HomeMy WebLinkAboutEATON PARK LT 10Eaton Park Lot 10 #051-111-78 Municipality of Anchorage ' Development Services Department ' *` Building Safety Division On -Site Water and Wastewater Program. 4700 S. Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 Page of www.d.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Qa Permit Number. SW050129 PID Number' 4)54-492-R Nape LH Construction, Inc. Wastewater System: ❑r New ❑ Upgrade Ae * 12130 Regency Dr.; Eagle River, AK 99577 ABSORPTION FIELD (907) 522-1616 NM of Baepoae: 4 D DseP Tnaa:n ❑ Swlao T ww El ase ❑M..w ❑oee: LEGAL DESCRIPTION Sa Renp 0.7 T°I"DOM I°'eon" W,,, 6axA: La. 10 sueow.ereF,. Eaton Park opo FP Dspmn Pps laMan eom alpw pets 10.5 Grow agnewnn Py.: T ° 15N Rap 1 W S.a.n. 1 D 7.5 Ft. Fe aoasa asow orq M era,. 0.5 Grace L FI WA F,. 60 n. Well: ❑� New ❑Upgrade G'e"e :15 NwtoNci,ean ae YYa ee.wwl eea. Private C,nN,KJOan (Prnee. A, 9. C): Taal Depw:*2FL FI. Taal awapeon area. 4 4 Ft Pp. IAeerwl 222FL 900 Fe 4- PVC (ASTM D-3034) pis DrRea.: Sullivan Water Wells 3/1/0FL UnNow LH Construction, Dee hNMea. Inc. 1221/05 Ywq. 12 Pune Se aL a.GPM F,.FL TANK SEPARATION DISTANCES OSeptic []Holding❑S.T.E.P. ❑other; To Septic Absorption Lift Holding ubaNPavale M aaar b Fmm Tank Field Station Tank Sewer Line Anchorage Tank & Welding 1250 GM. Wed 109' 125' N/A N/A 90' McMe, Steel 2 sw�wee +150' +150' N/A N/A LIFT STATION La Lew 55' 45' N/A N/A s. N/A TzzeM ac4ae. FanWson 17' 35' N/A N/A 'Party an M.M a 'Pump olr Mve e. Hyn w.le eem e. Yt M h ca..lxa" N/A N/A N/A N/A MalaaMafel Ew inspx po,%i e f RenNa: Area not landscaped at the time of the as -built BENCH MARK survey. LouWn arp 0.emgan. East Side of East Garage Stab. awa"n. 100 FL Engineers Stamp r `!a - Inspections performed by: Russell Hepner, E.I.T.Dates: 1" 12/21/05 49- t' 1 2nd 3/16/06 Development Services Department Approval 11.,n V1. 1 lu.,rtt r,;? Reviewed and approved by: Date: '51,410b< . %P*- NO 9'7-E o ." ,� • •. f �`', SYMMETRIC ABOUT C.L 4' SWEEP CLEENOUTS I WITH CAPS. MONITOR TUBE 71 I FILTER FABRIC I 7.5' BUILDING T 1 FOUNDATION r 4' PERF. PIPE CO I _T I�, I SEPTIC ROCK 6- 1 I FILTER SAND BED 2' 20 NEW 1250 -GAL I 2COMPARTMENT STEEL SEPTIC 3 O TANK T4 5' 5 �2' BOTH ENDS No GW To 1T —1 1BED SECTION N.T.S r r Notes: I I I 1. No neighboring septic systems, wells, or I I I I bodies of water are located within 100' I I I of this proposed system. I I I 1.50 FT. TYPICAL 2. On -lot well is 100' from system. I I I I 3. All pipe is 4" PVC (ASTM D-3034) with 4" 6 I I perforated PVC used in the wide drainfield. I • 4' MONITOR TUBE. 4. No driveways on / over septic system. I I I I I I I I I I I I TEST PIT ...Oi. s A ,:Allan W. f„urfitt;w r CLEANOUTS �� sifNO 4977-E tTYPi 4' x 56' PERF. PIPES `:--. PROrEc5 LAID LEVEL 4 PIPES AT 4 -FT CENTERS. PLAN 15'x 60' BED NTS onsulting Engineers and eshng A. W. Murfitt Comp PLATE 138 L H Construction, Inc. Septic enus ay nc oragc, 51 Lot 10, Eaton Park Subdivision 907 345-2737 Fax: 907 345-3264 Peters Creek, AK Job No. 05-394.14 Date: 3/23/06 Drawn: RH 15' TELECOM k ELECTRIC EASEME� _REBECCA MLL CIRCLE — — CA 0 S 89'42'0414 2\3.00' _ _ _ _ _ rn 5.0' COVERED PORCH +I I91.3 I_.,�EPTIC CLEANOUTS K) TWO ORY M WOODS FWwE 4 Q� 59.5' RESIDENCE a m p0 44.0' of 2.0' X 5.3' CANT z 4 0 LOT 11 N 2.0' CANT 40 0 12.3' X 18.0' DECK m 2.0' X 44.0' CANT ou � u LOT 10 40,367 s.f. 15' TELECOM do ELECTRIC EASEMENT S 89'54'56W 203.00' UrVTA/N S11A9 PLOT PUN AS BUILT X SCALE1� ��R� In Proleet No. 05-096 Lang & Associates, Inc. 