Municipality of Anchorage Page 1 of 3
Department of Health and Human Services
Division of Environmental Services
On -Site Services Section 825'L' Street Room 502
P.O. Box 196650 Anchorage. AK 995m665o
w .cl.anchorage.ak.us (907) 343-4744
ONSITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SWO10032
PID Number: 051-832-01
No'eft:
MM&M Contracting
Wastewater System: New
Ado :
P.O. Box 670495 Chu iak AK 99567
ABSORPTION FIELD
per•
688-1236
Three 3 Bed 3)
Deep Trench
LEGAL DESCRIPTION
We K.UN.
1.2
Ta Deptk.arg"Fade:
cvwFr
8.5 Ft.
Bladt: Le: $1100rWO1:
3 8 Ton'ess Estates
Deph b ppe eohm ken ov" pale:
3.5
Grant Oeplh keneav, ppe:
Ft.
5 Ft.
TOwep: Range:
septan:
Re added aDo a 0nrW Vqe:
Grew Length;
2 Ft.
40 Ft.
Well: Existing
fravtl wan:
3
eianlw d erase:
Delta Oalwaan Mea:
F,.
1
N/A FL
CWlriem(Pm% A B. C):
Teal Dealt:Geed
b:
TOW aheprphonZ
PM hlelensl:
Private
Fl. >40 Ft.
400 Fr
ASTM D3034 PVC
Dreer.
Dale DnNed:
Stetc Water Le tl
YelaY•r
Deta hstaaed.
91 Ft
MM&M Contracting
4/11-12/01
Yeq.
P." Set 9:
cat" H..ght #1 Grand.
TANK
CPM
FI.
>3F1
SEPARATION DISTANCES
® Septic ❑ Holding ❑ S.T.E.P. ❑ Other.
To
Septic
Absorption
Lift
Holding
wiPrivate
Finn
Tank
Field
Station
Tank
severl6b
Anchorage Tank
1,000
Wee
>100'
>100'
N/A
N/A
>25'
Steel
Two (2)
swop,vw ter
>100'
>100'
N/A
N/A
LIFT STATION — NONE ON LOT
La LOW
>5'
>10'
N/A
N/A
e.
Gal
FeeNetinn
>5'
>10'
IN/A
N/A
.l.Twn°
N.
.ae M.
In.
.b.
kt.
aete.,oreh
None
Noted
P'anp1Aa1ij11O0e1
Elatlrral vdt, ve pedened hr.
Rewka.
21' Insulation Over Septic Tank.
BENCH MARK
Garage Slab
Aewewd Sew :
100.0 Ft.
Engineef._s Stamp
= `SOF
� .. ..
Inspections performed b .MEA
P� P y'
at
Dates: 1 4/11/01
.. . .
:•! yj••••T••••••)••• �•• �
2nd 4/12/01
A : MICKAEL E ANDEMN �
Department of Health
and Human Services approval��
:'•. CE -4331 .•
� s�� ,•
#t
Reviewed and approved by:
Date:
444'1 oo
`S
S1
S2
C4
M1
C5
Municipality of Anchorage Page 2 of 3
DEVELOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK 99519-6650 -343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number SWO10032
PID No. 051-832-01
PLAN AS -BUILT
SCALE 1" = 40'
OF
* : 491"''
101
-MICHAEL E. ANDERSON :
✓j CE - 4331
U
Municipality of Anchorage Page 3 of 3
DEVELOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK 99519-6650-343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number SWO10032 PID No. 051-832-01
N
N
NM
UU
N
U E 91.1 "`n
E U
i 361 3'
tp �w
"�.
R* 491B tv
.......... .
PROFILE AS-BUILTIO...
�
I"= 10, (t � . MICHAEL a ANDERSON .� i
0� CE .4331
ttl�ttotsc��'�'�
Municipality of Anchorage
Department of Health & Human Services
825 L Street, Anchorage, AK 99502-0650
SOILS LOG - PERCOLATION TEST
Performed For. MMBM ontradinm
Legal Description: Lot S_ Block 8_ Toy ac Estates
SLOPE
11
17
21
GP/GW
Well Graded
to
'oorly Graded
Gravel
Bottom of
Test Hole
South
Was Groundwater
Encountered? No
If Yes, What Depth?
Depth to Water
After Monitoring None
Date: 4112/01
S
L
O
P
E
Date Performed:
*� 4�91J
I03 f' : MICHAEL E ANDERSON
PO���'. CE -4381 l w
.r v
tll'fslp'••....•.a`�`'`
11 t `; ;`SW'l`'ao .
4/11101
SITE PLAN
See Site Plan
Reading
Dale Gross Net
Time Time
Depth To
Water
Net
Drop
1
11 -Apr 5:30
.75'
2
5:40
3.5•
2.75'
3
5:50
625'
2b•
4
5:51
1'
5
6:01
3.5'
2.5'
6
6:11
Perc. Rate: 4 MinAnch Perc. Hole Diameter. 6'
Test Run Between 8 FL and 9 FL
Comments: Perc. Cavity Presoaked Prior to Test Same Material as Tu2.
Performed By: Mike Anderson. I, Michael F. Anderson Certify That This Test Was Performed
In Accordance With Aft State and Municipal Guidelines In Effect On This Date: 8111101
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water Q Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Permit Number: SWO10032
Legal Description f tONJESS ESTA_ TES BLK _3 LT 8
Design Engineer: 0014 Anderson Engineering
Owner Name: MMBM CONTRACTING
Owner Address: P.O. BOX 670495
CHUGIAK , AK 99567 -
�{ -�/ • / CO
Date Issued: Mar 16, 2001
Expiration Date: Mar 16, 2002
Parcel ID: 051-832-01
Site Address:
Lot Size: 39879 SO. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
F✓ Disposal Field Q Septic Tank Holding Tank ❑ Privy ❑ Private Well Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling
(907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
AT THE TIME OF CONSTRUCTION THE ENGINEER SHALL PERFORM AN ADDITIONAL SOILS/PERCOLATION
TEST FOR THE UPGRADE SITE.
Received By:
Issued By
Date: S-19-0/
Date: - 46-01
Municipality of Anchorage
• Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
SA [•.
Parcel I.D. 051-832 _ 0t Permit Number SW0/0032
Property owner(s) MM&M Contracting Day phone 688.1236
Mailing address (1)P.O. Box 670495 Chuniak, AK99567
Mailing address (2)NHN TONY CIRCLE Zip Code -9956
Legal description (Lot, Block & Sub'd.) Lot 8. Block 3, Tonless Estates
Legal description (Section, Township & Range)
Lot Size 39,871 Acres/Sq.Ft.
THIS APPLICATION IS FOR:
Number of Bedrooms Three (3)
Sewer Only ® Well Only ❑
Sewer and Well ❑ Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees: 2 , Waiver Fees:
Date of Payment: �° ��,�7, L/ l Date of Payment:
Receipt Number. fit/' 1 Receipt Number.
