Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
QUIET WOODS LT 6D
Quiet Woods Lot 60 #050-281-50 ^� afity -: 1x -s SxJ�'Te� ©1 POUCH 6-650 ANCHORAGE. Al A ;'!:A (907)264-4111 IOVv "' CS f1.11 ':11 M 'Aft H.11 N Ui w "111.,.'i! NVIiRONbRN1 At. 1`R(11 f_C71(li ,Permit #: 820399 January 31, 1983 TO: Permit Applicant Subject: Lot 6D Block 8 Quiet Woods Subdivision A permit issued by this department for an individual well and/or on-site sewer system has expired as of December 31, 1982. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal Ordinance. If you have drilled the well, a well log needs to be sent to this department for documentation of the installation date and to close the permit. If a private engineer inspected the installation of the on-site sewer system, please have them send us the as-builts for our files and documentation. If there are any further questions, please call this office at 264-4720. Sincerel2"'g- Robert QC. Pratt, R.S. Acting Program Manager Sewer and Water Program RCP/ljw enc: Copy of Permit SWP/057 hl L-1 r --d I k_ I F• 1=1 L_ I _r '-r' LD F Fl Y-4 r_ H rr f_: R :a E DEF'ARTHENT QF HEALTH AND Ef.4VIknpJplEr!TRL ez�RC,TECTIOPJ 82 �� STREET, ANCHORAG-E. FERMIT NO. ( 820399 ) F.=PLICANT HARRY A MACKEY LOCATION WILDWOOD ST EP. LEGAL L6DB8 QUIETWOODS 254-4720 - t4EE: L_L F EFRr•1 I T SRN2EOX 6355 CHUGIAK 688-2813 LOT SIZE 13060 SOURRE FEET MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTANCE FROM R PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. WELL LOGS ARE REOUIPED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F'EFz-MIT EXF' I ME:- GE0E:ME:ER = 1, s n --4:E* I CERTIFY THAT 1: I AM FAMILIAR WITH THE REGUIP.EMENTS FOR ON-SITE SEWERS AND I -JELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYST 1 IN ACCORDANCE WITH THE CODES. SIGNED:- APPLICANT HARRY R MR KEY 1 ISSUED B''--- -- ------ n -------DATE ------ �i-a-c�-OL V4.0 APPLI''%NT FILLS OUT UPPER HAS' ONLY Time Property Owner /i / .Y.�T ,C r Date Date Mailing Addreu / Date Inspector Zip Code Q Inspector Buyer Coe Y Inspector Field Notes: Address Zip Code ( MUNICIPALITY OF ANCHORAGE DEPT1 O.V HSR & ENVIROV,A:N PROTECTION PROTECTION A�- /7 Lending Institution 'I"-' Gk �,'w ," Y MT,� Phone Address I: r r -4W 'CONDI ONS OF PROVAL Zip Code Realty Co. & Agent � , L c � K� 5 BY: ` ^Phoonneeii-7 �s� / Address - Well To Absorption Area Zip Code 4` /" / "-- Legal Description� Well to Tank Street Location Type of esidence Ingle Family ❑ Multiple Family No. of Bedroom ❑ Other Water Supply . Individual ATTACH WELL LOG. A well log Is required for all wells drilled since June 1975. ^�. ❑ Community \ For wells trilled prior to that date, give well depth (attach log If available). ❑ Public Utility Sewer Disposal �- ❑ I�lvlduat Year individual Installed: V Public Utility When Connected to Public Utility: ❑ Holding Tank t NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 10 rr,00 ,-r Time Time Time Time Date Date Date Date Inspector Inspector Inspector Inspector Field Notes: I ( MUNICIPALITY OF ANCHORAGE DEPT1 O.V HSR & ENVIROV,A:N PROTECTION PROTECTION JUN 23lvz; ( PROVED BEDROOM$ ( ) DISAPPROVED I: r r -4W 'CONDI ONS OF PROVAL ( ) CONDITIONAL APPROVAL- DATE BY: Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received Septic Tank Size Well to Tank Municipality of Anchorage • On-Site Water and Wastewater Program (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 050-281-50 Expiration Date: 1. GENERAL INFORMATION Complete legal description Quiet Woods Lot 6D Location (site address) 10022 Wildwood St Current Property owner(s) Lewis Day phone 414-8563 Mailing address Same Real Estate Agent Crystal Chambers Day ••••- 414-8563 v�6189 1077 2. TYPE OF DWELLING: � '' % t Single Family (w/wo ADU) ❑ Duplex ti ❑ Multiple Dwellings (Single Family and/or Duplex) x!! 0168 ' 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual ❑ Individual Water Storage ❑ Holding Tank ❑ Community Class C Well Cl Community ❑ Public Water System ❑ Public Sewer Received 1:* . - 4‹ Date: / Z/z/// COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ Jr' 2- ' Date: Date of Payment 24 1 Q IIS Date of Payment Receipt Number Oq9-tib Receipt Number COSA# ©5C l$1645 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm NorthRim Engineering Phone 694-7028 Address PO Box 770724,Eagle River Engineer's Printed Name Steve Eng Date 12/19/2018 6. DSD SIGNATURE System #1 Approved for bedrooms. System #2 Approved for bedrooms. Disapproved. )' r I `^ u' Conditional approval for bedrooms, with the following stipulation:E,,.;.•,�� ' . • ON-SITE 1., s WATER AND WASTEWATER c, PROGRAM g '!kr-� R\ F: I't'�`� By. - Original Certificate Date: I'2z1 -12 The Municipality of Anchorage Devlopment Services Division(DSD)Issues Certificates of On-Site Systems Approval(COSA)based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate;Acvisory. Septic System Advisory Arsejic,Adv spry r Well Flow Advisory Other COSA blue sheel_9.1-12.doc `"' If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On .Site Systems Approval Checklist Legal Description: GdLIe_f Oood.S L' 6 t Parcel ID:0sazgI .SG A. WELL DATA Well type P If A, B, or C provide PWSID# Well Log (Y/N) A] Date completed /?02 Sanitary seal (Y/N) y Wires properly protected (Y/N) y Total depth 0 ft. Cased to 8)0 ft. Casing height(above ground)/Z4— in. FROM WELL LOG AT INSPECTION Date of test. /O//t/i, Static water level — ft. 3. 5 ft. Well production — g.p.m. S'f' g.p.m. WATER SAMPLE RESULTS: Coliform D colonies/100 mL Nitrate e.32 mg/L Arsenic `J ug/L Date of sample: l0/0 te Collected by: A40( Lu,i J B. SEPTIC/HOLDING TANK DATA PUaLt Tank Type/Material Date installed Tank size gal. Number of Compartments Cleanouts (Y/N) Foundation cleanout(Y/N) Depression over tank(Y/N) High water alarm (Y/N) Date of pumping Pumper C. ABSORPTION FIELD DATA Pt 6/4 C.— Date installed Soil rating (g.p.d./ft2 or ft2/bdrm) System type Length ft. Width ft. Gravel below pipe ft. Total depth ft. Eff. absorption area ft2 Monitoring tube Depression over field Date of adequacy test Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: Min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION A/4 Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off" level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot AIA On adjacent lots /OO (q- Absorption field on lot N On adjacent lots /Q Q t t / Public sewer main 7 5 r /Public sewer manhole/cleanout . J(14-- Sewer -Sewer/septic service line Z5 ,+. Holding tank /Q6 `.- i Animal containment areas SO t Manure/animal excrete storage areas /QG1.f._ SEPTIC/HOLDING TANK ON LOT TO: P 0Bc-t C-- Building foundation Property line — Absorption field Water main Water service line -- Surface water Wells on adjacent lots ABSORPTION FIELD ON LOT TO: PUBLIC--• Property line Building foundation Water main Water Service line Surface water Driveway, parking/vehicle storage Curtain drain Wells on adjacent lots F. COMMENTS G. ENGINEER'S CERTIFICATION M'. I certify that I have determined through field inspections and "E 1 review of Municipal records that the above systems are in Lf ' { ` ., conformance with MOA COSA guidelin s in effect on this date. ijg r:r.g:.:3 1::;"2.;;1 * 4 e� Engineer's Printed Name - ' t ' s .s a 60 Date 4,0 e � ; „�o`. � 4 1 w 4� w�a�® ��. ‘ COSA yellow sheet_2-6-15.doc MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT • ( '� 907-343-7904 On-Site Water and Wastewater Section `'i l` Fax: 343-7997 www.muni.org/onsite Nitrate Advisory' Certificate of On-Site Systems Approval # 0SC181645 Subdivision: Quiet Woods, Lot: 