCE, AND IF NEEDED MY WELL DRILLER WILL PROCEED TO DRILL A NEW WELL. r^ B. WELL LOG IS SUBMITTED WITH THIS PACKAGE. 4. AS-BUILT'S i . A -G THESE ITEMS WILL BE ADDRESED WITH THE FINIAL AS BUILT'S. C SITE PLANS AND CROSS SECTION WILL BE COMPLETED UPON COMPLETION OF i ORECTED SYSTEM. r r r OCT -10-97 FRI 07:08 MUM FAX NO, 9073442844 P.07 Anchorage sand F Gravel 06/18/96 Aggregate Blend AGGREGATE BLEND -- MANUAL Specification ID : MOA FILTER ROCK Blend ID MOA FILTER ROCK ------------------------------------------------------------------- Sieve Low High 4 Pass Aggregate Pct --------------------------------------------------------------- 2 • ^ 100.0 100.0 100.0 MOA FILTER ROCK 100.0 1-1/2 n 95.0 100.0 99.9 3/4 " - 20.0 8.6 3/8 " - 5.0 0.2 cost - Fineness modulus 7.91 Gradation of VA FILTER ROCK LOA........................ 1 ♦y ' �y % 75.0 .........}....!y.,+�.................}......................... ♦ ,y S.. ....... ...........,.. ......... ... S ., ........ .......... y.... 1♦. ................................ s' i•s/:� �/4� 3/$' Sieve OCT -10-97 FRI 07:07 AS&G/ABI Anchorage Sand & Gravel Aggregate Suitability April 3, 1996 Pale 2 Aggregate Suitability Values FAX NO. 9073442844 P. 06 PROPERTY TEST RESULT LATEST YEAR OF TESTING Organic Impurities Within Acceptable Limits 1996 Sodium Sulfate Soundness (Loss in 5 cycles) Coarse Aggregate: 1.0% Fine Aggregate: 2.6% 1996 Magnesium Sulfate Soundness (Loss in 5 cycles) Coarse Aggregate: 1.6% Fine Aggregate: 4.0% 1996 Las Angles Abrasion (Loss in 500 revolutions) 13% 1996 Clay Lumps and Friable Particles Coarse Aggregate: 0.170 Fine Aggregate: 0.0% 1996 Potential Reactivity Innocuous 1992 Degradation Value 60 1994 If you have any questions regarding the mix design procedures or the interpretation of the data, please call me. Sincerely, ALASKA TESTLAB a.� � j� OF A(g1�D Howard K. Weston, P.E. ',�P� sj I+ Technical Director �;� faeri t *#Ap B.,.md i weem CE W2 OCT -10-97 FRI 07:07 AS&G/ABI ALASKA., —� T E 6 T L A B A Division of COWL, Incorporated W.O. A25862 April 3, 1996 Anchorage Sand & Gravel 1040 O'Malley Road Anchorage, Alaska 99515 - Attention: Mr. Wes Vander Martin Subject: 1996 Aggregate Suitability for Poi4Q Cement Concrete and Hot Mix Asphalt .. Dear Mr. Vander Martin FAX NO. 9073442844 P.05 .•� w� AASHTO ACCREDITED CONSTRUCTION MATERIALS TESTLYG , LABORATORY You delivered aggregate samples to us on February 12, 1996. Selected suitability tests were performed on the aggregate. Alaska Testlab has records of aggregate suitability test results for your r. aggregate which date back to 1976. Due to this long history of aggregate performance, the full range of aggregate suitability tests are not performed every year. The aggregate suitability values r' are tabulated below with the latest year of testing identified. The test standards followed during the 7 laboratory test program are listed below. 7 ASTM C40, "Organic Impurities in Fine Aggregates for Concrete" ASTM C88, "Soundness of Aggregates by Use of Sodium Sulfate or Magnesium Sulfate' r, ASTM C131. "Resistance to Degradation of Small -Size Coarse Aggregate by Abrasion iand Impact in the -Los Angeles Machine" ASTM C142, "Clay Lumps and Frable Particles in Aggregates" r. ASTM 0289. "Potential Reactivity of Aggregates (Chemical Method)" ,. ATM T-13, "Degradation Value of Aggregates" tom' 4010 5 STREET 0 ANCHORAGE • ALASKA 0 99503-5999 6 907/362.2000 6 FAX 907/663-3063 A OCT -10-97 FRI 07:07 AS&G/ABI ALASKA A Division of DOWL, Incorporated Anchorage Sand & Caravel 1040 O'Malley Road Anchorage, Alaska 99515 ,. Attention: Mr. Subject: Particle -Size Analysis 1996 Misc Aggregate Testing FAX NO. 9073442844 P.04 4+ AASATO ACCREDITED CONSTRUCTION - MATERIALS TESTING • 1.11 • ' LABORATORY W.U.#A26709 April 29, 1996 Dear Mr. : The particle -size distribution of your soil was measured in the laboratory. The published methods for this test are: • ASTM C 117, "Material Finer Than 75 -lira (No.200) Sieve In Mineral Aggregates by W ashina " • ASTM C 136, "Sieve Analysis of Fine and Come Aggregates;" • ASTM D 422, ?article Size -Analysis of Soils' • AASHTO T-11. "Material finer Than 75•µm Sieve in Mineral A;;regatn; • AASHTO T-27, "Sieve Analysis of Fine and Coarse Aggregates"; • AASHTO T-30, "Mechanical Analysis of Extracted AggTgate," • AASHTO T -88, "particle Size Analysis of Soils." and • AK DOT/PF ATM T-7, "Sieve Analysis of Fine and Coarse A88reitates." Alaska Testlab's standard procedure is in conformance with these standards, with the following r descriptions: • The coarse fraction of nonextracted soils is not washed unless the coarse particles appear to be slgnlficantly coated with fines; r' • The fine f action of the soil is always washed; • The plus 3 -inch fractinn is not routinely included in the test due to the large sample mass required for a representative sample: The estimated percentage of plus 3 inch material in the sample is shown on the test report; and .- • The mass of the coarse and fine tat fractions we reported. The soil is classified in accordance with ASTM D 2487, "Classification of Soils for Engineering Purposes (Unified Soil Classification System)." The frost classification is identified in accordance with Corps of Engineers and Municipality of Anchorage (MOA) proccdurss. The test results are attached. If you have any questions regarding the test procedures or the results, please call me. Sincerely, ALASKA TESTLAB > Howard K. Weston, P.E. Technical Director �. 4040 3 STREET 0 ANCHORAGE • ALASKA • 99603-6999 • 907/460-8000 FAX 907/499-3g6n1 OCT-10-97 FR1 07:07 AS&G/ABI FAX N0. 