Loading...
HomeMy WebLinkAboutMCKINLEY VIEW ESTATES BLK 2 LT 19McKinley View Block Lot 19 #051-792-23 .r Municipality of Anchorage ' Development Services Department Building Safety Division On -Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Boz 196650 Anchorage, AK 99519-6650 Page of www.d.anchorage.ak.us (907) 343.7904 ONSITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW040131 PID Number. 051.792.23 rrevor Fairbanks Wastewater System: ®New ❑ Upgrade Aeeroaa: orge Place. Eagle River, AK 99577 ABSORPTION FIELD Pnarr: Nunbr a Bedoorm: 230-7348 3 17 Dep Trane ®shalbw TnrrJl O add ❑ Mq.ld O Oltarr LEGAL DESCRIPTION SO Ramp, Taat caller krn rlgaut grade: 0.6 GPD/Fe 5.5 Fl. Blorl: la: aubowbn: 2 19 Dptn m pW Oonrn darn nn7•lal Areae: Gravel depth benaelh plea: McKinley View 1.46 Ft. 4.02 Ft 70.eahtp: arae: Saawn: Fi added aeove mPnel Prada: Gravel Larpin: 2.4-2.19 Fl. 76 Ft. - Well: New [I Upgrade Gfve1"0'"' "r.nbwalnea: DlaWlc. heMaan ansa: 5.0 Ft. 2 10 FL claesrnomn (Pmate. A a. c): Taal Depth: Caead b: Tell absrpaun reel: Pa» MelerW: PUBLIC Ft. FL 760 Ft' D3034 & F810 Dnaer. Dale Drred: SMac Water Lowell; 1na1&Aar: Ora M Nod: FL Trevor Fairbanks• Owner 1011912003 Pran.l01: p s Ga l np lblpht Above Cr ; TANK GPM fl• FL SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other. oell lc Atisorption Lilt Holding u r"at r: - r: From Tank Field Station Tank Sewer Line Quality Products 1000 Gat. wait 200'+ 100'+ NA NA 25'+ McWel. Numb.ra ComPrurrnta: Steel 2 6,0a Wow 100•+ 100'+ NA NA LIFT STATION La Lin. 5'+ 81" NA NA ua' Gel. Foundation 5'+ 10'+ NA NA 1eep M •` 'u p at: -al.larm yh wr aaL r in. . twin Delo NA '50'� 7l" NA"" ''i NA ; - Pup Made a Mmol El«brael anPacar. Perrmned br n1uLa. •noneknown BENCH MARK "lot -tine waiver requested—see tittached letter' • Door sill tank Insulated S tank manufacturer approved per DSD rel 100 FL Engineer's Stamp %%%Il �P�ry OF At Gj ••a ef' i Inspections performed by: KND Enaineerina. Inc. Dates: 1St 6125104 r ,.� 2 nd6128104 so so ... .... .. . ... 3'° 4111105 9 t " •••• • .0 a" % �� Kennet (f Development Services Department Approval 1 if Reviewed and approved b Date: 23 cf 19Foa 0� �SIONA�+air (Rc. 17AU1 IVUI E: wu E;' I A'tZ@4L. f' T)Wkr SVM '60 -AS" Or 1c• B 04JXi--t, l-,WAI- \ rz ht oNE 7':n, vt A.Vy Pi2ujit QPP'+OelAI er..l�2 7+Vka C 'Q ur11:1yr . s?t>c�.. c'IS Wrr.t. ISEQdr /�N O"rS .>•E n•v0 ce¢r,irl;cArF 0* torr'icl rNS fA(19 T'ILYti AS—BUILT SYSTEM DETAILS/SITE PLAN McKINLEY VIEW ESTATES SUBDIVISION, BLOCK 2, LOT 19 Khlp LOT TH #97-1 1000 GAL. O / ASEPTIC TANK A—C=37' B—C=22.5' A—D=41' B—D=28' A—E=58.5' B—E=75' A—F=60' B—F=76' A—G=87' B—G=55.5' ��o� /7//,// 77, �g 4 Co 4Co ti -, low. . OF L`��5 *4/9zx *+l XENN1=y,. D 711 1 y.'17 \ �PE391 Permit SW040131 PID#051-792-23 20 APPROX. A LOC.OF WATER / CO 4 D C 3 Bdrm House Deck CO B \eM KE 0 ` � `DriVewoy' ••• ` LOT.: A,• Op OT 18sGALE/1•�4 CLEANOUT MONITOR TUBE FINAL GRADE 98.31 94.6 FROM 94.6 SEPTIC TANK SEWER ROCK d 90.6 TO 76' DRAINFIELD 62.1 BOH PREPARED FOR: DENNIS & LINDA FAIRBANKS 10226 GEORGE PLACE EAGLE RIVER. AK 99577 907-694-4587 FIELD BOWLS CMTED. BWNDMr.. _ DRAW rsm STANINC: DNEOtED: KMD '"' SEWARD DATE: 04/199 DM FY v CMD: NW1459 ACA FU: 04020 ASBAwc i1°D N' 04-020 SCALE: NTS ABBREVIATIONS BOH m BOTTOM OF TESTHOLE CO CLEANOUT MT = MONITORING TUBE NTS NOT TO SCALE END ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)868-3791/FAX (907)868-3793 1000 Gj SEPTIC o low. . OF L`��5 *4/9zx *+l XENN1=y,. D 711 1 y.'17 \ �PE391 Permit SW040131 PID#051-792-23 20 