HomeMy WebLinkAboutJOHN WELLS 1952 ADDITION BLK 5 LT 15John Wells Block 5 Lot 6&15 x'014-261-23 Vie' - ! MUNICIPALITY OF ANCHORAGE e • DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION ' \\ 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME _ NEW MAILING ADDRESS PGRADE �s LEGAL DESCRIPTION rJ Lo/ /S I3/.E S ✓ol,�scl�!/.5/c,.�•csT�a�S�Le! LOCATION Ta...E L�e%r:�/%y. s c e.,. G /$ T crse�. o L G NO. OF BEDROOMS � y 3 Well Absorption area DISTANCE TO: O Dwellin f�t PES IIT NO. 2 Y LuQ EManufacturer'�Material No. of compments apacity in gallons Inside length Width OG IF HOMEMADE: Liquid depth dtlZ DISTANCE TO: Well Dwelling • PERMITNO. I?F Manufacturer • Material Liquid capacity inga Ilons m= Well Nearest lot hna DISTANCE TO: /� 2 Foundation PERMIT NO. LL Z 2 W ~ No, of lines Length of each line Z e Total length of lines Trench width Distance lines m t- Top of tile to finish rade ¢� Material beneath tile inches Total effective absorption o Len lh 9 Width Z"� inches Depth area Z Ba W (7 PERMIT NO. Q 9!: S W Type of crib Crib diameter Crib depth Total affective absorption area h DISTANCE TO: Well Building foundation Nearest lot line J J Class Depth Driller Distance to lo[ line PERMIT NO. W DISTANCE T0: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS C.Z. -0"4Js1r%%/,S�i� >✓rOi SOILTEST RATING �[ ` INSTALLER REMARKS W. 0- / u ' r��u.�c�yr�"t PALP '1ZRA E A ... • r -"T. sF.. +I`Qobuls , ;g( ENVIE ,:'!' %. 1 .O.I `TI - .7 f S% He. 151" 411' '• t � t '�•.+ mow•' 9 APPROVED DATE LEGAL 72-013 (Rev. 3178) rl r_r r•.1 I I: I r'" L- I T Y r--1 F= F=t r-4 1Y F-1^_ F=l r E. DEPARTMENT L. HEALTH AND ENVIRONMENTAL PROTECTION 225 'L' STREET, ANCHOPAGE, AK. q?-Ol 264-4720 Or -a -S I TE == El•JEE PEF?r1 I T PERMIT NO. ( 220229 ) APPLICANT MIKE GILLILAND 2337 E 26TH COURT LOCATION 349-1140 LEGAL L15 B5 JOHN WELLS HOMESTEAD LOT SIZE 8550 SGUAF.E FEET TYPE OF SOIL ABSORPTION! SYSTEM IS: TRENCH MA{IMUM NUMBER OF BEDF:OOr•1S = 3 SOIL RATING (SO FTtBR)= 85 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: C-EF•TH= 1r=+ 2! • r3pnVaL OEFTH= S THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OF. DRRINFIELD. THE DEPTH OFA TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATIO14 (IN FEET). THERE IS FJO SET WIDTH FOP. TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION (IN FEET). REr�[J I RELY SEF}T I rC TFr"i-< S I .-E= 14=+r=iL+ r3FiLLQttE PERMIT APPLICANT HAS THE RESPONSIBILITY TO INFORM THIS DEPARTMENT DUPING THE INSTALLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY AND THE NUNCEP OF RESIDENCES THAT THE WELL WILL SERVE. --- Tl•!r c 2 > I r4SF�E0-T 10 N!E: FIRE F:ErLJ I RELY BACKFILLING, OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEFENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET RND TO A COMMUNITY SEWEP.. LINE IS 75 FEET. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS FIND CONSTRUCTION DIAGRAM_ ARE AVAILABLE TO INSURE PROPER INSTALLATION. F•ERrl I T E`�P I RES L1ECEr1EEF = �r 1c,� I CERTIFY THAT 1: I AM FAMILIAR WITH THE P.EQUIREMENTS FOP. ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 2: 1 UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INC ?E MORE THAN 2 BEDROOMS. SIGNED: R DANT MIKE GILLILAND ISSUED BY� 1 / � ---------- TE ----- 52 V4. 0 n n X SOILS LOG �\ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION TEST 825 L. Street, Anchorage, Alaska 99501 2644720 s� / SOILS LOG - PERCOLATION TEST PERFORMED FOR:�L!/,C$ rrC�/LL/GfJ.i_/l7 / DATE PERFORMED: E�� j!7 LEGAL DESCRIPTION: L D�ISs%.✓r o�7yr j /%,��„� J��L' DEPTH SLOPE SITE PLAN 1 2- 3 3 �14 1 - 5 A 6 7, . .n 8 / ,f�r7dv c;or�VC� 9 / v WATER ENCOUNTERED? 1116 �2 IF YES, AT WHAT 13 DEPTH? 14- 15- 16- 17- is- 19- en 415 16 171819en L Reading Date Gross Time Net Time Depth to Water Net Drop J PERCOLATION RATE_ TEST RUN BETWEEN PERFORMED BY: --Tec ;r Q CERTIFI 72-006 (6/79) 5r0189jo7 • Municipality of Anchorage `'� °`; &� On-Site Water&Wastewater Program ` (907)343-7904 a- AN 2 4 201 '' -m ='I7 �f T ti �6 4, c>h CERTIFICATE OF ON-SITE SYSTEMS APPROVA 01 6 $ L9 Parcel I.D. 014-261-23 Expiration Date: 1. GENERAL INFORMATION Complete legal description JOHN WELLS 1952 ADDITION;BLOCK 5,LOT 15 Location (site address) 2337 EAST 86TH COURT`ANCHORAGE,ALASKA 99587 Current Property owner(s) DANIEL BROKAW Day phone 540-2337 Mailing address 2337 EAST 86TH COURT ANCHORAGE,ALASKA 99587 Real Estate Agent Day phone 2. TYPE OF DWELLING: is Single Family(w/wo ADU) ❑ Duplex ❑ Multiple Dwellings(Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well U Individual On-site Individual Water Storage 0 Individual Holding tank ❑ Community Class Well El Community On-site ❑ Public Water System 0 Public Sewer ❑ WaiverNariance request for. N/A Distance: - Received by: / `— Date: 2'0A COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee$ 5A-Co Waiver Fee$ Date of Payment I ! WS7E' Date of Payment Receipt Number C)CJnvReceipt Number COSA# aGJC-ii/02(o Waiver# • • 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are)safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are)in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP,Ltd. Phone 337-6179 Address 3701 E.TUDOR ROAD,SUITE 101 "ANCHORAGE,AK,99507 Engineers Printed Name JEFFREY A.GARNESS,P.E. Date //Zit/0 Engineer's Comments: In conducting this evaluation,GEG provided an engineering evaluation of the well and/or septic system in accordance with the _.,40k\\\\%, guidelines and regulations established bythe