Loading...
HomeMy WebLinkAboutTERI #2 TR BTeri #2 Tract B 050-751-23 EXPIRED PERMIT June 1, 2004 Munieipality of Anehorage Mark Begich, Mayor Builtlin(l Safety Division F.O. Box 196650 • 4700 Bragaw Street Anchorage, Alaska 99519-6650 • (907) 333.8301• Fax (907) 333.8200 littp://m-%w.muni.org Nes & Pam Mooty 19000 Crystal Island Drive Eagle River, AK 99577 Subject: On -Site Nater and/or Wastewater Permit. Permit Number: SW030226 Legal Description:TFoff#2:TractB7? Dear Mr. R. Mrs. Mooty: An On -Site Nater/Wastewater Permit, number SW030226, issued by this office for a single-family system, will expire on June 30, 2004 This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit for a second year may be issued for a fee of $115.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are: $460.00 for a wastewater permit and $175.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincerely, 2 XKXKz / . Daniel Roth Program Manager On -Site Nater and Wastewater Program Enc: Copy of permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 -? f k I -1 V 1`_V1 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Jun 27, 2003 Expiration Date: Jun 26, 2004 Permit Number: SW030226 Parcel ID: 050-751-23 Legal Description:fta #23 Design Engineer: 0070 KND Engineering Site Address: Unknown Owner Name: Wes & Pam Mooty Lot Size: 296034 SQ. FT. Owner Address: 19000 Crystal Island Drive Total Bedrooms: 4 Permit Bedrooms: 4 Eagle River, AK 99577 - This permit is for the construction of: Q Disposal Field ❑� Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by catling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. o �_ /(/e ilk b.r Yel* toe S 6 Ver 1170 rlrtl Well VG7� (Jr 6� n 1JS . 4/p Received By: Issued By. Con-ttc Jcw Date: ,2-713 !�/. Date: Municipality of Anchorage �'. Development Services Department Building Safety Division On -Site Water and Wastewater Program 44 4700 South Bragaw St. ` P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. O .S D - % -1— 2 3 PermitNumberm 0 30 2AL Property owner(s) Was & Pam Mooty Dayphone 694-5337 . .•. �r�111111171 :.. moil Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd ) Teri #2, Tract B Legal description (Section, Township & Range) Lot Size 3 cres/ q.Ft. THIS APPLICATION IS FOR: Number of Bedrooms Sewer Only ❑ Well Only ❑ Sewer and Well ® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. of property owner or authorized agent) Permit Fees: ,d.SC-D Waiver Fees: Date of Payment: D_/Z002 Date of Payment: Receipt Number: o376P09 Receipt Number: (Rev. 12100) K D ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER. AK 99577-8736 (907)696-8111 June 25, 2003 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: New sewer/well permit — Teri #2, Tract B Gentlemen: The owner has requested we proceed forward to obtain a septic permit on the subject lot. On May 14, 2003 two testholes were performed for the proposed system. The results of these tests are attached. The general slope of this lot is, from northeast to southwest at a grade of approximately 10-20%. We have designed our system utilizing the existing testholes that were excavated for the proposed 4 -bedroom house. The lot will be served by an individual well, located on the east -central portion of the lot. We propose to install one 5' wide shallow trench. Water was encountered during the excavation at 11' and during monitoring at 9'. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, ENID Engineering, Inc. Kenneth M. Duffus, P Attachments: On -Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test Contractor/Owner Specs WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLA 4K, U ■ TERI SUBD. #2, TRACT B NO PNLTC WELLS WITHIN Yar IF PROPOSED SYSTEM TO PRIVATE WELLS WITHIN BDr Or PROPOSED SYSTEM EXCEPT AS NOTED. NO SEPTIC SYSTEMS WITHIN ROD' OE PROPOSED WELL EXCEPT AS NOTED. AO%' FTSSIO0, Ar DESIGN DETAILS 4 BDRM X 150 GPD - 600 GPD 600 GPD/0.8 GPD PER SQ. FT. (3.6 MIN/IN.>= 750 SQ. FT (750/5'(W)) X .64(RF) (2.5' GRAVEL) = 96.0 FT. TRENCH USE I TRENCH - 96 (L) X 5' (W) X 2.5'(D) Total depth of system Is 4.5' from original grade. Total depth of gravel below distribution pipe Is 2.5' . NOTES: 1. USE 1250 GALLON SEPTIC TANK, INSULATE IF <4' OF COVER. 2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM. 3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK. 4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN. 3' COVER IF REQUIRED. 5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS, SEPTICS, LOT LINES, FOUNDATIONS AND ALL OTHER SETBACKS. PREPARED FOR: WES 6 PAM MOOTY 19000 CRYSTAL IS. DR. EAGLE RIVER, AK. 99577 (907) 694-5337 FIELD BOOKS I ONSWTm. tMr. tIA DRAPN: ST— NA a1EOIM. ASBtRT. NA DATE: 0R6 nr. SmO: Am F` 03012.DWGI JOB No: 03012 Scale: 1'= 100' PAGE 1 OF 2 ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 11 WASTEWATER DISPOSAL TERI SUBD. #2, ,100 03-1 'yam D MT 96' A -2 Aar r o;� OF• ALq Si 1 of ... .... ............ G CE 7116 a 'moo•••.. ....••'�'/ \ %prSS1oll" A 57' SYSTEM TRACT B 10' PREPARED FOR, WES & PAM MOOTY 19000 CRYSTAL IS. DR. EAGLE RIVER, AK. 99577 (907) 694-5337 Z FIELD BOOKS Ca TED: DOUMDMY: N A DRAW: STA"OQ NA OiCdf@ KMQ •mMr: A DAR 4 M 11b pe° SE704 A' 118 03012.DWG '°B N' 03012 DETAILS w 38' PROPOSED 1250 GAL TANK 15' Scale: 1'= 20' PAGE 2 OF 2 1 J M.L11W ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX 907)696-8111 KND ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 SOILS PERCOLATION TEST �E•�FF A�.gsl1! •• E9L JI r CE 7116 cn ........... Performed for. Wes & Pam Mooty Date Performed: 5/14/03�� Project: Teri Add. #2. Tract B TEST HOLE # 03-2 Depth 14- 15- 16- 17- 18- 19- 20 - SEE ATTACHED SITE PLAN ORG/OL FOR HOLE LOCATION GP/SP w/ occ. gm/sm lenses, firm density, cobbles to 1' & boulder to 3' silt/moisture increasing w/ depth B.O.11. HOLE PRESOAKED PRIOR TO TEST Was Groundwater encountered? YES What depth? 12' Depth to water after monitoring? 9' Date? 5/21/03 Reading Date Gross Time Net Time Depth to Water Net Drop 1 5/14/03 1:00 6" - 2 1:10 10 min 213/16" 33/16" 3 1:11 6" - 4 1:21 10 min 215/16" 31/16" 5 • 1:22 - 6- 6 1:32 10 min 3" 3" 7 1:33 6" - 8 1:43 10 min 32/16" 214/16" 9 • 1:44 6" - 10 1:54 10 min 32/16" 214/16" 11 • 1:55 6" 1 - 12 2:05 1 10 min 33/16" 213/16" " Water Added Percolation Rate 3.60 (min/in) Pere Hole Diameter 6" Test Run Between 4.5 feet and 5.5 feet 1, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. 'MD ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 SOILS PERCOLATION TEST Performed for. Wes & Pam Mooty Date Project: Teri Add. #2. Tract B TEST HOLE # 03-1 Depth (Feet) SEE ATTACHED SITE PLAN ORG/Ot FOR HOLE LOCATION GP/SP w/ occ. gm/sm lenses, firm density, cobbles to 1' silt/moisture increasing w/ depth B.O.11. 14- 15- 16- 17- 18- 19 - HOLE PRESOAKED 20- PRIOR TO TEST Was Groundwater encountered? YES What depth? 11' Depth to water after monitoring? 9.2' Date? 5/21/03 Reading Date Gross Time Net Time Depth to Water Net Drop 1 5/14/03 1:00 9" - 2 1:10 10 min dry 9" 3 1:11 - 9" - 4 1:21 10 min dry 9" 5 • 1:22 9" - 6 1:32 10 min 3/16" 813/16" 7 1:33 9" - 8 1:43 10 min 4/16" 812/16" 9 1:44 - 9" - 10 1:54 10 min 3/16" 8 13/16" 11 1:55 9" - 12 2:05 10 min 3/16" 813/16" • Water Added Percolation Rate 1.14 (min/in) Perc Hole Diameter 6" Test Run Between 4 feet and 5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. K D ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907) 696-6111/FAX (907) 696-8111 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES AND MATERIAL SPECIFICATIONS LEGAL DESCRIPTION: Teri #2, Tract B GENERAL: 1. The scope of this project includes the installation of aseptic tank and/or drainfield to serve a sine sco mil residence on the referenced property as delineated on the attached Municipality of Anchorage MOA) permit and site plan. 2. Construction shall be in accordance with the approved site plan and design drawings; MOA permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. K Engineering, Inc (KND) assumes no responsibility of the accuracy of the as -built survey .provided by the owner or owner's representative. 4. The owner or contractor is responsible to notify the engineer of any discrepancies noted on the design plans or drawings prior to commencing work. These discrepancies could be, but not limited to, possible encroachments, surface water, varying soils, unplatted easements, types or use of dwellings on or adjacent to property, nearby public wells, etc. 5. The contractor shall be responsible for locating any necessary underground utilities, easements, property lines and surface water. The owner and/or contractor shall ensure, if deemed appropriate, that a registered land surveyor prior to construction flags all setbacks. 6. The contractor shall be responsible for verifying all pertinent separation distances and component layout. 7. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. 