HomeMy WebLinkAboutGREENLAND BLK 2 LT 3Greenland
Block
Lot 3
#015-172-16
Municipality of Anchorage
On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3
ON -SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP241200 PID Number: 015-172-16
Dwelling: X Single Family (SF) ❑ with ADU El Duplex (D) El Two Single Family Project: El New X Upgrade
Name
MICAH & HOLLY BOYER
ABSORPTION FIELD
Fj Deep Trench RN Wide Trench M Bed M Mound
Site Address
4900 E 11 3TH AVE., ANCHORAGE, AK
0 Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
907-240-16r,i53
1 4
0.8 GPD/SF
1 SEE DWG. Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
SEE DWG. Ft.
Gravel depth beneath pipe
**2.06 2.01 FL
Subdivision Block Lot
GREENLAND 2 3
Fill added above original grade
SEE DWG. Ft.
Gravel length
**56.5 55 Ft.
Township Range Section
Gravel width
5 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
796 Ft2
2
6+ Ft.
Well
100,+
100'+
100'+
-
25+
TANK [I Septic [9 S.T.E.P, [__1 Holding [I Other
Manufacturer
GREET TANK
Capacity
1500 Gal,
Surface Water
1001+
1001+
1001+
-
Material
Number of compartments
Lot Line
51+
*11+
51+
-
NA
PLASTIC
2
Foundation
10'+
10'+
10'+
LIFT STATION
Capacity
IManufacturer
Remarks *LOT LINE WAIVER GRANTED (OSV241030)
GREER TANK/ ANCH. TANK
—500 (2ND COMP.) Gal.
NORTH TRENCH / SOUTH TRENCH
Alarm location
INDOOR/6GE
Electrical installed by
7
Installer
PIPE MATERIAL House to tank D3034 Tankto drainfield D 1785
JR'S EXCAVATION
Drainfield D3034 CO/MT D3034
Inspector GEG
BENCHMARK (Assumed elevation) 100.00 ft
Inspdatesn ectio1 st 8/7/2024 11/25/2024
Location and description
: 2nd
31d 11/25/2024 41h 11/2612024
BACK DOOR THRESHOLD
ON -SITE WATER AND WASTEWATER SECTION APPROVAL
Engineers Stamp
Conditional Approval: Date
4=7
s0
0
.
o
9 T
......... ....... ..........
Ai
Septic System
Approved Date
arn ss
CE-7 3
7#'
Note: this approval does not include well permit requirements.
(Y10rof e' 57101,
#AECC8U �61
I
(Rev 05102/18)
PERMIT
OSP241200 RECORD DRAWING 015-172-16 NUMBER: PARCEL ID NUMBER: I
/
i�
1
I
I
I
1
1
1
1
1
/
I . \ I
1
R.O.W. EASEMENT—/` b
EXISTING
4-BEDROOM /
HOUSE /
A
i
OLD DRAINFIELD. PER CONTRACTOR,
DECOMMISSIONED IN PLACE. NEW
OWNER TO REMOVE CO'S AND MTS IN
THE SPRING/SUMMER OF 2025--\
NEIGHBORING
DRAINFIELD
N
1" = 40' LGENERAL LOCATION OF
MICHAEL ANDERSON,
P.E. 2005 TEST HOLE #1
GENERAL LOCATION OF VEGETATED DRAINAGE WAY./)?
NO VISIBLE WATER ON 7/11/2024 & 10/8/2024
EAST 113TH AVENUE
A B
FCO 14.5 37.9
C01 35.6 48.5
MH1 37.6 49.4
MH2 41.6 51.4
DBL1 43.6 52.6
DBL2 44.6 53.1
MT1 104.7 111.6
MT2 130.3 113.1 f
MT3 119.0 120.0 /
MT4 144.2 125.E /
NOTE: PIPE LOCATIONS ARE
SHOWN PER GEG SHOTS
TAKEN WITH LEICA DISTO
S910LASER DISTANCE
METER, SWING -TIES TO
HOUSE CORNERS WERE
GENERATED IN AUTOCAD.
i
NEW 1500-GALLON GREER
PLASTIC STEP TANK WITH
ORENCO COMPONENTS
PER THE CONTRACTOR, THE LINE
AFTER DOUBLE CLEANOUTS ON
OUTLET OF TANK WAS CAPPED AND IS
NOT CONNECTED TO OLD DRAINFIELD
1-1/2" SCH 40 PVC PIPE
GENERAL LOCATION OF
MICHAELANDERSON,
P.E. 2005 TEST HOLE #2
a
' 1' LOT LINE WAIVER
—Z GRANTED (WR241030)
Mra 1
I NEW ORAINFIELDS.
EAST 114TH AVENUE (UNDEVELOPED)
GARNESS ENGINEERING GROUP, L
-• ... ENGINEERING � SALES,, CONSULTING
3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE, ALASKA • PHONE (907) 337-6179' VVESSITE www.aamassonaineet(no.com
PREPARED FOR:
MICAH AND HOLLY BOYER
PHONE NUMBER:
907-240-1653
PAGE NUMBER:
2 OF 3
PROJECT/LEGAL DESCRIPTION:
DRAWN BY:
GREENLAND; BLOCK 2, LOT 3
J.L.M.
TYPE OF WORK:
DATE:
RECORD DRAWING OF SEPTIC SYSTEM UPGRADE
12/6/2024
>f
U CE-79 3 Z'n
�� F,p'••.,, t Z�b Z t•.••''� 40
SfLICENSE t,� ESS, .W
#AECC884 raaal�
PERMIT NUMBER: PARCEL ID NUMBER:
OSP241 00REC"ORD015-172-16 FINAL GRADE
TOP OF MANHOLE 98.47-98.52 TOP OF MANHOLE
= 98.84 = 98.80
W
DBL1 DBL2
L�1
MH1 MH2 -
TOP OF TANK Li
INLET = 94.89 tip
7
0 ul Q
TOP OF TANK NOTE: PER CONTRACTOR TANK U. - 2 qq m �`
.. CV
OUTLET = 9�4.89 HAS 2" OF INSULATION OVER IT w �' z cy � �- m
TOP ET TANK (NOTE SHOWN FOR CLARITY) w Q z 0
INLET = 94.89
w p� H�
d d
,,,,---PER CONTRACTOR, LINE :
• AFTER DOUBLE
CLEANOUTS WAS CAPPED
INVERT OF PIPE
INLET = 94.22
PUMP FILTER, PUMP, y
FLOAT CONTROLS, ETC.
SUPPLIED BY
1",
ANCHORAGE TANK-411
x
NEW 1500-GALLON
GREER PLASTIC
E
STEP TANK
3
i
AVOW
Lj
a.
W
SOUTH G MT#1 ! G MT#2 NORTH i
NOTE: CONTRACTOR PULLED
. TRENCH ��� r
..
IL
MOTE. BENCHMARK FOR PROJECT IS MT3 BOTH GWM TUBES DURING TRENCH MT1
MT4FINAL GRADE TRENCH CONSTRUCTION FINAL GRADEco
MT2
BACK PATIO [BOOR THRESHOLD = 100.00 ��
= 1 C}ti.ilf�-1 Qfl.55 = 1 Qfl.33-1 flfl.54 �� � .J
GRADE @ GWM-MT 1 = 99.00 W
GRADE @ GWM-MT#2 = 98.11 .h CL UL
e
uju
wo
OF w
M
2°' OF INSULATION, 2" OF INSULATION,
NOTE: PRESSURE DISTRIBUTION LINES ARE PER CONTRACTOR PER CONTRACTOR
1.25" SCH. 40 PVC WITH 3116" HOLES (FACED FILTER FABRIC
DOWN) SPACED 3-FEET ON CENTER. 18-HOLES FILfiER FABRIC c,
PER LATERAL - 39-HOLES IN ENTIRE SYSTEM
© L
• w
V 0
w • ,; ? asp•—.
