HomeMy WebLinkAboutVALLI VUE ESTATES #2 BLK 1 LT 47Valli Vue Estates Block Lot 47 #015-123-02 Municipality of Anchorage ..,.~. ·-' : t-:,.....:~'.. Development Services Department Building Safety Division On. Site Water and Wastewater P,,og ram. 4700 S. Bragaw SL P.O. Box 196650 Anchorage. AK 99519-6650 Page www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number:' .~l,l~:~lo.~y~ PID Number: "*'~'~-'et>Q~'~ L~ Ro~rj.,~to..~/gat'~ WastewaterSystem: DNew [~Jll Upgrade '~""~6'~.0 C~:~o ~ Tt'~e P,". ~ ~q~'~g' ABSORPTION FIELD LEGAL DESCRIPTION ~ Well: D New ~ Upgrade ~: ~.~' ~ TANK ~ ~1~ SEPARATION DISTANCES ~ septic D Holding ~ S.T.E,P. ~ Othe~  Septic Abso~tion Lift Holding Pu~vate ~ Tank Field Station Tank S~r Une s¢~,,. ~/~, >1~' - - ~ / LIFT STATION ~ll g.n ~v~ ~lu~ l~ll~ BENCH MARK Engineers Stamp ,nspectionspeHormedby: ~/o~ r-c4 ~--c. Dates: 1" Development Semices Depa~ment Approval ~ ~o.e ~ ~i~ Reviewed and approved by: ~~ ~ P~Date:, PERMIT NO: SW010349 PAGE 2 OF 2 PID NO: 015-123-02 EXISTING SOIL ABS. TRENCH (1983) EXISTING 1973 SEEPAGE PiT EX~sT~NG 19~3 SEPTIC TANK DRIVE NEW 24' LONG SOIL ABS. TRENCH W. 9.6' GRAVEL BELOW DIST. PIPE NEVV 30' LONG SOIL ABS. TRENCH W. 9.1' GRAVEL BELOW DIST. PIPE PLAN VIEW SCALE: 1" = 30' TIES: FROM: COR."A" COR."B TO: VALVE "E" 20.5' 34' TR. C.O. "F" 76' 63' TR. M.T. "G" 89.$' 78' TR. C.O."H" 101' 91' TR. C.O. 'T' 71' 70.5' TR. M.T, "J" 89.5' 89' TR. C,O. "K" 93' 92' CROSS-SECTION NOT TO SCALE INV. 9.1' SEWER GRAVEL 9.6' SEWER GRAVEL BOT. TR. 83.0' (14' B.G.L) BOT. T.H. #1 ELEV. 77.8' DRY 914/01 FROM EXIST. INV. BOT. TR. ELEV. 84.0' LOT 47, BLOCK 1, VALM VUE ESTATES #2 SEPTIC SYSTEM UPGRADE AS-BUILT INSPECTION REPORT FLA'I~I'OP TECI INICAL SERVICES 14530 ECIIO STREET ANCI IORAGE. ALASKA 99516 SCALE:AS NOTED DRAWN BYTFM SEPTEMBER, 2001 MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Aug 29, 2001 Expiration Date: Aug 29, 2002 Permit Number: SW010349 'Legal Description: VALLI VUE ESTATES #2 BLK I LT 47 Design Engineer: 0019 Flattop Technical Se~ices Owner Name: George & Roberta Spartz Owner Address: 6620 CROOKED TREE DRIVE ANCHORAGE, AK 99516-6801 Parcel ID: 015-123-02 Site Address: 006620 CROOKED TREE DR Lot Size: 24859 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage ~JI construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Permit Number SW0! O'~'~"~ Property owner(s) ~--~r~' Mailing address (1) 6",5y?-a~ Mailing address (2) ,4n Legal description (Lot, Block & Sub'd.) Legal description (Section, Township & Range) Lot Size ~q' ~,, Acre~ THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Day phone '~s,~- Number of Bedrooms Well Only Water Storage Jacuzzi Water Softening Unit I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of proper~ owner or authorized agent) Permit Fees: .~ ZE7 ~ Waiver Fees: '~//15"' ~/o ~t ~l.' ~ Date of Payment: ~/~_ ~./~t Date of Payment: Receipt Number: (Rev. 12/00) Receipt Number: Municipality of Anchorage George P. Wuerch, Mayor Building Saf¢~, Division P.O. Box 190380 · 4700 S. Bragaw Street Anchorage, Alaska 90519-~ · (907) g4~-8301 htt p://www.ct.anchorage.ak.us ~epartment o~ Public Worlc~ 8/29/2001 Ted Moo~e P.E. Flattop Technical Services 14530 Echo St. Anchorage, AK 99516 Subject: Waiver Request for Valli Vue Estates #2 Block I Lot 47 Waiver Request #WR010069 Pamel ID #015-123-02 Permit #SW010349 Dear Ted Moore: Your request for a waiver of the required 10 feet horizontal separation from the absorption field to property line has been approved. The approved separation distance is 1.0 foot. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require ail separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343'7904. Si ly, ' . ~nes Cross, P.E ' ~rogram Manager On-Site Water & Wastewater Program Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Waztewatcr Program 4700 Bragaw S~rect P.O. Box 19~$0 Anchorage, AK 995194650 www.ci.~nchorage.ak.us (907) 343-7904 Waiver Review Worksheet WRY: WR010069 PID~: 015-123-0:~ I-LA,#: Date Received: 08122/~1 Legal Description: Valfl Vue Estates {~2 Block I Lot4? Enalneer: Ted Moore P.E.. Flattoo Technical Servic-~-- 14530 Echo St Anchoraae. AK Applicant: Waiver Requested: 1 foot from lot line to absomtlon field PermO: SW0 IO Ur l Criteria: Geology A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Points: Total: Rec~: ~971 Amount: $115.00 Date Paid: 8~2/2001 Llst Conditions or Reasons for above: ~ ~'~/~_IAJ~"~.'~, £C-~'~w'"~ ~ CIVIL & ENVIRONMENI'AL ENG~EER~NG * ENERGY CONSERVA'i']ON & ANAL~I~ THEODORE F. MOORE, P.E. PII: (907) ~45-1355 M.O.A. F_d4~'S P.O. Box 19-6650 Anchorage, AK 99519 August 22, 2001 14530 ECHO ST. ANCHORAGE, ALASKA 99516 Dear Sirs: The purpose of this letter is to provide the required design narrative in support ofour application for a permit to upgrade the wastewater disposal facilities on Lot 47, Block I, Valli Vue Estates, Unit #2, located at 6620 Crooked Tree Drive. The existing system is operating in a slightly surcharged condition. We are also requesting a waiver allowing the new soil absorption system to be constructed within 1.0 feet of the lot line common with Lot 46. Soils logs, pere test results, a site plan, design drawings and specifications are enclosed for your review. The proposed system will be constructed in the vicinity oftest hole # 1. As cab be seen from the soil log, the native material below 9.5 feet is a slightly silty sand with a measured pete rate of less than 1 minute per inch. No sand