6D A water sample revealed a nitrate concentration of 8.32 milligrams per liter (mg/L). The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On-Site Systems Approval. Mailing Address: P.0. Box 196650*Anchorage,Alaska 99519-6650 *www.muni.org • Nitrate Fact Sheet From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids,and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. Mailing Address: P.O.Box 196650*Anchorage,Alaska 99519-6650 *www.muni.org Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program y 4700 Bragaw Street �q P.O. Box 196650 pct'' Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcell.D.D50~�$j-.�i 0 1. GENERAL INFORMATION COSA # 0 7-0 2 RS Expiration Date: I1 — I — O�L Complete legal description Q vre!!I� Oa o cO-K La7c 6D Location (site address) /06 Z Z Current Property owners) Mailing address Lending agency Mailing address Real Estate Agent Mailing Address Urdess otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: _3 3. TYPE OF WATER SUPPLY: Individual Well 91 Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ Day phone Day phone 3 73- S'0'00 TYPE OF WASTEWATER DISPOSAL: Individual On-site ❑ Individual Holding Tank ❑ Community On-site ❑ Public Sewer The Municipality of Anchorage Development Services Department (DSD) issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered In the State of Alaska. Certificates of Onsite Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSO also Issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm _J�L�( ligµ 65_a a . Phone -tC%_! 7C67 Address Pa SnX Tia -7,2c{ Engineer's Printed Name ZSTe✓F C Date 7/3110 r' fo 'a of ste"M W. ins 5. DSD SIGNATURE FE 6256 .•1 Approved forbedrooms. t,!\q`�11 Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By 12F Original Certificate Date: " G (Rev. l lm) Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw, Street P.O. Box 198650 Anchorage, AK 99519-6850 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Q v JQ f "As, L ef- Ch Parcel I D:0., "o - a 81-5 O A. WELL DATA Well type __P_ If A, B, or C provide PWSID # _ Date completed IfooZ Sanitary seal (YIN) Total depth fu fft ��fiCased to eo ft. f WP5AVROMWELLC OG Date of test Non e— Static water level Well production WATER SAMPLE RESULTS: Coliform _Q_colonies/100 mL Arsenic: ZJ_2 moll B. SEPTIC/HOLDING TANK DATA Tank Type/Material Tank size Foundation clean Date of aumoi (YIN) ft. g.p.m. Nitrate I" mg/L Dale of sample: Z �6�07 PUBUX SEvf44 Number of Compartments Depression over tank YIN) Pumper C. ABSORPTION FIELD DATA PO&(c S19wEe. Well Log (YIN) A Wires properly protected (YM) Casing height (above ground) in.4 AT INSPECTION 5. g.p.m. Other bacteria O colonies/100 mL Collected by. Date installed Cleanouts (YIN) High water alarm Date installed rating (g.p.d./ft2 or ft2/bdrm) System type Length ft. Width ft. Gravel below pipe ft. Total depth _ ft. E . absorption area _ftp Mondorin ube _ Depression over geld Date of adequacy test Results (Pass/Fail) For bedrooms Fluid depth in absorpti field before test _ in. Wa r added_ gal. ew depth_ in. Elapsed Time: in. Final fluid depth _ in. Absorption rate > g-p.d. Any rejuvenation eatment (past 12 mo.) (YIN & type) If give date D. LIFTSTATION PUaL(L Date installed Size in gallons Manhole/Access (YIN) 'Pump on' level at in. 