Loading...
HomeMy WebLinkAboutTHE TABLELANDS BLK 6 LT 3lend Block 6 Lot 3 #0§!-80!-26 ii ti Lo ii NN li ii N Z1\\`� <<\ _ o N O O (') m •r M ��i G L C C • • El C C N E'i/• -O LL Y C C Q • • E 07 V• O O_ O ~ Q I • I • • N Nm E n _0 m 2 w o w o w Q ) O o / m r �. r) Z ❑ 0 o C 'o 6 Q J O C N 7 fU N CO `b •• • �' CO LL LL C Y O d a c� N N E oEl o m 1 u O O N i cn m m z .. a Q 0 o O �_ m m x U 'V• M °o E J W c O r) 0 rnN m z Q >_ N ti N LL Z � li — U � �cn E m 0 ® w W U J o J Q C .Q O \ �O o 2 -- H °' Z �❑ o w �2rn Ln . LJ o Z O W O g Y J _�. m m cV cn ali � >� �� o `� U_ o O LL W a( W> Z m W o �d E C) n. o �, o oQ� a ® a o) F- g J O aD L) U) z~ O❑ ° 3 Y� o o v o =a `�ca z❑ w z '_ € a Q a ° m W 0_ m a in a o ii c� a� I- 6 J co Z a d w c0 � ZO `• Y L I_ L F- 0 a Q N 3 •c + LO ¢ r V d c� a � E U) J N Z m N — W = v o c LU 3 H o .. o c...Y Q1 W ~ M D j W0 E Y o c ..._ L'- c •= " W L>L m O O + cts N a U) (n c 5 O O L(i O r Mo rn aoi °' N •c a z_ O O d s W U) ..._...._. c C Z a w 00 V - o.2 o 0 0 o w w a 0 N C) ca zLO u H N O U) o LU = w il Q o a@ o o + oCD CD LU o CD N 2 co Fn U)— E® 2 w W m O� 0 3 0 U z a m �, z° _ = w a a _ 76 0� - z i 0.. �? 0 U O Z m ~moo d J 0 0 m m v` a� �Q (D F- Q Qp c t7 ow c d E o 0 E m Q c c a) Q N 3 d 0 m z� 2' M C/5 (N r d W� -'j 2 W- o � W N o �i � � 0 � y O U U) a 4-B E D R O O M RE S I D E N C E GRE E N HOU S E FIRST WATER CONSULTING PID:051-801-26 PERMIT:OSP241174 4-B E D R O O M RE S I D E N C E GRE E N HOU S E PID:051-801-26 PERMIT:OSP241174 FIRST WATER CONSULTING MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241174 Work Type: Septic Upgrade Tax Code Number: 05180126000 Site Legal Address: THE TABLELANDS BLK 6 LT 3 G:1559 Site Mailing Address: 23005 WHISPERING BIRCH DR, Chugiak Owner: EDGE MATTHEW C & HEATHER M Design Engineer: FIRST WATER CONSULTING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 7/19/2024 7/19/2025 40017 Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: The Engineer is required to do an additional percolation test prior to construction of the septic field. Please submit stamped and signed results with the As -built Inspection Report. If the results require a design change, construction of the system will stop pending On -Site review and approval. Received By: �-r Issued By: k-_ Date: / Date: 4 ON -SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051-801-26 Property owner(s) MATTHEW & HEATHER EDGE Day phone _ Mailing address 23005 WHISPERING BIRCH DRIVE, CHUGIAK, AK 99567 Site address 23005 WHISPERING BIRCH DRIVE, CHUGIAK, AK 99567 Legal description (Sub'd., Block & Lot) THE TABLELANDS BLOCK 6, LOT 3 Legal description (Township, Range & Section) Lot Size 40,017 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (Z all that apply) Absorption Field Rx Initial R Single Family (SF) (w/wo ADU) Septic Tank El Upgrade Duplex (D) ❑ Holding Tank R Renewal Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: $45q ±D Waiver Fees: Date of Payment: Date of Payment: Receipt Number: Receipt Number: Permit No. C25 PZ ti 117 y Waiver No. GL\Developrnent Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com ! !! June 27, 2024 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC SYSTEM UPGRADE PERMIT LEGAL: THE TABLELANDS BLOCK 6, LOT 3 The property owner has requested we obtain a permit to upgrade the failed septic system of the above referenced lot. We propose to install the alternate reserve site with two shallow 5’ wide trenches and a pump basin to serve the existing 4-bedroom residence. If the integrity of the tank is verified as compromised or owner requests, a 1500-gallon STEP tank will be installed in lieu of the pump basin. The design is based on the MOA record test hole data (TH#1 & TH#2 – Michael E Anderson, PE in July 2004). Per this MOA data, the shallowest groundwater was observed during test hole excavation at 12’ & at 9’ during monitoring. The slopes are moderate or flat at 0-2% at the proposed upgrade location. The lot and area are served by public water. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241174, Curtis Townsend, 07/22/24 Fist Water CON S U L T I N U f 13030 Sues Way, Anchorage, AK 99516 907-350-9566 / firstwaterAK@gmail.com August 9, 2024 Municipalities of Anchorage On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: SEPTIC SYSTEM UPGRADE PERMIT — OSP241174 LEGAL: THE TABLELANDS BLOCK 6, LOT 3 To avoid moving a shed and losing some tall trees, we have conducted the recent test holes and attached is the modified design that accounts for a 6' separation between monitored groundwater and the bottom of the proposed absorption field with a total depth of 4' from grade, which is the same total depth of the original and existing approved septic absorption field. Other items of the previously permitted design remain the same. The slopes are moderate or flat at 0-3% at the proposed upgrade location. The lot and area are served by public water. The design will not impact any of the neighboring properties. Please contact us if you have any questions. Sincerely, (�A6 L^%_ Curtis Huffman, P.E. Firsl Wal"L �t' 1IEMAIf�R �lil „N+-IYG DESIGN CALCS: 4BR X 150 GPD = 600 GPD 600 GPD/0.45 GPD/SF = 1,334 SF SAS 1,334 SF / 5'W (RF 0.78) = 209 FT. TRENCH USE 4 TRENCHES — 53'(L) X 5'(W) X 1.5'(ED) NO SLOPES >25% WITHIN 50' TOTAL MAX DEPTH FORM EXISTING GRADE: —4' OF PROPOSED FIELD. NOTES, STAKE PL, ESMTS, WELL RADII & OTHER ENCROACHMENTS PRIOR TO C❑NST, IF PRESSURIZED USE 212 LF 1 1/4" PVC WITH HOLES ® 3' SPACING (TYP). �' pA BTA1E tali. iti PR10rt m-, V pp1. c�a� \fir aNst BLOCK 6. LOT 2 p RETLW . Mu. nE / B+ TO FEiDSWT yam. TN24.1 ' �p Y 4T TDonqm TRT+aI \ y RAT cow, YT mi ,> E705TE102D-TEAR MDa1m\ NO WELLS WITHIN TA"` INWOM 200' OF PROPOSED NSTALL A PUMP IIIAMBARN lO w ma's : oft I'�°" SEPTIC SYSTEM. ,SOD-DA1. � 3" �T,D T. \ Tx24 2 ./ Dr."m N snr TO NEW * oDs M D AMRB'D0N i41D4 PB BLOCK 6, LOT 4 c\�r 1 MEPoFT C1048N0 FOO \ BEFORE TANK. \ Y IXIRESDENCE rfj9 �1- BLOCK 6, LOT 3 / A F�.41 WAAPPORX TER C �E'jl'tF \ LOWE mart TO *NOTE: ELEVATIONS WERE TAKEN & \ tiIV DEPENDING ON THE RUN THROUGH THE Q ABSORPTION FIELDS, GRAVITY FLOW MAY WORK EXISTING FIELD & TO THE PROPOSED a / V� TO THE PROPOSED FIELDS. IN THIS CASE & IF THE EXISTING SEPTIC TANK INTEGRITY IS FOUND SOUND, 3 SPUTTERS WILL BE ADDED (1 \ / A? FOR THE MAIN FLOW LINE & 1 OTHER EACH / A TO SERVE 2 TRENCHES) ALONG WITH TYPICAL CLEAN OUTS AT THE ALL TRENCH ENDS. 3 THE TABLELANDS BLOCK 6, LOT 3 SUPPORT#SERVICES: OFF\ PREPARED FOR: �'�� ` ' , 23005 WHISPERING BIRCH DRIVE `T" ANCHORAGE, AK 99567 * g TH* CHUGIAK, AK 99567 FIRST WATER CONSULTING DATE: 8/9/24 �` pis xuffmaLn SURVEY: Atf 13030 SUES WAY DRAWN FWCSALDI , CE 128991 �w os/o9/24 ANCHORAGE, AK 99516 SCALE: 1" = 50' ' 907-350-9566 FirstWaterAKOgmail.com PAGE: 1 OF 2 ��`` DESIGN DETAILS: DUE TO ELEVATIONS A PUMP BASIN *MAY NEED TO BE INSTALLED AFTER THE EXISTING TANK. MAINTAIN 10'+ FROM FOUNDATION, 200' TO WELLS, 5' TO FIELD & DECK SUPPORTS WITH 4' OF COVER OR INSULATION. INSTALL 4 53'L x 5'W x 1.5'ED TRENCHES —4' FROM GRADE w/ INSULATION & 2'+ OF COVER MAINTAINING 200' TO WELLS / SURFACE WATER, 10' TO LOT LINE,.... INSTALL PER AMC 15.65, 15.55, & MASS... TANK BEDDING, SEPARATIONS, MATERIALS, �O �DSTAKE ESMT. °0Z ,, & PL PRIOR TO/ s� CONST. BLOCK 6, LOT 2 / EXISTING SHED — W/ NO FOUNDATION WILL REMAIN & WILL BE \ 5'+ TO FIELDS. i�cyy MT ' 0\� T \ �8. TH24-1 MT / MAINTAIN B'+ l�e 0- 3 / STAKE ESMT. & PL PRIOR TO CONST. MT \ I MT \ O�T \ TH24-2 BLOCK 6, LOT 4 \ TH2 MT TO EXISTING TRENCH. M �8. FLAT TH1 (MEA) j RIFY EXISTING 20—YEAR OLD STEEL \ SEPTIC TANK INTEGRITY & MT INSTALL A PUMP BASIN TO NEW ABSO 71ON FIELD WITH DIVERTER PRIOR TO BO MT ABSORPTION FIELDS OR DECOMMISSION EXISTING S.T. & INSTALL NEW 1500—GAL HDPE STEP SEPTIC TANK S_ pIV W/ DIVERTER IN STEP TO NEW & EXISTING `� /o ABSORPTION FIELDS. 1007 S' FCO \ �43 PB per' 1.25" VERIFY EXISTING FCO Q3 T �y PVC OR INSTALL DCO $ }} BEFORE TANK. FENCE. y EXISTING 4BR *NOTE: ELEVATIONS WERE TAKEN & DEPENDING \ RESIDENCE ON RUN THROUGH THE EXISTING FIELD & TO THE PROPOSED ABSORPTION FIELDS GRAVITY FLOW MAYWORK TO THE IF THE EXISTING TNKSIN GRITY IS FOUINDFIELDS. IN THSCBLOCK 6, LOT 3 SOUND, II9-�I- 3 SPUTTERS WILL BE ADDED (1 FOR THE MAIN FLOWLINE & 1 OTHER EACH TO SERVE PAIRED FIELDS) APPORX. ALONG WITH TYPICAL CLEAN OUTS ATE ALL FIELD ENDS. WA.TEA� E. IN, PRIOR TO THE TABLELANDS BLOCK 6, LOT 3 PREPARED FOR: 23005 WHISPERING BIRCH DRIVE ANCHORAGE, AK 99567 CHUGIAK, AK 99567 FIRST WATER CONSULTING 13030 SUES WAY ANCHORAGE, AK 99516 907-350-9566 FirstWaterAK©gmail.com SUPPORTISERVICES: �.i►�.� OF AZT c * 9 DATE: 08/09/24 is Huffman ,W loo SURVEY: GASTALDI , CE 128991 DRAWN: FWCS ,Nb 08/09 /244�.y*t' A/ SCALE: 1" = 30' sslo ,i PAGE: 2 OF 2 \ a First Water C O N S U L T I N G 13030 Sues Way - Anchorage, Alaska 99516 Tel.907-350-9566 firstwaterAKggmail.com SOILS LOG -PERCOLATION TEST LEGAL DESCRIPTION: THE TABLELANDS 136 1_3 DEPTH FEET OG SOILS ORG/OL-RED 1 TO 2.5' NOT SUITABLE 2 3 GM/sm 4 5 6 7 8 9 10 11 12 13 14 15 BOH 16 17 18 19 20 Cc TH .. .., .....�.�... ' Curtis Huffman CE 128991 .• �`v4I+' � 0$/,09`24P��C,�c��,.� �� pROFESSIQU#1 PERFORMED FOR: MATTHEW & HEATHER EDGE TESTHOLE # 24-1 DATE PERFORMED: 8/2/24 GROUNDWATER ENCOUNTERED: SEEPS IF YES, AT WHAT DEPTH: I V DEPTH TO WATER AT MONITORING: 10' DATE: 08/09/2024 SEE SITE PLAN FOR SLOPE & LOCATION COMMENTS: VERIFY GROUNDWATER MT AT TIME OF CONSTRUCTION Reading Date Gross Time Net Time Depth to Water Net Drop 8/8/24 30 min 6" 1" 30 min 6" 15/16" 30 min 6" 15/16" PERCOLATION RATE 32 (MIN / INCH) TEST RUN BEWTWEEN 3 & 4 FT PERC HOLE DIAMETER 6" PRE-SOAKED PRIOR TO TEST & ALL READINGS TO THE 1 / 16Tx PERFORMED BY: FWCS / FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 8/9/2024 4 First Water CONSULTING 13030 Sues Way - Anchorage, Alaska 99516 Tel. 907-350-9566 firstwaterAK a,gmail.com SOILS LOG -PERCOLATION TEST LEGAL DESCRIPTION: THE TABLELANDS 136 L3 DEPTH FEET OG SOILS ORG/OL-RED 1 TO 2.5' NOT SUITABLE 2 3 GM/sm 4 5 6 7 8 9 10 11 12 13 BOH 14 15 16 17 18 19 20 Of Al�tl TH ... ......�... / ' Curtis Huffman 8991 PERFORMED FOR: MATTHEW & HEATHER EDGE TESTHOLE # 24-2 DATE PERFORMED: 8/2/24 GROUNDWATER ENCOUNTERED: WEEPS IF YES, AT WHAT DEPTH: 10' DEPTH TO WATER AT MONITORING: 10' DATE: 08/09/2024 SEE SITE PLAN FOR SLOPE & LOCATION COMMENTS: VERIFY GROUNDWATER MT AT TIME OF CONSTRUCTION Reading Date Gross Time Net Time Depth to Water Net Drop 8/8/24 30 min 6" 11/16" 30 min 6" 12/16" 30 min 6" 11/16" PERCOLATION RATE 44 (MIN / INCH) TEST RUN BEWTWEEN 3 & 4 FT PERC HOLE DIAMETER 6" PRE-SOAKED PRIOR TO TEST & ALL READINGS TO THE 1/16Tx PERFORMED BY: FWCS / FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 8/9/2024 Municipality of Anchorage Page 1 of Development Services Department On-S~te Water and Wastewater Program 4700 South Bragaw Street P.O, Box 196650 Anchorage, AK 99519-6650 www.d.anchorage,ak,us (907) 343*7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW040302 PID Number: 051.801-26 ~'"° Wastewater System: New Spinell Homes 1900 W. Northern Li,qhts, Ste. 200 Anch., AK 99517 ABSORPTION FIELD ~ .~.. ~ a,~.~.. 5' Wide Trench 344-5678 Four {4) LEGAL DESCRIPTION .45 c~.~ 4 6 3 The Tablelands 2 n. 2 ~,. 1-3 ~,. 190 ~,. Well: AWWU Water System 5 ~. 2I >10 F, ~, 1,357 ~ , ASTM 3034 PVC ~, ~isano's Dirtworks~__24-25/2004 '": ~ I~"'" s~''' ~,. Ic'~ ~ '¢"~ r'~'~ ., TANK SEPARATION DISTANCES Septic Tank Field Station Tank Sewer LineAnchorage Tank 1,250 w. >200' >200' NIA NIA >25' Steel Two (2) .s~""w"u.>100'> 5'>100'2, N/AN/A N/ANiA ~V/ ~,. LIFTc~,STATION..~,..,.,,,. - NONE ON LOT F__.~.>5,>IO, NIANiA/~'~...~.'~...,"~.o~.-., I~ c~-~. ~,,.None Noted ~., ~.. ~,..,~ "'~'~: BENCH MARK z" u~rect Hury insulation Over ADsorption Trenches. ~,~.~ ~. Finished Floor. -L~t L!, ' nd~f-Abserptien .,~.. ~.,~. Trenches. - ' ' ¢': 1oo.o F', ;.' '- ' Engineer's Stamp Inspections performed by: T K mbrou,qh ~ v~'. ' Dates: 1' 8125104 ,, ~ 49th ~ ~. 2~ 8125104 ---'. ........... "-' '. Department of Health .and Human Services approval '°°,~.~. No. cc-,,s, ,_ -,,' Permit No.: SW040302 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Page 3 of 3 PID No. 051-801-26 / / / Ntemote THE C¢ TABLELANDS SUBDIVISION LOT 3, BLOCK 6 40,017 S.F. PLAN Four B Home / / u¢ / .eQ~ ,- \\\\ // AS-BUILT '.. SCALE t' = 40' Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit No.: SW040302 Page 3 of 3 PID No. 0514~01-26 .-93.92 //--~° EPS THROUGH01 Ol.~):~ 94.06 Dr'alnFle[d Rock ,~8.64 ,3.50 . , 88.64 93.t4 INSULATION 93,~3 (~eoi:ex~clle Fe b~'lc I}r aln{"letd Rock 88.60 PROFILE AS-BUILT Scale: 1" - 20' INSULATION ~~90,88 ~,,. ~ ~ ~ ~'"--"-'"'" ~'~%~7~ MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Jul 28, 2004 Expiration Date: Jul 28, 2005 Permit Number: SW040392 Parcel ID: 051-801-26 Legal Description: [THE TABLELANDS SUBDIVISION BLOCK 6 LOT3' Design Engineer: 0014 Anderson Engineering Site Address: 23005 WHISPERING BIRCH DRIVE Owner Name: SPINELL HOMES, INC Lot Size: 40017 SQ. FT. Owner Address: 23005 WHISPERING BIRCH DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 EAGLE RIVER, AK 99577- This permit is for the construction of: [] DisposalField [] SepticTank [] Holding Tank [] Privy Private Well [] Water Storage Ail construction must be in accordance with: 1. The attached approved design. 2. A~I requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and dosed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By:.- Issued By:. Date: "7- Z..~, ~ Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Permit Number SW Property owner(s) Splnell Homes, Inc. ~a, iling address (1) t9{~ Northern Lights Blvd., Suite 201 Anchorage, AK 99517 ~l~address(2~,.~5'~.~p, yu~-- ('~1¥¢~ [~. m ZipCode Legal description (Lot, Block & Sub'd.) Lot 3, Block 6, Tablelands Subdivlslon Legal description (Section, Township & Range) Lot Size 40,01'/ Acres/Sq. Ft. Number of Bedrooms Fourl4) Day phone 344-5678 THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool [] Well Only [] [] Water Storage [] [] Jac[r'r/i [] [] Water Softening Unit [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number. (Rev. 1 ?JO0) Waiver Fees: Date of Payment: Receipt Number. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) July 23, 2004 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Lot 3, Block 6, Tablelands Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 3, Block 6, Tablelands Subdivision intends to construct a new four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is served by a community water system and no conflicts exist with adjacent septic systems or wells. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The water service line is also shown. The current drainage pattern along with spot elevations are identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. A test hole recently placed on the lot indicated silty sand and gravel in the area of the absorption trench. The accepting soils were tested and found to have a percolation rate of 30 to 60 minutes per inch. Seepage was noted at 13' below the surface with water accumulation at that level. During the monitoring period, however, the groundwater level was found at 9'. Our design includes the placement of a new 1,250- gallon septic tank along with 2 - 94' long by 5' wide by 2' effective depth absorption trenches to collect and treat the sewage generated in the house. The bottom of the trenches will be 4' below the surface to allow a separation of 5' from the current groundwater level. A flow splitter valve will be placed to assure even flow to each trench. The distribution pipe will be 2' below the surface. A minimum of 3' of cover will be placed atop the trenches and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at shallow grades from north to south as shown Lot 3, Block 6, Tablelands July 23, 2004 Page Two on the Site Plan. The absorption trench will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: t= The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 2004-25 THE TABLELANDS SUBDIVISION LOT 3, BLOCK 6 ~ ~ .o.o~7 s.F. ~22,~ 94' Lm~ Effective Depth ~%oom Home m. ~'m. '~ .~ SiTE PLAN SCALE t' = 40' · LOT 3, BLOCK 6, TABLELANDS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House 5' Wide Trench System Parc. Rate: 30-60 Min.llnch 1,250 Gallon Septic Tank Application Rate: .45 GPDISF 2' Dreinfield Rock 4 Bedrooms X 150 GPD/.45 GPD/SF (Application Rate) = 1,333.3 SF Absorption Area 1,333.3 SFI5 SF * .7 (Red. Factor) = 186.7 LF Trench Length THEREFORE: Construct 2 - 94' Long x 5' Wide x 2' Effective Depth Absorption Trenches. Flow Line Elevation in Trench to be 2' Below Original Ground Surface. Total Depth to be 4' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Provide 2" of Insulation and 2' of Cover if Necessary. Place Flow Splitter Valve to Assure Even Flow to Each Trench. # Natural Backfill Geotextile --Fabdc 4"PeEo~ted --PVC(Holes[~vn) -- Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION NOTE: Grade Area Over Trench to D~in A~y. ~/ Minimum 6' Separation From B~k. Minimum 4' ~epamtion From G~un~ter. Minimum 10 Separation From Water Se~s in ~e Ama. Minimum 100' Sepa~fion From Su~ Water or S~ams~~, ~-~ [VlUNIClPALITY OF ANCHORAGE DEVELOPHENT SERVICES DEPARTHENT /~700 S~)UTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST ] DEPTI I 1 2 3 4 5 6 7-- 8 9 LEGAL DESCRIPTION; LOT 3~ BLOCK 6t TABLELANDS S/D PERFORMED FOR: SPINELL HOMES DATE: 7/13/Z00~, PROJECT No · MOZ,51 T.L. KIMBROUGH PARCEL ID~' TECHNICIAN: I TEST.OLE I I OB DRY REDDISH BROWN SILTY- SANDY-GRAVELS GRAY SILTY-SANDS W/GRAVELS SOME COBBLES TO 10' HEDIUM COMPACTION GM Type of Test: [] Percolation SITI~ PLAN CURB KEY SLOPE 20 COMMENTS: WATER SEEPAGE BOH DATE READ NO GR, OSS T H. EI.NET T,M.E DwS~TT~ NET DRO. F I [HINUTES)I[HINUTES)I (iNCHES) J (INCHES) 7/15/0.C, TEST HOLE PRESOAKED PRIOR TO TESTING: I 8:15 12.0" 2 8:45 30 11.125" 0.875' : 30 I 0.75" I { I 6 945 30 11.25" 0.75" I I WAS GROUND WATER ENCOUNTERED?, YES IF YES (~ WIIAT DEPTH? DEPTI-[ OF WATER AFTER MONITORING: 9.3' DATE OF MONITORING: NO IHPERHEABLE LAYERS ENCOUNTEI~ED. TEST HOLE PRE SOAKED PI~IOR TO TEST. I PERCOLATION RATE; 40 ~IN~CB) PERC. tlOLE DIA, 6 0NCllES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. 712210l, TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICItAEL E. ANDERSON CERTIFY THAT TtlIS WAS PERFORMED 1N ACCORDANCE WITtl ALL STATE AND MUNIClPLE GUIDELINES IN EFFECT ON THIS DATE: 7/2~/200/. DEFI'H (fceB 1 2 3 4-- 5-- 6 7 8 9 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT /..700 S~)UTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG- PERCOLATION TEST I LEGAL DESCRIPTION; LOT 3~ BLOCK 6r TABLELANDS S/D PERFORMED FOR: SPINFLL HOMES DATE: 7/13/Z00/-, PROJECT No' MO/.,SI T.L. KIMBROUGH Type of Test: [] Percolation PARCEL ID#' TECHNICIAN: I TEST HOLE#2 I OB DRY REDDISH BROWN SILTY- SANDY-GRAVELS GRAY SILTY-SANDS W/GRAVELS SOME COBBLES TO 10" MEDIUM COMPACTION GEl SLOPE SITE PI. AN CURB KEY 20 COMMENTS: WATER SEEPAGE BOH DATE 7/510t, READING 0% GROSS TIMEINET T~MEIDEPTH OF NET DROP WATER (INCHES) (MINUTES) I (MINUTES) J (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 1 8:45 11.0" 2 9:15 30 10.375" 0.625" 12.0" 3 4 5 9:15 9:45 30 11.5" 12.0" 9:45 PERCOLATION RATE; 60 O~[NaNCIO PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN:4.5 FT. and 5.$ FT. WAS GROUND WATER ENCOUNTERED?. YES IF YES ~ WHAT DEPTH? 13' DEPTH OF WATER AFTER MONITORING: 9.0' DATE OF MONITORING: 7/Z2/0& NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECIINICAL SERVICE. I, MICtlAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 7/Z&/200I, ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 3, BLOCK 6, TABLELANDS SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250-gallon septic tank at the location shown on the Site Plan. Work also includes the construction of 2 new 94' long X 5' wide X 2' effective depth absorption trenches at the location also shown on the Site Plan. The distribution line in the trenches will be placed at 2' below the existing ground surface. Total depth of the trench will be 4' below the existing ground surface. A flow splitter valve must be placed to assure even flow to each trench. A separation distance of 10' from any water service and 100' between the septic tank and absorption trench and any surface water must also be maintained. A minimum of 3' of fill is required over the absorption trenches and 4' over the septic tank. In lieu of the required fill 2" of insulation and 2' of fill may be placed. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive pdor approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250-gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lo[ 3, Block 6, Tablelands July 23, 2004 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cteanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. o Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. o A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. d- r— C) O7 a) 0') ti r- 0 0 m G) c� 0 U a) a ct3 a) C,6CO . E Q o a) cn a 00 (i3 O Q Q Q U) U) a) 0 O a) m U 'v= a) U LO N 0 N O M ai m D C O .Q. x W 0 0 O CO N 1 O 00 1 LO O a� U (0 F- J J m U) 0 Q J w J m H w F- c O a U N a� a) J ti LO G) 0) Q ca U m Z w a_ U) LO O O cy") N In m a M m U) k w w U w F- C� G w a) c 0 Q O L Q - c 7 U 0 a) O Q Q- M M a) U) N c O a� x Al d- 0 O N m O r a) c� a� co U a) U ca C T 0 M. L) 1 O ^c ^ O N O U) O E 'a O C -_ ~ p N cn O U ~ L d cc c O Q _L _ EU ..r ,O m) Q E C d N O O UE 3 m a +, 'vi N > O C M CL O p 'a C Ea7 E O L o Q. O. a N 0cC r N >, CO v = C m v 0 N R A O L d CO 1 O OO a� v c M E 0. O aa) p > o N C O 0 CLN m L O a N cj N Eo ca rqo cc O t d Q t C O Ln 0 Q9 (n > > O Q U LL a) M a) a u) Z Q NT r - C) CY) CD 0i I? I? O O C)') 0') > v) CL C) 0 ❑ O A.- cQ U Q Q Q O Q. U) W _O UP c 0 O 4 - co U ai A T- dw Al a� a) LL. M �i J v J C: a) 613- 1E IL m � LLL *k O O c O U 0 U U_ r 0 U) N 4) � O >_ 0 COU >, N a E]v Q � �_ L 0 �' I• O E C O _cm a) N Q U O E U cn o M N N C O n0 0 _0) M> E cn ® Q. a) U)�' L O U U ca to N� ❑ ElO U .c 0 a) ~ + cnO > CY a) Vi ~ ❑ 0 7 5 00 a o N w N ❑ _0_ a) ❑ N a > Wo °� ® ❑ U O Q. m (Da) o U J EIL ca m 0 = y+ L L El Q O V > ; a� /Q'/^� a��e CL a O U) 0 ��-J «� E o El ❑ ® Q ® E 'a) W J � �' El y N d H O LU W ❑0 W N R LU H ~Q "+ Q 1 aa) Z O _o m cn a '0 W LL O LL O c a a) � a� m I_- W W O o >, Wc m (D 'O C. L O F- in Q Q Q > N M X W m O a� a) LL. M �i J v J C: a) 613- 1E IL m � LLL *k O O c O U 0 U COSA Checklist.docx COSA Checklist Legal Description: THE TABLELANDS BLOCK 6, LOT 3 Parcel ID: 051-801-26 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA - PUBLIC &/OR CLASS “A” WATER Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume NONE gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank NA Date of pumping NEW – HDPE STEP Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station NEW years Lift station material HDPE STEP TANK Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) NA - NEW ALL standpipes present per record drawing Total measured depth from grade 5.29 ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date NA - NEW Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY – NOT TESTED Effective depth (per record drawings) 18 in Effective depth used 0 in Effective depth remaining 18 in Comments/Deficiencies: COSA Checklist.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) - NA Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No *2 ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS *MOA issued Waiver #WR050034 – 2004 field. G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 10/07/2024 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 10/07/24 s / tK t 0 0 LOT 4 BLOCK 6 LOT 3 BLOCK 6 _ o w 7A,, F 36.6' 9J 10, 4' LOT 2 BLOCK 6 OHO, ol \ / FH 74.5' / O / v ASPLS MORTGAGE LOCATION SURVEY NOTES: NO TITLE REPORT WAS PERFORMED FOR THIS SURVEY, EASEMENTS SHOWN PER THE RECORD PLAT. THERE MAY BE ADDITIONAL EASEMENTS NOT SHOWN HEREON. THIS MORTGAGE LOCATION SURVEY HAS BEEN PREPARED IN ACCORDANCE WITH ASPLS MORTGAGE LOCATION SURVEY STANDARDS. IT IS A REPRESENTATION OF THE CONDITIONS THAT WERE FOUND AT THE TIME OF THE SURVEY. THIS SURVEY DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THAT A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. THE INFORMATION CONTAINED IN THIS DRAWING SHALL NOT BE USED TO ESTABLISH ANY FENCE, STRUCTURE, OR OTHER IMPROVEMENTS. UNLESS GROSS NEGLIGENCE IS DISCOVERED, THE LIABILITY EXTENT OF THE PREPARER SHALL BE LIMITED TO THE AMOUNT OF FEES COLLECTED FOR SERVICES IN PREPARATION OF THIS PRODUCT. LEGEND O RECORD DATA PER PLAT #2004-25 O FOUND 5/8" REBAR, YELLOW PLASTIC CAP EDGE OF ASPHALT FENCE � H FIRE HYDRANT �`" WATER VALVE SEPTIC PIPE H SEPTIC TANK LID 9 UTILITY PEDESTAL n DECK 0' 30' 60' SCALE: V= 30 FEET (11"x17") �_" F. A�gsl j *•••49TH ... *1 J ••Ryan G. Johnson; r�+,•.No. 192159 ,•� 10/4/202.4. AS -BUILT OF: LOT 35 BLOCK 6 THE TABLELANDS SUBDIVISION PLAT #2004-25 ADDRESS: 23005 WHISPERING BIRCH DR, CHUGIAK, AK LOCATED IN: ANCHORAGE RECORDING DISTRICT TIMBERLINE SURVEYING AND MAPPING MOA GRID: NW 1559 17035 BARONOFF AVE FILE NO.: 24.191 EAGLE RIVER, AK 99577 SCALE: 1" = 30 FEET 907-242-5320 DATE: 10/4/2024 ryan@timberlinealaska.com SHEET: 1 of 1 �o �o LOT 4 BLOCK 6 LOT 3 BLOCK 6 _ o w 7A,, F 36.6' 9J 10, 4' LOT 2 BLOCK 6 OHO, ol \ / FH 74.5' / O / v ASPLS MORTGAGE LOCATION SURVEY NOTES: NO TITLE REPORT WAS PERFORMED FOR THIS SURVEY, EASEMENTS SHOWN PER THE RECORD PLAT. THERE MAY BE ADDITIONAL EASEMENTS NOT SHOWN HEREON. THIS MORTGAGE LOCATION SURVEY HAS BEEN PREPARED IN ACCORDANCE WITH ASPLS MORTGAGE LOCATION SURVEY STANDARDS. IT IS A REPRESENTATION OF THE CONDITIONS THAT WERE FOUND AT THE TIME OF THE SURVEY. THIS SURVEY DOES NOT CONSTITUTE A BOUNDARY SURVEY AND IS SUBJECT TO ANY INACCURACIES THAT A SUBSEQUENT BOUNDARY SURVEY MAY DISCLOSE. THE INFORMATION CONTAINED IN THIS DRAWING SHALL NOT BE USED TO ESTABLISH ANY FENCE, STRUCTURE, OR OTHER IMPROVEMENTS. UNLESS GROSS NEGLIGENCE IS DISCOVERED, THE LIABILITY EXTENT OF THE PREPARER SHALL BE LIMITED TO THE AMOUNT OF FEES COLLECTED FOR SERVICES IN PREPARATION OF THIS PRODUCT. LEGEND O RECORD DATA PER PLAT #2004-25 O FOUND 5/8" REBAR, YELLOW PLASTIC CAP EDGE OF ASPHALT FENCE � H FIRE HYDRANT �`" WATER VALVE SEPTIC PIPE H SEPTIC TANK LID 9 UTILITY PEDESTAL n DECK 0' 30' 60' SCALE: V= 30 FEET (11"x17") �_" F. A�gsl j *•••49TH ... *1 J ••Ryan G. Johnson; r�+,•.No. 192159 ,•� 10/4/202.4. AS -BUILT OF: LOT 35 BLOCK 6 THE TABLELANDS SUBDIVISION PLAT #2004-25 ADDRESS: 23005 WHISPERING BIRCH DR, CHUGIAK, AK LOCATED IN: ANCHORAGE RECORDING DISTRICT TIMBERLINE SURVEYING AND MAPPING MOA GRID: NW 1559 17035 BARONOFF AVE FILE NO.: 24.191 EAGLE RIVER, AK 99577 SCALE: 1" = 30 FEET 907-242-5320 DATE: 10/4/2024 ryan@timberlinealaska.com SHEET: 1 of 1 Lot 3, Block 6, Tablelands July 23, 2004 Page 3 of 3 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). Septic tank inlets and outlets shall be tiffed with watertight couplings (Caulder, Femco, or equal). A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain reck layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certitied as-built of the completed system. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DVVELLING Parcel I.D. 051-801-26 GENERAL INFORMATION Complete legal description Location (site address) Expiration Date: / 0 - ~ /-'/-J~-- THE TABLELANDS BLOCK 6, LOT 3 23005 WHISPERING BIRCH DRIVE, CHUGIAK, AK 99567 Current Property owner(s) PAUL & CATHERINE GARDNER Day phone Mailing address 23005 WHISPERING BIRCH DRIVE, CHUGIAK, AK 99567 LendingagenCY ......... Day phone Mailing addres~ - Real Estate Agent RYAN TOLLEFSEN Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: z[ TYPE, OF WATER SUPPLY: IndividUal Well [] IndividUal Water Storage [] Community Class __ Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding Tank Community On-site Public Sewer The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3792 Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 10/19/2011 Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctUate dudng the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these vadous and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies exist. DSD SIGNATURE j/ Approved for Disapproved. bedrooms. Conditional approval for bedrooms, with the following stipulations: ATERAND e : 'ASTEWATER " Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: TABLELANDS BLOCK 6, LOT 3 Parcel ID: 051-801-26 A. WELL DATA Well type PUBLIC if A, B, or C provide PWSID # __ Well Log (Y/N) Date completed Total depth ff. Sanitary seal (Y/N) Cased to ft. FROM WELL LOG Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform colonies/100mL Nitrate Arsenic: __mg/I Date of sample: B. SEPTIC/HOLDING TANK DATA g.p.m. mg/L Collected by: Wires propedy protected (Y/N) Casing height (above ground) in. AT INSPECTION g.p.m. Tank Type/Material Septic/Steel Date installed 8/25/2004 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) 3( Foundation cleanout (Y/N) 3( Depression over tank (Y/N) N__ High water alarm (Y/N) N Date of pumping 10/14/203.3. Pumper J-Rs C. ABSoRP~o~'FIELD DATA' Date installed 8/25/20~ Soil rating (g.p.dY~ or ft2/bdrm) 0.45 System type Shal]ew Trench Length (2x95') 190 f. Width _5 f. Gravel below pipe 2__ff. Total depth 5.5 /5.4 ft. (Measured 10/18/11) Eft. absorption area 3.357 ft2 Monitoring tube Y Depression over field N__ Date of adequacy test 10/18/2013. Results (Pass/Fail) Pass For 4 bedrooms Fluid depth in absorption field before test 0 / 0 in. Water added 640 gal. New depth 4.2 / 0 in. Elapsed Time: 200 min. Final fluid depth 0/Oin. Absorption rate >= 600+ g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN & type) _If yes, give date __ LIFT STATION Date installed "Pump on" level at Datum in. E. SEPARATION DISTANCES Size in gallons ~Pump off' level at __ Cycles tested in. Manhole/Access (Y/N) High water alarm level at in. Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer/septic service line Animal containment areas On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank Manure/animal excrete storage areas Building foundation 5'+ Water main 10'+ Wells on adjacent lots 200'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Property line 5'+ Water service line ~0'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line ~ ~ ~ Building foundation 10'+ Water Service line 10'+ Surface water 100'+ Curtain drain 50'+ (None Known) F. COMMENTS Vacant systcra presoaked with 2000 gallons prior to testing. Absorption field 5'+ Surface water 100'+ Water main 10'+ Driveway, parking/vehicle storage 10'+ Wells on adjacent lots 200'+ (Rev. 11/05) ENGINEER'S CERTIFICATION . ~~l~A te~e~om~s;~atu~r~Ugha~ :;s~to~:r:n'dg} .,.~~ ' g iclelines in effect on this date. '.:~~_~. Engineer's Printed Name KENNETH M. DU}IUS · Date 10/19/2011 ,..~-":')". .... ~".~'. COSA Fee $490.00 Waiver Fee $ DateofPayment ! 0 [ ~ ~ l ~ \ ('~ Pt('. ~l ~{'l'-cc DateofPayment Receipt Number ~)~-~Sq~.- ~ Receipt Number Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.orglonsite (9O7) 343-79O4 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. ,, 051-801-26 1. GENERAL INFORMATION Complete legal description COSA # Expiration Date: Lot 3. Biotic 6, The Tablelands Subdivisle~ Location (site address) . 23005 W~lspedng Bircfl Drive Current Property owner(s) .~mn~e w. and Debra S. Luke Day phone. Mailing address 23005 W~sperlng B~rch Drive Chugfak, AK 99567 Lending agency Mailing address Dayphone Real Estate Agent ' Todd McC~mack Mailing Address Pn~enaal Ja~ White/Vista Real Estate Unless othonvlse requested, COSA w#l be held by DSD for pickup. NUMBER OF BEDROOMS: Four (4) Day phone .762-3169 'tYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System 'i'YPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding Tank F1~ Community On-site Public Sewer ~ 'l'he Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered In the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except behveen spouses) for properties sewed by e single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties sewed by a private or Class C well and may be reissued with new wa!er sample results. (Certif'~ates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properEes sewed by Class A or S wells or a public water system. The Municipality of Anchorage Is not responsible for errors or emissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As cedified by my seal affixed hereto and as of the validation date shown below, I vedfy that my Investigation, based on procedures outlined In the Certiticate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastowatar disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastawater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm, .~ders~ Engineering Address P.O. Box 240773 ~chyerage, AK 99524 Engineer's Printed Name Michael E. Ntdersoo. P.E. 6. DSD SIGNATURE Approved for L/L. Disapproved. Conditional approval for bedrooms. Phone 522-Tr/3 Date. ugrzoos bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory ON-Sri'E '. ~ :- WASTEWATER : E Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: Municipality of Anchorage Development Services Department Building 6afaty Olvlsldn On-~ite Water & W~stewater Program 4700 8ragaw Street P.O. B~ 1~50 Anc~mage, A~ www. munLor~on~l~ CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKUST L~gsI D~c~on: t~ ~. BM ~ 1~ T~lm~ 8ubdh~lan A. WELL DATA w~ type D~e completed T~t~l depth. It. IfA, B. or C provide PWSID # Sanltaw seal (Y/N) Ceaad to FROM WELL LOG g.p.m. Dato of teat Static water level wen pflxluctJofl 8. 5EPTICiHOLOING TANK DATA Tank Typenaate~m, *s,,f,a=~. Date of ~m~pld:, Tank size ~Aso gal. Number of Compa~ments. Two Foundation cleanout (Y/N), Y Depreaslon over tank (y/N), Date of PumpJrlg ~.tYear bt 8era:e Pumper.. C. ABSORPTION FIELD DATA Total depth ,S-~, It. Parcel ID. ,~o1-~ We, Log (Y/N) W~rea propedy pmtectad (Y~q) Casing height (above ground) AT INSPECTION lt. g.p.m. Date installed 8/2Moo4 Cldallout~ (Y/N) Y High water atann (Y/N) N 6ollrating (g.p.d.A~orfl~fodrm) .45GPD/SF Syatemtype s'WMaTmach V~ $ fl:. Gravel below pipe 2 Eft. et~orpUon ama ~ ~ Monitoring tube. ¥ Deprmmldn over field N Date of adequacy test Net Roqulrm Results (Peas/Fag) For ... badmoms Fluid depth in 8bso~ field before test in. Water added gsI. New depth Elapsed Time:. min. Flflat fluid depth ir,. Abeo~ ruto >- Any reJMflatJon Imatmeflt (past 12 mo,) (Y/N & type), If yea, give dato ,, iff. g.p.d. LIFT 8'rATION Date inatalled. Size in galion~ 'Pump on' level at in. 'Pump orr level at in. E. SEPARATION DISTANCES SEPARATION DISTANCES FROM ~ ON LOT TO: Septic tenkaifl etafin on lot A~oq~on filcl on lot Public sewer main Sewer ~ ~en~ce #ne Animal containment areas High water e~rm invel at Meetl Ilalm & cb~ mqumllent~? On adjacent lots On adjacent k~ Public ~ewer manhole/ctearmut Holding lank Manure/animal excrete ~torago areas SEPARATION DISTANCES FROM SEPTICA'IOLDING TANK ON LOT TO: Property line ~ Water sen4ce line >to. N~somflcm field Surface water, >1OD. Building fou~la~n Water main Wells on adjacent lots >200' SEPARATION DISTANCE FROM ABSOFLOTION FIELD ON LOT TO: Propedy line 2-'. BuikiinO foundation >l~r Water main Water Sewice line >1o' Surface water >10o' Dthmway, pammg/~hlcle Cu~ain drain Nme Nmad Wells on adjacent lots )20o' COMMENTS: sm Lo~ Ulne W~. O. ENGINEER'S CER'nFICATION I certify that I have determined thnx~gh field ~ and mv/ew ~ Mon/c/pa/ monn/s thai the above systems am in conformance with MOA COSA guidelines in effect on this date. Engineers PUnted Name Mlmae; E. C~)~ Fee $. Date of Payment Receipt Nun~er (Ray. Waiver Fee $ Date of Payment Receipt Number THE ! ! ! ! ! ! ! ! ! / / / / 2004-25 TABLELANDS SUBDIVISION LOT 5, BLOCK 6 40,017 S.F. 1 "=4-0' SFJ~C ~ EXISTING BUILDING / / AS-BUILT GASTALDI LAND SURVEYING, LLC JEFF A. GASTALDI, 4726 WEST 88TH ANCHORAGE, ALASKA ; PHONE 248-541 GRID DATE .NW i~559 ' JOB 04-;13 ' TLS3 CERTIFY THAT I HAVI~ SURVEYE£ DEPICTED ABOVE AI~D THAT N( ENCROACHMENTS .EXIST EXCEP1 AS INDIC/ IS THE RESPONSIBILITY OF E THE EXISTENCE OF OR RESTRICTIONS ON THE RECORDED S UNDER NO CIRCUMSTANCES St HEREON BE USED FOR CONST ESTABLISHING BOUNDARY OR F · ANCHORAGE RECORDING DIS' NOTE: NO CORNERS SET TE THE rED. HE OWNER TO ANY EASEl ENTS, YHICH DO HOT ~BDIVISION PLAT. IOULD ANY DATA {UCTION OF[ FOR ENCE LINEal. 'RICT, ALASfA S DATE. / Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700. South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH ,AUTHORITY ,APPROVAL FOR ,A SINGLE FAMILY DWELLING Parcel I.D. 051.801.26 1. GENERAL INFORMATION Complete legal description Location (site address or directions) HAA# /") ~ t~ .2-1 '~r Expiration Date: ~ Lot 3, Block 6, The Tablelands Subdivision 23005 Whlspertnq Birch Drive Current Property own. er(s) Spinell Homes, Inc. Day phone 344.5678 Mailing address 1900 Northern Llqhts Blvd. Anchoraqe, AK 99517 Lending agency Mailing address Day phone Real Estate Agent Day phone Mailing Address Un/ess otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four (4) 3. TYPE OFWATER sUPPLY: : Individual Well r-J~ Individual Water Storage [] Community Class ~ Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding tank [] Community On-site [] Public Sewer [] ' The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HM) based only upon the representations given in paragraph 5 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HMs upon request to homeowners. Certificates of Health Authority Approval are valid for ~ days from t~e date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with · valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional ehgineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the HeaIth Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and frown my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Enqtneerfnq Address P.O. Box 240773 Anchoraqe, AK99524 Engineer's Printed Name Michael E. Anderson, P.E. Phone 522.7773 Date 5/23/2005 DSD SIGNATURE I/'''fi'Approved for q bedrooms. Disapproved. Conditional approval for. bedrooms, with the following stipulations: ·. Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory 'X Maintenance Agreements Supplemental Engineer's Report Other Odginal Cedificate Date:~/~~;~.~_. Legal Description: A, WELL DATA Well type Date completed __ Total depth Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.ua (907) 343-79O4 HEALTH AUTHORITY APPROVAL CHECKLIST ~t 3. Block 6. T~p Tablelands Subdivision If A, B, or C provide PWSID # Sanitary seal (Y/N) Cased to ft. FROM WELL LOG ~arcel ID: 05t-801-26 Date of lest Static wat~ level Wall production WATER SAMPLE RESULTS: Coliform ~olonies/100 mi. Date of sample: B. SEPTIC/HOLDING TANK DATA Ce Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION g.p.m. g.p.m. Nitrate mg./L Collected. by: Other bacteria colonies/100 mi. Tank Type/Materiel Tank size t.250 gal. Foundation'deanout (Y/N) Y Date of pumping ABSORP'rlON FIELD DATA Date installed 8/25r2004 Total depth 5-8 ff. Date of adequacy test. SeDtlrJSt~el Number of Compartments Depression over tank (Y/N) Pumper New ConstnJcflon Date installed 8/25/2004 Cleanouts (Y/N) Y High water alarr~ (Y/N) Y Fluid depth in absorption field befor'e test __ in. Water added gal. Elapsed Time: ' min. Final fluid depth in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (YiN & type)' N If yes, give date Soilrating (g.p.d./ft=or~/bdrm).45GPD/SF Systemtype 5'WldeShallowTrench ft. Width 5 ft. Gravel below pipe 2 ff. Eft. absorption area t.357 ft= Monitoring tube Y Depression over field N Results (Pass/Fail) For bedrooms New depth in. g.p.d. D. LIFT STATION Date installed 'Pump on' levet at in. Datum E. SEPARATION DISTANCES Size in gallons 'Pump off" level at __ in. Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot N/A Absorption field on lot N/A Public sewer main N/A Sewer/septic service line N/A Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? On adjacent lots NIA On adjacent lots N/A Public sewer manhole/cleanout Holding tank Property line >5' Water service line Absorption field Surface water >11~ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation Water main Wells on adjacent lots >200' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation >'11~ Surface water >t00' Wells on adjacent lots >~0' Water main >15, Driveway, parking/vehicle storage >5, Property line Water Service line Curtain drain Nons Noted F. COMMENTS ~ See Lot UAe Waiver. Rroeerh' iS ,~mted by AWWU Water $~lem G. ENGINEER'S C~FICA~ON I ~ that I ha~ de~ ~gh ~ld in~s a~ mv~w ~ Mu~ip~ m~s ~at ~ a~ s~ms am in c~e~e ~ MOA H~ gu~eli~s in e~ ~ ~is da~. E~i~'s Pd~ Name Ml~ael E ~dem~. P.~ Da~ ~ 05 V~a"/" L/NE , iver Fee $ Date of Payment Receipt Number /'75' HAA Fee $ ~'7 ~?'''' Date of Payment ~'~ ~. ~'-- 0 ~ Receipt Numbsr [~ ~., THE .,~. ! / / ! ! ! / / / / 2004-25' TABLELANDS SUBDIVISION LOT 3, BLOCK 6 40,017 S.F. / / -40 EXISTING BUILDING / / / / / / / / / / / / / AS- B U I LT HEREBY CERTIFY THAT I HAVE SURVEYEI~ PROPERTY DEPICTED ABOVE AND THAT NO GASTALDI LAND ENCROACHMENTS .EXIST EXCEPT AS ,NDICA SURVEYING, LLC IT IS THE RESPONSIBILITY OF THE OWNER JEFF A. GASTALDI, R.L. DETERMINE THE EXISTENCE OF ANY EASEk 4726 WEST 88TH AVEN I~OVENANTS OR RESTRICTIONS WHICH DO ANCHORAGE, ALASKA 99~ EJ~'~PEAR ON THE RECORDED SUBDIVISION PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY GRID DATE HEREON BE USED FOR CONSTRUCTION OF ESTABLISHING BOUNDARY OR FENCE LINE-~ .NW 1559 2/17/2005 ANCHORAGE RECORDING DISTRICT, ALAS F.B. JOB NO. 04-13 'TLS36 NOTE: NO CORNERS SET THIS DATE. THE rED. TO ENTS, qOT ~LAT. IATA FOR agc, Alaska ,DS 19-('~L~' I * Tclclfl~onc (~)?) 8434 4700 Bragaw Slrcct * Amchomgc, Alaska ~)507 P.O. Ik~x 19C~;,'~0 · Anchor'affc. Alasl~ 9t~,lg-f:~.~! * Tdcphonc (~)7) ~.I~-8~)I · Fax (!~7) Mayor Mark Be§ich w~s-~'.munl.org Building Safcty Dlvlston 5/26/2005 Anderson Engineering P.O. Box 240773 Anchorage, Alaska 99524 Subject: Waiver Request for The Tablelands Subdivision, Block 6, Lot 3 Waiver Request #WR050034 Parcel ID #051-801-26 HAA# HA050217 Dear Mr. Anderson: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 2.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-7904. Sincerely, Julie Makela, P.E. Civil Engineer On-Site Water & Wastewater Program Community, Security, Prosperity Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastcwatct Program 4700 Bragaw Strcct P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorag¢.ak.us (907) 343-7904 Waiver Review Worksheet WF~: WR050034 PIDg: 051-801-26 HAg: HA050217 Permitg: Date Received: 5/24/2005 Legal Description: Th9 Tablelands Subdivision. Block 6. Lot 3 Engineer. t I Applicant: ~$Dtrtell Homes. Inc. Waiver Requested: 2 feet from absorofiofl field to Dro~ertv line Criteria: Geology A. Water Table B. Soil SorptJon C. Permeability D. Water Table Gradient E. Horizontal Separation Points: Total: Waiver Is Granted: ~ Waiver is not Granted: List Conditions or Reasons for above: Rec#: 68278 Amount: $175.00 Date Paid:~ ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522.7773 522-6779 (FAX) May 23, 2005 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Su~e~: Lot 3, Block 6, The Tablelands Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The absorption trenches on the subject lot were constructed within 2' of the southwest lot line to accommodate the construction of the new house and to take advantage of the favorable topography of the lot's surface. The subdivision is served by the Municipal water system so no wells are located in the area. In addition the system is much more than 10' from any septic system on the surrounding lots. The placement of the absorption trenches within 2' of the southwest property line will have no impact on the surrounding lots and will not encroach into areas reserved for septic systems. We therefore request a waiver be issued allowing the trenches to be 2' from the southwest property line. Sincerely, Michael E. Anderson, P.E.