filter should be necessary because the native material is already sand. The native material above 9.5 feet is a sandy silt with a measured pere rate in excess of 60 minutes per inch. Using the soil application rate of 1.2 gpd/sq, ft. specified in the wastewater ordinance for soils that pere faster than 5 minutes per inch, this 3-bedroom residence requires a total absorption area of(3 x 150)/1.2 = 375 square feet. The proposed 50 feet of trench has an effective absorption area in the sand stratum between 9.5 feet and 14.0 feet depth of 450 square feet. We propose to actually fill the trench up with sewer gravel to 5.0 feet to provide a safer working environment as well as some additional absorption capability in the silt stratum. The topography of the lot in the area of proposed construction slopes downward toward the northwest at approximately 10% along the lot line common with Lot 46. The requested lot line waiver down to i foot is necessary in order to allow construction of a 30-foot long trench in the location shown, and to maximize efficiency of utilization of deep sandy soils in this area. Since all lots in this subdivision are served by a Class "A" Community water system, granting the waiver will have negligible impact on the ability to construct replac, ement wastewater disposal systems on Lot 46. The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any significant impact on reserved space-surface and subsurface, or on drainage. Please give me a call at 345-1355 ifyou have any questions on this submittal. Sincerely, Ted Moore, P.E. LOT 7, BLOCK 5 LOT 8, BLOCK 5 LOT 6, BLOCK 5 LOT 9 BLOCK 5 LOT 5, BLOCK 5 / / / / / / / WALLS ? ? / DRIVE D AREA~ T.H. #1 SEPTIC AREA NOTE: ALL LOTS IN THIS SUBDIVISION ARE SERVED BY A CLASS "A" WATER SYSTEM LOT 47, BLOCK 1 VALLI VUE EST. #2 __ EXISTING SOIL ABS. TRENCH (1983) " 25%' SEPTIC AREA / ,' ' LOT48 ; _ EXISTING 1000 GAL. ,' SEPTIC TANK (1993) INSTALL D'VERTER ~ 4" INSULATION + 4' SOIL COVER OVER WASTE LINE UNDER DRIVE CONSTRUCT 50' SOIL ABS. WITH 9' GRAVEL BE3~N. 5' AND 14' & 3" "BUMF~' IN CONNECTING PIPE LOT 49 / __ EXISTING CONCRETE / ;EEPAGE PIT / / / //// 47, BLOCK 1, VALLI VUE ESTATES, UNIT #2 SEPTIC SYSTEM UPGRADE SITE PLAN FLATTOP TECII~CAL SERVICES I INCH = 50 FEET 14530 ECIIO STREET DRAWN BY TFM ANCI [ORAGE, ALASIC~ 99516 AUGUST, 2001 NOTE: THIS IS NOT A SURVEYED PLAT. ALL LOCATIONS SHOWN ARE APPROXIMATE. INSULATE 4" DIA~ D-3034 W. 4" RIGID FOAM + 4' SOIl -- COVER UNDER PAVEMENT INSTALL "BULL RUN" DIVERTER VALVE EXISTING 1000-GALLON--7 SEPTIC TAN~ EXISTING / DOUBLE C.O. 4" DI~ F-810 PERF .iA- CONSTRUCT 3" BUMP IN 13-3034 CONNECT 20 rc.o. M.T. TO EXISTING SEEPAGE PIT AND TRENCH PLAN VIEW SCALE: 4" = 10' ............ C.O. "A" L~ M.T. -- CONSTRUCT TOTAL 50' LONG x 14' DEEP SOIL ABSORPTION TRENCHES WITH DISTRIBUTION PIPE INVERTS {~ 5.0' ORIGINAL GROUND FILTER FABRIC 4" DI/L F-810 PERF. DISTRIBUTION PIPE 1/2" = 2 1/2" SEWER GRAVEL BOTTOM OF ML/SM STRATUM 10 MIN. CROSS-SECTION "A" - "A" SCALE: 1" = 5' TOP OF SP/SM STRATUM BOTTOM OF TRENCH EXCAVATION LOT 47, BLOCK 1, VALLI VUE ESTATES #2 SEPTIC SYSTEM UPGRADE PLAN AND CROSS-SECTION FLATTOP TECIINICAL SERVICES SCALE: AS SI IOWN 14530 ECIIO STREET DRAWN BY: TFM ANCIIOP, AGE. AK. 99516 AUGUST, 2001 FLATTOP TECHNICAL SERVICES 14530 ECHO '~ ~ ~CHO~GE, A~S~ 99516 TEST HOLE ~ ! ~ SOILS LOG -- PERC~T~S LEGAL DESCRIPTION: Lot47 Block1 ValliVueEstat~ Un~ DATE PERFORMED: ~ugust~4 2001 PERFORMED FOR: G~Ob~pa~ t 2' 3' 4- 14- Pt. SLOPE SITE PLAN SM Reddish sandy loam (ltuffy) 2~ MI/SM Gray sandy silt Dense, lenses of sandier soil T.H. SP/SM SIigh~ si~ sand Cleaner below 14' 19- 20- 20,5' -- Depth to Groundwater Date No_grpundwater 8/14/01 -Monrt~r t0b~dry ' 8/2~/01 Clock Time PERCOLATION RATE <1 (minutes/Inch) PERC HOLE DIAMETER. TEST RUN BETWEEN 95 FTAND 10.0 FT COMMENTS: Perc rate is less than 1 min./inch based on fact that 12" presoak water co,,plete~y al~s~o[bed twice within 2 minLfles. No sand filter should be required since the native material is sand. A second perc test conducted between 5.25' and 5.75' showed >60 min./inch. PERFORMED BY FLATTOP TECHNICAL SERVICES. I ~"".,~¢,,~,~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUiDEMNES iN EFFECT ON THiS DATE. DATE: q:fattop r[ec~nicaf Services 14530 ~c~o Street, fllnc~orage, .~7~ 99516 ct'~one (907) 345-1355 Lot 47, Block 1, Valli Vue Estates, Unit #2 6620 Crooked Tree Drive Wastewater disposal system installation Specifications 1.0 General: 1.I The scope ofthe project consists of installation ora diverter valve downstream ofan existing septic tank and construction oftwo 14-foot deep soil absorption trenches with a combined length of 50 feet and an effective gravel depth of 9 feet. 1.2 Construction shall be as depicted on the approved sitq plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All construction procedures and material specifications shall conform to Municipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. The required separation distance from the lot line common with Lot 46 is 1 foot. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any buffed utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement oftopsoil and reseeding all areas disturbed by the construction. The homeowner shall also be responsible for repaying the cut in the driveway. 