APPROX. A LOC.OF WATER / CO 4 D C 3 Bdrm House Deck CO B \eM KE 0 ` � `DriVewoy' ••• ` LOT.: A,• Op OT 18sGALE/1•�4 CLEANOUT MONITOR TUBE FINAL GRADE 98.31 94.6 FROM 94.6 SEPTIC TANK SEWER ROCK d 90.6 TO 76' DRAINFIELD 62.1 BOH PREPARED FOR: DENNIS & LINDA FAIRBANKS 10226 GEORGE PLACE EAGLE RIVER. AK 99577 907-694-4587 FIELD BOWLS CMTED. BWNDMr.. _ DRAW rsm STANINC: DNEOtED: KMD '"' SEWARD DATE: 04/199 DM FY v CMD: NW1459 ACA FU: 04020 ASBAwc i1°D N' 04-020 SCALE: NTS ABBREVIATIONS BOH m BOTTOM OF TESTHOLE CO CLEANOUT MT = MONITORING TUBE NTS NOT TO SCALE END ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)868-3791/FAX (907)868-3793 ASBUILT SEWARD &ASSOCIATES LAND SURVEYING 694-082 1 HEREBY CERTIFY -THAT 1 HAVE SURVEYED THE SCALE: � FOLLOWING DESCRIBED PROPERTY. /qs� � ire rii<wEfi,�rs'ra� <oriy e� s �E OF At AND THAT NO ENCROACHMENTS E)�ST EXCEPT AS DATE] INDICATED. IT IS THE RESPONSIBILITY OF THE r OWNER TO DETERMINE THE EXISTENCE OF ANY GRID EASEMENTS, COVENANTS, OR RESTRICTIONS "ox'-'9 "I WHICH DO NOT APPEAR ON THE RECORDED SUBDI- UNDER NO CIRCUMSTANCES SHOULD FB: Du"s Mark 3-ward / VISION PLAT. >'� ANY DATA HEREON BE USED FOR CONSTRUCTION /�I o9q;••. kS-6918`�.: �� OF FENCE LINES, OR FOR ESTABLISHING BOUND- C:ow ARY LINES. DRAWN bk t ��� Municipality of 114M HU170 • Anchorage, Alaska Yki l4lfirn0 • Telephone ('.N(7) 33.4 8'101 •Pae (fXM M -82(X) 4700 Brugaw Siam • Anchorage, Alaska 917517 dlayor Mark Begich alma a l.org I3uilding Safety Di-Osion April 28, 2005 Kenneth hi. Duffus, P.E. KND Engineering, Inc 20441 Ptarmigan Blvd. Eagle River, AK 99577 Subject: Waiver Request for Mckinley View Block 2 Lot 19 Waiver Request WR#: 050023 Parcel ID # 051-792-23 IIA/Permit # Dear Kenneth M. Duffus, P.E.: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to property line has been approved. The approved separation distance is 8.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, rE00ngi0itneer On -Site Water & Wastewater Program C0111 In till ity, Security, Prosperity Municipality of Anchorage Development Services Department • ++ Building Safcty Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchoragc.ak.us (907)343-7904 Waiver Review Worksheet WR#:050023 PID#:051-792-23 HA/Permit# •SW040131 Date Received: April 28, 2005 Legal Description: Mekinley View Block 2 Lot 19 Engineer. Kenneth M. Duffus, P.E. KND Engineering, Inc 20441 Ptarmigan Blvd. Eagle River, AK 99577 Applicant: Trevor Fairbanks Waiver Requested: 8' Lot Line Waiver Criteria: Geology A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: Waiver is Granted: X Waiver is not Granted: List Conditions or Reasons for above: Points: Date: 4/28/05 By: Joe Goodall Name of Reviewer Rec#: 88789 Amount: $1M Date Paid: 41281200s 1K V D ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER. AK 99577-8736 11 / FAX (907)696-8111 April 19, 2005 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 RE: SEWER PERMIT/ LOT LINE WAIVER — McKinley View, B2, L19 Gentlemen: During the as -built process we encountered a problem with the system being in dose proximity to the lot line. The attached survey verifies that the system was constructed within 10 feet of the property line. The system is still located within the testhole radius and we do not expect there to be any adverse effect on adjacent lots by the location of this system. We are therefore requesting a waiver to 8 feet to lot line at this time. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, KND Engineering, Inc. Attachments: Survey Inspection Report Septic System As -built A -7s 4 -s7-Or 66-7g94;;A� C04Municipality ofAnchorager.o. t�,c tal u�l) • anchorage. ,vnsk, <ra,to.t •Tele ,hone ('J07) 32 S t3 A)1 .' 1 fuc (J117J a4.4tS;.IN1 4" 47W Bragaw Strecl • .V,clwrage, .Uusku M507 mm munLorg Mayor Mark Begich Bullcting Safety Division 18 April 05 Linda Fairbanks 10226 George Place Eagle River, AK 99577 Subject: Expired On -Site Water and/or Wastewater Permit. Permit Number: S W040131 Legal Description: McKinley View Block 2 Lot 19 Dear Linda Fairbanks: An On -Site Water/Wastewater Permit, number S W040131 issued by this office for a single-family system, expires on 19 May 05. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. When applying for a new permit, the fees are: $460.00 for a wastewater permit and $175.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincerely, ell' WRothDarnel J. Manager On -Site Water and Wastewater Program Enc: Copy of permit Community, Security, Prosperity &112916y- o gay MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: May 19, 2004 Expiration Date: May 19, 2005 Permit Number: SW040131 Parcel ID: 051-792-23 Legal Description:OMaMey View Block 2 Lot 19 Design Engineer: 0070 KND Engineering Site Address: 21344 Baron Or Owner Name: Linda Fairbanks Lot Size: 20046 SO. FT. Owner Address: 10226 George Place Total Bedrooms: 3 Permit Bedrooms: 3 Eagle River. A 99577 - This permit is for the construction of: 0 Disposal Field [?] Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be In accordance with: 1. The attached approved design. 2. Ail requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. NOTE: SIz110q —> DEs,9n/ Rcvisto^) a,E 40 F/lovlc(�v4TF✓Z CM)E PIEA5C- 5re- L ETTsR, jOAf-rc% S`j7_,j0-f7 FRo^1 Icn/p. Received By: Date: 5/-? G y Issued By. 4� Date: S (y /0 -f K N D ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER. AK 99577-8' /FAX May 21, 2004 Municipality of Anchorage Development Services Department On -Site Water &Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: New sewer permit—McKinley View Estates, B2, L19 Gentlemen: During groundwater monitoring this week at the above subject property, it was discovered that TH#97-1 was dry, but TH#97-2 had groundwater at 10' below existing grade. Subsequently we have modified the 3 -bedroom design to a 5 -wide shallow trench as follows: 1. 450 GPD/0.6 GPD/SF = 750 SF 2. 750 SF/5'W (.50) RF = 75'L 3. Use 1 trench 75'L x 5'W x 4'D 4. Total depth of system is 5.5' from original grade. 5. Insulate trench with 2" HD burial foam if <3' cover. All other design details will remain the same as previously submitted. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, KHD Engineering, Inc. )enneth uffus, P.E. : Municipality of Anchorage • -� Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. - OY 1- :7-7 Z - 7, 3 Permit Number SW Property owner(s) Linda Fairbanks Day phone 694-4587 Mailing address (1) 10226 Gpnrge_Place, Fagle Rives AK 49577 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd) McKinley View Fstateq, 7. L1g Legal description (Section, Township & Range) Lot Size 04(0 Acres �e T THIS APPLICATION IS FOR: Number of Bedrooms -1 Sewer Only ® Well Only Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. of property owner or authorized agent) Permit Fees: Date of Payment: Jy,Ob Waiver Fees: Date of Payment: Receipt Number: Receipt Number: (Rev. 12(00) J11K D ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-8111 May 12, 2004 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: New sewer permit — McKinley View