Municipality ofAndw2geand industry practices.The reported resulsdescribe the ♦♦., ♦♦ condition of the systeMs on the date's of the evaluat on.Separation distances were measured to readily identifiable features Hidden defects or encroachments may exist that were not identified during the evaluation.The operational hie of all wells and septic ♦ • d,• 1� systems depend on a variety of variables including,but not tinted to,soil conditions,groundwater levels pal may fluctuate during • *t the year),quality of construction(materials and workmanship),and the water usage of the/army Wiring the system's / �c These 4: 4 0 conditions can vary,and are outside the control of GEG.Satisfactory test results do not guarantee • future performance of the % • system's;therefore,GEG makes no warranty(express or implied)regarding the Mum performance of the well or septic system. GEG makes no representation whether an alternative wet or septic system can be installed on the property the event either of Cie `% y • anent systems fad.The content of this report is for the sole benefit of the persooparty who retained GEG.Reliance upon the e1''fr A. GI•T es .�a4rr to information provided in this report by any other person or party,including but not limited to subsequent property purchasers,is not •:• -79 3 .' i authorized.In short,GEG disavows any legal duty to anyone other than the person party who paid forthis report. ♦�J J 6. DSD SIGNATURE ,,PROFESS ..• #AECC884 ,� System#1 Approved for LICENSE \\\\* bedrooms. y OF'q`�i.. ��� System#2 Approved for bedrooms. Q '7 O Disapproved. J ON-S1TE WATER AND Z Conditional approval for bedrooms,with the following stipulatigps: WASTEWA-(ER O; J v` S t c. ��c.vl�C Z Co e01(rs („(Jl,,j�'� GRAM 4 ii .Stt civ- O C T (r - . i S ZOO `M'SER\I\G By. - > Original Certificate Date: 1 2G.- 1 e • The Municipality or Anchorage Develop,emt Services Division(DSD)issues Certificates of On-Site Systems Approval(COSA)based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist _ Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other (Rev.10112112) If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: JOHN WELLS 1952 ADDITION; BLOCK 5, LOT 15 Parcel ID: 014-261-23 A. WELL DATA 'PER GEG INSPECTION "ASSUMED BASED UPON MOA TAX RECORDS Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) NO Date completed **1956 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth *92.1+ ft. Cased to UNK ft. Casing height (above ground) 12+ in. FROM WELL LOG AT INSPECTION Date of test 1/11/2018 OG Static water level �0-L�' ft. 63.2 ft N� Well production g.p.m. 4.8+ g.p.m. WATER SAMPLE RESULTS: Coliform N'✓CS colonies/100 ml. Nitrate N7 mg./L. Collected by: GEG, Ltd. Arsenic: '35•Co ug./L. Date of sample: 1/11/2018 B. SEPTIC/HOLDING TANK DATA *36 YEAR OLD STEEL SEPTIC TANK IS APPROACHING THE END OF ITS USEFUL LIFE **FCO LOCATED INSIDE HOUSE PER 2005 COSA BY CINDY W ELLIS.P E. Tank Type/Material SEPTIC/STEEL Date installed 5/17/1982 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (Y/N) **YES Depression over tank (Y/N) NO High water alarm (Y/N) N/A Date of pumping t a I a 9 1 ( 4 Pumper n)W.V41 ( ,i(/ C. ABSORPTION FIELD DATA !'BELOWEXISTING GRADE ATSUMP' Date installed 5/17/1982 Soil rating (g.p.d./ftor /bdrm 85 System type DEEP TRENCH Length 24 ft. Width 2 ft. Gravel below pipe **6 ft. Total depth 12.1+ ft. Eff. absorption area 288 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 1/11/2018 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test ***0 in. Water added 481 gal. New depth 2 in. Elapsed Time: 92 min. Final fluid depth 0 in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date - • **PER THE 1982 INSPECTION REPORT THERE IS ONLY 2"OF EFFECTIVE DEPTH. HOWEVER,THE DESIGN STATES 6 FEET OF EFFECTIVE, AND THE "TOTAL EFFECTIVE ABSORPTION AREA"REFLECTS THIS. • ***SUMP EXTENDS APPROXIMATELY 5.5' BELOW IN THE INVERT OF THE LATERAL D. LIFT STATION Date installed Size in gallons Manhole/Access(Y/N) "Pump on" level at in. "Pump off level at '• a er alarm level at in. _ . •• Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot .5,6+ On adjacent lots "90'+ Absorption field on lot 100'+ On adjacent lots "100'+ Public sewer main 75'+ Public sewer manhole/cleanout 100'+ Sewer/septic service line 25'+ Holding tank 75'+ Animal containment areas 50'+ Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 54- Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots *70'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'4- Curtain 0'+Curtain drain NONE KNOWN Wells on adjacent lots *90'+ F. COMMENTS 'WR#050029"PER CINDY ELLIS, P.E.WAIVER REQUEST DRAWING IN MOA RECORDS DATED 5/14/2005 **visas*,, G. ENGINEER'S CERTIFICATION •'< :•••''' /***'.... ••j I certify that I have determined through field inspections and * : ;9'1' review of Municipal records that the above systems are in • v • • conformance with MOA COSA guidelines in effect on this i - . 1 • date. 10 0; J.f �,, •. Ga Hess f •53 Engineer's Printed Name JEFFREY A.GARNESS •�11�FQ...1 2y..... • C '• .4� /'ROFEssw': '• Date / LICENSE ,*I % %1#1' #AECC884 (Rev.10/12/12) Municipality of Anchorage •; i� Development Services Department Building Safety Division ' e 0 5 E f Y On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Arsenic Advisory Certificate of On-Site Systems Approval # OSC 181026 A Certificate of On-Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 5, Lot 15 of John Wells 1952 Addition Subdivision. This inspection revealed an arsenic concentration of 33.6 micrograms per liter (ug/L) for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Information on arsenic is available from the On-Site Water and Wastewater Program website (www.muni.org/onsite) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On- Site Systems Approval. !� Municipality of Anchorage On -Site Water & Wastewater Program (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 014-261-23 1. GENERAL INFORMATION Expiration Date: " Vl L3 Complete legal description JOHN WELLS 1952 ADDITION; BLOCK 5, LOT 15 Location (site address) 2337 E. 86TH COURT *ANCHORAGE. AK Current Property owner(s) ANGELA CARTER Day phone 541-698-7916 Mailing address 2337 E. 86TH COURT *ANCHORAGE. AK Real Estate Agent TRACY WILLIAMS W/ KELLER WILLIAMS Day phone 350-4482 2. TYPE OF DWELLING: E Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 2 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ Received by: Date: I / COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 7`70% Waiver Fee $ Date of Payment ��/� Date of Payment / Receipt Number Receipt Number COSA # Q15Cl3 /15-3 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, UD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the. system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of ail wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever 6. DSD SIGNATURE System #1 Approved for V1 bedrooms. System #2 Approved for Disapproved. Conditional approval for 0 bedrooms. Phone 337-6179 Date 23 (3 bedrooms, with the following stipulations: OF CE— •�� 23. 13 ,,Pro f es sio�S< OFiVC(ire ON-SITE imp WATER AND ? WASTEWATER; Original Certificate Date: The AruniciialitlbAAnchorage Develop, emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other (Rev. 11M) If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: JOHN WELLS 1952 ADDITION: BLOCK 5 LOT 15 ParcellD: 014-261-23 A. WELL DATA *PER CINDY ELLIS, P.E. **PER SURROUNDING WELL LOGS (WELL LOGS ALREADY FILED WITH MOA) Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) NO Date completed 1956 Total depth *186 ft. Sanitary seal (Y/N) YES Cased to **40+ ft. FROM WELL LOG Date of test NO WELL LOG Static water level ft. Well production g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Nitrate ND mg./L. Arsenic: 25.2 ug./L. Date of sample: 4/5/13 B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Tank size 1000 gal. Number of Compartments E Wires properly protected (Y/N) YES Casing height (above ground) 12+ in. AT INSPECTION 4/13/13 ,:1/1 4.1 Collected by: GEG. Ltd. Date installed 5/17/82 Cleanouts (Y/N) YES Foundation cleanout (Y/N) YES Depression over tank (YIN) NO High water alarm (Y/N) N/A Date of pumping 4/5&19/13 Pumper A+ HOME SERVICES S tit: (UoM'11y+J'0 C. ABSORPTION FIELD DATA Date installed 5/17/82 Soil rating (g.p.d./ft`or /bdrm 85 System type TRENCH Length 24 ft. Width 2 ft. Gravel below pipe 6 ft. Total depth *12.16 ft. Eff. absorption area 288 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 4/13/13 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test 0 in. Water added 450 gal. New depth 0 in. Elapsed Time: 0 min. Final fluid depth 0 in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE If yes, give date — D. LIFT STATION Date installed "Pump on" level at in. Size in gallons Manhole/Access "Pump off" level High water alarm level at in. Cycles tested Meets alar & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot *55'+ On adjacent lots *90'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main 75'+ Sewer /septic service line 25'+ Animal containment areas 50'+ Public sewer manhola/cieanout 100'+ Holding tank Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Properly line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots *70' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots *90' F. COMMENTS *WR#050029 G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSH guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date � f/23 !13 (Rev. 11/05) Municipality of Anchorage RG Community Development Department Development Services Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Arsenic Advisory Certificate of On -Site Systems Approval # 131153 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 5, Lot 15 of John Wells 1952 Addition Subdivision. This inspection revealed an arsenic concentration of 25.2 micrograms per liter (ug/L) for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Information on arsenic is available from the On -Site Water and Wastewater Program website (www.muni.org/oqsiLe) or at 343-7904. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. Municipality of Anchorage • Development Services Department +� ` Building Safety Division On -Site Waterand Wastewater Program ` 4700 South Bragaw St. '" `• P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 014-261-23 1. GENERAL INFORMATION Complete legal description John Wells Block HAA# rSG�`1L;S Expiration Date: 8.11241r - Lots 6 & 15 Location (site address or directions) 2337 E. 86th court, Anchorage. AK 99507 Current Property owner(s) Darwin Sprinkle Day phone 344-1403 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual Well El Individual Water Storage ❑ Community Class Well ❑ Public Water System ❑ Day phone Day phone TYPE OF WASTEWATER DISPOSAL: Individual On-site 21 Individual Holding tank ❑ Community On-site ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate forthe number of