Loading...
HomeMy WebLinkAboutDON JACK LT 2Don Jack Lot 2 #020-092-60 Municipality of Anchorage Page 1 of 3 Development Services Department On-site Water and wastewater Program 4700 South Bragaw Stmt P.O. Box 196650 Anchorage. AK 99519-6650 www.d.anchorage.ek.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO30508 PID Number. 020-09260 wna. Dane Bandell Wastewater System: New A00aee: 13771 Venus WayAnchorage, AK 99515 ABSORPTION FIELD Prolw rAn6ar of senoune 345 4016 Feurfdl 5' Wide Trench LEGAL DESCRIPTION 'a`� ° T""� "°" ° a " ewe Lw 1.2 cROTP 3 n swaiw.olL BENCH MARK Garage Slab Inspections performed by: AH Dates: 1a 6/8/04 2ne 619104 Department of Vealth and Human Services appr�o�v"alb Reviewed and approved by. ate: ��4M:M , (Ree, l e _� _-.T_ 100.0 FL Engineer's Stamp 49th MICHAEL E. ANDERSON , No. CE -4191 Don Jack 1 Ft. 2T Tom' R.ge: 6ac0on: Fi aoaeG sows onplwl V•ae FE &awl LenprL 2.5 "• 70 FI. Well: New .M wq 5. Nutter ul Yye. aMiM E. Yae YM. CWvfral,iarn (Pllvala, A 9. Cl: Private TrAY D.pin Caws b Ft. al.l eborpllen r 1 Fl p wW. 346 FI. 50 FE 500 FF ASTM 3034 PVC AI Ine Drillin Doe 0w 6/6/04 StM wwM�rLw 52 FL Cat's Eye Excavating 6/8.912004 r.a. RI.m s.l a car•n Apps G 5 CR"' FI• wnl >2FI TANK SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Sep IC Fran Tank Absorption Field Lin Station Holding iWrNne Tank Seune Sow Anchorage Tank 1250 well>100' >100' NIA WA >25' Steel Two 121 S.racewr.r >100' >100' WA WA LIFT STATION — NONE ON LOT La UI1. >5 >10' WA WA c« Faulasvl >5' >10' WA WA ti in h cWll ti.I1 None I Noted "'"° ° EMrnul Vpvc, *pwft Wpr. Remrke: BENCH MARK Garage Slab Inspections performed by: AH Dates: 1a 6/8/04 2ne 619104 Department of Vealth and Human Services appr�o�v"alb Reviewed and approved by. ate: ��4M:M , (Ree, l e _� _-.T_ 100.0 FL Engineer's Stamp 49th MICHAEL E. ANDERSON , No. CE -4191 00.591 M.,99JO OON } �' ��• tuawase3 le3ul3 3M0. CD uo t a; i O m im C14 a d 50,00 €E Z a wms � Q!e<omo m m cqciO N O ANO n0 O C a 1�m�NN UN) (3 c W W o cl W co CD rW O) O f0 r M CC Ln rn C) ti CD Lo J 0a bf o m _ ��//� � < L) rn d CO p > ® U Q W C N = w f0 u) a O Z Z a=um Q Ewg'O �o wrn 3 ®r= > C m pmt r 0 W U) — — — o c �uawase3 3 S 1,O1 oco ^ p 0 o pails A}Ia8 U a� E _0 > o ..='L N a s CL O m �� _ N Y Q 2 O O cl F O J Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 995196655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SW030508 TBM PID No. 020-092.60 V = U PROFILE AS -BUILT Scale: 1' - 20' r PINE DRILLING Rick Mystrom Mayor FAX N0. : 907 345 0102 Dec. 06 2004 11:09RM P1 Municipality of Anchorage Department of Health and Human Services 825'L' Street P.O. Box 196650 Anchorage, Alaska 99519650 htt0•lMn w.ei.anchorsge.akus Permit Number: #SW 030508 Date of Issue: 12-29 03 Date Started: 4 4 Date Completed: 0-6-Q4 Legal Description: Don Jack Lot 2 Property Owner Name & Address: Dane Bandell 13711 Venus Way Parcel Identification Number: 020-092-60 Is well located at approved permit location? ® Yes ❑ No Borehole Data: Depth (ft) Method of Drilling ® air rotary ❑ cable tool Soil Type, Thickness & Water Strata From To Casing type: steel Stick up 0 2 Wall Thickness:,W inches gravellyslit 2 43 Diameter: _6 inches Depth: 5.0 feet Bedrock 43 346 Liner TYpt: Diameter. inches Depth; feet Casing stickup above ground: 2 feet Static water level (from ground level): §Zfeet Pumping level.-944feet after 2 hours pumping .6 Spm Recovery Rate:,5 gpm Method of Testing:r8 } IiR Well Intake Opening Type: ❑ Open End ❑ Open Hole ® Screened Start 5-3 feet Stopped 5,Q feet ❑ perforations Start feet Stopped feet Grout Type: bentonite # 8 , Volume: I Depth: Start p fcct Stoppcd 10+foot Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: Oha&2 tablets Comments: Well Driller Alpine Drilling a Enterprises PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property .-... .ni. �.. \l J.�1\ ..L .lf .....:J. ....1f \.. �. tel. n..• .!\t..\.l • A. n. �.1... �.". !. II\ J L. \ �. K w 0 n VI O NO'o7.56 r•W /G !. pp 1 a1 n y a z M' N S O IN � 1 1 1 I I . 1 1 1 1 � 1 VEN)-3 Al ♦ I' \ \ 4 \ \ f \ \ Ip4 ZI1'weV �!r � \ SSs r. x Hay �w,yc ' \ sc • �. !4r�•114' II • 1 1 ^ M l 1 rI e i ' ' 1 1 1 1 1 li A F NO'o7.56 r•W /G !. pp 1 a1 n y a z M' N S O IN t R ��777»x 'o v g� 'fi Bo -a, S 1gg r ti s�� p3 lb J - ty gigwfss�.•� .g.� � yrz�ul w E 3W< Ar .Y/ Ax tN kl tn PY/ O IA ii/ Q I� i 1 P \ i 11 a s � �♦r ,0114 ` ^ y �s. a S NN i/i i ^ s o„ a{ ` / `-- F iff as a7i M„ ,AO O)/ m 17iYJG A•J,G_,B MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water& Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: Dec 29, 2003 Expiration Date: Dec 28, 2004 Permit Number: SW030508 Parcel ID: 020-092-60 Legal DescriptionZODon Jack Lot 2 v Design Engineer: 0014 Anderson Engineering Site Address: 16435 Betty Street Owner Name: Dane Bandell Lot Size: 49524 SO. FT. Owner Address: 13771 Venus Way Total Bedrooms: 4 Permit Bedrooms: 4 Anchorage , AK 99515 - This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. Monitor test hole in spring to determine seasonal high water level Received By: Issued By: Date: lZ—�O—U3 Date: 1 2—,2, -1' Q 3 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 020.092.60 Permit Number SW O 30 S0$ Property owner(s) Dane Bandeli Day phone 345.4016 Mailing address (1)13771 Venus Way Anchorage, AK 99515 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 2, Don Jack Subdivision Legal description (Section, Township & Range) 1 o!A 3S R6 ' -tA sA Lot Size 49,521 —Acrese) Number of Bedrooms Four (4) THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well ® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is In accordance with applicable Municipal Codes. E (Signature of property owner or authorized agent) Permit Fees: 5 6 Waiver Fees: Date of Payment: !2 -ZZ -03 Date of Payment: Receipt Number: &k'q O Receipt Number: (Rev. 17100) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX MEMORANDUM DATE: May 28, 204 TO: Joe Goodall FROM: Mike Anderson, P.E. SUBJECT: Lot 2, Don Jack Subdivision SW030608 Revised Well Location The well location has been moved at the owner's request to eliminate a visual conflict with the new house. The revised Site Plan and Area Plan are attached for your review. The new well location does not conflict with septic systems in the area. Please let me know if you have additional questions. OMe 11 A%s�rwry N895W3M O' Etl+q N.. AREA PLAN SCALE V- 100' TRACT A moN E. NDOt50N �L No. cf+ r- . . . 0 1 . N O z C- 0 c °a. o < CL CD CC z CD Betty Street 10'T&EEasement CD -40 z co CD to C,) (YI CD co C;) C5 Z C) to Cam 0 no —10' lectndcal Easement 0 00 0 0 7,56"w 165.00 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX December 22, 2003 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 2, Don Jack Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 2, Don Jack Subdivision intends to construct a four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to serve the new home. The attached Site Plan and backup documentation identify the location and configuration of the well and proposed septic system and alternate site. The locations of wells on the adjacent lots are also shown. No conflicts exist between the well and septic system on this lot and on adjacent properties. Contour lines are shown indicating the current drainage patterns. These patterns will be maintained after construction. A test hole placed on the lot in the area of the new absorption trench completed by Brian Harten, P.E. indicated gravel with sile with a percolation rates of less than 5 minutes per inch. Groundwater was found in the monitor tube at 12' during excavation and rose to 7.5' monitoring period in mid March. We are therefore proposing to place a new 1,250 -gallon septic tank along with a 70' long by 5' wide by 2' effective depth absorption trench to collect and treat the sewage generated in the house. The bottom of the trench will be 3' below the surface and 4.5' above the groundwater table. A minimum of 3' of cover will be placed atop the trench and 4' atop the new septic tank. The ground surface on the lot slopes at shallow grades from east to west toward Betty Street. The absorption trench will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from the well on the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. Lot 2, Don Jack Subdivision December 22, 2003 Page Two If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments Mr��; tiu MICHAEL E. ANDERSON :y No. CE -4381 _j USTO 3W.13 VA N pave s { 07 V �T 1bry PnpoMEVM 1{i iW lE w W 6 � 1895971'E 0.1E A TRACT A m Ebrq WM 3 PG O Y AREA PLAN _, h-, E3} SCALE V - 100' �. t41MC1uE%E.CE�b r C O O Z C- 0 —0 co CL Fn < Q. 0 CD Z (D Betty Street 10* T & E Easement .44 Wz x q Si -x > z z co z CO (A C) CD Q C:) C." (Q to 0) C) rA 0 CD OL 0 CLO 3 , C: CD go 00 M 0 * "Oil I X 10' Electrical Easement NOO 07'56"W 165.00 *44, LOT 2, DON JACK SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House 5' Wide Trench System Perc. Rate: <5 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 2' Drainfield Rock 4 Bedrooms X 150 GPD/1.2 GPD/SF (A lication Rate) = 500 SF Absorption Area 500 SF/5 LF (Width)' .7(Red. Factor) = 70 LF Trench Length THEREFORE: Construct a 70' Long x 5' Wide x 2' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 1' Below Original Ground Surface. Total Depth to be 3' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. 6" 6" 2'0" Natural Backfill 5' Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SEC I IOf' (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Well. Minimum 100' Separation From Surface Water or Streams. Municipality of Anchorage 4:PV"6:�a's�gA�j.# • •• %SlDevelopment ••• Services Department Safety wsion . 'f • ..' Building p 49�y *`� y� On -Site Water and Wastewater Program 47DO South Bragaw SL •� ti i •�••••••• ..... .j P.O. Box 196650 Anchorage• AK 9951966650 r 96 1.. ... ............. • 1AN T. HARTEN �w w.vw d anchoraoe.ak.usBR n �0 9•'.� (907) 343-7904 CE -10068 •: ��`"� �A�i9�oP•••••••aa����' Soils Log- Percolation Test tau Performed For: - Legal Description:L.or 7 Z�.a T..�u_S 3'ur Township, J(Feet) 1. L -OA M2"Gchv� : CAWD 3- Q ';-A)5\c-Ty GZA,<z I Imo— w1 Copv3.L&s RMLf S r4+w,Ta, W TER NelTime Depth to Water Net Drop E\,Cwr n0? — IF YES. AT WHAT DEPTH? 19 p GH Te VfT" Swr— Dep4h to Water After 1 P Ftonitoring? '•S E a w� G2 td£t Ur. 3Id e 3 ��SMq.,,�•-P @. t -L 1 13• Reading Dale Gross Time NelTime Depth to Water Net Drop 14- CK, -Re -t4 - S%as tr 15- w(G+zAVC-1- loll 3�} 03 NIS 8 M\a Ou la 16- ?�. o, El. tau A to t...a p 1, 6 n 17- 11 I 0 It 4:4•S M..1 O Ir 10 1 r• 10 tl I I Is :ISN•N I 0 \. 10 Ir 19- 20- P_RCDtATIVIRue _l� 4+ lrcN PERCHUS DIAMETER TESTRUNE_r NEEN :t,_Fi ANo 3•c FT `—! COMMENTSUhTL� Sraa Gr bOoe..�F.-• OrJC M11 r4+`-rC2 TESTi4-ot.E C_r.i�s sr. LIUNI, C04,j L�r_•n..�.a TF�T/•FLtC t 712,A A THIS TEST WAS PERFORMEDBY: ��ta_1 1-. r:.2_Ti�•�._ r'�C£RTIFYTY.AT GEINEFFCT ON THIS DATE. DATE: o }EL?E P=-RFOR?•IED IN ACCORDANCE VATH P.LL STATc A• 1 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 2, DON JACK SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 70' long X 5' wide X 2' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at V below the existing ground surface. Total depth of the trench will be 3' below the existing ground surface. The new septic tank and absorption trench must be placed a minimum of 100' from the well on this and adjacent lots. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,250 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Lot 2, Don Jack Subdivision December 20, 2003 Page 2 of 3 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: Septic tanks must be constructed by a Municipally approved septic tank manufacturer. Lot 2, Don Jack Subdivision December 20, 2003 Page 3 of 3 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. MUMCMAUTY OF Development Services Department / On -Site Water & Wastewater Section Parcel I.D. 020.092.60 Certificate -of On -Site Systems Approval 1. GENERAL INFORMATION Complete legal description DON JACK LOT 2 Phone: 907-343-7904 Fax: 907-343-7997 Expiration Date: q -3d 20W Location (site address) 16435 BETTY CIRCLE, ANCHORAGE, AK 99516 Current property owner(s) CHRISTOPHER MORNET Mailing address Real estate agent Day phone 16435 BETTY CIRCLE, ANCHORAGE, AK 99516 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 SVAX67aftyI_i��MI11=1NAVA Private Well Private Septic Water Storage ❑ Community Well ❑ Public Water System ❑ Day phone TYPE OF WASTEWATER DISPOSAL: Private Septic Holding Tank ❑ Community ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ sg--D' C4!R^sv Waiver Fee $ Date of Payment & /;'Pr/P6'-L6 Receipt Number - ®oqg?y COSA # ®sc *DO lP- Date of Payment Receipt Number Waiver # COVID-19 25% DISCOUNT APPLIED 4 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below; I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based oh the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm FIRST WATER CONSULTING Prone 907-350-9566 { Address 13030 SUES WAY, ANCHORAGE, AK 99516 Engineer's Printed Name CURTIS HUFFMAN, PE Date 6/20/20 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year; quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject toOF Aj ^I,,,11 these various and dynamic characteristics and are outside the control of the evaluator of the P� ' •�� well and septic system. Therefore, any estimate of how long a system will function satisfactory���+ for current or future occupants or guarantee that no unseen encroachments, deficiencies or rI discrepancies exist can be given by First Water Consulting & FWCs *Jtv .. .. 6. DSD SIGNATURE v ...`:: Curtis Huffman System #1 Approved for bedrooms�,. CE 128991 System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, with the following stipulations: By Original Certificate; Date: &- d —26 2D The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other Legal Description: DON JACK LOT 2 If more than 1 septic system on lot: COSA Checklist # _of A. WELL DATA ® Well log is filed with Onsite (or attached) Date drilled 6/6/2004 Total depth 346 ft Cased to 50 ft ® Sanitary seal is functioning correctly ® Wires are properly protected Casing height (above ground) 18+ in. Date of flow test for COSA 6/9/2020 Static water level at beginning of test 49 ft. Well production at time of test 4.2 gpm Comments B. TANK DATA Age of tank(s) 16 years Tank type/material SEPTIC / STEEL Measured operating fluid level in septic tank 49" ® Standpipes/foundation cleanout per record drawing Date of pumping 6/9/2020 D. ABSORPTION FIELD DATA Which system tested (date installed) 6/8/2004 ® ALL standpipes present per record drawing Total measured depth from grade 7.7 ft (max) Measured depth to pipe invert from grade 6.0 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective APPROX. 1.7' INTO THE 2' ED. ® Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: Parcel ID: 020-092-60 Structure served by this system Water storage tank volume NA gallons Well disinfected for coliform test? ❑ Yes ® Nc ® Coliform bacteria is Negative Nitrate mg/L ® Nitrate less than MRL (ND) Arsenic ug/L ® Arsenic less than MRL (ND) FW[:S Collected by Date of Sample 6/10/2020 C. LIFT STATION ❑ Required maintenance completed Age of lift station _ years Lift station material Comments: Adequacy test date 6/9/2020 Results �J Pass For 4 bedrooms Fluid depth prior to test 0 in Water added 600 gal New depth 0 in Elapsed time <1 min Final fluid depth 0 in Absorption rate 600 gpd Any rejuvenation treatment (past 12 months) N If yes; enter date FWcs E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ® Yes if No Community Sewer Manhole/Cleanout > 100' ® Yes if No ft ® Yes if No Neighboring Tank > 100' ® Yes if No ft Private Sewer/Septic Line > 25' ® Yes if No Absorption Field on Lot > 100' ® Yes if No ft Holding Tank > 100' ® Yes if No Neighboring Absorption Fields > 100' if No ft Animal Containment > 50' ® Yes if No ® Yes if No ft ft If septic tank is under driveway comment below Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ® Yes if No ft ® Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ® Yes if No ft Surface Water > 100' ® Yes if No _ Property Line > 5' ® Yes if No ft Wells on Adjacent Lots: ® Yes Absorption Field > 5' ® Yes if No ft Private Wells > 100' ® Yes if No Water Main > 10' ® Yes if No ft Community Wells > 200' ® Yes if No . Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ® Yes if No ft If absorption field is under driveway comment below Property Line > 10' ® Yes if No _ ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' ® Yes if No ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review ,S,. it�. • • �� of Municipal records that the above systems are in conformance '••.�� with MOA COSA guidelines in effect on this date. ; : . 7H ... ,': �� • '. Curtis Huffman f 6,% CE 128991 ..•�c� ®� PROEM* iv� � - , ft ft ft ft ft ft ft ft £I66 -Sb£ L0966 JIV'39V2)OH9NV 3AIdQ 213A0219 60£6 9NIA3A21nS QNVI IlOH L9--VgL 8z 8ZLCL _ LTOZ a38o1DO 30 Mia H1ZT SIHl VNSVIV`39ti80HDNV 1V 031VO '0310N NVHl 83H10 1SIX3 S1N3WHDti08DN3 318ISIA ON ONV S3NIl A183d08d 3H1 NIHIIM 38V N0383H1 031Vn1IS S1N3W3A08dWI 318ISIA 3H1 IVH1 ONV `VNSVIV `13I81SIO 9NI080D38 39680HDNV (LOT -08 Mild )'8nS NDVC NOO `Z 101 A183d08d 038I8JS30 9NIMOIIOd 3H1 30 A3n8nS b 03W80383d 3AVH I iVHl AdI1833 A8383H I 31V0 SIH113S S2i3M300 ON .0£ _ ..L A3MnS llln8-sv z 0 0 0 cn 0 `z rn cn 0 0 '3JI 210/QNV MONS 3AISS3.)X3 01 3nQ 31VWIXO21ddV 38 AVW NO3d3H NMOHS 9NIAVd ANY 'S1N3W3AO21dWI IVNOLLIQQY NOLLISOd 210 53NII A183d02id 3NW21313Q Ol Q3Sl1 38 Ol ION 321V 9NIMVdQ 9IH1 NO 21V3ddV AVW 1VHl S3NI1DN33 :31ON (Q31V.)IQNI S531Nn) NO3d3H NMOHS ION 321V ' 1Vld UO.?3d 9H1 NO 9NI21Y3ddV 330HI NVHI 213HIO'Q2109321 JO SIN3W35V3 '53NI139N33 210'S-LN3W3A02JdWI'S32U11ul1211S IVNOLLIQQV 9NINOI1ISOd dO-q Q35n 38 Ol ION SI QNV -S1N3W3SV3 210/QNV 93NII 101 Q311V1d QNV S32i(11Jnd-Ls 9NLLSIX3 N33M138 S19II3N09 ANY MOHS 01 1,11V0IdI936 SNOLLl11LLSNI 9NIQN31 30 3Sl1 3H1 2103 SI N03213H NOIJ.VW210dNI3Hl 9000£ 3 „Sl .6S 68 N z 0 0 0 m 0 0, o�`euo�ssaJoJ�p G76QV •-.... dA44 a p p �c K69 -Sl i C 110H 'V 3NVHS o - � n Hl 6-b - c G •, • `- `-LIRE f Municipality of Anchorage On-Site Water and Wastewater Program '�i It _,, .e. (907) 343-7904 , /i �,���1 i C'. ETY /4 Se ty Certificate of On-Site Systems Approval \� thQ�- Parcel I.D. 020-092-60 Expiration Date: I —2C I 1. GENERAL INFORMATION Complete legal description Don Jack Lot 2 Location (site address) 16435 Betty Street Current Property owner(s) Lisa & Michael Gray Day phone Mailing address 16435 Betty Street Anchorage, AK 99516 Real Estate Agent Day phone 2. TYPE OF DWELLING: ❑ Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Q Individual 0 Individual Water Storage ❑ Holding Tank 0 Community Class Well ❑ Community 0 Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: Ilan( t7 COSA to be released to the engineer niess otherwise requested by the engineer. COSA Fee $ (p — Waiver Fee $ Date of Payment /b//I//'9 Date of Payment Receipt Number 651396 Receipt Number COSA# Q 5Q -/L.IgD Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone Date 10/18/2017 A 4 OF Lq.4�1�+ 6. DSD SIGNATURE , / •""5" ' 6 System #1 Approved for i bedrooms j Steven•1. �Mn.rie: 'S CE-8149 ;�.:/ System #2 Approved for bedrooms ' s •, �e � 4 Disapproved I�11'` OFEs9.00'� Conditional approval for bedrooms, with the following stipulations: ,ti-okkk III yQQ`.,`�� OF AN (4 =� o�-s\��o �'% 0�%� RA PRof' � • 0,0,, *F6tv► SERv\��S Original Certificate Date: i(r) - L5---1 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. • 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory _ Well Flow Advisory Other • COSA blue sheet r If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: Don Jack Lot 2 Parcel ID: 020-092-60 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 6/6/2004 Sanitary seal (YIN) Y Wires properly protected (Y/N) Y Total depth 346 ft. Cased to 50 ft. Casing height (above ground) lin. FROM WELL LOG AT INSPECTION Date of test 6/6/2004 10/10/2017 Static water level 52 ft. 53 ft. Well production 0.5 g.p.m. 4.0 g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate ND mg/L Arsenic ND ug/L Date of sample: 10/10/2017 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 6/8/2004 Tank size 1250 gal. , Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N/A Date of pumping 7/11/2017 Pumper McDonald's Pumping Service C. ABSORPTION FIELD DATA Date installed 6/8/2004 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 gpd/sf System type trench Length 70 ft. Width 5 ft. Gravel below pipe 2 ft. Total depth 7.8 ft. Eff. absorption area 500 ft2 Monitoring tube Y Depression over field N Date of adequacy test 10/10/2017 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test DRY in. Water added 650 gal. New depth 2 in. Elapsed Time: 180 min. Final fluid depth DRY in. Absorption rate >= 600+ g.p.d. N Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100+ On adjacent lots 100+ Absorption field on lot 100+ On adjacent lots 100+ Public sewer main 75+ Public sewer manhole/cleanout 100+ Sewer/septic service line 25+ Holding tank 100+ Animal containment areas 50+ Manure/animal excrete storage areas 100+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5+ Absorption field 5+ Water main 10+ Water service line 10+ Surface water 100+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water main 10+ Water Service line 10+ Surface water 100+ Driveway, parking/vehicle storage 10+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS G. ENGINEER'S CERTIFICATIONct,OF ALI 4 k I certify that I have determined through field inspections and de C0:• 1; �,� review of Municipal records that the above systems are in # •! %' *�40 conformance with MOA COSA guidelines in effect on this date.` ,w•••• P Engineer's Printed Name Steven Pannone ":Sleveri k*'aririone: e Date 10/18/2017 ����yy• CE-8149 . i k COSA canary sheet_2-6-15.doc Municipality of Anchorage d On -Site Water &Wastewater Program (907)343-7904 b102 9 0 JdW CERTIFICATE OF ON-SITE SYSTEMMI-OP", Pgtp Parcel I.D. 020-092-60 Expiration Date: CJ�� Z//_ 1. GENERAL INFORMATION Complete legal description DON JACK S/D; LOT 2 Location (site address) 16435 BETTY STREET, ANCHORAGE, AK, 99516 Current Property owner(s) GEOFFREY LUNDFELT Day phone Mailing address Real Estate Agent 16435 BETTY STREET, ANCHORAGE, AK, 99516 JENNIFER SCHULENBERG WI REMAX Day phone 2. TYPE OF DWELLING: 0 Single Family (wlwo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: 360-8912 229-4319 TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site I_I Public Water System ❑ Public Sewer ❑ WaivenVariance request for: Distance: Received by: Date: r C COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5ab Waiver Fee $ Date of Payment S�iDI �� Date of Payment Receipt Number 043"316 Receipt Number COSA #C_ IW/6 � Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, i verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms'and type of structure indicated herein. /further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, Engineer's Printed Name Engineefs Comments: JEFFREY A. GARNESS, P.E. In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and ,septic systems depend on the local soils condition, groundwater levels that may _ fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there am no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MCA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 6. DSD SIGNATURE -32 I% System #1 Approved for bedrooms. _ System #2 Approved for bedrooms. Disapproved. Phone 337-6179 99507 Date i S r4 oo600p�0 P:.4 T . I �Q � ff�ey�i G rness:' G ° ICE -79 3 �O Conditional approval for bedrooms, with the following stipulations: OF O i Jam' ON-SITE �� r WATER AND r" J� WASTEWATER o1 Original Certificate Date: :f �2 The Municipality or Anchoxe Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approvai (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist f/ Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other tri— ivnni If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: DON JACK S/D; LOT 2 Parcel ID: 020-092-60 'BEDROCK @ 43'. "24" ABOVE ACTUAL GRADE. WELL IS PROTECTED BY RETAINING WALL AND EXTENDS A. WELL DATA 12"+ABOVE ARTIFICIAL GRADE AT RETAINING WALL. "'WELL HYDROFRACTU RED AFTER INSTALLATION. Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) YES Date completed 6/6/2004 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth 346 ft. Cased to `50 ft. Casing height (above ground) *10+ in. FROM WELL LOG AT INSPECTION jZf 4 -l' - Date of test Static water level 6/6/2004 52 ft. Well production 0.5 WATER SAMPLE RESULTS: Coliform O colonies/100 ml. Arsenic: mug./L. B. SEPTICIHOLDING TANK DATA 4/1 812 01 4 g.p.m. ...4.85+ g.p.m. Nitrate N� mg./L. Date of sample: 4/18/2014 Collected by: GEG, Ltd. Tank Type/Material SEPTICISTEEL Date installed 6/8/2004 Tank size 1250 gal. Number of Compartments 3 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) NIA Date of pumping 2/4/2014 Pumper A+ HOME SERVICES C. ABSORPTION FIELD DATA 'BELOwEXISTING GRADE Date installed 6/8/2004 Soil rating .p.d./ or ft2/bdrm) 1_2 System type TRENCH Length 70 ft. Width 5 ft. Gravel below pipe 2 ft. Total depth '7.8 ft. Eff, absorption area 500 ft2 Monitoring tube YES Depression over field " NO Date of adequacy test 4/18/2014 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 3 in. Water added 680 gal. New depth"4 in. Elapsed Time: = min. Final fluid depth"4 in. Absorption rate >= 600+ g,p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date "LAST 605 GALLONS CAUSED NO RISE IN LIQUID LEVEL. 100% ABSORPTION. D. LIFT STATION Date installed "Pump on" level at in. Size in gallons Manhole/Access (Y/N) "Pump off"level at we er alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots Absorption field on lot 100'+ On adjacent lots 100'+ 100'+ Public sewer main N/A Public sewer manholelcleanout N/A Sewer /septic service line 25'+ Holding tank NIA Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main NIA Water service line 101+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 104 Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date (Rev. 10112/12) Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcell.D. 020-092-60 COSA#�L'/�1�13 1. GENERAL INFORMATION Expiration Date: Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address DON JACK S/D; LOT 2 16435 BETTY STREET * ANCHORAGE. AK * 99516 DANE BANDELL Day phone 16435 BETTY STREET * ANCHORAGE, AK * 99516 Day phone NANCY BERGH POLLOCK W/ PRUDENTIAL Day phone 529-8940 563-5500 3801 CENTERPOINT DRIVE, #200 * ANCHORAGE, AK * 99503 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well E Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site N Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. i further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE VGNApproved for —4— bedrooms. Disapproved. Phone 337-6179 Date 6 11 IZ �06�0 Q 4 ..i QO P '•, ff ey A. arness,- Q P CE 3.' 1 0� �04en Pro re ss'W'6 �004000�� dl'. %o(cOFAti1f Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory l✓ Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Nitrate Advisory Other By: lit/:oma % (Rev. 11105) ON-SITE WATER AND WASTEWATER PROGRAM Original Certificate Date: ( — 5 , /2 Municipality of Anchorage Development Services Department = "` Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: DON JACK S/D; LOT 2 Parcel ID: 020-092-60 *BEDROCK AT 43'. **WELL WAS HYDROFRACTURED AFTER INSTALLATION. ***24+" ABOVE ACTUAL GRADE. WELL IS A. WELL DATA PROTECTED BY RETAINING WALL AND EXTENDS 12+" ABOVE ARTIFICIAL GRADE CREATED BY RETAINING WALL. Well type PRIVATE If A, B, or C provide PWSID# N A Date completed 6/6/2004 Sanitary seal (Y/N) YES Total depth 346 ft. Cased to *50 ft. FROM WELL LOG Date of test 6/6/2004 Static water level 52 ft. Well production 0.5 — 9 -p.m - WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Arsenic: IND ug./L. B. SEPTIC/HOLDING TANK DATA Nitrate ND mg./L. Well Log (Y/N) YES Wires properly protected (YIN) YES Casing height (above ground) ***24+ in. AT INSPECTION Date of sample: 5/23/2012 Tank Type/Material SEPTIC/STEEL 5/25/2012 31 ft, **5.63 Collected by: GEG, Ltd. Date installed 6/8/2004 Tank size 1250 gal. Number of Compartments E Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (Y/Nf) NO c High water alarm (Y/N) N/A Date of pumping Pumper n C 5+ p e S C. ABSORPTION FIELD DATA *BELOW EXISTING GRADE Date installed 6/8/2004 Soil rating .p.d./ r ft2/bdrm) 1_2 System type TRENCH Length 70 ft. Width 5 ft. Gravel below pipe 2 ft. Total depth *7.8 ft. Eff. absorption area 500 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 5/25/2012 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 1_5 in. Water added 930 gal. New depth **2 in. Elapsed Time: **– min. Final fluid depth **2 in. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date **LAST 690 GALLONS CAUSED NO RISE IN LIQUID LEVEL. D. LIFT STATION Date installed Size in gallons Manhole/Access (YIN "Pump on" level at in. "Pump off' level High water alarm level at Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main N/A Sewer /septic service line 25'+ Public sewer manhole/cleanout N/A Holding tank F1 Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. -ENGINEER'S CERTIFICATION_ off` . • gSQ4o 1 certify that 1 have determined through field inspections and a : 4 �ao0� review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this ....... • . • , date. Qp f rey Garness. 0 Engineer's Printed Na7 e JEFFREY A. GARNESS 04� C 3 It 12.•'�co�o Date �earrna «ton°� o COSA Fee $ `Y `Z G Date of Payment Receipt Number (Rev. 11105) Waiver Fee $ Date of Payment Receipt Number SGS SGS Ref.# 1121808001 Client Name Garness Engineering Group, Ltd Project Name/H Don Jack Lott Client Sample ID Don Jack Lot2 Matrix Drinking Water Printed Dateflime Collected Date/Time Received Date/Time Technical Director 05/31/2012 16:22 05/23/2012 16:00 05/23/2012 16:34 Stephen C. Ede Parameter Results LOQ Units Method Container ID Allowable Limits Prep Analysis Date Date In@ Private Individual Analysis Magnesium 10200 50.0 ug/L EP200.8 C 05/29/12 05/29/12 NRB Manganese 4.41 1.00 ug/L EP200.8 C (<50) 05/29/12 05/29/12 NRB Nickel ND 2.00 ug/L EP20Q8 C (<100) 05/29/12 05/29/12 NRB OH Alkalinity ND 10.0 mg/L SM21 2320B D 05/26/12 AYC pH 7.90 0.100 pH units SM21 4500-H B D (6.5-8.5) 05/26/12 AYC Selenium ND 5.00 ug/L EP200.8 C (<50) 05/29/12 05/29/12 NRB Silver ND 1.00 ug/L EP200.8 C (<100) 05/29/12 05/29/12 NRB Sodium 11000 500 ug/L EP200.8 C (<250000) 05/29/12 05/29/12 NRB Sulfate 12.9 0.100 mg/L EPA 300.0 D (<250) 05/30/12 05/31/12 SDP Total Dissolved Solids 155 10.0 mg/L SM21 2540C D (<500) 05/27/12 AYC Zinc 6.15 5.00 ug/L EP200.8 C (<5000) 05/29/12 05/29/12 NRB Arsenic ND 5.00 ug/L EP200.8 C (<10) 05/29/12 05/29/12 NRB Thallium ND 1.00 ug/L EP200.8 C (<2) 05/29/12 05/29/12 NRB a SGS ReLN 1121808001 LOQ Units Client Name Garness Engineering Group, Ltd Printed Date/Time 05/31/2012 16:22 Project Name/9 Don Jack Lott Collected Date/Time 05/23/2012 16:00 Client Sample ID Don Jack Lot2 Received Date/Time 05/23/2012 16:34 Matrix Drinking Water Technical Director Stephen C. Ede Sample Remarks: Parameter Results LOQ Units Method Container ID Allowable Prep Analysis Limits Date Date Init Metals by ICP/MS AYC Aluminum ND 20.0 ug/L EP200.8 C Hardness as CaCO3 127 5.00 mg/L SM21 2340B C 05/29/12 05/29/12 NRB Waters Department (<6) 05/29/12 05/29/12 NRB Barium 35.5 3.00 ug/L Total Nitrate/Nitrite-N ND 0.100 mg/L SM21 4500NO3-F B 05/30/12 AYC Microbiology Laboratory EP200.8 C (<5) 05/29/12 05/29/12 NRB Calcium 34300 E. Coli Negative 1 100mL SM21 9223B A 05/23/12 DLC Total Coliform Negative 1 100ml, SM21 9223B A 05/23/12 DLC Private Individual Analysis Alkalinity 134 10.0 mg/L SM21 2320B D 05/26/12 AYC Aluminum ND 20.0 ug/L EP200.8 C 05/29/12 05/29/12 NRB Antimony ND 1.00 ug/L EP200.8 C (<6) 05/29/12 05/29/12 NRB Barium 35.5 3.00 ug/L EP200.8 C (<2000) 05/29/12 05/29/12 NRB Cadmium ND 0.500 ug/L EP200.8 C (<5) 05/29/12 05/29/12 NRB Calcium 34300 500 ug/L EP200.8 C 05/29/12 05/29/12 NRB Chloride 1.78 0.100 mg/L EPA 300.0 D (<250) 05/30/12 05/31/12 SDP Chromium ND 2.00 ug/L EP200.8 C (<100) 05/29/12 05/29/12 NRB CO3 Alkalinity ND 10.0 mg/L SN 21 2320B D 05/26/12 AYC Conductivity 291 1.00 umhos/cm SM212510B D 05/26/12 AYC Copper 24.7 1.00 ug/L EP200.8 C (<1300) 05/29/12 05/29/12 NRB Fluoride ND 0.100 mg/L EPA 300.0 D (<2) 05/30/12 05/31/12 SDP HCO3 Alkalinity 134 10.0 mg/L SM21 2320B D 05/26/12 AYC Iron ND 250 ug/L EP200.8 C (<300) 05/29/12 05/29/12 NRB Lead 0.219 0.200 ug/L EP200.8 C (<15) 05/29/12 05/29/12 NRB w m 0 M� w 0 n 9 Y 1 1 1 1 1 � 'mer // 0'07 `5b /G:*, ao to O t M` td O O w c C� .1� w m 0 M� w 0 n 9 Y 1 1 1 1 1 � 'mer // 0'07 `5b /G:*, ao to O t M` td O O w