8. The MOA Development Services Department On -Site Water & Wastewater Program must certify contractors installing wastewater disposal systems. Owners installing their own systems must also receive prior approval from said MOA Department. SEPTIC TANK / HOLDING TANK / LIFT STATION INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded with proper material and compacting to prevent damaging, settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above the final grade. 4. Septic tanks installed with less than 4 foot of cover shall be insulated. The contractor will ensure that the fill over the tank does not exceed the burial depth rating. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These eleanouts shall be located on undisturbed soil not more than 10 feet from the tank. The second cleanout, in line, shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. Page 1 of 3 Reference: Teri #2, Tr. B Date: 06125/03 Page: 2 of 3 7. All H.D.P.E. tanks shall have a vertical length of 4 -inch perforated drainpipe besides the tank extending to the bottom of the tank to above grade to monitor ground water. 8. All tanks shall be anchored when there is not enough adequate soil cover to resist buoyancy forces in high -groundwater areas. 9. All holding tanks and lift stations shall have an audible and visual alarm inside the residence. 10. All lift stations shall be wired in compliance with the Uniform Electrical Code and all MOA guidelines. 11. The contractor shall remove the old tank, or abandon it in compliance with the Uniform Plumbing Code. The contractor is solely responsible for the abandonment procedure. ABSORPTION TRENCII/DRAINFIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavaction become smeared, they must be raked or scratched (roughed -up) before gravel (sewer rock) placement. 2. Once the sewer rock is installed, the distribution pipe is installed level with the perforations facing downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. , Monitoring tubes shall be four- (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. 6. All advanced technology waste water disposal systems (Advantex, Biocycle, Intermittent Dosing Sand Filter, etc...) shall be constructed, installed, maintained and monitored per manufacturer's specifications and MOA requirements. MINIMUM MATERIAL SPECIFICATIONS: 1. A MOA approved septic tank manufacturer must construct any septic tank proposed for installation. 2. The following pipe materials are MOA approved for use in septic system installations: of Pine Perforate Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. If deemed necessary, a sieve analysis should be performed. 7. When sand is being used as a filter material, its gradation specification must conform to current MOA or DEC requirements. Reference: Teri N2, Tr. B Date: 06125/03 Page: 3 of 3 INSPECTIONS: Typically there will be three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the sewer rock, distribution lines, standpipes, and cleanouts, but before the placement of the silt barrier, insulation, or any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required, especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. The inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre -construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's activities. The owner shall contract with the contractor to perform the work outlined in these specifications and attached plans and in accordance with the attached MOA permit. All materials, components, and construction practices shall comply with the MOA's and the State of Alaska's latest ordinances, regulations, or policies regarding wells and septic systems. The failure of the inspecting engineer to notice a material or construction non-compliance does not relieve the contractor of his/her responsibility to correct such deficiency. There will be no contractual arrangement existing between the contractor and KND Engineering, Inc. KND shall be the owner's representative and will inspect the work as stated above to document the contractor's activities. Final acceptance of the contractor's work rests with the owner and the MOA. KND shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. KND's inspecting engineer will not be responsible for the construction means, methods, and techniques, sequence, procedures or the safety precautions incident to this project. BY PROCEEDING FORWARD WITH THE INSTALLATION OF THE WATER AND/OR WASTEWATER SYSTEM (S), THE PROPERTY OWNER, CONTRACTOR, AND WELL DRILLER ACKNOWLEDGES HAVING READ AND ACCEPTED THESE SPECIFICATIONS. Owner: Driller: Contractor: