Loading...
HomeMy WebLinkAboutCHARLICE TR ECharli'oce. Tract E- #068-01 1 - I I MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP251258 Work Type: Septic Initial Tax Code Number: 06801111000 Site Legal Address: CHARLICE TR E G:0464 Site Mailing Address: Owner: SCHUESSLER MARK A & DIANE MONT Design Engineer: ALASKA RIM ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 8/26/2025 8/26/2026 137503 Q Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: AY - Issued By: Date: Dater J 3 L_1W _j I'MUNICIPALITY OF AA Development Services Department On -Site Water & Wastewater Section ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 06801111000 Phone: 907-343-7904 Property owner(s) SCHUESSLER MARK A & DIANE MONTI Day phone Mailing address 19540 WINGHAM CIR; EAGLE RIVER, AK 99577 0000 Site address Legal description Charlice Tract E Number of Bedrooms 3 Engineering Firm ARE, LLC DBA ALASKA RIM ENGINEERING Building Permit Number TL 2— Not Applicable F] APPLICATION IS FOR: APPLICATION IS AN: (Z all that apply) Disposal Field F] Initial F-1 Septic Tank F1 Upgrade F-1 Holding Tank D Renewal El Privy ❑ Well 0 Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: Permit/Rush Fees: Waiver Fees: Date of Payment: Date of Payment: Permit No. W2�IZT Waiver No. May 2025 ARE, LLC dba ALASKA RIM ENGINEERING CONSULTING CIVIL ENGINEERS & PLANNERS 1920 Kentucky Derby Dr. Palmer Alaska 99645 Telephone: 907.775.2347 Email: alaskarimengineering.llc@gmail.com Professional Consulting --- Practical Solutions ARE LLC, project # 2025030 August 3, 2025 Municipality of Anchorage, D.S.D., On-Site Water and Wastewater Department 4700 Elmore Road, Anchorage, AK, 99519 Re: Charlice Tract E Parcel ID# 068-011-11 Subject: Initial Septic System Design Narrative and Permit Application Dear Plan Reviewer, The owner of the above site proposes to construct a 3-bedroom home. This design narrative proposes a plan to install a 1500 Gallon Septic Tank, and absorption field. The lot has an existing private well that does not have a pump. SOILS One test hole was excavated on July 2, 2025, and logged by Charles A. Leet, PE. The test hole was advanced to a depth of 19-feet. See the attached soil log which show the soil classification. No groundwater was detectable after required 7-day monitoring, see the attached soil logs. PERCOLATION TEST One percolation test was conducted between 4 and 5 feet below the ground surface. Results from the percolation test indicate the soils to have an application rate of. 1.2 gallons per square foot. Test hole and percolation test locations are indicated in the site plan accompanying this permit request. TOPOGRAPHY There are no topographical issues that will be created as a result of this installation. See the attached site plan for the topography. The average downgradient of the absorption fields is 15-16 percent. SEPTIC TANK REQUIREMENTS The new tank will be located outside of the 100-foot protective well radius. The new tank will be 1500 gallon tank meeting the AMC Chapter 15.65. The owner requested to upsize the tank. DRAIN FIELD DESIGN The proposed design flow rate of 450 gallons per day is required for a 3-bedroom home. The prescribed application rate is 1.2 gallons/ft2. The required absorption area is 375 ft2. Proposed is 5-wide 4-foot effective depth 38-feet in length; with those dimensions the drainfield will have a total of 380 ft2 of absorption area. The field will be constructed parallel to the existing ground contours. REPLACEMENT SYSTEM The proposed replacement system is parallel to the proposed field location with 10-foot separation. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251258, Curtis Townsend, 08/26/25 Charlice Tract E Parcel ID# 068-011-11 Page 2 of 2 Initial Septic System August 3, 2025 Alaska Rim Engineering Professional Consulting --- Practical Solutions ARE LLC, project # 2025001 SURFACE WATERS There is no surface water within 100 feet of the proposed system. Drainage arrows on the site plan indicate the slope and direction of stormwater runoff. (See attached site plan) WELLS & DRINKING WATER There are no water wells within 100 feet of the proposed system. The property is served by a private well, which has been drilled , but has no pump installed. SURROUNDING PROPERTIES We do not anticipate any adverse effects on the neighboring septic systems, reserve areas or drainage patterns by the installation of the proposed wells and septic system. Sincerely, August 3, 2025 Charles A. Leet, P.E. Principal Engineer Attachments: Permit application (previously submitted) Overall Project Area (page 1) Proposed Septic Plan (page 2) Septic Trench Detail (page 3) Trench Cross Section (page 4) Soil(s) log w/ percolation test data Asbuilt Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251258, Curtis Townsend, 08/26/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251258, Curtis Townsend, 08/26/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251258, Curtis Townsend, 08/26/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251258, Curtis Townsend, 08/26/25 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP251258, Curtis Townsend, 08/26/25 PL-o -F LA--1 po C, L LD r N TRACT D-1 S 89'54'10" E 283.18' V 100' TRACT E 100'VVELL RADIUS PROPOSED SINGLE STORY FRAME HOUSE 0) C�4 PROPOSED ,, x- -1 1 w SAS AREA p z cy N W51'40' W 454.57' vti `0 sl op 66,90�0 0 NOTES: Or1. SEE PLAT NOTES IF APPLICABLE 2 THIS PLOT PLAN IS FROM RECORD & PROPOSED INFORMATION ONLY 3 THIS LOT IS ZONED CER10 1190 N Helen Ln. Wasii!a, A'k 99654 Wow (������ Phone (907)376-9535 I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY , -TRAQI-E-Qf:fARLLaE . .... . . ... ANCHORAGE RECORDING DISTRICT, AND THERE ARE NO ENCROACHMENTS VISIBLE AT THE TIME OF THIS SURVEY, EXCEPT AS INDICATED, DATED THIS 13TH DAY OF JUNE 20 25 AT WASILLA, ALASKA- IT IS THE RESPONSIBILITY OF THE 6WNFmRs OR BUILDERS TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR ESTABLISHING BOUNDARY OR FENCE LINES THIS IS NOT A LOT CORNER SURVEY. JOB NO 25-114 FIELD BOOK/PG(S)' N/A � ') I J[SCALE I"=60' PLOT PLAN X AS BUILT DRAWN HW CKD WW OF A It# AW 4 C TH W�m �v- LS-6925 p SION 5-2025 TriVpmp PC • MUNICIPALI7YOFANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Permit Number: SWO40470 Legal Description: CHARLICE SUBDIVISION TRACT E Design Engineer: 0000 None Required Owner Name: JOHN DELLA CROCE Owner Address: NHN ROOP ROAD EAGLE RIVER. AK 99577 - Date Issued: Nov 03, 2004 Expiration Date: Nov 03, 2005 Parcel ID: 068-011-11 Site Address: NHN ROOP ROAD Lot Size: 137503 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of. ❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. THE INSTALLATION OF A WATER WELL SHALL MEET ALL THE ANCHORAGE MUNICIPAL CODE 15.55. PLEASE SEE THE ATTACHED SHEET "PERMIT REQUIREMENTS FOR A DOMESTIC WATER SYSTEM". IF THERE ARE ANY QUESTIIONS PLEASE CALL THE MUNICIPAL ON SITE WATER AND WASTEWATER PROGRAM AT 907-343-7904. Received By. Issued By. Date: I/A0)Y Date: fi lz o l Municipality of Anchorage • --�1 Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING AL Parcel I.D. char t t C", T Z 6�9- 1b l (- I Permit Number SW ZD Propertyowner(s) ��h ���. CroC� Dayphone 65q-c"3S ( Mailing address �-Q 77o Ge ( Zip Code 9f 'i S77 Site address Legal description (Lot, Block & Sub'd.) C- A Legal description (Section, Township & Range) Lot Size 61>3 Acres/Sq.Ft. THIS APPLICATION IS FOR: "ItDIT_r Zip Code ;Le., r' & Number of Bedrooms 4 Sewer Only ❑ Well Only Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Wj (Signature of property owner or authorized agent) Permit/Rush Fees: ISS 6D Waiver Fees: Date of Payment: 10 aQq Date of Payment: Receipt Number: /Copp( Receipt Number: (Rev. 09/04) M -W Drilling, Inc. •P.O. Box 110378*Anchorage, AK 99511• •907-345-4000 ♦ 907-345-3287 Fax* Job No.: 04-193 Parcel No.: 068-011-11 Permit No. SW040470 Groundwater Well As -Built & Lop ♦ Well Owner. Della Croce, John ♦ Use of Well: Domestic ♦ Legal Description: Charlice Subdivision, Tract E Construction ♦ Yale Depth: 285' ♦ Casing Size: 6" ♦ Cased To: 42.28' ♦ Material: A 53 Steel ♦DrillMerhod: Air Rotary _ Perf. ♦ Well Completion- Open end X Screen _ Perforated _ Method. ♦Sereen/Perforadon description: None ♦Grout Notes: (1) Sack- No. 8 bentonite granules ♦ Notes: ♦ Well Development: dledrod: Air lift )Totes. Well was explofracked ♦Static water level (SHT) 66' (above) (below) top of casing (TOC). ♦ Well1•leld test at 5-6 gallons per minute (GPAI)/gallonspeP Jhour{GP") jor 1 hours with 100% of drawdown (DD) from static level (SIFT). ♦bfethod. Airlift; frack job about doubled yield! ♦ Date of completion: 22 November 2004 Well Log ♦ Pump Install., Depth in feet from top of casing. Details of formations penetrated, size of material, color and hardness. 0 TO 2.5 Casing stickup 2.5 TO 5 Gravel pad 5 TO 7 Surface organics 7 TO 32 Boulder ravel: sand /silt 32 TO 41 Gravel: coarse, silt 41 TO 230 Bedrock: black -gray, siltstone ar illite with very small sea s in TO Sporadic fractures 230 TO 285 As above: more fractures- making 2-3 gpm before ex lofrack job TO TO TO TO TO TO TO r'� t,• tiVE"STSERG -President,-v,- J Mir ing, Inc. GWA-Certii ", cn vac or erGficate Nos{}{� (x, Contractors License No. i0on TO TO