'Pump off" level atin. High water alarm le I at in. Datum Cycles tested Meets alarm & ci t requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAift station on lot T - Absorption field on lot Public sewer maint- r Sewer /septic service line Z S f Animal containment areas On adjacent lots /QO r f On adjacent lots /do r'r Public sewer manhole/cleanout Holding tank ly� Manurelanimal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: ?aatL Se2-i4E,,P- Building foundation — Property line — Absorption field — Water main Wells on adjacent lots Water service line Surface water SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: #00B4tc. SE..uGoL Property line Building foundation Water main Water Service line Surface water Driveway. parking/vehicle storage Curtain drain F. COMMENTS G. ENGINEER'S CERTIFICATION Wells on adjacent lots •fr,'(:. ., C2 i;• I certify that I have determined through field inspections and P 49 Tot • •:. i review of Municipal records that the above systems are in , p conformance with MOA COSA guidelines in effect on this date. f f ...... Engineer's Printed Name S�Et/GS a�@ sl PE 6156 Date -7 7 T ��`l� �pRGF�y;lri•' COSA Fee $ 7' G 0 + % Rue L� Waiver Fee $ Date of Payment 6 - Dale of Payment Receipt Number `3 L / Receipt Number (Rev. 11/05) Municipality of Anchorage • "' Development Services Department j Building Safety Division s• srr - On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # 070288 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Lot 6D of Quiet Woods subdivision. This inspection revealed a nitrate concentration of 6.18 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. Analytica International, Inc. 4307 Arctic Blvd. Anchorage, AK 99503 Phone: 907-258-2155 Fax: 907-258-6634 ANALYPICA GROUP Northrim Eng Report Date: 7/30/2007 Attn: Steve Eng Receipt Date: 7/1612007 17237 Hear Paw Circle Sample Date: 7/1612007 Eagle River, AK 99577 Sample Time: 9:00:OOAM 907-694-7028 Collected By: TEng Fax: 907-694-7026 Flag Definitions: MRL = Method Reporting Limit Client Sample ID: MCL = Maximum Contaminant Limit Sampling Location: 10022 Wildwood St. B = Present also in Method Blank Client Project: Northrim Eng If = Exceeds Regulatory Limit Sample Matrix: Aqueous M = Matrix Interference COC #: J = Estimated Value PWS#: D = Lost to Dilution Residual Chlorine: •* = RL higher than hICL; target not detected Comments: TNC = Too Numerous to Count - result rejected CF = Confluent Growth - result rejected TCNG = Turbid Culture No Growth - rejected Lab#: A0707179-0IA Analysis Method Prep Prep Analysis Parameter Result Units Flags AIRL MCL Method Date Date Analyst 92228 (Aqueous) - Membrane Filtration hIF lest was conducted by: Analytica -Anchorage Bacteria, Other <MRL CFU/IOOmL 1.0 Total Coliform <MRL CFU/IOOmL 1.0 Lab#: A0707179-0IB hIIM IIti&HMiilItil711 7/1612007 7/16/2007 PL Analysis Method Prep Prep Analysis Parameter Result Units Flags MRL MCL Method Date Date Analyst 4500-NO3E (Aqueous) - Nitrate Test was conducted by: Analytica - Anchorage Nitrate as N 6.18 mg/L 2.5 10 7/1712007 7/17/2007 AJ Lab#: A0707179 -OIC Analysis Method Pre Parameter Result Units Flat MRL MCL Method Prep Analysis C� Date Date Analyst 200.8/200.8 (Aqueous) - Family Well Water 1 Test was conducted by., Analytica - Thornton Arsenic 2.12 ug/L 0.15 10 200.8 7/2412007 7/2412007 KS Reported by: Claire Toon, Page 1 of 2 Laboratory Project Manager r 7-9�r I3[• $1 7- AS -BUILT 1 hereby certify that 1 have surveyed the following described property: L OT' 6 -P . S.ac.-•fr�., 1z,T/cFN,F'2wysMt CJt '�� Precinct,Alaska, AnchorageG`:' and that the imdo ed thereon property > ro A,,(".. ,' s n r '. a m ntssta arc iithin lines and not overlap or encroach on the property lying adjacent thereto, that •' ...- . t V no improvements on property lying ad'acent thereto encroach on the in and that t�ere premises question are no roadways, ..Y. ...... , �•:. transmission lines or other visible easements on said property except as indicated hereon. f-•/«'RGY.ti j.., r Robert C. Joh^,u. ; ..,, 4% Dated at Ea le River, Alaska gg J'VfV f6?�1 'ay 200 : NO. :.G.� '`•.,;,;,;,.+ S.. this of : ROBERT C. JOHNSON' O �Qtftprl ,1 ���"�' SCALE: Registered Land Surveyor No.00-LS 1 20 ` Bog 77-0456, Eagle River, Alaska 99577 Phone (9177) 694-2543 .