HomeMy WebLinkAboutNORTH WOODS BLK 2 LT 1Northwoods Block Lot 1 #051-741-18 Inspection Report Municipality of Anchorage Community Development Department Page 1 of 3 On-Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP151127 PID Number: 051-741-18 ❑ New ❑✓ Upgrade Name: Darrell R Lori Saylor ABSORPTION FIELD ❑✓ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 22928 Northwoods Drive Chugiak, AK 99567 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 830-0884 4 .6GPD/SF 9.5 Ft, LEGAL DESCRIPTION Depth to pipe invert from original grade 3.5 Ft. Gravel depth beneath pipe 6.0FL Subdivision Block Lot North Woods 2 1 Fill added above original grade 0-1 Ft Gravel length 90 Ft Township Range Section Gravel width 3Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist, between trenches From Tank Field Tank Line 1,080 Fiz One Ft. Well NA NA NA NA NA TANK ❑ Septic O S.T.E.P. ❑ Holding ❑ Other Manufacturer Existing Capacity I Gal. Surface Water >100' >100' >100' >100' Material Number of compartments Lot Line >5' 1'** N/A N/A NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. RemarksExisting STEP Tank Verified Suitable for Pump on level at in. Pump off level at in. High water alarm at in. Continued Use. Existing Trench Remains Available for Future Use. Pump make and model Electrical Inspections performed by **See Lot Line Waiver. Installer PIPE MATERIAL Housetotank D3034 Tankto D3034 drainrield Red Dog Excavating Drainfield F810 CO/MT D3034 Inspector MEA BENCH MARK (Assumed elevation) 100.Oft Inspection- dates: 1' 5/16/15 20 5/18/15 Location and description 3" 5/22/15 4'" Rear Deck COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL +��� gi Stafiw ,1 •�';I Conditional Approval: Date Q 9THE� PP����V111 ... .... ... ... /.... ..... I...................... MICHAEL E. ANDERSON :0 CE-4381 gam® II,t���sws Approved (�t/• ��g"� Date ����• Inspection Report o M NOR7-�IVV 3 i KLAOK _ o �S\ o O a I �� 0 m oma_. p c o N O0 \ O m S lg0p,00 m o ,W 129.08• 01 15, g UT Xl\ ` ` ` ` 1L1iy fAstmavr �1 O m o ® r = Xo U)mz O oo < m�O O O CL i O Dmf J 0 0 io- 0m2 F— O p A H N 000 H O Z n, �D ami �ti� a3(D�. D N O N 3 ,-p N, T � N A `z r. m A m O, O c Deo m o rC0 No = A m> rn T� CDm= O N N O W O /\ 0 (D Cn n D ® g `" N joo ii mmd w m < cD o IJ N I ur w o D Cf) rnym U N Q O -i s0 ° Z wm o w� x C ort o 3 � A \ O -0 po O o � F £ F o 1D UD�loaj!0 z N 00'00'00"W 179.08• ��i��i,,•• '•.S�'�j x o O O•• i? i A • ••.9j.�j a o 'D o ri o / /tiv �� 'y Z : O ARRRRSRR BAGIR68RIfF / 44 w Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 Elmore Road Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number:OSP151127 U ,5 Existing 1,500 Gallon STEP Tank Finished Grad. Geotextile Fabric Page 3 of 3 PID No. 051-741-18 M (O � U 101.5 n n i II II F 99.0 30 - 3/16" Diameter Holes @ 3' 92.0 —� — 85.0 Groundwater @ 88' 5115/04 Test Hole was placed in 2004 prior to the placement of an additional 2.5' of fill over the area. The original depth of the test hole was 14'. With the addition of the fill above existing ground The depth becomes 16.5'. PROFILE AS -BUILT No Scale " — 98.0 "PVc - �/— 92.0 Drainfield Rock F1 30 - 3/16" Diameter Holes @ 3' 92.0 —� — 85.0 Groundwater @ 88' 5115/04 Test Hole was placed in 2004 prior to the placement of an additional 2.5' of fill over the area. The original depth of the test hole was 14'. With the addition of the fill above existing ground The depth becomes 16.5'. PROFILE AS -BUILT No Scale " — 98.0 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP151127 Tax Code Number: 05174118000 Work Type: Septic Upgrade Permit Effective Dates: May 15, 2015 to May 14, 2016 Design Engineer: ANDERSON ENGINEERING Subdivision: NORTH WOODS Site Legal Address: NORTH WOODS BLK 2 LT 1 G:1559 Owner/Address: SAYLOR DARRELL W & LORI A 22928 NORTHWOODS DR CHUGIAK AK 995670000 Site Mailing Address: 22928 NORTHWOODS DR, Chugiak This permit is for the construction of: Y Disposal Field N Septic Tank N Holding Tank N Privy All construction must be in accordance with: Lot Size in Sq Ft: 27714 Total Bedrooms: 4 N Private Well N Water Storage 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: PRIOR TO CONSTRUCTION: Any portion of the property line, utility easement, and water service line within 20 feet of the proposed drainfield shall be flagged by a licensed surveyor prior to construction. Received B Issued By: Mu r of Anchorage Development Services Division On -Site Water and Wastewater Program Ment NOepartme�Til- **** VARIANCE/WAIVER REVIEW **** Waiver#: OSVIS1039 COSA#: Permit#:OSPISI127 PID#: 051-74148 Legal Description: Northwoods: Block 2. Lot 1 Engineer: Anderson Engineering Applicant: Darrell & Lori Savior` Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the absorption field has been approved. The approved separation distance is 6 feet. This waiver approval applies to the proposed and existing absorption fields only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or r another approval from this departri�extt , Q The affected adjacent propertyowniO ,hive been given a T day notice regarding this waiver.. Notarized letter(s) of non -objection have been received from