9073442844 P.03 a sutrnidiary of Alaska Bask kidustries r AS&L �- ANoWORAGE SAND MW GRAVEL COSY INC. Road * Anchorage.A March 31, 11997 ." Re: Sewer Filter Rock 2" Minus 7 To Whom It May Concern: The Sewer Filter Rock 2" Minus supplied by Anchorage Sand and Gravel Co., r" Inc. (AS&G) from our Klatt Road Terminal meets specifications designated below. The i . aggregate for Sewer Filter Rock 2" Minus consists of natural aggregate washed and processed to assure suitable particle shape and gradation. Aggregate for Sewer Filter Rock 2" Minus is graded within the following limits: .. U.S. Standard Percent by Weight Sieve Passino 2" 100 11/2" 90-100 1" 30-50 3/4" 0-10 .. 1M„ 0-5 1 have attached a copy of AS&G's Laboratory's test analysis for you, and Alaska Test Lab's 1994 Aggregate Suitability test results. If you have any questions or if I can be of any service, please call me. Sincerely, ANCHO G RAVEL CO., INC. C. Earl Polen Aggregate Sales Manager r OCT -10-97 FRI 07:06 AS&G/ABI FAX NO. 9073442844 P.02 a subsidiary of ALulm Basic Industries 0 ANCHORAGE SAND sa land GRAVEL r O INC.IC i March 31, 1997 r Re: Bedding Aggregate #4 Minus To Whom It May Concern: The Badding Aggregate #4 Minus supplied by Anchorage Sand and Gravel Co., Inc. (AS&G) from our Klatt Road Terminal meets specifications designated below. The aggregate for Bedding Aggregate #4 Minus consists of natural aggregate washed and r processed to assure suitable particle shape and gradation. Aggregate for Bedding Aggregate #4 Minus is graded within the following limits: U.S. Standard Percent by Weight SSievaye Passing 318 100 #4 70-100 #8 0-35 .. #16 0-10 #30 0-s I have attached a copy of AS&G's Laboratory's test analysis for you, and Alaska Test Lab's 1994 Aggregate Sultablltty test results. If you have any questions or If I can be of any service, please call me. Sincerely, ANCHORAG AND RAVEL CO., INC. C. Earl Polen Aggregate Sales Manager i ro r OCT -10-97 FRI 07:06 AS(EUM FAX N0, 9073442644 P.01 AS&G a division ofAlasKa Basic Indusules �- Anchorage Sand and Gravel Co., Inc. 1040 C+Maky Road, Anchorage. Alaeka 89515 ,I 'Jett Art -We Denver' _ 11 l ' •• z _ ., FAX Transmittal Sheet 'FAX (907) 344-n" Phono (907) 3493333 I Submittals for Sewer Filter Rock & Bedding Aggregate #4 Minus. j Thanks. Earl t I► - 1 r rr I " Number of pages sent ,. FROM: C. Ead Polen If you do not receive ail pages. please call sender ASAP (90T) 349-3333. ANCHORAGE SAND and GRAVEL CO.9 INC. a subsidiary of Alaska Basic Industries 1040 O'Malley Road, Anchorage, Alaska 99515 349333 SCALEHOUSE- 267-5140 DELIVERY ADDRESS GLEN ALPS GEORGE STEPHANS 440-6282 SPECIAL INSTRUCTIONSLOT DELIVERIES INSIDE CURB LIE AND ON THE LOT AT CUSTOMER'S RISK ONLY AND ACCEPT NO RE- SPONSIBILITY WHATSOEVER FOR DAMAGE RESULTING FROM SUCH DELMERES. DRIVER ON OFF F-] 761390 COST PO NO COST JOB NO CONTRACT NO TICKET NO CASH 61390 FOB PLANT F-1 FOB JOB a FOB PLANT • HAUL ING Te 16x31 TCUA Mm TRUCKER MYLES BOEHMER 500 MAVW ARRIVE AT JOB QUANTITY ORDERED QUANTITY DELIVERED QUANTITY TO 00 DEPART 0.00 670.10 —670.10 JOB LOAD NO NET WT 77 14.9100 STAND TIME r DESCRIPTION ORDER No SEWER ROCK 2 IN MINUS DEL CASH IN PRICE fftm!�c MAUL CHO BUB TOTAL TAK DRANO TOTAL TRIP63.91 86.25 350.16 0.00 350.16 TIME PRIVATE WEIGHMASTER I., TRw JEANNETTE99ANDRAIMICHELLE oeP r DRIVER f' RECEIVED BY��`���1 I, r P- DELIVERY ADDRESS GEORGE GLEN SPECIAL INSTRUCTIONS :AS - ANCHORAGE SAND and GRAVEL CO., INC. a subsidiary of Alaska Basic Industries 1040 O'Malley Road, Anchorage, Alaska 99515 349-3333 SCALE HOUSE - 267-5140 DRIVER ON WE MAKE DELIVERIES INSIDE CUR! LITE AND ON THE LOT AT CUSTOMER'S RISK ONLY AND ACCEPT NO RE- SPONSISILRY WHATSOEVER FOR DAMAGE RESULTING FROM SUCH DELIVERIES. El OFF ❑ 760146 COST PO NO CUST Jos NO CONTRACT NO TICKET NO K+ CASH 6014E FOB PLANTElFOB JOB © FOB PLANT • HAULING 1:1 OUST 13153 RomTRUCKER ZONE ARRIVE 3 & A ENT 5 000 MAVW AT JOB QUANTITY ORDERED QUANTITY DELIVEREDQUANTITY TO GO 0.00 82.85 —82.85 DEPART JOB LOAD NO NET WT 7 13.7800 iO ° ORDER NO HDESCRIPTION BEDDING AGO #4 MINUS DEL CASH IN ErpRICE HAUL CHO BUB TOTAL TAX GRAND TOTAL TRIP 173.63 0.00 173.63 0.00 173.63 TIME PRIVATE WEIGHMASTTRIPE SANDRA LLY R MICHELLE EPU Y MILES 7 DRIVER RECEIVED BY-L`:::�1 DELIVERY ADDRESS GEORGE STEVENS G, L 786-6711 SPECIAL INSTRUCTIONS AS&Cw;e,44 ANCHORAGE SAND and GRAVEL CO., INC. e subsidiary of Alaska Basic Industries 1040 O'Malley Road, Anchorage, Alaska 99515 349333 SCALEHOUSE- 267-5140 DRIVER ON WE MAKE DELIVERIES INSIDE CURB LOW AND ON THE LOT AT CUSTOMER'S RISK ONLY AND ACCEPT NO RE- SPONSISILITY WHATSOEVER FOR DAMAGE RESULTING 0 FROM SUCH F—] 760093 760093 OUST PO NO OUST JOB NO CONTRACT NO I TICKET NO CASH 0093 FOB PLANT ❑ FOB JOB © FOB PLANT .HAULING ElOOUATE TI 12145 TRUCKER ZONE ARRIVE AWM 9 & A ENT 5 000 MAVW BMW AT Joe QUANTITY ORDERED QUANTITY DELIVERED QUANTITY TO 00 DEPART 0.00 69.07 —69.07 JOB LOAD NO NET WT STAND 6 13.0100 TUE TME C,. DESCRIPTION ORDER NO BEDDING AGG 04 MINUS DEL CASH N - NET PRICE HAUL CHO SUS TOTAL TAX GRAND TOTAL TRIP 60 '•' 163.93 0.00 163.93 0.00 163.93 PRIVATE WEIGNMA TER SANDRAs OLLY� & MICHELLE TRIP MILES urr RECEIVED B ,f - - - AS Wjot 4* ANCHORAGE SAND and GRAVEL CO., INC. B subsidiary of Alaska Basic Industries 1040 O'Malley Road, Anchorage, Alaska 99515 349-3333 SCALE HOUSE - 267-5140 DELIVERY ADDRESS LGEORGE STEVENS GLEN ALPS 786-6711 J WE MAKE DELIVERIES INSIDE CURB LINE AND ON THE SPECIAL INSTRUCTIONS LOT AT CUSTOMER'S RISK ONLY AND ACCEPT NO RE- SPONSNRLRY WHATSOEVER FOR DAMAGE RESULTING FROM SUCH DELIVERIES. O O O �� DRIVER ON ❑ OFF COST FO NO CURT JOB NO CONTRACT NO TICKET NO 60027 CASH TIME LANT ❑ FOB JOB ® FOB PLANT • HAULING ❑ T 11 123 TRUCKER ZONE 5 000 MAVw ;OUANOTIBrY ARRIVE AT JOB S i A ENT DEPART JOB ORDERED QUANTITY DELIVERED QUANTITY TO 00 -44.34 0, 44.34 LOAD NO NET