HomeMy WebLinkAboutTHE TABLELANDS BLK 8 LT 9The Tablelands Block Lot 9 #051-801-49 Municipality of Anchorage Page 1 of 3 Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage. AK 995196650 www.cl.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SW040303 PID Number. 051.601-49 N.m.: S inellHomes Wastewater System: New AOb.r.. 1900 W. Northern Lights, Ste. 200 Anch., AK 99517 ABSORPTION FIELD P1101' 344.55678 NurD.r a B.rt.am. 5' Wide Trench LEGAL DESCRIPTIONTM Dft%h rrOr onV*9.w Bbtic lOt SrOaMuwe 8 9 .6 GPD/Ft' D -M W PF. eatmn Karn OnV* pr.W: 6 Ft. G= OW, e.rr.in pp.: The Tablelands 2 Ft. 4 To-Wip: RAW: 6sa Fa.ao.a.00.. orVrW V.O.. Ft rr..«E.npuc 1-3 Ft. 76 Ft. Well: AWWU Water System cr.M 5 Dwrfioe.n (PrrvM ., B, Cy TOW Degtr a..a b: Ft. oW w.aPoun.raa 2 >10 FE q rW: ,1.,A. R. R 760 w ASTM 3034 PVC D011.r: DM. br I swc Wrw Lr R Pisano's Dirtworks 9/3012004 rWe Pure sa.[ r A TANK DP" R. 1 SEPARATION DISTANCES STEP 7o Septic Absorption LIR Holding rlvate r .. From Tank Field Station Tank sewerLkte Anchorage Tank 1,250 wag >200' >200' NIA NIA >25' Steel s tww.W >100' >100' NIA N/A LIFT STATION — NONE ON LOT to two >5' >1' N/A WA 250 ca. AnchorageTankl0renco Fourdstim >5' >10' NIA NIA Y0 20 h �,. 15 k w..D, None Noted P" 'w. Orenco Allied Electric R.r..w: BENCH MARK Lot Line waiverAllowing rent o to o o ne. On n Finished Floor. 100.0 FE Engineer's Stamp .��gILc7ga OF C��•r�^mow` a•♦♦♦♦ Inspections performed by: T. Kimbrouqh Dates: 1" 9/30104 ; a9t `." Zn° 10/1104 Department of Health P and Human Services _ ices approval �� 4iMAEE Et RSp- W. / �f No. t ♦♦ Reviewed and approved by: /1, /,,,, , . ate: -� ##�`�Pte : 4♦aa::::��. Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastew.Iter Disposal System or Well Inspection Report Permit Number. SW04303 TBM - Page 3 of 3 PID No. 051-80149 f 100.14 x H N Y 99.11 f `--93.06 16 - 3/8' Diameter Holes II � 101.35 Each Lateral Ilul�-77.4 101.26 / 93.0 � / Pressurized Effluent Line 72 1' PVC Drninfleld Rock PROFILE AS -BUILT Scole: 1' - 20' NICKMX L MIDERSON No. CE -g81 Pres surized 1_97.1 Effluent Line I' PVC Dralnfleld Rock f `--93.06 16 - 3/8' Diameter Holes II � 101.35 Each Lateral Ilul�-77.4 101.26 / 93.0 � / Pressurized Effluent Line 72 1' PVC Drninfleld Rock PROFILE AS -BUILT Scole: 1' - 20' NICKMX L MIDERSON No. CE -g81 zr 4% /14e rS March 30, 2005 Anderson Engineering Attn: Mike Anderson P.O. Box 240773 Anchorage, AK 99524 ONTRA CT/NG e.RIC. FAX: (907) 522-6779 Subject: Lift Station Inspection @ Lot 9, Block 8 Tablelands This letter is to confirm that the lift station at Lot 9, Block 8 Tablelands was wired by a licensed Journeyman Electrician in accordance with the 2000 National Electric Code requirements. If you would like any further information, please feel free to call our office at the numbers listed below. Thank you. Sincerely, ALLIED ALASKA ELECTRIC, L.L.C. Janette L. Brown, Vice President/CFO cc: file P.O. Bar 876310. WasU z., Alaska 99687 (907) 373-3893 ofcl(907) 232-8687 CC111(907) 373-3894f"., i -d 468E -CLC (L06) 01440a13 a%sejd patijd dZS:Z1 so 0C aeW ■ ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX MEMORANDUM DATE: March 30, 2005 TO: Julie Makela, P.E. FROM: Mike Anderson, P.E. SUBJECT: Lot 9, Block 8, Tablelands Subdivision Septic System Inspection Report Certificate of Health Authority Approval Attached is a revised inspection report showing the correct number of bedrooms. We have also modified the compartment section to show a two compartment septic tanks with a 1 compartment lift station. A statement from the electrician is also included for your review. Please advise if further information is required prior to issuance of the Certificate of Health Authority Approval. D MUNICIPALITY OFANCHORAGE Development Services Department Onsite Water ti Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Jul 28, 2004 Expiration Date: Jul 28, 2005 Permit Number: SW040303 Parcel ID: 051.80149 Legal Description: THE TABLELAND SUBDIVISION BLOCK 8 LOT 9'" Design Engineer: 