bedrooms and type of structure Indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and Inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Watkins Engineering. Inc. Phone 349-1851 Address P.O. Box 110443, Anchorage, AK 99511-0443 Engineer's Printed Name Cindy W. Ellis Date 5''05 5. DSD SIGNATURE ✓ Approved for 3 bedrooms. v Disapproved. Conditional approval for bedrooms, with the following 10Y W. Ellis CE. tosn Attachments: HAA Checklist X Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other By: Original Certificate Date: -:5-118 o f xRa. 011M Municipality of Anchorage Development Services Department Building Safety Division On-Sne Water 6 Wastewater Program 4700 South Bragaw SL P.O. Box 196550 Anchorage, AK 99519.6850 www.muni.org/onske (907) 943-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: John Wells 81k 5 Lots 8 a 15 Parcel ID: 014-261-23 A. WELL DATA Well type RI If A, B, or C provide PWSID 0 Date completed 1958 Sanitary seal (YIN) N Total depth 186 fL Cased to 166 ft. FROM WELL LOG Date of test NA Static water level NA ft. Well production NA 9— p.m-WATER SAMPLE RESULTS: Coliform colontes/100 ml. Nitrate 10A mg.A. Arsenic: NA mg.A. Date of sample: 12M B. SEPTICIHOLDING TANK DATA Tank Type/Material steel Tank size 1000 gal. Number of Compartments 2 Well Log (YAC N Wires properly protected (YIN) Y Casing height (above ground) 12 in. AT INSPECTION 5-305 63 ft. 4.2 g.p.m. Other bacterial I �es/100 mi. Collected by: C. Ellie Date installed 317-82 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y_ Depression over tank (Y/N) N High water alarm (Y/N) NA Date of pumping 5/3/05 Pumper Northland Pumping C. ABSORPTION FIELD DATA Date instaned 5-17-82 Son rating (g.pd.Atz or f?Axtnn) 85 Length 24 Total depth 76 ft. ft. Width 2 ft. System type deep trench Gravel below pipe 6 ft. Eft. absorption area 288 if Monitoring tube Y Depression over field N 5.3-05 Results ass/Faip Pass For 3 bedrooms Data of adequacy test (P — Fluid depth In absorption held before teste•5 In. Water added 4tT6 gal. New depth 5.25 in. Elapsed Tlme: 17 min. Final fluid depth " in. Absorption rate >= 450 g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N 6 type) none known If yes, give date D. LIFT STATION Date installed NA 'Pump on' level at _ In. Datum size in gallons 'Pump oft' level at_ in. Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank(fift station on lot 57 (mer raq•) Absorption field on lot 102 Public sewer main 100+ Sewer /septic service line 44 Manhole/Access (Y/N) High water alar level at in. Meets alarm 6 circuit requirements? On adjacent lots 91 (waiver requested) On adjacent lots 100 Public sewer manhole/cleanout 100+ Holding tank NA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 14 Property fine 27 Absorption field 39 Water main 100+ Water service line 25+ Surface water 100+ Wells on adjacent lots 72 (waivr net) SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 30 Building foundation eo Water main 100+ Water Service line ro+ Surface water 100+ Curtain drain none known Wells on adjacent lots 00"m O F. COMMENTS FCO is inside the house. Waivers requested for G. ENGINEER'S CERTIFICATION 1 cerBly that 1 have detemtlned through field inspecfions and review of Munlapal records that the above systems are in conformance with MOA HAA guldefines in effect on thle date. Engineer's Printed Name Cindy W. Ellis Driveway, parkingivehicle stotage 60+ distances. 0 Nly W. Ellis CE.1057 Date 5 -14 -05' - HAA Fee E 143y CD Waiver Fee $ Date of Payment S%l X105— Date of Payment Receipt Number 6n 8S Receipt Number (Rev. 12/01) Client Name Project Name/U Client Sample LD Matrix 01 Watkins Engineering John Wells Blk 5 Lot 15 John Wells Blk 5 Lot 15 Drinking Water All Dates?Imes are Alaska Standard Time Printed Date/Time 04282005 13:19 Collected Date/Time 04252005 15:30 Received Dateff[me 04252005 15:59 Technical Director Stephen C. Ede Sample Remarks: Allowable Prep Analysis Parameter Results PQL Units htcthod Container [D Limits Date Date [nit Waters Department Nitrate -N 0.100 U 0.100 mg/L, EPA 300.0 B (<-10) 0425/05 WAW Kicrobiolomr Laboratory Total Coliform IOB. NoColi col/100m], SM209222D A (<-1) 0425/05 TL.F /i / SCS Ref.# Client Name Project Name/# Client Sample ID Matrix Sample Remarks: 1052339001 Watkins Engineering John Wells L16.B5 John Wells L16,B5 Drinking Water All DatesR7mes are Alaska Standard Time Printed Date/Time 05/09R005 12:42 Collected Date/rime 05/03R005 13:00 Received Datc)TIme 05/03/2005 14:40 Technical Director Stephen C. Ede Allowable Prcp Analysis Parameter Results PQL Units Method Container ID Limits Date Date Init Waters Department Nitrate -N 0.193 0.100 Microbiology Laboratory Total Coliform 0 mg/L EPA 300.0 B (<-10) 05AW05 JJB coV100mL SM209222B A (o-1) 05/03/05 TLF 05-11-05 08:40AM FPCM-CT4E ESI, SGS ENV SERVICES SGSRrfJ 1052340001 CncntName Watkins Engineering ?elect NameN/ John Wells Blk 5 Lot 14 Client Sample ID John Wells Blk 5 Lot 14 Matrix Drinking Water Sample Remarks: 9075615301 T-675 P.02/04 F-828 All Dates/fines are Alaska Standard Time TrlatedDate/Time 05/092005 12:42 ColketedDateMaw 05/032005 14:00 Received Date/time 05/032005 14:40 Tethnkal Director Stephen C. Ede Anowuble Prop Analysis Panmear Results PQL Units McdMA COngir"tD Lanils Date Dole lois Waters Department Nivste•N 0.100 U 0.100 Microbiology Laboratory Total Colifunn 151 OB, No Coli mg/l. EPA 300.0 B (-10) 05/04/05 HE covioomL SN1209222B A (-1) 05/03/)5 TLI 1Q 7- se . 3 b r q ly t y V°S - _I I -,0- •6 I Gtv 2.4 It is the rapomibility of the owner to determine the exiuence of any easements, covenants or res rations which do rat appear on the recorded subdivisi n plot. Under no circumstances should any data he on be toad for consuWion or for establishing boun ary or fence lines. The surveyor takes responsibility for We initial trarnaclion only: fAeT 8414..Cou,-� 12 .OT/* $/Or BLOCK - S yr—� (PLAT NO.: _) 1NCHORAGE RECORDING DISTRICT DATE: BY: SCALE: I WORK ORDER: OF A�tL. : •,., .:..........._----- i cer Kurt .Dor1106 g ' s� •. ' 15d1S . tt, ARD••�SSIONAL���+` �� NOTES. ��\�iv►�� EASEMENTS OF RECORD. OTHER THAN THOSE SHOWN ON THE RECORDED PLAT. ARE NOT SHOWN HEREON. LEGEN .DRASS CAP MONUMENT" IRON PIPE REBAK'CORNER FOUND t7 I IUB AND TACK FIELD BOOK: GRIDNO.: .S d 'aS / ~ 30 • 0.s'-- m/2 � .l:A:�„ry 233 PREPARED BY: DOWLING & ASSOCIATES 1426 Hydcr Strcct r ANCHORAGE, AK 99501 REVISIONS DATE BY El A L A s K A 2005-032868-0 Recording Dist: 301 - Anchorage 5/18/2005 10:38 AM Pages: 1 of 2 COVENANT TO PROVIDE ACCESS The owner of John Wells Subdivision, Lot 6, Block 5, Darwin Sprinkle. grants ingress/egress rights to the owner of the adjacent lot, John Wells Subdivision, Lot 15, Block 5, Darwin Sprinkle C 1�C�0��th¢ pis�ric�- for the purpose dq, f maintaining the septic system serving Lot 15, which is located on Lot 6. The allowable area for ingress/egress is detailed on the attached site plan dated May 17, 2005. Signed on this date: —qh /Mg in Anchorage, A •a. Owner of Lot 6: ;" 1 1� Darwin Sprinkle (� r Owner of Lot 15: QJ1LG "J Darwin Sprinkle Notary Public in and for the Sate of Alaska: My Commission Expires: OFFICIALSEAL StateofAlaska MONICA HOWARD NOTARYPUBLIC n-•--- -- - - -I -I t•• . Lik i Based upon a survey by James Dowling, RLS 1564 May 5, 2005 IM ,F .J 1. .. ..V ... _... -. ., Lot 6 j Allowable area for ingress/egress septic I I I system trench' c Monitoring Z.c' I Tube ft - 10 1=� ` z' �= 1000 Gal Septic Tank Existing y House C'. _ Q� O M John Wells Blk 5, Lots 6 & 15 Site Plan for ingress/Egress for Septic System Maintenance Darin Sprinkle Parcel ID No. 014-261-23 Cindy W. Ellis, P.E. May 17,205 Scale 1 inch = 30 ft r l L� st 28 ft Lot 15 Watkins Engineering, Inc P.O. Box 110443 Anchorage, Alaska 99511-0443 Phone: (907) 349-1851, Fax: (907) 349-1934 I OF A -P"" ,........Cys A.!! .. (.i`L(u`•....... .': cl r�w Euls . E . +usn Municipaiiiy of Aiiciioi-age o ifet� P.O. Box 1961:5() • Anchorage, Alaska 1YA19.6650 • Telephone ('.107) 333-13801 • I'm 0)7) 33.1-82(M) 470011ragax Street • Anchorage, Alaska 9!1.507 `� xv�c.munLorg Mayor Nark Beyic/t Building Safbl3• Dix-lslon May 18, 2005 Cindy Ellis Watkins Engineering P.O. Box 110443 Anchorage, Alaska 99511 Subject: Waiver Request for John Wells Block 5 Lot 15 Waiver Request WR#: 050029 Parcel ID # 014-261-23 ITA/Permit # Dear Cindy Ellis: Your request for a waiver of the required 100 feet horizontal separation from the septic tank to private well has been approved. The approved separation distance is 55.0 feet. This waiver applies to Lot 15 Well to Lot 15 Septic Tank 55 foot Horizontal separation and Lot 15 Well to Lot 5 Septic Tank 90 foot horizontal separation This waiver approval applies to the existing septic tank to private well separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, Joodall i I Engineer On -Site Water & Wastewater Program Community, Security, Prosperity Aat TI/ Municipality of Anchorage Development Services Department Building Safety Division On•Sitc Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchorage.ak.us (907) 343-7904 Waiver Review Worksheet WR#:050029 PID#: 0 14-261-23 HA1Permit# 11A050205 Date Received: May 18, 2005 Legal Description: John Wells Block 5 Lot 15 Engineer: Cindy Ellis Watkins Engineering P.O. Box 110443 Anchorage, Alaska 99511 Applicant: Darwin Sprinkle Waiver Requested: Lot 15 Well to Lot 15 Septic Tank 55 foot Horizontal separation. And Lot 15 Well to Lot 5 Septic Tank 90 foot horizontal separation Criteria: Geology Points: A. Water Table 7.23 B. Soil Sorption 3.47 C. Permeability 2.51 D. Water Table Gradient 2.90 E. Horizontal Separation 1.2 Total:__ _ 17.311 .......................................................................... Waiver is Granted: X List Conditions or Reasons for above: Waiver is not Granted: Date: 5118105 By:J�G�all Name of Reviewer Red#: 87838 Amount: 3].la`t-Q Date Paid: 5/18/2005 State of Alaska: Separation Distance Waiver Guidelines for S.C.R.O. (State of Alaska Memorandum to District Office Engineers dated January 5,1985) Waiver Request for: John Wells Block 5 Lot 15 Parcel I D#: 014-261-23 Waiver Request Number WR#: 050029 Waiver Requested: Lot 15 Well to Lot 15 Septic Tank 55 foot Horizontal separation. And Lot 15 Well to Lot 5 Septic Tank 90 foot horizontal separation Engineer: Cindy Ellis IIA050205 Septic Tank Data The septic tank on John Wells S/D Block 5 Lot 6&15 was installed in 1982. The permit was issued by the Onsite department with a permission to place the tank with a 70' horizontal separation distance. However the tank was placed 55' away. Even with the permission by the department of 70' the tank would have encrouched other wells in the area in particular Lot 14 & Lot 16. The tank and leachfield installed in 1982 that encroached three wells has been in existence for over 20 years. Watkins Engineering took water samples for each of the encroaching wells. And