(Rev. 12/00)
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 522.6779 FAX
March 12, 2001
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 8, Block 3, Tonjess Estates Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 8, Block 3, Tonjess Estates Subdivision intends to construct a three-
bedroom home on the currently vacant lot. We are therefore applying for a permit to
construct a new septic system on the lot to serve the new home. The attached Site
Plan and backup documentation identify the location and configuration of the new
septic system and the parameters used in the design. It also shows the location of the
alternate site and the existing well on the lot. A second dry well will be removed during
development of the lot. The location of the well casing is also shown on the Site Plan.
Several test holes have been placed on this lot over the past years. All of these holes
reveal well to poorly graded gravels with percolation rates under 5 minutes per inch.
Two test holes were recently placed on the lot at the locations shown which indicated
similar well to poorly graded gravel to depths of 17'. No groundwater was noted in
either test hole during excavation or during the monitoring period. We are therefore
proposing to place a 3' wide by 40' long absorption trench with 5' of drain field rock
beneath the distribution pipe. The pipe will be placed at 3.5' below the existing ground
surface and the total depth of the trench will be 8.5'. A minimum of 3' of cover will be
placed over the trench to prevent frost penetration and possible freezing.
The ground surface on the lot slopes as shown on the attached Site Plan. The area for
the new absorption trench, however, is fairly flat. The new trench will be constructed
parallel to the contours of the surface in conformance with Municipal requirements.
Grading will be accomplished to assure surface drainage is away from the new trench.
The existing drainage pattern on the lot will not be affected during development.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
Lot 8, Block 3, Tonjess Estates
March 12, 2001
Page Two
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely, Q
Michael E. Anderson, P.E. _ `P.• Sir�S
Attachments .'*: 49T" `` A.*°
P
*.MICHAEL E. ANDERSCN :
�j; J CE -4381
L.262.08 1605 / / 16 �r L• r "�I' I
r Naae•gge`w bnr
r.. �7J8.,f 767, rat r
o ?6 81.E y�0op
1�' 397 41. Iy 0j•0,
•a bn ryA 7 I
�b ,1•
�I '^ do ; h ,��9•� hRti //
OI O r-�i
f:
0
THIS P 8
ROJECT
yr J r •7 / N � rr.1
ar
' 1700 JBAr �
I li
9 / •
?s /
• / � RSO
/y
G S776.94
.9v6' 2'0
NE!•JS �9'E 204 17 47100 h00
�O
( JJ� R.50 04/
�r•J\a} 52•.50,
10 / I
AREA MAP
SCALE V=100'
TH
y+•0�00 �� 0, *.MICHAEL E. RSCN•�� V
" �• CE -43 I e
44 PRO�CSSION�-o'
v 669.5J'JO-w 660.33 81-72 62-59 1a0.J3
W O Q�h
X iV e nGr
ect,Sse
0
Existing
Well
ee
i�Yat�
C1RC��
SITE PLAN
SCALE 1"= 40'
LOT 8, BLOCK 3
TONJESS ESTATES
. 0
Existing
T.7— I 1
- r t
." WCHAEL L
CE -4331 •,.-
. s.
SS
LOT 8, BLOCK 3, TONJESS ESTATES
SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Three Bedroom Home Deep Trench System
Perc. Rate: 3.3 Min./Inch 1,000 Gallon Septic Tank
Application Rate: 1.2 GPD/SF 5' Drainfield Rock
3 Bedrooms X 150 GPD 11.2 GPD/SF = 375 SF of Absorption Area
375 SF/10 SF/LF = 37.5 LF Trench Length
Therefore: Construct an Absorption Trench 40' In Length by 3' Wide With 5' of Drainfield
Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 3.5' Below
Existing Ground. Total Depth of Trench to Be 8.5' from Existing Surface. Mound Over
Trench If Necessary to Provided Minimum Cover of 3'.
Natural
T.-'-�,, Backfill
Geotextile Fabric
5'
PVCs
P(SlottDown)
ield
3,
� 1
OF,A4 1144
TYPICAL DEEP TRENCH SECTION
(NO SCALE)* 491"
%... ......
.. .....G. t .. 0
NOTE: Grade Area Over Trench to Drain Away. ,
Minimum 6' Separation From Bedrock. �° A .MICHAEL E. ANDERSCN
Minimum 10' Separation From Lot Line. ° s . CE • 4381
Minimum 10' Separation From Water Service Line. °I �9'•,
Minimum 4' Separation From Groundwater. 411;1 `,�"";::
Municipality of Anchorage
Department of Health & Human Services
825 L Street, Anchorage, AK 99502-0650
SOILS LOG - PERCOLATION TEST
'e��astpp,
OF 4
-J
1... ... .... A.�
MICHAEL E. ANDERSCN • W r
I� Jam.•• CE -4381 Is
IL
Performed For: MM&M Contractino Date Performed: 10/22/00
Legal Description: Lot 8. Block 3. Toniess Estates
SLOPE SITE PLAN
1
2
3
4
5
6
1C
11
12
13
14
15
16
17
1e
21
OGIOL
TESTHOLE NO. 1
GP/GW
Well Graded
to Poorly
Graded
Gravel
Bottom of
Test Hole
South
Was Groundwater
Encountered? No
If Yes, What Depth?
Depth to Water
After Monitoring None
Date: 3/11101
See Site Plan
Perc. Rate: 3.3 Min./Inch Perc. Hole Diameter: 6"
Test Run Between 5 Ft. and 6 Ft.
Comments: Perc. Cavity Presoaked Prior to Test.
Performed By: Mike Anderson. I, Michael E. Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 3/12/01
Municipality of Anchorage
Department of Health & Human Services
825 L Street, Anchorage, AK 99502-0650
SOILS LOG - PERCOLATION TEST
Performed For: MM&M Contractino
Legal Description: Lot 8. Block 3. Toniess Estates
SLOPE
1® OG/OL
GP1GW
Well Graded
to Poorly
Graded
Gravel
10
11
12
13
14
17�Bottom of
Test Hole
18
21
North
South
Was Groundwater
Encountered? No
If Yes, What Depth?
Depth to Water
After Monitoring None
Date: 3111101
`o.,aeee�t
wo OF 44 tt
491" *0i
0 MICHAEL E. ANCERSCN
CE -4381
tl� PdOfESSt��" ���
Date Performed: 10/22/8a��`'
SITE PLAN
See Site Plan
Reading
Date Gross Net
Time Time
Depth To
Water
Net
Drop
1
24 -Oct 3:50
1.25"
2
4:00
4"
2.75"
3
4:10
6.5'
2.5"
4
4:11
1'
5
4:21
3.5'
2.5"
6
4:31
6"
2.5"
Perc. Rate: 4 Min./Inch Perc. Hole Diameter: 6"
Test Run Between 5 Ft. and 6 Ft.
Comments: Perc. Cavity Presoaked Prior to Test.
Performed By: Mike Anderson, I, Michael E. Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 3/12101
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 8, BLOCK 3, TONJESS ESTATES SUBDIVISION
GENERAL:
The scope of this project includes the procurement and placement of a
new 1,000 gallon septic tank at the location shown on the site plan.
Work also includes the construction of a new 40' long X 3' wide X 5'
effective depth absorption trench at the location shown. The
distribution line in the trench will be placed at 3.5' below the existing
ground surface. Total depth of the trench will be 8.5' below the
existing ground surface. All components of the septic system must
be placed a minimum of 100' from the existing well on the lot and on
the adjacent lot.
2. Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
4. Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
A new 1,000 gallon septic tank must be be procured from an approved
source and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
Lot 8, Block 3, Tonjess Estates Subdivision
March 12, 2001
Page 2 of 3
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
6. Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trenches to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Femco, or equal).
Lot 8, Block 3, Tonjess Estates Subdivision
March 12, 2001
Page 3 of 3
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as -built of the completed system.
(Please Complete either 10, Ie or Ie.)
WATER WELL RECORD
STATE OF ALASKA
DEPARTMENT OF NATURAL RESOURES
Division of Geological a Geophysical Surveys
Drilling Permit No.
A.D.L. No.
lo. Borough- Subdivision Lot Block Ib. 1/4 eln.
Satlien Ne. TarnshipN� Range E[] Meridian
finch Ton ons £>
—ef—ef
s0 W0
E-1DISTANCE AND DIRECTION FROM ROAD INTERSECTIONS -
S. OWNER OF WELL: JO.'. -co Prince/Tony. Scha
2412 F4•29th Ave.
Address: r 7
Anch.p Ak. 99�0�
Street Address and Arse of Watt Location
_
2.'WELL LOG
Feel Belay
SYl face
4. WELL DEPTH: (final)
S. DATE OF COMPLETION
'
t1. ,81
i 1
q li
• Material Type
Too
Bottom
_�—
Orgnnic: brogan rand soft.
O
2
e. Q able tool Oltofory ODrIven OD Us
13Auger UJetted Geared 0Other;
Till: grey end hard. 2 34
L'arpo very hard. bonldor
frrey co. or. 34
7)7
T.usE: Qohmeetic 0 Public Supply 0 lodu.tfy
0 Irrigation 0 Recharge 0 Comm efltal ,
0 Test Well 0 Other.
Till: Frey end herd. 37 46
Largo very hard boulder ray co. or. 46 48
Till: -grey and hard.
48
50
S. CASING: 0 Threaded 0 welded
alum. ' 61n. to 88 ft. Depth Weight '17 its./ft.
slam. In. lo—fl. Depth lNckvp tt.
Large very hard boulder :Trey color. 50 52
'fill: grey and hard. 52 54
Large very ?lard boulder
grey co]ore 54
57
s. FINISH of weu:oprri hole.
Type: Diameter:
Slot/Mesh Silo; Length:
Set baleen It. and ft.
Backfilling Gravel pack
Till': �-re and hard. 82
Lkarpo very hard boulder I,rey color. 82 84
Till: gray and hard. 84 86
Bedrock: brown end hard; with 86 96
vra er; 4U Lilo .
10. STATIC WATER LEVEL: 85 fl. 9
Bedrock: gr --en ar-d hard. 96 181
❑ Abase" or Q Beton land surface Dole ;
MUhIGPA ITY OF
Equipment used: orad line.
_Pi OF NEALT
&
11. PUMPING LEVEL beta. land aortae. and YIELD
179rt. atter 2 fire. pumping0o66g.p.m.
-
..
ft. Offer lire. pumping g:P.m.' •
•
12.GROUTING Well Grouted: ;© Yes 0 No
Materiel: ❑ Neat Cement []Other: natural
'
IS.PUMP: (If available) HP
Length of Drop Pipe ft. capacity g.P•M.
0 sabre. 0 Jai 0 Centrlflcol 0 Other
D
'
-
14.REMARKS:
18. WATER WELL CONTRACTORS CERTIFICATION:
IS. Waley Temperature .e 0 F 0 C
. This .%H was drilled ander my )urlsdlctton and this report Is true tome beef
of my kno.ledaa and belief, .
F'occ Prillin;.
AA
758
Registered Business Name
Hoy '/x:50
Contract License Number
Ada....'' 3. Chugixky Ah* 99:67
Signed:
Dau:
Aulhorlsed Rspresentaflee
Form 02-WWR (II/811
Copy OlstrlbuNon: WHITE -Stab OGGS, PINK -Driller, CANARY-Cuslemer
RETURN to, olylslon of Gwloglc.l end geophysical sYrvq. (Dus)
MAnchorage. Alaska !lSOl
pp9mvpInDrive Telepho : 277'615)
WATER WELL RECORD
Drilling Coroany Us" Foss Drilling
r... 1 pi..e teeelate either la. Its. or Its.
U.s.a.S. Loci No.
Ornlln, f.rat b.
A.O.L. No.
STATE Of ALASKA
DEPARTMENT op NATURAL RESOMI[S
Section b.
Tounsnip
HIS
Range
w
Meridian
I,MbrougN
Anch.
SYedivislo„
TonJees
Lot
8
2loclt
Its. Fraction
f 1
le. Distance and ",rection fro. Road Intersections
.Street Address and Area of Wali LOCatice
j. OWNER of WELL 'Jesse Prince/Tony Schaff
Addresst 2412 We 29th Ave*
Anchorages Alaska 99503
2. WELL LOG Net New
"ff
Notarial Trp* op bttaa
b WILL DEPTH, (cmgbted)
119 ft.
Surface Elevation
Date of
2%p12�84
Till: grey and hard with 0 1 61
5, gable tool [Data" ❑Driven ❑Dug
[3 Auger ❑Jetted ❑bred ❑other'
boulders.
ill: 11 ht brown medium 61 1 7b
TVa
s. usu �bralc ❑ruenc supply ❑ lndlstry
❑Irripetl*n ❑ ocha," ❑Co�ercl.l
❑Tact well ❑other,
hardness.
Till: xrey andar w t
boulders.
Bedrock: reen and ard.
Threed*d aid
7. CASINC: QUned
In. to Ci Z.It. Depth WlOhc 11►dls.
-in. to eft. Depth
E. FINISH or RLLtopen hole
Type; Demurs
Slot/Noah Sizes Length,
Sat bat shs ft. and ft.
flttingst
!. STATIC WATE11 LEVELt N/A ft.
❑Above ❑eelw land surface
Type of Nassuranant:
10. PONPINO LEVEL NIw land surface
N/A ft. after M/A .hrs. puepinp N/A I.P.M.
ft. after hrs. puapin9 _2-P-0-
11. RLL HEAD COMPLETION: In Approved Pit
❑Pitless Adapter 18 Inches above grade
12. SROUTINet Well Groutedl m Tat ❑b
Keterlalt ❑Neat ce nt ❑other, natural
17. pWpt (If .vailable) H►
Length of Dro► PIPs ft. Capacity -1-P.-
Types ❑SYbrrslble ❑NClprocating
Cl Jet ❑0thert
14. "cNA"utbore hole sealed with ap-
proved well seal and left for
15• WATER WELL CONTRACTOR'S CERTIFICATION:
This wll ra drillad under my jurisdiction and this report A true to the Nat of MY bno.ledge end belief:
Foss Drill AAA
*g .tale VI nay Y ntraCt GN1N 1,NaDef
Address: TI
signed: Data:
Yl1gf i IpI*alntat YI
Fare 02 -Wu" copy Distribution: WHITE - State DCCf, PINK - Driller, CANARY - Cos, r
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, ALASKA 99524
February 2, 1994
Municipality of Anchorage
Department of Heath & Human Services
825 "L" Street
Anchorage, AK 99502-0650
Subject: Lot 8, Block 3, Tonjess Estates Subdivision
Septic System Design
Impacts to Adjacent Properties
Dear On Site Services Engineer:
The terrain of the subject lot slopes as shown on the attached site plan
with no drainage problems or surface water. The drainage pattern will not
be affected by the development of the lot. Gravelly soil was found on the
lot with no subsurface water. Conditions appear excellent for an onsite
system. All existing wells located within 100' of the proposed system will
be abandoned in accordance with Municipal and A.D.E.C. Regulations prior
to placement of the new septic system. If the system is constructed as
designed, the following statements can be made:
1. The system, if constructed as designed, will have no adverse impact
on the wells currently in use or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact
on existing septic systems in the area or those to be constructed in
the future.
3. The system, if constructed as designed, will have no adverse impact
on reserved space, either surface or subsurface, on any lots located in
the area.
4. The system, if constructed as designed, will have no adverse impact
on drainage patterns in the area.
tie,^�4n��
f 0 f1. 3z�
Sincerely, a �: ••' ..... '..- � •1
Michael E. Anderson, P.E.
�; ^ .1.: _":.^%:lar. "vds•:.�^ 00
{p Fc Michael E. An Wrwn W of
�� 5�c �• 4381 • E •�, C\V AV
C F%OFE55O�..v ij-
Lot 8, Block 3, Tonjess Estates Subdivision
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Four
Bedroom Home
I
Shallow Trench System
Perc.
Rate
T.H. #1:
2 Min./Inch
1,250 Gal. Septic Tank
Perc.
Rate
T.H. #2:
19 Min./Inch
Min. 2' Accepting Soil
Avg.
Perc.
Rate: 11
Min•/Inch
4' Drainfield Rock Under Pipe
Application
Rate: .8
GPD/SF
4 Bdrms. X 150 CPD / .8 GPD/SF = 750 SF
750 SF /5'(Width) • .5 (Reduction Factor) = 75'
Therefore: Construct a Shallow Trech System, 75' (Length) X 5'
(Wide). Place 4' of Drainfield Rock beneath the Distribution Pipe.
Place Distribution Pipe 3.5' below orginal ground.
y a •YrEaif:i:.:.
��,Nochad E. Anderson <y'
�O'J� a <381 • E � �c"r
I 1540oc T: jD2p4rJ L I I I 1 I
I
--
—.1— —i )A-17UXAL— I I i I I r I !
I i iiOMC
--
.--
1
I 101 I 1 I 1zsv'G
',,w
—r r S"77c. Twit
— t
—
_L
v6�
I i
T) ;
1 1 I I 1
.75-
1—j!i
`rYP� ,�J-rz:cNuI41 S64I 7n,l i i i i _! I Syrr
Vl�t,l
_-
�,;h
—Az
LAW ---
I. �r...... lea**
1 1
l
. 1 1 1 1 1 1 1 c`'' 'a iT�•�i:,'Y 1'sr
y a •YrEaif:i:.:.
��,Nochad E. Anderson <y'
�O'J� a <381 • E � �c"r
"- QENGINEER'S SEAL)
r„
Municipality of Anchorage 'I r^ '. Id
DEPARTMENT OF HEALTH 11 HUMAN SERVICES . ..•� F�t.gqjj
825'L" Street, Anchorage, Alaska 99502-0650 LG Gltiatie(�s+
SOILS LOG — PERCOLATION TEST �0 Michad E. Andc'wn• f
Bit �'•° 4351•E �
PERFORMED FOR: 14Lc•'I (,.I��+a&�v(!^✓1 L DATE PER FORA
LEGAL DESCRIPTION: �L✓/ fON1/ G�/ Township, Range, Section:
1 OE P.�„ �" ESTiYj�5,5uBD
2 v..
• o
3
e • e�
e••
4jrele C,
C��G►�
6 0.
'e'•: tea//
7 p�•�
8 -
15
'•:p;
//
16
•d•O•
(O cc,
to. 10
/
•e s
18
18-
0
o
a. 17
11
"=
5•'7s
20
B
2
12-
o
13
1 3
.•
" are
14
SJ
/v
::
S
15
'•:p;
//
16
•d•O•
(O cc,
7
17-
6y
/
7.18
18
18-
0
o
a. 17
19
•0 yo
5•'7s
20
B
COMMENTS 7est As/t AVAs
WAS GROUND WATER _ 1
ENCOUNTERED? /Y
IF YES, AT WHAT
DEPTH?
Depth he Waer A8� 3/�91t
Mmltering7 /
Dole
SITE PLAN
Reading Date
Grose
Time
Net
Time
Depth to
Water
Net
Drop
6y
/
7.18
+tY t
36
a. 17
/o
/34 7.a
5•'7s
SJ
5.10
/v
liil 7.54f
,7S
5i o
17-75
5•1/
PERCOLATION RATE Z (mmutevinch) PERC HOLE DIAMETER L
TEST RUN BETWEEN S FTAND G FT
PERFORMED BY / I "" ••t,� I THAT THIS TEIST, WAS PERFORMED IN
ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE
72-008 (Res. 465)
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 `L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
D
PERFORMED FOR: 4Lc-�I je�— &JL%o rJ DATEPER
LEGAL DESCRIPTION: ^' �Bl� Township, Range, Section:
Y��/ e D SLOPE SITE PLAN
1 •v o'
2 p.
.o
3 oo'r.
4 0
p A
Qe pa:
5 `i7 C
6 'tz
7
j.p.
• •n p
9 , .•
/ate ° O •,'
• / o
r , l7. �11l�µ,JnL qr.•P'
12 %b 0:0
130;•• J. Samei M�/4.
°v -a A��• IL'lirt
14 ,r
°• OCG• 20
15 :�°�
WAS GROUND WATER
ENCOUNTERED)
IF YES. AT WHAT
DEPTH?
Depth to Water After
monitoring? or
• ���ta>•tafil�t;•��
' ■■■■■.■■■.
Reading Date
Grou
Time
Net Depth to
Time Water
Net
Drop
/111,10194
S:0,5
9,
f
z
L:)
//.Zs
1757
t
4.5
/
)
e,
i
5:05,
it S
8
e l
:c/
L
19
53
1.7
20 /q -frr
PERCOLATION RATE q�� (mmutevmcn) PERC HOLE DIAMETER _,r_
TEtST RUN BETWEEN 9% FTAND O'v FT
COMMENTS
PERFORMED BY: �n hWrIl`' I �Y'k'���'� �"�' T+' THAT T/rIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE ZJ d z7y
72-008 (Rev. 4185)
Municipality of Anchorage
• Development Services Department ;►�:
Building Safety Division
-
On -Site Water 8 Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage. AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051-832-01 HAA#
1. GENERAL INFORMATION Expiration Date: L3 S— 0 3
Complete legal description TONJESS ESTATES S/D: LOT 8, BLOCK 3:
Location (site address or directions) 21546 TONY CIRCLE
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
ERNEST k SHARON JOHNSON Dayphone 688-3690
C/O REALTOR
Day phone
STEVE SHELL w/ PRUDENTIAL VISTA Day phone 351-9633
16635 CENTERFIELD DRIVE EAGLE RIVER. AK. 99577
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 3
3. TYPE OF WATER SUPPLY:
Individual Well
N
Individual Water Storage
❑
Community Class Well
❑
Public Water System
❑
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
N
Individual Holding tank
❑
Community On-site
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an Independent professional civil
engineer registered In the State of Alaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal andlor
water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work.
Note: Alaska Water and Wastewater Consultants, Inc. shall be paid $ at, orprior
to closing for the engineering services provided.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal afrixed hereto and as of the validation date shown below, I verify that my
Investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system Is(are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
Information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm ALASKA WATER do WASTEWATER CONSULTANTS. INC.
Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE. AK 99507
Engineer's Printed Name JEFFREY A. GARNESS. P.E.
Engineer's Comments:
In conducting this evaluation, AKW WC, Inc. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines 8 Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identirtable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. AKW WC, Inc. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report Is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
5. DSD SIGNATURE
Approved for 3 bedrooms.
Disapproved.
Phone 337-6179
Date 6 111L.103
Conditional approval for bedrooms, with the flowing stipulations:
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
Manitenance Agreements
Supplemental Engineer's Reort
Other
ON-SITE • •'
WASTEWATER
`RROGRAIr
.. •* A
By: IG��Jiti/ �A%. Original Certificate Date:
(Rm. 12)01)
Municipality of Anchorage
• Development Services Department
Building Safety Division
On-Sbe Water 6 Wastewater Program
47W South Bragew St.
P.O. Box 196850 Anchorage. AK 99519-6650
www.cLanchorageak.us
(907)943-79%
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: TONJESS ESTATES S/D: LOT 8, BLOCK 3: Parcel ID: 051-832-01
A. WELL DATA
Web type SATE If A, B, or C provide PWSID# N/A Web Log (YIN) YES
Date completed 1984 Sanitary seal (YIN) YES Wires Property Protected (YIN) YES
Total depth 181 ft. Cased to 88 ft. Casing height (above ground) 24+ in.
FROM WELL LOG AT INSPECTION
Date of test 9/27/84 5/21/03
Static water level 85 ft, 179 ft.
Well production 0.66 g,p.m. 00.18 g.p.m.
WATER SAMPLE RESULTS: •1,140 GALLONS OF STORAGE IN BASEMENT
Collform 0 colonie3/100 ml. Nitrate 3.55 mg./L. Other bacteria 0 colonle3/100 mi.
Arsenic:0.OW mg./L. Date of sample: 5/22/03 Cobected by. AKWWC. INC.
B. SEPTIC/HOLDING TANK DATA
Tank Type/Materlal SEPTIC / STEEL Date installed 4/01
Tank size 1000 gal. Number of Compartments 3 Cleanouts (YM) YES
Foundation deanout (YM) YES Depression over tank (YIN) NO f1 High water alarm (YIN) N/A
Date of pumping 03 Pumper Tf% Pur+9 i„n,
C. ABSORPTION FIELD DATA -*BELOW EXISTING GRADE
Date installed 4/01 Sob rating .p.d. r ft%dno) 1_2 System type TRENCH
Length 40 ft. Wkfth 3 A. Gravel below pipe 5 ft.
Total depth 009.6 M Eft. absorption area 400 ft' Monitoring tuba YES Depression over field NO
Date of adequacy test 5Z21/03 Results (Pass/Fall) PASS For 3 bedrooms
Fluid depth in absorption field before test DR' In. Water added 705 gal. New depth DRY in.
Elapsed Tine: 0 min. Final fluid depth DR' In. Adsorption rate >= 450+ g,p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date
D. LIFT STATION
Date installed
"Pump on" level at _in.
E. SEPARATION DISTANCES
Size In gallons
High water alarm level at in.
Cycles tested Meets alarm & circuit requirements?—
_* f4v', &a(.& uF W4 , -, e�abE of-ra
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+ On adjacent kits 100'+
Absorption field on lot '*' 100.12 On adjacent kits 100'+
Public sewer main N/A Public sewer manhole/deanout N/A
Sewer /septic service line 25'+ Holding tank N/A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property Ane 5'+ Absorption field 5'+
Water main N/A Water service One 10'+ Surface water 100'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main N/A
Water service line 10'+ Surface water 100'+ Driveway, parkingNehide storage 50'+
Curtain drain NONE KNOWN Wells on adjacent lots 100'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
/ certify that I have determined through field inspections and
review of Municipal records that the above systems are in ....... ' • ' """ •"""
conformance with MOA HAA guidelines in effect on this date.
et a A. Corn s
Engineer's Prin Na a JEFFREY A. GARNESS -79
Date <ri/ ii j e�ea' ........ • ' �r
�p of�sfbnd
HAA Fee Waiver Fee $
Date of Payment Date of Payment
Recelpt Number- Receipt Number
(RSV. (afo+)
05-30-03 05:37PM FROM-CTiE ENVIROMENTAI SRV
SCS RKN
1032884001
Client Name
AK Water & Wastewater Consultants Inc.
Project Namefil
Lot B. Dlk 3, Toniess Estates
Client Sample ID
Outside Faucet
Matrix
Drinking Water
Sample Remarks:
Results PQL
Metals Department
Arsenic 0.00200U.
9075615301 T-842 P.02/02 F-928
All Dateslflmet are Alaska Standard Time
Printed Date fime
05/3012003 16:37
CollectedDate/flme
051272003 7:50
Received Daterrime
05/27/2003 13:00
Technical Director
Stephen C. Ede
Releated By
Allowable Prep Analysis Init
Units Method limits Date Date
0.00200 1119/1- EP200.9 (<-0.05) 05129103 05/30/03 3MP
05-27-03 01:52PM FR011-CHE ENVIRMENTAL SRV 9075615301 T-699 P.02/01 F-710
SGS ReLN
1032823001
All Dates/rimes are Alaska Standard Time
Client Name
AK Water & Wastewater Consultants Inc.
Printed Date/ Time 05/27/2003 11:44
Project NanxM
L8, D3, Tonjess Estates
Collected Date/Time 05/2212003 8:47
Client Sample ID
Outside }lose Bib
Received Date/Mme 05/22/2003 12:55
Matrix
Drinking Water
Technical Director Stephen C. Ede
Released lly —�r—i a—��
Sample Remarks:
Allowable Prep Analysis
Paumneter
Results PQL Units
Method Limin Date Dam Init
Waters Department
Nitrate -N
3.55 0.100 mg/L
EPA 300.0 (<-10) 05/22/03 1S
Microbiology Laboratory
Total Coliform 0 col/100mL SM1992220 (<-l) 05/22/03 KAP
L
05/16/05 FRI 09:12 FAX 907 562 5485 PRUDENTIAL VISTA REAL E
Q1002
FROM COINTF i REPL_TY
pl-a•E No. 907MI12M
� Rug.
08 2001 09:38M P2
r
•„
1}.