0014 Anderson Engineering Site Address: NHN SAMBAR LOOP Owner Name: �S�PIINgEpLL HOMES, INC Lot Size: 61493 SO. FT. Owner Address: 09 SAMBAR LOOP Total Bedrooms: 3 Permit Bedrooms: 3 EAGLE RIVER. AK 99577 - This permit is for the construction of: ❑,/ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 9/6/004 GtIX)o -1.5' hJ5 '�n Tt►a. m'�1�,a. �� a�?o�ca. o..d ;c� Jt�a. (�coco�, ni- 6UN'\-\ o. VCb0%.d. �ccl Received JNYI)i catu•Z' 1bQ0M4c". Saa. QACa- nCa . Issued By: Date: 28 n Municipality of Anchorage Development Services Department Building Safety Division _ On -Site Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 051 -SN -LO Permit Number SW Property owner(s) Soineil Homes, Inc. Day phone 3445678 Mailing address (1)1900 Northern Lights Blvd., Suite 20i Anchorage, AK 99517 atq address (2) NAO SAmW LOOP C- YL Zip Code q065 -4-q Legal description (Lot, Block & Sub'd.) Lot 9. Block 8. Tablelands Subdivision Legal description (Section, Township & Range) Lot Size 61.493 Acres/Sq.Ft. Number of Bedrooms Three (3) 11111 1 4[91-Yilei MI-lile1z; Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. E (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number. (Rev. 17100) T SCF 55�-5�pn, Waiver Fees: Date of Payment Receipt Number. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 September 23, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 9, Block 8, Tablelands Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The absorption trenches for Lot 9, Block 8, Tablelands Subdivision are located at the highest point on the lot near the front to provide as much separation from groundwater as possible. The new trenches will be constructed within 1' of the lot line due to the narrow configuration of the lot. The subdivision is served by the Municipal water system and no conflicts exist between wells or other septic systems in the area. Placement of the new absorption trenches at the locations shown will not impact wells or adjacent septic systems. We therefore recommend a waiver be issued allowing the new trenches to be constructed at 1' from the northwest property line. Sincerely, 4 Q j a/J Michael E. Anderson, P.E. 49th !\ MICHAEL E. ANDERSON R No. CE -ASI f Ahinicipality of Anchorage J P.O. Na 1!NNw511 • :\nchumg�•, ,\I;ukn !Nlil!6141LM1 • Tclrphonc (!X)7):13:1 fi:S111 • Fax (!N)7) a7:4 ft_INI 47(X) 14rngnw Sl reel • .\nchnn;ge, ,\In.lm !X15117 ximmitmLorg Mayor Mark ISc��icll Iluilding Safety Dh islon 9/27/2004 Anderson Engineering P.O. Box 240773 Anchorage, Alaska 99524 Subject: Waiver Request for The Tablelands Subdivision, Block 8, Lot 9 Waiver Request #WR040067 Parcel ID #051-801-49 Permit # SWO40303 Dear Mr. Anderson: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to property line has been approved. The approved separation distance is 1.0 foot. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, �V Julie Makela, P.E. Civil Engineer On -Site Water & Wastewater Program Community, Security, Prosperity Municipality of Anchorage Development Services Department • Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchoragc.ak.us (907)343-7904 WR#: 040067 PID#:051-801-49 Date Received:/19 6Y1004 Waiver Review Worksheet HAM _ Permit#: SW040303 Legal Description: The Tablelands Subdivision. Block 8. Lot 9 Engineer. Anderson Engineering Applicant Soineli Homes. inc. Waiver Requested: Lot Line Waiver Criteria: Geology A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: Points: ............................................................................... Waiver is Granted: Waiver is not Granted., List Conditions or Reasons for above: ......................................... Rec#: 58620 Amount: $175 Date Paid: 9#'/2004 .................................... ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX Z r4 u•:G►FBIIT, DATE: September 16, 204 TO: Julie Makela, P.E. FROM: Mike Anderson, P.E. SUBJECT: Lot 9, Block 8, Tablelands Subdivision SWO40303 Septic System Revisions We have revised the septic system design for Lot 9, Block 8, Tablelands Subdivision to provide additional separation from groundwater. Test Hole Number 2 currently has approximately 5' of water in the monitor tube. Test Hole Number 1 remains dry and has been dry since it was originally placed. We have since placed Test Hole Number 3 near the front of the lot. The depth of the hole is 20' and no groundwater was encountered nor has any been monitored. The elevations at the surface and bottom of both Test Hole Numbers 2 and 3 are shown on the attached drawing. We are confident the revised design will provide a minimum of 4' separation from groundwater during any season of the year. Please review the attached design for this lot and revise the septic system permit accordingly. Let me know if you have further questions or comments. #L- 5- e Gam- 0 0.\ ti01,x•4, a"° � � y, •I' V) 00 0 8 Ft FP 4i y zY PTS � z o MM a vi J W MI Of C4 _a F rn� w f- �oJ ti Q 4 k J Z. 4�0^� y��h � ■ y y W W N W Fol F 7NN ' r W Q O N x LOT 9, BLOCK 8, TABLELANDS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home 5' Wide Trench System Perc. Rate: 30 Min./Inch 1,250 Gallon STEP Tank Application Rate: .6 GPD/SF 4' Drainfield Rock 3 Bedrooms " 150 GPDBedroom = 450 SF Absorption Area 450 SF/.6 GPD/SF/5 SF (Wdth)' .5 (Red. Factor) = 75 LF Trench Length THEREFORE: Construct 2- 38' Long x 5'Wide x 4' Effective Depth Absorption Trenches. Flow Line Elevation in Trenches to be 2' Below Original Ground Surface. Total Depth to be 6' Beiow Existing Ground. Provide 2" Insulation and 2' Cover Over Absorption Trench and 4' Cover Over Septic Tank. 6" 4'0" Natural Backfill 5' F-1 32 3/16" Diameter Holes 16 Holes Per Lateral @ 2.4' Spacing TYPICAL 5' WIDE NOTE: 2" Insulation and Geotextile Fabric 1.25" Perforated PVC (Holes Down) Drainfieid Rock H SECTIO"' Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 10' Separation From Water Service Line. Minimum 100' Separation From Surface Water or Streams. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 9, BLOCK 8, TABLELANDS S/D PERFORMED FOR- SPINFLL HOMES DATE: 9/18/2004 PROJECT No • M0452 PARCEL ID4- TECHNICIAN: T.L. KIMBROUGH DEPTII TEST HOLE #3 Ocel> I 2 READING OB NET TIME (MINUTES) 3 NET DROP (INCHES) 9/18/04 4 5 1:15 6 7 2 GRAY SILTY -SANDS 30 7.25" W/GRAVELS SOME COBBLES TO 10' 8 MEDIUM COMPACTION 9 GM II l 1 1 1 1 1 M to lo;ol` �y OI 49th MICHAEL E ANDERSM ti No. CE -138I f SITE PAN TH2 0 TFI I CURB KEY TH30 SFE FUTURE ASM111.T 0% DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) WATER F (INCHES) NET DROP (INCHES) 9/18/04 1 1:15 8.5" 2 1:45 30 7.25" 1.25" 3 1:46 8.5" 4 2:16 30 7.5" 1" 5 2:17 8.5" 6 2:47 30 7.5" 1" PERCOLATION RATE• 3O (MINANCH) PERC. HOLE DIA. INCHES) TEST RUN BETWEEN: 4 FT. and--5--FT. WAS GROUND WATER ENCOUNTERED? NO IF YES @ WIIAT DEPTII') DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING: 9/23/04 COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. SAME SOIL MATERIAL AS FOUND IN TEST HOLE N0. I. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE- PRESSURE DISTRIBUTION CALCULATION Elevation at Highest Discharge Point 95' Pressure at Highest Discharge Point 5' Head Liquid Level in Tank (Elevation) 91' Diameter of Holes In Distribution Line .1875" (3/16") Diameter of Distribution Line 1.25" Hole Spacing in Distribution Line 2.49. Length of Transport Line 10' Diameter of Transport Line 1.5" Q = 12.4cW= 12.4(.1875)(.1875)Y5— = 2.4(.1875)(.1875)Y5_ .9748 GPIWOrifice .9748' 32 = 1.2 GPM TDH = (100-91) + .0192(31.2)(31.2) + .000995(10) (31.2) (1.5) • 67 = 9 + 18.7 + .80 28.5 Therefore 32 Orifices @ 2.4' Spacing With 32.2' Total Dynamic Head. C' 200.0C T 9 S MO M - + ; yi-i f- 1 { + 1 I . ... : . ... ' EFFLUENT PUMPS 1 ; : 1 �„t•„�,_ .»I�.» 1 Iii , if 1/2H to] 1/2H I I { y� SINGLE PHASE,60HZ 1 1 i + 1 1, 1 { i _1 if 115/230 VOLT + + PC#2 20 OSI 15 HHF - 9 stage -i- t.. 1:. :....I.... f 1 •..1._ .: t 1 i....f_ ... }I LL i L_u_++: -i 1 -l'1 '• I I If i i i i i i i 1 1 1 1 if 1 i i i 1 1 1 I i 1 If t •200SI10HHF-7sta •4 I i_ �r � i I.R...k..i..r -1--+-i-i-=r•-.I+-r-°,�- .•L+-♦� -.♦ If f ... .rt -* .ll . __SiY�'IiiA. ,, :1 t , . 1++, :1 , 11 1{1 _ ..._iIf I I ' 1 i' N_♦N.• fill -!T• ••f 4" 1 M1 i:, 1 1 i-»-'~ I i IN If i : ... .. .. _L..i... I ... L...L.-L '-L 1 120 _L!..1 OSI OS HHF - 5 44 i 1+ :I i iii 1177. i i i if 1•. 1_. i.:l i. i_ �,..:. _i 7 1 44. ..1_1- 7 .+_r;..l.. ..._ it4. 1 i! .icy. -1_i_..i-i-f 1 I ' { t I j l, l + i< 1 2—'4 If 7 :«.«. {i �rT..,.i4 -SI 0 O 05 iiIi 2 stage' ..I.._.. ..,.. if _ 1 ♦ 4-44 �•i � in 15V"_ t'%.i { » 1 h- 1_ 20 OSI OS HHF- 5 stage _ , '- a1]S1ile i? '♦' � w / 1/4" flow controller y I 5.00 10.00 15.00 20.00 25.00 30.00 35.00 40.00 45.00 50.00 NET DISCHARGE, GPM 3 2 Gim ORENCOSYSTEMS,INC2626 COLONIALROAD ROSEBURG,OR97470 (503)673-oi� S ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX July 24, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 9, Block 8, Tablelands Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 9, Block 8, Tablelands Subdivision intends to construct a new three- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is served by a community water system and no conflicts exist with adjacent septic systems or wells. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The water service line is also shown. The current drainage pattern along with spot elevations are identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. A test hole recently placed on the lot indicated silty sand and gravel in the area of the absorption trench. The accepting soils were tested and found to have a percolation rate of 30 minutes per inch. No groundwater was found In Test Hole No. 1 during placement and none was noted during the monitoring period. Test Hole No. 2 indicated groundwater at approximately 6', but the surface of Test Hole No. 2 is approximately 10' lower than Test Hole No. 1. Our design includes the placement of a new 1,000 -gallon septic tank along with a 75' long by 5' wide by 4' effective depth absorption trench to collect and treat the sewage generated in the house. The bottom of the trench will be 6' below the surface. The distribution pipe will be 2' below the surface. A minimum of 3' of cover will be placed atop the trenches and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at shallow grades from southeast to northwest as shown on the Site Plan. The absorption trench will be constructed parallel with the Lot 9, Block 8, Tablelands July 24, 2004 Page Two slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. ySiinncerelyy, O C� Michael E. Anderson, P.E. Attachments U N-CNaEL E ♦NDM S No CE -4381 LOT 9, BLOCK 8, TABLELANDS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom House 5' Wide Trench System Perc. Rate: 3060 Min./Inch 1,000 Gallon Septic Tank Application Rate: .45 GPD/SF 4' Drainfield Rock 3 Bedrooms X 150 GPD/.6 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/5 SF " .5 (Red. Factor) = 75 LF Trench Length THEREFORE: Construct a 75' Long x 5' Wide x 4' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 2' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Provide 2" of Insulation and 2' of Cover if Necessary. ural 4 15^ I I Backfill xtile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) �•�p,..••" "- NOTE: Grade Area Over Trench to Drain Away. Cad Minimum 6' Separation From Bedrock. 44 — Minimum 4' Separation From Groundwater. Minimum 10' Separation From Water Services in the Area. �� MK YELEM OENsw Minimum 100' Separation From Surface Water or Streams: �i� r,' No. CE. l } MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION- LOT 9, BLOCK 8, TABLELANDS S/D PERFORMED FOR- RPINFLL HOMES DATE: 7/13/2004 PROJECT No - M0452 PARCEL ID,4- TECHNICIAN: T.L. KIMBROUGH DrMl TEST MOLE # 1 Type of Test: ® Percolation Ire) 1 2 3 4 5 6 7 8 9 10 11 1 I 1 I 1 1 COMMENTS: OB DRY REDDISH BROWN SILTY - SANDY -GRAVELS GRAY SILTY -SANDS W/GRAVELS SOME COBBLES TO 10' MEDIUM COMPACTION GM L• eM Opo di SITE PAN TH2o T�I I CURB KEY DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) WATERF (INCHES) NET DROP (INCHES) 7/13/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 10:30 12.0" 2 11:00 30 10.875" 1.125" 3 11:00 12.0" 4 11:30 30 10.875" 1.125" 5 11:30 12.0" 6 12:00 30 11.0" 1.0" PERCOLATION RATE 30 (MM/INCH) PERC. HOLE DIA. 6 rINCIIES) TEST RUN BETWEEN: 4 FT. and -5 --FT. WAS GROUND WATER ENCOUNTERED? NO IF YES @ WHAT DEPTH' DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING: 7/22/04 NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON TTIIS DATE- 7/24/2004 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 9, BLOCK 8, TABLELANDS S/D Vi, PERFORMED FOR- SPINELL HOMES DATE: 7/13/2004 PROJECT No' M0452 PARCEL IDX TECHNICIAN: T.L. KIMBROUGH or•.FrnI TEST HOLE # 2 Type of Test: ® Percolation (toot) 13 14 15 16 17 18 19 Ansi,♦ / 49th . NEL L ANDERSEN N0. CE -4381 / SITE PAN C TH2O 0 THI CURB KEY 11 0`Yo DATE READING GROSS TIME (MINUTES) OB 1 NET DROP I (INCHES) 7/13/04 DRY REDDISH BROWN SILTY - 2 1 SANDY -GRAVELS 8.5" 3 2 4 30 7.875" 1.125" 5 3 GRAY SILTY -SANDS 6 8.5" W/GRAVELS SOME COBBLES TO 10' 4 2:11 MEDIUM COMPACTION 7 1.125" GM 8 2:12 8.5" 9 WATER SEEPAGE 10 30 7.5" 1 BOH it 13 14 15 16 17 18 19 Ansi,♦ / 49th . NEL L ANDERSEN N0. CE -4381 / SITE PAN C TH2O 0 THI CURB KEY 11 0`Yo DATE READING GROSS TIME (MINUTES) NET TIMEJ (MINUTES) Dy ATERP (INCHES) NET DROP I (INCHES) 7/13/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1:10 8.5" 2 1:40 30 7.875" 1.125" 3 1:41 8.5" 4 2:11 30 7.875" 1.125" 5 2:12 8.5" 6 2:42 30 7.5" 1.O" PERCOLATION RATE; (MIN/INCtI) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4 FT. Dnd--5—FT. WAS GROUNDWATER ENCOUNTERED? YES IF YES @ WIIAT DEPTH'' 91 DEPTH OF WATER AFTER MONITORING: 5.8' DATE OF MONITORING: 7/22/04 COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE- 7/24/2004 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 9, BLOCK 8, TABLELANDS SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,000 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 75' long X 5' wide X 4' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 2' below the existing ground surface. Total depth of the trench will be 6' below the existing ground surface. A separation distance of 10' from any water service and 100' between the septic tank and absorption trench and any surface water must also be maintained. A minimum of 3' of fill is required over the absorption trenches and 4' over the septic tank. In lieu of the required fill 2" of insulation and 2' of fill may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,000 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 9, Block 8, Tablelands July 24, 2004 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 9, Block 8, Tablelands July 24, 2004 Page 3 of 3 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. "1p� Municipality of Anchorage yl tl -� Development Services Department Building Safety Division ' On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING C0,577 Parcel I.D. 051-801-49 COSA # Expiration Date: O 1. GENERAL INFORMATION Complete legal description Lot 9, Block 8, The Tablelands Subdivision Location (site address) 22590 Sambar Loop Chugiak, Alaska 99567 Current Property owner(s) Christopher Nelson Day phone Mailing address Lending agency Mailing address Real Estate Agent Mailing Address 22590 Sambar Loop Chugiak, Alaska 99567 Day phone Jules Graeber/Keller—Will. Dayphone (907) 355-8765 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual Well ❑ Individual Water Storage ❑ Community Class A Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding Tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for.a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Pinard Enpineerinp Phone(907) 357-3647 Address PO Boz 871347 Wasilla, Alaska 99687 Engineer's Printed Name Paul E. Pinard, P.E. Date:, 4-iC'_ 4eeie•^�•�. �se•. �'e�1 V„ ec'eb•Ge• OTffs• a of to ee r•; Pa -A E. Pinard 5. DSD SIGNATURE G' ';• C-47B2••e•�!;; Approved for 3 bedrooms. ��xi� e`7• • E4°t(5� Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other_ By: Original Certificate Date: 3-9-03 (Rev 11,05( Municipality of Anchorage `• "` Development Services Department ° Building Safety Division" On -Site Water 8 Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Lot 9, Block 8, The Tablelands Subd. Parcel ID: 051-801-49 A. WELL DATA (� Well type _(j_ �t ] b�. ,_,If A. B, or C provide PWSID Wt Date completed _ Sanitary seal (YIN) _ Total depth ft. Date of test Static water level Well production Cased to ft. FROM WELL LOG WATER SAMPLE RESULTS: ft. Coliform colonies/100 mL Nitrate mg/L Arsenic: _ ug/L date of sample: _ B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Well Log (YIN) Wires properly protected (YIN) Casing height (above ground) in. AT INSPECTION ft. 9 - p.m - Other bacteria colonies/100 mL Collected by: Date installed 9/30/04 Tank size 1250 gal. Number of Compartments 2 + is Cleanouts (YIN) Yes Foundation cleanout (Y/N)Ye is Depression over lank (YIN) No High water alarm (YIN) NA Yes Date of pumping 3/2/09 Pumper Sanitary Pumpers C. ABSORPTION FIELD DATA Date installed 9/30/0 Soil rating (g.p.d./fe aiXl;?XSM;A 0.6 System type 5 wide Shallow Trench Length 78 ft. Width ft. Gravel below pipe L ft. Total depth 7.5 ft. Eff. absorption area 780 ft' Monitoring tube Yes Depression over field No Date of adequacy test 2/11/09 Results (Pass/Fail) Pass For 3 bedrooms Fluid depth in absorption field before test 1 in. Water added 500gal. New depth 6 In. Elapsed Time: 75 min. Final fluid depth 1 in. Absorption rate >= 450+ g.p,d, Any rejuvenation treatment (past 12 mo.) (YIN 8 type) None Known If yes, give date D. LIFT STATION (STEP) Dateinstalled 9/30/04_ °Pump on' level at ZLL; in. Datum. E. SEPARATION DISTANCES Size in gallons Z.So 'Pump off" level at Cycles tested Z Manhole/Access (YIN) Yes High water alarm level at / $ in. Meets alarm 8 circuit requirements? _ Ye s SEPARATION DISTANCES FROM WELL ON LOT TO: NA — PUBLIC WATER SYSTEM — NO WELL ON LOT Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer /septic service line On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank Animal containment areas Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 51+ Property line 10 r+ Absorption field 5 r+ Water main 101+ Wells on adjacent lots w Water service line 10 r + Surface water 100 r + SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 11+ Waiver Building foundation 101+ Water main 101+ granted Water Service line 10 r + Surface water 1001+ Driveway, parking/vehicle storage _5 r + Curtain drair>gone known Wells on adjacent lots 2001+ on lot F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Paul E. Pinard, P.E. Date 3/4/09 COSA Fee $ T 9 '0 Date of Payment 73 --C 0 n Receipt Number $ 3 0 „2 (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number ;:'; Z. Pinard �►s� ��i'�,•^ CE -4703 '; PINARD ENGINEERING al Paul E. Pinard �y1 Z^•, Registered Engineer/AK & ID P.O. Box 871347, Wasiila, AK 99687 (907) 357-ENGR(3647) ONSITE DRINKING WATER AND SEWER SYSTEM ENGINEER'S EVALUATION PROPERTY DESCRIPTION: LOT 9, BLOCK 8, THE TABLELANDS SUBDMSION This property Is developed to serve a single-family residence with a total of 3 bedrooms. Owners Name(s): Christopher Nelson Owners Address: 22590 Sambar Loop Chugiak, Alaska 99587 Buyer's Name(s): Ron Dunton Buyers Address: �f �1NSITE DRINKING WATER SYSTEM: �_This property is served by a Public Water System approved by ADEC. recent drinking water sample was tested at an ADEC certified laboratory and was found to meet current ADEC drinking water standards for total coliform bacteria. NOTES: ONSITE WASTEWATER DISPOSAL SYSTEM: A new wastewater disposal system has been installed. Based on periodic visual observations, it appears this system was constructed In general conformance with current 18 AAC 72 regulations and ADEC policies. This wastewater disposal system was Installed by an ADEC Certified Installer and approved by ADEC. The existing wastewater disposal system was tested In accordance with current MOA and ADEC policy and found to be 1(� ,,� X—on perating satisfactorily. The readily identifiable features of this system were observed and documented. ,}g1 XX It appears that this system meets requirements of the ADEC and the MOA, based on record information at the /". MOA. This system does not meet the horizontal separation distance requirements of 18 AAC 72 regulations and conformance with the vertical separation requirements of these regulations, to seasonal high groundwater and impermeable layers, Is unknown. Components are unknown and it Is undocumented with ADEC. NOTES: The septic tank was Pumped on 31219. This report does not constitute a guarantee of any kind, explicit or Implied, as to the future performance of this water supply or wastewater disposal system. It does accurately portray the conditions found on the date they were tested and/or documented. DATE 3 4 oq PAUL E PINARD CE,4793 PINARD ENGINEERING P.O. Box 871347 Wasilla. AK 99687 (907) 357-ENGR (3647) ADEQUACY TEST LOCATION: Lot 9, Block 6, The Tablelands Subdivision APPLICANT: Christopher Nelson 22590 Sambar Loop Chugiak, Alaska 99667 SEPTIC TANK TYPESIZE: Stmill250 Gallon STEP, per MOA Records ABSORPTION SYSTEM: 5 Wide Shallow Trench, per MOA Records DAILY FLOW. 3 BEDROOMS x 150 GAL/BR a 460 Gallons TEST DATA JOB NUMBER: 09425 DATE OF TEST: 2111109 FIELD STAFF: PJ Pinard NUMBER OF BEDROOMS: 3 SCUM: 0.0' SLUDGE: Minimal NEEDS TO BE PUMPED: Yes No XX CURRENTLY IN USE: Yes XX No Time Flow Rate Volume Cumulative Volume Septic Tank Septic Tank Sol Absorption System Comments AM (GPM) (GALS) (GALS) Liquid Level • A Level Monitor I Tube 1• I A SAS Level Monitor Tube 3• A SAS Level 10:25 6.7 - 4.0' - 0.1' 0.1' - Start Flow - Meter 404010 10:40 6.7 100 100 4.1' 0.1' 0.1' 0.0' 0.2' 0.1' 404110 10:55 6.7 100 200 4.1' 0.0' 0.2' 0.1' 0.2' 0.0' 404210 11:10 6.7 100 300 4.1' 0.0' 0.3' 0.1' 0.3' 0.1' 404310 11:25 6.7 100 400 4.1' 0.0' 0.4' 0.1' 0.4' 0.1' 404410 11:40 - 100 500 4.1' 0.0' 0.5' 0.1' 0.5' 0.1' Stop Test- 404510 RECOVERY *ALL MEASUREMENTS IN FT. TEST: PASSED XXX FAILED COMMENTS: There Was 0.1' of measurable liquid In the SAS MTs prior to beginning the test. With the addition of 500 gallons to the system (mon than the design dally now), the levels rose to 0.5' In the MTs, leaving most of the ED of the SAS still available. Recovery measurements showed satisfactory absorption. Reviewed Dy: Paul Pinardl -10 Date: 2114109 Time SAS MTI SAS MT3 12:05 PM 0.3'/-0.2' 0.3'/-0.2' F 9:45 0.17-0.2 0.1'/-0.2' *ALL MEASUREMENTS IN FT. TEST: PASSED XXX FAILED COMMENTS: There Was 0.1' of measurable liquid In the SAS MTs prior to beginning the test. With the addition of 500 gallons to the system (mon than the design dally now), the levels rose to 0.5' In the MTs, leaving most of the ED of the SAS still available. Recovery measurements showed satisfactory absorption. Reviewed Dy: Paul Pinardl -10 Date: 2114109 Municipality of Anchorage �- Development Services Department Building Safety Division Onsite Water and Wastewater Program . , „ ;T1 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcell.D. 051-801-49 HAA# Expiration Date: i�5V4 l� 1. GENERAL INFORMATION Complete legal description Lot 9 Block 8 The Tablelands Subdivision Location (site address or directions) 22590 Sambar Loop Current Property owner(s) Soineli Homes, Inc. Day phone 3445678 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address 1900 Northern Llahts Blvd. Anchorage, AK 99517 Unless otherwise requested, HAA wN behold by DSD for pickup. Day phone Day phone 2.. NUMBER OF BEDROOMS: Three 3 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site 19 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ® Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of Ube (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health'Authority Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my sgal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined in the • Ap^roval Gi Veiin�s for this application, shows that the on- site water supply