Estates, B2, L19 Gentlemen: The owner has requested we proceed forward to obtain a septic permit on the subject lot. On May 16, 1997 two test holes were performed for the proposed system. The results of these tests are attached. The general slope of this lot is from west to east at a grade of approximately 2-5%. We have designed our system utilizing the existing testholes that were excavated for the proposed 3 -bedroom house. The lot will be served by public water. We propose to install one trench. Water was not encountered during the excavation or during monitoring. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111 /FAX 696-8111. Respectfully submitted, MID Engineering, Inc. Kenneth M. Duffus, P. . Attachments: On -Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test Contractor/ Owner Specs WASTEWATER DISPOSAL SYSTEM/SITE PLAN MCKINLEY VIEW ESTATES SUBDIVISION, BLOCK 2, LOT 19 LOT 8 LOT 7 j�0 % TN 7-z % i /97-1. O �Pn ALL LOTS SERVED 9Y COIUI.NTY WATER SYSTEM. NO SEPTIC SYSTEMS MMM 2OD' Or PROPOSED SELL. EXCEPT AS NOTED. NO PRIVATE OR PUBUC SELLS W NR1 2W OF PROPOSED SYSTFN EXCEPT AS NOTED. ��.......... `9s 1 jol TE 197-1 PR[YOSED PF Au Wvtn LOT 18 LOT 17 r LOT 17 DESIGN CRITERIA 1. 3 BEDROOMS X 150 GAL/DAY/BEDROOM - 450 GPD 2. SOILS RATING: 20 MIN/INCH - APPL RATE 0.6 GPO/SF 3. 450 GPD/0.6 GPD/SF - 750 SF 4. 750 SF /(2' x 5') - 751 5. MIN. DESIGN SIZE - 1TRENCH - 75' LONG x 2' WIDE It 5' DEEP 6. DEPTH OF GRAVEL BELOW PIPE IS 5'. 7. TOTAL DEPTH OF SYSTEM IS 7.0' FROM ORIGINAL GRADE. NOTES: 1. TIE INTO TRENCH AT ENDPOINT. 2. INSTALL 1000 GALLON SEPTIC TANK. INSULATE TANK IF <4' COVER. 3. INSULATE TRENCH WITH 2' HO BURIAL FOAM IF <3' COVER. 4. CONTRACTOR WILL ENSURE MAXIMUM 2% SLOPE INTO SEPTIC TANK. 5. CONTRACTOR TO INSTALL SPLITTER. PREPARED FOR: KND ENGINEERING DENNIS & LINDA FAIRBANKS 20441 PTARMIGAN BLVD :.•` 10226 GEORGE PLACE IV EAGLE RIVER, A(9 99577 �,. EAGLE RIVER, AK 99577 (907)696-6111/Fox (07)696-8111 9 907-694-4587 DATE- 6/10/97 DRANING SCALE: 1' 1O0' 97044 -St WASTEWATER DISPOSAL SYSTEM/SITE PLAN McKINLEY VIEW ESTATES SUBDIVISION, BLOCK 2, LOT 19 /l Q� PROPOSED SYSTEM p GO LOT 20 ; r' TH 97-2.j, 19 CO T H #97-1 co om�m co �co Co CO CO ROPOS !' ATER LIN£ iYX � ..............` -44 Cr /AMLU r UK: DENNIS do LINDA FAIRBANKS 10226 GEORGE PLACE EAGLE RIVER. AK 99577 907-694-4587 KND ENGINEERING 20441 PTARMIGAN BLVD EAGLE RIVER, AK, 99577 (907)696-6111/FGx (907)696-8111 D/97 DRAWING :ALE: 1* — 50' 97044-51 P�E� OF �A TND ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 Kenneth At. D, Cc 7175/ SOILS PERCOLATION TEST'•...____-. Performed for: Dennis Fairbanks Date Performed: 5/16/�9�� Project: McKinley View Estates B2, L19 TEST HOLE 9 97-2 Depth (Feet) SEE ATTACHED SITE PLA 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- Org/OL - brown, sandy gravelly silt w/organics, moist SP/sm -silt & density increasing w/ depth - occ. cobbles B.O.H. HOLE PRESOAKED PRIOR TO TEST N FOR HOLE LOCATION Was Groundwater encountered? NO Whatdepth? NA Depth to water after monitoring? NO Date? 5/22/97 Reading Date Gross Time Net Time Depth to Water Net Drop 1 5/16/97 1:00 - 7" - 2 1:30 30 min 58/16" 18/16" 3 1:31 - 7" - 4 2:01 30 min 57/16" 19/16- 5 2:02 - 7" - 6 2:32 30 min 58/16" 18/16" Water Added Percolation Rate 20 (min/ in) Perc Hole Diameter 6„ Test Run Between 4 feet and r feet 1, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. KIK D ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 SOILS PERCOLATION TEST OF A4,1%11 Kenneth M CE 71 Performed for: Dennis Fairbanks Date Performed: 5/16/1997 Project: McKinley View Estates B2, L19 TEST HOLE # 97-1 Depth (Feet) SEE ATTACH I- 2- 3- 4- 5- 6- 7- 8- 9- 1G- 11- 12- 13- 14- 15- 16- 17- 18- 19- Org/OL — brown, sandy gravelly silt w/organics, moist SM/SP—cobbles, silt 6r density increasing w/ depth B.O.H. HOLE PRESOAKED 20- PRIOR TO TEST ED SITE PLAN FOR HOLE LOCATION Was Groundwater encountered? NO What depth? NA Depth to water after monitoring? NO Date? 5/22/97 Reading Date Gross Time Net Time Depth to Water Net Drop 1 5/16/97 1:00 7" _ 2 1:30 30 min 411/16" 2 5/16" 3 1:31 7" - 4 2:01 30 min 412/16" 2 4/16" 5 2:02 7" _ 6 2:32 30 min 412/16" 2 4/16" ' Water Added Percolation Rate 13.3 (min/ in) Pere Bole Diameter 6" Test Run Between 4 feet and _5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. TK D ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 696-6111 / FAX (907) 696-8111 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES AND MATERIAL SPECIFICATIONS LEGAL DESCRIPTION: McKinley View Estates, Block 2, Lot 19 GENERAL: 1. The scope of this project includes the installation of a septic tank and/or drainfield to serve a single-famil residence on the referenced property as delineated on the attached Municipality of Anchorage MOA) permit and site plan. 2. Construction shall be in accordance with the approved site plan and design drawings; MOA permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. KND Engineering Inc (KND) assumes no responsibility of the accuraty of the as -built survey provided by the owner or owner's representative. 4. The owner or contractor is responsible to notify the engineer of any discrepancies noted on the design plans or drawings prior to commencing work. These discrepancies could be, but not limited to, possible encroachments, surface water, varying soils, unplatted easements, types or use of dwellings on or adjacent to property, nearby public wells, etc. 5. The contractor shall be responsible for locating any necessary underground utilities, easements, property lines and surface water. The owner and/or contractor shall ensure, if deemed appropriate, that a registered land surveyor prior to construction flags all setbacks. 6. The contractor shall be responsible for verifying all pertinent separation distances and component layout. 7. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. 8. The MOA Development Services Department On -Site Water & Wastewater Program must certify contractors installing wastewater disposal systems. Owners installing their own systems must also receive prior approval from said MOA Department. SEPTIC TANK / HOLDING TANK / LIFT STATION INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded with proper material and compacting to prevent damaging, settling or shifting of the tank. . 3. All standpipes on the septic tank shall extend a minimum of 12 inches above the final grade. 4. Septic tanks installed with less than 4 foot of cover shall be insulated. The contractor will ensure that the fill over the tank does not exceed the burial depth rating. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 feet from the tank. The second cleanout, in line, shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. r."e i ,.r a Reference: McKinley Vw. Est. B2, L19 Date: 05/13/04 Page: 2 of 3 7. All H.D.P.E. tanks shall have a vertical length of 4 -inch perforated drainpipe besides the tank extending to the bottom of the tank to above grade to monitor ground water. 8. All tanks shall be anchored when there is not enough adequate soil cover to resist buoyancy forces in high -groundwater areas. 9. All holding tanks and lift stations shall have an audible and visual alarm inside the residence. 10. All lift stations shall be wired in compliance with the Uniform Electrical Code and all MOA guidelines. 11. The contractor shall remove the old tank, or abandon it in compliance with the Uniform Plumbing Code. The contractor is solely responsible for the abandonment procedure. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavaction become smeared, they must be raked or scratched (roughed -up) before gravel (sewer rock) placement. 2. Once the sewer rock is installed, the distribution pipe is installed level with the perforations facing downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitoring tubes shall be four- (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. 6. All advanced technology waste water disposal systems (Advantex, Biocycle, Intermittent Dosing Sand Filter, etc...) shall be constructed, installed, maintained and monitored per manufacturer's specifications and MOA requirements. MINIMUM MATERIAL SPECIFICATIONS: 1. A MOA approved septic tank manufacturer must construct any septic tank proposed for installation. 2. The following pipe materials are MOA approved for use in septic system installations: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final Icachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. If deemed necessary, a sieve analysis should be performed. 7. When sand is being used as a filter material, its gradation specification must conform to current MOA or DEC requirements. Reference: McKinley Vw. Est. B2, L19 Date: 05/13/04 Page: 3 of 3 INSPECTIONS: Typically there will be three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the sewer rock, distribution lines, standpipes, and cleanouts, but before the placement of the silt barrier, insulation, or any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required, especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. The inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's activities. The owner shall contract with the contractor to perform the work outlined in these specifications and attached plans and in accordance with the attached MOA permit. All materials, components, and construction practices shall comply with the MOA's and the State of Alaska's latest ordinances, regulations, or policies regarding wells and septic systems. The failure of the inspecting engineer to notice a material or construction non-compliance does not relieve the contractor of his/her responsibility to correct such deficiency. There will be no contractual arrangement existing between the contractor and KND Engineering, Inc. KND shall be the owner's representative and will inspect the work as stated above to document the contractor's activities. Final acceptance of the contractors work rests with the owner and the MOA. KND shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. KND's inspecting engineer will not be responsible for the construction means, methods, and techniques, sequence, procedures or the safety precautions incident to this project. BY PROCEEDING FORWARD WITH THE INSTALLATION OF THE WATER AND/OR WASTEWATER SYSTEM (S), THE PROPERTY OWNER, CONTRACTOR, AND WELL DRILLER ACKNOWLEDGES HAVING READ AND ACCEPTED THESE SPECIFICATIONS. Parcel I.D. 051-792-23 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Expiration Date: 3 _ r 13 / J lfi K' 3 Municipality of Anchorage On -Site Water and Wastewater Program s (907)343-7904 snr Individual Well Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Expiration Date: 3 _ r 13 / J lfi K' 3 M Complete legal description C Inley vleW, BIOCK 2, Lot 19 Location (site address) 21344 Baron Dr. Current Property owner(s) Diane 8t Denver Williams Mailing address PO BOX 672078 Real Estate Agent 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone Day phone 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System Q Public Sewer ❑ WaiverNariance request Received by: � �a�o✓�.