Loading...
HomeMy WebLinkAboutT15N R1W SEC 18 LT 169T15N RIW SEC 18 Lot 169 #051-232-1-1 I Municipality of Anchorage ` Development Services Department \ Building Safety Division On -Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Boz 196650 Anchorage, AK 99519-6650 Page of www.d.anchorage.ek.us (907) 3437904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW030231 PID Number. 051-232-11 Name: Lon Parrish Wastewater System: ®New ❑ Upgrade Address: POS 6701SI Chua12k. AK, 99567 ABSORPTION FIELD pl ro: Number of Bedrmm O Deep Trench ® shallow Trench t] Bed 13 Mound a Dinar; LEGAL DESCRIPTION Ba Rama T"Depin ham od2" ads: 1.2 GPDIFT 7.0 Ft. ek n tut: Subdlviabn: DpM b PW b.aan ham arranal Anda: GnvN dWh berwN Me: 169 3.0 Ft. 4.0 Ft Tamen*: Ra^Ve: sei on: FR added a•va drpMl Pada. Grant L"M. 87 Ft. 40Ft. Well: ❑ New ❑ Upgrade GNN w"M: Number al la,aa: Dsar,, baleen ane•: 5.0 Ft. 1 — FL ClaeRlicatlon (Priv.n, A B. C): Trial DepM' caged b: Trial aWorpuon arN. F" Helens: v N Ft Ft 375+ Ft' D3034 & F810 Driller DMs Paed: Siatic Wes LaNt: b Ague'. Dale IrnMeaed. Ft Calkins Const. 08/26/2003 Meld: Puny set at Cas" 141,1,1 Above G .4 TANK GPH Fl FI SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic Absorption 4R Holding PublwiPrnratc ir. From Tank Field Station Tank SemarLine Anchorage Tank 1250 CO. wag 100'+ 100'+ NA NA 25'+ H.I.nW Steel Nunwenacon,°wr,en"' 1 2 sadaaewater 100'+ 100'+ NA NA LIFT STATION La Lim 5'+ 10'+ NA NA ue. w w. Dal Fuurcl.lbn 5'+ 10'+ NA NA am°aa M.et'L ""° Hyh """e1wm.L ti in. Qatari Drain NA *50'+ NA NA °ivp1."4 Ebcurtlimyac ,pvrbmndby. Renw.e: *none known BENCH MARK tank & field Insulated (4e) Lowuon ant qum. Bottom of siding landscaping boulders placed to Asu ned Ebvatbn: 100 FL prevent vehicle crossing over primary field Engineers Stamp -zatn W%% +PSE OF At %%I Inspections performed by: KND Engineering Inc. Dates: I st 8/26/2003 4 H �_ �/ a•a a Ne N •• •♦ eN ea/ Development Servi 2nd 8/27/03 es Department Approval 3'd 3/14/05 • •NN•. •• .N t N affu, Reviewed and approved by: D i (g •Kenneth 711 +i gFo.. is A��� SII, PROFS 16" \c% JAV&a r «WJ Only. AS -BUILT SYSTEM DETAILS/SITE PLAN T15N, R1W, SEC. 18, SW 1/4, LOT 169 169 RICIHNER ROAD A—C=29.35' _ C B—C=13.12' \ A—D=32.91' B—D=20.39' A—E=77.39' B—E=71.44' 1250 G, A—F=-- SEPTIC OF AL�91' 4U: *+� ' K. jr II.j�l�tos. 4 m 0 g 33' Patent Reserve FINAL GRADE Permit SW030231 PID#051-232-11 EXISTING _ `NOOO SCA 1 50' 0 0 J 40.7 ---I NTS PREPARED FOR: SCALE: 79.7 .a LON PARRISH P.O. BOX 670151 CHLIGIAK. AK 99567 (907) 688-1138 FIELD BOOKS souNoiwr. srwwx Am T: Dwa TIF AUD LttE' 03057 oC~m. DRAW: VBG a'EOam* KMD DATE: 1/17 DM NW105 " N` 03057 Mll !LU ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 �w - ' i MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Jul 02, 2003 Expiration Date: Jul 01, 2004 Permit Number: SW030231 Parcel ID: 051-232-11 Legal Description:(T15N Ri W Sec .18 SW 114 Lot 169.7 Design Engineer: 0070 KND Engineering Site Address: 19123 Richner Road Owner Name: Ron & Sandie Parrish Lot Size: 106286 SO. FT. Owner Address: P.O. Box 670151 Total Bedrooms: 3 Permit Bedrooms: 3 Chugiak . AK 99567 - This permit is for the construction of. Q Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By. Issued Date: Date: , t /� .. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program ' 4 5bil 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. azd _13 Z —11 Permit Number SW Property owners) Lon Parrish Mailing address (1) PO Box 670151 Chugia� Day phone 688-1138 AK 99567 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) T15N R1W .Seelig SWt/4 Lot 169 Legal description (Section, Township & Range) �6 Lot Size 1� o� CL Acres/ q.Ft. Number of Bedrooms 3 THIS APPLICATION IS FOR: Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. of property owner or authorized agent) Permit Fees: lyoc> Date of Payment: —1 of Receipt Number: ps, .14 4/c� (Rev. 17/00) 3 7 L' cl Q Waiver Fees: Date of Payment: Receipt Number: KND ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER. AK 99577-8 11/FAX (907)696-8111 June 30, 2003 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: New Sewer Permit —T15N, R1W, Sec 18, SW1/4, Lot 169 Gentlemen: The owner has requested we proceed forward to obtain a septic permit on the subject lot. On June 19, 2003 one testhole was performed for the proposed system. The results of this test is attached. The general slope of this lot is from southeast to northwest at a grades of approximately 5-23%. We have designed our system utilizing the existing testholes that were excavated for the proposed 3 -bedroom house. The lot will be served by an existing, individual well, located on the western portion of the lot. We propose to install one 5' wide shallow trench. Water was not encountered during the excavation or during monitoring. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696.6111/FAX 696-8111. Respectfully submitted, MD Engineering, Inc. Attachments: On -Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test Owners/ Excavators Specs WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLA I T15N, R1W, SEC. 18, SW 1/4, LOT 169 " WY ------- �P I 168A Ant — — — —L — — — —x..RM Et^S- -------Roo. NO PUBLIC WELLS WITMN Lar K P�SED SYSTEM. NO PRIVATE WELLS WITHIN Bar IS PROPOSED SYSTEM EXCEPT AS NOTE& NO SEPTIC SYSTEMS WITMN 2W' K PROPOSED WELL EXCEPT AS NOTEM OF Z4S f *r?11^ -K—EN-N-'S '� % CE -7116 � 1 t'ESSIOTt' 169 0 37 PRbnt Rsss . 179A/,, / N "s 'W ni / / / / / / / / _ — 3TRLK REI DESIGN DETAILS 3 BDRM X 150 GPD = 450 GPD 450 GPD/1.2 GPD PER SO. FT. (<1 MIN/IN.) = 375 SO. FT (375/5'(W)) X .5(RF) (4.0' GRAVEL) = 37.5 FT. TRENCH USE 1 TRENCH - 40 (L) X 5' (W) X 4.0'(D) Total depth of system Is 7.0' from original grade. Total depth of gravel below distribution pipe Is 4.0' . NOTES, 1. USE 1250 GAL SEPTIC TANK, INSULATE IF <4' OF COVER. 2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM. 3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK. 4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN. 3' COVER IF REQUIRED. 5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS, SEPTICS, LOT LINES, FOUNDATIONS AND ALL OTHER SETBACKS. PREPARED FOR: LON PARRISH P.O. BOX 670151 CHUGIAK, AK 99567 (907) 688-1138 FIELD BOOKS COMPUTED: BDIPSJARY: DRAM: STAI:PIG CHECKED: ASOMT. DAM DNa IBL: a,o: ACAD 1XL 03057.DWGI Joe "" 03057 Scale, 1'= 100' PAGE 1 OF 2 ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 I 11 WASTEWATER DISP❑SAL SYSTEM DETAILS T15N, R1W, SEC. 18, SW 1/4, LOT 169 18 K N D Q 100' tvQ O� o OQ QUO Q� O THO -1 - -- - - - - - _....0 _..... __. __.. _..._ _... �r11 PROPOS 1250 GAL T AL��'' 'w 4 F ........... �....-1 ,"SCE -7118 �bFESSIaX�V � PROPOS PREPARED FOR, LON PARRISH P.O. BOX 670151 Scales 1'= 20' CHUGIAK, AK 99567 PAGE 2 OF 2 (907) 688-1138 na.D BOOKS C� Tm: ZM ENGINEERING 90UNDMr. ORAM: sT� "0411' KMO 20441 PTARMIGAN BLVD. AS„ T-. ,AR EAGLE RIVER, AK 99577-8736 0. nc 0w: NW1054 :.....__...................:::: ::::::: :. ACAD nr' 03057.DWG doe ` 03057 (907)696-6111/FAX (907)696-8111 MD ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 SOILS PERCOLATION TEST Performed for. Lon Parish Date Project: T15N R1W SEC18 SW1/4 LOT 169 TEST HOLE # 03-1 Depth (Feet) 15- 16- 17- 18- 19- 20- ORG/OL SP/GP SW/SM -gray, mod fine sand W/ silt B.O.tI. Insitu material suitable as filter. HOLE PRESOAKED PRIOR TO TEST CE 7116 SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Groundwater encountered? NO What depth? NA Depth to water after monitoring? DRY Date? 6/26/03 Reading Date Gross Time Net Time Depth to Water Net Drop 1 6/23/03 1:00 - 6" - 2 1:05 5 min dry 6" 3 1:06 6" - 4 1:11 5 min dry 6" 5 ' 1:12 - 6" - 6 1:17 5 min d 6" 7 ' 1:18 6" - 8 1:23 5 min dry" 6" 9 1:24 - 6" 10 1:29 5 min d ' 6" I1 1:30 6" - 12 1:35 5 min dry 6" • Water Added Percolation Rate <1 (min/ in) Pere Hole Diameter 6" Test Run Between 4 feet and 5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. KININ ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 696-6111/FAX (907) 696.8111 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES AND MATERIAL SPECIFICATIONS LEGAL DESCRIPTION: T15N, R1W, Sec 18, SW 1/4, Lot 169 GENERAL: 1. The scope of this project includes the installation of a septic tank and/or drainfield to serve a singlrfamil residence on the referenced property as delineated on the attached Municipality of Anchorage MOA) permit and site plan. 2. Construction shall be in accordance with the approved site plan and design drawings; MOA permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. KND Engineering, Inc (KND) assumes no responsibility of the accuracy of the as -built survey .provided by the owner or owner's representative. _.... _ .. _._ __ _.. _. 4. The owner or contractor is responsible to notify the engineer of any discrepancies noted on the design plans or drawings prior to commencing work. These discrepancies could be, but not limited to, possible encroachments, surface water, varying soils, unplatted easements, types or use of dwellings on or adjacent to property, nearby public wells, etc. 5. The contractor shall be responsible for locating any necessary underground utilities, easements, property lines and surface water. The owner and/or contractor shall ensure, if deemed appropriate, that a registered land surveyor prior to construction flags all setbacks. 6. The contractor shall be responsible for verifying all pertinent separation distances and component layout. 7. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all lcachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. 