and/or wastewater lisp::.. .,a' a.i i<. i ��.. sa!e• , • :'bnal and adequate for the number of bedrooms and type of structure indicated herein. I furtl ger verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522.7773 Address _P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 3/23/2005 S. DSD SIGNATURE _Z Approved for Disapproved. {'7> - bedrooms. Conditional approval for Additional Comments bedrooms, with the following stipulations: D VA TEWATER PROGRAM— o- s Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By: Original Certificate Date: MWAM Municipality of Anchorage �, •. • Development Services Department Building Safety Division On -31e Wnt: • v. N'^stswater Program a' ', wt ,' %agaw St. P.O. Box 196650 Arxnorage, AK 99519.6650 www.ci.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 9. Block 8. The Tablelands Subdivision Parcel ID: 051.601.49 A. WELL DATA Well type _ Date completed _ Total depth ft static water level If A, B, or C provide PWSID & Sanitary seal (YIN) Cased to fL FROM WELL LOG n Well Log (YIN) Wires properly protected (YIN) Casing height (above ground) in. AT INSPECTION I Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform oolonies/100 ml. Nitrate mg.A. Other bacteria colonies/100 mi. Date of sample: Collected by: B. SEPTICIHOLDING TANK DATA Tank Type/Material SeoticISTEP Data installed 913012004 Tank size 1250 gal. Number of Compartments I Cleanouts (YIN) Y Foundation desnout (YIN) Y Depression over tank (YM) N High water alarm (YIN) Y Date of pumping Pumper New Constmctlon C. ABSORPTION FIELD DATA Date installed 101111004 Soil rating (g. p.d./fe or fe/bdrm) .6 GPD15F System type 6 Wide Shallow Trench Length 76 it. Width S it. Gravel below pipe 4 it. Total depth 7-9 fL Eft. absorption area Z§Lft' Monitoring tube X Depression over field N Date of adequacy test Results (Pass/Fall) For _ bedrooms Fluid depth in absorption field before test _ in. Water added_ gal. New depth_ in. Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed 913012904 Size in gallons 250 Manhole/Access (Y/N) Y 'Pump on' level at 20 in. 'Pump oft' level at jQ in. High water alarm level at 15 in. Datum Too of Vault Rim Cycles tested New Construction Meets mann & circuit requirements? Y E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAtft station on lot WA Absorption field on lot WA Public sewer main WA Sewer /septic service line WA On adjacent lots WA On adjacent lots WA Public sewer manhole/cleanout WA Holding tank WA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >S Property line >2' Absorption field >S Water main >10' Water service fine >10' Surface water Aw Wells on adjacent lots >20T SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >1 Ar Building foundation >10' Water main MW Water Service line >10' Surface water MW Driveway, padcinglvehMe storage >S Curtain drain None Noted Wells on adjacent lots >2W F. COMMENTS G. ENGINEERS CERTIFICATION 1 certify that I have determined through field inspections and moi. 49th review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. •;roterc� c wmouom Engineers Printed Name Michael E Anderson. P.E. �e. '•.4NM CE -un / Date 312312005 e19diESSt4 HAA Fee $ S-7 bar-_-- Waiver Fee $ Date of Payment 3 ' Z r-0 S' Date of Payment Receipt Number S Receipt Number, (Rev. 12MM a n M A rn 'n 0 b 0 c 2004-25 THE TABLELANDS LOT 9, BLOCK 8 61,493 S.F. N 89'56'28'E 80.46- 0) AS -BUILT GASTALDI LAND SURVEYI JEFF A. GASTALDI, R.L. 4726 WEST 88TH AVEN ANCHORAGE, ALASKA 99 PHONE 248-5454 GRID NW 1559 F.B. 04-13 DATE 2/4/2005 JOB NO. TLS98 I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT N ENCROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, SPVENANTS OR RESTRICTIONS WHICH DO qOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION Oq FOR ESTABLISHING BOUNDARY OR FENCE LINEI. ANCHORAGE RECORDING DISTRICT, ALAS A NOTE: NO CORNERS SET THIS DATE. OF Ak 1 k so *. . 0 *; 49IH /.. .... ....... .......0 1✓ a Jeffery A. Gaetaldl . c Alr AV #°iP so.� LS -6091 �;. � �'�Air `oyeealon00-*