No preview available
HomeMy WebLinkAboutTHUNDERBIRD FALLS LT 2Onsite File d T L The 1975 field may not be tested for a 4 bedroom Municipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page of ON -SITE WASTEWATER INSPECTION REPORT Permit Number: _0SP201348 PID Number: 051-411-05 Dwelling: OR Single Family (SF) ❑ with ADU [] Duplex (D) [:1 Two Single Family Project: El New X Upgrade Name Norman Campbell ABSORPTION FIELD Site Address 0 Deep Trench F0 Wide Trench F] Bed Ej Mound 26445 PARADIS LN, CHUGIAK AK El Other Phone Number of Bedrooms Soil Rating depth from original grade 907-441-8848 4 1.2 GPD/SF ITotal 12 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 10 Ft. 2 Ft. Thunderbird Falls 2 Fill added above original grade Gravel length Township Range Section 0.3 Ft, 3 x 25'= 75total Ft. Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES 5 Ft. Ft. To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 535 Fc 3 6 Ft. 1 Well 100+ 00'+ 1 TANK ljn� Septic El S.T.E.P. E] Holding 17 Other ----------------- =_ I Manufacturer Capacity Surface Water 100'+ 1001+ Greer 1250 Gal, Material Number of compartments Lot Line 5'+ 1 + NA Polvethelvne 2 Foundation 10'+ 10'+ LIFT STATION Manufacturer Capacity Remarks N/A Gal. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 dTank to D3034 Installer Martin Construction Company rainfield Drainfield D3034 CO/MT D3034 Inspector Crewdson Engineering, LLC BENCH MARK (Assumed elevation) 100 ft Inspection Inspection 1,t 11/02/2020 11/10/2020 Location and description 2" 3'11 11/11/2020 41' 11/12/2020 BOTTOM OF SIDING, SEE BM ON PLANVIEW 1 ON -SITE WATER AND WASTEWATER SECTION APPROVAL OF A4,1 \11 Conditional Approval: Date oe H Y Septic System Approved - Date3/ 31?_ am rewdson.- `11527� V-1 - I .5 f %ll F E S Note: this approval does not include well permit requirements. (Rev 05/02118) /+ 60 +� o //+ / IC TA SEE NOTES FOR DETAILS TRU-FLOW SPLITTER SYSTEM 4BR SFH z lIj BM B O 10'+ �H S1 2 ,: .W DRAINFIELD SEE NOTES FOR DETAILS 3 6 .\ TH1 D2 O / �\ +M2 C2 O + M4 C4 -oO\ C6 4 `J M6 MBA J LEGEND AR - application rate BOH - bottom of hole BR - bedroom C# - cleanout D# - drainfield DC - double cleanout ED - effective depth FC - foundation cleanout GPD - gallons per day IAW - in accordance with M# - monitor tube MBR - membrane bioreactor MH - 24" manhole riser MPI - minute per inch PL - property line ST - septic tank S# - septic tank riser SD - separation distance SF - square foot SFH - single family home TD - total depth TH# - testhole DRAINFIELD / /� GRADE ELEV SEE NOTES 70'+ FOR DETAILS BENCH MARK BOTTOM OF SIDING ELEV D1 D2 D3 EG 100.6' EG 101.8' EG 102.6' EG 103.4' ASSUMED ELEV 100' FG 100.9' FG 102.1' FG 102.9' FG 103.7' FG MH S1 DC C# M# M# C# Q� V O SEPTIC TANK ELEV DRAINFIELD ELEV TOT 94.7' DI D2 D3 RADIUS INLET INV 94.1' INV 91.8' INV 92.6' INV 93.4' OUTLET INV 93.9' BOR 89.8' BOR 90.6' BOR 91A TH1 BOH 83.8' TH1 BOH 83.8' TH1 BOH 83.8' PLAN GWT DRY GWT DRY GWT DRY PROFILE SCALE: 1"=30' NOT TO SCALE NOTES 3.1. TH1: SP,<1 MPI, DRY, 18'BOH, 1.2AR 1. All components and construction is IAW 3.2. (3) ZED x 5'W x 251, 127D AMC 15.65 4. Replacement Drainfield 2. Septic Tank 4.1. BioBarrier MBR, 50AR 2.1. Greer Poly 1250 4.2. ZED x 5'W x 51, 127D 2.2. Located >10' from building foundation 3. Drainfield: 4-Bedroom Wide Trench Crewds Civil Engineering .LC Box 671389 Chuglak AK 99567 • cellc.l @oudc Cell/Text:907-280-9493 • Fax:907-688-2295 Thunderbird Falls, Lot 2 Septic System RECORD DRAWING Prepared for: Norman Campbell Date: 1-10-2025 Permit: OSP201348 Page: 1 of 1 ALL INFORMATION SHOWN ON THIS DOCUMENT IS THE PROPERTY OF CRENOSON ENGINEERING, LLC AND SHALL NOT BE USED FOR ENGINEERING OR CONSTRUCTION PURPOSES WITHOUT WRITTEN PERMISSION FROM CREWDSON ENGINEERING, LLC •�.- ..► OF A(,g k�k !�,• 1 •.9TH '• J s A. Crewdson ` c • C11527 Ai PROFESSIONAW a .� ALLC #112279 tO Q0 0 Q0 � �,., \ 2g� 96 WELL C) 0 Q :�i F_ > (n ry LLJ Li F- < 0 ry NO + .0 LCI CHICKEN - tK- 01 + COOP + GREEN '� Gj� tK Q� + HOUSE _�p 00 .0- MH* Al • CD %* 0 CD 0 a 0 SEPTIC 00 0 VEN T :7 (typ) 00 �_10 AS -BUILT OF: THUNDERBIRD FALLS SUBD LOT 2 PLAT 70-385 SURVEY CERTIFICATE: 1,, John L. Schuller, Have conducted a physical survey of this property as shown on this drawing and that the improvements situated hereon are within the property lines and no enchroachments exist other than noted. Under no circumstance should any information on this drawing be used for construction of fences, structures, improvements, or for establishing boundary lines. EXCLUSION NOTES: It is the owners responsibility to detemiine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. WORK ORDER NUMBER: DATE: SCALE: E-MAIL, NOV 20, 2020 1"=40' 20____ 086 DRAWN BY, ICHECKED BY, GRID NUMBER: BOOK/PAGE: JLS NW1 764 200244 LOT 1 � 2 881 LOT 2 9 �a. SHED LOT 3 9 = FND 5/8" REBA.R ANCHORAGE RECORDING DISTRICT., ALASKA V U �R y L 00P 00000, 600� ammu-mmm ®Xxx: S .� AW A O....F N LAIVI) ,� JA r 9TH ?A * I 4 i .... W FA............... ....... A -JOHN L. SCHU11ER.- 0 of, 'Cl/ C)IS 'f 'o� -. LS-10408 _1-% OP� 'X0 AP 1831 Talkeetna Street pvU bw Anchorage, Alaska 99508 0 f E?sSioncl\ (907) 227-1455 office (907) 274-4992 fax MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://wv,fw.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP201348 Work Type: Septic Upgrade Tax Code Number: 05141105000 Site Legal Address: THUNDERBIRD FALLS LT 2 G:1764 Site Mailing Address: 26445 PARADIS LN, Chugiak Owner: CAMPBELL NORMAN L Design Engineer: CREWDSON ENGINEERING, LLC This permit is for the construction of: Effective Date Expiration Date It enr o U Departrient Lot Size in Sq Ft: Total Bedrooms: 9/21/2020 9/ 21/2021 61899 Q Disposal Field Q Septic Tank Holding Tank Privy Private Well Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: J Date: Issued By: GU Date:Z Zd 3 MUNICIPALITY CH E Development Services Department f` Phone: 907-343-7904 On -Site Water & Wastewater Section - Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-411-05 Property owner(s) Norman L Campbell Mailing address P.O. Box 671901, Chugiak; AK 99567 Site address 26445 Paradis Ln, Chugiak, AK Legal description (Sub'd., Block & Lot) Day phone 907-441-8848 Thunderbird Falls Lot 2 Legal description (Township, Range & Section) Lot Size 61899 Sq. Ft. Number of Bedrooms�� APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field M Initial ❑ Single Family (SF) Q (w/wo ADU) Septic Tank Ex -1 Upgrade FE Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: COy Ira Date of Payment: �� 31 I do�_o Receipt Number: of 5 b 1 1 `'1 Permit No. 03P2013y13 Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc tank Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201348, Deb Wockenfuss, 09/21/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201348, Deb Wockenfuss, 09/21/20 SIEVE ANALYSIS PERFORMED BY CREWDSON ENGINEERING. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201348, Deb Wockenfuss, 09/21/20 GREA'�T-NCHORAGE AREA BORCI Department of Environmental Quality r - 3330 C Street Anchorage, Alaska 99503 NAM LOCATION INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM MAILING ADDR RIPTION /6" 2 PH ON SEPTIC TANK: DISTANCE��y/ _ Q /� D NUMBER OF FROM WELL -1 y . MANUFACTURERS MATERIAL J4& COMPARTMENTS —�— INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH % LIQUID CAPACITY GALLONS. TILE DRAIN FIELD: r / f TOTAL LENGTH DISTANCE FROM WELL FOUNDATION C�'-3 NEAREST LOT LINEOF LINES !�Lf— NUMBER OF LINES— DISTANCE BETWEEN LINES TRENCH WIDTH IN. TOTAL EFFECTIVE ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE T� / DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE _MATERIAL BENEATH TILE -r IN. ABOVE TILE G, IN. WELL: TYPE ></�� CONSTRUCTION BUILDING NEAREST NEAREST FOUNDATION LOT LINE , SEWER LINE CESSPOOL , OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCES: A/ INSTALLED BV:-yf / ` 6/ SEWER LINE DEPTH: d PIPE MATERIAL: +'L� LOT SLOPE: :0 REMARKS: Form EQ -032 DEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK . SYSTEM_ DIAGRAM OF SYSTEM DL Form 24L 8/GG WATER WELL DRILLER LOG Drilling Co. 14-11 Drillin. Inc. Driller Gene Jordan DO NOT FILL IN Well No. Permit No. Certificate No. Area �AT+js.►••Octriil•1"«,Use of Well Domestic Will Owner , Range, `Section, if known, or distance main Location -(address of:.Township road' _ 2nd road to ri ht ptest Mirror Lake Wayside turnoff. Size of casinj_ Depth of liole_ Static water level--22—ft- open end .( X ); Screen ( ): to •00 Leer (below) land surface. Finish of well (check one) Perforated( )• .Describe screen or perforation Nonowith 0 + 10XL. Well pumping test at--!? gallons per (h84k) (minute) for 1 hours .of drawdowa from static level. Was'casing,collar sealed with cement grout No Depth in -feet from Gi•,e details of foL-mations penetrated, size of material, color* Around surface and hardness. 0 TO Topsoil 14 TO.65 Brown Gravels cmnll, anndy TO TO TO_�_ TO TO TO' TO' TO - TO _ Medium Gravels waterboarinr, GREA' 4NCHORAGE AREA BOR! sDEPARTMENT OF ENVIRONMENTAL QUALITY ^L.O� MIT No. 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 D SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT NAME OF APPLICANT /l /L / ( �? MAILING ADDRESS �_�� -PHON INSTALLATION LOCATION LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK v SEEPAGE PIT DRAjN fY OTHER J _ !// TYPE AND SIZE OF FACILITY TO BE SERVED f4 FINANCED THROUGH TOHE INSTALLED BY soa TEST REsu Lrs �"'� �� %rP/✓1 /(J �-� 4N E: THIS PERMIT S NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE/e �� scel' �TYPEAGE / MINIMUM DISTANCES. REQUIREMENTS �X FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT . DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL f SEPTIC TANK • SEEPAGE PIT . DRAIN FIt6 TO NEAREST LOT LINE. / f WELL TO SEPTIC TANK Ile • SEEPAGE PIT DRAIN FIELD -010 . ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK DRAIN FIELD SEEPAGE PIT SEPTIC TANK.- SEEPAGE PIT DRAIN FIELD TO RIVER. LAKE. STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL, 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. q GRAVEL BACKFIL CONFORM TO BOROUGH REG LATIONS REGARDING INSTALLATION. G.A.A.B. OR LICENSED DESIGNER IZE T E p�pGRAM OF SYSTE�p,�(,,/_ 4-JWGRAM /In I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28.68 AND THAT THE ABOVE DESCRIBE SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATE i PLICANJ'S S GNATU RE/� F N . -016 ? (_- � 9 Ole/ 5p'�: ._ 47 /I wj_-4- 1 IT -'4-�--I, ---j-- _ 47 - IA I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28.68 AND THAT THE ABOVE DESCRIBE SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATE i PLICANJ'S S GNATU RE/� F N . -016 ? (_- � 9 Ole/ 5p'�: ._ .0 Et E GEOTECHNICAL Et DEVELOPMENT CO. Box 90, Davis St., Eagle River, Alaska 99577 694-2774 or 688-2280 Russell Oyster 694-2774 Soils & Foundations SOIL LOG Earl Ellis 688-2280 Land Development Performed for: Name: -51C CC .VC L77XC4dTel. No. Mailing Address: /,60X 7:5-0 574- le leOUT'H, G°f/rJl//tiG, iql-- Legal Description: 2—or Z, Ti°frlA149.e5/LBs2p �/�c.c.s -Sdh'- Depth (feet) Soil Characteristics 0 1 2 3 4 5 N%L - S/G 7- 6 6 7 8 9 10 11 112 /-2V Ground Water Encountered: Yes No r-- If yes, what depth Proposed Installation: Seepage Pit Drain Field ✓` Comments: I \ Municipality of Anchorage -� Development Services Department Building Safety Division On -Site Water and Wastewater Program S . :. 