Loading...
HomeMy WebLinkAboutSHANGRI-LA LT 1Onsite File Shangri-la Lot 1 PID# 020-043-19 1997 permit was issued for Horace Tr 3A (now Lot 1). Unknown if anything was installed. Apr 06 06 02:00p Sonshine Enterprises (5071 346-6057 p.3 Municipality of Anchorage Department of Health and Human Services 825'L' Street P.O. Box 196650 Anchorage, Alaska 99519-6650 �-' Rick Nystrom hhww p:ltw.a anchorage.ak us Mayor Permit Number: #SW 040018 Date of Issue: 2-13-03 Parcel Identification Number: 020-043-19 Date Started: 2-20-04 Date Completed: 2-21-04 Is well located at approved permit location? ® Yes ❑ No Legal Description: Shanori-Le Estates Lot 1 Property Owner Name & Address: Anchorage Development & Construction 9441 Abbott Loop Road ❑ Open End ® Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Stan feet Stopped feet IFGrout Type: bentonite granules Volume: 3 Depth: Start 0 feet Stopped 33 feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: chlorine tablets Comments: Well Driller. Alpine Drilling & Enterprises PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property AnCnorann stlaSKa VVOUr Borehole Data: Soil Type, Thickness & Water Strata Depth (ft) From To Method of Drilling ® air rotary ❑ cable tool Casing type: steel stick-up gravelly silt silty cobbly gravel gravelly silt 0 2 10 22 2 10 22 28 Wall Thickness:.250 inches Diameter: 6 inches Depth: 33 feet Liner Type: Diameter: inches Depth: feet Casing stickup above ground: 2 feet bedrock 28 300 Static water level (from ground level): 33 feet Pumping level: 300 feet after 2 hours pumping 8 gpm Recovery Rate: 8 gpm Method of Testing: air lift Well Intake Opening Type: ❑ Open End ® Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Stan feet Stopped feet IFGrout Type: bentonite granules Volume: 3 Depth: Start 0 feet Stopped 33 feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: chlorine tablets Comments: Well Driller. Alpine Drilling & Enterprises PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property MUNICIPALITY OF ANCHORAGE Development Services Department Onsite Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Permit Number: SW040018 Legal Description: Shangri-La Estates Lot 1 Design Engineer: 0000 None Required Owner Name: Anchorage Development & Construction Owner Address: 9441 Abbott Loop Road Anchorage , AK 99507 - Date Issued: Feb 13, 2004 Expiration Date: Feb 12, 2005 Parcel ID: 020-043-19 Site Address: Unknown Lot Size: 41854 SO. FT. Total Bedrooms: 0 Permit Bedrooms: 0 This permit is for the construction of. ❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By. Date: c;�— / 7_62y Date: ?_113101L Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWERMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 0 2 d — D 9 - /63 — 000 /e/ Permit NumberSW0¢00/8 Property owners) lq-�JC- 1b CV 4-60/1 *%' Day phone 3LI67 2,/L/7 Mailing address (1 LfC%l Mailing address (2) 6k1rUC U, (3,- Zip Code (i9 54 7` Legal description (Lot, Block & Sub'd.) LCAT I S/lQi t4/' / La 6572ar Legal description (Section, Township & Range) Lot Size `rt' C5'Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms Sewer Only ❑ Well Only X Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ 17:[I�3•� L77�i�'Ldi7�EilI`i.1� Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and Is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) G Permit Fees: 7 s a Waiver Fees: Date of Payment: // /U Q Date of Payment: Receipt Number: 04 0 U / 3 Receipt Number: (Rev. 12100) I� r. WEI SIMS; r�� I �• I oil 1!k dfRQ _ • � • ,, ■ � 1 I� r. WEI SIMS; r�� I Rick Mystrom, Mayor Mtmic pality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 http://www.cLanchorage.ak.us 343-4744 August 12, 1998 Larry E & Elaine B Williamson PO Box 190392 Anchorage, Alaska 99519 0392 Subject: Tract 3A Horace Subdivision Permit #SW970253, PID #020-043-11 The subject permit, issued August 12, 1997 by this office for a single family well and/or on-site wastewater system, has expired as of August 12, 1998. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. tf you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. Ail inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. Sincerer lY' ~/~ lam~s Cross, P.E. Pro.am Manager On-site Services enc: Copy of Permit cc: Steven R. Pannone, P.E. PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970253 DESIGN ENGINEER:STEVEN R. PANNONE OWNER NAME:WILLIkMSON LARRY E & ELAINE B OWNER ADDRESS:P.O.'BOX 190392 ANCHORAGE, ALASKA 99516-0392 DATE ISSUED: 8/12/97 EXPIRATION DATE: 8/12/98 PARCEL ID:02004311 LEGAL DESCRIPTION: LOT SIZE: 435600 (SQ. FT.) NUMBER OF BEDROOMS: 2 THIS PERMIT: THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASICA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (ISAAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS RECEIVED B :y~__ ~~--~ DATE: DATE: Steven R. Pannone, P.E. Consulting Engineer (907) 272-8218 P.O. Box 142025 Anchorage, Alaska, 99514 (907)272-8218 Fax July 27, 1997 Municipality of Anchorage Dept. of Health & Human Services On-Site Services Section P. O. Box 196650 Anchorage, Alaska 99519 Subject: Tract 3A Horace Subdivision Well and Septic Permit Gentlemen: My firm was contacted to investigate the possibility of installing of a new system at the above referenced property. Currently the lot is undeveloped. A single test holes were excavated on July 21, 1997. The soil report and percolation test results are attached. Ground water was monitored for seven days. No ground water or bed rock was encountered or monitored. The lot is approximately 10 acres in size. Tract 3A slopes to the northwest at a rate of approximately 1 to 2 percent The proposed installation will be located on the northern portion of the lot. The proposed location will be greater than 100 feet away from the proposed well serving this property and 25 feet from the water service lines. The surrounding systems are located greater than 150 feet from the proposed installation, the lots to the north, south and east are undeveloped. The proposed installation shall not impact the future development of the surrounding or existing lots. See attached design. If you have any questions about the proposed installation, please contact me at 272-8218 Sincerely, teven R. Pannone, P.E. Attachments: '1 DESIGN ~A~TE~tATER ABSF1RPTIFIN ~YSTEM ~/~ TRACT 3A, HDRACE SUBD, LOT 81~ m m LOT 8n ~ UNSUB~IVt3E3 TRACT 3~ UNDEVELOPED TRACT 1 UN~EVELDPE~ DESIGN' Pert R~e = 1,5 MIn/Inch Soils= 125 s~/br - 3 Bedroom House 375 ~F Rqd ..... ~ 3esign, ~ep~h, ~ ~ ~ Dr~wlno C,~orkN3AHDRA,DVG ..... . ' ....................... ~' "~ P:nnone Eng. ~'~"~'R. Ponnone~'~. PREPARE9 FOR. · 2~-%_~.~,.. CE~ B149 .-$~' L:rry & E[:ln WllU~mson P. O, 9OX 142025 e~-.. ~ .-'Lo-- ANCHORAGE, ALASKA 99514 '*g~ ~ ............ ~ AncHorage, AK 99505 272-8218, PHONE & FAX LDT ~ bi-,. ~ ~,0 LOT nhJ L3T LOT 8 ~LDCK 3 EXISTING ;dELL I:'XlSTING o ;dELL 13 DESIGN WASTEWATER ABS[]RPTIDN SYSTEM TRACT gA, HORACE SUBD, UNgU~DIVIDED -- 10' TELE & ELECT, EASEMENT RESERVE ~Y~TEM LOCATAION UNDEVELOPED ND VELL DR SEPTIC SYSTEMS V/IN 200' OF PROPOSED SYSTEM ELECTRIC EASEMENT PROPOSED WELL PROPDSE~ NEW SYSTEM 5' EFF, TRENCH, 40 LF PRDPDSEiO NEV 1,00§g SEPTIC TANK ~R HOUSE\XXx'~'-[~ EXISTING E DR HOUSE TO ~E RELOCATE9 UNDEVELOPED NO WELL OR SEPTIC SYSTENS U/IN EO0' DF PROPOSE9 SYSTEH UNDEVELOPED ND WELL DR SEPTIC SYSTEMS V/IN ~00' DF PROPOSED SYSTEH TRACT 3~ UNDEVELOPED Pert Ra~ce = 1,5 Mln/Inch Soils= 125 s?/Ior 3 Bedroom House 375 SF Rqd Design, 5' E+'?ec~clve, 8' To~c~[ Dep~ch, 40 LF To~c~[ Absorp~clon = 400 s~ PREPARED FDR~ l~rry & Elaln Wllll~mson Anchor~@e, AK 99505 (907) 243-5354 PANNDNE ENG. SVC P. D, BOX 142025 ANCHORAGE, ALASKA 99514 274-~3~8, 272-8218 F~x ~AT£, 7-30-97 I DESIGN ~CALEI I PRDPDSE~ RELOCATE~ E ~R HOUSE ~/OARA~E TCQ TCD DESIGN DETAILS WASTEWATER A]~SDRPTION SYSTEN TRACT 3A, HDRACE SUBD, PRDPBSEO NEW SYSTEM ....------'"""-- 5' EFF, TRENCH, 40 LF 8' TOTAL 9EPTH NT PRDPDSE~ NEV 9C0_./ 1,000g SEPTIC TANK ~Q N¥390 3~N~ ~D~INOW INSTALLATIDN PLAN SCALE 1,30 1fid NV393 ~flO NV3'"O ~flDNV393 J.NO 1~39~ ]~ro, wlnO Ct\~/ork\3AHORA,n~/G ~nO N4~393 NI]IJVIINflD3 PREPARED FOR, Larry & Elaln WllllaMsOn Anchorage, AK 99505 (907) 243-5354 Pannone Eng, Svc, P, 0, BDX 142025 ANCHDRAGE, ALASKA 99514 872-8818, PHONE & FAX DATE, 7'30-97 I AS-NDTED DESIGN Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LA}~-/"~'¥'' ~r'~-//-/~l,4.J ~.,~t.f....Ct,~./~l...~/~) LEGAL DESCRIPTION: DATE PERFO~~ Township, Range, Section: 1 2 3- 4 5 6 7 8 9 10 11 12 13 14 15 16- 17- 18- 19- 2O SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? N __"%_ ~ rv S L IF YES, AT WHAT .... O DEPTH? p E Depth lo Water Alter , Date. ~,-/~"--//~;7.7.7.7.7.7.7.7~. Monitoring? '"'j~ ('~,"T' .__ Reading Date Gross Net Depth to Net Time Time Water Drop &::si I E~ ~ : q ~ t 5 qc, ~/q PERCOLATION RATE ~/~,~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~:~ FT AND ~ FT PERFORMED BY: ~ '~'~;~:),ak~J~/(~)~J &-~ _~, E.. I ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES iN EFFECT ON THIS DATE, DATE: :~;Z./~ ~/~