the owner(s) of the affected ad' Jacent property. Adjacent properties are not affected by this waiver. Waiveria Granted: X Waiver is not Granted: Date: A— Approved by: ame of Reviewer >I MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-741-18 Property owner(s) Darrell & Lori Saylor Mailing address 22T Northwoods Drive Chugiak, AK 99567 Site address 22928 Northwoods Drive Chugiak, AK 99567 Day phone 830-0884 Legal description (Sub'd., Block & Lot) North Woods, Block 2, Lot 1 Legal description (Township, Range & Section) Lot Size 27,714 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (M all that apply) Absorption Field E] Initial Single Family (SF) El (w/wo ADU) Septic Tank ❑ Upgrade Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Trench to Trench Distance: 7' I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. 'fL(� of property owner or Permit/Rush Fees: Date of Payment: _ Receipt Number: d Permit No. Qsr Permit App_9-1-12.doc U Waiver Fees'. Date of Payment: S /y 49 Sp q C7 -Receipt Number: —1 lT Id _;� Waiver No. 0Sj(5-/03q May 14, 2015 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, Block 2, Northwoods Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The existing absorption trench on the subject lot has failed and must be replaced prior to the issuance of a Certificate of On Site System Approval (COSA) for the lot. We are therefore requesting a permit be issued to construct a new absorption trench to accommodate the four-bedroom home on the lot. The existing 1,500 gallon STEP tank will be inspected and verified suitable for continued use. The attached Site Plan and backup documentation identify the location and configuration of the proposed absorption trench and the existing septic system and water service. The subdivision is served by a public water system. No conflicts exist between the proposed absorption trench and septic system and wells or septic systems on adjacent lots. A lot line waiver was issued with the original septic system permit for the lot allowing the new system to be within 1' of the lot line. The test holes placed on the lot in the area of the absorption trench and alternate site during the initial permitting indicate the presence of silty sand with some gravel. The percolation rate of the material was determined to be 12.6 to 20 minutes per inch. No groundwater was found during the placement of the test hole but registered at 11' below the surface during the monitoring period. An application rate of .6 gallons per day per square foot was used in the design of the absorption system. We are proposing to use the existing 1,500 -gallon STEP tank and a new 85' long by 3' wide by 6' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3.5' below the existing ground surface and the total depth will be 9.5' below ground. This depth is exactly the same as the existing trench and the bottom of the new trench will be at the same elevation as the existing trench. An additional 2' to 4' of fill was placed over the septic area during the construction of the existing absorption trench. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench. The new trench will be only 7' from the sidewall of the existing trench. A waiver request is Lot 1, Block 2, Northwoods Subdivision May 14, 2015 Page Two attached to allow the encroachment into the rregquuiireed�sseparratti n distance. The ground surface on the lot in thearea of the septic system is flat. The new trench will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the existing water services in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, E Michael E. Anderson, P.E. Attachments 49th•••°: E. ANDERSON CE -4381 May 14, 2015 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, Block 2, Northwoods Subdivision New Absorption Trench to Existing Trench Dear Onsite Services Engineer: Very fl!�,�ar a is avail ble on the subject lot to construct a new absorption system due to the.l�� the property. The alternate absorption trench site was approved with the original permit in 2004. The sidewall of the alternate trench was located 7' from the primary trench. The primary trench has now failed and must be replaced. The soil on the lot percolates between 12 and 20 minutes per inch. Little migration of the septic effluent is expected. We therefore recommend the new trench be placed at the location previously approved and 7' from the existing trench on the lot. Sincerely, 4 4 Michael E. Anderson, P.E. 49th••••• a MICHAEL E. ANDERSON No. CE -4781 . � < O � O r x<o om \ NOR 1 l 1, I A ' 0 \ \ VIV O N r Z �D D 0 2. cc S a o�=o� \RI�E <o, o D -co uns 'S'oo'oo••W O 29.08 r T % V coN ` 0 � O � To N� 15• �T�trry 0 I N1 \ ` EASEMENT x �� Z < O G_7T1 � a 0 H (�OD mm� m _- Ao S Y 2 o Q7 r 11 " N N O " r- 0 cn o £ C s m o = a Q7 —p y� N s < L 3 cn T � y 71 RZOo T qs!=R z �1 a Z x Z oN o 3o� _0 a m = Q o ,oZm uJ �� -.0 _ (f Z- _0 � M� x -i O D N IV 3 y! Q F % O g p ' C C� Wc� 3 ram Z- 0 ••�....•��ti _ N 00.00'00"w 1 9.08' a 0za it f ♦ i :.\ p : �] (,P`i ^ ; �NDBRPOR 8AGf8P8RlPC • •+Olt �1R�� ••• LOT 1, BLOCK 2, NORTHWOODS DESIGN FACTORS: Four Bedroom Home Pere. Rate: 20 Min./Inch Application Rate: VGPD/SF 4 Bedrooms X 150 GPD/.6 GPD/SF (Application 1,000 SF/12 SF/LF = 83.3 LF Trench Length SYSTEM REQUIREMENTS: DeepTrench System 1,500 Gallon STEP Tank - Existing 6' Drainfield Rock Rate) = 1,000 SF Absorption Area THEREFORE: Construct a 85' Long x 3' Wide x 6' Effective Depth Absorption Trench at the Location Shown. Flow Line Elevation in Trench to be 3.5' Below Original Ground Surface. Total Depth to be 9.5' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Maintain 100' Separation from Wells in the Area. 310" Natural Backfill Geotextile Fabric 6" O 1" Perforated PVC (Holes Down) 3/16" Diameter Holes 30 Holes @ 2.8' on Center 6'0" Drainfield Rock 3' TYPICAL DEEP TRENCH SECTION NOTE: (NO SCALE) Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams: VeTech Engineering Technical `. P.O. Box 873141 Wasilla, Alaska 99687-3141 Phone: 907-357-6304 Fax: 907-357-6305 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION- I OT I BI OCK 2. NORTHWOODs _S/D PERFORMED FOR- LARRY McBAIN _- DATE: 3/31/2004 PROJECT No - M0414 PARCEL ID#: TECHNICIAN: T.L. KIMBROUGH f `49ILI .•e •'oe•owe ... • ........ s®o MCIIAEL !. ANDERSON •,ate' , CE -4381 DEPTH TEST HOLE # 1 Type of Test: ® Percolation ❑ Visual (feet) 1 READING 2 ... 3 s� 4 TEST HOLE PRESOAKED PRIOR TO TESTING: 5 1 11:00 6 7.0" 1 1 OB / OG PERC ZONE BROWNISH - GRAY DAMP SILTY -SANDS W/GRAVELS ORGANICS SOME COBBLES TO 10" SLOPE SITE PLAN F-' LU LU w U) w } F- OTH2 OTHI e SEE FUTURE ASBUILT WAS GROUND WATER ENCOUNTERED? NO IF YES Q WHAT DEPTH? 2% DEPTH OF WATEIZ�AFTER MONITOR) NG: DATE OF MONITORING: 5/15/2004 E ��% f� i low DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) WATERF (INCHES) INET DROP (INCHES) 3/31/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 11:00 7.0" CHARGE 2 11:30 30 4.5" 2.5" 3 11:30 8.0" RECHARGE 4 12:00 30 5.625" 2.375" 5 12:00 8.0" RECHARGE 6 12:30 30 5.625" 2.375" PERCOLATION RATE: 12.6(MIN/INCH) PERC. HOLE DIA. -(INCHES) TEST RUN BETWEEN:: 55 FT. and 6.5 FT. COMMENTS: NO IMPERMEABLES ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR To TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE-- VeTech Engineering P.O. Box 873141 Wasillc Phone: 907-357-6304 Technical Servi( Alaska 99687-3141 Fax: 907-357-6305 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION- 1 OT BLOCK 2 NORTHWOODS SID PERFORMED FOR* LARRY McBAIN DATE: 3/31/2004 PROJECT No • M0414 PARCEL ID# TECHNICIAN: T.L. KIMBROUGH A . 49T–H e a+m : WCHAEL E. ANDERSON,,-' CE -4381 <°�,® 6q�tfQFO,�' �1r/ p°� @®a_pROFESSV-4tp DEPTH TEST HOLE # 2 Type of Test: ® Percolation (feet) 8 9 10 ..r.' •y r, 12-- 14—' 2 14 . I I OB / OG PERC ZONE BROWNISH - GRAY DAMP SILTY -SANDS W/GRAVELS ORGANICS SOME COBBLES TO 10" SLOPE SITE PLAN H— z Lu g Lu a Lu r J OTH2 OTHI 0 SEE FUTURE ASBUILT WAS GROUND WATER ENCOUNTERED? NO SS IF YES Q WHAT DEPTH? L 2% DEPTH OF WATER AFTER MONITORING: 3 O DATE OF MONITORING: 5/15/2004 Ct DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH OF WATER (INCHES) NET DROP (INCHES) 3/31/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 11:15 8.5" CHARGE 2 11:45 30 6.875" 1.625" 3 11:45 8.0" RECHARGE 4 12:15 30 6.5" 1.5" 5 12:15 1 8.0" IRECHARGE 6 1 12:45 30 1 6.5" 1 1.5" PERCOLATION RATE:00.004INANCH) PERC. HOLE DIA. 6_ffINCHES) TEST RUN BETWEEN:: 5_5 FT. and 6.5 FT. COMMENTS: NO IMPERMEABLES ENCOUNTERED TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: Municipality of Anchorage Page 1 of 3 Development Services Department Onsite Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 Tlnhw.d.ondlorage.sk.us (907) 343.7904 ONSITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO40185 PID Number. 051-741= / $ Mai, Ascend Construction Wastewater System: New Adanea: P.O. Box 231169 Anch., AK 99523 ABSORPTION FIELD 223.3725 our Deep Trench LEGAL DESCRIPTION Sd Rema. TaW DORM ham a" Grade. 7 .6 GPINVe FI. 111 c La lsubd t Depm m PRO hen agrW Wad- G,v degm harm pap 2 1 Northwoods . ` % 1 FI. FA added rd.a cng r Vada. 6 Ft Qx LffvP To -wap'. Ranee. sdr - ✓ 24 FI. 87 Ft. Well: Community Water System esel rrdln. 3 14 n of 1 D.M U.I..en Ines. Ft. - FL clnadrnan lPrN«e. A. a. Q. Total Deptl Grad m. a«tleapa wow PRO MIM.el. FI. Ft 1,044 Fe ASTM 3034 PVC Dnlw: Date Dntbd: stead Welt Lent: Ft Sanders 3 Sanders 6114-1612004 Yem. PWVsatG"V 1.0 MmwGraem TANK GPM Fl. FI SEPARATION DISTANCES STEP To From Septic Tank Absorption Field Litt Station Holding Tank lubliaIvrnate sewer Line " Anchorage Tank m 1,500 WON >100' >100' >100' NIA >25'Steel Two (2) aMrwa. w«« >100' >100' >100, WA LIFT STATION Latuo >5' >10, >10, WA 250 G« Anchorage TanWOrenco Faum•on >5' >10' >5' WA �W 42« n 42 to I High 44 a«. m. DMlen Dra+l >20' >20' >20' PW V M" a Madel Orenco EMchKat tnepeanne pwk med by Certified Electrician R° ha BENCH MARK Finished Floor. A wmd ENv«wn: 100.0 Ft Engineer's Stamp ��p�salgss .� • Inspections performed by: MEA Dates: 1" 6114/04 wo 49th • Zm 6I16I04 r r _. t • , -�A}y MICHAEL E. ANDERSON/ Department of Health and Human Seryices approval •. s+ No. CE -4381 F$" Reviewed and approved by: 4 Date: a 9 - Date: ,# �" P��:'e haa�r;5`�a'..• (ne.. favor N in :- iD in % Cl) m b r I: fV N 0 M A n iD •j6't'•.t i : Q O .D ISS "•. Q r A •••"_ �.�•�. N o N •••��� �••• MZ Uvi51 wi. Il O n. m OS 00'0025' E 179.08' m C) V. n 0) �d Z�C o if ZIn �l U�LU � C coa I L N 0)(L ` O gF N m o o a< 0 N w S m o � O oOQ o J N �� a Z a I c W 0)_y N OJ o>o ) O Y W i I II I f (n m U) pW I i a�- a sD I m 8 S j S Q Q G I I J W � N y I / ^I N m O 3ia Z L i i m VJ (_ wrn$ D in ® b Q in 3 N O U) in � N O S o Olros3 3 3 A �nunsr g 620q SOoo N 4114 a3 \`� 1&pN v �, O o J m F— O J Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number. SWO40185 TBM Page 3 of 3 PID No. 051-741-32 101.24' Geotextlle Fabrlc 100.87' PROFILE AS -BUILT Scole: 1" a 20' 1- PVC 3/16'Holes 2 3' Spacing Dralnfleld Rock PROFILE AS -BUILT Scole: 1" a 20' Feb 25 05 03:49p ■ Willodell Enterprises Inc 349-9164 WILLORELL L EntzalrprSO Ir��•. Phone(907)561-6064 Pax(907)349-9164 Cell Phone (907) 2443754 Emailteveo r1.ak.net www. w i l l od e l l en t err ris es. a om February 25, 2005 To whom it may concern, p.1 P. O. Box 230972 Please know that Lot 1 Block 2 Northwood Phase 2 Septic System is wired to Local and National Electrical Code, per 2005 NEC Code Book. General and Electrical Contractor #28550 Permit Number: SW040185 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial (.0IILA (oy-401 1011'-3 4 C O r%4 Mto Date Issued: Jun 14, 2004 Expiration Date: Jun 14, 2005 Parcel ID: 051-741• 19 Legal Description: NORTH WOODS : 7 3LK 2 LT 1 " Design Engineer. 0014 Anderson Engineering Site Address: 022225 WHISPERING BIRCH DR Owner Name: Ascend Construction Lot Size: 27938 SO. FT. Owner Address: P.O. Box 231169 Total Bedrooms: 4 Permit Bedrooms: 4 Anchorage , AK 99523 - This permit Is for the construction of: ❑� Disposal Field E Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3• The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, seated, and heated to prevent freezing. Received By. Issued By. Date: Date: G i Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 995195650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 4 1 — 3 Z Permit Number SW Property owner(s) Ascend Construction Day phone 223.3725 Mailing address (1) P.O. Box 231169 Anchorage, AK 99523 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 1. Block 2. North Woods Subdivision No. 2 Legal description (Section, Township & Range) Lot Size 27,TM SF Acrese) THIS APPLICATION IS FOR: Number of Bedrooms Four (4) Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Waiver Fees: Date of Payment 1 0Ci Date of Payment Receipt Number. Receipt Number. (Rev. 12/00) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX June 1, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, Block 2, North Woods Subdivision No. 2 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 1, Block 2, North Woods Subdivision No. 2 intends to construct a four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is currently served by a community water system. The Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The water service to this lot is also shown. Existing spot elevations and the current drainage pattern are also identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Two test holes were recently placed on the lot, which indicated silty sand with gravel in the area of the absorption trench. The accepting soils were tested and found to have a percolation rate of 12 to 20 minutes per inch. No groundwater was found during excavation but was noted at 11' below the surface during the monitoring period. Our design includes the placement of a new 1,250 -gallon septic tank along with an 85' long by 3' wide by 6' effective depth absorption trench to collect and treat the sewage generated in the house. The bottom of the trench will be 7' below the surface to provide the required separation from the bedrock. The distribution pipe will be 1' below the surface. A minimum of 3' of cover will be placed atop the trenches and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at shallow grades from southwest to northeast to the midpoint of the lot and then drops off sharply as shown on the Site Plan. The absorption trench will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system Lot 1, Block 2, North Woods Subdivision No. 2 June 1, 2004 Page Two will be constructed 1 00'from all surface water. It will also be constructed a minimum of 10' from any water service in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, w Ea"' , Michael E. Anderson, P.E. Attachments th MICHAEL E. ANDERSON 6. No CE -Asst -, 1�a^ 2 a, s P 1 25 26 20 It 1 21 ffi Q R jog fie, �"3 22 to16 ' AIr1vFa"G � s � as<o s a C1 aal p 2 g a sad V 23 a�, 117 s.•' PSE .'"."'.,, S h� `ter ,+M... :... •MCMIELE.IIIOER!"H •• AREA MAP -� No 4 SCALE 1" = 100' �*4 sslo LOT 1, BLOCK 2, NORTHWOODS SUBDIVISION NO.2 DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House Deep Trench System Perc. Rate: 20 Min./Inch 1,250 Gallon Septic Tank Application Rate: .6 GPD/SF 6' Drainfield Rock 4 Bedrooms X 150 GPD/.6 GPD/SF (Application Rate) = 1,000 SF Absorption Area 1,000 SF/12 SF/LF = 83.3 LF Trench Length THEREFORE: Construct an 85' Long x 3' Wide x 6' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 1' Below Original Ground Surface. Total Depth to be T Below Existing Ground. Maintain 10' Separation From Water Service on Lot. Provide T of Cover Over Trench and 4' Over Septic Tank or Provide 2" Insulation and 2' of Cover. Maintain 100' Separation Between Open Surface Water and Septic Tank and Absorption Trench. Natural 6' Backfil Geotextile Fabric 6^ 4" Perforated PVC (Holes Down) aii ;AL DEEP SCALE) Drainfield Rock NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. . Minimum 10' Separation From Water Service Line. VeTech n ical Service P.O. Box 873141 Wasilla, Alaska 99687-3141 Phone: 907-357-6304 Fax: 907-357-6305 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION OT L RI O K T. NORTHWOODS #2 SID PERFORMED FOR- LARRY McBAIN DATE: 3/31/2004 PROJECT No • MO414 PARCEL IDN- TECHNICIAN: T.L. KIMBROUGH DEPTH (F«q 1 .•. OB / OG 2 3 4 6 7 8 9 11 OF A4 %to , 4EL E ANDERSON•�� CE -4381 TEST HOLE # I Type of Test: ® Percolation ❑ Visual PERC ZONE BROWNISH - GRAY DAMP SILTY -SANDS W/GRAVELS ORGANICS SOME COBBLES TO 10' WAS GROUND WATER ENCOUNTERED? NO IF YES @ W HAT DEF n r DEPTH OF WATEL)ATE RMOMTORING 3' y(//URATE OF MONITORING: 5/15/2004 SITE PAN z LU w a w J OTH2 OTHI SFE FUTIRF ASnllll T 2% DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) WATERF (INCHES) I NET DROP (INCHES) 3/31/041 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 11:00 7.0' CHARGE 2 11:30 30 4.5' 2.5' 3 11:30 8.0' RECHARGE 4 12:00 30 5.625' 2.375' 5 12:00 1 8.0' RECHARGE 6 1 12:30 1 30 5.625' 1 2.375' PERCOLATION RATE I� 2_6 (MINANCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN --5.5 FT. and 6.5 FT. COMMENTS: NO IMPERMEABLES ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR To TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED N ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: VeTech Engineering P.O. Box 873141 Wasilla, Phone: 907-357-6304 Alaska 99687-3141 Fax: 907-357-6305 SOILS LOG - PERCOLATION TEST rvi LEGAL DESCRIPTION- I OT L BI OCK 2. NORTHWOODS #2 SID PERFORMED FOR- LARRY McBAIN DATE: 3/31/200/• PROJECT No - M0414 PARCEL IDJP TECHNICIAN: T.L. KIMBROUGH III 4918 f ;a MICHAEL E. ANDERSON '�•, CE .4381 •:moi; ✓ice •. A: m DErnl TEST HOLE # 2 j Type of Test: ® Percolation tf«n 10 i:: 4'•Y�, 12- 13- 14- 15- 16- 171 21314151617 18 19 SITE PAN H z w uj w a Lu r J OTH2 OTHI in SFF FUTLIRF ASRUII T WAS GROUND WATER ENCOUNTERED? NO IF YES Qr WHAT DEPnr? 2% DEPTH OF WATER AFTER MONITORING: 3• DATE OF MONITORING: 5/15/2004 DATE READING OB / OG NET TIME (MINUTES) WATER (INCHES) NET DROP I (INCHES) 3/31/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 2 1 11:15 8.5' CHARGE 3 2 4 "'�.:• 6.875' 1.625' 3 11:45 8.0' RECHARGE 6 -: PERC ZONE 30 6.5' 1.5' 7 BROWNISH - GRAY 12:15 c:'Sd DAMP SILTY -SANDS W/GRAVELS 8 '• `' ORGANICS SOME COBBLES TO 10' 6 12:45 30 9 ..,,`. 10 i:: 4'•Y�, 12- 13- 14- 15- 16- 171 21314151617 18 19 SITE PAN H z w uj w a Lu r J OTH2 OTHI in SFF FUTLIRF ASRUII T WAS GROUND WATER ENCOUNTERED? NO IF YES Qr WHAT DEPnr? 2% DEPTH OF WATER AFTER MONITORING: 3• DATE OF MONITORING: 5/15/2004 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) WATER (INCHES) NET DROP I (INCHES) 3/31/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 11:15 8.5' CHARGE 2 11:45 30 6.875' 1.625' 3 11:45 8.0' RECHARGE 4 12:15 30 6.5' 1.5' 5 12:15 8.0' RECHARGE 6 12:45 30 1 6.5' I.5' PERCOLATION RATE`(MIN/INCII) PERC. HOLE DIA. 6 (INCITES) TEST RUN BETWEEN:: 5_5 FT. and 6.5 FT. COMMENTS: NO IMPERMEABLES ENCOUNTERED TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 1, BLOCK 2, NORTHWOODS SUBDIVISION NO.2 GENERAL: The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 85' long X 3' wide X 6' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 1' below the existing ground surface. Total depth of the trench will be 7' below the existing ground surface. The new absorption trench must be placed a minimum of 10' from the water service on this and adjacent lots. A minimum of 100' must separate any surface water in the area and the septic tank and absorption trench. The trench must be a minimum of 10' from the lot line. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,250 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Lot 1, Block 2, Nonthwoods Subdivision No. 2 June 1, 2004 Page 2 of 3 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of ball depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' Wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: Septic tanks must be constructed by a municipally approved septic tank manufacturer. Lot 1, Block 2, Northwoods Subdivision No. 2 June 1, 2004 Page 3 of 3 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Jun -14. 2004 6:34AM 9075226779 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 88524 522-7773 522.6779 (F DATE: 6/14/2004 TO: Joe Goodall WITH: MoAJOnSite Water and Wastewater FROM: Mike Anderson SUBJECT: Lot 1, Block 2, North Woods Subdivision No. 2 Well and Septic Construction Permit No -6500 P. 1/1 The groundwater depths in the test holes completed for the septic system design for the subject lot were measured at 3' total depth or 11' below the surface as measured on May 15, 2004. The bottom of the absorption trench will be 6' below the surface to provide a minimum of 4' separation to groundwater. We have modified the design to include a 1500 -gallon STEP tank athe drop between the septic tank and the field Is not sufficient to provide gravity flow. as -built for the system will show the details of the pressure distribution system. Based on the above information we are hopeful the well and septic system permit can now be issued. Please let me know if you have additional questions. y678go v� R`/S`hli 6 2015 • � Municipality of Anchorage a ;� On -Site Water and Wastewater Program j (907) 343-7904 q R�d I /! I G 9 yn Certificate of On -Site Systems Approval Parcel l.D.051-741-18 Expiration Date: 1. GENERAL INFORMATION Complete legal description North Woods, Block 2, Lot 1 Location (site address) 22928 Northwoods Drive. Chugiak, AK 99567 Current Property owner(s) Darrell & Lori Saylor Day phone 830-0884 Mailing address 22928 Northwoods Drive Chugiak, AK 99567 Real Estate Agent Day phone 2. TYPE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Four 3. NUMBER OF BEDROOMS: 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual Q Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System . Public Sewer ❑ WaiverNariance request for: Received by: COSA to be released to the Date: I COSA Fee $ qZA -(Q6 Waiver Fee $ Date of Payment 5/aTlls Date of Payment Receipt Number Receipt Number COSA# (�.SClS(a� Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineers Printed Name Michael E. Anderson, P.E. Date 5/26/2015 APt OF A4 di 4918* 6. DSD SIGNATURE ® eI M "" System #1 Approved for bedroomsW °°' /.. . `, ?,r�M120 EL E. ANDERSON °. Q System #2 Approved for _ bedrooms �# SO. CE -4381 s . ®� Disapproved ` f P pr �p� 4��® ROFESSIO° ��► Conditional approval for bedrooms, with the following stipulatiofl�q®®ya®" By: Original Certificate Date: �' �✓� Thenici li of forage Development Services Division (DSD) issues certificates of On -Site Systems Approval (COSA) based only upon the representations given In paragraph 5 by an independent professional civil engineer registered In the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. - 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA blue sheet_[ f- L, c Nitrate Advisory Arsenic Advisory Other If more than 1 septic system is on the lot: COSA Checklist # _of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: Northwoods, Block 2, Lot 1 A. WELL DATA - Public Water System - No Well on Lot Well type If A, B, or C provide PWSID # Date completed Sanitary seal (Y/N)_ Total depth ft. Cased to ft. FROM WELL LOG Parcel ID: 051-741-18 Well Log (Y/N) Wires properly protected (YIN) Casing height (above ground) in. AT INSPECTION Date of test Static water level ft. Well production g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: Collected by: ft. g.p.m. B. SEPTICIHOLDING TANK DATA Tank Type/Material STEP/Steel Date installed 6/14-16104 Tank size 1,500 gal Number of Compartments 2 Cleanouts (YM) Y Y Foundation cleanout (Y/N) Date of pumping 12/2014 C. ABSORPTION FIELD DATA Depression over tank (Y/N) N High water alarm (Y/N) N Pumper One Stop Pumping Date installed 5116-18/15 Soil rating (g.p.d./ftp or fe/bdrm) .6 GPD/SF System type Deep Trench Length 90 ft. Width 3 ft. Gravel below pipe 6 ft. Total depth 9.5 ft. Eff. absorption area 1,080 fe Monitoring tube Y Depression over field N Date of adequacy test New Const. Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) N If yes, give date D. LIFT STATION Date installed 6/19-19/04 Size in gallons 1,500 Manhole/Access (Y/N) Y "Pump on" level al if in. "Pump off' level as _ in. High water alarm level at 44 in. Datum Bottom Of Tank Cycles tested 3 Meets alarm & circuit requirements? Y E. SEPARATION DISTANCES - Public Water System -No Well on Lot WELL ON LOT TO: NA Septic tank/liftstation on lot NA On adjacent lots Absorption field on lot NA On adjacent lots NA Public sewer main NA Public sewer manholelcleanout NA Sewer /septic service tine NA Holding tank NA Animal containment areas NA Manure/animal excrete storage areas NA SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >51 Water main >10' Water service line >10' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: 1** ' Absorption field >51 . Surface water >100' N/A Property line 1 Building foundation >10 Water main i Water Service line >10' Surface water >100' Driveway, parking/vehicle storage > None Noted >100' Curtain drain Wells on adjacent lots F. COMMENTS Property is served by AWWU Water System. **See Lot Line Waiver. G. ENGINEER'S CERTIFICATION I certify that t have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 5/9/2015 COSA brown sheet 10.10-12.doc MEN 10'. MICHAEL E. ANDERSON : i�; a % �.•• E_ 4381 :tea AW s Z& lv �0 FyFa •.. ���w +��°Aaa®Sw ��'• 5• x IT. Anchor Easement It It �15, utklt / Easement Is Shed X 19.21 EAST 10' x 5' DECK � 2a p1 56N t 00 0 a; LOT 1 BLOCK 2 w in JSeea Detail �Spetic Manhole CD ® CD 0 LEGEND z .o- ® SEPTIC PIPE 202,18' " WATER KEY m TEL PED A ELECT PED Detail o FD 3 1/4" MONUMENT 26,4' • FD RBR ® FD 6" SPIKE 14.0' O SET RBR 22.0' 3 y FrareDECK 20,0' ^=��P�E.OF A. 4s�r9hr, 16.0 House * : 9TH 24,5' .• .. ..... .. '•.Ant ony P. Boneta: `2' 10.5'r�'� ,' LS -10393 26,9' \ 15,5 ,4;a' a�6�af.l"�, 1lt �'EssloMn+-`' I hereby certify that I have surveyed the following described property: Lot 1, Block 2, North Woods Subdivision, Plat No. 79-195, Anchorage Recording District, and that no encroachments exist except as indicated hereon. This As -built will only show the easements that appear on the recorded subdivision Plat No. 79-195, Anchorage Recording District; under no circumstances should this data hereon be used for the construction or establishing of boundary or fence lines. a25 50 SCAB IN FEET Surveyed: May 20, 2015 North Woods Subdivision Lot 1 Block 2 As Depicted on: Plat No. 79-195 Anchorage Recording District GRID:NW1559 ASBUILT SURVEY 22928 Northwooas Drive Chuglak, Alaska 99567 APB Land Surveying 12204 East Prince of Peace Drive Eagle River, Alaska 99577 (907) 227-1361 Municipality of Anchorage Development Services Department Building Safety Division Onsite Water and Wastewater Program . 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-650 www.cd.anchorage.sk.us (907) 343-7904 AlC4A4ec. t- 4oeese, CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 51.741 HAA # DSW(6a4 Expiration Date: '2- - *?- 8 - O 6- 1. GENERAL INFORMATION A. Complete legal description Lot 1 Block 2 Northwoods Subdivision = . Location (site address or directions) 22225 Whispering Birch Drive q 5,; -A- Current Property owner(s) Ascend Construction Day phone 213.3725 Mailing address P.O. Box 231169 Anchorage AK 99523 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA wN be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four 4 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class A Well ® Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given In paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined In the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system Is(are) Safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522.7773 Address P.O. Box 240773 Anchorage. AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 2!21/05 5. DSD SIGNATURE Approved for _14L bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist X Septic System Advisory Well Flow Advisory ON-SITE i IAIACTCIA/ATCD PROGRAM Maintenance Agreements Supplemental Engineer's Report Other By: �,✓ �� 1 Original Certificate Date:— a. $ - 05 (a«.12M) Municipality of Anchorage ' Development Services Department Building Safety Division On Site Water & Wastewater Program : 4700 South Bragaw, SL P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.enchorage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST A. WELL DATA Well type _ If A, B, or C provide PWSID # 9 Date completed _ Sanitary seal (YIN) — Total depth ft. Cased to iL FROM WELL LOG Data of test Static water level ft. Well production g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mi. Nitrate mg.A. Date of sample: Collected by - B. SEPTICIHOLDING TANK DATA Tank size 1.300 gal. Foundatkm cleanout (YIN)X Date of pumping C. ABSORPTION FIELD DATA Number of Compartments I Depression over tank (Y/N) _N Well Log (YRJ) Wines property p (YM) Casing height (above ground) in. AT INSPECTION R Other bacteria Cleanouts (YIN) colonies/100 ml. High water alarm (YIN) Y Date installed UI8R004 Soil rating (g.p.d./fe or fle/bdrm) ,6 GPDISF System type DeeD Trench Length 87 ft Width ft. Gravel below pipe 0 ft. Total depth 12 ft. Eff. absorption area J.044 ftp Monitoring tube I Depression over field tj Date of adequacy test Results (PasstFaiQ For _ bedrooms Fluid depth in absorption field before test _ in. Water added_ gal. New depth_ in. Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN 3 type) N If yes, give date 6 D. LIFT STATION Date installed OR41M Size in gallons 250 ManholelAccess (Y/N) Y 'Pump on' level at 42 in. 'Pump ofr level at 4; in. High water alarm level at 44 in. Datum Bottom of Tank Cycles tested New Const. Meets alarm b circ ult requirements? Y E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAift station on lot On adjacent kits Absorption field on lot On adjacent lots Public sewer main Sewer /septic service line Public sewer manhole clearmxA Holding tank SEPARATION DISTANCES FROM SEPTIUHOLDING TANK ON LOT TO: Building foundation >5' Property line>' Absorption field >S Water main NIA Water service line >10' Surface water >IW Wells on adjacent lots >2W SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >Ir Building foundation >10' Water main >10' Water Service line >10' Surface water MW Driveway. parldrrpNehide storage >2S Curtain drain >W Wells on adjacent lots >20p F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and r 49th review of Municipal records that the above systems are in = conformance with MOA HAA guidelines in effect on this date. .z ;NICMn. L 40M Tze Engineers Printed Name Michael E Anderson. RE r►. /, No. cE-43rn tos- Date 2121f2004n HAA Fee E 57 �= Date of Payment Receipt Number it, 3953 (Rev. 12000) Waiver Fee $ 175 Date of Payment Z Receipt Number Feb 12 05 11:26a Larry M. McHain 907-333-6102 p.2 sN.NaswN'.r) ,orosm I.c+a om+u 3W IaL.YL') O.K O:,Ki Cf MDw K1Np W YbK i`t.Ot N i Jp• � . Prepared by PLOT PLAN ��s�E ,� Robert E. Johns, Jr. & Assoc. w. w. w...«.r_....._,rww, •� pp Professional Land Surveyors M ,,.., V ,„Yw.. r r „• r rw•,842 •� .. r p.. r r M r r we Awr.P N wnwn r •wr, ti r I / {: E. ' ANCHORAGE. TALASKA 99501 ScKK 111 401 RK Let S.F. 3 1°'�•w t•'• •N �" t 1 � � . .�.••7!GDRIVE . .'...'. . ..':. 16. / '..'f: i 26.0' C h ... ... .. c --- c 15.5• C. /T b n v L � NCO. N C.O.a S 90,00'00• E 2 LOT 1 N 202.16' CL 0 U m V Io m SURVEY CERTIFICATION • `�Owtl a *e,� Prepared by PLOT PLAN ��s�E ,� Robert E. Johns, Jr. & Assoc. w. w. w...«.r_....._,rww, •� pp Professional Land Surveyors M ,,.., V ,„Yw.. r r „• r rw•,842 •� .. r p.. r r M r r we Awr.P N wnwn r •wr, ti r I / {: E. ' ANCHORAGE. TALASKA 99501 ScKK 111 401 RK Let S.F. Rta Flat F:t Na 1°'�•w t•'• •N �" •..�. 9 tl I f FOUNDATION AS-BULT 01 . I :=; =1 .�.o•.. Dv14 �1^I•Y•¢ 2-7-05 Drown DY REJ Cnecaea Dy. REJ ROBERT �'l i wwr «wr�i w. Deq Drawn:..: 2-10-05 cnO: NSQ1960 w.o. 25-24 a e •off 4 21 r+'�.� Fw.LsTucroREASBULT "`.'...C..,.'r�""'-u .."^'eri � I •�1 ' pt''i � DF'vlptron: 0`'"•u....r+'~ �t4V�.� LOT 1, BLOCK 2, NOI?TF. T;GODS SUEDIVISIO:, ❑ LOT KNR,LY SURVEY TYPE ❑ SYMBOLS OLS FOUNDATION1 NULT D vu irIe,v[ AaT ASPHALT • SET REBAR� � DRANNCE ❑ ROTMAK ... AS-KLT ... LOT KRMI ... TOPV O FOUND r"AR �pp WOOD CCNCRETE IT 15 THE RESPONSIBILITY OF THE BV=ER OR OWNER, PRIOR TO ONLY THOSE IMPROVEMENTS ABOVE GROUND AND M515LL WILL BE CONSTRUCTION, TO VERIFY PROPOSED BUILDING 'GRADE RELATIVE SHOWN. FENCES. WMJ-% SEPTIC CLEAHOUTS. SIDEWALKS. DRIVEWAYS. TO FINISHED GRADE AND UTIUTY CONNECTIONS AND TO DETERMINE ETC.. ARE SHOWN IN THEIR APr•RO)CMATE LOCATION. ONLY. SNOW THE EKISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS MAY PREVENT SOME IMPROVEMENTS FROM BEING SEEN AND LOCATED. "ICH 00 NOT APPEAR ON THE RECORDED SUBDIVISION PUT. ALL OISTANCARE N w UNDER NO CIRCUMSTANCES SHOULD AN AS-SULT BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE UNES THE SURVEYOR TAKES RESPONSIBRFTY FOR THE VITAL TRANSACTION ONLY AND ASSUMES FINANCIAL UASNTY ONLY FOR THE COST OF THE SURVEY. LISTED DISTANCES PREVAIL OVER SCALING. REPRODUCTION MAY CAUSE ERRORS N SCARE ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779_[P February 21, 2005 .Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 1, Block 2, Northwoods Subdivision. Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer. The site for the alternate absorption trench for Lot 1, Block 2, Northwoods Subdivision Phase 2 is located approximately 1' from the south property line. This area was determined to have the best soil conditions on the lot for an absorption trench. The house was moved further to the south than originally planned causing both the primary and alternate absorption trenches to shift to the south. The primary absorption trench was constructed more than 10' from the property line. Placement of the alternate absorption trench at the location shown will not impact wells or adjacent septic systems. The subdivision is served by the Municipal water system and no wells are located within 200'. We therefore recommend a waiver be issued allowing the new trench to be constructed at 1' from the south property line if the use of the alternate site ever becomes necessary. Sincerely, // WYJtd'L A. L �.�..c Michael E. Anderson, P.E. ';J49th /.\ IV MICHAEL E. ANDERSON II, No. CE -4381 a RZunicipality of Anchorage (" : 0(i 1'.(1. 14,xP.CGR) • AnchurigG.Vasku 10.1519.65(1 • Tdcphune (!X17)333-MN11 • Fax (NM313-82N) 37(X)11mgaw Sheet •Anchnntgc,.Vaskn!)97,07 x�rx'.numLurg . J/ayor3lark Begich Iluil(ling Safety DhOslon 28 February 05 Anderson Engineering P.O. Box 240773 Anchorage, AK 99524 Subject: Waiver Request for Northwoods Subdivision Block 2 Lot 1 Waiver Request #WR050009 Parcel ID #051-741-18 Dear Mr. Anderson: Your request for a waiver of the required 10 feet from the Absorption Field to the Property Line is approved. The approved separation distance is 1 feet. This waiver approval applies to the existing Absorption Field to Property Line separations only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, C Jeff Poet Engineering Tech On -Site Water & Wastewater Program Community, Security, Prosperity Municipality of Anchorage Development Services Department t .. • +� Building Safety Division'49k`. , 0. On -Site Water and Wastewater Program ` 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchoragc.ak.us (907)343-7904 Waiver Review Worksheet WR#: 050009 PID#:051-741-18 HA#:050067 Permit#: 040185 Date Received: 2122/05 Legal Description: Northwoods Block 2 Lot 1 Engineer. Anderson Engineering P.O. Box 240773, Anchorage, AK 99524 Applicant: Ascend Construction Waiver Requested: l' separation distance absorntion field to Property line Criteria: Geology Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: ............... ................................................... .a........... Waiver is Granted: i/ Waiver is not Granted: List Conditions or Reasons for above: Date: 2 By: of Reviewer ..............................................•............................... Rec#: 83853 Amount: $176.00 Date Paid: 2/22105