WT 14.7700 STAND 4 DESCRIPTION ORDER NO AGG N4 MINUS DEL CASH TIME IN BEDDING PMC( !. < NET PRICE HAUL CMO 0.00 BUB TOTAL 186.10 TAX GRAND TOTAL 0.00 186.10 T� 186.10 ,SANDRA DRIVER RECEIVED By MILES I r AS&Gs� I ANCHORAGE SAND and GRAVEL CO., INC. a subsidiary of Alaska Basic Industries 1040 O'Malley Road, Anchorage. Alaska 99515 349333 SCALE HOUSE - 267-5140 wm��2_ ; "I"', DELIVERY ADDRESS GEORGE STEVENS GLEN ALPS 786-6711 WE MAKE DELIVERIES INSIDE CURB LME AND ON THE SPECIAL INSTRUCTIONS LOT AT CUSTOMEWS RISK ONLY AND ACCEPT NO RE- SPONSIBILITY WHATSOEVER FOR DAMAGE RESULTING FROM SUCH DELIVERIES. ABOVE HILLSIDE DR DRIVER ON ❑ OFF F-1 759926 [u4T P NO CUST JOB NO CONTRACT NO TICKET NO r000c FOB PLANT F-1FOBJOB © FOB PLANT • HAULING ❑ OUT 09110 TRUCKER - ZONE ARRIVE S bAENT 5 000 MAVW AT JOB QUANTITY ORDERED QUANTITY DELIVERED QUANTITY TO 00 —1•.1. I4 JOB 0:00 15.14 NET WT STAND LOAD No 13. 9300 TwE DESCRIPTKIN ORDER NO TIME BEDDING AGG 04 MINUS DEL CASH IN NET PRICE HAUL CHO BUS TOTAL TAX GRAND TOTAL TRIP 175.77 0.00 175.77 0.00 175.77 TME TRIP PRIVATE WEIOHMASTf jNLES RECEIVED DRIVER 7 t • 1 s v. DELIVERY ADDRESS GEORGE GLEN L 786-6711 SPECIAL INSTRUCTIONS AS&G os ANCHORAGE SAND and GRAVEL CO.j INC. a subsidiary of Alaska Basic Industries 1040 O'Malley Road, Anchorage, Alaska 99515 349-3333 SCALEHOUSE- 267-5140 DRIVER ON WE MAKE DELIVERIES INSIDE CURB LINE AND ON THE LOT AT CUSTOMER'S RISK ONLY AND ACCEPT NO FIE- SPONSIINLITY WHATSOEVER FOR DAMAGE RESULTING FROM SUCH DELIVERIES. ♦ 7 6 O O 31 EOff F-1 DRIVER RECEIVED BY 1 OUST PO NO COST JOB NO CONTRACT NO TICKET NO H CASTIME 60031 FOB PLANT ❑710BEil. FOB DLANT •HAULING O TRUC 20NE ARRIVEAG 4 000 MAVW AT JOB QUANTITY ORDEREDDELIVEREDQUANTITY TO 00 DEPART 0.00 56.06 -56.06 JOB LOAD NO NET VST STAND 5 11.7200 TEAS w DESCRIPTIONORDER NO MIND BEDDING AGO N4 MINUS DEL CASH 40._` .�.. NET PRICE 147.67 MAUL CHG 0.00 SUB TOTAL 147.67 TAX 0.00 GRAND TOTAL 147.67 TIM1EE 9 PRIVATE WEIGHM4&TfR SANDRA, LLYY ✓ S MICHELLE TRIP MILES DEPUTY DRIVER RECEIVED BY 1 r 1. ANCHORAGE SAND and GRAVEL CO., INC. r a subsidiary of Alaska Basic Industries I 1040 O'Malley Road, Anchorage, Alaska 99515 r, 349333 SCALE HOUSE - 267-5140 l DRIVER ON ❑ WE MAKE DELIVERIES INSIDE CURB LME AND ON THE LOT AT CUSTOMER'S RISK ONLY AND ACCEPT NO RE- SPONSIBILITY WHATSOEVER FOR DAMAGE RESULTING FROM ❑SUCH DELIVERIES. 759981 OLLYTSANDRA burr T,I wiles DRIVER RECEIVED CUST PO NO CUST JOB NO CONTRACT NOTKKET NO CASH 39981 =RDU FOB JOB ®FOB PLANT • HAULING F GOUT 10E21 ZONE ARRIVE A ENT 5 000 MAVW AT JOB QUANTITY DELIVERED OUANTTY TO GO DEPART 0.00 29.57 -29.57 JOB LOAD NO NET WT STAND TIME 3 14.4300 ORDER NO CASH DESCRIPTION BEDDING AGG 84 MINUS DEL TME IN Iwo NET PRICE HAUL CHO 0.00 BUB TOTAL 181.82 TAX 0.00 GRAND TOTAL 1 B 1. BE TRIP TIME OLLYTSANDRA burr T,I wiles DRIVER RECEIVED r I AS&C�m ANCHORAGE SAND and GRAVEL CO.T INC. p. a subsidiary of Alaska Basic Industries 10400'Malley Road, Anchorage, Alaska 99515 349-3333 SCALE HOUSE - 267-5140 i t n 7 '.,va v�F ,�. I. r �✓,, u DELIVERY ADDRESS GLEN GEORGE 440-6282 WE MAKE DELIVERIES INSIDE CURB LINE AND ON THE SPECIAL INSTRUCTIONS - LOT AT CUSTOMER'S RISK ONLY AND ACCEPT NO RE - J. ' SPONSISILITY WHATSOEVER FOR DAMAGE RESULTING FROM SUCH DELIVERMS. n DRIVER ON ❑ OFF F-1761086 I:HSFI NO COST JOS NO CONTRACT NO SK:KEZ DlO b FOB J09 FOB PLANT F El FOB PLANT ❑ HAULING OUT 13ES8 TRHORAGE REFUSE RUN 1 MAVW ARRIVE AT JOB QUANTITY ORDERED QUANTITY DELINg. 24 WANTITY TO 00 642.24 DEPART bb�4fLL'' JOB LOAD O NET WT 13. 7800 STAND TBE T°� IN FF5'O 0CK 2 IN MINUS DEL aroel�r H mmNET RIcE C4 HAUL D ��.23 SUB,T L 3:16 TAX 0.00 T T L GPD. TRIP TIME s.91 PRIVATE WEIGNMASTER HOLLY, JEANNETTE TRIP MILES DEPUTY DRIVER RECEIVED BY( L/ �J 1 ■ \ AS&G-mea* ANCHORAGE SAND and GRAVEL CO.9 INC. a subsidiary of Alaska Basic Industries 1040 O'Malley Road, Anchorage, Alaska 99515 349-3333 SCALE HOUSE - 267-5140 Rik 9. affil DELIVERY ADDRESS `vt �1G LGEORGE STEVENS GLEN ALPS SPECIAL INSTRUCTIONS J WE MAKE DELIVERIES INSIDE CURB AND ONTHE LOT AT CUSTOMER'S RISK ONLY ANDD A RE - ACCEPT NO RE- SPONSIBILITY WHATSOEVER FOR DAMAOE RESULTING FROM SUCH DELIVERIES. DRIVER ON OFF 760150 '� CUST PO NO COST JOB NO CONTRACT NO TICKET NO CASH 60150 FOB PLANT a FOB JOB © FOB PLANT •HAULING ❑ OUT 13E5a TRUCKER ZONE ARRIVE S d A ENT 5 00 MAVW AT JOB QUANTITY ORDERED QUANTITY DELIVERED QUANTITY TO 00 DEPART 0.00 37.00 —37.00 JOB LOAD NO NET WT STAND 13 7. 5000 TaAe DESCRIPTION ORDER NO HOURLY DELIVERY ED CASH IN NET PRICE HAUL CHG SUB TOTAL TAX GRAND TOTAL TRW 517.50 0.00 X47.50 0.00 517. 50 TIME PRIVATE WEIGHMASTER ti' TRIP SANDRA HOLLY MICHELLE UTY MILES r� RECEIVED BY-� P aYN� .y. L£ - wo 3I:88N W 9E.-L0--1Ilt S� m i a s sR m R A V P( pp F .y. L£ - wo 3I:88N W 9E.-L0--1Ilt ��1!� GE II4i Municipality of Anchorage =� Oh -Site Water and Wastewater Program (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 021-022-50 1. GENERAL INFORMATION Expiration Date: Complete legal description T12N, R2W, SEC 30 W2SE4NE4NE4SE4 Location (site address) 13315 GLEN ALPS DR, ANCHORAGE, AK 99516 Current Property owner(s) JEFF REGNART Day phone Mailing address Real Estate Agent 13315 GLEN ALPS DR, ANCHORAGE, AK 99516 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class . Well Public Water System WaiverNariance request for: Received by: IIm Day phone > gN COSA to be released to the engineer, unless otherwise requested by the engineer. COSAFee $ ,5-Z(0 Date of Payment 1116/16" (,k 9%q Receipt Number 1114 2- COSA # ©SC,t 5 A914' Date: Waiver Fee $ Date of Payment Receipt Number Waiver # TYPE OF WASTEWATER DISPOSAL: ® Individual ❑ Holding Tank ❑ ❑ Community ❑ ❑ Public Sewer ❑ Distance: n—' COSA to be released