all three tested with -in Municipal standards. :l-3110 11._ John Wells S/D Block 5 Lot 6&15 does not have a well log to be found. However Watkins Engineering during their Health Authority Inspection determinde the well to be constructed in 1956, a total depth of 186' with casing to 186', satic water at 63' and a flow rate of 4.2 gpm. And water samples tested to be 0 coliform, .1 mg/I nitrates, and 1 other bacteria, which is with -in Municipal standard. Other well logs in the area shows there is a confined aquifer with an impermeable layer of blue clay and hardpan at 40 ft to 140ft. Using averages and Lot 18 well log I determined 83 feet of impermeable layer. State of Alaska: Separation Distance Waiver Guidelines for S.C.R.O. (State of Alaska Memorandum to District Office Engineers dated January 1,1985) Waiver Request for: John Wells Block 5 Lot 15 Parcel [D#: 014-261-23 E� Waiver Request Number WR#: 050029 r•: ;r:,::c••,,•:Y,c .a s Waiver Requested: Lot 15 Well to Lot 15 Septic Tank 55 foot Horizontal separation. And Lot 15 Well to Lot 5 Septic Tank 90 foot horizontal separation Engineer: Cindy Ellis IIA050205 Water Table Points Depth of well: 152 7.23 Depth of septic system: 8 144 Distance from the bottom of the system to the highest water table In feet Point value 0 0 8 1 17 2 24 3 30 4 40 5 85 6 100 7 290 8 1000 9 + 10 • Straight line Interpolation Is permitted between any two values Soil Sorbtion Points ,13, 3.47 34 (144, 2.5 + [ 83 4.5 + 27 1.5 + 0 0 Soil Type I Point Valuel Clean Gravel 0 144, 144 144 Fractured Rock 1 Course Clean Sand 1.5 0 +1704-4-) 0+jI 0 0+ 0 0+ 0 Sand w/ Small Amt of Clay 2.5 144, l 144 ] 144 [1-04-4 , Silt 3.5 Clay and Sand Equal 4.5 0.6 + 2.6 + 0.3 + 0 Clay 6 0 + 0 + 0 + 0 *Use the predominant soil type but values can be averaged for a mixture PermeabititV Soil Type Point Value Clay(will channel) 0 Silt and Sandy Clay 2 Clayey Sand 3 Fine Sand 1.5 Sandy Gravel 1 Fractured Rock 0.9 Course Sand (30 grit) 0.4 Clean Gravel 0 Points ,,.I, 2.51 34 1, 3 + 144, 3 + l 144, .4 + f 27 [ 144, 1 +L 10 1 +r 10 1 + 144,1 +1144,1 0.71 + 1.73 + 0.08 + 0.00 0.00 + 0.00 + 0.00 + 0.00 *Use the predominant soil type but values can be averaged for a mixture Gradient 2.9 %Slope Points Value -60% 0 In Feet -30% 0.3 0 -20% 0.7 50 -10% 1.2 2 -5% 2 150 0% 2.91- .9}5% 5% 4.5 10% 6 60% 7 slopes toward well Oat slopes away from well *If the gradient is unknown, assume the wont case Horizontal Horizontal Point Separation Value In Feet 0 0 25 0.7 50 1 75 2 100 3 150 5 200 6 300 7 Points vs, 2.90 Points ,,.I, 12 *Linear interpolation between two point value Is acceptable. Horizontally means straight line distance to the well not the contaminate travel distance to water table which may be greater. Conclusion: Grant Waiver Total Points: 17.311 DATE: May 18, 2005 TO: FILE MUNICIPALITY OF ANCHORAGE Building Safety Division MEMORANDUM FROM: Joe Goodall Engineer II, 4ite Water Wastewater Program SUBJ: JOHN WELLS BLOCK 5 LOTS 6815 THE FOLLOWING WAIVERS WERE DONE WITH HEALTH AUTHORITY APPROVAL NUMBER HAO50205: (WR050029) - LOT 15 WELL TO LOT 15 SEPTIC TANK, 55 FEET HORIZONTAL SEPARATION DISTANCE. AND LOT 15 WELL TO LOT 5 SEPTIC TANK, 90 FEET HORIZONTAL SPARATION DISTANCE. (WR050030) - LOT 14 WELL TO LOT 6 SEPTIC TANK AND ABSORBTION FIELD, 90 FEET HORIZONTAL SEPARATION DISTANCE. (WR050031) - LOT 16 WELL TO LOT 15 SEPTIC TANK, 70 FEET HORIZONTAL SEPARATION DISTANCE. MONDAY 5/16/05, CINDY ELLIS, DAN ROTH AND I MET TO RESOLVE THE WAIVER ISSUES. I HAVE BEEN AUTHORIZED BY DAN ROTH TO APPROVE THE ABOVE WAIVER ASSOCIATED WITH THE HEALTH AUTHORITY APPROVAL HA050205 ..�.�•� 1� ♦ ,� � �]MI r r ..��' i' M .•. ��' /f ,� t, L+ I /i'� _ sem., _ice^' I�e 1 �`� tl��j,•• •ILJr ./_S ,: ,'•ric ., ;1 ,. i �. Ir T! � � _ fir''' 1 �� r ��'� ��'\ t� �1,r1 •, r .I r v� ./ ��7ti. __.�__ ' � � y�y1�� I�{5:..11�� ZfAIL1''� �`�•ti1y fit: r i •rl l w r �,�p� JJ / h • ly /1Jp rl J ,`�,. t �J -J.7 --.. =' 1 .=jam � ,iF +�Irt'�— �i f_1l,�T� � �V.1 �i'1•. 10 It V. } d ,Irk .. � j11.• ,{ . Tw--�n PIl�r•Y` a�♦ j ♦ { _ e"'T ` T -.. y y ,rte ,.. r , - , 4 1 . 1'.T / - •w I i � ��Tj7 !�{Slr.. .,\r < n • , I �I�' - � l r •Ib� rr . iil1, A.a JJ 1L ,I Jj� I ,.:� � r�rr. 1� ;')1..4 1 � !` f \• • / p J' _ + r . ' 1 r 1 ' 5' r y w. 'r ' f .v! <a l,� �.,,r J ,t� J • t \ � r 1 • �' 1 +.r , r t l • • .� 1 yc 'r � r y a / �)� y.IJ� r� i-i � _ — � '-y J\ l r •/r r lt+v t 7/ {I' t✓ „ t � ISS .. ��'t ter. ,, ws `V� i .• J -�-! H rt:/) /` Ir♦� I i IJ �• 1 r / •c\ Tr' 1.r �' r � YM - f tl , . r • r � ♦ -� 1 I' „ �.<.T. \C : 1. � r'V i f T - � I ;,: r +. � lit S! ^'• ` i :i%. .t i'4 ._ � _ r .. !, •r � !:i 41,♦ !—�,• 1 :Il �' -�Sln� �J f'1 VrH ,1 r. J1ll.r/ ,rr• a r_ lir i(' ••IJ .'4� ar+•:,l� .1 - r 1 ;its.!(! 1..•r.f i, �� r� r G— I 'J '''. r ,�. rr. .r ��, 11't, 7. .' F i V :• r'� ;%/ . � 1.::,• _'.' r I l •! ' rP'r,t �!� _S. i.+i. /./ i !r •i L i rJ �L Vit... ♦'J ♦f,♦1`�.J r{`.r r._T ., / .1- � � ��' �1 .i �'l 14 vp It o4 Al lk VL ZZ - • ,y • Y.If i,:qf. �• ., f��� � Int 'R 11 }1i , er t r �. �T f •ham " r A .. � if 'LC � 1' I � •• 1 1r l e 14�. /, t �'� I w •1 �, rT,. 1.:_� ♦ A.,�t � •..> 1• 1.' •� � ♦• T f 1 / .ri•... . •`• �� '�!. .IJP>> •Tt ."f• . �\ [.�� � .•. �. . I .. I•• r - i. t I .. (:'.'. )"V• J l.. �_\ '� _ 1. ri, -+1 s1' 1 • I ,� �.. - .• tom. '..�,►. T ' "tom �.r. •._ r_ V ...- �- .„�.;� - - .�'.. _ Watkins Engineering, Inc. P.0 Box 110443, Anchorage, AK 99511 (907)349-1851 cweliis@gctnet May 14, 2005 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 RE: John Wells SID, Block 5, Lots 6 815 Waiver Request for Septic System Wells To Whom It May Concern: The existing home on John Wells Bik 5 Lot 15 is served by a well on Lot 15 and a septic system on Lot 6, which was approved and installed in 1982. The original septic system was abandoned at that time. The house was built in 1956, and the well was drilled at that time. The adjacent home on Lot 16 has the well on Lot 16 and septic system on Lot 5, installed in 1974. The well and septic system for the house to the west, on Lot 14, are undocumented. We respectfully request a waiver for the separation distance from septic system components to wells, as follows: Lot 15 Well to Lot 15 Septic tank 55 ft Lot 15 Well to Lot 5 Septic tank 90 ft Lot 16 Well to Lot 15 Septic tank 70 ft Lot 14 Well to Lot 6 Septic tank and soil absorption system 90 ft Please see the attached site plan for locations of wells and septic systems. No well logs are available for Lots 14 and 15. There is a request for approval of the well and septic system for the Lot 15 (the subject lot) from the Greater Anchorage Bureau, showing the well at a depth of 186 ft. A copy of the request is attached. This depth was confirmed by the owner, when he changed out the well pump in about 1997. The well log from Lot 16 is attached, showing a depth of 154 ft. The soil descriptions of "silty gravel" are inconclusive as a barrier; however, the static water level of 70 ft indicates that this is a confined aquifer. Three other well logs from the area are attached, with well depths of 128 ft, 152 ft, and 162 ft. These logs show a layer of blue clay and hardpan at 40 ft to 140 ft. This layer of Impermeable silt creates a barrier, which protects the aquifer from septic effluent. This is substantiated by the low static fluid level in the Lot 15 well of 63 ft on May 3, 2005. Watkins Engineering, Inc., May 14, 2005 John Wells Blk 5 Lots 6 d 15 Waiver Request, page 2 of 2 Water samples were taken from the 3 subject wells, with results as follows: Well Sample Date Nitrates, m "Other" Bacteria, #/100 ml Coliform Bacteria, #1100 ml Lot 14 5/3/2005 Undetected 151 0 Lot 15 4/25/2005 Undetected 1 0 Lot 16 5/3/2005 0.193 0 0 The Lot 14 well is located in a pit, which is the probable cause of the "other bacteria" in the sample. Had there been septic effluent contamination, nitrates and coliform bacteria would be present. Wells on Lots 15 and 16 were clean. A site plan is attached showing ground level elevations at the septic system on Lot 6 and the three wells. The direction of flow at the surface from the Lot 6 soil absorption system would be down the driveway and into the street, rather than towards the well on Lot 14. The direction of flow from the septic tank would be into the basement of the house, before flowing towards the wells. This condition would be noticed and corrected quickly. Due to the forgoing facts, I believe that the proposed reduced separation distances would protect human health and the environment. Therefore, I recommend approval of this waiver request. Thank you for consideration of this request. If you need any further information, please call me at 349-1851. Sincerely, lei Cindy Ellis, P.E. President /Lot7 I \\ 24' x2' x 6 R e trench (1982) r� I i o I / 10pdGa1 o Greer Tank /19821/'� � i Ln n Lot 14 x Well I/ a I �0- 0-0 00O 0/6 00 Existing 3 I R O �/House O0O'o�JOE of C) !y OoOOOO a c I I OrD 0 0 j' / Lot 15 C1 w am O 3: E' OI' O O 1v Well v II OIDO OOl'' O O�O C�, / o c I0 0 OOC\ J._D 0 O ) O0 0. epage Pit Stacck, Steelp Tank Lost 86th Court \ Lot 27 N \� Lot 26 John Wells Blk 5, Lots 6 & 15 Watkins Engineering, Inc. o� �� •..... f_ q Waiver Request Darwin Sprinkle c,; 0 49 TM t�A .y• Parcel ID No. 014-261-23 'i'•':` :: Cindy W. Ellis, P.E. P.O. Box 110443 May 14, 205 Anchorage, Alaska 99511-0443 V.' Scale 1 inch = 30 ft Phone: (907) 349-1851, Fax (907) 349-1934 Lot 6103.97 I 103.7 ) Lot 5 a Lot 7 01 I ' -a t Seepage Pit (103.27 24' x2' x 6 ft eff. trench (1982) O °J 103.27 x E ifJ I 102.26 Slight knoll N i 103.05 at roe a' Stack Steel Tank CO line Q> i 10 9� 1018 cry 1000 Gal Direction of 100 75 Greer Tank x- 6 i surface flow 101.16 k x (1982) 100.6 Lot 14`g8 86 1Q0.65 X100.1 Well x 00.121 x� (in pit) _54 _ 100.48 - 99.47 99, _0 0°O° 1W I �-1Wj ° O ° Basement Direction of 0 O o c, 0 0 0 E ; surface flow 00 g 31 ° 00. 1 0 0 rn g� 96.93 000 ° ° X98. CL d x 96.8 0 ° 0 8:60, 98.99 Lot 15 98. o� ec o I o 0 0 0 °O U Well Lot 16 Well pi O°0 O°0 -- J'-� 000 _ 000 Last 86th Court 95.87 CR6.393 x--- ------------- - 95.26 ---------------- Lot 27 I — Fenchmark evations - ground leve nt door threshold = 100 00 I �Ia� r� l N I Lot 26 John Wells Blk 5, Lots 6 & 15 Waiver Request- Elevations Darin Sprinkle Parcel ID No. 014-261-23 Cindy W. Ellis, P.E. May 14,205 Scale 1 Inch = 30 R Watkins Engineering, Inc. P.O. Box 110443 Anchorage, Alaska 99511-0443 Phone: (907) 349-1851, Fax: (907) 349-1934 M -W DkILLING, Inc. P. O. Box 4-1728 • 2811 Dawson A C 907-279-1741 ANCHORAGE, ALASKA 99509 DRILLING LOG Well OwneUse of Well Location (address of: Township, Raqge, Section, if known; or distance main roars In{ I(.. AI S . jbfw W I//n r Size of casing S nepth of Hole 1.. feet Cased to eet Static water leve t. '(above) (below) land surface. Finish of well (check one) open end.( ) r Screen ( ); Perforated Describe screen or perforatio^ =='" Well pumping test at gallons per (hour) (minute) for hours with 1- fL of drawdown from static level Date of completion - WELL LOG To— To— To- -TO- To— To— To- 2—State OTOTOTOTOTOTO 2—State Figure 10 Depth in feet from ground surface Give details of formations penetrated, size of material, color and hardness .lyW- 11CC •� TO • - s ('rvr+ �oo.'E C3'F:IUf_ L J TO '•' SO .t" r rs1• �c�E,EEScE Ci/%f(/EL-: S/!7� TO e« C, •eBLE$l /SD t . r..,t, S/GTi/CIGCLI P/fifGG <'� TO ,C�•f t •• : , . . a _, _ _„ _ �H�ivA 4T.rVE.. ' ¢.se D W i17Y_?1 EEw(k//Joh TO To— To— To- -TO- To— To— To- 2—State OTOTOTOTOTOTO 2—State Figure 10 �� APPLIC NT FILLS OUT UPPER HAI CONLY A � �.A yOwner ;f 6/ eE'N hone Phone Maning Address/ S 117 �Yi c: 3J Buyer Date � Inspector Address Zip Code Inspecl8r, 1 117(./.Inn Lending Institution Phone Address 21p Code I��, Realty Co. d Agent c! 4/-, Phone Address /- J, ;..L_ J. –A Code EI.(I/IROti`A=IJTAL Legal Description/ -o ,Zip /S ¢ �+ ..y.—� O y✓ W Ir L �, S✓ ¢� T O J Street Location _ RECEIVED Type of Residence Z P-19Ingle Famlly Z ( '3) APPROVED BEDROOMS ❑ Multiple Family ❑ No. of Z rooms Other DATE ,G ; Water Supply BY:+ Solis Rating ,�Indlvldual Well To Absorption Area ATTACH WELL LOG. A well log Is required for all wells drilled slnce June 1975. mmunity ❑ Public Utility For wells drilled prior to that date, give well depth (attach log If available). Sewer 13PosaI ndivldmi Year Individual Installed: Public Utility ❑ Holding Tank When Connected to Public Utility: NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REOUEST BEFORE PROCESSING CAN BE INITIATED. 1VIA11_ T!n f , T ime Time Time Time Date Date Data Date � Inspector Inspector Inspecl8r, 1 117(./.Inn InspI or c'111S. I��, Field,�Nf7otos: 'y -k-0 , MUNICIPALITY OF H`-AL, CEPT. PROgo TECTION EI.(I/IROti`A=IJTAL OCj 1 `Z ri�� RECEIVED ( '3) APPROVED BEDROOMS *CONDITIONS OF APPROVAL ( 1 DISAPPROVED ( ) CONDITIONAL #PPROVAL- 2 647✓ DATE ,G ; BY:+ Solis Rating Date Sewer Installed Well To Absorption Area Well Log Received Well to Tank Septic Tank Size Al Time Time e Date Date Date Inspector Inspector Inspector Comments Conditional Approval �uu4L S. FL.4y.� 4J�- Q U - ' Date Sewer Installed Permit No. Septic Tank Size O cd '� / Holding Tank Size Solis Rating Well To Absorption Area Well Log Received Well to Tank APPLICANT FILLS OUT LOWER HALF ONLY Property Owner s r-! I phone Mailing Address 0j?7 $(y'�4 �, ( 1V1C�.1. ��. g9e0% �l 349 L10 Buyer Address Lending Institution Phone Address Realty Co. 6 Agent -,-;,Fk I •FttC1 Phone ,E.LC-qI yCn Address H—C. • 332Z _ DJTI Legal Description PyrCr S I S. john (,JCLLS L, Street Location Type Residence Single Family 3 ❑ Multiple Family No. of Bedrooms ❑ Other Water upply Individual ATTACH WELL LOG. A well log is required for all wells drilled since June ❑ Community 1975. For wells drilled prior to that date, give well depth (attach log If ❑ Public Utility available. SewapB Disposal L] Individual Year Indlvidual Installed: ❑ Public Utility When Connected to Public Utility- ❑ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received ✓ : ;U Time of Inspection // : 0 0 /I.li?• l� Date Inspection of REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES /FOR 1. Approval requested by: C. MIC-Akfl-L-L0-71"1 L%LJn Mailing Address: Phone: 2. Property Owner: Phone: Mailing Address: 3. Legal Description: Cat 6d iS �l�t{ �C�I<LL4 G/ 4. Location: l 5. Type of facility to be inspected Sr a No. of bedrooms 3 6. Well Data: A. Type B. Depth J'?�7 C. Construction Cel . rc_,{ D. Bacterial Analysis 7. Sewage Disposal System: A. Installed B. Installer V C. Septic Tank: 1. Size Itz'--t 2. Manufacturer jj'r. D. Seepage Pit: 1. Absorption Area lllt— 2. Material Z',, .'v e.,,,, -f V E. Disposal Field: Total length of lines 8. Distances: A. Well to: Septic tank 9 r , Absorption area Sewer Lines Nearest lot line /�� Other contamination B. Foundation to septic tank Absorption area >u r C. Absorption area to nearest lot line ;?c EQ -034 (1/74) Page 1 of two pages r�kEATER ANCHORAGE AHLA BOR�H Department of Environmentdl Quality 3330 "C" St., Anchorage, Alaska 99503 - 274-4561 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES 1. Type of Inspection: CMRO VA **** FHA CONV 2. Property Owner: Robert B_ FichPr { Mailing Address: Box 2357, Big Lake Rt. Day Phone 892-6215 ; Wasilla, Alaska 99687 3. Name of Buyer: F. Michael Gilliland liailing Address: 1627 E. Dimond .9952'97 Day Phone 349-1140 4. Name of Lending Institution: First National Bank of Anchorage Nailing Address: P.O. Box 720 99510 Picone 279-4481 ext. 234 5. Name of Realtor or Agent: None Mailing Address: Phone 6. Legal Description: Lots 6 & 15 Blk 5 John Wells S/D Location: East 86th Court 99502 Please contact buyer -he has key and will be available upon appointment 7. Type of Facility to be inspected: residence No. Bdrms. .3 8. Water Supply Type of Supply: Public Utility Individual ****** If Individual, number of dwellings presently served 1 If Individual, depth of well 186' ( Sub. Pump) 9. Sewage Disposal- Sy.:tcpi Type.ol System: Public Utility Individual (on-site) **** If Individual, date of installation unknown Aprox. 4yrs ago n Page 2 of two pages Ret for Approval of Individual �r & Water Facilities Legal Description ��# ` �r Alt Comments Approved ✓ ' .—� ,�� �`°1� Disapproved Date Approval`Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM 7AJ I certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. Date SIGNED EQ -034 (1/14)