Loading...
HomeMy WebLinkAboutMOUNTAINSIDE VILLAGE #1 BLK 5 LT 7Mountainside Village #1 Block 5 Lot 7 #020-172-41 Municipality of Anchorage Development Services Department Building Safety Division 5 ^ F On -Site Water and Wastewater Program, 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SWO80094 PID Number: 020-172-41 Name: JIM EAVES Wastewater System: ® New ❑ Upgrade Address: 20322 NEW ENGLAND DRIVE EAGLE RIVER AK ABSORPTION FIELD Phone: Number of Bedrooms: ❑ Deep Trench ❑ Shallow Trench ® Bed ❑ Mound ❑ Other: LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: 0.5 GPD/Ft2 0 Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 5 7 MOUNTAINSIDE VILLAGE +0.5 Ft. 0.5 Ft. Township: Range: Section: Fill added above original grade: Gravel Length: 2.0 Ft. 80 Ft. Well: New ❑Upgrade Gravel width: 15 Number of lines: 3 Distance between lines: 5.0 Ft. Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Private 206 Ft. 24 Ft. 1200 Ft2 3034 PVC Driller: Date Drilled: Static Water Level: Installer: Date Installed: Alpine Drilling 8/27/2006 10 Ft. BEEK EXCAVATION 1 5/2812007 Yield: Pump Set at: Casing Height Above Ground: TANK 15 GPM Ft. 2 Ft. SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding ublic/Private Manufacturer: Capacity: From Tank Field Station Tank Sewer Line Anchorage Tank 1250 Gal. Well 170' 167' - - 160 Material: Steel Number of Compartments: 2 Surface Water 100+ 100+ - - LIFT STATION 113' 87' - Size: Manufacturer: Lot Line Gal. Foundation 9.3 20' - - "Pump on" level at: "Pump off' level at: High water alarm at: in. in. in. Curtain 100+ 100+ - Pump Make & Model Electrical Inspections performed by: Drain Remarks: WELL DATA FROM DRILLER'S WELL LOG. Well pump not BENCH MARK Location and Description: installed as of this report. HOUSE Finish Floor Assumed Elevation: 100.0 Ft. Engineer's Stamp Inspections performed by: PANNONE ENG. SVC, LLC Dates: 1St 4/11/2007 "� 6121109 ��������� �• F 2nd •� . �P� •' �?,.''� ...��`.:;9#i# Development Services Department Approval Conditional Approval Date:„•„;;•• 49TH :-f�•/ /�V .... .� • j/ :Steven , ••,Pannone; •a AF1 and approved by: �-1/�•('�iLl Date: 171,2o i % ra,"'d �1�< 'CO+I� O •. C� ; No. CE 8149 :�WReviewed (Rcv. 04/06) `�� �,,,1 -y-•ESS \,, SWNG/TIES CO: A B FC 7.95 T7 34,51 T2 24.01 277' ,DCV 28.7 24.2 DC2 29:6 23.6 MTI 47.8 57.7 MT2 8'6.7 / 1 53.2 I O I Ij O 4h:1v slopes typical for 50' minimum 90.5'j OR PRIMARY FIELD 2.5 -5.0--t 5.0- 2.5 0,5 AS 75.0 GM i59o.o* —6 BR No No groundwater —6+ BOH monitored 8122103. SECTION RESERVE FIELD 2 10.0 12.5 2' Fill, Topsoil & Seed top 6" '2 " R. /. -Filter Fabric %' ovel 6" above pipe ' / 6 r, -b - DistriB on Pipe 4" Grovel below pipe inv NOTE: Reserve Field sized based on the use of on advanced treotement system (Advantex AX20 system and tank.) Z OF k' hk PAMONE ENG SVC, LLC "I Date ?w 0,5 AS 75.0 GM i59o.o* —6 BR No No groundwater —6+ BOH monitored 8122103. SECTION RESERVE FIELD 2 10.0 12.5 2' Fill, Topsoil & Seed top 6" '2 " R. /. -Filter Fabric %' ovel 6" above pipe ' / 6 r, -b - DistriB on Pipe 4" Grovel below pipe inv NOTE: Reserve Field sized based on the use of on advanced treotement system (Advantex AX20 system and tank.) Z OF k' hk PAMONE ENG SVC, LLC "I Date ?w P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE 8/20/09 RECORD DRAWINC Scale O Mountain Side Village SID, Block 5, Lot 7 2 49 TH TH 2" R.I. DI ' stribution Pipe P.J.D. NO o Steven P Mr. James Eaves 4 "0, 3034 PVC PERMIT NO. SW080094 nnone CE 8149 20322 New England Drive DESIGN Ok <�e' Eagle River, AK 99577 S=0.0000 Sheet PR 0 �S� P: - - �C '%' - DETAIL 3 of 5 92.5 92.0 New 1250g Septic Tank MIN. SLOPE 90,5, S=O. 010 0 900' BED— SEE PLANS & SECTION FOR DIMENSIONS PROFILE RE -CORD DRAWING OF k' hk PAMONE ENG SVC, LLC REVISED Date P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE 8/20/09 RECORD DRAWINC Scale (907) 272-8218 FAX (907) 272-8211 Mountain Side Village SID, Block 5, Lot 7 49 TH TH 1:100 P.J.D. NO o Steven P Mr. James Eaves 020-172-4] PERMIT NO. SW080094 nnone CE 8149 20322 New England Drive DESIGN Ok <�e' Eagle River, AK 99577 Sheet PR 0 �S� P: - - �C '%' - DETAIL 3 of 5 FROM : ALPINE DRILLING FAX NO. : 907 345 0202 Oct. 29 2006 11:37PM P1 ALPINE DRILLING & ENTERPRISES Permit Number. #SW060056 Date of Issue: 4-13-06 Parcel Identification Number: 020-172-41 Date Started: 8-27* 06 Date Completed: 8-27-06 is well located at approved permit location? R Yes [:1 No Legal Destription: Mountainside Village #1 Blk 5 Lot 7 Property Owner Name & Address: Jim Eaves 20322 Now England Drive Eagle River, Alaska 99577 Borehole Data; Depth (ft) Method of Drilling Z air rotary El cable too] Soil Type, Thickness & Water Strata From To Casing type: steel fractured bedrock 1 2 Wall Thickness: -250 inches bedrock 2 206 Diameter: 6 inches Depth: 24 feet Liner Type: qjc Diameter: 4 inches Depth- 0 to 50 feet Casing stickup above ground: 2 feet Static water level (from ground level): 10 feet Pumping level: 206 feet after 2 hours pumping 15 gpm Recovery Rate.- 15 gpm Method of Testing: airlift Well Intake Opening Type: Fj Open End ®?pen Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped — feet Grout Type: bentonite g—ranules&chins Volume: 3 Depth: Start 0 feet Stopped 22 feet Pump: Intake Depth feet Pump size _ hp Brand Name Well Disinfected Upon Completion? Z Yes Fj No Method of Disinfection: chlorine tablets Comments: Well was lined from 0' to 50' with pvc 4 with shale packers placed at 50 feet with henonite chips installed from 10'to 50 !below toc.- Well Driller; Alpine Drilling & Enterprises PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property owner or the well driller shall provide a well log to the Development Services Department within 60 days of completion. Development Services Department Building Safety Division *AE On-Site Water & Wastewater Program4700 Elmore RoadP.O. Box 196650Mark Begich Anchorage, AK 99507 Mayor www.muni.oro/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: SW 060056 Parcel Identification Number: 020-172-41 Legal Description Block 5, Lot 7 Mountainside Village #1 Pump Installation Date: 11/5/2012 Pump Intake Depth Below Top of Well Casing: 232 Pump Manufacturer's Name: Grundfos Pump Model: 1580E-15-290 Pump Size 1 1/2 hp Pitless Adapter Burial Depth: NIA feet Pitless Adapter Manufacturer's Name: NIA Pitless Adapter Installer: N/A Well Disinfected Upon Completion? 0 Yes ❑ No Method of Disinfections chlorine tablets Comments: Pump Installer Name: Aarow Pump & Well service, LLC P.O. Box 110496 Anchorage, AK 99511-0496 feet Date of Issue: 411312006 Property Owner Name & Address: Jim Eaves 20322 New England Dr. Eagle River, AK 99577 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water b Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Renewal Date Issued: Jun 24, 2008 Expiration Date: Jun 24, 2009 Permit Number: SWO80094 Parcel ID: 020-172-41 Legal Description: MOUNTAINSIDE VILLAGE #1 SUBDIVISION BLOCK 5 LOT 7 Design Engineer: 0062 PANNONE ENGINEERING SERVI( Site Address: NHN MT MCKINLEY DRIVE Owner Name: JIM EAVES Lot Size: 190546 SO. FT. Owner Address: 20322 NEW ENGLAND DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 EAGLE RIVER, AK 99577 - This permit is for the construction of: ❑ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 1 BAAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. PROVIDE CONFIRMATION SOILS LOGS WITH ASBUILT INSPECTION REPORT. Received By: Issued By: Date: I(/7 -VM Date: g MUNICIPALITY OF ANCHORAGE Building Safety Division :' f DATE: June 24, 2008 DUM TO: Mountain Side Village #1, B5 L7 File FROM: Deb Wockenfuss On -Site Water Wells and Wastewater Program SUBJ: Bed installed on a slope > 10% The new wastewater disposal field does not meet AMC15.65.060.H.3. Slopes do not meet the maximum 10% requirement. The existing system may remain on the excessive slope per the Development Services Department Director, Ron Thompson. If there is evidence of day -lighting, actions are to be taken to remove the threat of surface water contamination. An engineer is to provide a design that addresses the concern and a permit is to be applied for and approved to make the necessary changes. Municipality of Anchorage Development Services Department Building Safety Division water On -Site Wateer and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWERMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. OZ O — I%Z' y 1 'r Fnvt Day phone Property owner(s) I � .,.,�anr+l 17r. £R. zip Code Qg57-7 Mailing address �= t7 '32:2- NNes. / _ — Mt. Mckinnle pr _zip Code C)ClC5 Site address �� � 11 _ Legal description (Sub'd., Block & Lot) i io arl tni 11 Legal description (Township, Range & Section) Lot Size I CIO, h 1-1 Fi Sq. Ft. Number of Bedrooms THIS APPLICATION IS FOR (Z all that apply): Absorption Field Septic Tank Holding Tank Privy Private Well F1 Water Storage R THIS APPLICATION IS AN: Initial Upgrade 0 Renewal R I certify that the above information is correct. I further certify that this application is being made for a Sinale-Family Dwelling and is in apon(dance with applicable Municipal Codes. property owner or authorized agent) Date of Payment: Date of Payment: Receipt Number. I (?S Z2_6 Receipt Number. (Rev. 11105) MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Renewal Date Issued: Jun 19, 2007 Expiration Date: Jun 18, 2008 Permit Number: SW070114 Parcel ID: 020-17241 Legal Description: MOUNTAINSIDE VILLAGE #1 SUBDIVISION BLOCK 5 LOT 7 Design Engineer: 0062 PANNONE ENGINEERING SERVI( Owner Name: JIM EAVES Owner Address: 20322 NEW ENGLAND DRIVE EAGLE RIVER. AK 99577 - Site Address: NHN MT MCKINLEY DRIVE Lot Size: 190546 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑,/ Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. The upper six inches of the mound system must consist of lop soil and the mound must be vegetated sufficiently to prevent erosion. Received By. Issued By. I N, s /, Date: nV - 19' 6' Date: Lei Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcell.D. ooxi-/-1a.y1 Property owner(s) James Eaves Day phone Mailing address 20322 New England Drive, E.R. Zip Code 99577 Site address 17201 Mt Mckinnlev Drive Zip Code 99516 Legal description (Sub'd., Block & Lot) _ Mountain Side Village No 1. Block 5, lot 7 Legal description (Township, Range & Section) Lot Size 190.546 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage Cl Number of Bedrooms 4 THIS APPLICATION IS AN: Initial ❑ Upgrade ❑ Renewal certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Pannone LLC (Signature of property owner or authorized agent) Permit/Rush Fees: "7 L o Waiver Fees: 1.7 i Date of Payment: G -6 - o'7 Date of Payment: Receipt Number: % Z U Receipt Number: / 5.S % �- (Rev. 11/05) Pannone Engineering Services, LLC Consulting Engineers June 6, 2007 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program 4700 S. Bragaw Street P. O. Box 196650 Anchorage, Alaska 99519 Subject: Mountain Side Village SID, Block 5, Lot 7 Septic System Permit Request Ladies and Gentlemen: P.O. Box 102954 ge, Alaska, 99510 )071272-8211 Fax I am writing to request that a permit to install a new septic system be re -issued for this lot and the Stop Work Order be removed. The proposed systems will serve a new four-bedroom house. Currently the lot is being developed. The drain field and septic tank were installed under the original permit SW060056. The septic tank was removed without my knowledge when the contractor needed a place to put overburden from the house excavation (he placed approximately 12 feet of gravel over the septic tank location. This would have compromised the integrity of the septic tank, which is only rated to six feet of burial.) The septic tank shall be re -set under this new permit. Your Department issued a Stop Work order on May 25ih citing the design slopes do not represent the actual conditions of this lot, the new septic system will be to close to slopes in excess of 25%, and the reserve location is not available due to the excess slopes. This letter and the attached revised drawings will address the concerns cited in the Stop Work Order. Comment: The design slopes do not represent the actual conditions of this lot. Response: The original design was developed by Anderson Engineering and showed the slopes at 15%. The actual slopes are closer to 50%. The revised design shows the actual slopes based on MoA Mapping that was conducted in 1997. Comment: The new septic system will be to close to slopes in excess of 25% Response: I performed a survey at the site on May 28"' with the septic Contractor, Mr. Dan Beek. We found that we will be able to meet the grading requirement of 25% for