8. The MOA Development Services Department On -Site Water & Wastewater Program must certify contractors installing wastewater disposal systems. Owners installing their own systems must also receive prior approval from said MOA Department. SEPTIC TANK / HOLDING TANK / LIFT STATION INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded with proper material and compacting to prevent damaging, settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above the final grade. 4. Septic tanks installed with less than 4 foot of cover shall be insulated. The contractor will ensure that the fill over the tank does not exceed the burial depth rating. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 feet from the tank. The second cleanout, in line, shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. Page 1 of 3 Reference: T15N R1W Sec18 SWV4 Lot 169 Date: 06/30/2003 Page: 2 of 3 7. All H.D.P.E. tanks shall have a vertical length of 4 -inch perforated drainpipe besides the tank extending to the bottom of the tank to above grade to monitor ground water. 8. All tanks shall be anchored when there is not enough adequate soil cover to resist buoyancy forces in high -groundwater areas. 9. All holding tanks and lift stations shall have an audible and visual alarm inside the residence. 10. All lift stations shall be wired in compliance with the Uniform Electrical Code and all MOA guidelines. 11. The contractor shall remove the old tank, or abandon it in compliance with the Uniform Plumbing Code. The contractor is solely responsible for the abandonment procedure. ABSORPTION TRENCHIDRAINFIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavaction become smeared, they must be raked or scratched (roughed -up) before gravel (sewer rock) placement. 2. Once the sewer rock is installed, the distribution pipe is installed level with the perforations facing downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitoring tubes shall be four- (4) inch diameter, installed approximately in the locations shown on the design, and be, a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. 6. All advanced technology waste water disposal systems (Advantex, Biocycle, Intermittent Dosing Sand Filter, etc...) shall be constructed, installed, maintained and monitored per manufacturer's specifications and MOA requirements. MINIMUM MATERIAL SPECIFICATIONS: 1. A MOA approved septic tank manufacturer must construct any septic tank proposed for installation. 2. The following pipe materials are MOA approved for use in septic system installations: Type of Pipe Perforated �Qlid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All Ieachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #2O0 sieve. If deemed necessary, a sieve analysis should be performed. 7. When sand is being used as a filter material, its gradation specification must conform to current MOA or DEC requirements. INSPECTIONS: Reference. T15N R1W Sec18 SWV4 Lot 169 Date: 06/30/20o3 Page:3 of 3 Typically there will be three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the sewer rock, distribution lines, standpipes, and cleanouts, but before the placement of the silt barrier, insulation, or any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required, especially with theinstallation of multiple trenches, sand filters, pressurized distribution systems, etc. The inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's activities. The owner shall contract with the contractor to perform the work outlined in these specifications and attached plans and in accordance with the attached MOA permit. All materials, components, and __.____construction practices shall comply with the MOA's and the State of Alaska's latest ordinances, regulations, or policies regarding wells and septic systems. The failure of the inspecting engineer to - — notice a material or construction non-compliance does not relieve the contractor of his/her responsibility to correct such deficiency. There will be no contractual arrangement existing between the contractor and KND Engineering, Inc. KND shall be the owner's representative and will inspect the work as stated above to document the contractor's activities. Final acceptance of the contractor's work rests with the owner and the MOA. KND shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. KND's inspecting engineer will not be responsible for the construction means, methods, and techniques, sequence, procedures or the safety precautions incident to this project. BY PROCEEDING FORWARD WITH THE INSTALLATION OF THE WATER AND/OR WASTEWATER SYSTEM (S), THE PROPERTY OWNER, CONTRACTOR, AND WELL DRILLER ACKNOWLEDGES HAVING READ AND ACCEPTED THESE SPECIFICATIONS. Owner.• Contractor: