HomeMy WebLinkAboutHILLSIDE NORTH ADDN #9 LT 6Hillside North #9 Lot 6 #041-032-09 Municipality of Anchorage Page t of 3 Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw, Street P.O. Box 196650 Anchorage, AK 99519-W5o www.cl.anchorage.ak.us (907) 3437904 OWSITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWM041 PID Number. 041-032.09 R.n•: Gr o Motyka Wastewater System: New Adwwa P.O. Box 90846 Anch., AK 99509 ABSORPTION FIELD • wrow a e•meae.: 333.9977 Four 4 Deep Trench LEGAL DESCRIPTION se+Rw V law D.pm Yom aq•W Q•d•: ,6 GPD/Fe 12 Ft. tt a La si,,!) n Dean b p9• Yolbn Yao&Vp ar•d• Cx•w degn ewwel p" 6 Hillside North Addn. 9 4 Fl. 8 FL T-Y*W Rw" sworn: Frraddwd•oo 0rVnrvd• Cxe Lwpdi 1-2.5 Ft. 67 Fl. Well: New Gr..w wM 3.5 IYn10•r a r,... 1 awn. Dwwwl Ynn. Fr. FL cmuftew, (Prrvw•, A, B, Cl: 7" D•qn: C•••d b To abw pt a ww " imtww. Private 84 184 1,072 Fe ASTM 3034 PVC PJI•r Dw• Dn Stwn Www L• , Alpine 5123104 54 FL AMAQ Corporation 6117.20104 Y,•M. 8 P" swa'. 1 Cary Ao Grana >2 TANK GPM Fl. Ft SEPARATION DISTANCES 0 Septic ❑ Holding 0 S.T.E.P. I] Other. To Septic Absorption Lift Holding From Tank Field Station Tank sewerune Anchorage Tank 1,250 wr >100' >100' WA NIA >25'Steel Two (2) srn.o•ww >100' >100' WA WA LIFT STATION — NONE ON LOT La Lir >5' >10, WA WAC w Fandarian >5' >10' WA WA "`"�' �'° w in ti WL a.,wna.n None Noted PuryM•k•6ModN EWar 1,-PepraePwk..dpr Ren,rYc BENCH MARK Back Deck Southeast Comer. A•wmwl Ewwm: tgtl.0 FL Engineer's Stamp `r x```99 ��♦ 0:49th � `�" Inspections performed by: MEA Dates: 1'L 8/12104 0 A 2 nd8/12104 : fi,MICHAEL E. ANDERSON 4yy, Department of Health and Human Services approval •• s No. CE -4381 f �% Date:cZ'/6-0� ♦♦♦•h�fEssa::`�• mRevi�wedandapprovedby: Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT Page 2 of 3 4700 South Bragaw Street Anchorage, AK 99519-0655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SWO40041 I'll', ; PID No. 041-032-09 N 1� 1 1 y� TNI S2 sl I �1 S 4 BeAfOGRI I 2 "Offb 1 Fp i I f N1 i ' 1 c3 HILLSIDE NORTH SUED., ADDN. NO. 9 LOT 6 ".&" ai. %0 HAVEN OROX {c ;+ >a w .IM1�E *% NoPLAN AS -BUILT ♦. 0:-4381 fff�`i •. .•••FF .MNp•�••• SCALE 1" = 60' le I 1 Afa SS$I 3C127Mt 3j CS 43 N 1� 1 1 y� TNI S2 sl I �1 S 4 BeAfOGRI I 2 "Offb 1 Fp i I f N1 i ' 1 c3 HILLSIDE NORTH SUED., ADDN. NO. 9 LOT 6 ".&" ai. %0 HAVEN OROX {c ;+ >a w .IM1�E *% NoPLAN AS -BUILT ♦. 0:-4381 fff�`i •. .•••FF .MNp•�••• SCALE 1" = 60' Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SWO40041 N CUM y N UU Bend P U PID No. 041-032-09 U f f N U PROFILE AS -BUILT scale: V • 1P Mayor Municipality of Anchorage Department of Health and Human Services 84'L' Street P.O. Box 190650 Anchorage, Alaska 99519-6650 hnp:#*ww.ci.anchonga ak.ua Permit Number. #SW 040041 Date of Issue: 4-1.04 Parcel Identification Number -041-03 Date Started: 5-23-04 Date Completed: 5-23-04 Is well located at approved permit location? ® Ya El No halal Description: Hillside North Add/tb7 # 9 Subdhrision Lot 6 Property Owner Name & Address: Gregory Motyka PO Box 90846 Anchornae. Alaska 99509.0846 Borehole Data: Soil Type, Mietm m & Water Strata Depth (ft) From To Method of Drilling 1Z air rotary ❑ cable tool Casing type: , tpj Stick up 0 .. .2 _ Wall Thickness: 10 inches . gravelly sbt 2 59 Diameter. ¢ inches' Depth:11 feet silly sandy gravel wet 59 62 Liner Type: gravelly sdt S* sandy gravelly silt grsvelly sandy silt H2O 62 67 67 '76' 67 73 76 84 Diameter: inches Depth: feet Casing stickup above ground: Z feet Static water level (froth ground level): '�4 feet Pumping level:ifeet after Z hours pumping I gpn Recovery Rate: $ gpm Method of Testing: $klid Well Intake Opening Type: ® Open End ❑ Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: hentonite it 8 Volume: Lhg Depth: Start 9 feet Stopped 9 fat Pump: Intake Depth feet - Pump size hp Brand Name Well Disinfected Upon Completion? ® Yes Q No Method of Dhinfection: chlorine tablets Comments: Well Driller. Alpine Drilling 6 Enterprises PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property MUNICIPALITY OF ANCHORAGE Development Services Department Onsite Water 6 