� Date: 51c, /, COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 14go �Waiver Fee $ Date of Payment 3 l Date of Payment Receipt Number ai aa Receipt Number COSA # o5C[ 3109 a Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Pannone Engineering Services LLC Address P.O. Box 100217, Anchorage Ak. 9&10 Engineer's Printed Name Steven R Pannone 6. DSD SIGNATURE _V_�_ System #1 Approved for bedrooms System #2 Approved for bedrooms Disapproved Phone (907) 272-8218 Date / . ,�f Conditional approval for bedrooms, with the following stipulations: By: Original Certificate Date: 3 -c�7"/-3 Theunic� t of P,g orage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered In the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory r. Septic System Advisory Arsenic Advisory' Well Flow Advisory Other COSA blue sheet r . c If more than 1 septic system is on the lot: COSA Checklist # 1 of 1 Structure served by this system 1 Certificate of On -Site Systems Approval Checklist Legal Description: McKinley View, Block 2, Lot 19 A. WELL DATA Well type Class 'A' Total depth Parcel ID: 051-792-23 If A, B. or C provide PWSID # 210697 Well Log (Y/N) Sanitary seal (Y/N) Cased to ft. LOG Date of test Static water level ft. Well production g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: B. SEPTIC/HOLDING TANK DATA Wires properly protected (Y/N) Casing height (above ground) in. AT INSPECTION ft. Collected by: �- Tank Type/Material Septic/Steel Date installed 10/19/03 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (YIN) N Date of pumping 9/27/2012 Pumper Sanitary Pumpers C. ABSORPTION FIELD DATA Date installed 10/19/03 Soil rating (g.p.d./f:2 or fe/bdrm) 0.6 GPD/sqft System type Shallow Trench Length 76 ft. Width 5.0 ft. Gravel below pipe 4.02 ft. Total depth 7.5 ft. Eff, absorption area 760 ft2 Monitoring tube Y Depression over field N Date of adequacy test 3/18/13 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test 12 in. Water added 466 gal. New depth 16 in. Elapsed Time: 130 min. Final fluid depth 16 in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date 9 D. LIFT STATION "Pump on" level at Datum Size in gallons in. "Pump E. SEPARATION DISTANCES ON LOT TO: Septic tank/lift sYatton- Absorption field on lot Public sewer main Sewer /septic service line Animal containment areas Cycles tested Manhole/Access (Y/N) _ High water alarm level at Meets alarm & circuit On adjacent lots On adjacent lots manhole/cleanout Holding tank Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5+ Water main 10+ Water service line 10+ Wells on adjacent lots 200+ ABSORPTION FIELD ON LOT TO: Property line 8+ Building foundation 10+ Water Service line 10+ Surface water 100+ Curtain drain 50+ Wells on adjacent lots 200+ F. COMMENTS G. ENGINEER'S CERTIFICATION 1 certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Steven R. Pannone Date / 36 -S24d COSA brown sheet 10-10-12.doc Absorption field 5+ Surface water 100+ Water main 10+ Driveway, parking/vehicle storage 110+ in.