2.0 Septic Tank: 2.1 The existing 1000-gallon septic tank may be retained in service since it is only 8 years old. 2.2 A "Bull Run" diverter valve shall be installed downstream ofthe existing double cleanout allowing septic tank effluent to be periodically switched back to the original seepage pit and trench at the discretion ofthe owner. 2.3 All portions ofthe new 4" diameter ASTM D-3034 discharge line to the new soil absorption trenches that underlie driveway pavement shall be laid at least 4 feet below final grade and also insulated with 4 inches offigid foam insulation, two feet wide. The trench in this area shall be baekfilled with non frost-susceptible soil that has been thoroughly compacted in 12-inch lifts. The owner shall be responsible for arranging to have the cut in the pavement repaired. 3.0 Soil absorption system: 3.1 The soil absorption system shall be constructed by excavating two trenches with a combined length of 50 feet to a depth of 14 feet below ground surface. 3.2 The long axes ofthe trenches shall parallel a natural contour ofthe land, and the bottom of the excavations shall be level. 3.3 A total of 9.5 feet of approved sewer gravel shall be placed in the bottom ofthe excavations with the perforated distribution pipes laid level such that the pipe inverts are no less than 9 feet above the bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the #200 sieve. 3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on the design drawings. The portion ofthe monitor tube extending through the sewer gravel shall be perforated. 3.5 Approved filter fabric shall be placed over the entire top surface ofthe sewer gravel. A minimum of 2 feet ofsoil cover is to be placed over the filter fabric. Ifthe soil cover thickness is less than 3 feet, two inches of rigid, burial type insulation is to be placed over the entire top surface ofthe gravel, in addition to the filter fabric. 3.6 The top surface ofthe cover material shall be raised a minimum of 6 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill slopes shall be no steeper than 3:1. 3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have the site finish graded after the backfill material has stabilized, and for placement ofadequate topsoil and seed to promote rapid revegetation ofall areas disturbed by the construction. 4.0 Inspections: 4.1 A minimum of 4 engineering inspections will be required during the course of the project: (I) initial stakeout with the contractor to establish the location ofthe system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it is level and at the fight elevation, and conforms with the soil test information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and grading is complete. 5.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: _%t,e./ c2.Z, 031~ PlDNumber: 0 ~5'1 I Name: ~ ~ ~o~ ~/z Wastewaler System: D New D Upgrade. Address: v ~eo C~ ~r~e ~. ~c~ ~t~ ABSORPTION FIELD Phone: ~--17~ INo'oIB~dr°°ms: ~ Deep Trench ~ Shallow Trench ~Bed OMound.~Other LEGAL DESCRIPTION so,, ..,,~g: Total Oep~ Item Original grade: GPO/~q Ft Townsh,n: I~N.I Range: ~,I Seclion: IY Fi. added above original graOe: r,=Gravellength: WELL: D New D Upgrade.,;,'1""'"' o, .,..: Fl SEPARATION DISTANCES ~ Septic ~ Holding ~ S.T.E.P. Well ~ ~ ' i Ualenal: ~ ~E I wa~. > t~' LIFT STATION Line ~ ' I Foundation ~, 'Pump on" level at: I "Pump o,r',evel,t: I H,g~ wate, a,arm at: Curtain Remarks: ~.~ /~tl.~ ?. o~p~.~ BENCH MARK IOo. o ENGINEEW~ ~EAL Inspections performed by: Flat~p ~c4 F~c Dates: 1st ~/~g/~ E *: ~9 e~a~d 2nd ~.~; ~ ~ ~1H~O~O~ Deparlment of H Huma~ervices appro~a~ e~,,,,j 'c~.a~s~ Reviewed and approved by: ~J ~. Date: '~;~r ....... PERMIT NO: SW930310 PID NO: 01512302 EXISTING TRENCH EXISTING SEEPAGE PIT HOUSE / / / / / / ! PLAN VIEW SCALE: 1" = 30' ~ GROUND SURFACE @ 102' 97.85 1000 GAL. 97.51 PROFILE VIEW VERT SCALE: 1" = "B PAGE'2 OF 2 / ! ! ! ! / ! ! ! ! ! ! ! NEW 1000 GALLON SEPTIC TANK SWING TIES FROM: -TO: C.O. "C" COR. "A" COR.';B'' C.O. "D" 14' 30' 18' 32' LOT 47, BLOCK 1; VALU VUE EST #2 SEPTIC SYSTEM UPGRADE AS-BUILT INSPECTION REPORT FLATTOP TECIINICAL SERVICES 14530 ECItO STREET ANCHOR. AGE, ALASKA 99516 DRAWN BY TFM SEPTEMBER, 1993 PAGE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 #L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW930310 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:SPARTZ GEORGE P & ROBERTA A OWNER ADDRESS:6620 CROOKED TREE DR ANCHORAGE, AK. 99516 DATE ISSUED: 8/19/93 EXPIRATION DATE: PARCEL ID:01512302 LEGAL DESCRIPTION: VALLI VUE ESTATES #2 BLK 1 L T 47 LOT SIZE: 24859 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4329 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. 1 OF 8/19/94 1 SPECIAL PROVISIONS: RECEIVED BY: ~ ~ LOT 4 LOT 6 BLOCK 5 / / / ! ! ! LOT 46 / / / / / / / / / TRENCH SEEPAGI LOT7 / l [ LOT 8 ~" '~' LOT 47 , , \ BLOCK 1 ,' ,' \ LOT 48 EXISTING 1000 GAL. SEPTIC TANK TO BE ABANDONED AND REPLACED WITH NEW S.T. LOT 49 20 0 20 40 60 '80 100 FEET LOT 47, BLOCK 1, VALLI VUE EST,#2 SEPTIC TANK REPLACEMENT..' SITE PLAN "- FLATTOP TECHNICAL SERVICES 1 I~Cl.~. 50 FEET 14530 ECItO STREET . DRAWN BY TFM ANCHORAGE, ALASKA 99516 AUGUST, 1993 NOTE: THIS IS NOT A SURVEYED PLAT, ALL LOCATIONS SHOWN ARE APPROXIMATE.  ~ MUNICIPALITY OF ANCHORAGE ~' DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME MAILING ADDRESS LEGAL DESCRIPTION LOCATION NO. OF BEDROOMS DISTANCE TO: ~ Well ~ Absorpl,on area D~liing PERMIT NO.  