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519650 www.ci.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. HAA# QL4 Q (qG Expiration Date: ! — % 1. GENERAL INFORMATION Complete legal description ULOCI? 151KD F.tu.S AZ _ Location (site address or,directions)�/n 15xe P-,4 r n I -T .1r� Current Property owner(i) &Y ,5,4aUc1Y Day phone Mailing address Lending agency Mailing address Real Estate Agent Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. Day phone Day phone 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm .tcff P.��$ F.ic: ,FFA,, r tj r� Phone �e!76/ 51-9 AddresseP6�gL6/F�tl p—ro —5,,,r& �?Dy Engineer's Printed Name e iyy.nre3 j ,�,e=,z .P JA 1,W2_ Date 5. DSD SIGNATURE Approved for 3 bedrooms. Disapproved. Conditional approval for �A k " 577 bedrooms, with the following stipulations: Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By: —�� /N • �� Original Certificate Date: (Rw. 01J02) Municipality of Anchorage • Development Services Department Building Safety Division ` On -Site Water & Wastewater Program 4-0- 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.enchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: .2�r- ,BZ40 f«Y .[, Parcel ID: eS/ y// m5 - A. WELL DATA Cwb Well type _ZkewArCC /o If A. B, or C provide PWSID # �/ Well Log (1 Date completed &&W.,0/6(p Sanitary seal(ON) _#f, Wires properly protectee N) Y ca Total depth -J--fft. Cased to�_ft. @,OW Casing height (above ground) n. F=L%LO,6 C(3 1J Date of test 13fiF Static water level 4w* $ ft. Q L3Tr% Weil production -bre"+ /e'l g.p.m. 66111 it rJ+N& AvklutBtd WATER SAMPLE RESULTS: Coliform ,_0_colonies/100 ml. Nitratem ?37mg./I. Arsenic: JM mg./I. Date of sample: ;V-x/01V B. SEPTIWHOLDING TANK DATA AT INSPECTION S/y/e y �S ft. g.p.m. Other bacteria 3 oolonies/100 ml. Collected by: 4 .YArLpy Loverrdafr Tank Type Aal� term dEAr& a& as Date installed Tank size' 104910 gal Number of Compartments �_ CleanoutspN) Foundation cleanout (YIN) 'vim Depression over tank (1(o _A& High water alarm (Y69 �Qe W SLP. w—wQ�l3 Date.of pumping Z: / SIOV Pumper �T & 1 ..3 tPu HPInAS - C. ABSORPTION FIELD DATA Date installed -ZeZX1j7,f'SoI1 rating (g.p.d.e or ftp 1,jf System type TeRrAgeW Length y.T ft. Width 3 ft. Gravel below pipe e5- ft. Total depth� ft. Eft. absorption area�ftp Monitoring tube'%"" Depression over field 4,b Date of adequacy test OE:&/o Resultq1TOIFail) P*js For -,.3 bedrooms Fluid depth in absorption field before test _= in. Water addedf�Mal. New depth in. Elapsed Time: go— min. Final fluid depth in. Absorption rate >_ -41f-e g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) ",Olclor- If yes, give date D. LIFT STATION Date installed 'Pump on' level at in. Da E. SEPARATION DISTANCES N60� 'Pump off" level at _ in. Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot /V-9, Absorption field on lot /6 - Public sewer main 71 zbw Manhole/Access (Y/N) High water alarm levet at Meets alarm 8 circuit requirements? On adjacent lots t AV On adjacent lots 7► /Vo , Public sewer manhole/cleanout t 04V Sewer /septic service line 711 .1 Holding tank -f /DD e SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 9 e Property line —,:fY ' Absorption field Water main V° lVe J. Water service line y'�lOr Surface water >` /do r Wells on adjacent lots f 110A I in. SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 6�2 Building foundation A 3 , Water main -►/BD Water Service line -1,X9 Surface water > A" � Driveway, parking/vehide storage Z;V r Curtain drain Nymi; &4XiwW 41Nells on adjacent lots 1/00" F. COMMENTS �L %CCAOJ BE SW*LtA-a POft w n0w._AJ&10 .r /tMCPS AP AIdA)�OXTATZMI GOnw� u1+r� G. ENGINEER'S CERTIFICATION n1p�1SCS d` MNNz. I certify that I have determined through field 'inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name G1 AP;7aP"t R. Wowop Date X419ADY HAA Fee ; `i -2, C/ Waiver Fee $ _ Date of Payment 0 Date of Payment Receipt Number 3 4 c� Receipt Number (Rev. 12/01) M.1 FFU-1.: P443 PROPERTIES FAX N(1. : 9376806644 Meq. 28 2034 04:QPM P2 ENCROACHMENT NON -OBJECTION AND AGREEMENT THIS AGREEMENT, made and entered into this day of . 20DA, by and between MATANUSKA ELECTRIC ASSOCIATION, INC., an Alaskan non-profit member owned electric cooperative of Palmer, Alaska, hereinafter tailed •First Party', and Trmothv A. Banach of P.O. Box 951, Dlginoham. AK 99576, Alaska, hereinafter called 'Second Party', WITNESSETH THAT: ding District, Alaska: A water fine is located within the secion fine easement and easements, and a well Is located within the section Iine easement. NOW, THEREFORE: for and in consideration of their mutual agreements and other good and valuable consideration, the receipt of which Is hereby acknowledged, First Party, for Itself, its successors and assigns, waives its objections to Second Partys encroachment on the said easements for the purpose mentioned, subject to the following conditions: 1. Second Party will hold First Party harmless from liability for arty Injury or damage to any person or property which may result from such encroachment 2. The said encroachment will be without prejudice to First Party's full enjoyment of any and all rights it may have in and to such easements. 3. Any facilities or property of First Party which are damaged or destroyed as a result of such encroachment vAl be repaired or replaced. The cost of repair or replacement will be paid entirely by Second Party. 4. Second Party will comply with all applicable safety codes and regulations. 5. Any expenses which First Parry may Maur In the relocation or modification of its faculties to accommodate the said encroachment will be paid entirely by Second Party. By Its execution of this Agreement, Second Party agrees, for Itself, its successors and assigns, that its encroachment upon the named easements as heretnabove mentioned wig be subject to the foregoing conditions. IN WITNESS WHEREOF, the parties have caused this Agreement to be executed by their duty authorized representatives and agents as of the day and year first above mentioned. MATANUSKA ELECTRIC Af.SOCIATION. INC. (First Party) BY: General Manager or his Repreaentattve TIMOT14Y A. BANACH (Second Party) ,5 ra-P� BY: TimothyA. Sana .h BY: — ? FTC. t FW.M PIR PERTl6 Fax HI : 9076936644 May. 2B 2004 e4:43PM P3 w Encroachment Non-Obiection and Agreement Page 2 ACKNOWLEDGMENT i�r^i20nct STATE OF AFA8KA SS. THIRD JUDICIAL DISTRICT : JYI' MS49ra ceun r����� The foregoing agreement was acknowtodged before me this ?`) day of f 1lL,Y 20 OU by Timothy A. Banach. Ala, && —� 'pFFIC1AL SEAL' Notary Public for the State of Alaska r r Zona r� LU°A Y.RALICKOVA OS � 9 I,. v Notary PuGic Stale of A zona My commission expires: ---,O ti�4� MaricopaCounty r.� My Commission Expires OSf t 9107 STATE OF ALASKA SS. THIRD JUDICIAL DISTRICT MEA ACKNOWLEDGMENT acknowledged before me this a day of tary Public for the State of Alaska commisslonmires: rr MO T?J)A � CALL ON YOUR COMPANY LW000-�NON-OBJECTION TO EASEMENT ENCROACHMENT DOCUMENT By this document Matanuska Telephone Association, Inc. (MTA) declares that it has no objection to the encroachment of a water line within the platted 10' Utility Easement upon Lot 2, Thunderbird Falls Subdivision, Anchorage Recording District, Third Judicial District, State of Alaska, situated in Section 36, T16N, R1 W, S.M. Please be advised that MTA through the issuance of this document does not forfeit any of its rights to the use of the area cited. In the exercise of these rights MTA will, if needed, upgrade, maintain, repair, and/or replace buried or aerial telecommunications facilities within the easement. Any repairs that may be required to the encroachment as a result of utility construction will be bome by the property owner of record. This document does not authorize the placement of any additional encroachments within the easement area. Property owners are required to obtain utility locates before doing any kind of work in the utility easements and will be liable for any damages caused by their construction work in the easements. This document is in no way, an aereement to vacate any portion of the utility easement and should not be intemreted as such. Issued for Matanuska Telephone Association, Inc. this 21 ' day of May, 2004, by, Real Estate & Properties Supervisor THIS IS TO CERTIFY, that on this 21st day of May 2004, before me the undersigned, a Notary Public in and for the State of Alaska, duly commissioned and sworn as such, personally appeared Bonnie Bailey known to me and to me known to be the individual named in and who executed the foregoing instrument and acknowledged to me that he signed and sealed the same as a voluntary act and deed for the uses and purposes therein mentioned. IN WITNESS WHEREOF, I have hereunto set my hand and official seal the day and year first above written. Notary Pub!.' in andlor My commission expires:O `/-dtaO -e- GRANTOR: Matanuska Telephone Association, Inc. P.O. Box 3550 Palmer, AK 99645 Matanuska Telephone Association, Inc. P.O. Box 3550 . Palmer, Alaska 99645.3550 1.800.746.9510 . 907.761.2510 . Fax 907.761.2646 Y!h7_28_04 SU 2:7J :Y May 28. 2004 Gr'- CAELE Norm CamrbclI 26945 Paradise Lane Chugizk, Alaska 99567 Dea: Air. Campbell. Subject to your agreement to indemnify the company as set forth below, GCI Cable lrc. of Alaska has no objection to the water line from the well encroaching into the 10' utility easement on the west property line of Lot 2, Thunderbird Falls Subdivision. i:nown as 26445 Paradise Lane, in city grid NW 1764. Ibis leder of non -objection in no way precludes GCI Cable from full use and enjoyrucrt of any rights it may have within any portion of the utility easement and or the right-of- way, including unlimited access for servicing its facilities. Also any additional and extraordinary costs incurred during any future required construction, repair C'r reconstruction of GCI's facilities to accommodate any or all of the encroacl'mcnts shall he paid by the property owner. By signing below, you agree to indemnify and hold GCI Cable harmless, now and forevur. t'c.r any damage, costs, expense (including reasonable attorney's ices), liabilities and 'injury to any person or property occurring as a result of the encroachment. Plcase indicate your acceptance by signing and returning this letter myself at the address below. Sincerely. A ce ante 6' 4k�� n OSP Project -tanager 1-i- e FCA-.... Date 5151 Fairbanks Street • Anchorage, Alaska 99503 • 907 / 858-5600 May 21 2004 1:57PM 7 : . 6/2112004 Norm Campbell Fax #: 688-6644 To whom h may EMOTnR E ineering ENSTAR Natural Gas tompi I, Northwest corner of Lot 2, Th de Feet wide (20 FT) uti;ity!ease nt. 907-502-0053 p.3 ENSTAR Natura l WCo mpay QIMalFQ1%Y 431 E Intamational Airport Road P. O. asr 19C239 AnChorayk, Alaska 99519-0253 (907) 3347743 FAX (907) 552-0]53 Re: Letter of Non -objection Grid: NW1764 no objection to a water line running from the b Falls Subdivision through an existing Twenty Acceptance and use of this tter of non -objection by yourself, your heirs, your assigns, or your successors, I constitute agreement to the following stipulations: ENSTAR will be paid 1- les$, now and forever for any damages or injury to any person or property a resllult of this encroachment. Any ENSTAR facility d aged, or destroyed, as a result of this encroachment will be repaired at no c to ENSTAR. Any costs Incurred by STAR for special construction necessitated by this encroachment wi8 be b r e by the property owner. All applicable salty regulations will be observed and maintained. This letter of non'lobjeo c n willlinno way preclude ENSTAR from full use and enjoyment of its r'his tin arty portion of Its right-of-way. Since M. cc: File ANCHORAGE WATER & WASTEWATER UTILITY "A New Standard of Excellence" Owned by fie Municipality ojAnchorage Norm Campbell Fax #688-6644 Engineering Division Anchorage 3000 Arctic Boulevard All -Am Anchorage, Alaska 99503-3898 1 fax 907.562.0824 I I I http://www.awwu.biz 2002 Mark Begich, Mayor May 24, 2004 Re: Thunderbird Falls, Lot 2 (Grid NW 1764) Encroachment into Easement Dear Property Owner: The Anchorage Water & Wastewater Utility received your request for a letter addressing AWWU's position regarding the existing well's service line that encroaches into utility easements located on the referenced lot. An as -built drawing with well location, service line location and easement locations was submitted with the request. AWWU water and sanitary sewer mains are not available to the referenced lot. AWWU is not using the utility easements and has no objection to the encroachment. If you have any questions, please call me at 343-8009 or the AWWU Planning Section at 564-2739. Sincerely, Q4 . 9axxj� Hallie Stewart Engineering Technician G:\Engineering\Planning\Planning\HMS\encroachments\encr Thunderbird Falls.dot Voted Best Tasting Water in America -1998 U.S. Conference of Mayors BASIS OF BEARING (PLAT 1971-60) S89'59'00'E 299.76' (300.00' Rec) U Io � II O� o o \I� I I \ I •' MCU .°II I i I UNC KVICH CASEMENT I. I I• I tW UTNTY CASEMENT / r U • I I o , N I I (v0. zo N I / STATE LANDCD '•I o I El - CCD I • / y I KN13 W FA v LOT 1 6.9 \ S59'12'50'E VJ U B, N � C? 4 Cl) Cq LOT 4 N ch 3 a '3 ao N p o / 0 0 0 0 N o 8.39' (S59 26 00 E 8,41'Rec) f m• uuun u:cuar 0�2 LOT 2 -C, ERRY Looe f ' 1ho • �'*'Q-" 49TH *1� ...:. .. .. ... / L. SCHULLER • I '" LS -104'0/8 P baw • LOT 3 ��O fessionoax w LEGEND: FND U• II SJ8"RB • Noma:CALL. POINT w I I DISTANCE ALONG THE SOUTHEAST PROPERTY LINE OTHING SET THIS SURVEY) ARB COMPITTBD. THEY DO NOT MATCH RECORD INFORMATION. THERE ARE ERRORS WITHIN THE ALL RECORD INFORMATION _ RECORD PLAT AND LOTS I AND.2 DO NOT MATHAMATICALY CLOSE. iS PER PLAT (1971-M) - •+ SMHTH SCHULLER COO LAM SNIIBVI& YING * MAPPING * PLANMG 233Il W—UMIROUG19I IID1UVIK9 AN` CEIGRAQaIE ALASKA MN TMRAM# (9M 337-6M ASBUIO T ®IF: ILIEGAIL DZ5C IBIIIF'11' ON T H[UNDIEII MIRR1m IFAI[ W SUMID)UMUGN IL®T 2 (TMT 1971-M) 30TH APRIL 2004 1 1"=50' 1 t 04-0941 DRAWN BY: I CHECKED BY: I GRID NUMBER: CKS JLS N W1764 SURVEY CERTIFICATION. SMITH LAND SURVEYING hu conducted a physical survey of this u shown oa thL drawing and that the impsovemrats dW=therom ane within the Property lion and no encroachments exist other than noted. EXCLUSION NOTES.It is the owners raponslaity to debmnl e the ubtmce of nay eauman oavenaats, or raodcdoos which do not appear an dw reoccded subdivision plat. Note: Under no conshwtlm :north® ci.net ��lAw"� mon be�� or for eslabUddng property linos. BDOK AGE: 04-001-17