• w m
• • INVERT OF DISTRIBUTION • i INVERT OF DISTRIBUTION' -
• • LINE - 96.51 w •
LINE - 96.56
i • • i e2. ,^: tip �, Li.
ww
5-FEET WIDE , :M $ ' _ w , �ti f ' r _ :- `• .p./p (/�}
BOTTOM OF DRAINROCK 94.50 61_ ' ' .` ` ``
-'$ �` Y .� ' `'� `� TOP OF MOA FILTER SAND / w
BOTTOM OF DRAINROCK 94.50
CF tilt,
:+� ' ry 1-p r sa : ;,•' 4.5* FEET OF
IMPORTED ♦4► , i i ' ++
4_ Air +
s4 .T 8 . "1 Jb«•'. m°'..•' �.'• MOA SAND*
Air
AIF
` r,• Alt-7 Z- ♦ 1
. �• " � ii.iiisiiiiiii die eiiiaiiiiiieeaiAll
feaaa�
_ ',,. •ter y y-._ _ .. .... a:•'. t•• .
r '• iiiiiiii i
GROUND WATER MONITORING GV1(I TUBES INSTALLED N 10181SAND) asset seas'.. es' i■i
O 2024 PRIOR TO PLACING MOA FILTER ". _• '
7-DAY GROUNDWATER MONITORING
I G -GWNI TH1 - 90.32 ON 10/15/2©241 G-TH#2 = 90.23 ON 10/1512024 i//)//►.i`j-niy/+
5-FEET WIDE Now APPROXIMATE LIMITS OF EXCAVATION OF TRENCH = `'` +�a cos �,,�,Ar
PROFILE 1 ! 3t3.00# GROUNDWATER ENCOUNTERED. ► ' a�a�.ee.evaa**s ►
VIEW OF DRAINFIELD UPGRADE ♦ p.
♦� EIS tc�' ,+
LICENSE ���'''"�'"'►
#AECC884•
LAJ
LILJ
40
IAJ
z �.
a
ui'
,
ui
a
0
ui
LU
tl
$: 3
40 2,
3`
F
4At
.:
e
:.
a
alt
;
d>
s
�F
Alt
s
xg
aka'
�
fir: 1f
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP241200
Work Type: Septic Upgrade
Tax Code Number: 01517216000
Site Legal Address: GREENLAND BLK 2 LT 3 G:2636
Site Mailing Address: 4900 E 113TH AVE, Anchorage
Owner: BOYER MICAH JOHN & HOLLY RENEE
Design Engineer: GARNESS ENGINEERING GROUP LTD
This permit is for the construction of:
Effective Date:
Expiration Date:
S':
J
fi
L)cpartmtrIIt
Lot Size in Sq Ft:
Total Bedrooms:
7/24/2024
7/24/2025
27000
Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
11 bV*1
1 �25i yo` 4 4,,ctcc /4710
J
Reee*ved-By:
Issued By:
Date:
Date: 71z_Y1 �(
4
Mun*dpaflty of Anchorage
Ihp;n ttnt nt ..
P.O. Box 196650 0 4700 Elmore Road
Anchorage, Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997
http://www.muni.org/Onsite
Development I Division
On -Site Water and Wastewater Program
* * * * VARIANCE/WAIVER REVIEW * * * *
Waiver#: OSV241030 COSA#: Permit#:OSP241200
PID#: 015-172-16
Legal Description: GREENLAND BILK 2 LT 3
Engineer: Garness Engineering Group
Your request for a waiver of the required 10 feet horizontal separation from the absorption field to
the property line has been approved. The approved separation distance is 1 foot to the east and
west property lines.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-
site wastewater disposal system will require all separation distances be met or another approval
from this department.
Waiver is Granted: X Waiver is not Granted:
Date: Approved Z Approved by: --
—
Name of Reviewer
**** VARIAN C E/WAIVER REVIEW ****
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 015-172-16
Property owner(s) MICAH & HOLLY BOYER
Mailing address 4900 E 113TH AVE., ANCHORAGE, AK
Site address 4900 E 113TH AVE., ANCHORAGE, AK
Day phone 907-240-1653
Legal description (Sub'd., Block & Lot) GREENLAND; BLOCK 2, LOT 3
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(N all that apply)
Absorption Field
❑X
Initial ❑
Single Family (SF) ❑X
(w/wo ADU)
Septic Tank
❑
Upgrade ❑X
Duplex (D) ❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
DRAINFIELD TO EAST AND WEST LOT LINES
Distance: 1
certify that the above information is correct. 1 further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: S� Waiver Fees: Z
Date of Payment: l Z f"%y° Date of Payment:
Receipt Number: Receipt Number:
Permit No. t�? 'Z L/2_0 Waiver No. {' Z Y 1 0 .'
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc
d -N A
UARNESS ENGINEERING GROUP, Ltd
ENGINEERING SALES CONSULTING
October 16, 2024
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Attention Deb Wockenfuss
Ref: Revisions to Design of Septic System Upgrade for Greenland; Block 2, Lot 3
Ms. Wockenfuss:
A permit was issued for this septic system upgrade on 7/24/2024. A new 1500 -gallon Greer plastic
septic tank was installed on 8/7/2024. The tank was larger than required and 24" manhole risers
were installed on both compartments of the tank. On 10/8/2024 GEG was called out for a bottom
of trench inspection. Upon arrival, a significant portion of the 88 -foot -long trench had ponded or
seeping water in it near the bottom of the excavation. I disused the situation with GEG consultant
Jody Maus and asked him to contact you. After discussion, it was agreed that 7 -day groundwater
monitoring would be performed and the design revised. Two groundwater monitoring tubes were
placed in the excavated trench and then approximately 60 -feet of the east end of the trench was
filled with 4.5 feet of MOA filter sand. The west 28 -feet of the trench was backfilled with native
soil.
Attached is the revised design. We are proposing the septic tank be converted to a STEP tank
and that dual pressurized 5 -wide trenches (with 2 -foot effective) be installed. We request this
change -order be approved expeditiously so the contractor can proceed with the installation. We
are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179.
Jeffry 136rnes, P.E., M.S.
Presliit 1--i
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
•
July 11, 2024
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Proposed Septic System Upgrade for Greenland; Block 2, Lot 3
To whom it may concern:
The existing house is served by a private well and septic. The septic system was installed in 2005
for a 4 -bedroom house and consists of a 1,250 -gallon steel septic tank and a 5 -wide trench type
drainfield. The drainfield was 97% full on 7/3/2024 and did not pass an adequacy test. We are
proposing that the alternate (reserve) 5 -wide drainfield be installed. See the attached design
drawings, and specifications.
1. SOILS: See the attached logs which show the soil classifications, groundwater monitoring,
and the percolation test results for Michael Anderson, P.E. test holes.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: Attached is the MOA Watershed Wetland map for your review. There
is a vegetated drainageway south of the proposed drainfield. No water was found in this
drainageway on 7/11/2024. In short, there does not appear to be any surface waters within 100'+
of the septic system.
4. TOPOGRAPHY: The design drawing shows the general topographical information. There are
no slopes greater than 25% within 50 -feet of the proposed drainfield. In short, the proposed
drainfields meet the slope requirement set forth in the MOA Wastewater Ordinance.
5. LOT LINE WAIVER: The existing drainfield was issued a 1 -foot lot line waiver to the west lot
line (see waiver WR#050068). We request the waiver be amended for the alternate drainfield site
and to include both the east and west lot lines.
We are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179. Thank you for your
assistance. A
Jeffreyl (I3arnes`.E., M.S.
Presicl
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241200, Deb Wockenfuss, 07/24/24
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241200, Deb Wockenfuss, 07/24/24
DESIGN CRITERIA:
NUMBER OF BEDROOMS: 4
GALLONS PER DAY (GPD): 600
PERCOLATION RATES: 13.0 & 14.2 MINUTES/INCH
PROPOSED APP. RATE: 0.8 GPD SQ.FT,
\
/ ,/'-- c� •'; , .. •:
/
/
/
MINIMUM DRAINFIELD SQ.FT.: 750
1
DRAINFIELD DESIGN:
MAX. DEPTH: SEE PROFILE DRAWING, PAGE 3 OF 3
WIDTH: 5 -FEET
I
i'�•. r
LENGTH: 110 -FEET (2 @ 55' LONG EACH)
EFFECTIVE: 2 -FEET
MOA FILTER SAND: 4.5'+/- (IN EXCAVATED TRENCH ONLY)
REDUCTION FACTOR: 0.70
ACTUAL SQ.FT,: 786
'' " O!`'r ."
EAST 113TH AVENUE �\
GEG, Ltd. HAS AN 8 PAGE
SPECIFICATION LETTER THAT
PERTAINS TO THIS DESIGN. BY
PROCEEDING FORWARD WITH THIS
INSTALLATION, THE ENGINEER, WELL
DRILLER, CONTRACTOR AND
PROPERTY OWNER AGREE THAT THEY
HAVE READ THESE SPECIFICATIONS
AND AGREE TO ACCEPT THE TERMS
AND CONDITIONS OUTLINED.
� m /
\ \\ EXISTING
\� 4 -BEDROOM o
HOUSE / c " N
' \ FCA��/ .- ' �SCALE:
1" = 40'
NEW 1500 -GALLON SEPTIC TANK
INSTALLED ON Bl7/2024. TO BE
CONVERTED TO STEP TANK USING
DRAINFIELD. µx RISERS
TANK STEP TANK PACKAGE.
EXISTING S HAVE ALREADY BEEN INSTALLED
APPEARS BE
ENCROACHING ON rnx ON BOTH COMPARTMENTS
GROUNDWATER. TO BE NOTE: CONTRACTOR SHALL HAVE
DECOMMISSIONED IN PLACE THE EAST, WEST, & SOUTH LOT
LINES FLAGGED/STAKED BY A
REGISTERED LAND SURVEYOR
PRIOR TO ANY CONSTRUCTION.
i h
NEIGHBORING �\ ;� w ; GENERAL LOCATION OF
DRAINFIELD L: - �- y MICHAEL ANDERSON,
P.E. 2005 TEST HOLE #2
88' LONG TRENCH EXCAVATED TO -9' DEEP.
` _r
GROUNDWATER FOUND. SEE DETAIL ; �•...r,,! AREA FOR TRENCHES
IS GENERALLY FLAT
DRAWING FOR DESIGN REVISION _
t
f V LOT LINE WAIVER GRANTED (WR050068). i G
REQUEST NEW DRAINFIELD BE INCLUDED— ------ GWM 1' LOT LINE WAIVER GRANTED
(WR050068). REQUEST NEW
" - ---`� DRAINFIELD BE INCLUDED
NOTE: NO SLOPES GREATER
THAN 25% WITHIN 50+ FEET OF
THE DRAINFIELD UPGRADE PROPOSED DRAINFIELD
GENERAL LOCATION OF UPGRADE. SEE DESIGN
-�--
MICHAEL ANDERSON, CRITERIA AND DETAIL
---..__
P.E. 2005 TEST HOLE #1 DRAWING, PAGE 3 OF 3
GENERAL LOCATION OF VEGETATED DRAINAGEWAY. EAST 114TH AVENUE (UNDEVELOPED)
NO VISIBLE WATER ON 7/11/2024 & 10/8/2024 --w—
k
OF Al
:x
ENGINEERING SALES CONSULTING y
3701 E, TUDOR ROAD, SUITE 101 ' ANCHORAGE, ALASKA' PHONE (907) 3376179' WEBSITE: VN.w.gamessengineadng.com Z •••S•!9 ••• • t••�••••••r•••••••••••••s!
PREPARED FOR:
MICAH AND HOLLY BOYER_
PROJECT/LEGAL DESCRIPTION:
GREENLAND; BLOCK 2, LOT 3
TYPE OF WORK:
DESIGN OF DRAINFIELD UPGRADE
PHONE NUMBER: PAGE NUMBER.
907-240-1653 2 OF 3
DRAWN BY:
J.L.M.
DATE: REVISEI
10/16/2024
'+; V CE -7953
�`�;;Fo•pp..........1•?�•�P�,
#AECC884
LU
88' EXCAVATED TRENCH -GROUNDWATER ENCOUNTERED Om
-28' OF TRENCH BACKFILLED WITH
NATIVE SOIL -COMPACTED IN -60- FEET OF MOA FILTER SAND ADDED TO EXCAVATED TRENCH ON 10184/2024 J
LIFTS PER THE CONTRACTOR .I
1.5"SCH. 40 PVC FEED LINE - SLOPE TO DRAIN (NO BELLIES) AFTER EACH PUMP CYCLE O
^�1 = M
- O
O
O
m
w cnN
i
�r
M7+ Q
LL Ln
m
IL Z0) Wcr)O s� w�
1.25" SCH. 40 PVC PRESSURE DISTRIBUTION LINES WITH a a o
NOTE: CONTRACTOR TO REMOVE GWM-MT#2 » - 3/16" HOLES (FACED DOWN) SPACED 3 -FEET ON CENTER.
GROUNDWATER MONITORING TUBES 18 HOLES PER LATERAL -36 HOLES IN ENTIRE SYSTEM
PRIOR TO PLACING DRAINROCK
MTO
i
f
OMT �
52 FOOT LONG LATERALS ENDS CAPPED
(TYPICAL)
55 FOOT LONG TRENCHES
IE
PLAN VIEW OF DRAINFIELD UPGRADE
ra
z€
tit W
0
NOTE: BENCHMARK FOR PROJECT ISZ;
01,
BACK PATIO DOOR THRESHOLD = 100.00 GWM-MT#1
2+ FEET OF GWM-MT#2 2+ FEET OF
COVER MT COVER MT t%3�
w -
J
x
GRADE @ GWM-MT#1 = 999.00:t,�, LU
az:GRADE @ GWM-MT#2 = 98.11 V) Z
w
W? W
Zs co W
2" OF INSULATION 2" OF INSULATION d
Z. O
FILTER FABRIC FILTER FABRIC �� of
o N CL
Y LL
w O C9
INVERT OF DISTRIBUTION INVERT OF DISTRIBUTION p Z
LINE = 96.50 LINE = 96.50 a0
It w J
•• v
-.
wLu 0
W�i
5 -FEET WIDE - ow LLW
ui
TOP OF MOA FILTER SAND i `•.. n
BOTTOM OF DRAINROCK = 94.50 8+ i.` �' - ''-rJ; :` '•`". `+-' ` TOP OF MOA FILTER SAND /
- BOTTOM OF DRAINROCK = 94.50Ok
4.5t FEET OF ®O!^C� OF ° i,t
:�.• .=- MOA FILTER .®��\............ ,�•���
SAND ADDED/ 4 .•'` ••. ,�'
TO BE ADDED �•'� �',�
AV
t �....:.... .......1 ..........::.....0
GROUND WATER MONITORING GWM TUBES INSTALLED ON 101812024 PRIOR TO PLACING MOA FILTER SAND
7 -DAY GROUNDWATER MONITORING - GWM-TH#1 = 90.32 ON 10/15/2024 / GWM-TH#2 = 90.23 ON 10/15/2024 - p' .'..t:: r: ;' ? �- : ••effrey ar ess a Lv..
♦ �J,l. CE -7953 .�Ar
a
APPROXIMATE LIMITS OF EXCAVATION OF TRENCH = •�♦ (•• i o t -i ! �+ 1.�d/•� ��� 4 5 -FEET WIDE 90.00* - GROUNDWATER ENCOUNTERED. CALLED MOA + (���`'•+....... ..n••� +4
PROFILE VIEW OF DRAINFIELD UPGRADE ONSITE DEPARTMENT ONTO/8/2024AND DISCUSSED °+i pROFESS��Pi��
DESIGN REVISIONS AND INSTALLATION OF LICENSE M,IATA A
GROUNDWATER MONITORING TUBES. #AECC884
iL.i
>- c)
s
Q, Z
�J
s�
g
G
g a�
AR
x,
a s:
r
r b
3.
;
:
i
Municipality ot'Anchorage Page I of 3
Development Services Department
On-S~te Water and Wastewater Program
4700 South Bragaw Street
P.O. Box 196650 Anchorage, AK 99519~650
www.ci, anchorage, ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number. SW050071 PID Number. _ 015-172-16
Name
Merit Homes WastewaterSystem: New
P.O. Box 111982 Anchorage, AK 99511 ABSORPTION FIELD
334.9233 Four (4) 5' Wide Trench
LEGAL DESC RIPTIO N s~ ~ T,,~ o.~ ~,,,~ ~,.~
.8 ~o~e' 6 r,.
2 3 Greenland 3
1-3 E,. 88 F,.
Well: New c,,.,~
I
5
Private 223 E,. 223 E, 758 ~eASTM 3034 PVC
Alpine Drilling 7102/05 152 ~t Red Dog 5/11/2005
40 c~ F,. >2E, TANK
SEPARATION DISTANCES Ig Septic I-1 Holding I-1 S.T.E.P. [] Other:
Tank Field Station Tank Se~rU~ Anchorage Tank 1,250
w~ >100' >100' NIA N/A >25' Steel Two (2)
s~w.~,, >100' >100' N/A N/A ~/ LIFT STATION - NONE ON LOT
¥
t,,t~. >5' 1' N/A N/A
c~..~ o,.~ None Noted P~.,~
BENCH MARK
Carage Slab
Inspections performed by: AH Dates:
,,, -~.-.~,--.*./ .... ~.........~f.~,.._~
511110 5 e...Z~...~.~
Department of Health and Human Services approval ~, ~.\ .o ¢, ~,~,, ~.~'-'
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Ancl'~_r-a.~ AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal ~-y~er~ or Well Inspection Report
Permit Number. SW050071
Page 2 of 3
PID No. 015-172-16
EAST 113TH AVENUE
S 8~'~'20'[ 100.00'
48.7
52.9
112.1
111.9
95.5
96,7
GREENLAND SUBDIVISION
LOT 5, BLOCK 2
27,000 S.F.
·
,~.~..~.. ~...~ PLAN AS-BUILT
· ,.......- ~C-"~ ¢ _~ ~-;
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number. SW050071
Page 3 of 3
PID No. 015-172-16
1,P50 G~tton %
Septic Tank
5.65
9 13rolnFletd Rock ~ ~5.5
88' (Trench Length)
~ 80.0
PROFILE AS-BUILT
Scale: 1' - 10'
Sap 01 05 11:28a
ALPINE DRILLING & ENTERPRISES
Permit Number: #SW050071 Date oflssue: ,4-07-05
Date Started: 7-2-05 Date Completed: 7-3-05
Legal Descriptiou:
Property Owner Name & Address:
Borehole Data:
SoN T)~, 'l'Mekness & Water Steam
stick-up
organics & silt
gravelly silt
silt
silty gravel wet
silt
gravelly silt
silty sandy grave/ H20 I gpm
gravelly silt
silty gravel wet
water sand & gravel
Parcel Identification Number: 015-172-16
Is well located at approved permit location? [] Yes [] No
Green/and Sub BIk 2. ~.ot 3
Merit Homes
4901 E ~ 14'~ Ave,
Anchored/e, Alaska 99516
Depth (ft) Method of Drilling [] air rotaxy [] cable tool
From To
Casing type: .steel
0 2 Wall T~ckncss: .250 inches
2 5 Diamctcr: _6 inches Depth: 223 feet
5 21 LinerType:
21 62 Diameter: inches Depth: fcct
Casing stickup above ground: 2 feet
62 63
63 77 static ~vater level (~rom Found level): f52 feet
Pumping level: 223 feet after
77 103 _2 hours pumping 40 gpm
103 105 Recovery Rate: 40 gpm
105 113 Method of Testing: ~/rlift
113 198 Well Intake Opening Type:
198 219 [] Open End r-I Open IIole
219 223 [] Screened Start ~ feet Stopped feet
[] Perforations Start feet Stopped feet
Grout Type: Oentonite granules Volume: 1 Bg
Depth: Start_0 feet Stopped? feet
Pump: Intake Depth feet
Pump s/ze hp Brand Name
~,Vell Disinfected Upon Completion? [] Yes [--I No
Method of Disinfection: chlorine tablets
Comments: well was perforated at 104 Ia ! 0~ when
depth of 185 was reached The water diminished in
production so was not usable. The caving was continued
deeper $o the perforation$ are at a finished depth of 144-
145
Well Driller:. Alpine Drilling & Enterprises
PO Box 1'10496
Ancorage AK 99511
Attention: The '~ell driller shall provide a well log to thc property owner within 30 days of completion and the property
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Date Issued: Apr 07, 2005
Expiration Date: Apr 07, 2006
Permit Number: SW050071 Parcel ID: 015-172-16
Legal Description: ~GREENI.~ND SUBDIVISION BLOCK 2 LOT.3 /
Design Engineer: 0014 Anderson Engineering Site Address: 4901 EAST 114TH AVENUE
Owner Name: MERIT HOMES Lot Size: 27000 SQ. FT.
Owner Address: 4901 E 114TH AVENUE Total Bedrooms: 4 Permit Bedrooms: 4
ANCHORAGE, AK 99516-
This permit is for the construction of:
[] DisposalField [] SepticTank [] Holdingmank [] Privy
[] Private Well
[] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Issued By~
Date:
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWEPJVVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D.
Permit Number SW
Property owner(s) Merit Homes
Mailing address (1) P.O. Box 111982 Anchorage, AK 99511
~..~e..q address (2) 4901 East t14", Avenue Zip Code
Legal description (Lot, Block & Sub'd.) Lot 3, Block 2, Greenland Subdivision
Legal description (Section, Township & Range)
Lot Size 27,000 SF Acre qs~.Ft. Number of Bedrooms Four (4)
DayphoneT/0A999
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
[] Well Only []
[] Water Storage []
[] Jac, ,~i []
[] Water Softening Unit []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
1' '~ I?$"' /~aiver Fees:
Date of Payment
Receipt Number:.
ANDERSON EN
';.2..,:- ........... 522:7.773 ................ 522~779 {FAX}., ....................
MEMO
DATE: 511112005
TO: Joe Goodall
MoA/On-Site Water and Wastewater
FROM:
Mike Anderson
SUBJECT:
Lot 3, Block 2, Greenland Subdivision
Septic System Permit No. SW050071
Lot 4, Block 2, Greenland Subdivision
Septic System Permit No. SW050072
The topography of the subject lots makes it difficult to have gravity flow from the houses
to the septic system areas. We have themfora redesigned the absorption trenches to
have a 3' effective depth rather than the originally permitted 4'. The bottom of the
trenches will be a minimum 'of 4' above groundwater and 6' above bedrock as
measured today and In the next week. The length of each trench will now be 87' and
encroach into the lot line setback of 10'. Lot llne waivers will be submitted In the next
week to allow the absorption trenches to encroach Into the setback area.
Please review the aforementioned Information in conjunction with the previously
approved deslgn and advise If you have furl, her questions.
I/I 'd 8SIO'ON 6LLgZ~§L06 ~dOO:Z gOOZ 'll'XelN
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 522-6779 (FAX)
Apd17,2005
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 3, Block 2, Greenland Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:.
The owner of Lot 3, Block 2, Greenland Subdivision intends to construct a new four-
bedroom home on the property. We are therefore requesting a permit be issued for the
construction of a new well and septic system to serve the home. No conflicts exist
between the proposed well and septic system and those on adjacent properties. The
Site Plan and backup documentation identify the location and configuration of the
proposed well and septic system. Existing drainage arrows and the current drainage
pattern are also identified on the Site Plan. The drainage pattern will be maintained
after development of the new system is complete.
Test holes placed near the location of the new absorption trench and alternate site
revealed silty sand and gravel to depths of 16' to 17'. The accepting soils were tested
and found to have a percolation rate of between 6 and 15 minutes per inch. No
groundwater was found during excavation and none was noted during the monitoring
period. Our design includes the placement of a new 1,250-gallon septic tank along with
a new 75' long by 5' wide absorption trench with a 4' effective depth to collect and treat
the sewage generated in the house. The bottom of the trench will be 7' below the
ground surface. The distribution pipe will be 3' below the surface. A minimum of 3' of
cover will be placed atop the bed and a minimum of 4' of cover will be placed atop the
new septic tank.
The ground surface on the lot slopes from the middle of the lot both east and west at
grades approximating 2% to 5%. The new absorption trench will be constructed parallel
with the slope of the ground surface as much as possible in conformance with
Municipal requirements. The new septic system will be constructed 100' from all wells
and 100' from any surface water. It will also be constructed a minimum of 10' from any
· Lo't 3, Block 2, Greenland Subdivision
April 7, 2005
Page Two
water service in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
E 112~
lt4~h ~XAvenue
AREA HAP s~ ' ~ , '
.;REENLAND SUBDIVISION
LOT 3, BLOCK 2
27,000 S.F.
EAST 113TH AVENUE
8g'5,,,3'20"lr 100.00'
A.C. DRrVE ~)
Pr~Pe~sed
PROPOSED
BUI~ING
x
1,250 Gallon
Septic Tank
20' ~l
Depth ~sorption Trench
S 89'53'20"E 100.00'
EAST 114TH AVENUE
~..ZC.<L r. ^Nncr~a./
SITE PLAN
SCALE: 1' = 40'
LOT 3, BLOCK 2, GREENLAND SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom House 5' Wide Trench System
Parc. Rate: 6-15 Min./inch 1,250 Gallon Septic Tank
Application Rate: ·8 GPD/SF 4' Drainfield Rock
4 Bedrooms X 150 GPDI.8 GPD/SF (Application Rate) = 750 SF Absorption Area
750 SF/5 SF ' .5 (Red. Factor) = 75 LF Trench Length
THEREFORE: Construct a 75' Long x 5' Wide x 4' Effective Depth Absorption Trench.
Flow Line Elevation in Trenches to be 3' Below Odginal Ground Surface. Total Depth to be
7' Below Existing Ground. Provide 4' Cover Over Septic Tank and :3' Cover Over Trench.
2'6"
4'0"
3' Cover
,,,,,,/'~atural-~ Over Trench
Backfill
Geotextile
-- Fabdc
4" Perforated
PVC (Holes Down)
-- Drainfield Rock
TYPICAL 5' WIDE TRENCH SECTION
~.o SCA,E) .._'~;~ ..........
NOTE: Grade Area Over Trench to D~in Away. ~ .~.
Minimum 6 Separation From Bed~k. ..~.,~.....~.......~.....~
Minimum 4' Separation From Groundwater. ~
Minimum 100' Separation From Wells in the Area. ~'~[
Minimum 10' Separation From Water Se~ices. ~% No
Minimum 100' Separation From Sudace Water or Streams. '~,~..~.'"~
Pedormed For:
Legal Description: ~ "'r- ..~
7-
8-
9-
10-
11~
13-
18-
19-
20-
Mh nicipa'lity of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Waslewater Program
' 4700 South Bragaw St.
P.O. Box 195650 Anchorage, AK 99519-6550
www ci ah~horeoe ak.u~
(90?) 343.7904
Soils Log - Percolation Test
Date Performed:
,~' ~ L,jl~:~wnship. Range. Seotion:
Slope · .
I'1-t
I
· WAS GP, OUNO WATER
ENCOUNTERED?
· Read!ng
Site Plan
Net Time
~ ·
Water Net D~op
I~,.~ .'
I ~.~,~.
PERC HOLE DIAMETER
FT
.I I
' PERFORMED ~Y: ,/~ I !RTIFY THAT THIS TEST WAS
PERFORMED II'J ACCORDANCE WiTH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THtS DATE.· DATE:
2-
3-
4-
5-
9-
10-
11,
13-
14-
15-
18-
19-
20-
M~nicipa'lity of Anchorage
Development Services Department
Building Safety Division
On. Site Water and Wastewaler Program
4700 South Braga~v St.
P.O. Box 195650 Anchorage, AK 99519-$~50
(907) 343-7904
Soils Log - Percolation Test
Perc. <15 Min.'/I.n,
Slope
I 't
III
Date Pefformed:~
Township, Range, Section: ' :.
Site Plan
· WAS GROUNDWATER '1 .
ENCOUNTERED? ~ '*
· Dmz-.:4/7/05
Read!rig
Net 'rime J Depth tb Water Net D~op
-'~.' I ~".' ~
.~..IZ"
I · Date Gr6ss'iqme
I" ~ :,,~ -' I
I ~ .: ~'
I
I
FT 'AND
'1',
PERC HOLE Dt.~ME?ER
FT
PERFORMED BY: ,~ J lk"Y THAT THIS TEST WAS
PERF~RMED it``~ AC~c~RDANcE ~ITH A~L ~TATE AND MUN~C~PAL GU~DEL~NES ~N EFFECT ~N TH~S D~TE~ DATE:
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: (907)343-7904
On -Site Water & Wastewater Section Fax: (907)343-7997
Parcel ID 015-172-16
Certificate of On -Site Systems Approval
OSC241267
Expiration Date:
Legal description GREENLAND BLK 2 LT 3
Site address 4900 E 113TH AVE
Current property owner(s) BOYER MICAH JOHN & HOLLY RENEE
X The On -site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or conditions:
By:
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage,
Development Service Department (DSD) issues COSAs based upon representations provided by an
independent professional engineer. The Municipality of Anchorage is not responsible for errors or
omissions in the professional engineer's submittal.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
RMOOM
Development Services Department
On -Site Water & Wastewater Section
Ve L'9':Mfop
rJ 0"-'—
ANCHORAGE
Phone: 907-343-7904
Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 015-172-16
Complete legal description GREENLAND; BLOCK 2, LOT 3
Location (site address) 4900 E 113TH AVE., ANCHORAGE, AK
Current property owner(s) MICAH & HOLLY BOYER Day phone 907-240-1653
2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: 1101] Private Well R Private Well serving 2 dwelling units
El Private Well serving 3+ dwelling units F-1 Community Well or Public
F Water Storage
4. TYPE OF WASTEWATER DISPOSAL: FE-1 Private Septic F-1 Private Septic serving 2 dwelling units
R Holding Tank R Community Septic or Public Sewer
5. SEPTIC TANK: F-1 Steel 0 Plastic ❑ Concrete F-1 Fiberglass
Age NEW - See advisory if steel older than 20 years
6. ABSORPTION FIELD: R AWWTS R Bed F] Deep Trench RE Wide Trench [I Seepage Pit
Waiver request for:
Expedited review requested: F-1
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On -site staff
to verify the accuracy of the information provided.
COSA Fee $ Waiver Fee $
Date of Payment Z `/ Date of Payment
COSA #
4 -) C_ Waiver
e" _)
COSA Application —June 2022
COSA Checklist
Legal Description: GREENLAND; BLOCK 2, LOT 3
Parcel ID: 015-172-16
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system 1
A. WELL DATA
R Well log is filed with Onsite (or attached)
Date drilled 7/02/2005 Total depth 223 ft
Cased to 223 ft
❑ Sanitary seal is functioning correctly
R Wires are properly protected
Casing height (above ground) 1 g+ in.
Date of flow test for COSA 7/3/2024
Static water level at beginning of test 147 ft.
Comments
B. TANK DATA
Measured operating fluid level in septic tank NEW
Date of pumping NEW
❑ Required maintenance completed, if AWWTS
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) 817-11/26/24
❑ ALL standpipes present per record drawing
Total measured depth from grade 6.05 ft (max)
Measured depth to pipe invert from grade ft (min)
0 N/A — pressurized field.
Per record drawings, field is insulated.
❑ Monitor tubes go to bottom of effective.
If not, state depth into effective V i � Isy
❑ Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced _gallons date
Any rejuvenation treatment (past 12 months) NIA
If yes, enter date
Comments/Deficiencies:
Well production at time of test 3.5+ gpm
Water storage tank volume N/A gallons
Well disinfected for coliform test? ❑ Yes R No
❑ Coliform bacteria is Negative
Nitrate 0.412 mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L AN Arsenic less than MRL (ND)
Collected by GEG, LTD.
Date 6/25/24
C. LIFT STATION
❑ Required maintenance completed
Age of lift station NEW years
Lift station material PLASTIC
Comments:
Adequacy test date NEW
Results Q Pass
Fluid depth prior to test 0 in
Water added 0 gal
New fluid depth 0 in
Elapsed time 0 min
Final fluid depth 0 in
Absorption rate 600+ gpd
FIELD STATUS — POST RECOVERY
Effective depth (per record drawings) 24 in
Effective depth used 0 in
Effective depth remaining 24 in
COSA Checklist June 2022
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100'
Community Sewer Manhole/Cleanout > 100'
© Yes
if No
ft
© Yes
if No ft
Neighboring Tank > 100' ❑i Yes
if No
ft
Private Sewer/Septic Line > 25' Q Yes
if No ft
Absorption Field on Lot > 100' M Yes
if No
ft
Holding Tank > 100' n Yes
if No ft
Neighboring Absorption Fields > 100'
Animal Containment > 50' 0 Yes
if No ft
❑i Yes
if No
ft
Community Sewer Main > 75' Yes
if No
ft
Manure/Animal Excreta Storage > 100'
0 Yes
if No ft
❑ N/A — Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
on Yes
if No
ft
Surface Water > 100'
0 Yes if No ft
Tank to Property Line > 5'
© Yes
if No
ft
Wells on Adjacent Lots:
Field to Property Line > 10'
❑ Yes
if No * 1
ft
Private Wells > 100'
(Q Yes if No ft
Water Main > 10'
Q Yes
if No
ft
Community Wells > 200'
0 Yes if No ft
Water Service Line > 10'
❑ Yes
if No
ft
If tank or field is under driveway comment below
F. ENGINEER'S COMMENTS
*LOT LINE WAIVER GRANTED (WR#OSV241030)
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on -site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm Gamess Engineering Group, LTD. (GEG) Phone 907-337-6179
Engineer's Printed Name Jeffrey A. Garness Date
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in
accordance with the guidelines and regulations established by the Municipality of Anchorage and industry
practices. The reported results describe the condition of the system/s on the date/s of the evaluation.
Separation distances
oa600��
were measured to readily identifiable features. Hidden defects or encroachments may
exist that were not identified during the evaluation. The operational life of all wells and septic depend
systems
upon a variety of variables, including (but not limited to) soil conditions, groundwater levels (that may fluctuate
during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing
the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test
*; L) T y Q
results do not
future
.:. ..... .... ..........
0
3uarantee performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding
the future performance of the well or septic system. GEG makes no representation whether an alternative well
G
or septic system can be installed on the property in the event either of the current systems fail to perform
adequately in the future. The this is for
ey rness:- G
content of report the sole benefit of the person/party that retained GEG
to perform the evaluation. Reliance upon the information in this by
�' O
OQ ' CE— 79 3
provided report any other person or party
(including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever.
6Ps • c�Qp
jr?-. l'f�•2'
�f�� �Ao
e
COSA Checklist June 2022
-
LICENSE©O �ofess-,oa1=>
MEccaea OO0000
Cya+45
MUNICIPALITY F ANCHORAGE
. t� I
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel 1. D. 015-172-16
1. GENERAL INFORMATION
Complete legal description Greenland B2 L3
Location (site address) 4900 E 113th Ave
Expiration Date: 3-30-20210
Current property owner(s) Brian & Julie Buck Day phone
Mailing address
4900 E 113th Ave Anchorage, AK 99516
Real estate agent Day phone
2. TYPE OF DWELLING:
I] Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
4. TYPE OF WATER SUPPLY:
,),50
TYPE OF WASTEWATER DISPOSAL:
Private Well
0
Private Septic
I -XI
Water Storage
❑
Holding Tanki
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer'
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $
,),50
Date of Payment
�alal�9
Receipt Number
COSA #
05C_ 1'%oS
Waiver Fee $
i
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures
outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or
wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated
herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State
codes, ordinances, and regulations in effect at the time of installation.
In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA
COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time
of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on
the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not
guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot
provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole
benefit of the owner listed above. Reliance on this report by another person is at their own risk. Pannone Engineering Services LLC highly
recommends buyers hire their own engineer to evaluate this report.
Name of Firm Pannone Engineering Services
Phone (907) 745-8200
Address P.O. Box 1807 Palmer, AK 99645
Engineer's Printed Name Steven R. Pannone P.E.
Date
OF A�,
6. DSD SIGNATURE
TH
• . .... — . .. ...:
System #1 Approved for bedrooms
Steven Ponnore
System #2 Approved for bedrooms
��¢� 3 - CE 8749
r�
Disapproved
Conditional approval for bedrooms, with the
following stipulations:
Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
i
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA Checklist blue sheet
Legal Description: Greenland B2 L3
If more than 1 septic system on lot: COSA Checklist # 1 of 1
A. WELL DATA
FE -1 Well log is filed with Onsite (or attached)
Date drilled 713/05
Total depth 223 ft
Cased to 223 ft
❑ Sanitary seal is functioning correctly
© Wires are properly protected
Casing height (above ground) 18°+ in.
Date of flow test for COSA 7217'19
Static water level at beginning of test 155.6 ft
Comments
B. TANK DATA
Age of tank(S) 5111105 years
Tank type/material s"Wst °'
Measured operating fluid level in septic tank 50"
FW Standpipes/foundation cleanout per record drawing
Date of pumping 12/20/19
D. ABSORPTION FIELD DATA Wide Trench
Which system tested (date installed) 5/11/05
Al ALL standpipes present per record drawing
Total measured depth from grade 9.5'68 ft (max)
Measured depth to pipe invert from grade 6.3-3.5 ft (min)
❑ N/A — pressurized field
F0 Monitor tubes go to bottom of effective_ If not, state
depth into effective
FO -1 Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Comments/Deficiencies:
COSA Checklist yellow sheet
f
Parcel ID: 015-172-16
Structure served by this system 1
Well production at time of test 2.45 gpm
Water storage tank volume n/a gallons
Well disinfected for coliform test? ❑ Yes 0 No
X Coliform bacteria is Negative
Nitrate •5 mg/L E]Nitrate less than MRL (ND)
Arsenic ug/L X Arsenic less than MRL (ND)
Collected by Pannone Engineering
Date of Sample 1217/79
C. LIFT STATION
❑ Required maintenance completed
Age of lift station years
Lift station material
Comments:
Adequacy test date 1217119
Results [DPass For 4 bedrooms
Fluid depth prior to test 19/19 in
Water added 600 gal
New depth 23/25 in
Elapsed time 1440 min
Final fluid depth 19/19 in
Absorption rate '600 gpd
Any rejuvenation treatment (past 12 months)
If yes, enter date
MAS
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
0
Yes
Community Sewer Manhole/Cleanout > 100'
Q✓ Yes
if No
ft
❑✓ Yes
if No ft
Neighboring Tank > 100' M✓ Yes
if No
ft
Private Sewer/Septic Line > 25' E] Yes
if No ft
Absorption Field on Lot > 100' Q✓ Yes
if No
ft
Holding Tank > 100' R1 Yes
if No ft
Neighboring Absorption Fields > 100'
F-1 Yes if No ft
Water Main > 10'✓Q
Animal Containment > 50' Q Yes
if No ft
0 Yes
if No
ft
Q Yes if No ft
Water Service Line > 10'
✓0
Yes
if No
Manure/Animal Excreta Storage > 100'
If septic tank is under driveway
Community Sewer Main > 75' MV Yes
if No
ft
M Yes
if No ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
0
Yes
if No
ft
Surface Water > 100'
Q Yes if No ft
Property Line > 5'
F71
Yes
if No
ft
Wells on Adjacent Lots:
this system is operating at 67% used.
Absorption Field > 5'
❑✓
Yes
if No
ft
Private Wells > 100'
F-1 Yes if No ft
Water Main > 10'✓Q
Yes
if No
ft
Community Wells > 200'
Q Yes if No ft
Water Service Line > 10'
✓0
Yes
if No
ft
If septic tank is under driveway
comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10' Yes if No ft
If absorption field is under driveway comment below
Property Line > 10' ❑ Yes if No 1.0* ft
Wells on Adjacent Lots:
Water Main > 10' Yes if No ft
Private Wells > 100' []✓ Yes if No ft
Water Service Line > 10' Yes if No ft
Community Wells > 200' Yes if No ft
Surface Water > 100'✓CJ Yes if No ft
F. ENGINEER'S COMMENTS
* Waiver on file. Based on adequacy test,
this system is operating at 67% used.
Reverse or flat grade from septic tank to drain field (2.5" of standing water in double
clean out).
G. ENGINEER'S CERTIFICATION OF
1 certify that t have determined through field inspections and review eco -
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date. % {� 1Z2 • • • •
Steven 10onnone
CL 8,149
��-
COSA Checklist yellow sheet
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99507
www. muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 015-172-16
GENERAL INFORMATION
Complete legal description
Location (site address)
COSA #
Expiration Date:
Lot 3, Block 2, Greenland Subdivision
4900 East 113th Avenue Anchorage, AK 99516
Current Property owner(s) Fillipe and Jody Clark
Mailing address 4900 East 113th Avenue Anchorage, AK 99516
Day phone
Lending agency
Day phone
Mailing address
Real Estate Agent
Day phone
Mailing Address
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBEROF BEDROOMS: Four (4)
TYPE OF WATER SUPPLY:
Individual Well []
Individual Water Storage []
Community Class __ Well []
Public Water System []
TYPE OF WASTEWATER DISPOSAL:
Individual On;site []
Individual Holding Tank []
Community On-site []
Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or ClasS C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Phone 522-7773
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
DSD SIGNATURE
~ Approved for
Disapproved.
bedrooms.
Date 4/5/2o
Conditional approval for
bedrooms, with the following stipulations:
By:
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
X
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
_~_~~Original Certificate Date:
(Rev. 11/05)
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 Elmora Road
P.O. Box 196650
Anchorage, AK 99507
www. muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: Lot 3, Block 2, Greenland Subdivision
A. WELL DATA
Well type Private
Date completed 7/2/0.5
Total depth 223 ff. Cased to 223
FROM WELL LOG
Date of test 7/2/2005
Static water level 152
Well production 40
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 mL
Arsenic: N/D ug/I
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel
Tank size 1,250 gal.
Foundation cleanout (Y/N) Y
Date of pumping 4/6/2011
C. ABSORPTION FIELD DATA
Date installed 5/11/2005
Length 88 ft.
Total depth 6-8 ft.
IfA, B, or C provide PWSID # ~
Sanitary seal (Y/N) Y
g,p.m.
Nitrate .10 mg/L
Date of sample: 3/25/2011
Number of Compartments Two
Depression over tank (Y/N) N
Pumper Denali Sewer and.Drain
Soil rating (g.p.d./~ or ~/bdrm) .s GPD/SF
Width 5 f.
Eft. absorption area 758 ft2 Monitoring tube .
Date of adequacy test 3/26/2011 Results (Pass/Fail) Pass
Fluid depth in absorption field before test ~ 17.5 in.
Elapsed Time: 1,308 min. Final fluid depth' 17.5
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N
Parcel ID: 015-172-16
Well Log (Y/N)
Wires properly protected (Y/N)
Casing height (above ground)
AT INSPECTION
3/26/11
145 ff.
8.2 g.p.m
Y
>18 in.
For Four bedrooms
Water added 667 gal. New depth 23 in.
in. Absorption rate >= 600 g.p.d.
If yes, give date
System type. Wide Trench
Gravel below pipe 3 ft.
,Y Depression over field N
Date installed 5/11/2005
Cleanouts (Y/N)
High water alarm (Y/N)
Other bacteria o colonies/100 mL
Collected by: A. Harala
LIFT STATION
Date installed
"Pump on" level at
Datum
in.
E. SEPARATION DISTANCES
Size in gallons
"Pump off" level at
Cycles tested
SEPARATION DISTANCES FROM WELL ON LOT TO:
in.
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
Sewer/septic service line
Animal containment areas
N/A
> 100'
>100'
>25'
None ~ ~) ~''
Manhole/Access (Y/N)
High water alarm level at
Meets alarm & circuit requirements?
On adjacent lots >1oo'
On adjacent lots >1oo'
Public sewer manhole/cleanout
Holding tank N/A
Manure/animal excrete storage areas
in,
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >5'
Water main N/A Water service line >10'
Wells on adjacent lots >lOO'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
N/A
None / O 83 '
Property line 1'
Water Service line >1o'
Curtain drain None Noted
Absorption field >5'
Surface water >100'
Building foundation >10' Water main >10'
Surface water >100' Driveway, parking/vehicle storage >25'
Wells on adjacent lots >100'
F. COMMENTS: Lot line Waiver Issued.
G. ENGINEER S CERTIFICATION*
~w~w of MuniCipal m~s that the above sy~ems am in
confo~an~ w~h MOA COSA guidelines in e~ on this date.
EngJn~r's Printed Name Michael E. ~demon, P.E.
Date 41512011
COSA Fee $
Date of Payment
Receipt Number
(Rev. 11/05)
Waiver Fee $
Date of Payment
Receipt Number
SGS Reft# 1111098001
ClientName Anderson Engineering Printed Date/Time 03/31/2011 8:17
Project Name/# Greenland Subd L3 B2 Collected Date/Time 03/25/2011 9:12
Client Sample ID Greenland Subd L3 B2 Received Date/Time 03/25/2011 13:00
Matrix Drinking Water Technical Director Stephen C. Ede
PWSID 0
SampLe Remarks:
Allowable Prep Analysis
Parameter Results LOQ Units Method Container ID Limits Date Date Init
Metals by ICP/MS
Arsenic ND 5.00 ug/L EP200.8 C (<10) 03/25/11 03/29/11 NRB
Waters Department
Total Nitrate/Nitrite-N 0.328 0.100 mg/L SM20 4500NO3-F B (<10) 03/30/11 AYC
Microbiology Laboratory
E. Coli Negative 1 100mL SM20 9223B A 03/25/11 DLC
Total Coliform Negative I 100mL SM20 9223B A 03/25/ll DLC
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700, Elmore Road
P.O. Box 196650
Anchorage, AK 99507
www. muni. org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROMAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D._ 015- I~,~L- I~
1. GENERAL INFORMATION
Complete legal description Lot 3. BIoc~ 2, Greenland Subdivision
*Location (site address) . 4900 Eas~ 113th Avenue Anchorage, AK 99516
cos^# g O I q
Expiration Date: R
Current Property owner(s), Jennifer R. Toomet-
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing Address
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: Four (4)
4900 East 113th Avenue Anchorage. AK 99516
Day phone
Day phone
Day phone.
3. TYPE OF WATER SUPPLY:
Individual Well []
Individual Water Storage []
Community Class Well []
Public Water System []
TYPE OF WAS'I e:WATER DISPOSAl':
Individual On-site []
Individual Holding Tank IJ~
Community On-site []
Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site S terns
Approval (COSA) based only upon the renresentations ,-iv~- , .......... '. ys
u ~- f- paragraph n oy an Inaepenaent professionat civil
engineer registered in the State of Alaska. Certificates of On-Site Systems Approvat are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposat and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I varify that my investigation.
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (am) safe. functional and adequate
for the number of bedrooms an(ttype of structure indicated herein. I further varify that based on the information
obtained, from the Municipality of Ancho=ge flies and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(am) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect al:the time of installation.
Name of Firm Andemon Engineering
Address P.O. Box 240773 Anchorage, AK 9~524
Engineer's. Printed Ns. me Michael E. An(lemon, P.E.
5. DSD SIGNATURE
~ / Approved for J~
Disapproved.
Conditional approval for
Phone
,,d{((ff((((O'~ .
WATER AND : m=
~ : WASTEWATER:
.,,-4 ..... - ~5~ ~
, HIII))H~
Attachments:
COSA Checklist X '
Septic System Advi-~ory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Pregram
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99507
www.muni, org/onsite
(907) 343-7904:
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: _L~t 3, Block 2, Greenland Subdivision
A. WELL DATA
Well tYPe .Private IfA, B, or C provide PWSID
Date completed .7/2/05 Sanitary seal (Y/N)
Total depth _223 ft. Cased to .223 fl.
FROM WELL LOG
: 7/2/2005
g.p.m.
Nitrate .254 rng/L
Date of sample: _5/'//08
'Number of Compartments ..Two
Depression ove~ tank (Y/N) N
,Pumper Denarl Sewer and Drain
Parcel ID 015-172-16
Date of test
Static water level t52
Well production 40
WATER SAMPLE RESULTS:
Coliform 0 colonles/100 mL
Amenic: N,13 ug/l
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material. S~ttc/St~el
Tank size _1,250 gal. '
Foundation cleanout (Y/N) Y
Date of pumping _5/5/'2008
C. ABSORPTION FIELD DATA
Date instatled ? 1/2005
Length: 88 , ff.
Total depth. 6-8 ft.
Well Log ('Y/N) V
Wires propedy protected (Y/N) y
Casing height (above ground) >18
AT INSPECTION
5/10/'2oo8
5 2 g.p.m.
in.
Other bacteria .o colonies/100 mL
Collected by: _J. Davis
Date installed s/11/2o05
Cleanouts (Y/N) y
High water alarm (y/N) .... N
Date of adequacy test 5/10/o8 Results (Pass/Fail). Pass For .Four bedrooms
Fluid depth in absorption field before test__ 8 ' in. Water added 650 gal. New depth,
'Elapsed Time: 1,440 min. Final fluid depth , ~ 8 in. Absorption rate >= 600
Any rejuvenation tmab'nent (past 12 mo.) (Y/N & type) N If yes, give date
Soil rating (g.p.d./ft~ or ft=/bdrm) .8 GPD/SF System type W~de Trench
Width., 5 ft. Gravel below pipe 3
Eft. absorption area .758 'ft~ Monitoring tube. Y Depression over field
in.
g.p.d.
Do UFT STATION
Date installed
'Pump on' level at in.
Datum
E. SEPARATION DISTANCES
Size in gallons
"Pump off' level at
Cycles tested
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank~iff station on lot >1oo'
Absorption field on lot >1oo'
Public sewer main NIA
Sewer Iseptic service line >25'
Animal containment areas None
in.
Manhole/Access (Y/N)
High water alarm level at.
Meets alarm & circuit requirements?.
tn.
On adjacent lots >10o'
On adjacent lots >1o0'
Public sewer manholelcleanout
Holding tank N/^
Manure/animal excrete storage areas
NIA;
None
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >5'
Water main N/A Water service line >10'
Wells on adjacent lots >100'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 1'
Water Service line >10'
Cuff,.3in drain None Noted
Absorption field >S'
Surface water >100'
, Building foundation >10'
Surface water. >100'
Wells on adjacent lots >100'
Water main >10'
Driveway, parking/vehicle storage >25'
F. COMMENTS: Lot line Waiver Issued.
G. ENGINEER'S CERTIFICATION
I ce~'fy that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.F_
Date 5116/2008
COSA Fee $
Date of Payment
Receipt Number
(Rev, 11/o5)
Waiver Fee $
Date of Payment
· Receipt Number
P-268
GREENLAND SUBDIVISION
LOT 3, BLOCK 2
27,000 S.F.
EAST 1.15TH AVENUE
S 8g'53'20'£ 100.00'
28.8' L
EXISTING
BUILDING
27.0'
i o
I
,
! ·
S 89'53'20'E 100.00'
EAST 114TH AVENUE
AS-B U I LT I HEREBY CERTIFY THAT I HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO
GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. i
SURVEYING,' LLC IT IS THE RESPONSIBILITY OF THE OWNER TO;
JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS,
4726 WEST 88TH AVENUE COVENANTS OR RESTRICTIONS WHICH DO NOT
ANCHORAGE, ALASKA 99502 APPEAR ON THE RECORDED SUBDIVISION PLAT.
PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA
GRID DAT~ HEREON BE USED FOR CONSTRUCTION OR FOR
2636 8/30/2005 ESTABLISHING BOUNDARY OR FENCE LINES.
ANCHORAGE RECORDING DISTRICT, ALASKA
r.8. JOB NO.
05-12 ~ CS32 NOTE: NO CORNERS SET THIS DATE.
Municipality of Anchorage
Development Services DBpartment
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw SL
P.O. Box 196650 Anchorage. AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 015-172.16
1. GENERAL INFORMATION
Complete legal description* Lot 3. Block 2, Greenland Subdivlslon
Location (site address or directions) . 4841 East lt4~' Avenue
HAA # DSD~tq ~
Expiration Date: _/o~-. -~,..- 0 ,.~
Current Property owner(s). Merit Homes
Mailing address
Lending agency
Mailing address
. P.O. Box 111982 Anchorage, AK 99511 ·
Day phone .334-9233
Day phone,
Real Estate Agent
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup.
NUMBER OF BEDROOMS: _Four r4)
Day phone
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class.
Public Water System
Well
[]
[]
[]
[]
TYPE OF WASTEWATER DISPOSAL:
Individual On-site []
Individual Holding tank []
Community On-site []
Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given In paragraph 5 by an Independent professional civil
engineer registered In the State of Naska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties sewed by a single family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties sewed by a private or Class C well and may be reissued with
new water sample results less than 30 days old. (Certificates may be reissued for a pofiod of up to one year with
valid water samples.) Certificates are valid for one year for properties sawed by Class A or B wells or a public water
system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's
4. STATEMENT OF INSPECTION BY ENGINEER
As certitied by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the
site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further vedfy that based on the information obtained from the
Munidpality of Anchorage files and from my investigation and Inspection, the an-site water supply and/or
wastewater disposal system is(are) In compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm. Anderson Engineering
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
Phone 522-7773
Date 911/2005
5. DSD SIGNATURE
Approved for ~
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Additional Comments
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
X
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date: c/..~.. _ O..~
(Rev. t2,'00)
Municipality of Anchorage
Development Services Department
Bmldlng ~af~ty Oiv~lon
Or~lte Water & Wastmrater Program
4700 Sou~ Bragaw 6L
P.O. Box 196650 Ancl~orage, AK 99519-6650
www.cl.anchorage.ak, us
(907) 343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Das~¥~on:
A,, ~ DATA
Well type Prlwta
Date completed ;rff~0~
Total deplh
Date of test
SteUc water level
Well produc~on
WATER SAMPLE RESULTS:
· Coliform, ~ colonieS100 mi.
Date of .ample:
B. SEPTIC~IOLDING TANK DATA
Tank Type/Material b~c/Steel
Tank size ~ gal.
F~daUon deanout (Y/N)
Date of pumping
C. ABSORPTION FIELD DATA
Date iflstelted ~/tl/2009
Total dep~ 6-~ ft.
Date of adaquacy test
Lot 3. Block 2. Greenland 8ubdlvl~t911
Parcel ID: 0t~-"172.11~
If A, B, or C pmvtde PVV~ID #.
Sanlte~y seal (Y/N) Y
Casadm 223 IL
FROM WELL LOG
t52 ft
,~1 g.p.m.
We, Log (Y/N) y
Wlra pmpe~ protected (Y/N) y
Casing height (above ground) Z4
AT INSPECTION
g.p.m.
Nitrate .10 mg./I.
Number of Compartments Z
Depression over tank (Y/N) N
Pumper New Conltmctlon
,0 colonies/100 mi.
Date installed 5/tt/2005
Cmanoum (y/N) y.
High water alarm (Y/N)
8ollm0ng (g.p.d./~or~/tx:lrm) JGPD~F System (ype WldeTmnch
ff VVldlh ,0 ff. Gravel below pipe ]1
Eft. absaq:~On ama ~i8 ~ Monitoring tube Y Dapre~ion ove~: field'N
Results (Pass/Fall)
Fluid depth in absofplton field before test in. Water added gal.
Elapsed T~me: min. Final fluid depth in. Atmori~on fate >-
Any rejuverm~on Imatmant (past 12 mo.) (Y/N & type) H If yea, give date
New depth in.
g.p.d.
D, UFT 6TATION
Date installed
'Pump on' level et in.
Datum
E. SEPARATION DISTANCES
Size in gallons
"Pump off' level at in.
Cycles tested
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lilt station on lot >1~
Absorpfien fiekl on lot
Pubftc ~ewer main FUA
Sewer les~c esrvtce line >25'
Manhole/Access (Y/N)
High water alarm level at
Meats alarm & ,J,~.tt mqulmmer~?
On adjacent lots >IQQ'
On adjacent lots >IQQ'
Publlo ~ewer manhole/cleanout FUA
Holding tank FUA
in*
HAAFee S./~'7 ~ ~. ,~r# WaNerFee$ '-/I?~' ~--
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >[r Property line ~ Absorption field >~'
Water main N/A Water service line >1~' Surface water >t00'
Wefts on adjacent lots >100'
SEPARATION OISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line t'* Building foundaUon >1l}' Water main
Water Service line >IQ' Surface water >t00' Driveway. paddng/vehicle ~Orage
Cudain drain None Noted Wells on edJacent lots >100'
F. COMMENTS
"See Lot Line W~wf,
o. .......
Enginesr'e Pdntml Name Mlch.el E. Anderson. P.E. ~'~ ' ~'"~/'~~"'~...
09-01-05;12:01
;907 561 5301 # 2/ 4
SGS Ref.~
Client Name
l~roJeet Name/#
C~ent Snmi~]e ID
105~439001
Dr[~J~ g Water
All DatcJ/Tlmes are Alaska $tnndard Time
l'rtnted D~te/Tlme 08/29/2005 11:06
Collected Datefl'lme 08/23/2005 10:45
Received D~t.e/Time 0~/23/200.5 1~:00
Technical Dlrector Ste~hen C. Ede
Sam~le Remarks:
'Hit~te-N 0.100 U 0.100 m,~r.,
EPA 353.2 B (<-I0) 08~3/05 AZS
l,f. ie~'ob'l ol o c~y Labo=a~o=¥ ~
Total Col/form ~"~C.w/ coVl00:nL SM20 g222B
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
September 1, 2005
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Su~e~:
Lot 3, Block 2, Greenland Subdivision
Separation Distance Waiver
Absorption Trench to Lot Line
Dear On Site Services Engineer:
The absorption trench on the subject lot was constructed within 1' of the west lot line to
accommodate the construction of the new house and to take advantage of the
favorable topography of the lot's surface. In addition, soil conditions on the lot made it
necessary to lengthen the trench and shallow the effective depth. A memo to the City
was forwarded on May 11, 2005 advising of the field conditions and explaining the
necessity of the lot line waiver.
The placement of the absorption trench within 1' of the west property line will have no
impact on the surrounding lots and will not encroach into areas reserved for septic
systems or wells. We therefore request a waiver be issued allowing the trench to be 1'
from the west property line.
Sincerely,
Michael E. Anderson, P.E.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Watcr and Wastcwatcr Program
4700 Bragaw Strc~
P.O. Box 196650 Anchorage. AK 99519-6650
www. cl.anchorage, ak.us
(907) 343-7904
Waiver Review Worksheet
WRY: 050068 PID~:015-172-16
HA#: 05044~ Permilg:
Date Received: 9-1-05
Legal Description: Greenland Block 2 Lot 3
Eng{neen Anderson Enaineerina
P,O. Box 240773 Anchoraae Ak. 99524
Applicant: Merit Homes
Waiver Requested: 1 foot separation distance absorption field to DrODeftv line,
Criteria: C-:-:-:-:-:-:-:-:-:~ ~ o g y Points:
A. Water Table
B. Soil SorptJon
C. Permeability
D. Water Table Gradient
E. Horizontal SeparaUon
Total:
Waiver is Granted: (.,.,,'/ Waiver Is not Granted:
Ust Condi§ons or Reasons for above:
Rec#: ~.1~5 Amount: $175 Date Paid: 9/2/2005