Uanu f~turer Material No. of Liq. capacity in gallons inside length Width IF HOME.DE: Liquid depth ~ ~ DISTANCE TO: Well Owelling PERMIT NO. O z ~ Manufacturer ~ -- ~ Material Liquid capacity in ~Hons ~ Well Foundation i Neerest~o~ne PERMIT Total lengt~of~nes T~ench width Distance ~t~en lines ~ DISTANCE TO: Well Building foundation Nearest lot line ~ DISTANCE TO: Building foundation Se~r line Septic tank Absorption area(si OTHER PIPE MATERIALS INSTALLER APPHOV E D~ DATE LEGAL PE, RMIT NO. · FIUN ~ ~ ~ PAL T T~r· OF- FihlBHCiRI~ii~iE DEPARTMENT ~ HEALTH AND ENVIRON~'IEHT~L ~OTECTION 825 ': ~ STREET, ANCHORAGE, AK. 9~ Il 264-4~20 Ot~--S I TE SE~qER PERi4 I T ( 830413 ) APPLICANT LOCATION LEGAL ROBERT ARNOLDS L47 Bi VALLI VUE TYPE OF SOIL RBSORPTIOt.~ SYSTEM IS: 203 Pi 15TH 99501 LOT SIZE TRENCH 999999 SQUARE FEET MRXINUM NUMBER OF BEDROOMS = 3 SOIL RATING THE REQUIRED SIZE OF THE SOIL ABSORPTIOt,I SYSTEM IS: DEPTH= '1:1_ LENGTH= 3:::) GRFIVEL DEPTH= THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUMD AND THE BOTTOM OF THE EXCAVATION (IN FEET)· THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRRVEL BETWEEN THE OUTFRLL PIPE AND THE BOTTOM OF THE EXCRVRTION (IN FEET). RE~.. LI 1' RED SEPT 1' C TRt~t.-.. S ! :::'E= :L000 i:~iRLLOI'-,IS PERhlIT APPLICANT HRS THE RESPONSIBILITY TO INFORM THIS DEPRRTMENT DURING THE INSTRLLRTION INSPECTIONS OF RtlY WELLS RDJRCENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE ~IELL WILL SERVE. TI40 (2 > I hlSPECT I Obis REE RE(;~U I I;~ED BACKFILLING OF RNY SYSTEM WITHOUT FINAL INSPECTION RND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEM R WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS · lc:~O FEET FOR R PRIVATE WELL OR 150 TO 200 FEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL MINIMUM DISTANCE FROM A PRIVRTE WELL TO R PRIVATE SEWER LINE ,IS 25 FEET AND TO R COMr~UNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRRM$ RRE RVAILRBLE TO INSURE PROPER INSTALLATION. PERI'! I T E×P I RES DECEr~IBER 3:1_. I 3~_'3 I CERTIFY THAT l: I RM FAMILIAR WITH THE REQUIRE~IENTS FOR ON-SITE SEt~ERS AND WELLS RS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. ~: I UNDERSTAND THRT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN ~ BEDROOMI S I GNED: ____~__-__~_ LICA~ ROBERT RRNOL[~S- ,F~'.R ANCHORAGE AREA,-~O~!GH Department of Environmental (~uality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION ~.~~____~ SEPTIC TANK: MAILING ADDRESS /~) . LEGAL DESCRIPTION~ DISTANCE C~ /U)~'~'7'' FROM WELL .MANUFACTURER MATER,AL COMPARTMENTS ~ lTql~Z INSIDE LENGTH INSIDE WIDTH _LIQUID DE~H~IQUID CAPACITY~ ~GALLONS. SEEPAGE PIT: NUMBER OF PITS / DIAMETER LINING MATERIAL~'O-4~/'#~f;~:;~CRiB SIZE, BUILDING FOUNDATIOi~.~~'/ , OR W~DT, LENGT, DEPT, / / DIAMETER DEPTH .~ DISTANCE FROM: WELL - NEAREST LOT LINE ~0'"'{" TOTAL EFFECTIVE · ABSORPTION AREA (WALL AREA) ~7~/~7Z- SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE BUILDING FOUNDATION CESSPOOL APPROVED CONSTRUCTION NEAREST LOT LINE OTHER SDURCE$ DISAPPROVEO DEPTH DISTANCE FROM: NEAREST SEPTIC SEEPAGE SEWER LINE TANK SYSTEM -- REMARKS. DISTANCES: I NSTA L LEO B y; .~t7) ~;;fiP,~2 LOT SLOPE:, REMARKS:, Form NO. LQ-031 DIAGRAM OF SYSTEM GreATEr ANCHOrAgE Area BorOugh SEWAGE DISPOSAL SYSTEM ~ APPLICATION AND PERMIT PERMIT NO FINAL INSPECTION: 2:4 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC 'rANK TO SEEPAGE PiT WALL D.AIN F,ELD DRAIN FIELD SEEPAGE PIT /~ . ALSO CONSIDER AREA WELLS, SEEPAGE P~T / A DRAIN FIELD "'~7/~/~ /// DIAGRAM OF SYSTEM CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL, GRAVEL BACKFILL ~.'ATER ANCHNRAGE AREA DEPART~!EIIT OF ENVIRON~IENTAL QUALITY 3500 TUDOR ROAD ANCHORAGE, ALASKA 99502 CASE # Legal Descrintion: Lot ~/~ Bloc~: / This Form ReQorts Soils Log Date Performed ~-~')] ~Subdivision 0~/~' Ou~ Percolation Test Qeoth Feet Soil Characteristics 5~ 8~ 9__ Was Ground Water Encountered? If Yes, At what Depth? I Readin~l Date Gross Time Net Time Depth to H20 tlet Dron co Rate ~linute Proposed Installation: Seenane Pit De~th of Inlet Denth To CAM~ENTS: Drain Field Bottom Of Pit Or Trench Test Performed By Data Certified By: Date: Certificate of On -Site Systems Approval Parcel I.D. 015-123-02 1. GENERAL INFORMATION Expiration Date:. 3 Complete legal description VALLI VUE ESTATES #2 BLOCK 1, LOT 47 Location (site address) 6620 CROOKED TREE DRIVE, ANCHORAGE, AK 99507 Current property owner(s) CHRISTINA H. MAY Day phone Mailing address Real estate agent 6620 CROOKED TREE DRIVE, ANCHORAGE, AK 99507 Day phone 2. TYPE OF DWELLING: Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well El Private Septic Water Storage El Holding Tank ❑ Community Well Community ❑ Public Water System ❑ Public Sewer Waiver request for: Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the.engineer. COSAFee $ 'flZ,90 e-OVID Date of Payment, 3 0/,?, 0.20 Receipt Number () 35 COSA# 05GZQ1,537 Date: Waiver Fee $ Date of Payment Receipt Number Waiver # COSA Checklist Legal Description: VALLI VUE ESTATES #2 BLOCK 1, LOT 47 Parcel ID: 015-123-02 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA – CLASS A WATER SYSTEM Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date of Sample Comments __________________________________________________________________________________ B. TANK DATA Age of tank(s) 27 years Tank type/material SEPTIC / STEEL Measured operating fluid level in septic tank 49” Standpipes/foundation cleanout per record drawing Date of pumping 9/7/2020 C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: SEE MOA TANK ADVISORY D. ABSORPTION FIELD DATA Which system tested (date installed) 9/4/2001 ALL standpipes present per record drawing Total measured depth from grade 15 / 13.3 ft (max) Measured depth to pipe invert from grade 5.7 / 3.6 ft (min) N/A – pressurized field Monitor tubes go to bottom of effective. If not, state depth into effective Code-required soil cover over field System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Adequacy test date 9/7/2020 Results Pass For 4 bedrooms Fluid depth prior to test 50 / 0 in Water added 600 gal New depth 73 / 0 in Elapsed time 1320 min Final fluid depth 48 / 0 in Absorption rate 600 gpd Any rejuvenation treatment (past 12 months) N If yes, enter date Comments/Deficiencies:. EAST / WEST TRENCH – West trench dry. E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No 7’ ft Property Line > 5’ Yes if No ft Absorption Field > 5’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10’ Yes if No ft Property Line > 10’ Yes if No *2 ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft If absorption field is under driveway comment below Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No F. ENGINEER’S COMMENTS *MOA WAIVER. G. ENGINEER’S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. 9/30/2020 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 907-343-7904 On-Site Water and Wastewater Section Fax: 343- 7997 www.muni.org/onsite Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519-6650 * www.muni.org Septic Tank Advisory Certificate of On-Site Systems Approval # OSC201537 Subdivision: Valli Vue Estates #2 Block:1, Lot: 47 The septic tank for this property is 27 years old. The average life for a steel septic tank is 20 years. Typical replacement costs range from $7,000 to $11,000. This advisory must be attached to all copies of the subject Certificate of On-Site Systems Approval. This is an example of what the metal of a 30 year old steel tank MAY look like. Municipality of Anchorage Development Services Department ' Building Safety Division ~- On-Site Water & Wastewater Program / 4700 Bragaw Street ~" P.O. Box 196650 4_-~------~-," /.~ Anchorage, AK 99519-6650 /j./,? /) www.muni.org/onsite / (907) 343-7904 /// CERTIFICATE OF ON-SITE SYSTEHS APPROVAL FOR A SINGLE FAHILY DWELLING Parcel I.D. 015-125-02 1. GENERAL INFORMATION COSA# ~..~-~ (~/ Expiration Date:__ 'Complete legal description VALLI VUE ESTATES #2; BLOCK 1, LOT 4-7 Location (site address) 6620 CROOKED TREE DRIVE * ANCHORAGE, AK * 99507 Current Property owner(s) MARK KORNMESSER & VALERIE WALDROP Day phone 227-0655 Mailing address 6620 CROOKED TREE DRIVE * ANCHORAGE, AK * 99507 Lending agency Day phone Mailing address Real Est~teAgent LONNIE LOGAN W/ REMAX Day phone ' .'MailidgCddress 110 W. 38TH AVE, #100 * ANCHORAGE, AK * 99505 · :~' i' Unless othetwige requested, COSA will be held by DSD for pickup. 2.. NUMBER OF BEDROOMS: 3 257-01 14 .3. 'TYPE oF: WATER SUPPLY: Individual Well [] Individual Water Storage [] Community Class A Well · Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site · Individual Holding tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 5701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Date Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate dudng the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DSD SIGNATURE \,/ Approved for bedrooms. Disapproved. Conditional approval for ~ :. PROGRAM ..' bedrooms, with the following stipulations: ~,..,,~?o. Wjj)))))))))) ~, Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory (Rev. 11/05) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: ,Municipality of Anchorage Development Sentices Department Building Safety Division On-Site Water & Wastewater,Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF 0N-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: VALLI VUE ESTATES #2; BLOCK 1 LOT 47 Parcel ID: A. WELL DATA ICOMMUNITY WELLI Well typeCOMMUNriY IfA, B, orC provide PWSID# 210605 Well Log (Y/N) Date corn pleted Total depth Date of test Static water level Sanitary seal (Y/N) Wires properly protecte~)_J Cased to .ft. Casing he__round) in. FROM WELL LOG AT I~PL~TION .~~ ~.p.m. g.p.m. Well production WATER SAMPL~ Colh~orm ~ colonies/lO0 mi. ~ ug./L. Nitrate mg./L. Other bacteria Date of sample: Collected by: colonies/100 mi. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Tank size 1000 gal. Number of Compartments 2 Foundation cleanout (Y/N) YES Depression over tank (Y/N) Date of Pumper NO Date installed 8/23/1993 Cleanouts (Y/N) YES High water alarm (Y/N) N/A MCDONALDS PUMPING ABSORPTION FIELD DATA I'BELOW EXISTING GRADEI Date installed, ,9/4/2001 Soil rating ~r ft2/bdrm) 1.2 (30 & 24) Length 5O. TOTAL ff. Width 2,5/2,5 ff. '15.6/ Total depth 13.4 ft. Eft. absorption area 1006 ~t2 Monitoring tube YES Date of adequacy test *'8/11/2010 Results (Pass/Fail) PASS System type DUAL TRENCH Gravel below pipe 9.1/9.6 ft. Depression over field NO For 3 bedrooms Fluid depth in absorption field before test 49 in. Water added 450. gal. New depth 65 in. Elapsed Time: 150 min. Final fluid depth 54 in. 'Absorption rate >-- 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date - **TESTED EAST.TRENCH OF 1991 SYSTEM. WEST TRENCH (1'991) WAS DRY. NOTE: PREVIOUSLY DOCUMENTED CRIB AND DRAINFIELD ARE CONNECTED AS RESERVE SITE. OLD CRIB AND DRAINFIELD WERE NOT IN USE AND DRY. D. LIFT STATION Date installed "Pump on" level at in. E. SEPARATION DISTANCES Size in gallons Manhole/Access (Y~..~_) -- "Pump off" I~ High water alarm level at Cycles tested. Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: ICOMMUNITY WELLI Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer_/s~ ~ Animat'EEntain ment areas. On adjacent lots On adjacent lots ~eanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Water main 10'+ Water service line '10'+ Absorption field Surface water 5'+ 100'+ Wells on adjacent lots 200'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line *'1 '+ Building foundation. 10'+ Water service line 10'+ Surface water 100'+ Water main 10'+ Driveway, parking/vehicle storage 1'+ Curtain drain NONE KNOWN Wells on adjacent lots 200'+ F. COMMENTS *PER PREVIOUS C.O.S.A. EXACT LOCATION UNKNOWN. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date ~ /J~/I 0 **#WR010069. COSA Fee $ J"/~ Date of Payment Receipt Number Waiver Fee $ Date of Payment Receipt Number. (Rev. 11/05) A 8 Pt-IA~.T D~tVEWAY ! / / / / / / / / 1'90.53 t 1 / / / ? / t / 1 / / / / / / / / / / / / / O' AS-BUILT SURVEY NO CORNERS SET THIS DATE 1' MORTGAGEE'S INSPECTION OF TH~ ~:OtLOW1NG DESCRI~EC, E~flOAC~NT~ ~XIST OTHER TH~ NOTED, DATED A~ ~OEo ~S~ THI~ ~TH Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.munLorg/onsite (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-123-02 1. GENERAL INFORMATION Complete legal description HAA# ~' 0 ~[~,~ Expiration Date: Valli Vue Estates #2, BIk 1, Lot 47 Location (site address or directions) 6620 Crooked Tree Dr., Anchorage Current Properly owner(s) Linda & Mike Ward Day phone Mailing address 6620 Crooked Tree Dr,, Anchorage, AK 99507 Lending agency Mailing address Day phone Real Estate Agent Mailing Address Unless otherwise requested, HAA ~vfll be held by DSD for pickup. 2. NUMBEROF BEDROOMS: 3 Day phone 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class A Well Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank Community On-site Public Sewer The Municipality of Anchorage Development Se~ces Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon lhe representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Munidpality of Anchorage is not responsible for errors or omissions in lhe professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(am) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(am) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Fire1 Watkins Engineering, Inc. Address P.O. Box 110443, Anchorage, AK 99511-0443 Engineer's Printed Name Cindy W. Ellis DSD SIGNATURE .~--/~ Approved for B Disapproved. Conditional approval for Phone 349-1851 Date 720/05 bedrooms. bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory X Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: ~ --,~,- "~ - ~),~" Municipality of Anchorage Development Services Department Bu~lng ~afety Division On-Site Water & Wastewater Program 4700 Soulh Bragaw St. P.O. Box 196~50 Anchorage, AK 99519-6650 w~w. muni.ofg/onslte (907) 343-7gD4 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Velli Vue Estates fr2, BIk 1. Lo{ 47 A. WEll DATA Parcel ID: 015-123-02 Well type A IfA, B, otC Ixovide PWSID # 2~oao~ Well Log (Y/N) NA D~ Sanitary seal (Y/N) Wlms properly protected (Y/N) Total depth ~ Cased to fl. Casing height (above ground) in. FR~ AT INSPECTION Well pmduc~)n g.p.m. ~ g.p.m. WATER SAMPLE RESULTS: ~ Cotlfo~m NA colonies/100 mi. Nitrate mg.A. Other bacteria '",... coinnies/100 mi. Amenic: rog./1. Date of sample: Collected by: ~ B. SEPTIC/HOLDING TANK DATA Tank Type/Material ~teet sep~ tank Tank size 1000 gal. Foundation cteanout (Y/N) Y Date of pumping 616/05 C. ABSORPtiON FIELD DATA Number of Compartments 2 Depression over ~ank (Y/N) N Pumper Denall Pumpin~ Date installed 8/23/93 Cleanouts (Y/N) Y High water alarm (Y/N) NA Dateinstel]ed '9/5/01 Soilrating (g.p.d./ft2 orft2/txlrm) 1.2 Systemtype deeptrench Length 54 ft. W~dth 2.5 ft. Gmvel below pipe 9.1/9.6 fi. Total dep~ 13.5/14 ft. Eft. absorption area 1006 it2 Monitoring tube 2 Depression over field N Date of adequacy test 6/6/05 .l~esults (Pass/Fall) PASS , For 3 bad, rock, s Fluid dep~ in ~bso/~n fleid bofom test 45/o in.~ /~j Water added ~ gal. New depth e4~H in. Elapsed T'~ne: ~ min. Final fluid depth 54/0 in. Absorption rate >= 450 g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes. give date D. UFT STATION Date installed. NA 'Pump on' level at in. Datum E. SEPARA'nON DISTANCES Size in gallons 'Pump cfr level at Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lilt stat]on on lot NA Absorption field on lot NA Public sewer main NA Sewerlsspflcsenace line NA In. Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements?, in. On adjacem lots NA On adjacent lots NA Public sewer manhote/cleanout NA Holding tank NA SEPARATION DISTANCES FROM SEFTIC/HOLDING TANK ON LOT TO: At:)~q:)tlon field 5+ Surface water 100+ Building foundation 5+ Property line 45 Water main 60+ Water sewice line 10" Walls on adjacent lots 200+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation Sudace water 100+ Walls on adjacent lots 200+ Prope~/line 2 Water Sewtce line 10" Curtain drain None known F. COMMENI~ Water main 25+ Driveway, paridngfvehic~e storage 2 '2001 b'lmch, tea_t_~. Indh,"idualty. Ot~ flek:l dl~. *'Per ~/01 HAA by T. I~, P.E. Exact ~.~.~nown, , ............. ENGINEER S CERTIFICATION review of Municipal reconla that t/~e above s~ema conformance ~ MOA HAA guicle//nes Jn effect on Engineer's Printed Name Cindy W. Ellis ~..... cE.,,,, ...~/ H,~ Fee $ /-1'~0 .b-~ Waiver Fee $ Date of Payment Receipt Number (Rev. 12J01 ) Date of Payment Receipt Numt)er BBB / / / / / / / / / / / / / / / L = I c~1D.5:3 / / / / / / / / / / / / / / / / / / / / / / / / / I HEREBY CERTIFY THAT I HAVE ~RFORMED A MORTGAGEE'S INSPeCTiON OF THE FO%LOWING ANCHORAGE RECORDING DiSTRiCT, ALASKA AND THAT THE VISIBLE Ik, IF'ROVEMENTS SITUATED THEREOH ARE WiTVdN I'HE pROPeRTY ~.INES AND NO VISISLE EHCROACItk4(NTS EXIST OTHER THAN NOTED. DATED AT *~ICCI40RAOE, ~J.A,S KA THIS _STH Municipality of Anchorage Development Services Department BuiIding Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us ~ (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING -' Parcel I.D. 1. GENERAL INFORMATION Complete legal description HAA# HA Expiration Date: Location (site address o~' ~irections) Cu~ent Prope~ owner(s) Mailing address Lending agen~ Mailing address Real Estate Agent Mailing Address Unless othe~ise mquested, H~ will be held by DSD for pickup. 2. NUMBEROF BEDROOMS: TYPE OF WATER SUPPLY: Individual Well [] Individual Water Storage [] Community Class ~A Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site I~] Individual Holding tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representaticns given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for propertles served by a private or Class C well and may be reissued with new water sample results less than 30 days eld. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by C=ass A or B wells or a public water system. The Municipality of Anchorage is not respcnsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage flies and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of insta,ation. NameofFirm /~l~ /-/c? ")'~,cA,~; c~./ .C~,';¢ ~ Phone Address Engineer's Printed Name '?"Aao,/o,-e ~.. ~.~'~,o,,"c Date DSD SIGNATURE · ~ Approved for. ~ . bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments ..... ~ ~ ON-SITE ~ ~, ~ : WAST~ATER Attachments: HAA Checklist Septic System Advisory Well Flow Advisory X Maintenance Agreements Supplemental Engineer's Report Other Odginal Certificate Date: ~" 7'" ~ / Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewatar Program 4700 South Bragaw St. P.O. Box 196650 Anchorage. AK 99519-66,50 www.ci.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST LegaIDesc~ipfion: ~-,of~ ~7~ ~/OC~[' /,~ ///~/; /,,/"~ ~$1~. I¥'~ ParcellD: O/.5' -/Z~' A. WELL DATA Weiltype ~lt~g.t' '~" IfA, B, orCprovidePWSID# '~/4::~'O$- WelILog(Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth ft. Cased to __fl. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. · ' Well production g.p.m, g.p.m. WATER SAMPLE RESULTS: Coliform __ colonies/100 mi. Nitrate ' ' mgJI. Other bacteria __ colonies/lO0 mi. Date of sample: e. SEPTIC/HOLDING TAN}( DATA Tank Type/Material ~'e/e ~'t. t/ .('Ff'~' [ Tank size ~OOO gal. Number of Comparlments Foundation deanout (Y/N) 7 Date of pumping '7 / 'ZO"//~ / Date installed Depression over tank (Y/N) Pumper C. ABSORPTION FIELD DATA ' ' Date installed (~ 15-/O ( Soil rating (g.p.d./~ o~ ~/bdrm) Length 5 ~ ft. Width 7. ~ Total depth t ~,~ ft. Date o¢ adequacy test Fluid depth in absorption field before test ~ in. Elapsed Time: __ min. Final fluid depth Any rejuvenation treatment (past 12 mo.) (Y/N & type) ft. Eft. absorption area ¥~'~-~ Monitoring tube __ tJ.,~. (,e~-.~.~ Results(Pass/Fail) ~ Water added ~ gal. in. Absorption rate >= System type Tr'e~c~ Gravel below pipe ~,&'~ ~ ~'~,,~4t. 9. t/' ~.~' Depression over field. For ~' bedrooms New depth in. · /,S"~2 g.p.d. If yes, give date ~. ~. O. UFT STATION Data installed Size in gallons 'Pump on" level at __ in. 'Pump off' level at __ in. Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: M. ~, 'Septic tanldlift station on lot ' , : .... Absorption field on lot Public sewer main Sewer/septic sewice line SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation Watar main ~ t~ Wells on adjacent lots Manhole/Access (Y/N) High water alarm level at Meets alan~ & circuit requirements? On .adjacent lets On adjacent lots Public sewer manhole/ctaanout Holding tank Property line */~" Absorption field ~'O'+ Water service line ~'- I0° Surface watar · IOO ' Water main SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line '~ ' ~. Building foundation ~'~'* Water Service line ~. lo * Curtain drain /qoe~' .,~'~',"~ Jn. Surface water ~, t¢~0 ' D~vey~a~. parking/vehicle storage Wells on adjacent lots Fo COMMENTS ~ I. of I~ ¢x.~¢~.¢/' O. ENGINEER'S CE~FI~ON I ce~ that I he~ de~in~ th~h fie~ i~ and review of Mun~ipal mc~s th~ the con.finance w~h MOA H~ gu~Snes in effe~ ~ this date. Engineer's Print~ Name H~AA Fee $ .'~ ~'0 ~"~' Waiver Fee $ Date of Payment ~ / 7/O I Date of Pa.ymeot ... Receipt Number ~ ~ ~ '7 ~ Receipt Number {Rev. 12/00) HUNIClPALITY OF ANCHORAGE DIVISION OF ENVIRO~'~IEI~AL HEAl,TH DEPAPJiT~ENT OF I'~-,ALTR AND EI~IR0~NTAL PROTECTION APPLICATI01' FOK }~.a. LTlt AUTHORITY APPROVAL CERTIFICtTE 1. General Information Application Da,e (a) Legal Description (include loC, block, subdivision,section, township, range) Location (address or directions) (b) Applicants Name ~-~ ~ v'~ Telephone Home Business Applicants Address ~ - ~ -- (c) Applican~ is (check one) Le~l~ Ins{i~u~ion ~; ~er/~r ~; Buyer ~; O~her ~ (~plain); ' ' (d) Lendin~ lns~itution Telephone Address (e) Real Estate Co. & Agent Address. Telephone (f) l~ail the HAA to the following address: 2. Type of Residence Single-Pamily~ Number of Bedrooms 3. Water Supply 'Individual Well~ Hulti-Family~ O:her ,(describe) No:e: If community well system, mus~ have ~rritten cor~irmation