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 (907) 522-6476 Phone oppOp� Registered Land Surveyors (907) 522-4625 Fax k9langle0alaska.net / jelangis0atasko.net 0�O•F q 9soo 1 hereby certify that 1 have surveyed the following described property: pA\P Q LOT 10, EATON PARK SUBDIVISION (PUT No. 2005-52) 0 �: 49� Anchorage Recording District, Alaska, and that the Improvements situated thereon aro thereto, that Q no Improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible within the property Imes and do not encroach onto the property adjacent 'ETH .LAN easements on sold property except as Indicated hereon. Q � Dated this the i(o Day of G ��. (p'•. LS -5 02 . —, at Anchorage, Alaska Po4�p 3f w�oe.•'o M Is the responsibility of the owner to determine the existence of any easementsIONN- covenants, or restrictions which do not appear on the recorded subdivision plat., YLA-CE 2 Elevation based on assumed garage slab elevation of 100.00'. "Invert measured from top of stickup Stickup Invert" Cover Top of Pipe Elevation' Invert Ground Water Garage Slab 9.3' 15.5' 2 (ST) 100' 24.2' 1 (CO) 10.5" 59.5" 49" 100.33' 95.37' 99.45' N/A 2 (ST) 45.25" 154.75" 51.5" 103.01' 90.12' 99.24' 91.53' 3 (ST) 49" 155.25" 48.25" 103.18' 90.24' 99.10' 91.93' Tank Inlet 79.8' 90.1- 10 (CO) 94.37' 79.6' 91.0' Tank Outlet 94.32' 4 (CO) 56" 125" 69" 104.42' 94.00' 99.75' NIA 5 (CO) 45" 116.25" 71.25" 103.68' 93.99' 99.93' NIA 6 (MT) 24" 150.5" 126.5" 104.03' 91.49' 102.03' N/A 7 (CO) 29' 121" 92" 104.05' 93.97' 101.63' N/A 8 (CO) 34" 121.5" 87.5" 103.97' 93.85' 101.13' N/A 9 (CO) 35" 120" 85" 103.70' 93.70' 100.78' N/A 10 (CO) 23.5" 120" 96.5" 103.74' 93.74' 101.78' N/A Elevation based on assumed garage slab elevation of 100.00'. "Invert measured from top of stickup P�AT� 3 Swinq Ties »A« B. 1 (CO) 9.3' 15.5' 2 (ST) 14.2' 24.2' 3 (ST) 21.7' 31.7' 4 (CO) 24.4' 34.3' 5 (CO) 25.1' 35.3' 6 (MT) 61.6' 71.5' 7 (CO) 80.3' 89.0' 8 (CO) 80.0' 89.4' 9 (CO) 79.8' 90.1- 10 (CO) 1 79.6' 91.0' P�AT� 3 MARK HANSEN P.E. CwsmTNG ENGINEERS TESTWG LABORATORY P.O. Box 4323 Pdmo. AK 99646-4323 P11on4•. (907) 745-4721 Fax: (907) 746-4721 n-maL• mhpNmtoonllnwn.t June 28, 2005 Work Order. 0507 Alaska Gravel Products PO Box 4343 Palmer, AK 99645 r Fax: 745-4454 Project: 2005 Materials Testing Subject: Sieve Analysis, Filter Sand Gentlemen: The following is the sieve analysis of the aggregate sampled on 6/28/05. Sample Location: stockpile Sieve Passing MOA Spec. 1/211 100% 3/8" 100% #4 100% 100 #10 78% #20 57% #40 3o% #60 9% #100 2% 0-2 #200 0.7% 0-1 The sample conforms to MOA specifications for filter sand. If you have any questions, please do not hesitate to call. Sincerely, Mark Hansen 1 cert[f ieb 3Dritting In by amoo.dbB SULLIVAN WATER WELLS PAL troy 67MM CMXMK. ALAMA taco • -.- a,,W3FtCWt„ Xt:MQI /9S Y7r J,�E.oP r a6�ta AOOFIM& A07' /D pgOSiKmmt CSoold. Oeftooku R� ibi-oq1 IAXMBaFlQaMMAdB8t.D-U-- III lsvWbcdmdatappowdpsMbmftW Wtl6 MIND MWmddOrt w 6Hairy CsCd>t Wd Drprd"a JoL d . Cm*QTYw-Izff9-4—v&amd mn • asp i,cims jo CAW LkWTJM A.>" � C;*YSfcLpAOanaGoom o? ted sAf wowlaret O's, tfd tAWM paw J. Wa IlofroddTmit¢14 it WA&ftheop�vAmb sand Oapntmlo ZISMIK L%. Stall i.r Stopipd feet r'] Parkvaforra Sktr1 iwt Sk7ppd bd Dmpft bm fN ied.b j0 loot ItiAtTsitf[dIMsOO rR�i�s QNm IIBIDOdOb/eeift G NcLR..,•E �a p�.n ' C,4s,.y6 STrcr<JY Yll i -e ego, : e. w f G ar�dar S If 5.4..�✓J S/ 6�w��� �jeR.lsr. Sit :y S.%,�� s-A..o,w 6R.4JE� -wffn. CC� YYFlnlOtt K lo"nsI I M I d top a ly ours to f dwA s Coq d tee vie/ wo lo the pops adwft l,Ms*kmft *1 do Cp Dopakrrst d t#nM & [Lars S@rvbw a Kft Depwtnot d EsrMa ffmn&d CaeergNort %Uau tiaorrptr ypNserrt OfEswkan.Yr Coreovaian A.W. MurFitt Company_ CONSULTING ENGINEERS & TESTING 13810 Venus Way • Anchonve, Alaska 99515 • Telephone (907) 345.2737 • FAX (907) 345.3264 September 15, 2005 Municipality of Anchorage Department of Health & Human Services On -Site Services P.O. Box 196650 Anchorage, AK 99519-6650 ATTENTION: Mr. Joe Goodall Civil Engineer RE: Eaton Park Septic Systems Lot 10 NEIA, T15N, RI W, Sec. 10, S.M., AK Chugiak, Alaska AWM Co. Job 05-394.14 Dear Mr. Goodall: We are in receipt of your telephone directive of August 31, 2005 (inspection letter request) and email of September 8, 2005 regarding the status of the septic designs on the referenced properties. This letter has been prepared in response to your determination. Mr. Ken Lang, R.L.S. the project survey and I trade a site visit on Thursday evening September 8, 2005 to establish the exact locations of the septic systems designed for Lots 9, 10, and 11. These locations were surveyed as shown on our design documents. We have determined that the accepting soils used in our designs are in fact still in place. Soil percolation tests were done at depths of 4.5 to 5.5 feet and all resulted in a rate of less than one minute per inch. You will note that the proposed systems are located near the fronts of the lots at 9 and 10 (soil in place) and to the rear at Lot 11 where soil was removed (4 to 6 feet). The existing soil surface (sandy gravel) would be the approximate bottom of the sand filter bed where the percolation test was done. Similarly, the same condition at Lots 9 and 10 (excavated partially at 4 to 5 feet) exists. Septic systems had to be located in these areas due to slope conflicts in the rear of the properties and protective well radii. Septic locations are very limited and digging new test holes will destroy additional septic area. Test pits for this work were dug to depths of 15 to 17 feet, no ground water or impermeable layers present. The well logs for Lot 9 and 10 shows sand /gravel to depths of 35 and 41 feet with static water levels at 185 and 175 feet, respectively. The Lot 11 well was drilled in 1965 with the current static water level at 173.6 feet. Geologically, the near surface soil at the lots is homogeneous and consistent over the first 35 feet with no groundwater or impermeable layers. Note aquifer testing was done in the subdivision development/approval process for which the MOA has this documentation (Aquifer Test Report, dated April 4, 2005 by Anderson Engineering). The designed system locations will be re-established by survey prior to construction. Construction of the piping Page 2 September 15, 2005 05-394.14 Eaton Park Lot 10 and beds will be difficult in that the upper 4 to 5 feet of backfill soil is gone. The sand filter can be placed directly on the natural sandy gravel and the total installation (piping, bed, tank) protected with a fine soil bedding/padding adequately compacted. Bed accepting soils will be verified and re -percolated if necessary and the whole backfilling operation closely scrutinized by our engineering stall. We understand that the contractor plans to use the sandy gravel embankment material in the rear of the properties for final grading to the required cover depths of our design. We hope that the foregoing will reverse your determination on the referenced septic systems. Please do not hesitate to call if you have any questions, or we can be of additional assistance in this matter. Sincerely, A.W. Murfitt Company ��'�`• a ,�^ P"' 49TH Its �',�•.Al1anVl.P,tu Allan W. Murfitt, P.E. 49 7-1 Q Registered Civil Engineer 4977-E ``+ �� F ss. Attachments: Well logs. Copy to: LII Construction, Inc. MUNICIPALITY OFANCHORAGE Development Services Department On -Site Water 6 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SWO50129 Legal Description: EATON PARK SUBDIVISION LOT 10 Design Engineer: 0009 A.W. Murfitt Company, Inc. Owner Name: L.H. CONSTRUCTION Owner Address: 12130 REGENCY DRIVE EAGLE RIVER. AK 99577- 0�p `rvv Cr i()�J Date Issued: May 18, 2005 Expiration Date: May 18, 2006 l 3° Parcel ID: 051 4[w�C /n a ggoo li' Site Address: -47t3UREGEN�Y DRIVE Lot Size: 40367 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑✓ Disposal Field [?] Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: 5--1 y—ds Issued By. AAX� Date: S -11S eS \ Municipality of Anchorage 1 Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWERMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING 01—(1(_-4-8 Parcel I.D. Number SW Property owner(s) L, 11, �°�5��°c�la7J Day phone S2 2— 64 16 Mailing address 12- 1319 g e A)ct/_ Ue 4,lo(P e1AZ. Zip Code l! 7 i Site address Code Legal description (Lot, Block & Sub'd.) LQ f !0 C+jcrt ) N ¢ )e SJ h ri r U rs ro& l Legal description (Section, Township & Range) (j)F_f,-nStia , (jt_ s, to, S /t?, -44 Lot Size 40'-=i!'q- Acres q.Ft. Number of Bedrooms THIS APPLICATION IS FOR: e ❑ Sewer Only Well Only Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. n (Signature of property owner or authorized agent) Permit/Rush Fees: 4/rD� '/� Waiver Fees: Date of Payment ftJ�l(15� Date of Payment Receipt Number: � Receipt Number. (Rev. 09104) A.W. Murfitt Company_ CONSULTING ENGINEERS & TESTING 13810 Venus Way • Anchorage, AW6 99515 • Tekrho (907) 345.2737 • FAX (907) 345.3264 May 11, 2005 Municipality of Anchorage Department of Health & Human Services On -Site Services Section 4700 South Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 ATTENTION:Mr. Jim Cross, P.E. RE: Septic System Design Four Bedroom, Single Family Dwelling Lot 10, Eaton Park Subdivision NE 1/4, T15N, RIW, Sec.10, S.M., AK. Thomas Development, Inc. Chugiak, Alaska Our Job 05-394.14 Dear Mr. Cross: The referenced property represents an undeveloped 40,367 square foot parcel. The proposed four (4) bedroom, single family dwelling is shown on the attached site plan, Plate 2. Our design data is summarized in the following dialog. 1. SOILS: Attached is a copy of the soil log/percolation test data and Site Plan. The log documents a Sandy Gravel (GP) with Silt soil profile to a depth of 13 feet below the ground surface. No water table was encountered with monitoring through 9/28/04. The receiving soil has a percolation rate less than one (1) minute per inch. A filter sand is required to slow the absorption rate. 2. BED DRAIN FIELD DESIGN: a. Percolation Rate: greater than 1 minute per inch with filter sand (CPP Palmer, T & J Services Wasilla). b. Allowable application Rate: 0.7 gallons/day/fl 2 c. Number of Bedrooms: 4. d. Design Flow: 600 gallons per day (at 150gallons/bedroom). Page 2. Lot 10 Eaton Park e. Minimum Absorption Area: 858 s.f. May 11, 2005 05-394.14 f. Maximum Total Depth (below original grade): 8.0 ft. (4'— 2" cover, 1.0 ft. sewer rock, 2.0 feet filter sand). g. Width: 15 fl. It. Minimum Length: 60 feet. i. Effective Absorption Area = 900 s.f. 3. SURFACE WATERS: There are no surface waters within 300 feet of the proposed septic system. There are no streams or drainages on the property. 4. TOPOGRAPHY: The septic site slopes to the north at 3 to 5, percent. No 25% slopes exceeding in the immediate area. 5. IMPACTS: On the basis of our site visit and the available site information, there are no current well and septic developments within 100 feet of this system. Accordingly, there will be no adverse impacts on adjacent wells or septic systems of adjacent lots when built as designed. 