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SW040041 Date Issued: Apr 01, 2004 Expiration Date: Apr 01, 2005 Parcel ID: 041-032-09 Legal Description: ;HILLSIDE NORTH ADDN #9 sUBDIVISION LOT 6 Design Engineer: 0014 Anderson Engineering Site Address: NHN HAVEN CIRCLE Owner Name: GREGORY MOTYKA Lot Size: 99655 SQ. FT. Owner Address: PO BOX 90846 Total Bedrooms: 5 Permit Bedrooms: 5 ANCHORAGE. AK 99509-0846 This permit Is for the construction of: ❑✓ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received Issued Date: 0 4 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 041—OR-07 Permit Number SW 0 5004/ Property owner(s) Gregory Motyka Day phone 333.9977 Mailing address (1) P.O. Box 90846 Anchorage, AK 99509 SITE Mailing address (2)MHN 14J9VEN C/RCLF Zip Code `/9507 Legal description (Lot, Block & Sub'd.) Lot 6. Hillside North Subdivision, Addition No. 9 Legal description (Section, Township & Range) Lot Size 996 SS Acres q.Ft. Number of Bedrooms Five (5) THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well ® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: !P3215 — Waiver Fees: Date of Payment: Date of Payment: Receipt Number: `i N ZO Receipt Number: (Rev. 12100) C} iQ/p 51V2/42 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX March 29, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 6, Hillside North Subdivision Addition No. 9 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 6, Hillside North Subdivision Addition No. 9 intends to construct a five - bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to serve the new home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well, septic system and alternate site. There is currently no development on lots adjacent to this lot and no conflicts exist between the well and septic system proposed for this lot and those on adjacent properties. Contour lines with representative surface slopes are shown on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Test holes placed on the lot in the area of the new absorption trench indicated silty sand with gravel and some cobbles to 12" in diameter. The accepting soils were tested and found to have percolation rates ranging from 16 to 18 minutes per inch. No groundwater was found during excavation and none was noted during the monitoring period. We are therefore proposing to place a new 1,500 -gallon septic tank along with a 80' long by 3' wide by 8' effective depth absorption trench to collect and treat the sewage generated in the house. The bottom of the trench will be 11' below the surface. A minimum of 3' of cover will be placed atop the trench and 4' atop the new septic tank. The ground surface on the lot slopes at grades up to 15% from east to west as shown on the Site Plan. The absorption trench will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from the well proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface Lot 6, Hillside North Subdivision Addn. No. 9 March 29, 2004 Page Two water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, 0-t-, Michael E. Anderson, P.E. Attachments '4749 th )FK MICHAEL E. ANDERSON E No. CE -4381 ,0 r � wra ua.w�eu r� co..eR lew artd �� �LlOOD uoaslV j 'o Got m Y a u O L cr u I' Q' w a' m i tm L Q1 vbm LOT 6, HILLSIDE NORTH SUBDIVISION, ADDITION NO. 9 DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom House 5' Wide Trench System Perc. Rate: 16 Min./Inch 1,500 Gallon Septic Tank Application Rate: .6 GPD/SF 8' Drainfield Rock 5 Bedrooms X 150 GPD/.6 GPD/SF (Application Rate) = 1,250 SF Absorption Area 1,250 SF/16 SF/ LF = 78.1 LF Trench Length THEREFORE: Construct a 80' Long x 3' Wide x 8' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 11' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Natural Backfill 2'6" Geotextile Fabric 6" t 4" Perforated t PVC (Holes Down) 810" 1 I— Drainfield Rock F 3 4 TYPICAL DEEP TRENCH SECTION •••.,�, (NO SCALE) E •� NOTE: Grade Area Over Trench to Drain Away. 49m Minimum 6' Separation From Bedrock. �._.; ..... Minimum 4'Separation om Minimum 100' Separations FromrSurf ce Minimum 100' SepaWater or Streams. �. �k.,. Na CE4ml LE. ration From Wells in the Area. YiC IiNOER VeTec•h Engineering Technical `. P.O. Box 873141 Wasillo, Alaska 99687-3141 Phone: 907-357-6304 Fax: 907-357-6305 I SOILS LOG - PERCOLATION TEST I LEGAL DESCRIPTION- LOT 6, HILLSIDE NORTH ADD#9 S/D i •, DATE: R 3/100 04 AMAO EXCAPROJECT No M0410 VATINGfell j�0. PR``O`FE`SS% PARCEL ID,11. TECHNICIAN: T.L.KIMBROUGH Prolee`Q 01L DEPnI TEST HOLE # 1 Type of Test: E Percolation ❑ Visual (f"t) 1 OB/OG 2 3 4 6 BROWNISH -GRAY SILTY -SANDS W/GRAVELS SOME COBBLES TO 12" 8 MEDIUM COMPACTION MED MOIST 9 10 15 16 17 18 19 ::F SITE PLAN THIO � It TH2o SEE FUTURE ASBUILT CIOo/ 0% C50% DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) WATERF (INCHES) I NET DROP (INCHES) 3/10/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 10:25 8.0' CHARGE 2 10:55 30 6.0" 2' 3 10:55 8.5" RECHARGE 4 11:25 30 6.625" 1.875' 5 11:25 8.0" RECHARGE 6 11:55 1 30 6.125' 1 1.875' PERCOLATION RATE•• 16 (MIN/INCH) FERC. HOLE DIA. 6 fINCI1ES) TEST RUN BETWEEN. FT. and 5_5 FT. WAS GROUND WATER ENCOUNTERED? NO IF YES Q WHAT DEM19 DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING: $ �� COMMENTS: NO IMPERMEABLES ENCOUNTERED TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE- VeTeah Engineering P.O. Box 873141 Wasillc Phone: 907-357-6304 DEPn I (rat) 2 n Technical S Alaska 99687-3141 Fax: 907-357-6305 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION- LOT 6. HILLSIDE NORTH ADD#9_S/D PERFORMED FOR- AMAO EXCAVATING DATE: 3/10/04 PROJECT No • M0410 PARCEL ID/j• TECHNICIAN: T.L.KIMBROUGH OB/OG TEST HOLE #2 6 BROWNISH -GRAY SILTY -SANDS W/GRAVELS SOME COBBLES TO 12' 8 MEDIUM COMPACTION MED MOIST 9 11 me 17 E Type of Test: ® Percolation ❑ Visual SITE PLAN THIO- 1-0 n a TH2o '5 11 SEE FUTURE ASBUILT o . not 0% = 1 7!nd DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DW TERF (INCHES) NET DROP I (INCHES) 3/10/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 10:35 10.0" CHARGE 2 11:05 30 8.125' 1.875' 3 11:05 10.0" RECHARGE 4 11:35 30 8.25" 1.75' 5 11:35 10.0" RECHARGE 6 1 12:05 1 30 1 8.25' 1 1.75" PERCOLATION RATE• 17.1 (MIN/INCH) FERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN:: 4_5 FT. and 5_5 FT. WAS GROUND WATER ENCOUNTERED? NO IF YES @ WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING: 3 Z COMMENTS: NO IMPERMEABLES ENCOUNTERED TEST PERFORMED BY VETECII ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 6, HILLSIDE NORTH SUBDIVISION, ADDN. NO. 9 GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,500 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 80' long X 3' wide X 8' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 3' below the existing ground surface. Total depth of the trench will be 11' below the existing ground surface. The new absorption trench must be placed a minimum of 100' from the well on this and adjacent lots. A minimum of 10' must separate the trench from the lot line. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,500 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Lot 6, Hillside North Subdivision No. 9 March 29, 2004 Page 2 of 3 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cieanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. Lot 6, Hillside North Subdivision No. 9 March 29, 2004 Page 3 of 3 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. jar -W Municipality of Anchorage Development Services Department Building Safety Division Onsite Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.d.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FORA SINGLE FAMILY DWELLING Parcel I.D. 041032.09 1. GENERAL INFORMATION HAA# D5 o�z Expiration Date: 0 Complete legal description Lot 6 Hillside North Subdivision, Addition No. 9 Location (site address or directions) 9660 Haven Circle Anchorage AK 99516 Current Property owner(s) Gregory Motvka Day phone 333-9977 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address P.O. Box 90846 Anchorage AK 99509 — Unless otherwise requested, HAA wDl be held by DSD for pickup. 