W
•tw.. '•�-•!
•7.02,
..
,
.....�
to
05
uu�r
F • ' /4
d
�
. s4.i�P . "1
s'i`t 444ti.
<Ft6t
om7V 80 5
•+,:3.y
Z• 3 5, 74(-
A.S.-BUILT
I7wtetiyceT*'that I have surveyed the following desa3ed
pm�,e,ty_E_or Ir B/eck 3.
TcvvSliS1 6J7—AYES st/BR.
c�'f1e,�y a. , 7 rs'N R ►"! ST
Anchorage 1Rewrdmi; P4t4ncL AlaskP. surd that the prove -
mots situated ate,rtthin the ptrtperty Bnes.nd'de not _
a"Wor enaoadt an the peopettr lying adjacent geeeeto, that
no fmptoveaeEnh on ptopaty lying adtahcrttt thetet6 enaaach.._:
an IM•peio 614oettbnnd that there Mena soadwayS.'
a
transenafioti )bra other visible oaxments•on said property. -
coapt as htdiated haven.
Dawtd at Emla ifiver, ALAI
this /S. ,t,•,of N•+- }p2aol ,
'
ROBERT C. JOHNSON
SC/tCEi Reaistemd Land SarvevorNo. B� LS
r
•„
1}.
W
. s4.i�P . "1
s'i`t 444ti.
<Ft6t
om7V 80 5
•+,:3.y
Z• 3 5, 74(-
A.S.-BUILT
I7wtetiyceT*'that I have surveyed the following desa3ed
pm�,e,ty_E_or Ir B/eck 3.
TcvvSliS1 6J7—AYES st/BR.
c�'f1e,�y a. , 7 rs'N R ►"! ST
Anchorage 1Rewrdmi; P4t4ncL AlaskP. surd that the prove -
mots situated ate,rtthin the ptrtperty Bnes.nd'de not _
a"Wor enaoadt an the peopettr lying adjacent geeeeto, that
no fmptoveaeEnh on ptopaty lying adtahcrttt thetet6 enaaach.._:
an IM•peio 614oettbnnd that there Mena soadwayS.'
a
transenafioti )bra other visible oaxments•on said property. -
coapt as htdiated haven.
Dawtd at Emla ifiver, ALAI
this /S. ,t,•,of N•+- }p2aol ,
'
ROBERT C. JOHNSON
SC/tCEi Reaistemd Land SarvevorNo. B� LS
ALASKA WATER F& WASTEWATER
CONSULTANTS, INC.
May 27, 2003
Ernest and Sharon Johnson
C/o Prudential Vista
Attention: Steve Shell
16635 Centerfield Drive
Eagle River, Alaska 99557
Subject: HAA for Private Well & Septic System. Lot 8, Block 3; Tonjess Estates S/D.
To whom it may concern:
The subject lot has a 3 bedroom house on it, which is served by a private well and septic system.
The results of the field investigation and adequacy tests are summarized as follows:
A. WELL: The water system consists of a water well with a 1,140 gallon bladder storage tank
inside the basement. The storage tank was bypassed in the middle of our test. Prior to our test on
5/21/2003, the static water level was at 179 feet below top of casing (BTC). A total of 705
gallons was pumped out the well and the storage tank, which caused the static water level to drop
to 485 feet BTC, and also caused the pump protector to shut the well pump off. The well was
allowed than to recover over night with the breaker for the well turned off. In the morning, we
returned to the property and found the static ware level to be at 364 feet BTC ( a rise of 121 feet).
A total of 196 gallons was pumped from the well, which caused the static water level to drop to
489 feet BTC, and caused the pump protector to shut the pump off. Based upon this data, the
well production is 0.18 gallons per minute or 259 gallons per day (196 gallons in 1103 minutes
of recovery). The Municipal requirements for well production for a 3 bedroom house is 0.32
gallons per minute. As can be seen, the well production from the well does not meet MOA
requirements. However, according the MOA water well ordinance AMC 15.55.070, the well
production can meet the MOA requirements with a water storage system. The minimum amount
of storage for a well that produces 150 gallons per day or more is 500 gallons. Given the fact that
there is a 1,140 gallon bladder tank in the basement, the well production with the storage system
des meet MOA requirements.
Water samples for nitrate and bacteria were taken on 5/22/2003. A water sample for arsenic was
taken on 5/27/2003. These samples were taken to the lab for testing. As soon as the results are
available, we will fax them to you.
3701 E. Tudor Road, Suite 101 * Anchorage, Alaska 99507
Ph: (907) 337-6179' Fax: (907) 338-3246' Website: akwwc.com
One deficiency that was found during our inspection was the well wires on the outside of the
casing were exposed 10 inches from the ground level. In order to submit for a Health Authority
Approval (HAA), we will need this fixed by either replacing the conduit so that no wires are
visible or by mounding dirt around the casing so that the wires are not visible.
Two well logs were found for the property and are on record with both the MOA and the State's
Department of Natural Resources (DNR). It is unclear which log is for this well. As can be seen
from the attached logs, the wells are shallower than the static water level during our test. It is our
opinion that one of these wells has been deepened in the past with no record of this work being
filed at either the MOA or DNR. According to these logs, there should be two well on the
property. During our site visit, only one well was found. If the other well does exists, it must be
permanently decommissioned per AMC 15.55.060 (see attached) prior to submitting for the
HAA.
B. SEPTIC SYSTEM ADEQUACY TEST: The septic system consists of a 1,000 gallon
septic tank and a drainfield is a 3 foot wide trench, which is 40 feet long, and has an effective
depth of 5 feet. Prior to starting the adequacy test, the monitoring tube was found to be dry. A
total of 705 gallons was added to the drainfield with the monitoring tube remaining dry. Based
upon this data, it was determined that the absorption rate of the trench exceeds 450 gallons per
day, as required for a 3 bedroom house.
If you have any flyiystions, please contact us at 337-6179.
.E., M.S.
3701 E. Tudor Road, Suitc 101 • Anchorage, Alaska 99507
Ph: (907) 337-6179' Fax: (907) 338-3246' Website: akwwc.com
15.55.060 ANCHORAGE ASUNICIPAL CODE
2. The date the well was completed; k.
3. The total depth;
4. The total depth of casing;
5. The location and type of well completion;
6. Static water level below the top of the
casing:
7. Yield; and
S. Height of casing above finished grade.
li. Well logs and as -built. The licensed well
driller shall provide a well log to the property
owner within 30 days of completion'of the well.
Within 60 days following the completion of the
well or drilling activity, the property owner shall
submit to the department a copy of the well log,
the results of other drilling activities conducted
under the permit, and an as -built drawing on an
SYa by 11 inch sheet to a scale of not smaller than
one inch to 50 feet showing all data and informa.
tion shown on the site permit plan including the
location of the well and/or other drilling activities.