to the engineer, unless otherwise requested by the engineer. COSAFee $ ,5-Z(0 Date of Payment 1116/16" (,k 9%q Receipt Number 1114 2- COSA # ©SC,t 5 A914' Date: Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm MIKE N ANDERSON, P.E. Phone 727-8864 Address 4661 NATRONA AVE. Engineer's Printed Name MIKE N ANDERSON, PE Date 10/27/15 ° 49$U �tt�;�T o • ° rr 6. DSD SIGNATURE d +�t .. s System #1 Approved for � bedrooms. � .f r,ic�;A�t System #2 Approved for bedrooms. `u CE_416' Disapproved. Zt:0 M Conditional approval for bedrooms, with the following The Municipality of Anchora9106velopment Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory, Septic System Advisory, Arsenic Advisory Well Flow Advisory Other COSA blue sheet 10-10-12.doc - If more than 1 septic system is on the lot: COSA Checklist # of Structure served by ths sy iste_m _ Certificate of On -Site Systems Approval Checklist Legal Description: T12N, R2W. SEC 30 W2 SE4 NE4 NE4 SE4 Parcel ID: 021-022-50 A. WELL DATA Well type Private If A, B, or C provide PWSID # Date completed 81711997 Sanitary seal (Y/N) y "Ir Total depth .105 ft. Cased to X ft. FROM WELL LOG%(,6 Date of test 8MI997 Static water level 34 ft. Well production AS g.p.m, a4,4 , WATER SAMPLE RESULTS: Well Log (YIN) Wires properly protected (YIN) Y Casing height (above ground) Coliform Nem colonies/100 mL Nitrate 0.435 mg/L AT INSPECTION 1012912015 25 ft. 1.9 g.p.m. Arsenic: ND ug/L Date of sample: 1012112015 Collected by: Mike Anderson B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC l STEEL Tank size 1500 gal. Number of Compartments 2 Foundation cleanout (YIN) Y Depression over tank (Y/N) N Date installed 101712004 Cleanouts (Y/N) High water alarm (YIN) Y Date of pumping ADV LATEX• # 1 ah Pumper ADVANTEX- sa�pcattac� heet— C. ABSORPTION FIELD DATApow – Date installed 101712004 Soil rating (g.p.d./fe or fe/bdrm) 6.0 System type SHALLOW 5 WIDE Length 40 ft. Width 5 ft. Gravel below pipe 0.5 ft. Total depth +3T75 ft. Eff. absorption area 200+ ftz Monitoring tube Y Depression over field N Date of adequacy test 10121/2015 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 600+ gal. New depth 2 in. Elapsed Time: 24 hrs min. Final fluid depth 0 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) UNKNOWN If yes, give date D. LIFT STATION (Advantex system wl external pump basin, see maintenance sheet) Date installed 101712004 Size in gallons 15001pump basin Manhole/Access (YIN) Y "Pump on" level at TIMER "Pump off" level at TIMER High water alarm level at TIMER Datum PRESET . Cycles tested ** E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift .station on lot 100'+ Absorption field on lot 100'+ Public sewer main 754 Sewer /septic service line 50'+ Animal containment areas 1004 SEPTIC/HOLDING TANK ON LOT TO: Meets alarm & circuit requirements? On adjacent lots 1004 On adjacent lots 1001+ Public sewer manhole/cleanout 100'+ Holding tank 41A 7 S 'f- Manure/animal excrete storage areas 100'+ Building foundation 5'+ Propertyline 54 Absorption field 5'+ Water main 100'+ Water service line 104 Surface water 100'+ Wells on adjacent lots 100'+ ABSORPTION FIELD ON LOT TO: Propertyline 5'+WAIVERONMLE Building foundation 10'+ Water main 104 Water Service line 104 Surface water 1004 Driveway, parking/vehicle storage 10'+ Curtain drain 50'+(None Known) Wells on adjacent lots 1001+ F. COMMENTS *well repairs and new water line completed by 907 Water Well Service see attached. ** see maintenance sheet G. ENGINEER'S CERTIFICATION `qE OF Al I certify that l have determined through field inspections and �'1P,••• review of Municipal records that the above systems are in h: conformance with MOA COSA guidelines in effect on this date. j * ,._R ••• ='ti /, /..:� .. ............A Engineer's Printed Name MIKE N. ANDERSON, PE %. P A• MICHAEL N. ANDERSON Date 01012712015 ��) y,F if fj qb �i PeorFsstn�'*`� COSA canary sheet 2.6-15.doc ZPA RESIDENTIAL & COMMERCIAL WATER AND WELL SERVICES ZSHR AND EMERGENCY SERVICES AVAILABLE FREE ESTIMATES John Nether n b 38 East Sl^Ava An A,m"Alaska907-239- 4y� ! g{/ dt q) �` +(p 43SPR 239— W 11/04/2015 To whom this may concern, This letter is in regards to the property located at T12N R2W SEC 30 W2SE4NE4NE4SE4 (13315 Glen Alps Rd) Extensive water line work was done at this location due to pre-existing damages to the water line causing constricted flow and constant freezing at the damage point and the well head pitless adapter. Upon excavation to find constricted spot and damage found it was decided replacing the entire line in a shorter run with internal heat trace would be more cast efficient than tracing back the old line to reveal other damaged areas. A new water line was installed from the well head at a depth of 3 feet from the eastern side of the well head to the south west corner of the building making entry to the utility room. Insulated board was added as another layer of protection. An internal heat trace was installed and runs the duration from the entry point to 10 feet down hole to prevent freezing of the line. 10 watts @ 120 -volt heat arctic trace was used. Manufacturer specs state that 2 inches of insulation or 2 feet of earth is a required insulator needed. The line was buried at or slightly beyond the 3 -foot depth depending on the shallow bedrock formation found shallow being the reason the line was originally buried and ultimately sustained damage. The heat trace has a G.F.C.I weatherproof adapter that is currently inside the home. The water line ultimately comes up out of the ground at the well casing and then makes its way down through a sanitary seal into the well and pump line. All exposed line is insulated. The exposed areas at the well head have 3 unions in place so that future servicing or replacement can be done without modification. The old pitless was plugged and sealed to prevent any entry points for contaminants. A flow test was also conducted on 10/29/2015 resulting in a well yield of 1.9 g.p.m. Total depth is 105 feet. S.W.L was found to be 24 feet 8 inches. Well has a new sanitary seal and the wires are encased in liqui tite conduit to allow flexibility for servicing. If there is further information required, please feel free to contact me at 907-230-1868 John Netherton ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT BETWEEN MUNICIPALITY OF ANCHORAGE AND DMAD L 4 Ha mft Q THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this ` Day of O6U r of 20 M , by and between DkJiD is -T1OMP5r30 herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY." In consideration of the mutual covenants contained herein, the parties to this Maintenance and Repair Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. Municipality grants permission to Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as t -z-4- AY, - located at (legal description). 1331-S (ln6,Ny R4, Rn4, e, pk i lb,� R 2%ii 10 2. Definitions. Alteration. Any change to the design or function of an AW WTS that includes the installation or removal of any parts, components or pieces not included in the original construction permit and design. Certificate of On -Site Systems Approval (COSA). An approval by the Municipality of existing water and wastewater disposal systems given at the time of property sale and title transfer in accordance with Anchorage Municipal Code (hereinafter, "AMC") 15.65. These approvals certify that the systems are adequate for the homes that they support and meet the codes that were in place at the time of system construction. Damage. Any man-made or natural change in a system that would inhibit the system from performing as designed. Maintenance and Repair. The scheduled and as needed replacement of existing parts, components and pieces of an AWWTS that were included in the original design which would allow the AWWTS to continue to perform as designed. Permit. An On -Site Wastewater Disposal Permit as required by AMC 15.65 to construct and operate an AWWTS. 3. Term. The teim of this Maintenance and Repair Agreement shall begin on the date of approval by the Municipality to operate the installed system or issuance of a COSA, and shall continue while the AWWTS is in use or is operational or until the property is sold or title is transferred by the owner and a new COSA is issued to the new owner or transferee of the property. 4. Alterations, Installation and Removal of Additional Equipment. Prior to performing any alterations to an AWWTS, the owner agrees to obtain an On-site Wastewater Disposal Permit from the Municipality in accordance with AMC 15.65. 5. Maintenance and Repairs. A. Throughout the term of this Maintenance and Repair Agreement, the Owner shall maintain their AWWTS in a satisfactory condition capable of producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. The owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the municipality and the manufacturer of the AWWTS for the entire term of the AWWTS. In addition, it shall be the responsibility of the Owner during the term of this Maintenance and Repair Agreement, and any renewals thereof, at the owner's sole expense, to pay for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement costs, and (S) inspection costs. B. Owner agrees to comply with all applicable ordinance, laws, regulations, rules and orders for the AWWTS. C. Upon request by the Municipality, the owner agrees to provide the Municipality a Written schedule of routine maintenance and repairs which have been performed on the system. When a record of maintenance is documented and maintained by the system vendor, the owner agrees to allow the Municipality access to this information. D. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60 for improper discharge. E. Owner agrees that only maintenance and repair personnel approved by the Municipality will inspect and make any necessary maintenance, repairs or permitted alterations to the system. F. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS upon 24 hours written notice. G. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. H. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. I. Owner agrees to provide and maintain a telephone connection to the AWWTS as required by the AWWTS approval. 6. Nonwaiver. The failure of either parry at any time to enforce a provision of this Maintenance and Repair Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Maintenance and Repair Agreement or any,part hereof, or the right of such party thereafter to enforce each and every provision hereof. 7. Amendment. A. This Maintenance and Repair Agreement shall only be amended, modified or changed by a writing, executed by authorized representatives of the parties, with the same formality that this Maintenance and Repair Agreement was executed with, and such writing shall be attached to this Maintenance and Repair Agreement as an amendment. B. For the purposes of any amendment modification or change to the terms and conditions of this agreement, the only authorized representatives of the parties are: a. Owner: to 1. I l bmmo b. Municipality: Director, Community Development or designated authority C. Any attempt to amend, modify, or change this contract by either an unauthorized representative or unauthorized means shall be void. 8. Jurisdiction: Choice of Law. Any civil action arising from this Maintenance and Repair Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Maintenance and Repair Agreement. 9. Severability. Any provisions of this Maintenance and Repair Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Maintenance and Repair Agreement. OWNER: Date: 1� 1 511015 _DN iO (print name) STATE OF ALASKA ) ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before me this L-�day of iVSiVPYYZ9rJ' 20_15, by bayou "L..:ildhTr' smn ............ / yam I1OTARY PUBLIC FOR ALASKA ta�� :� ' My Commission expires: Dry , : �d ��/ _ : KCITAXY MUNICIPALITY: By: (signature) Date: name) Title: Municipality of Anchorage On -Site Water & Wastewater Program (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 021-022-50 Expiration Date: J 1. GENERAL INFORMATION Complete legal description Location (site address) Current Property owner(s) Mailing address Real Estate Agent T12N R2W, SEC30, W2, SE4, NE4, NE4, SE4 13315 GLEN ALPS ROAD *ANCHORAGE, AK 99516 TAMERA OSWALD Day phone 440-1291 13315 GLEN ALPS ROAD *ANCHORAGE, AK 99516 SHARI BOYD W/ PRUDENTIAL Day phone 2. TYPE OF DWELLING: Single Family (w/wo Al ❑ Duplex ❑ Multipl � Dwellings (Single Family and/or Duplex) 3. NUMBER OF 3EDROOMS: 4 4. TYPE OF W',TER SUPPLY: 762-5863 TYPE OF WASTEWATER DISPOSAL: Individll:l Well 0 Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Com Anity Class Well ❑ Community On-site ❑ Publ ;: Water System ❑ Public Sewer ❑ Received t /: </014 COSA to be re h .sed to the engineer, unless otherwise requested by the engineer. COSA Fe : $ C) Date of F iyment Receipt I umber__ COSA # OSc 131 y $ Date: iJ Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE V System #1 Approved for __V_— bedrooms. System #2 Approved for bedrooms. Disapproved. Phone 337-6179 Date 2 3 Conditional approval for bedrooms, with the following stipulations: Original Certificate Date: The Mur�cipality or Anchorage Develop, emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist ti Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other (Rev 11105) if more than 1 septic system is on the lot: COSA Checklist # _of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: T1 2N, R2W SEC30 W2 SE4 NE4 NE4 SE4 Parcel ID: 021-022-50 A. WELL DATA *CASED TO BEDROCK Well type PRIVATE If A, B, or C provide PWSID# N/A Date completed 8/7/97 Sanitary seal (YIN) YES Total depth 105 ft. Cased to *3 ft. FROM WELL LOG Date of test 8/7/97 Static water level 34 ft. Well Log (YIN) YES Wires properly protected (YIN) YES Casing height (above ground) 18+ in. AT INSPECTION 3/28/13 Well production 5 g.p.m. 1.26 — 9 -p.m -WATER SAMPLE RESULTS: Coliform D colonies/100 ml. NitrateA4ymgJL. Collected by: GEG Ltd Arsenic: W ug./L. Date of sample: 7_,3 , ADVANTEX SYSTEM B. SEPTICIHOLDING TANK DATA Tank Type/Material STEP/STEEL Date installed 10/7-8/04 Tank size 1500 gal. Number of Compartments E Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES Date of pumping N"' ql V Pumper S4=� ? { I� SP�L^�v� �o�- C. ABSORPTION FIELD DATA *BELOW EXISTING GRADE ADVANTEX SYSTEM Date installed 0/7-8/04 Soil rating (g.p.d. /ft 'or /bdrm 6_0 System type SHALLOW TRENCH Length 40 ft. Width ft. Gravel below pipe 0.5+ ft. Total depth *3.75+ ft. Eff. absorption area 200+ ft2 Monitoring tube YES Depression over field NO Date of adequacy test 4/4/13 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 0 in. Water added 2000gal. New depth 0 in. Elapsed Time: E min. Final fluid depth 0 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) -A)< KE: -S O" A -D i e4T - O Kd NONE Citi MoA If yes, give date - D. LIFT STATION *SEE ATTACHED MAINTENANCE REPORT Date installed 10/7-8/04 Size in gallons 1500/86 ManhoWAc cess (YM) YES "Pump on" level atTIMER 291n. "Pump off" level at TIMER/23.5in. High water alarm level at 46/56.75 in. Datum BOTTOM OF TANK Cycles tested * Meets alar & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tanknift station on lot 100'+ On adjacent lot: Absorption field on lot 100'+ On adjacent lots Public sewer main N/A Sewer/septic service line 25'+ Animal containment areas 50'+ Public sewer manhole/cleanout 100'+ 100'+ Holding tank N/A Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundafion 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line **5' Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that l have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSH guidelines in et%d on this date. Engineers nn dame JEFFREY A. GARNESS Date l�s�l3 (Rev. 11105) 97/01/2012 15:53 8686770 APLUS PAGE 09 189228 mom n ■■■ ■ ■ ■■ ■ of o ■ long man � Man ■n ■ ■ ■ ■nn■ ■ ■ nn ■■ ■■■ s� as 0 1■ ■ ■■■g ■nn■g■ g■ sus A tvanftxa Rold MaNwance Report gnchorageTank & Welding, Inc. Annual Inspection 907-272-3543 reeey deem mews a owmw Tammy 0SW31d We Blakeslee IWAA owmn eeaa 13315 Glen Alpin, Andtarmae AK 99516 (907) 348-7333 17Cmroa Caab Na - P,da mu M& am hival.Rls AX -104285 SWO40392 203620 RTU1034M 07120/x011 Rebtew OILSt Inds Daayrow ®uao retie Timer wnh w Perrum Flee sompllnwobourvatlsge lITU (15 s NTUsi pft (bs;) DO r2.di Cummc � 5 odor of SEWIN TwIm MU' [I Ew y ❑ Me* Non4ypM�t suede ❑Cebbeea 000 y awymmaimu ❑Yea ONO Fawn In task ❑Yes ❑No Check Comb+ Panel aedm'} 1 r2,, � Audift esd wWW oloms ACK DMIUmm"mmwenhti Xy. ❑Na I=Pmc Olaas Pump oyatam AharA.ld .....................0z SptwBoz .................. . Fbaes........................ Pump ........................ Blateeea F 1tw.... I .... ... ..... BNAa6aPumpvuo,- ...,..... tiae7radasn8 &+Meer valve....... Commeun INawure Sludow/seum 1st CsmpmbnaM Co'" i/ Pisviwe Cummc PmMPw and Compnhnem Casam pnroun Cu"a t Prevleus Inepesllgean AWanT1a Fluor Odor. Noretd ❑pwaNd Blame! 9Nonow - ❑amuroe erldBlnp/Penafi,p, 4NWA livor ❑Ewmuhm Inspest/Cissn Did eberae Awls alp tem Me RWWAJd spoor aft Float cards Inepes!/sonik Oltar 8lrahm Csmpsnerrls Ln%mlwDftee Pod Bottum g ottu teteka Ymtt 1 T X RNAS Pump knpsot Chan Inspect Clam abbriaolm KwApmem z Diispenal lahrffiladlle X / CbsenirHona Additional asselsee Pondered ❑CNanod WWG shwm7 ❑NepbCmd WKerna R ❑wpbd.dAtaadatkmftftTW %° V Parva used. W . tAMrrantA a = BMahle V appropriate wteoeenl. IN ■ nam Nureler basmtedea Flneusefety Ift"Noden P—rw Anaded. Mend Gcta% nuh wl"A doed Cdm mw summary/ReeommendBuono ❑Syetwn performYrat nn &Now arbor needed ❑Tar* Mario PLnPmB ❑ Cdlfor oaMca ❑ oth" Fax completed form to 1-866.384.7404 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAHILY DWELLING Parcel I.D. 021-022-50 1. GENERAL INFORMATION Expiration Date: Complete legaldescription T12N, R2W, SECTION ,30; W2, SE4, NE4, NE4, SE4, Location (site address or directions) 15515 GLEN ALPS ROAD * ANCHORAGE, AK 99516 Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address GEORGE & GLENDA STEVENS Day phone 548-7555 15515 GLEN ALPS ROAD * ANCHORAGE, AK 99516 Day phone TRACY CRAIG w/ DYNAMIC Day phone 3111 "C" STREET * ANCHORAGE, AK 99505 261-7510 Unlessotherwiserequested, HAA willbeheldbyDSD ~rpick~. 2. NUMBER OFBEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well · Individual On-site · Individual Water Storage [] Individual Holding tank [] Community Class Well [] Community On-site [] Public Water System [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Cedificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authodty Appreval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein, I further verify that based on the information obtained from the Municipality of Anchorege files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Phone Date 537-6179 Engineer's Comments: C_.~-,4~,'~'-~ ~¢~-~.... ,~o~,,.,~-,_0 t~s,-'~' ~E A In conducting this evaluation, GEG, Ltd. attempted to ~rovide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA system under the conditions encountered at the time of the test, and separation .'" fluctuate during the year, and the water usage of the family being sewed by the system. Th esecondflio.sareo~tsidethecont~ioftheevaluatorofthesystem, Satisfacto~test ~~:~, .......... results do not guarantee future peffo~ance of the system, nor do they guarantee that n ess:' there a~ no hidden defects or encroachments. GEG, Ltd. can themfore not pmvide : any wa~anty or future estimate of how long the system will continue to meet the operational ~quirements of the ADEC or MOA DSD. The content of this repo~ is for the sole benefit of the owner listed above. Any ~liance upon or use of this repoR by any other person or pa~y is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for - __ bedrooms. Disapproved. Conditional approval for 4 bedrooms, with the fllowing stipulations: Th~. u?,n~r, ~i~ int'h~¢ nf ~'h~, mnHntl~,A AiCnnCnl ~v~+¢m m,,~+ ~.,~,~;e+ ^,~ fop ¢^;I ,~,~,-I .... + k, vegetated/re-seeded by ,Tune 15, 2005. Attachments: HAA Checklist Manitenance Agreements Septic System Advisory Well Flow Advisory (Rev, 12/01) Supplemental Engineer's Roort Municipality of Anchorage Development Se ices Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: T12N, R2W, SECTION 30; w2, SE4, NE4, NE4, SE4, Parcel ID: A. WELL DATA *CASED TO BEDROCK Well type PRIVATE IfA, B, or C provide PWSID# N/A Date completed 8/7/1997 Sanitary seal (Y/N) YES Total depth 105 ft. Cased to *3 ff. FROM WELL LOG 8/7/1997 34 Date of test Static water level ft. Well production 5 g.p.m. WATER SAMPLE RESULTS: Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION 9/14/2004 36 ft. 1.61 g.p.m. 021-022-50 YES YES 12+ .in. 0 colonies/100 mi. N/A mg.IL. Coliform Arsenic: B. SEPTIC/HOLDING TANK DATA Tank Type/Material ADVANTEX/STEEL Tanksize 1500 .gal. Number of Compartments __ Nitrate 0.1 mg./L. Other bacteria 0 colonies/100 mi. -- 9/30/2004 Date of sample: 9/14/2004 Gollected by: GEG, LtD. Date installed 10/7-8/2004 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Date of pumping NEW C. ABSORPTION FIELD DATA Date installed 10/7-8/2004 Length 40 ft. Depression over tank (Y/N) NO Pumper ~'BELOW FINAL GRADEJ Soil rating ~r ft'/bdrm) 6.0 Width 5 ff. Total depth *2.74+ ft. Eft. absorption area 200+ ft2 Monitoring tube YES Date of adequacy test NEW Results (Pass/Fail) - High water alarm (Y/N) YES System type SHALLOW TRENCH Gravel below pipe 0.5 ft. Depression over field NO For 4 bedrooms Fluid depth in absorption field before test - in. Elapsed Time: - min. Final fluid depth - Any rejuvenation treatment (past 12 mo.) (WN & type) Water added - gal New depth - in. in. Absorption rate >= - g.p.d. - If yes, give date - D. LIFT STATION Date installed 10/7-8/2004 TIMER/ "Pump on" level at 29 in. Datum BOTFOM OF TANKS E. SEPAPu~TION DISTANCES Size in gallons 1500/86 TIMER/ "Pump off" level at 23.5in. Cycles tested NEW Manhole/Access (Y/N) YES High water alarm level at 46/56.75 in. Meets alarm & circuit requirements? YES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer/septic service line 25'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout Holding tank N/A N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Properly line 5'+ Water main N/A Water service line 10'+ Wells on adjacent lots 100% SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line *5'+ Water service line 10'+ Curtain drain NONE KNOWN F. COMMENTS Building foundation. 10'+ Surface water 100'+ Wells on adjacent lots 100'+ *WAIVER GRANTED Absorption field Surface water 5'+ 100'+ Water main N/A Driveway, parking/vehicle storage 10'+ G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Date lO/( ~ /~ ~ JEFFREY A. GARNESS Date of Payment Receipt Number (Rev. 12/01) Waiver Fee $ Date of Payment Receipt Number SCS Rech 1046027001 Client Name Garness Engineering Group, Ltd. Project Name/# 13315 Glen Alps Rd. Client Sample 1D 13315 Glen Alps Rd. Illatria Drinking Water oampie Ketnatks: All Dates/times are Alaska Standard Time Printed Date/time 09/24/2004 14:22 Collected Date/time 09/14/2004 9:05 Received Date/time 09/14/2004 11:00 Technical Director Sfephe . Ede Released�B����.