2. NUMBER OF BEDROOMS 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System Four 4 Day phone Day phone TYPE OF WASTEWATER DISPOSAL: ® Individual On-site 19 ❑ Individual Holding tank ❑ ❑ Community On-site ❑ ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system Is(are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522.7773 Address _P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 2/9/2005 S. DSD SIGNATURE ✓ Approved for ---q— bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: HAA Checklist X Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other By: (Lc.1�. / �o �// Original Certificate Date: d Municipality of Anchorage e • Development Services Department Building Safety Division " Onsite Water 6 Wastewater Program s " 4700 South Bragaw SL P.O. Box 196850 Anchorage, AK 99519-6650 www.cl.anchorege.ak.us (907) 3437904 HEALTH AUTHORITY APPROVAL CHECKLIST � _ . � . .1 .Il . •u•� � :dui- • � • � - _ � � g �r A. WELL DATA Well type Privets If A, B, or C provide PWSID s _ Date completed Sanitary seal (YIN)! Total depth _R -R. Cased to A4 ft FROM WELL LOG Data of lest S23RQ4� — Static water level S4 ft. Well production 8 9 -P.M. WATER SAMPLE RESULTS Weil Log (YIN) Wires property protected (YAV) Y Casing height (above ground) 24 in. AT INSPECTION ft 9.p.m. Coliform J_coloniesl100 mi. Nitrate 1.68 mg.A. Other bacteria __L ookmies1100 ml. B. SEPTICIHOLDING TANK DATA Tank Type/Material See00020 Tank sits 1250 gal. Number of Compartments j Foundation cleanout (YIN) Y Depression over tank (YIN) y Cleanouts (YIN) Y High water alarm (YAV) N Date of pumping Pumper New Constnrction C. ABSORPTION FIELD DATA Date installed 618R004 Sob rating (9-p.d.fie or fe/bdrm) .6 GPDMF System type Dee° Trench Length 67 R Width 3.3 fL Gravel below pipe 8 ft. Total depth 13-15 fL Eft. absorption area 1.072 fe Monitoring tube Y Depression over field N Date of adequacy test Results (Pass/Fail) For _ bedrooms Fluid depth in absorption ftek1 before test _ In. Water added_ gat. New depth_ in. Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >= 9 p -d. Any rejuvenation treatment (past 12 mo.) (YIN fL type) N If yes, give date D. UFT STATION Date installed Sae in gallons 'Pump on' level at _ in. 'Pump ofP level at _ in. Datum E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tanknift station on lot >1W Absorption field on lot >JW Public sewer main WA Manhole/Access (Y/N) High water alarm level at in. Meets alarm & circuit requirements? On adjacent W _MW On adjacent lots >1W Public sewer manhakdcleanout WA Sewer /septic service fine >25' Holding tank WA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >S Properly line >_,Er Absorption field >S Water main WA Water service line MO* Surface water >IV Wells on adjacent kits MW SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10, Building foundation _ >10, Water main >10' Water Service line >10' Surface water >1W Driveway, parking/vehicle storage 5,25' Curtain drain None Noted Wells on adjacent lots MW F. COMMENTS G. ENGINEERS I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in _ t conformance With MOA HAA guidelines in effect on this date. L rObMEL E MaQSW Engineer's Printed Name Michael E. Anderson. P.E. `, No, CE -,3m ;'% Date 2191 =5 v.�j �ee1.• /iN..... HAA Fee $ �7 V/ 7S �vs N Waiver Fee $ _ Date of Payment 2 �� psO S Date of Payment Receipt Number f'9 3� ocP t,, � Receipt Number, lrtev. 12M) I ■■■ 2-14-05: 6:05PM: SGS Ref. #: Client Name: Project Name: Client Sample ID: Matrix: PWSID Sample Remarks: 1050674 Anderson Engineering Hillside North, #9, Lot 6 Hillside North, #9, Lot 6 Drinking Water :907 56,5301 CT&E Environmental Services 200 W. Potter Drive Anchorage, AK 99518 Tel: (907) 562-2343 Fax: (907) 561-5301 All datesttimes are Alaska Standard Time Printed Date/Time: 02/14/05 16:50 Collected Date/Time: 02/09/05 10:25 Received Date/Time: 02/09/05 10:52 Technical Director Stephen Ed 1.00 mg/kg EPA 300.0 10.00 02/10/05 Released Byr—•/" mx Allowable Prep Analysis Parameter Results PQL Units Method Limits Date Date Init Bacteria 20B, w/o coli 9222B 02/09/05 02/11/05 do Nitrate 1.68 1.00 mg/kg EPA 300.0 10.00 02/10/05 02/10/05 mx • 1/ 1 2001-176 HILLSIDE NORTH SUED., ADDN. NO. 9 LOT 6 99.656 S.F. HAVEN CIRCLE s�or mown [sur. • G 6rf.