from the State Department of Environmental Conservation attesting to the le2ality and status. Sewage Disposal Onsite ~ Public ~--~ Communi~y ~ Holdin~ Tank ~-~ Note: If community well system, must have ~a:itten con~irmation from ~he S~ate Departmen~ o~ Environmental Conservation a~testing ~o ~he legality and s~a~us. [Page 1 of 2] Firm Providinz Inapections~ Tests~ File Search~ Data and Information As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investiiation of this Health Authority Approval show~ that the on-site water supply and/or waste~ater disposal system is safe, functional and adequate for the number of bedrooms and ~ype of structure indicated herein. I further verify that, based on the infor~ation obtained from the Hunicipality of Anchorage files and from my investigation --~ iupoctlon, the on-site water supply and/or wastewater disposal system is in compliance with all ~unieipal ..; State codes, ordinances, and regula- tions in effect on the, date of this ins~ction. Name of Fir Telephone. ? °3¢/A Address ~O'~' ~ /~ DItEP Approval Approved f~~. bedrooms Approve Disapproved Terms of C~nditional Approval CAUTION THE ~I~ICIPALITY OF ANCHORAGE DEPAR~[ENT OF ~TH ~ E~IRO~ ~OTECTION (DHEP) ISS~S ~TH A~HOKI~ ~OV~ ~KTIFICA~S B~ SO~LY U~N ~ ~P~SE~- ATIO~ ~VEN ~ P~ 5 ABO~ BY ~ INDEPE~E~ ~OFESSIO~L ENGX~ER ~XSTER~ IN ~ S~ OF ~S~. ~ ~EP ~ES ~ ~ A ~TESY TO P~C~SERS OF HO~S ~D T~Ig ~ING ~STI~IO~ ~ O~gg TO SATISFY ~S. ~PLO~ES OF ~EP ~ NOT ~UCT INSPECTIO~ O~ ~ALYZE ~TA BEFORE A ~RTIFICATE IS ISS~D. ~ ~ICIP~I~ OF ~CHO~ ~ NOT ~SPONSIB~ FOR ~0RS OK CHISSIO~ ~ ~ ~OFESSIO~L ENGI~ER*S ~O~K. (DHEP SEAL) I~A/eJ/DI8 [Page 2 of 2] 7 -19 oo A. ~ELL D~TA Well Classification ~.A~..% ~ Well Log P~essnt ,(Y/N) Tctal Depth Cased to Static Water Level Casing Height Above Ground Electrical Wiring in C~nduit (Y/N) Separation Distarmes f~cm Wall: To Septic/Holding Tank on Lot ~O~ ~' To Nearest Edge of Absocption Field on Lot To Nearest Public Sewer Lt~e Cleanout/Man~ole Water Sample Collected By Water Sample Test Hesults /~4UNICIPAL~ OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMfNTAL PROTECT/ON .UNZCZP. ZTY mo ) APR 1 0 z..4 RECEIVED C~LI~ Legal Description: ~ ~7, ~ ~ V~LLI ~U~ ~1~; ~N~% ~ [~ A~ B~ ~ C~ D.E.C, ~d(Y~) ~ ~te ~le~d. Yield ~p~ of ~ti~ ~ ~t At Sanit~ ~al ~ ~si~ (Y~) ~essi~ ~nd ~l~ad (Y~) ; On Adjoining Lots ~o~ ; On Adjoining Lots To Nearest Public Sewer To Nearest Se~r Service Line on LOt Be .SEPTIC/HOLDING TANK D~TA Date IP~talled ~_~~ Size /e~ No. of C~,t~a~tm~nts ~'~ Star. pipes (Y/N) ~F Air-tight Caps (Y/N) ~/ Foundation Cleanout (Y/N) Depression over Tank (Y/N) N ~ate Last Pumped ~'~.~//, ~ -- C~t~ ,. t, ' PumpingA~aintenanee Contract, on File (Y/N)N/~ , fc~ '~?A Holding Ta~R High-Water Alarm .(Y/N) )q/~- Temporary Holding Tank Permit (~/N) Separation Distances f~c~ Septic/Holding Tank.' To Water-Supply Wall ~O ~ + To Building Foumdaticn To Property Line ~Fo 1~ To Dis[x~al Field '~O 1/ To Water Maip./Se~vioe Lir~ ~O {' To Stream, Pond, Lake, c~ Major Drainage Ccaments [Page 1 of 2] Receipt ~ Date Paid: Arno un t: 2-15-84 ABSORPTION FIELD DATA Soils ~ating in Abs_or~tion Strata Date Ir~talled Width of Field Length of Field Depth of Field '[ ~ Gravel Bed Thickness ~ate of Last ~d~quacy Test Square Feet of Abscrption Area Depression. over Field (Y/N) Results of fast Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well ~-~ 0 (' TO P~operty Line ~ ~ To Buildir~ Foundation ~ To Existing cr Abandoned System cn Lot ~--~ ; On Adjoining Lots ~O ;t To Wate~ Main/Service Li~ /O ~ . To Cutback(if present) ~ Q N ~ To Stream/Pond/Lake/(x Major Drainage Course i~O ~ ~- To Driveway, Pa~king Area, or Vehicle Storage Area ,,~ ~ Comments Date Immtalled Size in Gallo~.~ "Pump On" Level at High Water Alarm Level at Tested fog Electrical Codes(Y/N) Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA '* Check Permitted Bedrocm Rating Agair.~t HAA Bequest I certify that I have ~hecked, verified, or oo~fc~m~d to all MOA H;%% Guidelines in effect on the date of this inepecticn. Signed Cu~%~any KB1/d5/s ~OA No.&~T-o l[ [Page 2 of 2] . ,~ ./~.. 2-15-84 MARX ENTERPRISES, INCORPORATED ANCHORAGE CESSPOOL PUMPING Alaska Pumping P. O. Box 110232 ANCHORAGE, ALASKA 99511-0232 Ap~v~l 4, ~985 To wh~m it ~t concern= Thi6 ls £o c~L{~t tt~t A~ho~ge C~pool P~g p~ped the 6~st~ fo~ Rob~ Sp~z on Dec~b~ 5, 1984. If qo~ ~ve an~ Phone 344-2453 344-2632 IONMENTALCONSERVATiON ANCHORAGE/WESTERN DISTRICT OFFICE 437 "E" STREET, SUITE 303 ANCHORAGE, At~ASKA 99501 BILL SHEFFIELD,, COVERNOR Telephone: Addre~: 274-2533 To Whom it May Concern: According to records on file in this office the~~.y-~__~ ~' ater System is in compliance.with the State Drinking Water Regulations Sincerely, ~'~artmcnt of Envir-nmcntal Qualitf~' .'ater and Sewer Questionnaire Date , not . Questions: 1. }Iow many bedrooms.., are now in your house? ~/.- ~/va z~WA ~.~ 2. How many bedrooms were in the house at the time of purchase? 3. Were the basement bedroom walls "roughed in" at 'thc time of purehase?~ 4. Was the basement bathroom plumbing "roughed in" at the time of purchase? ~ _ ~t~8/~G ~bd~D I~ ~ ~W~ 5. Did the realtor or builder inform you that you would have to enlarge~he existing sewer system if you finished the basement bedroom (s)?. 6. If on a public water supply, do you ahvays have an adequate supply of water? j/~ ~ 7. Is the pressure always adequate? 8. Who was the builder? ~ 9. Who was the home purchased from?.~w OTtlER COMMENTS: