Loading...
HomeMy WebLinkAboutSKY RANCH ESTATES #1 BLK 5 LT 6Sky Ranch Estates #1 Block 5 Lot 6 #015-301-32 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP231212 Work Type: Septic Renewal Tax Code Number: 01530132000 Site Legal Address: SKY RANCH ESTATES #1 BLK 5 LT 6 G:2737 Site Mailing Address: 11971 STEEPLECHASE CIR, Anchorage Owner: BUETTNER JOHN H & DOREEN B Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date: Expiration Date »lent U � Department Lot Size in Sq Ft: Total Bedrooms: 7/25/2023 7/24/2024 16417 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 4 • A test hole is required prior to construction of the absorption field, in the location shown on the site plan, to confirm minimum separation to impermeable soil and seasonal high groundwater, as well as percolation rate. Construction may proceed at your own risk prior to 7 -day groundwater monitoring. If results require a design change, construction shall stop pending approval of a change order. Please submit results with the inspection report (or change order, if required). Received By: SS �� 7� ��� Date: Issued By: Date: MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-301-32 Property owner(s) John & Doreen Buettner Mailing address 11971 Steeple Chase Cir Site address same Day phone Legal description (Sub'd., Block & Lot) Sky Ranch Est #1 B5 L6 Legal description (Township, Range & Section) Lot Size 16,417 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑x Initial ❑ Single Family (SF) ❑x (w/wo ADU) Septic Tank ❑x Upgrade pg ❑ �9uplex (D) El Holding Tank El Renewal ❑x Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: 731 6s Permit No. 0 S P Z 3 (Z j 2 Permit App_'- : ,' . c Waiver Fees: Date of Payment: Receipt Number: Waiver No. Pannone Engineering Services LLC Steven R. Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com Mailing: P.O.Box 1807, Palmer, AK 99645 Telephone: (907) 745-8200 FAX: (907) 745-8201 17 July 2023 Subject: Sky Ranch Estates #1 B5 L6 Upgrade Septic System Permit Renewal This is a request to renew the permit for the above-mentioned lot. All site conditions remain the same. The proposed installation will not affect the future development of this or the surrounding lots. If you have any questions or concerns, please contact me at 745-8200. Sincerely, SRP Steven R. Pannone, P.E. Owner/Civil Engineer Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231212, Curtis Townsend, 07/25/23 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.arg/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP221234 Work Type: Septic Upgrade Tax Code Number: 01530132000 Site Legal Address: SKY RANCH ESTATES #1 BLK 5 LT 6 G:2737 Site Mailing Address: 11971 STEEPLECHASE CIR, Anchorage Owner: BUETTNER JOHN H & DOREEN B Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Rf Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date ,Z�»Lnr 09`5_n llepartment 7/14/2022 7/14/2023 Lot Size in Sq Ft: 16417 Total Bedrooms: 1-41' IGI� ❑ Private Well ❑ Water Storage All construction'shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: • A test hole is required prior to construction of the absorption field, inthe location shown on the site plan, to confirm minimum separation toimpermeable soil and seasonal high groundwater, as well as percolation rate. Construction may proceed at your own risk prior to 7-daygroundwater monitoring. If results require a design change, constructionshall stop pending approval of a change order. Please submit results withthe inspection report (or change order, if required). CO -# j n e5 yA +0 15 .bed boom S. 7�Z5�Z2 CO -&2 0J Y/z,�9/2-3 Received B) Issued By: Date: Date: i Z MUNICIPALITY F ANCHORAGE Community Development Department '' Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-301-32 Property owner(s) John & Doreen Buettner Mailing address 11971 Steeple Chase Cir Site address same Day phone Legal description (Sub'd., Block & Lot) Sky Ranch Est #1 B5 L6 Legal description (Township, Range & Section) Lot Size 16,417 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS -AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X Septic Tank ❑X Upgrade ❑X (w/wo ADU) Holding Tank El ❑ (D) Renewal ❑ Renewal Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. koiyiidtuie V1 Property owner or autnonzea agent) Permit/Rush Fees: At 95.E Waiver Fees: Date of Payment: cp�� ��an� a Date of Payment: Receipt Number: (0G Receipt Number: Permit No. 0SP' 22 12 -3 Y Waiver No. Permit App__ -:•:L. c Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221234, Deb Wockenfuss, 07/14/22 FTI cn— MUNICIPALITY OF ANCHORAGE ADVANCED WAST EWATER TRE A TMENT SYS'T'EM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this / I Day of 1, of 20,), A, by and between -Do,� , herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment S stems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as Advantex system located at (legal description) Sky Ranch Est #1 B5 L6 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). /� Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential . failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 A6 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. I�Y2 Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date ,of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: By: ��'c1y,�,4�.LG1 (signature) Date: I,/ AZ 30YC'('N 'Rue -Hiles (print name) STATE OF ALASKA ) ss. THIRD JUDICIAL. DISTRICT ) The foregoing instrument was acknowledged before me this day of -� 20 ? by oU' 0. 1 �o ✓L9 D A DF�O NOT P FOR ALAS My Commission expires: 7e,,jt4c ' 8 yf f- .0y pvlk`- 4 �%�-f,- ION a1' i. IVIUNICTP£ALITY• ,lF, A` By: (signature) (print name) (rev. 05/18/2018) Date: �Z Z Title: Page 3 of 3 Municipality of Anchorage �T Development Services Department Building Safety DMsion It _ Onsite Water S Wastewater Program, 4700 South Bragaw St P.O. Box 196650 Andtorege, AK 99519-6650 www.d.andtorage.ak.us (907) 343-7904 Pogo 1 of 3 Onsite Wastewater Disposal System and/or Well Inspection Report Permit Number. SWO10353 PID Number. 015-301-32 Name:RON BUSS Wastewater System: 0 New ■ Upgrade Address: 16644 VIRGO AVE, ANCHORAGE, AK 99516 ABSORPTION FIELD IS Phone: No. of Bedrooms: (907) 345-4511 4 ODeep Trench OShallow Trench OBed OYound ■Other LEGAL DESCRIPTION s' "`"a 2.0 Tom Depth "� ° 3.s -5.0 CpD/se. rt rL Lot: Block: Subdivision: Depth to Woe bottom fmm .dglmel word- Crmel depth bwweplh P%w 6 5 SKY RANCH EST. #1 1.6-2.6 FL 0.28 rL Township: Range: Sectlon: fv edd.a shows rtsi^at Ped. Crewel bnsna - - - SEE DRAWING rL 60 rL WELL: 0 New 0 Upgrade uew batt. 5 3 Ifienber ofX1.67 Anew n R CkrriGootbn &B.0; Told Coved To Total abompOon ones: 300 pipe moW oh D 3034/ F-810 Fl. FL sown Diwn Dab orWS stoup Mater tewh W~. A+ HOME SERVICES Dep NeloMd: 9/20/2001 Ft. YW: " sat Ah Joe" "In Aho" Cnxo TANK CPM nFL SEPARATION DISTANCES OSeptic OHolding ■SIMP. OOther To From Sept Tank Abso Oon M`id Uft Station Holding Tank /Prhate sewer unea Yow wti .. ANCHORAGE TANK cop-A4 In ewl— 1500 Well 100'+ too'+ — — 25'+ rata. STEEL taeraer w eanvonmeetc 2 Surface water 100'+ too'+ — — — LIFT STATION Lot Una 5'+ a5'+ - - - Sts In askewrwwreahown 1500 ANCHORAGE TANK ORENCO SYSTEMS Foundation 5'+ 10'+ - - - en bnef ah levet a: High eater mann eu TIMER TIMER 46" Curtain Drain NONE KNOW rehe a roan a.cutool Inepeatla^• p« oohed M /20 OSI 05 HHF M.O.A. Remarks: BENCH MARK leeelbn .w Dee""M -*LOT UNE WAIVER WRO10070. TOP STEP NEAR NORTHEAST CORNER OF HOUSE. -OLD SEPTIC TANK WAS ABANDONED PER THE UPC. A�„nwd ae,ohera 100.00 rt fl10e11MM WAL QgOd00� 0 Inspections performed by AWWC, INC. Dates: Ist 9/20/01 2nd 9/20/01 • .A 9/20/01 ... .. 0 ADO 4th 9/21/01 , }f me.. 953 Department of Health and Human Sery as approval 10' .:q`��vo ed and d by: /J / Date: Re viapprove o ��OQO rofesslo a� a Oppoo PERMITNUMBER: SW010353 SWO AS -BUILT DRAWING PID NUMBER: 015-301-32 015 V COI 50.9 26.3 /� \\ STI 53.4 28.1 NEW 1500 GALLON ST2 59.9 32.2 \ S.T.E.P. TANK WITH DUAL ounErs MH 62.0 33.7 —\ \ MT1 MT2 23.2 47.7 38.8 819 \ EXISTINGSYSTEM TO BEUSEiA .�' NEW DRAINnELD =E—rt / 19 HII NR COMPRESSOR 10' UTILITY EASMENT .--_col FAIR LINE EXISTING FOUR BEDROOM HOUSE .Yn STEEPLE CHASE CIRCLE ALASKA WATER & WAST NNIATER CONSULTANTS, INC. MI OFBARR ROAD. MTE PB • ANCHORAGF. AK 9950.' FHONE (907)357-6179 • FAX (907)55"24 :PARED FOR: PHONE NUMBER: RON BLISS (907) 351-4511 SKY RANCH ESTATES AL1; LOT 6. BLOCK 5 OF WORK: AS—BUILT OF SEPTIC SYSTEM UPGRADE (BI K.D.W. p C ate, 2OF3 1 10 1 NUMBER: AS PARCEL ID : SWO -BUILT DRAWING 1 I SWO1O353 015-301-321-32 TOP OF TANK AT INLET — 89.98 INVERT OF BUNG AT INLET - 89.4 FINAL GRADE 95.4-95.7 mMH II NSW 1500 6 U.ON 5.f.U. TANK ORIGINAL GRADE 94.9-95.95 TOP OF SAND - 93.06 NR UNE - 91.46 - 90.95 rA �� ALASKA WATER & WASTEAVATER CONSULTANTS, INC. r.9n1 n AW ones CIRF 731 • �GF. M 99SN. • RIo1E M71137�179 • FU 7907753E-326 RON BLISS (907) 351-4511 LL DESCRIPTION: SKY RANCH ESTATES #1; LOT 6. BLOCK 5 OF WORK: PROFILE AS -BUILT OF SEPTIC SYSTEM UPGRADE (BO FINAL GRADE 96.2-98.5 INSULATION -FILTER FABRIC K.D.W. N.T.S. NUMBER: 3OF3 TOP OF TANK AT OUTLET - 89.93 INVERT OF DISTRIBUTION LINES - 93.34 09/24/2001 10:57 FAX 9078686770 A+ Home Services. Inc. fM001 1 u) Z-13-7 .Page, s of 13 INSPECTION REPORT MUNICIPALITY OF ANCHORAGE - BUILDING SAFETY DIVISION 4700 S0Lrn1 BRAGAW STREET, ANCHORAGE, ALASKA INSPECT7ONS. Voice:. (907) 343-8300 'ar_(907) 249-7777 INFORMATION._ (407) 343-82111 N"Ll.- EDS FIXCTWC PERMITNuArz;ER: 01-8872 .1 ADDRESS: 11971 STEEPUCHASECRCLE. DATE: 9/24101 PHONEW. 272-4591 PHONE 02: LO7. 6 BLOCEi'S SUBDHUTOh Sl,-YRANCH ESTATES #1 COMMENTS AM -CALL TO BE MET ON SITE F TYPE OF 02: AL INCPEC77ON.• Electric4l Final �j Nonoa-cwmpliartccobaervcd. [] Do not conceeluntil re-nspeued. ❑ C.O.approWdak,. [] Corrections essential as explained below. Will re-examine at next Inspection. ❑ C.C.O. approved (carbartsbelow). I ❑ NPDFS (Stormwater) -- `- - CO1i VZNM Reinspection? ❑ S '-f'IC.r iYS ► t1 �l-��Rlc �- U0TxPLeRo0[Jp1 �UdN/, � FINArI_ P�f'I�t2o��J, 1� DVSPECM11- I' 11 clor� L. ,, p F- W DATE: dq— n I !7 �, —O I ❑ Stormwater tr entplan/spec, on site. f \G ❑ Stonnwatu treatment implemented [ ❑ Sftdoffche drainage Mot being controlled ❑ InsWVcorred straw biles. ❑ Inlallfcorrectsilt fences. 0 other bee mansgementpnnkesonsite/naded ❑ See attached detailed notesPmontctiona. ❑ Failure to comply mavfmk in tines. EJ .i Take action now. ❑ Reinspection will be made on: ❑ Redirect flow. Report Siven lo: Company. WHEN CORRECTIONS ARE MADE, PLEASE CALL FOR INSPECHOAr t65t DO NOT REMOVE 7THS NO77CE MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water& Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Permit Number: SWO10353 ViO/v / //'36A -M o -o -K -S A3 -A",; d.0 Date Issued: Sep 04, 2001 Expiration Date: Sep 04, 2002 Parcel ID: 015-301-32 Legal Description: SKY RANCH ESTATES #1 BLK 5 LT 6 Design Engineer: 0041 AK Water & Wastewater Consultant Site Address: 011971 STEEPLE CHASE CIR Owner Name: Ron Bliss Lot Size: 16417 SO. FT. Owner Address: 11971 STEEPLECHASE CIR Total Bedrooms: 4 Permit Bedrooms: 4 ANCHORAGE. AK 99516-2321 This permit is for the construction of. Disposal Field Q Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By Issued By Date: Date: / _¢ —Ql Municipality of Anchorage Development Services Department Building Safety Division Onsite Water & Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ek.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcell.D. 015-301-32-000 Permit Number SWO1033-3 Property owners) RON BLISS Day phone 345-4511 Mailing address (1) 11,1, '/1/ VrP-tro Atr_. c Ary- SMalling address (2) / / 2 7 / Ste e n lr Llia s< �'' i - Zip code 9 !o Legal description (Lot, Block & Sub'd.) . SKY RANCH ESTATES f 1: LOT 6. BLOCK 5 Legal description (Section, Township S Range) N LA Lot Size .46, t -// ZZ Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms 4 Sewer Only ❑ Well Only ❑ Sewer and Weil ❑ Water Storage ❑ Sewer Upgrade 0 THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is cor'ecL I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. ALASKA WATER do WASTEWATER CONSULTANTS, INC. (Signature of preperty owner or authorized agent) Permit Fees: A 30)0 . oc� Date of Payment g/ b I Receipt Number. 96 to S Waiver Fees: A I i's cc, Date of Payment g o O Receipt Number. wV O1007D ALASKA WATER & WASTEWATER CONSULTANTS, INC. August 16 , 2001 Municipality of Anchorage Development Service Department Building Safety Division On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Septic System Upgrade for Lot 6, Block 5, Sky Ranch Estates #1 (Bottomless Intermittent Sand Filter - ISF) To whom it may concern: The existing 4 bedroom house is served by a private well and septic system. The existing septic system consists of a 1250 gallon septic tank and a deep type drainfield. The drainfield is surcharged and must be upgraded. We are proposing that a 1500 gallon S.T.E.P. tank and a innovative 5 -wide Bottomless Intermittent Sand Filter (ISF) system be installed. Comments regarding the upgrade are summarized as follows: 1. GENERAL: A test hole was excavated on the north half of the property to determine an area suitable for a septic system upgrade. Given the limited space available, it is our opinion that a Bottomless ISF system is the most viable option. 2. SOILS: Attached are logs which shows the soil classifications, groundwater monitoring, and the percolation test results. It is our opinion that due to the overall appearance of the soils, a application rate of 2.0 gallons/day/0 should be used for the Bottomless ISF.I 3. DRAINFIELD DESIGN: Bottomless Intermittent Sand Filter (ISF) a. Percolation Rate: 8.6 minutes/inch b. Allowable Application Rate for ISF: 2.0 gallons/day/R2 c. Number of Bedrooms: 4 d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 300 0 f. Effective Depth below pressure pipes: 2.5+ inches g. Width: 5 feet h. Length: 60 feet. 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com i. Effective absorption area = 300 R2 j. Air Supply: Thomas Industries, Model 5070, "Anchorage Tank". k. Air Supply Line: "Wasteflow" emitterline,1/2 inch I.D, "Anchorage Tank". 1. Sand Material: In accordance with M.O.A. latest standards m. Pea Gravel: 100% passing 3/8" sieve, less than 20% passing the 1/4" sieve, and less than 1% passing the #8 sieve. We are proposing to excavate down to a depth of 4 feet (maximum), place a minimum of 6 inches of sand, install the air supply line, and cover it with 1.5 feet of sand. On top of the sand, we will place 6 inches of 3/8 inch pea gravel, with the pressure laterals midway in the layer. We will use a conventional lift station (Anchorage Tank), equipped with a programmable timer so that flow can be intermittently dosed to the ISF. 4. SURFACE WATERS: There is no surface water within a 100 foot of the the proposed septic system upgrade. 5. TOPOGRAPHY: As can be seen on the attached topography site plan, there are no slope concerns. 6. LOT LINE WAIVER: We request that you issue 0 foot lot line waiver to the proposed drainfield. There are no impacts on any adjacent properties with the granting of this waiver. 6. MATERIALS AND CONSTRUCTION PRACTICES: The materials used, and the construction practices will comply with the M.O.A. "Intermittent Sand Filter Design, Installation & Maintenance Manual". The contractor should read this document prior to construction. Copies are available at the Municipal Onsite Services office (4700 South Bragaw). 7. CLOSING: I am open to any suggestions from your department, which would be an improvement to the proposed design. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact me at 337-6179. Thank you for your assistance. P.E., M.S. 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwwc.com 1 1 I , I -- ------ --------- --- ------------------ ------ - - --- i — --- ``\ 'KY RANCH ESTATES Sk)' LOT 9 BLOCK 41 Lor4h \\ ♦ i ee'04 /0lee:r=-- 4 ' i I'/ i � • "'SKr � � i � *� o . / 1 ♦\ i � �`♦ 17 g% \ K 1 *N / SKY RANG EVATES SKY RANCH ESTATESI ���"' \ �_�♦`i \- /..--�'� LOT 2 BLOCK S LOT T BLOCK S SKRANCH ESTATES // \ EXISTING I/ LYSEPTIC l0T BLOCK—S I Q i �SYSTEM !.� SKY RANCH ES�ATF`S �\ ♦ /t' LOT 4 BLOCK S \C \ fits b ��� T` / ♦\ PROPOS SEPTIC SYSTEM \ I m 1 (SEE DESIGN PACE 2 OF 3) \ 1 • ------ j SI(Y RANCH STATES 1 1 - ` T� LOT S BL"S SKY RANCA ESTATES / NG `\ 4 BEDROOM HOUSE !' F :RM1CH ESTATES ioT ,z BLOCK s C . \ THAs LEN— SKY RANCH ESTATES `�-- —��� SKY RANCH ESTATES I � LOT t; BLOCK S SKY RANCH ESTATES LOT 8 BLOCK S , SKY RANCH ESTATES \\ LOT 10 BLOCKS LOT 9 BLOCK S I , I , I 1 1 1 r ` X8/15/2001 t/!1e!1K1n DRAWN r1� ALASKA V�ATER & MASTI;WATER C.J.G. ' Ste' *�' CONSULTANTS. INC. 6001 OEBARR ROAD. 9U7E EB • ANCHORAGE, AK "504O4 • PHONE os n4no •EAR Tu3eat4e 1M = 100• p' t ••• ••••.YA G� PREPARED FOR PHONE NUMBER: PAGE NUMBER: RON BLISS 345-4511 1 1 OF 3 t ey Gornessr yy a ., CE 953 ndProfessioOo\��'�' LEGAL DESCRIPTION: SKYINCH ESTATES1: LOT 6, BLOCK 5 TYPE wo SITE PLAN FOR SEPTIC SYSTEM UPGRADE AIR COMPRESSOI SHALL BE LOCATED VMITN BASEMENT OR THE GARAGE. THE COLTRACTOR L PROVIDE A 0-10 PSI PRESSURE GAUGE AT A TDN WHICH IS READILY ACCESSIBLE FROM IN THE HOUSE. 111TFa A 30 PSI GAUGE WILL WORK AIR COMPRESSOR SHALL BE A THOMAS STRIES MODEL 3070, AS SUPPLIED BY MAGE TAW(. THE AIR LINE SHALL BE 1/2 DIA HDPE Q PIECC), INSULATED WITH M FOAM PIPE WRAP 6M3 VALUE). V40C A 2 SCH40 PVC JACKET. THE LIE SHALL BE ED TO A KIM" DEPTH OF 3 FEET. CONTROL PANEL FOR THE STEP TANK SHALL BE ALLED ON TIE OUTSIDE OF THE HOUSE WITH A RLE/VISUAL INDICATOR ON THE INSIDE OF M \ ' / NOTE: THE CONTRACTOR SHALL HAVE THE 100' WELL RADII SHOWN, THE WEST LOT UNE, THE NORTH LOT LINE, AND THE 10' / UTILITY EASMENT FLAGGED BY A REGISTERE LLA PROPOSED S -WIDE BOTTOMLESS INTERMITTENT SAND FILTER (ISF). EXCAVATE A TRENCH THAT IS S FEET DEEP MAXIMUM BY S FEET WIDE BY 60 FEET LANG. SEE DET/ 1 AND PROFILE (PACE 3 OF 3) 10l uTILITY EASMENT Aj k EXISTING OOM 0' LOT UNE + HOUSE WAVER REOUE 0. ��r I A L S� I\ I STEEPLE CHASE CIRCLE ALASKA WATER & WASTEMIATER CONSULTANTS, INC. 901 OEBARR ROAD. SUITE R • ANGNORAGE. AK 09504 • DIME (907)137-0170' FAX (907133"24 EPARED FOR: PHONE NUMBER: RON BUSS (907) 351-4511 :AL DESCRIPTION: SKY RANCH ESTATES #1; LOT 6, BLOCK 5 'E OF WORK: DESIGN OF PROPOSED SEPTIC SYSTEM UPGRADE (BOT I -NR LINE\ \ (SEE NOTE) EXISTING SEPTIC SYSTEM TO BE USED AS A / RESERVE SITE i 'LACE EXISTISTWG 1250 LLON SEPTIC TANK WITH A NEW 1500 GALLON S.T.EP. TANK WITH DUAL. OUTLETS —NR COMPRESSOR\ (SEE NOTE) \ LL FOUNDATION \\ CLEANOUT TANK IS TO BE 5'+ FROM DRNNFlELD TANK IS TO BE 5'+ FROM LOT UNE 8/16/2001 AWN BY. C.J.G. ALL, 1 " = 30' CE NUMBER 2 OF 3 5 2 I t L DISTRIBUTION LINES. PIPE SIZE AND HOLE SPACING PER ANCHORAGE TANK/ORENCO SYSTE ORIGINAL Ed s s� 2 FEET MINIMUM FROM AIR COMPRESSO .__________________ __Q1 LONG _I DIA. SCH. 40 PVC LATERALS S. SHIELDS. AND FLUSHING /ES PER ORENCO DESIGN) rFINAL GRADE V OF ALASKA NVATER & WASTEWATER a CONSULTANTS, INC. 6901 DEBARR ROAD WTE !B • AWHORAGE AK 94504 • PHONE 407 57-0170 - VAX 0="266 PREPARED FOR: PHONE NUMBER: PA RON BUSS 351-4511 LEGAL DESCRIPTION: SKY RANCH ESTATES SUBDIVISION J11; LOT 6, BLOCK 5, TYPE OF WORK: PROFILE DRAWING OF SEPTIC SYSTEM UPGRADE (BOTTOM INSULATION -FILTER FABRIC — OX OF PEA GRAVEL UNDER DISTRIBUTION ONES C.J.G. N.T.S. NUMBER: 3 OF 3 ISF) A. A S.T.E.P. I TANK ALASKA WATER & WASTEWATER CONSULTANTS, INC. • (907938-4246 SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: SKY RANCH ESTATES /1; LOT 6, BLOCK 5 PERFORMED FOR: RON BUSS DATE: 8/13/01 (feat ORC EST HOLE #11 1 7 8 9 10 11 12 13 14 15 16 17 18 SM/ML DEPTH TO GROUNDWATER DATE DRY SM SOIL CLAS it ON 8413/91 \\ S za 01 6- — 2 1:46 30 2- 4- 3 1:46 GW :Zzzz•- — 4 1:56 30 1 1/2- 4 1/2- 5 I11111111ML 6- — I \ 2:06 I��III".11GM SKY RANCH ESTA 4 1/4- LOT 7 QLOCK 5 111,01111 — EX N 4 BBEDROCAI J SITE PLAN _ HyVSE GC N/HN•CL OL 3 3/4- j 2:16 — 6- — IIIIIIIII MH 30 2 1/2- 3 1/2- 11 2:26 SP 6- CH 12 1 2:36 30 1 2 1/2- 7111i11i • SC 7 8 9 10 11 12 13 14 15 16 17 18 SM/ML DEPTH TO GROUNDWATER DATE DRY 8/8/01 DRY 8413/91 \\ S za 01 6- — DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING /� EXISTING SEPBC \\ SYSMA 6- — 2 1:46 30 2- 4- 3 1:46 — A, — 4 1:56 30 1 1/2- 4 1/2- 5 1:56 6- — I \ 2:06 30 SKY RANCH ESTA 4 1/4- LOT 7 QLOCK 5 2:06 — EX N 4 BBEDROCAI J SITE PLAN _ HyVSE 10-100, DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 8/13/2001 1 1:36 — 6- — 2 1:46 30 2- 4- 3 1:46 — 6- — 4 1:56 30 1 1/2- 4 1/2- 5 1:56 6- — 6 2:06 30 1 3/4- 4 1/4- 7 2:06 — 6- — 8 2:16 30 2 1/4- 3 3/4- 9 2:16 — 6- — 10 2:26 30 2 1/2- 3 1/2- 11 2:26 6- 12 1 2:36 30 1 2 1/2- 3 1/2- 19 PERCOLATION RATE 8.6 (MIN./INCH) PERC. HOLE DIA. 6- (INCHES) 20 TEST RUN BETWEEN 3.5 FT. AND 4.0 FT. COMMENTS: PERC HOLE WAS PRE—SOAKED FOR 4+ HOURS. PERC TEST WAS PERFORMED BY JOE MARCHETTI PERFORMED BY ALASKA WATER do WASTEWATER I, JEFFREY A. GARNESS, CERTIFY THAT THIS W S P RFORMEDI IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ZZ 01 DATE READING CLOCK 0 4 WATER LEVEL NET DROP � 1 X00 ALASKA WATER & WASTEWATER a ' t'• :S 2 1:54 CONSULTANTS. INC. 5 1 2' on 3 504 • so - s • FAX. (907)&M-3246 WUML m� _ g• — SOIL LOG — PERCOLATION TEST 2:24 30 LEGAL DESCRIPTION: SKY RANCH ESTATES /1; LOT 6, BLACK 5, OQ i e QQ4 •, C •••• amess•- 953 , .` PERFORMED FOR: RON BUSS DATE: 8/13/01 0 6 2:54 4 5 5/8' (feet) (f TEST HOLE 1 0t ofesslo 000 1 (PACE 2 OF 2) N SOIL CLASSIFICATIONS 2 u- oro' GW ____ ORG 3 GP ML GM CL 4 W GC OL Q °• • o o SW MH 5 Cl •'• SP CH SM OH SEE PAGE 1 OF 2 s Z O SC 7 DATE GROUNDWATER LLI e 2 OF 9 SvQPGE1 V) 10 Lij F- 11 O TIME (MINUTES) READING (INCHES) 12 Z O 13 Q U 14 U- 5 2:24 g• — N 15 U 16 J 17 O N 18 LLI W 19 PERCOLATION RATE 80 (MIN./INCH) PERC. HOLE DIA. 6' (INCHES) TEST RUN BETWEEN 7.5 FT. AND 8.0 FT. 20 COMMENTS: PERC—HOLE WAS PRE—SOAKED FOR 4+ HOURS PERFORMED BY ALASKA WATER do WASTEWATER I, JEFFREY A. GARNESS, CERTIFY THAT THIS W P FORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: o DATE READING CLOCK NET TIME WATER LEVEL NET DROP 8/21/01 1 1:24 — 6• — 2 1:54 30 5 1 2' 1/2� 3 1:54 _ g• — 4 2:24 30 5 5 8' 3/8� 6 2:54 30 5 5/8' 3/8� MUNICIPALITY OF ANCHORAGE DEPAR,..IENT OF HEALTH AND HUMAN SERVlCI Environmental Healtll Division 825 "L' Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Address tzqo/ If,",/),,, ,,; e'° D, Phone{s) Perlmt No No. of Bedrooms LEGAL DESCRIPTION TANKS ~ SEPTIC Manulaclu~er [] HOLDING TYPE OF SYSTEM ~/~TRENCI-I [~ BED [~ W. DRAIN [] OTHER ongmai glade ,~' FT /0 FT ~ FT ~5~ FT Gravel length Fl' ~otal absorphon 8¢ea ,.~ ~O SO FT ravel w~dlh FT FT WELLS ~ PRIVATE ~ OTHER (Identifv~ Classflicabon (A.B.C) ~otal Deplh JCased Io t FT Date Installed: DISTANCES  8EP'I'IC ABSORPTION TANK FIELD WELL WELL /oo /OO.5~ LOT LINE FOUNDATION [4 z4 AS-BUILT DIAGRAM (Show Iocahon of well, sephc system, property hnes, Iourldahon, driveway, water bodies, elc ) ]nstallo~ FT Scale: /t~T~~ Inspections Performed by: Dale: hltJnlC~pal and Stale gu~dehnes In ellecI on this date: ENGINEER'S SEAL 72-013 (3/85) r �f 1 1lJlV T C S: 1='FaL I:.�"Y C)F= F1NLhi0i=tFaGE=C ` DEPARTMENT OF" HEALTH AND ENVIRONMENTAL PRO TECTI N 025 L STREET, ANCHORAGE, AK 99501 264-4720 E3 [E TE= ;LWLii F= E=F<I-II 1T- fERMII No: 660050 DAZE ISSULD: 02/10/06 AIT'L.ICArII CC BUCI;. CONSTRUCI ION ADDRESS: 12901 RIDGEVIEW DR. ANCHORAGE, Al, 995.16 CON 1ACI PHONE: _345-1362 LEGAL DESCRIP: SUBDIVISION: SKY RANCH EST. SECTION: 22 TOWNSHIr: 12N LOT SIZE: 2100 (SQ.F"T. OR ACRES) NAX SEDROOMS: 1 Listed below are the options available to you system. Choose the - - - - - - - - - - option that bestt Fits your - - - - - - L11= 3 -r F-4E=r•ICI 1- DEPTH TO F'IF'E BOTTOM (FT.) 40� GFi(-iVEI_ DEPTH (FT.) 6., 0 . T01AL DEPTH (FT.) 10.0 , . GRAVEL_ WIDTH (FT'.) 2.5 GRAVEL LENGTH (FT.) 19.0 GRAVEL VOLUMC (CU. YDS. 11.5 TANK SIZE (GALS) 1,000.0 �a SO l l_ R' I NR ifs. FT. /BR)2 0 *# IAI I': MUST HAi OrC�OMF'ART 220 LEASTT IEfJTS LOT. b BLOCK: 5 RANGE: �'W in designing your septic site. L11= 3 W _ DF -{A I r.1 4.0 4.0 0.5 7;.5 4.5 7.5 13.0 5.0 25.0 24.0 12.1 17.8 1,000.0 M* 1,000.0 �* 220 1 certify that: 1. I am familiar with the requirements for on --site sewers and wells as set forth by the Municipality of Anchorage (MOA) and the State of Alast.a. 2. I will install the system in accordance with all MOA codes and regulations, and in compliance with the design criteria of this permit. I will adhere to all MOA and State of Alaska requirements for the set. back distances from any existing well, wastewater disposal system or public sewerage system on this or any adjacent or, nearby lot.. ;. I Understand that this permit is valid for a maximum of I bedrooms and any enlargement will require an additional permit. IF' A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES, THFN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST DE OBTAINED; (2) AS-BUILTS WILL. NOT E.- APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT: AND (;S) THE ELECTRICAL WORE: MUST BE DONE BY A LICENSED ELECTRICIAN. SIGNED aaE DATE: c� ArrLICANT: CC E;Llrl( CONSTRUCTION ISSUED L'Y DATE: __g__ ALASKA Inc. IlUlRorlm nTAL COFITROL S RUIC S, ~n§in¢¢rJn§ $ ~:nubonmcnl~l $1udics February 17, 1986 Muncipality of Anchorage Department of Health & Human Services 825 "L" Street Anchorage, Alaska 99502-0650 Attn: Steve Morris Subject: Lot 6, Block 5, Sky Ranch Estates Dear Steve: The owners of the subject lot are proposing a one bedroom addition to their existing residence built in approximately 1981. A percolation test was performed (data attached) and septic site plan prepared. It was discovered that the MOA files do not have an as-built for the existing septic system; only a septic permit was found. The builder is searching his files for a copy of the as-built. If it is not found, AECS plans to verify the existing system when the addition is installed. The builder plans to upgrade the septic tank by placing a 500 gallon, 1 compartment tank in front of the existing 1000 gallon tank. If you have questions, please call. Sincerely, ~Denn i--~RoF--~' Field Engineer Approved By: PhD, P.E. 1200 UJesl 33rd Avenue, $uii¢ [~, Anchorage. Alaska 99503,(907} 561-5040 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: L~'' ~,~,-' LEGAL DESCRIPTION: 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DATE PERFORMED: -~'o¢ /~,¢,4~Township, Range, Section: ./' SLOPE COMMENTS WAS GROUND WATER (ENG~L~R'S SEAU PLAN/ ' ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) Reading Date Gross Net Depth to Net Time Time Water Drop S IF YES, AT WHAT ~ DEPTH? . p v E Depth to W~ter Alter Moniloring? Oale: PERCOLATION RATE /¢ ~ (minules/mch) PERC HOLE DIAMETER TEST RUN BETWEEN ¢-~' FT AND /_?~, t0/ CERTIFY THAT THIS TEST WAS PERFORMED IN NAME MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECI'ION ENVIRONMENTAl_ ENGINEERING DIVIglON 825 L Str0et- Anchorage, Alaska 99501 Telephone 264..4720 ON-SITE SEWAGE DISPOSAL SYS"FEM AND/OR WELL INSPECTION REPORT PNONE I [~NEW 3/*9-6965 [] UPgrADE D & B GENE~A~, ~NC,/C,C. BUCK CONSTRUCTION MAILING~TD~,ES~0x 10-1349, ANCHORAGE, A~ASKA 99511 LEGAL DESCRIPTION Lot 6 Block 5 Skyranch Estates NC. CE BEDROOMS3 LOCaTIO~teeple Chase DISTANCE TO: .[ !.0.5' Manufacturer Greet Li~_.(5:~sr~city in gollons iF HOMEMADE: DISTANCE TO: I Well Manufacturer - Absorption area 6' Dwelling L~0' Material Inside length Width Stl PERMIT NO. Ha, nd~r£itt en No, of compartments 2 Liquid depth Dwelling PERMIT NO, Liquid capacity in gallons Well PERMIT NO, DISTANCE TO: 110 ' IMaterial Foundation 66' Nearest lot line 15' Total length of lines~Lj,, Trench width 36inches 2¥ Length of each line No. of lines 1 Distance between lines n/a Material beneath the Top of tile to finish grade Total effective absorption3a~. 96inches Length Width Depth PERMIT NO. Type of crib Crib diameter Crib depth Total effective absorption area Well Building foundation Nearest lot line DISTANCE TO: Class Depth Driller Distance to lot line PERMIT NO. DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE RATE.ALS PVC/CAST SOILTESTRATING 125 sq.ft./bdrm, INSTALLER D & B General, Inc, REMARKS ENVff, ;i ~,,.",, ', .C, ? ,h APPROVED DATE 10-18-81 LEGAL I~LS z2-013 (Rev. 3/78) Wall Log For........ .........`.-.'.... ......`................?.U.`...:.....f-e`............................................... Location..GU:..... �....... �C./1....s. .....5�r_r/�'C!JC ....r S—le7 : �. Date completed......... �.........T ................................................................................... Depthof well........`'.......................................................................................... Sizeof casing............................................................................................................ =00 Distanceto water.................................................................................................... Distance to water while pumping............`............................................at rate of....................`?:� o ........................... per hour. ....................................................................................... Driller ( DELTA DRILLING COMPANY SRA BOX 394 B ANCHORAGE. ALASKA 99507 Formation I from I to C ezy, -Ire 3 4 ��.Ly <.e y<< cy I t° o I iin ' I i ._ �>• Nps let) ....................................................................................... Driller ( DELTA DRILLING COMPANY SRA BOX 394 B ANCHORAGE. ALASKA 99507 Buck Construction 1577 C Street Anchorage, AK 99501 Permit 11 811098 January 4, 1982 Subject: L 6 B 5 Sky Ranch Estates SIHEU AN'CHOHA(A, ALASKA 99'_01 (90 /) 2G4 ,7111 A permit issued by this department for a well and/or sewer system has expired as of December 31, 1981. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal Ordinance. If you have drilled the well, a well log should be sent to this department to document the installation date. If an engineer inspected the installation of the on-site sewer system, please have them send us the as-builts for our files. If there are any further questions, please call this office at 264-4720. Sincerely, A 66 Les N. Buchholz R. . Program Manager Sewer and Water Program Enclosure: Copy of Permit LOCI:FIT I ON ;i!H~EEF'LE CHF[~SEi', E:,P. I VE TVF:'E OF: SO I L,. F:IE:!~IOf~'.F'T I ON '..::?~.'L::;]-EM I iii',: TP. ENCH '1:'HE LJF[i'.,IGTH r:, I i'"IEH';: 'S ] t'.,! 'S. S THE L. EI'.,IC;TH ,:: I .t-,! F:'EET ) C F' THE: .... I:;'E'H '" H C)[R [:,F~'.F:I I NF:' I !FI....E:,. TF.IL-': [:,E:]F:']"H I'i'F' I:::! 'IZF.:E!'.,tC:H OFR F'I't'~. 't)S ;~!fl,E [::,~:~.:,'l"i:~i'.,l~:~,~ii: E.'-E'/"HE[~]",I THE:: ':::_F?FF:IC':E OF'": THE I.. I::, THE ,:,F' cb,pr ::,. THERE Ii:.; NO :i?,ET HI[:,TH F'OF':: 'T'P.[~i'.,tL':Hi!~:~. ' "~' 'T'Ht:].: GF:FI',,,'EL [:fi:i.:.F:"T'H IS THE HtNIMUM [)EF"I"H OF' '.~iI:~'FI'v'EZ.. EiE'I"I.,IFi:EH THE i]iU"Ft::'f;:IL.L !::']~i:::'~iil FIN[:, THE F: ] T'TOM OF 'THE -::.:':: ] .::I'v'FIT T 3t'-,I ,' I N f':[-ZET ). F'EF:M :I: '1" FIF'F'L. I CFII'.,!T .-IFv:~ 'T'HE RE:r-: POI-,l'~; 1' E: 1: L I 'tV TO I NF'OF:'.M TH I S DEPFIF::THEN'T' i:::,Ul:~'. :[ NE:i T'HE ........ F.'F:.UF E:I'~. I .r Fff',ll) THE 1: h¢I~;'T'FiLJ...FIT _t: Eft'-, "i'.,I'::;F'I::'F:T' '[ r]l'.,ti:; OF' F~[",l"r' IJ[ .L.L.:., F:I[)..:rF:!CE:]'.,I]" TO TH 1 !4; .~ .......... ' !'.,ILIME~EF;'. C)F' ~,..: ._.,.I DENCE!:.:; 'I'HFFF THE HEL. L I,.IIL.L. SERVE. E:,EF'F~FR'I"ME'I'.,i"F H i L.L..E:E '::!IJE:.:I'EC'T "[' ') F:'I:~::O'.:!;ECU'F ! ON. M ): N I M U M [:, ! S"I" FI N C E B E 1" H E E.". N I:::1 H E L L. !:::I N [::, Ft N "r' O I":!'-"S I T E ~; E H F:I G E: [.'." L[..'5 P O :5 Ft L. S "r' :5 T E M :[ 'ii; 21.Ii:.'~O t::'~:'F'T FOF: !::1 I::'P'I:V:::ITL:: 14[FLL. OR ::LDO TO :.:'.':!~l~i~l Ftti,'~::F.':T I::'F::OM F:! PI...I!~!',L.I(.": HELL. I F:'r"d'.,l 'THF_'. "' ~.F'""t:. OF I::'l.J~:!_ )' {.': HEL. I .... ,t ~L i',! ~ !'.,I i HLIH [:, ! F::;")"FIt'.,IC:E F'.ROf',I I:::I F'P. ): VFI','I'E j .,. Ei',iL I?t '['O'~ ~::1 i~'F'?':[ ','F!'T'E 'SEH[~:P. I_ ]: I'.,IE :1: S 2!5 F:Ei:F::T' FIiqE:, "' ...... Mil F' I~.:.'i?. t": TO I::I '::OMHIJN :f: '[ '.~ SI:£HEF~: _ :t' t'.,lE: 1 ::, ,' ,~: NF:':I_I.. L.OGS RRE: P. EQI...I:[Fi:EE:, FIN[:, MU'.:i;T DE: F:E:TUF;tNEI:.':, TO '!"HE [::,EPF:ff~:"H"IEN'T' H:!:TH:,r.N :2:0 !:::'l':l'~"!i~; OF: THE I.,.IEL. L. COHPL. ET:[ON. OTI...II~{[.~i: i~?E(':)IJ Z F?.E:MEENT'-'~; I"11::1':.' F:IF'F'L.'~". ::*:!;PE:C I F I CFIT :[ ON:E; FIN[) C:ON:i~;'I-Fi:LICT I ON E:, :[ FIC~F'.I::M'!:i; !::IVI:::I I L..l::l[ifl_E TO I i'-,B'-!:UF:E: F'?.OPEI:~: ]: N!::TFIL. I_FIT I ON. :t: CE[TT' i F'"r' 'I"HFff :!.: :[ FIM F'FIH]:L. IFIF: HITFt THE Fi:EQt...IIFRE.'HENT:.::; FOR F'OF:'I'H !!i',V T'HE HLIN :1: C: Z F'F:IL. Z TV OF' FINC:HOI:~:FIGE. ;.:,.::: I f.,.I I L.L. I I",ISTFII_L THE :~ii;'~"..'.:.;"l"E:l'"! ]: I",I FICC::OF"'.:I:::'F!NCE I'.! I TH THE: COl)liES. 2:: I UNDEF::i.:.r;TFIt",!i) THFtT THE O!'.,!-..'.'5!'TE SEHEI:R S"r'ST[ii:M I'"lF~"r' F:E:G!IJIFi:E IZNI...i:::~Fi:GEHENT It::' '!"HE I:~:[.:::!i;:[[:,ENE:E :!:S F~:EMO[:,E:L.E[::, 'FO I!'.,!C:L. IJE:,E MO[RE THFII'.,! S ! C~iI'.,IE [:, · .................................................................................................................................................... F!r:'F'L. i CFti'.,FF F_:',IJ([:I-( CO~'-,!:E;"?]::::I.J(:'.:T .T. O1'.,1 I S:51..IEL':, E?'r'. .................................................................................................................. [:'f:I'T'E: ...... Z _Z .............................. · .... ' 'tUNICIPALITY OF ANCHORAGE Department ~ Health and Environmenta~ .,rotection 825 L Street, Anchorage, AK. 99501 264-4720 * * * HANDWRITTEN PERMIT * * * Applicant: ' Mailing Address: Location: _~r~-~.~) C-~,_~ CA~. ~ Phone Number: · ~ ~ ~ ~ [ ~ - Legal Description: ~_0~ ~ ~~ ~~~: [~ ~ ['7 Type of Soil ~sorption System Is: Trench: ~ Drainfield: Seepage Bed: Holding Tank: Maximum N~ber of Bedrooms: ~ Soil Rating (sq, ft/br) The Required Size of the Soil ~sorption System Is: DEPTH /.~ LENGTH .~ GRAVEL DEPTH ~ WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minim~ depth of gravel between the outfall pipe and the bottom of the excavation(in feet). /~ ~ * * : Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED * * * Backfilling of any system without final inspection and approval by thls departmeni w111 be subject to prosecution. Minimum distance between a wet1 and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minim~ distance from a private well to a private sewer line is 25 feet and to a co.unity sewer line is 75 feet. Well logs are required and must be returned to this department wlthin 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 31, i 9 8 1 * * * I certify that: (1) I ~ f~iliar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may r~uire enlargement if ncZu e mo e et Te ooms. S~ne~: Issued by SWP/024(1/81) ~4U~'! J . i, AL [ 'fY OF AN,.A¥IRAg~ Performed For Le~al nescrln~ton: This ~orm Renorts Soils Loe -~ i~ - i ~ !~ ~._~ ' '~ ' 2204 Cleveland Anchorage, Aiaska 99503 Monte AchesoR Enterorises _Oate Performed 4-12-78 Yes .,percolation %e~t .neath Feet Sot1 Characteristics Light Brown Gravelly Sand Gravelly Sand 10'-- Brown Sandy Silt 16. 18-- Bottom of Test Hole Was Ground Water Encountered? No_ ~/00~ I~ Yes, At what De.nth? Read,hq Date Gross Time Net Time Depth to HZ0 Net Drop Per&~o~la it ~ titnute :":'Prnposed Installatt.bn': Seenaae Pit Drain Field ,__ Oeoth of Inlet De,~ BOtt'om Of Pit O~ Trenc'h~ CDuH£NT$: 125 Sqr Ft.. drainage area requtrE_~ Der be__d, tloom from minus - 4' to lz'_._ _ _ ~ '- Test Per ......... . _ -- - - L'7im~- £1me '1 Date Date Date Inspector Inspector ! Inspector Conditional Approval Comments ~"'L/ ~ Dste Sewer Installed Permit No. Septic Tank Size /0 -q/ Holding Tank Size Soils Ratln~ Well To Absorption Area ~ · Well Log Received -- Well to Tank ~o ~ APPLICANT FILLS OUT LOWER HALF ONLY Property Owner ~ ~ ~VO ~ ~'~ r~'c~/ Phone -- Mailing Address ~ /~ ~ ~ ~1{/~, ~, ~ ~ ~ , Lending Institution ~ g ~ ~ ~ ~ L Phone -- Realty Co. & Agent ~¢/¢ ~/' /~/~/Y~v'~ ~/'~' ~~2~/~ ~ Phone -- Street Location ~ ~A [ '~¢ Type~ Residence OSingle Family ~ Multiple Family No. of Bedrooms ~ Other Wat~upply O'lndividual A~ACH WELL LOG. A well Icg is required for all wells drilled since June ~ Community 1975. For wells drilled prior to that date, give well depth (attach Icg if B Public Utility ~_.available.) Sew~ Disposal ' /¢ ~ J ~lndividual Year Individual Installed: M Public Utility When Connected to Public Utility:. E~ Holding Tank NOTE: THE INSPECTION EEE ~UST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. April E, 1962 Buck Construction SRA 1698 J Anchorage, AK 99507 Subject: Lot 6 Block 5 Skyranch Estates Approval for the individual sewer and water facilities cannot be granted until the following items have been completed: i/`egA well log submitted to this office for our files and review. ' Exposed electrical wires to the well head are in violation of the Municipality of Anchorage codes and oust be encased in conduit. c-O"The water analysis report needs to be submitted to this office from the Chen Lab, 5633 B Street, for our review. ' The depression over the sewer system will need to be filled so that surface water drains away from the sewer system. Please notify this department for a reinspection when the noted discrepancies have been corrected. if there are any further questions, please call this office at 264-4720. Sincerely, Robert C. Pratt Associate Environmental Specialist RP73/p/En n, ckqqL M x h r 41 R titiQ t4 ... �'6ri►< •�. Ppr3 a' � t 1 N a t,ti ~ n n in I• 06 ilk, -•• Lha ,}• QCtAPo eA or i�ll Q' • �. K W SSI QV •• 04 04 X004 titiV� I co I I -•r o� s ( � � 13SdHj 37d331S �`^^ -Aw Z Z I< Qit CO OV M r h r 41 R titiQ Q � tii ai ~ n n I• .6c Oih f� -Aw Z Z I< Qit CO OV v M r h r 41 R titiQ Q / ~ n 'M Oih f� QV •• v r 0 r Q Municipality of Anchorage , • Development Services Department Building Safety Division Onsite Water & Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage. AK 99519-6650 www.d.andxxage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING �t Parcel I.D. 015-301-32 HAA# 44 0 / D 'S/ �/ 1. GENERAL INFORMATION Expiration Date: / ?' A %— O / Complete legal description SKY RANCH ESTATES S1: LOT 6. BLOCK 5 ® Individual On-site 0 Location (site address or directions) 11971 STEEPLE CHASE CIRCLE Current Property owner(s) RON BLISS Day phone 351-4511 Mailing address Lending agency Mailing address Real Estate Agent Mailing address 16644 VIRGO AVE. ANCHORAGE, AK 99516 Day phone BOB BAER WITH TOTEM REALTY Day phone 724 E. 15TH AVE. ANCHORAGE, AK 99501 272-0571 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined In the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system Is(are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the Information obtained from the Municipality ofAnchorage files and from my Investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations In effect at the time oflnstallation. Name of Finn ALASKA WATER do WASTEWATER CONSULTANTS, INC. Phone Address 6901 DEBARR ROAD. SUITE 213 * ANCHORAGE. AY, 99504 Engineer's Printed Name JEFFREY A. GARNESS. P.E. Engineer's Comments: In conducting this evaluation, AWWC, Ina attempted to pmvfde a thorough, consdenficus engineering analysis of the system In accordance with ADEC and MOA DSD Guldelines d Regulations. The reported results descrfbed the performance ofthe system under the conditions encountered at the time of the tes4 and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local softs condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. AWWC, Inc. can themthm not provide any warranty crfuture estimate of how long the system wftl continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report Is for the sole benefit of the owner fisted above. Any rellance upon or use of this report by any otherperson orpartyIs not authodzed, nor will it confer any legal dght whatsoever. 5. DSD SIGNATURE Approved for L4 bedrooms. Disapproved. 337-6179 Date , vl Conditional approval for bedrooms, with the flowing stipulations: •' . ON-SITE ,990 WATERAND WASTEWATER PROGRAM NOTE: The attached septic system Maintenance Agreement shall be signed by the new owner at transfer of title and returned to this office. Attachments: HAA Checklist x Septic System Advisory _ Well Flow Advisory Manitenance Agreements Supplemental Engineer's Reort Other x By: a��� / Original Certificate Date:_ Cl -a-7-0/ trw. woo) Municipality of Anchorage • Development Services Department O"b W�ate�ra W"**V PMgMm 4700 $outh Sng8w St. P.O. Sant 198850 Anchorage, AK 99519.8850 www.c anehorage.ak us (907) 943-7904 HEALTH AUTHORITY APPROVAL CHECKLIST mal Description: SKY RANCH EST. ft, LOT 8, BLOCK 5 Parcel ID: 015-301-32 A. WELL DATA WON type PRIME If A. 8, or C provide PWSIDI/ N/A Date completed 10/15/81 Sanitary seal (Y/N).)[a Total depth2� R Cased to !9`+ fL FROM WELL LOG Data of we 10/15/81 Staticwaterlevei 200 IL Well production 8 9.p.m. WATER SAMPLE RESULTS: Well Lap (YM) YES Wires properly protected (Y/N) YES Casing height (above ground) 120+ In. AT INSPECTION 7/25/2001 209 fL 4.9 O.P.M. Colftm 0 cotonles/100 mi. Nitrate 0.5 mgJL. Other baclaAa 0 cl0lonies/100 ml. Date of sample: 9/18/2001 Collected by: AWWC. INC. 8. SEPTIClHOLDINGTANK DATA Tank Type/Materlal STEEL Date Installed 9/21/2001 Tank size 1500 pal. Number of Compartments 2 Cleanouts (YIN) YES Foundation cleanout (YIM YES Depression over tank (Y/N) NO High water alarm (YIN) YES .. Date of pumping NEW Pumper C. ABSORPTION FIELD DATA Datainstalled 9/20/2001 Sop ratlng .pA R'/bdnn) 2_0 System type ISF Lente 60 ft. Width 5 R Gravel below pipe 0.28 fL Total depth •at+ — R Etc absorption area, 300 R'Monitoring tube YES Depreaslon over field NO Date of adequacy test NEW Results (PesalFall) — For 4 bedrooms Fluid depth in absorption field before test_ In. Water added gal- _in. Elapsed Time: _ min. Final find Absorption rate "—g.pd. 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed 9/21/2001 Site In gallons 1500 Manhole/Axess (Y/N) YES 'Pump on' level at TIMERin. 'Pump dr level atnME n. High water alarm level at i in. Datum BOTTOM OF TANK Cycles tested NEW Meets alarm S circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tanknlft station on lot 100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer /septic service Me 251+ On adjacent lots 100'+ On edjacent ins 100'+ Public sewer manhole/deanout N/A Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundatlon 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service tine 10L+ Surface water 100'+ Wells on adjacent kns 100,+ rWArVER WR010070 SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property tine •5'+ Building foundation t 0'+ Wer mein N/A Water service Ione 10'+ Surface water 100'+ Driveway, parkingNehide storage 10'+ Curtain drain NONE KNOWN Wells on adjacent ins 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I car* Met t have determined through field 6rspectlons and review of Murddpat records that the above systems are in confonnarm wtlh MOA HAA guldetlnes In effect on this date. Engineer's Printed Name JEFFREY A GARNESS Data 41 IX -7 /01 HAA Fee S �. 00 Date of Payment Q a7 Receipt Number Otm.12MM Walver Fee S Date of Payment Recelpt Number 9/4/2001 Municipality of Anchorage George P. 11'uerch,May0r Department or Public Works Bn ldirlg S.tfcty Division P.O. Bos 196650 • 4700 S. Bragaty Street Anchorage, Alaska 99519-6650 • (907) 343-8301 ]t ttp://nit-Nv.cl.anchomgc.ak.tis Jeffrey A. Garrmess, P.E. Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Rd. Suite 2B Anchorage, AK 99504 Subject: Waiver Request for Sky Ranch Estates #1 Block 5 Lot 6 Waiver Request #WR010070 Parcel ID #015-301-32 Permit #015-301-32 Dear Jeffrey A. Gamess: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to property line has been approved. The approved separation distance is 0.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, Dantel J. Roth Civil Engineer On -Site Water & Wastewater Program WR#: WR010070 Date Received: 08122101 Applicant: Ron Bit$$ Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragsw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 Waiver Review Worksheet PID#: 015401-32 HAM Waiver Requested: 0 feet from lot line to absorotion Held Criteria: �7 A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Waiver is Granted: mac_ Permit#: Points: Total: Waiver is not Granted. List Conditions or Reasons for above: SEE E.UA•/NEED #S 1-E1lElP Di- Sksr/tfcN7/0N DATFD 8 — /6 -O/ AMhe'K,00 Date: 1648-01 By : P4AI Name of Reviewer Rec#: $Q¢,>} Amount: $718.00 Date Paid: 8!2212001