1. The well log shall include at least the
following pertinent information:
a. The property owner's name;
b. The legal description and street ad-
dress;
C. The method of drilling (rotary, cable
tool, etc.%.
d. A description, relative depth, and
thickness of each soil stratum pene-
trated from the ground surface to
the total depth;
e. The relative depth and thickness of
each water bearing stratum (aqui-
fer) penetrated;
L The total depth drilled;
g. The length, diameter, wall thickness
and type of casing used;
IL A description of the liner (if used)
and the length and setting depth;
L The depth and number of perfora-
tions, (if any) in the casing and/or
liner,
The static water level and drawdown
level;
The well production test results in-
cluding the method of testing;
The dates of commencement and com-
pletion of drilling operations;
The number and date of the well
drilling permit issued by the depart-
ment;
The name and address of the li-
censed well driller, and
A description of the method of disin-
fection process used upon comple-
tion of the well.
I. Water quality standards. Water used for
domestic purposes shall not contain concentra-
tions exceeding the following ratios:
1. Total coliform bacteria -'0 colonies per 100
Mi.
2. Nitrate - 10 mg per liter.
3. Other bacteria - 10 colonies per 100 ml.
J. Well decommissioning. Wells may be tempo-
rarily or permanently decommissioned in accor-
dance with this subsection:
1.
2.
j. The type and location of any screens
used;
Supp. No. MA 1 AMC 15.55-8
Temporary decommissioning. A well may
be temporarily decommissioned by remov-
ing the pump, disconnecting the water
service line from the residence, and in-
stalling and maintaining a water tight
cap or seal.
Permanent decommissioning. A well may
be permanently decommissioned by one of
the following methods:
a. Perforate the casing from the bottom
to within five feet of the land sur-
face, remove the top five feet, then
pressure grout the entire length.
b. Withdraw the casing and fill the
borehole with grout, puddled clay, or
bentonite as the casing is being with-
drawn.
C. Cut off the casing at a point two feet
below ground level and fill the cas-
ingwith a concrete or bentonite slurry.
WATER WELLS
If bentonite is used, the top ten feet
(ten feet below the top of the cut off
casing) shall be filled with cement
slurry. The top of the cut off casing
shall then be sealed with an 025
inch thick (or thicker) plate firmly
welded to the top of the casing.
(AO No. 96-98(S), i 6, 8-13-96)
15.55.070 General standards for potable wa-
ter hauling and storage facilities.
A. When well productivity is less than the
requirements of subsection 15.55.060.E. water
storage facilities shall be installed.
1. A permit to install water storage facilities
shall be obtained from the department
prior to installation. The permit applica-
tion shall include:
a. The legal description of the property,
b. An as -built site plan or proposed site
plan meeting the requirements of
subsection 15.55.050.33.1. and includ-
ing the location of the water storage
facilities; and
c. The number of bedrooms served by
the well and/or water storage facili-
ties;
B. Location of buried wafer storage facilities.
The location of buried water storage facilities
shall be at a site readily accessible year round for
testing, repair or maintenance purposes. The min-
imum separation requirement between buried
water storage facilities and other specified facili-
ties and areas shall be:
15.55.070
MINIMUM SEPARA-
SEPARATION OF
TION DISTANCE MV
TANK FROM
FEET)
Private sewer line
25
Hydrocarbon storage
25
tank
Sewer trunk line
1 75
Sewer manhole or
100
cleanout
Solid waste holding or
100
septic tank
15.55.070
1. The ground surrounding the access of the
storage tank shall be sloped or contoured
to allow surface water to drain away.
C. Water storage facility specifications. Speci-
fications and requirements for water storage tanks
and facilities, for both interior and exterior appli-
cations are as follows:
1. Water storage tanks shall have National
Sanitation Foundation (NSF) approval,
or,
2. Water stozaQe tanks shall be designed by
an engineer and manufactured by an ap-
proved tank manufacturer. Materials and
coating used in construction shall be ei-
ther U.S. Food and Drug Administration
(FDA) or NSF approved food grade.
3. All components of water storage facilities
shall comply with the latest adopted edi-
tion of the Uniform Plumbing Code as
amended where applicable.
4. Water storage tanks shall have a mini-
mum capacity of:
a. One thousand gallons for homes up
to and including tbree bedrooms with-
out wells or having a well producing
less than 150 gallons per day. Each
bedroom above three bedrooms shall
add 250 gallons to the required ca-
pacity of the tank.
b. ' Five hundred gallons for homes with
wells producing 150 gallons or more
of water meeting the requirements
of subsection 15.55.0601. per day
but less than the'requirement,of
15.55.060E.
5. An exterior water storage tank shall have
a minimum of four feet of cover, or insu-
lated to protect from freezing: Tanks bur .
Supp. No. KA 1 AMC 15.55-9
MINIMUM SEPARA-
SEPARATION OF
TION DISTANCE (IN
TANKFROM
FEET)
Septic absorption field
100
Animal feed lots, shel-
100
ters and containment
areas
1. The ground surrounding the access of the
storage tank shall be sloped or contoured
to allow surface water to drain away.
C. Water storage facility specifications. Speci-
fications and requirements for water storage tanks
and facilities, for both interior and exterior appli-
cations are as follows:
1. Water storage tanks shall have National
Sanitation Foundation (NSF) approval,
or,
2. Water stozaQe tanks shall be designed by
an engineer and manufactured by an ap-
proved tank manufacturer. Materials and
coating used in construction shall be ei-
ther U.S. Food and Drug Administration
(FDA) or NSF approved food grade.
3. All components of water storage facilities
shall comply with the latest adopted edi-
tion of the Uniform Plumbing Code as
amended where applicable.
4. Water storage tanks shall have a mini-
mum capacity of:
a. One thousand gallons for homes up
to and including tbree bedrooms with-
out wells or having a well producing
less than 150 gallons per day. Each
bedroom above three bedrooms shall
add 250 gallons to the required ca-
pacity of the tank.
b. ' Five hundred gallons for homes with
wells producing 150 gallons or more
of water meeting the requirements
of subsection 15.55.0601. per day
but less than the'requirement,of
15.55.060E.
5. An exterior water storage tank shall have
a minimum of four feet of cover, or insu-
lated to protect from freezing: Tanks bur .
Supp. No. KA 1 AMC 15.55-9
15.55.070
ANCHORAGE MUNICIPAL CODE
led with less than two feet of cover shall
have calculations submitted by an engi-
neer showing adequate measures have
been taken to prevent the tank from freez-
ing.
6. Access to water storage tanks shall be
dearly and permanently marked "potable
water.'
7. Water delivery to water storage facilities
shall be accomplished only by water haul-
ers certified by the State ofAlaska Depart-
ment of Environmental Conservation
(ADEC).
8. Homeowners may haul water to their own
water storage facilities provided they ob-
tain the water from a source approved by
ADEC and use a tank approved by this
department.
(AO No. 96.98(S), 4 7, 8.13-96)
15.55.080 Well duller and pump installer cer-
tification. - .
A. It shall be -unlawful for any person or com-
pany to engage in the business of drilling or
deepening a water well for domestic use unless
that person or company holds a well driller's
certificate issued by the department.
B. It shall be unlawful for a person or company
to engage in the business of installing, removing,
or repairing a water well pump, or engage in any
other subsurface activity on a water well for
domestic use unless that parson or company holds
a valid pump installer certificate issued by the
department.
C. A well driller's or pump installer's certifi-
cate shall be valid for a period of one calendar
year and shall be mewed each subsequent year
thereafter. • -
1. A certificate shall be issued by the depart-
ment annually only when the well driller
or pump installer has completed a train-
ing class conducted by the department
within the past 24 months.
2. The.certifieate may be revoked by the
department if the certificate holder has
been found guilty of or pleads guilty to an
offense under this chapter. The period of
revocation shall be according to the fol-
lowing schedule:
a. One offense within the previous five
years shall result in a revocation of
the certificate of one month.
b. Two offenses within the previous five
years shall result in a revocation of
the certificate of two months.
C. Three offenses within the previous
five years shall result in a revocation
of the certificate of six months.
d. More than three offenses within the
previous five years shall result in
permanent revocation of the certifi-
cate.
(AO No. 96-98(S), $ 8, 8.13-96)
Supp. No. MA 1 AMC 15.55-10
Municipality of Anchorage e
-./ Development Services Department
l
Building Safety Division
\ _ On -Site Water and Wastewater Program S I 1
4700 South Bragaw St.
P.O. Box 196650 Anchorage. AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904iilZ�•�/AWw(d
CERTIFICATE OF HEALTH AUTHORITY APPRZVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051.832-01
1. GENERAL INFORMATION
HAA# YA O 11D 43 q
Expiration Date: 11-1-7-01
Complete legal description Lot 8 Block 3 Toniess Estates Subdivision
Location (site address or directions) Tony Circle
Current Property owner(s) MMBM Contracting Day phone 688-1236
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing Address
P.O. Box 670495 Chugiak AK 99567
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class _ Well
Public Water System
Three 3
Day phone
Day phone
TYPE OF WASTEWATER DISPOSAL:
®
Individual On-site
El
❑
Individual Holding tank
❑
❑
Community On-site
❑
p
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with
valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public
water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional
engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm _Anderson Engineering Phone 5227773
Address P.O. Box 240773 Anchorage, AK 99524
Engineers Printed Name Michael E. Anderson, P.E. Date 8111/2001
O . M161P°_. E ANDEMN . s�
�o^%n•. CE -4321 �•\��10
5 DSD SIGNATURE ®,�• ••,•�Fw
......• �. a
Approved for _,bedrooms. 68ea &j,%FEESSS 9��0
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
Attachments:
HAA Checklist X
Septic System Advisory
Well Flow Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
By: ! //�� /!� / — a Original Certificate Date:
(Rm. 77!00)
Municipality of Anchorage •.
' Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Banc 196!350 Anchorage, AK 99519.6650
www.ci.anchorage.ak.us
(907) 343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: Lot 8. Block 3. Tomes: Estates Parcel ID: 051432-01
A. WELL DATA
Well type Private
Date completed _
Total depth ft.
Date of test
Static water level
Wen production
If A, B. or C provide PWSID #
Sanitary seal (YIN)Y
Cased to >40 ft.
FROM WELL LOG
WATER SAMPLE RESULTS:
ft.
Well Log (YIN) N
Wires properly protected (YIN) Y
Casing height (above ground) >24 m.
AT INSPECTION
72911M
91 fL
g.P.m. .4 g.p.m.
Cdnarrn 0 cotanies/100 mi. Nitrate 2_7 mg.A.
Date of sample: 7292001 Collected by: hake Andemon
B. SEPTICIHOLAING TANK DATA
Other bacteria 0 colonies/10D ml.
Tank Type/Material SeWdSteel Date installed 4!112001
Tank size 1.000 gal. Number of Compartments a Cieanouts (YIN) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N
-,Dat9 of pumping Pumper New constmction
c. ABSORPTION FIELD DATA
Date kutalled 41122001 Son rating (g p.d W or fe/bdrm)12 GPDISF System type Deep Trench
Length 40 ft. Width 3 ft. Gravel below pipe 5 ft.
Total depth 10.5 ft. Eft. absorption area 400 ft° Monitoring tube Y Depression over field N
Date of adequacy test Results (Pass/Fall) For _ bedrooms
Fluid depth in absorption field before test _ in. Water added_ gal. New depth_ in.
Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >= g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N 6 type) N It yes, give date
D. UFT STATION
Date installed
`Pump on' level at —in.
Datum
Size in gallons
'Pump off" level at _ In.
Cycles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tankAtft station on lot MW
Absorption field on lot AW
Pudic sewer main WA
Sewer /septic service line >25!
Manhole/Access (YIN)
High water alarm level at in.
Meets alarm b circuit requirements?
On adjacent lots MW
On adjacent lots AW
Public sewer manhole/deanout WA
Holding tank WA
SEPARATION DISTANCES FROM SEPTICIHOLDING TANK ON LOT TO:
Building foundation >S Property line >9 Absorption field >8
Water main WA Water service line >10' Surface water MW
Wens on adjacent lots AW
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line Mir Building foundation >10' Water main >10'
Water Service tine >10' Surface water >1W Driveway, paftvlvaNda storage MV
Curtain drain None Noted Wens on adjacent lots >1t10'
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I cer* brat I have determined ttuougb held inspections and
review of Municipal records that tire above systems are in
conformance with MOA HAA guidelines in effect on fttis date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 6l`11=1
HAA Fee E J00 Oe Waiver Fee $
Date of Payment 8 - /_? - n I Date of Payment
Receipt Number g / �r Receipt Number
(Rev. 12r00)
o%P;: A
pQ.gRIpERSCN•'V
YYtt 77JJll��EECC
PRO F E SSti�N� .►•�
Municipality of Anchorage ••,
Development Services Department
Building Safety Division ., ...
On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
Water Well Advisory
Health Authority Approval # 010439
During a recent Health Authority Approval on-site inspection and test of the
potable water supply well on Block 3, Lot 8 of Tonjess Estates subdivision,
the well's productivity was determined to be .4 gallons per minute. The
minimum well productivity required by this Department (AMC 15.55) for a
3 -bedroom residence is .3 gallons per minute. Although the subject well
currently exceeds this minimum requirement, all parties concerned are
advised that the production capacity of the well may fluctuate. Restriction
of non-critical water uses such as washing cars and watering lawns and
gardens may be required.
This advisory must be attached to all copies of the subject Health Authority
Approval.
CUE Environmental Services Inc.
L E . --_--
CT&ERef.#
1014764001
Client Name
Anderson Engineering
ProjectName/#
Lot 8 Blk 3 Toniess Est
Client Sample ID
Lot 8 Blk 3 Tonjess Est
Matrix
Drinking Water
Ordered By
PWS1D
0
Client PO#
Printed DateMme
08/03/2001 16:31
Collected Daterrime
07/29/2001 14:15
Received Datelrime
07/30/2001 8:10
Technical Director
Stephen C. Ede
-0yn
Released By
%%
�7�tF"`'"' `
Sample Remarks:
Parameta Results
PQL Units Medwd
Allowable
Iimits
Prep Analysis Init
Date Date
Waters Department
Nitrate -N ' 2.70
0.500 mg/L EPA 300.0
(<10)
07/30/01 SCI
Microbiology Laboratory
Total Coliform 0
0 col/I00ml. SM199222D
(<I)
07/30/01 KA