6. WELL and SEPTIC INSTALLATION: The well installation was completed March 1, 2005 by Sullivan Water Wells (copy of well log attached). The septic system designed herein shall be constructed in accordance with the most recent AMC 15.65 by an approved septic system installer. The installations shall be completed in accordance with the requirements of the On Site Well and Septic Permits. The overall Eaton Park development plan has already been submitted to DHHS but a copy is attached for information. Page 2. Lot 10 Eaton Park May 11, 2005 05-394.14 Please call our office at 345-2737 if you have any questions or need additional information. Sincerely, A.W. Murfitt Company Allan W. Murfitt, P.E. Registered Civil Engineer 4977-E COPY TO: LH Construction, Inc. Mr. Mike Irving ATTACHMENTS: Percolation Test Report, Bed Drain Field Design Plate 1, Site Plan Plate 2, Well Log. Performed For Thomas Development, Inc. Dela Pertonned: Lepel Description: Lot 10, Eaton Park Subdivision Township, Range, Section: NEI/4. Sec. I0, T15N, RI W, S.M., AK Depth 4 -6 SandyGravel with Si 2 0eCobbles (GP), brown. e 3- / tmoist 1 4- 5. -S 4 a 6 t 1 1 1 4 7- $ap4 s 9 a 9- e C 1 1 � 10- 4*et st s 12- 4 it 13- 114 IlSilty Sand and Gravel 17- 18_ o Water backhoe COMMENTS WAS GROUND WATER ENCOUNTERED? NO s YES. AT W W1T DEPTH? L Depth In W"N, After e Mentoring? No Water a Der:9/2M Reeding Date Municipality of Anchorage. t Nc'NEERS SEAL)ti, 1 Development Services Department t Or Gig;' •, �Zr Building Safety Division It ," • �i On -Site Water and Wastewater Program P • .. • +' -. 4700 South Bragaw St. • P.O. Boa 190650 Anchorage, AK 99519-0850 _.... •. . vA" muni orolonsle 2 thin (907) 7a7-7904 Nu 4977"L °i . � 'FE'S• !L ttn,r,� Soils Log - Percolation Test la?;;•'; Performed For Thomas Development, Inc. Dela Pertonned: Lepel Description: Lot 10, Eaton Park Subdivision Township, Range, Section: NEI/4. Sec. I0, T15N, RI W, S.M., AK Depth 4 -6 SandyGravel with Si 2 0eCobbles (GP), brown. e 3- / tmoist 1 4- 5. -S 4 a 6 t 1 1 1 4 7- $ap4 s 9 a 9- e C 1 1 � 10- 4*et st s 12- 4 it 13- 114 IlSilty Sand and Gravel 17- 18_ o Water backhoe COMMENTS WAS GROUND WATER ENCOUNTERED? NO s YES. AT W W1T DEPTH? L Depth In W"N, After e Mentoring? No Water a Der:9/2M Reeding Date Gross Time Net Time Depth to Water Not Drop 6" 9/18/04 3:41 PDT 0 0. 3:43 pm 2 thin 6- 6- /18/04 3:43 pm 0" 3:45 pm min 6" Ej r�.....nn.,vr nn.c (mlrlutef/InrJlt PERC HOLE DIAMETER O" TESTRUNBETWEEN 5 FT AND 5.5 FT PERFORMED BY: Russell ffepner, E.I.T. I Allan W. Mutt CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Sept. 18, 2004 T_ 13' MIN 5' MIN BUILDING CO MONITOR TUBE FILTER FABRIC 4- PVC (D3034) SLOPE 1/4 INCH PER FT. MIN. O NEW 1250 -GAL 2COMPARTMENT STEEL SEPTIC O TANK r --rte I I I I I I I I I I I I I I . I I I I I I I I I I CLEANOUTS (TYP) SYMMETRIC ABOUT C.L. F2' BOTH ENDS 4' SWEEP Co II TOWARDS TANK —I 1.50 FT. TYPICAL II 4' MT MIDDLE OF FIELD. PERFS. IN SEPTIC ROCK. SOLID SECTION ABOVE. I I � TEST PIT I PLAN 15'x 60' BED N. . 4' x 56' PERF. PIPES LAID LEVEL 4 PIPES AT 4 -FT CENTERS. A. W. Murfitt Com Job No. 05-394.14 Date: 5/09/05 Drawn: R MOUND BACKFILL TO DRAIN SEPTIC ROCK PER MOA SPEC.S FILTER SAND BED PER MOA SPEC.S 4' SVEEP CLEENOUTS VITH CAPS. r W' PERF. 6' No GW To 1T BED SECTION N.T.S 4' MIN dPE 1 FT. 2 FT. Notes: 1. No neighboring septic systems, wells, or bodies of water are located within 100' of this proposed system. 2. On -lot well to be 100' min. away from system. 3. System 10' min. from property line set back. 4. All pipe is 4" PVC (ASTM D-3034) with 4" perforated PVC used in the wide drainfield. 5. All distances shown on the above drawing are minimum for construction of the septic system. 6. Insulation required with 4' or less cover. 7. System to be installed by MOA certified installer. 8. Two (2) inspections are required by a Registered Civil Engineer. 9. No driveways on / over septic system. 10. 0.93 acre site undeveloped. Wni -um L H Construction, Inc. Septic Lot 10, Eaton Park Subdivision Chugiak, AK r r G X000 i"C RESIDENCE 7A 4A• ,ao• a a R 3, a 5.1 HOUSE DETAIL SCALE 1• m 30' B L 0 C K OUR ' MOUNTAIN NOTE: COVERED PORCH SEE ENGINEERS PLANS FOR LOCATION OF WELL AND SEPTIC. 1 SUBDIVISION LEGEND 300.4 EXISi1NG ELEVAnON 301.0 PROPOSED ELEVAnON SURFACE DRAINAGE LOT COVERAGE - 4.9x PLOT PLAN X AS BUILT ,_ SCALE _IL- - X50• GM NW 1361 Pr*d No. 05-096 Lang & Associates, inc. 11300 Daryl Ammm. Anchwo". Alwka 89515-3049 Registe9m07) 5u-6476 Phoma d Land Surveyors 907) =-4= Fax k9br,pf6akwm.nct / jdwV a00kwk4.naf OF oaMh flat 1 hawurw*war.d falic,d„0 d..arle.a Lot propKy Q taf 10. EATON PARK slleofvaloN :� � 49�i Dow" . w Dbk* Alaian n, d Mat the knpro.amn% Wkwbd tharaon an . .. :... t1a Prooaly Rnm and do not ararooal, ado thepropafy odjoor,t M1ado, Mat ° OW fW a f Mrq Qd llwalo wwooch a, 1M ourwwd .—. am no bya. frorwnh otos bac or eM,ar rlabla wnenft on add propatr oxapt = kWkaW Iwaa,. '� KOaE1H ed thfa tM 7rA parqf_dPn'kzoz - Laos - at Ana wo^ Akmka . Ma na sporrpy, of *a 0 w fa dolamka tha o,dow doa of am aa.r„ords onada. or rWrMlcfw .blah da nat aaoaor on the rewrdad nrkdluid n dn/, nU1. T S2 \\I I 1 1\ O, I I 1 \ CA0 p C \ 4 .p �• fF11 1 I 1 ZFa_. \ \ G•es \ ••a Z CO I X a I w ' .47MA I � \ E � I •` I N \ \ O 10 N% m[4Y-11-2005 03:35P FPOM: 70:3453264 Mar 03 05 03:!7p Diane, Sullivan 689-2259 Certifieb ]DrMing -tog by a=Co.mw SMLIV" WATER WELLS p.m am noo•» CmIC44ir- ALASKA 99W • _._ . AODfV=r� AaT 1D Dune 7 /, 40 pE3wmAdast SIA' Dv>kCcbmm q1 lAX �DQFfFG410af NEAlL� It/ __Si_ is "a lr'd at print bCo oW Stv :a fb UWcd of DMrq: t %f-mta:y t a cabb tool OepahotoRk dAd. Cm*+oTypa- v?aatt kid,R Diamder G if i Jo7.2. fat UnwTypc C!rVq Above Qcnw► oZ Mret stme a fff Fee,! FlacowrFaim f). gpra &Wwd-ks-- T. A 4 - Wan' wet' , , 01 , g Tim 4a as 0 open tde :.t Saeeeodt _ SW tad Supped t d Perfora6ars start Stotlpad tact GKxg-Fpw ltc�+.—..:rte C VbIww t.�itri Dwor taom $BEL to '2 O taa VAA Dasiecb.d tFwm Compkftge 40165 a No 'mm P:2 P.1 G ZI7Azt S ,<DP/VN s -t, -r; SiPv:Oo G�.�AJS� 4�t.2,� �k'RJEc. Sr c : 7' S fj SA.iO� t'aI:r1JE� �W�Tc! Qs9�rtaar t is tna resq«satary of re, pa�paty anter b albrrd a copy of the wd too m arc poor' aiha *. MMmidpaih N Archo QK Dspw%vwd cf MwM a FMaaan Srvtoea a droi Daoawtrnm+t of Enwhcnm"nrat Conamvotiort. M4atSu Boayh 2aM b wd of &wicra ental C wwvabon. MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Permit Number. SWO50012 fAro+1 �+ak s�o �t to r . Legal Description _ Design Engineer: 0000 None Required Owner Name: THOMAS DEVELOPMENT INC Owner Address: 24233 SKI ROAD CHUGIAK , AK 99567- Date Issued: Jan 26, 2005 Expiration Date: Jan 26, 2006 ParcelID: 051-111-54 Site Address: 024243 SKI RD Lot Size: 236982 SO. FT. Total Bedrooms: 0 Permit Bedrooms: 0 This permit Is for the construction of: ❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AACBO ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April IS, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -WHEN THE WELL HAS BEEN COMPLETED AND SATISFACTORY WATER PRODUCTION HAS BEEN DETERMINED, THE WELL DRILLER SHALL PLACE AN APPROVED SANITARY SEAL ON THE WELL HEAD AND NO PITLESS ADAPTER OR PUMP SHALL BE INSTALLED UNTIL AN APPROVED WASTEWATER DISPOSAL SYSTEM HAS BEEN CONSTRUCTED. THIS PERMIT IS FOR THE PROPOSED EATON PARK SID LOT 10 Received By. �11 /Date: V ` Issued By. Date: 24 c Parcell.D. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWERMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Number SW ZD Property owner(s) Q -e t_ LCph' Q)T 10(1/ Day phone 7'7- 7 6 fir/ Mailing Site ad( Code 4 9's /I Code dun, re -Legal description (Lot, Block & Sub'd.)v �mr I Q� L �1 TO►J (� q6 YC ��" C�n a (S fes/ -;�rLegal description (Section, Township & Range) Lot Size D•Aya-9'0'6"AReslSq - Number of Bedrooms THIS APPLICATION IS FOR: Sewer Only ❑ Well Only Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: El Hot Tub ❑ Jacuzzi Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of propgrty owner or authorized agent) Permit/RushFees: i�� oU Waiver Fees: Date of Payment: o�� Date of Payment: Receipt Number: (n3�fi3 Receipt Number. (Rev. 09104) MUNICIPALITY OF ANCHORAGE o Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 051-111-78 Legal description EATON PARK LT 10 Site address 24400 REBECCA HILL CIR Chugiak Current property owner(s) SHERMAN Expiration Date: Z 2.2Z X The On -site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: Az Original Certificate Date: 4/29/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory x Tank Age Advisory Arsenic Advisory Other COSA Approva"une 2022 MUNICIPALITY OF ANCHORAGE Development Services Department a = Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 051-111-78 Complete legal description EATON PARK LOT 10 Location (site address) 24400 REBECCA HILL CIRCLE, CHUGIAK, AK 99567 Current property owner(s) DALE & CHRISTINE SHERMAN FAMILY TRUST Day phone 2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: ® Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ® Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 19 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ® Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ .5 50 Date of Payment COSA# OSG Zq I I ? Waiver Fee $ Date of Payment Waiver # COSA Application.doc COSA Checklist.docx COSA Checklist Legal Description: EATON PARK LOT 10 Parcel ID: 051-111-78 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled 3/1/2005 Total depth 222 ft Cased to 222 ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) 18+ in. Date of flow test for COSA 4/17/2024 Static water level at beginning of test 171 ft. Well production at time of test 4.7 gpm Water storage tank volume NA gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate 7.74 mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date 4/15/2024 Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank 49” Date of pumping 4/12/2024 Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 12/21/2005 ALL standpipes present per record drawing Total measured depth from grade 7.5 ft (max) Measured depth to pipe invert from grade 4.3 ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective. (ED) If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 4/17/2024 Results Pass Fluid depth prior to test 0 in Water added 630 gal New fluid depth 0 in Elapsed time <1 min Final fluid depth 0 in Absorption rate 600 gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 6 in (MOA 0.5’ ED) Effective depth used 0 in (Final Fluid Depth) Effective depth (ED) remaining 6 in Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots & appears approximate with 0.5’+ ED. COSA Checklist.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 4/19/2024 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 04/19/24 www.muni.org/onsite Nitrate Advisory Certificate of On -Site Systems Approval # OSC241112 Subdivision: EATON PARK, Block: , Lot: 10 A water sample revealed a nitrate concentration of 7.74 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Since nitrates are known to slowly increase, we recommend you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. 1 fir" Ft 3 F �`u { Ma�Img Address P O' Box 19665p *:anchorage, Alaska 9�519`6650 * www mum org From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples. Municipality of Anchorage • -- Development Services Department <, j` Building Safety Division Onsite Water and Wastewater Program ° 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Q� Parcel I.D. tY;\-\\\= i$ HAA # 11190b01 50 ��N�dfo 1. GENERAL INFORMATION Expiration Date: Complete legal description Lot 10, Eaton Park Subdivision Location (site address or directions) 24400 Rebecca Hill Circle; Chugiak. AK 99577 Current Property owner(s) LH Construction, Inc. Day phone 522-1616 Mailing address Lending agency 12130 Regency Drive; Eagle River, AK 99577 James McDurmic Mailing address N/A Real Estate Agent Mailing Address Day phone 1 00-862-9744 E4 81686 Dena Lithgow, Northern Trust Real Estate Day phone 441-1339 North205 E. Benson Blvd.; Anchorage, AK 99503 Unless otherwise requested, NAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well 0 Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. . Name of Firm A.W. Murftt Company Phone 345-2737 Address 13810 Venus Way; Anchorage, AK 99515 Engineer's Printed Name Allan W. Murfitt 5. DSD7GNATURE Approved for Disapproved. ! bedrooms. Date 4nsros IM Ll .; NO 4977-E .r Conditional approval for bedrooms, with the following stipulations: Attachments: HAA Checklist X Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other By; Original Certificate Date: 57 b (R« 01M2) �... Municipality of Anchorage , Development Services Department Building Safety Division i On -Site Water 6 Wastewater Program 4700 South Bragaw, St. P.O. Box 198650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 3437904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 10, Eaton Park Subdivision Parcel I0:*54492-67t % A. WELL DATA well" w-+ Date completed y+ft Total depth 222 ft. If A, B, or C provide PWSID # _ Well Log (Y/N) Yes Sanitary not (Y/N) Yes Wires Properly Protected (YM) Yes Cased to 222 ft. Casing height (above ground) 24 in. FROM WELL LOG Data of test 3/1/05 Static water level 175 R. WON production 12 g.p.m. WATER SAMPLE RESULTS: Ccidarm -L—colonies/1 00 mi. Nitrate 1.69 mg.a. Arsenic: 2 mgA. Date of sample: B. SEPTICIHOLDING TANK DATA Tank Type/Material Steel Tank size 1250 gal. Number of Compartments 2 Foundation cleanout (Y/N) Yes Depression over tank (Y/N) No Date of ppmping N/A Pumper C. ABSORPTION FIELD DATA Date installed 12/21/06 Soil rating (g.p.d./ft2 or ft2/bdnn) 0.7 AT INSPECTION ft. 9— p.m- Other bacteria 0 colonies/100 ml. Collected by: Russell Heg ner. Eranineer Date installed 12020/05 Cleanouts (Y/N) Y" High water alarm (Y/N) No System type Bed Length 60 ft. Width 15 ft. Gravel below pipe 0.5 ft. Total depth 10_5 ft. Eft. absorption area _!20-#2 Monitoring tube Yes Depression over field No Date of adequacy test Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test — in. Water added_ gal. New depth_ in. Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >= g.p,d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed NIA Size in gallons Manhole/Access (YM) _ 'Pump on' level at _ in. 'Pump ofr level at _ in. High water alar level at Datum E. SEPARATION DISTANCES Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankll(It station on lot 11 W Absorption field on lot 128 Public sewer main WA Meals alarm & circuit requirements? On adjacent lots +125' On adjacent lots+?2s Public sewer menholeldeanout NIA Sewer /septic service line W Holding tank WA SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO: Building foundation 17' Property line 55_ Absorption field 8 Water main WA Wells on adjacent lots +126 Water service line 63' Surface water +150' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 45• Water Service line W Building foundation 35' Surface water +150' Curtain drain NIA Wells on adjacent lots +128 F. COMMENTS Area not landscaped at this time. G. ENGINEER'S CERTIFICATION I car* that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineers Printed Name Allan W. Murfitt Date 4/26/06 HAA Fee ri -f , -C — Date of Payment 14 d d ale Receipt Number I� (Rev. 12101) Water main NIA Driveway. parkirplvehide swrape V Waiver Fee E r NO 45 � F l• Date of Payment Receipt Number in.