�F e Parameter Results PQL Units Method Container ID Allowable Prep Analysis .Imus bntc Tale lnif Watara Department Nitrate -N Microbiology Total Coliform 0.100 U 0.100 mg/L EPA 300.0 c011100mL SM20 9222D D (<=10) A (<=1) 8SO-1 EO/ZO'd 61E-1 IOES19S106 S30IA83S AN3 en 09/15/04 01A 09/14/74 DKC 4 IS3 3110i108d NdSS:EO 90 -OZ -60 ■0 IB -05-u4 09:I11Al1 i� f� FRO"T&E ESI, SGS ENV SERVICES SGS/CT&E —SR$— 9075615301 V Drinking Water Analysis Report for Total Coliform Bacteria READ INSTRUCTIONS ON REVERSE EIDE BEFORE COLLECTING SAMPLE MUST BE COMPLETED BY WATER SUPPLIER [� PUBLIC WATER SYSTEM IDtt PRIVATE WATER SYSTEM 1A Sent Results W send IIWA. (� Send Results SAMPLE COLLECTION: Dna: Faren >u.rr7—Ym.w awr, Tena: % y'S fhsl AAA PI Collector.rL�L��il� Nw. w,r Tmnsponed to Lab By: M Same as collector Other. TO BE COMPLETED BY LABORA Samnle Receiving: Delivery Method: Received By: Comments: SAMPLE TYPE SamPle over 30 bouts old; Result, may be untallable ❑ 40 Has For T-436 P.01/01 F-251 200 W. POTTER DRIVE ANCHORAGE, ALASKA 99510 Tel. 907-562-2343 Fax: 907-581-5301 Lab Rel No. 1046455• i/Q 0 Setai ktvoke r+•.a u.m. fY M,/Ilpr GRIN - f Outlne ❑ Treated Water ❑ Repeat sample Auntreated Water (refer to lab no. j _ ❑ Special Purpose ❑ RUSH SAMPLE Phone t:: Sfax p: .........................•........................+....................................................................... ................ i SAMPLE COLLECTION: Dna: Faren >u.rr7—Ym.w awr, Tena: % y'S fhsl AAA PI Collector.rL�L��il� Nw. w,r Tmnsponed to Lab By: M Same as collector Other. TO BE COMPLETED BY LABORA Samnle Receiving: Delivery Method: Received By: Comments: SAMPLE TYPE SamPle over 30 bouts old; Result, may be untallable ❑ 40 Has For T-436 P.01/01 F-251 200 W. POTTER DRIVE ANCHORAGE, ALASKA 99510 Tel. 907-562-2343 Fax: 907-581-5301 Lab Rel No. 1046455• i/Q 0 Setai ktvoke r+•.a u.m. fY M,/Ilpr GRIN - f Outlne ❑ Treated Water ❑ Repeat sample Auntreated Water (refer to lab no. j _ ❑ Special Purpose ❑ RUSH SAMPLE Phone t:: Sfax p: .........................•........................+....................................................................... ................ Bacteriological Water Analysis Record- SetetoADEC: MM04AUG IP/AI RESULTS: ANC FBK JUN 10ateiTwne- Analysis Basan• P Taal Cddon is Analyst: E. Cdi: Sent to Client Analytical Method: MEMBRANE FILTER RESULTS: Phoned Q - Fazed DZI Dlmct Count Pf Colmms/t001nL D.wr ne /(1 I i /7 j ® Membrane Filter vaon: _( r— SPD" With 7 ❑ MMO-MUG (P/A) �,,,�„• LTB: —COGS 52 Satisfactory rsrew.. ( Ec: ❑ .Unsatisfactory TNTC-T»rrar ReportedBy: � DatelTlme: lo/' / / ?30 on -00,134.n. Sgwx.e (j Fort 9 FW- 0053 12/17/03 ~,~CT-~0ot,I¢, 200¢:F I:10PM~ :Garness En~fneerin~ Grou~, Ltd, TO=;~;~9;~.4,S N0,1291 P, 2t TAX ~9 89°59'20'£ 164.21' WALLS ~--roUHD 5/8" ;[~ ('rYPzCAL) DRIVE' ' LOT 2 ~ ALPS ESTATES · RETAININO P-RAVEL PARKING / / / / / ~.r'~' ~'A[NINO WAU TAX ¢2~ PLANT CLF. ANOUTS THREE STORY ~YOOD FRAME RESIOE,qC£ I~~/ / / LOT I OllrN AU:~ ESTA]~$ ADDH ~t CLEANOUTS TAX f2~ Oct.14. 2004 I:IOPM Garness EnsineerJns Group, Ltd. No.1291 P. 3 £2] PL~T PLAK -- AS BUILT X SCALE 1"=40° OR~ 2943 Proje=t Ha. 04-208 Lang-&ASsoclates.---=- inc. ,1 o0 oo , ,-.u., , horo0o. ,,o.ka (~07) $22-$476 Phone Registered Land Surveyor~ (907) $2:Z-~G25 Fax www,langsurveyors.¢om / lnfoOlang~urveyora.com I hereby Certify that I have a~r,/e,/ed the follo~ng de*el-lbed properly: W~/2, $[f/4, NE1/4 H£1/4~ S£~/4, SEC ~0, TI2N R2W, ~I M Anchorage R'eeordlng Olefrfcf, Alaska, e.qd that '}he mprovamants zltuafed thereon are wlthln the properly line, and de r~t encrmaoh onto the properly adjacent fheretco ~ ne Improvements ol~ the praperly lying adJaceni therelc encroach on "/ne surveyed prernleee an~ that there ere n~ roadwayl, franaml~elan lines or othir vf~b]e eammmenf~ ors said properly except as Jl~dleated hm~on. Dated this the ~.~'H~ Day cf ,¢L~¢. ,9--~,O_<L=, ct Anchorage, Alaska Il Is fha raspen,lblllly of the ewner to determine the existence of any ec~ement~, aavenanf~, ce rorlrfefla~e which de n~t appear an Ihs rocerdsd subdivision plat, i ITAX !9 N 89.59'200E 164.21' FENCE ENCROACHES 1.0' /-RETAINING LS rra' GRAVEL DRIVE 4�� , •.� LOT 2 RAVEL- -PARKING` -GLEN ALPS ESTATES (MICROWAVE TOWER SITE) •. 1.8�,VtCK OVERH kNG3, .o MANHOLES RLTAINING WALL " '•'• od TREATMENT PLANT SEPTIC CLEANOUTS M ,Nt 1° �• 1.7' X 1(.6' CANT / v SECOND i rL ��� 73.9' 0 1.8' X 3.9' CANT I c 1.1' X 2.0' CAN nDeo rtoort 1 = WIUNNO UNE I THREE STORY ODD TAX /21 pROTfCTy FRAME RESIDE CE 1 ELL f l0pllRADlt/ I 8 S 89'S9'20aPI64.16' / LOT 1 GLEN ALPS ESTATES ADDN /1 PLOT PLAN AS BUILT X SCALE 1'=40' GRID 2943 Project No. 04-208 i TAX /8 FOUND 5/8' REBAR (TYPICAL) TAX ;22 TAX /23 Lang & Associates, inc. 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Registered Land Surve ors (907) 522-6476 Phone Y (907) 522-4623 Fax www.longsurveyors.com / InfoOlangsurveyoro.com I hereby certify that I have surveyed the following described property: Wt/2, SEI/4, NEI/4, NEI/4, SEI/4, SEC 30, T12N, R2W, S.M. Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no Improvements on the property lying adjacent thereto encroach on the surveyed promises and that there are no roadways, transmission lines or other visible easements on said property except as Indicated hereon. Dated this the Day of at Anchorage, Alaska It Is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. —