fifty feet on the majority of the field. The north end of the field we will only be able to obtain a separation distance of 35 feet. I request a separation waiver from a slope of 25% or greater from 50 feet to 35 feet. Based on the soils information, granting this waiver will not affect the public health. The soils are relatively fast percolating soils and the effluent will absorb at a slope of 20 to 30 percent off the vertical. Comment: The reserve location is not available due to the excess slopes. Response: The reserve location as Anderson designed it is not available. I proposed a reserve field size based on the use of an advanced wastewater treatment system. Using an Advantex treatment System, the reserve field requires 120 sf. A 15' by 10' can be installed uphill from the original system and below the house. The treatment system would require an auxiliary pump vault to deliver the effluent to the field. Please see the attached design drawings. Design Parameters The surrounding lots are served by private water systems, which are over 100 feet from the proposed soil absorption system. The lot is served by a private water system. 1. Solls. Anderson Engineering investigated the soils in August of 2003. No ground water was monitored in the test holes to a depth of 6 feet below ground level. Bedrock was encountered in the test holes at a depth of six feet. It is my opinion that the overall soils appearance of the soils, an application rate of 5.0 gallons/day/square feet should be used using an Class III advanced treatment system with an auxiliary pump vault. Page 1 of 2 . Page 2 of 2 2. Soil Absorption Field Design. a. Percolation Rate: b. Application Rate: c. Number of Bedrooms: d. Design Flow: e. Min. Absorption Area: £ Total depth: g. Effective Depth: h. Width: i. Minimum Length: j. Design Length: k. Effective Absorption Area: I. Septic Tank Size: 5-15 Min Per Inch 5.0 gpdpsf 4 600 gallons per day 120 sf 0 feet 0.5 feet 10 feet 12 feet 15 feet 150 sf 1,500 gallon STEP Tank W AX20 Treatment Pod 3. Surface Water: There is no surface water within 100 feet of the proposed system. The proposed systems will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: Lot 7 slopes to the southwest at approximately 50 percent in the vicinity of the septic system. The lot is steeper to the west and to the east. The area down hill of the system will be graded to 25% for 35 to 50 feet as shown on the Plans. See above waiver request. The proposed installation will not affect the future development of the surrounding or existing lots. There are no wells or septic systems within 100 feet of the proposed septic location. If you have any questions or concerns, please contact me at 272-8218. Sincerely, Steven R. Pannone, P.E. Owner/Civil Engineer Attachments: C:\Work\Letters\7-5 Mt Side Village.001.doc .. T��� ON�\R` � PANNONE ENG SVC, LLA. REVISED Dote OFq�gSjll P.O. BOX 102954 ANCHORAGE, AK 99510 06/05/07 PHONE (907) 272-8218 FAX (907) 272-8211 St :etoo' ... '...:.. / P.I.D. NO Mountain Side Village SID, Black 5, Lot 7 20-172-4t •eleven k. 'nnor+e'/ Mr. James Eaves CE 8149 PERMIT N0. �'. �/ (114x''•06/13 20.322 New England Drive Sw07xxxx (�DSypu Eagle River, AK 99577 DESIGN rSheet PLAN OF 5 / T2 47.1y � :1 Thi1 - I3 .0 it l j2:1 5 i K\ 2: lLL �\ I 255 .0 ... .. $teven R. Ponnope �j, •_ CE 8149 1 AN REMOVED TO C£. TO E F SED. HOUSE FO CON PANNONE ENG SVC, LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 Mountain Side Village SID, Block 5, Lot 7 Mr. James Eaves 20J22 New England Drive Eagle River, AK 99577 5 ) \ W O O \0\ /1307 � REVISED Dote 6/06/07 Scale 1'-50' P.I.D. NO 20-172-4 PERMIT NO. SW07xxxx DESIGN sheet PLAN 2 OF 5 4h:1y slopes typical for 50' 1.0 rOR MN FIELD AS 15.0— -6+� No groundwater BOH monitored 8122103. SECTION REMFEW 2' Fill, Topsoil & PANNOoNE4ENGRASVC, 9LLC PHONE (907) 272-8218 FAX (907) 272-8211 Seed top 6". Date 06/06/07 C G C REMFEW 2' Fill, Topsoil & PANNOoNE4ENGRASVC, 9LLC PHONE (907) 272-8218 FAX (907) 272-8211 Seed top 6". Date 06/06/07 2" R.I. Filter Fabric ountoin Side Villoge SID, .Block 5, Lot 7 Mr. James Eoves 20322 New England Drive Eagle River, AK 99577 ave, 6" above pipe F--5.0 P.I.D. NO -172-4 Distri on Pipe 4" MIT N0. o7 xel PSle DESIGN DETAIL 3at 5 below pipe Inv. NOTE. • Reserve Field sized based on the use of on advanced treatement system (Advantex AX20 system and took.) h 96 BCD- SCC PLANS t SCCDON FOR &MENSAMS PROFILE ISSUED FOR CONSTRUCTION 6/13/07 � —,SOFA ,q1k /iy. �y��l everi'R: 3d 'ne'j (� CE 8149 ss'•06/13/0,7-- PANNOoNE4ENGRASVC, 9LLC PHONE (907) 272-8218 FAX (907) 272-8211 REVISED Date 06/06/07 Scale 1:100 ountoin Side Villoge SID, .Block 5, Lot 7 Mr. James Eoves 20322 New England Drive Eagle River, AK 99577 P.I.D. NO -172-4 MIT N0. o7 xel PSle DESIGN DETAIL 3at 5 SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN .THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL SYSTEMS. 2. ALL WORK SHALL BE IN ACCORDANCE WITH THE ATTACHED SPECIFICATIONS. 3. SCOPE OF WORK: 4—BEDROOM HOUSE. NEW DRAIN FIELD, 1250g SEPTIC. TANK, RESERVE FIELD: 1500g STEP TANK, 1 EA. ADVANTAX AX20 POD. THE PRIMARY DRAINFIELD AND SEPTIC TANK WAS INSTALLED PERMIT SW060056. THE TANK WAS REMOVED TO PREVENT CRUSHING WHILE MOVING OVERBURDEN. THE TANK SHALL BE RE—INSTALLED UNDER THIS PERMIT REQUEST. 4. GROUNDWATER IS NOT EXPECTED TO BE ENCOUNTERED DURING EXCAVATION. AS EVIDENCED BY THE SOIL TEST HOLE INFORMATION. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 6 FEET BELOW EXISTING GRADE, NOTIFY THE ENGINEER IMMEDIATELY. 5. THE CONTRACTOR SHALL VERIFY DEPTH OF BEDROCK AND INSTALL A SAND LAYER TO ACCOMPLISH A SEPARATION BETWEEN THE BOOTM OF THE FIELD AND BEDROCK OF A MINIMUM OF SIX FEET (6'). 6. GRADE SLOPES TO ACCOMPLISH A FINISH GRADE OF 25% FOR 50 FEET AROUND THE NEW DRAINFIELD AS SHOWN. TOPSOIL 6t SEED FINISH GRADE TO PREVENT EROSION OF SURFACE. IEA ADVANTEx AJ%ILLAPY PASSIVE AIR SL OVER THIS SHEER f BRIDGE DESIGN PARAMETERS RESERVE FIELD: NO. BEDROOM: 4 DESIGN FLOW= 600 gpd TANK SIZE: 1500 gallon PERC. RATE: 5-15 MPI SOIL RATING: .5 gpd/SF AREA ROD: 120 SF SYS. TYPE: BED, 0.5' ED MIN LENGTH: 12 LF 10' WIDE UM. 15LFx10'WIDE, 0.5'ED, 1' TO TOTAL AREA: 150 SF. ADVANTEX DETAILS ABBREVIATIONS CU COPPER DIP DUCTILE IRON PIPE TH TEST HOLE FC FOUNDATION CLEAN—OUT T# TANK CLEAN—OUT NO. C# CLEAN—OUT NO. M(( MONITOR TUBE NO. R.I. 'RIGID INSULATION LEGEND WATER LINE/ WELL RADIUS — $3 — SS — EXIST'G SEPTIC — Is — Is — NEW SEPTIC 0 CHAINLINK FENCE ISSUED FOR CONSTRUCTION 6/13/07 a i �F.�:gS�ll+ wig: q �I .. .. .....'* _Mountain Steven R. Pon. ,I14f•.00E1349 11 ` ` I1�� `V� PANNONE ENGINEERING SVC, LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 REVISED Dote 06 -os -o7 Scole NTS Side pillage SID, Block 5, Lot 7 Mr. James Eaves 20322 New England Drive Eagle River, AK 99577 P.I.D. NO 20-172-4 PERMIT N0. SW07xxxx DESIGN NOTES 5neet 4 or 5 I MO / / rar / / nu / nn / I' ROP S£D 4 -BR / _ H Si t rat I = lao FF 1 2? I role / renQJVGIA/ M's — rrr /I FG=1599. IIn1 25Z SLOP wo RVISIL GRADE / IN TALLE DRA FILL IW —B / F PIKE lNV THIEL 15965 8 8£ ROCI 15416: = 15A0.0 / 6. I' IW I' FG=1586. j/ net - 2: SLOPS / L IAM MA / TO OF SLOPE CATCH C SHOL, LDER rso / Im 101A /IMO r01I0 IONO 11100 11N0 ItW 11N0 11 IJ100 IJ1le n10 IMp rJ1en tJ100 rm / l SECTIOV A A IAM l 100 SSUQ FOR C NSTRUCTI N 6 13 7 Ian e I / SOFA��1 T � PANNONE ENG SVCt LLC LLC REVISED Dote. _ C•.• q5+1�' �p'• :-V P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8118 FAX 6/6/07 Scole �* nt (907) 272-8211 r_50• ,tl� �•• ountoin Side Villoge SID, Block 5, Lot 7 P.I.D. NO 20-172-41 �/ ••blevenR. none j CE 8149 �� I,+4s�i•,', Mr. James Eoves PERMIT N0. 5W07xxzx •06/13 20322 New England Drive .0 a (l^Tp�OfE59(1��� Eagle River, AK 99577 SECTION sneer 5 OF 5 MUNICIPALITY OF ANCHORAGE Development Services Department On -Silo Water 6 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Renewal Permit Number: SW060056 Date Issued: Apr 13, 2006 Expiration Date: Apr 13, 2007 Parcel ID: 020-172-41 Legal Description: MOUNTAINSIDE VILLAGE #1 SUBDIVISION BLOCK 5 LOT 7 Design Engineer: 0014 ANDERSON ENGINEERING Owner Name: JIM EAVES Owner Address: 20322 NEW ENGLAND DRIVE EAGLE RIVER, AK 99577 - Site Address: NHN MT MCKINLEY DRIVE Lot Size: 190546 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit Is for the construction of: ❑.r Disposal Field Q Septic Tank ❑ Holding Tank [:] Privy All construction must be In accordance with: 1. The attached approved design. QQ Private Well 0 Water Storage 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. The upper six Inches of the mound system must consist of top soil and the mound must be vegetated sufficiently to prevent erosion. Received By Date: 443-9 -9 Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEPTIC/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. q/ Property owner(s)- Jim , !—AyVjs Day phone &j�i- �.l Mailing address.. SLO= A604) 6&VQ MAW AW �, E7'� Zip CodeS-7 7 Site address Legal description (Sub'd, Block & Lot) Legal description (Township, Section & Range) Lot Size 1 190, 5 44o Sq. Ft. THIS APPLICATION IS FOR (®all that apply): Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage AIA Zip Code q9SI to Number of Bedrooms 4 THIS APPLICATION IS AN: Initial ❑ Upgrade El Renewal ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. 6 % owner or authorized agent) Permit/Rush Fees: Waiver Fees: Date of Payment: _ 4 I1 1w, Date of Payment: Receipt Number: 6Receipt Number: (Rev. 11105) MUNICIPALITY OF ANCHORAGE Development Services Department Onsite Water b Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number. SWO50064 Date Issued: Apr 04, 2005 Expiration Date: Apr 04, 2006 Parcel ID: 020-172-41 Legal Description: MOUNTAINSIDE VILLAGE #1 SUBDIVISION BLOCK 5 LOT 7 Design Engineer: 0014 Anderson Engineering Owner Name: JIM EAVES Owner Address: NHN MT MCKINLEY DRIVE ANCHORAGE. AK 99516 - Site Address: NHN MT MCKINLEY DRIVE Lot Size: 190546 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑✓ Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. -- - T B. Covered, seated, and heated to prevent freezing. 5. The following special provisions. THE UPPER SIX INCHES OF THE MOUND SYSTEM MUST CONSIST OF TOP SOIL AND THE MOUND MUST BE VEGETATED SUFFICIENTLY TO PREVENT EROSION. Received By. r Date: / tl 15 - Issued By. Date: q14 D Municipality of Anchorage �• Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 620- /32 — 41 Permit Number SW Property owner(s) Jim Eaves Day phone 6945521 Mailing address (1) 20322 New England Drive Eagle River, AK 99577 Mailing address (2) b Od Mt. McKinley Drive Zip Code *tI Legal description (Lot, Block & Sub'd.) Lot 7. Block 5, Mountainside Village Subdivision Legal description (Section, Township & Range) Lot Size 190.546 SF _Acreto Number of Bedrooms Four (4) THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well ® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. a (Signature of property owner or authorized agent) Permit Fees: 166 •0D Date of Payment 5-1—OS' Receipt Number. (Rev. MOO) W Fees: Date of Payment: Receipt Number. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 MEMO DATE: 3/30/2005 TO: Joe Goodall WITH: MoA/OnSite Water and Wastewater FROM: Mike Anderson SUBJECT: Lot 7, Block 5, Mountainside Village Subdivision Well and Septic System Permit Attached are the test hole logs and percolation tests with original signatures for the subject lot. We have also verified the septic tank is a minimum of 5' from the building foundation as shown on the attached Site Plan. We are requesting the test holes to verify the soil conditions for the alternate site be placed during construction to reduce mobilization costs for the backhoe. Groundwater monitoring will be performed during the construction period and test hole data transmitted prior to construction of the new absorption bed. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX March 6, 2005 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 7, Block 5, Mountainside Village Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 7, Block 5, Mountainside Village Subdivision intends to construct. a new four-bedroom home on the property. We are therefore requesting a permit be issued for the construction of a new well and septic system to serve the home. This is a large lot containing nearly 4.4 acres and no conflicts exist between the proposed well and septic system and those on adjacent properties. The Site Plan and backup documentation identify the location and configuration of the proposed well and septic system. Existing drainage arrows and the current drainage pattern are also identified on the Site Plan. The drainage pattern will be maintained after development of the new system is complete. Test holes placed near the location of the new absorption bed and alternate site by The Gamess Engineering Group. Their analysis revealed silty sand and gravel to depths of 6' to 7' underlain by bedrock. The accepting soils were tested and found to have a percolation rate of between 6 and 8 minutes per inch. No groundwater was found during excavation and none was noted during the monitoring period. Our design includes the placement of a new 1,250 -gallon septic tank along with a new 80' long by 15' wide absorption bed to collect and treat the sewage generated in the house. The bottom of the bed will be at the ground surface to provide a minimum of 6' separation to bedrock. The distribution pipe will be .5' above the surface. Coarse sand will be required to replace organic material removed and to raise the bed as necessary to provide the proper separation. A minimum of 3' of cover will be placed atop the bed and a minimum of 4' of cover will be placed atop the new septic tank. Additional test holes will be placed during construction of the septic system to verify the location of the alternate absorption bed will meet municipal requirements. Copies of the Lot 7, Block 5, Mountainside Village Subdivision March 6, 2005 Page Two test hole logs and percolation tests will be provided with the as -built for the system. The ground surface on the lot slopes at grades from east to west at steep grades on the eastern portion of the lot. The ground slope is shallower in the area of the proposed bed and estimated at 10% or less. The new absorption trench will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed 100' from all wells and 100' from any surface water. It will also be constructed a minimum of 10' from any water service in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Wltdt.u.LL OF'Qa--, Michael E. Anderson, P.E. Attachments 49th MICHAEL E. ANDERSON 44 No. CE -4381 1 System Requirements, 1,250 Gallon Septic 80' Long x 15' Wide NOTEc No Conflicts With Neighboring Wells and Septic Systems. SITE PLAN SCALE V = 80' "4o Tank Absorption Bed 4': 49th No. CE- 381 d tax y A 104 o 0-00 Tk2 A O mt~. Sy00< f Y Wkm 91. r 3' 06.0 IOx II I BI room ome III o 11 11 JI TMI FA ELEV. ISOo eo• tea'• u• w. in.apum &a lox \ ewe •� O �1 •••,gyp'.,....... SYSTEM DETAIL `��; � 49th • SCALE V = 40' i.............~ � . µ A • 01PANIOVD- E N1oFRSON •t C.i �• #, f?., No. CE-6781 I, • Existing Ground LOT 7, BLOCK 5, MOUNTAINSIDE VILLAGE SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: 4 Bedroom Home Shallow Bed System Pere. Rate: 6-8 MinAnch 1,250 Gallon Septic Tank Application Rate: .5 GPD/SF Coarse Sand (As Required) 4 Bedrooms X 150 GPD/.5 GPD/SF =1,200 SF Absorption Area 1,200 SF/15 SF (Width) = 80 LF Bed Length THEREFORE: Construct an 80' Long x 15' Wide Shallow Bed as Shown Below. Place Distribution Piping at Original Ground Surface. Remove Organics and Place Coarse Sand to Provide 6' Separation From Bedrock (Minimum). Place Insulation and 2' of Cover Over Bed or Mound Over Bed Minimum of V. Place 4' of Fill Over Tank. .5' .5' As Required Top 6' of Mound Must Be Topsolled and Vegetated to Prevent Erosion. Natural Backfill 2' Insulation & 2' Cover (Min.) O O O Drainfield Rock 4 - Coarse Sand (See Specification) In Situ GP Soil 2.5' V 5' 2.5' PVC TYPICAL BED SECTION (NO SCALE) NOTE: Grade Area Surrounding Bed to Drain Away. : it Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater, i 71 Minimum 100' Separation From Wells in the Area. i"ag"" Minimum 100' Separation From Surface Water or Streams. A6, Minimum 10' Separation From Water Service Line. 16-1 Existing Michael E. Anderson .ti No. CE4381 _ i ALASKA WATER R WASTEWATER CONSULTANTS, INC. SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: MOUNTUWSIDE VILLAGE SUBDMSION; BLOCK 5, LOT 7 PERFORMED FOR: JAMES B. EAVES DATE: 6/8/2003 (r B�TC11 ORGANICs TEST HOLE 1 1 2 M SIIJIGM/SM MIXED WI LOAM ( BEDROCK 10 11 12 13 14 15 IN 19 DEPTH TO DATE GROUNDWATER DRY 8/8/2003 t:� t + TH#2 + TH#1 TEST HOLE LOCATIONS ARE APPROXIMATE DATE READING CLOCK TIME I NET TIME (MINUTES) IIIIIIIII NET DROP (INCHES) 8/11/20031 1 I 1611111 WWI - rzz� Hum 111111111 1 1/20 ��y�� ;:7YYL5)i1/i 'fllil�)i �idB � 6- — 4 DEPTH TO DATE GROUNDWATER DRY 8/8/2003 t:� t + TH#2 + TH#1 TEST HOLE LOCATIONS ARE APPROXIMATE DATE READING CLOCK TIME I NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 8/11/20031 1 4:34 - 6- - 2 5:04 30 1 1/20 4 1/2" 3 5:04 — 6- — 4 5:34 30 1 1/2- 4 1/2" 5 5:34 - 6- - 6 6:04 30 1 1/2" 4 1/2" PERCOLATION RATE 6.7 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 1.5 FT. AND 2.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: JOE MARCHETTI COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ALASKA WATER & WASTE W WATER '� •• ?- CONSULTANTS, INC. SOIL LOG — PERCOLATION TEST ...... DO r LEGAL DESCRIPTION: MOUNTIANSIDE VILLAGE SUBDIVISION; A. Gaess:' SION; BLOCK 5, LOT 7 Q a JAMES B. EAVES DATE: 8/8/2003 C —7953 ••.• �F< PERFORMED FOR: '•.. ..• DE ��__ p,ofes510�°o (fee- hTrral ORGANICS TEST HOLE 2 040000�� 1jzzzz 2 11 n/ SOIL CLASSIFICATIONS ------------- ------------------ 3 ..in-_ GP ML GM/SM GM CL MIXED W/ GC OL 4 LOAM °• •°• o SW MH �<v� Q 5 '• �'• : SP CH STH#2 SM i OH v% 6 Sc � BEDROCK �v� +TH#1 DEPTH TO DATE GROUNDWATER g DRY 8/8/2003 cY B z °3 TEST HOLE 9 LOCATIONS ARE APPROXIMATE 10 CLOCK NET TIME WATER LEVEL NET DROP 11 DATE READING TIME (MINUTES) READING (INCHES) 8 11 2003 1 4:34 - 6• - 12 2 5:04 30 2' 4- 13— 3 5:04 - 6• - 4 5:34 30 2• 4• 14 5 5:34 - 60 - 6 6:04 30 20 4• 15 16 17 18 19� PERCOLATION RATE 7.5 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 1.5 FT. AND 2.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: JOE MARCHETTI COMMENTS: PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ONSITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 7, BLOCK 5, MOUNTAINSIDE VILLAGE SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new absorption bed 80' long X 15' wide also at the location also shown on the Site Plan and at the configuration shown. The distribution line in the bed will be placed at the existing ground surface. A minimum of 1' of clean coarse sand must be placed below the bed to replace organic material removed. Additional coarse sand may be required to provide a minimum 6' separation from the bottom of the bed to bedrock. The new tank and absorption bed must be placed outside the 100' protective radius of the well on the lot. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,250 -gallon septic tank must be procured from an approved source and installed at the location shown if the existing septic tank is found to be defective. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping F**L4*fl 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Lot'7, Block 5, Mountainside Village Subdivision March 6, 2005 Page 2 of 3 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: The drainfield shall be constructed to the dimensions shown on the design. The bottom of the bed shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 7, Block 5, Mountainside Village Subdivision March 6, 2005 Page 3 of 3 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (rypar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. COARSE SAND: 1. Coarse Sand must be graded as follows: 50% Passing No. 4 Sieve 3% Passing No. 100 Sieve 1% Passing No. 200 Sieve INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. . (ENGINEERS SEAL) • e Municipality of Anchorage tey4 a DEPARTMENT OF HEALTH & HUMAN SERVJGES..�j�/�% ; 825 "L" Street, Anchorage, Alaska 99502-0660'..// SOILS LOG —PERCOLATION TESTTa �,,`? �. s •. 4:-��. r - PERFORMED FOR: A Ce- f} �� S�S� r x4 s- DATE PER FO RMJ=E; O ti J J� LEGAL DESCRIPTION: / (`-f 7 �CG Township, Range, Section: DEPTH ,r"1 �,I//,, (/rt �- r 1�GPE SITE PLAN 0 "�R.��l --CC//] 2 e- SLO 1 O O E 2- 3- 4- 5- 6- 7 34 567 8- 9- 10- 12- 13- 14- 15- 16- 17- 18- 19- 20 - COMMENTS 910 121314151617181920COMMENTS s gy-nc�y 6 rc, uz( O't I o4 Sij+ 5rn4l l S -to,GS i Ufs�4iiy ��.f� cLF /5D WAS GROUND WATER (� ENCOUNTERED?' �rx� wt S L to' IF YES, AT WHAT O DEPTH? P E Depth to Water After Monitoring? Date: Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT ANP FT r r PERFORMED BY:--)zaae ' %La- S 0 ' �t"t'uASERTIFY THAT THIS TES WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES W EFFECT ON THIS DATE. DATE:�----- 72-008 (Rev. 4/85)