THE TABLELANDS BLK 4 LT 1
The Tablelands Block 4 Lot 1 #051-811-58 Municipality of Anchorage Page 1 of 3 Development Services Department On-site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 9951"650 www ci.anchorage.ak.us (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO50095 PID Number. 051.811-58 Wastewater System: New rpinell Homes S i 1900 W. Northern Lights, Ste. 200 Anch. AK 99517 ABSORPTION FIELD Phaw mx'*aBa6O0n" 5'WideTrench 341.5678 Five 5 SW aaup iot" Davth wan aqm" peas LEGAL DESCRIPTION .8 GPDrrts 6 Ft. Bork la SLA)O.n: DSPM n PW Eaton Ban ongrrl peas Cnrat aeth aanasn P9• 4 4 1 The Tablelands 2 Ft. Ft TowntV Rrps Baapn Fa aaMO aEova wvr p•a• Gov" Lrpoi 94 2-3 Ft. Ft. Well: AWWU Water System 5 Ft. 2 10' cftald har fpr e. A, B. c). Taal Doth Cswa n oW tlaptr 940 Ft' ps ".w i ASTM 3034 PVC Ft. FL DnW eats onika 6ur,c W"a Ls Pisano's Dirtworks 6128.2912005 FL Y. PWVsa" W" A" (3001"0 TANK CPM Ft. FI SEPARATION DISTANCES Septic To Septic Absorption Lift Holding blrcJPrlvate Anchorage Tank 1,500 From Tank Field Station Tank Sewer Line v+aF >200' >200' NIA WA >25' a Steel Two (2) >100' >100' NIA NIA LIFT STATION — NONE ON LOT tout >5 >10' NIA NIA c" >5' >10' NIA NIA �P� in *87"a M Fo..n.nh n Pump MsMaAt Loa" lecncal nrPaaan• W-a Ey c~Do None I Noted Fee. BENCH MARK ow bplftter valve Placed to Assure Lven Flow. Finished Floor. 100.0 FL Engineer's Stamp Ck ...;.,Y4aIN �•#i Inspections performed by: T. Kimbrough Dates: 1" 612812005 ; . 49th 2n 612912005 •._....__...................... .... R50Y y, j ��fn�M•C�ULL C. AAOE. Department of Health and Human Services approval .�c NoCE-4,8I Ja Reviewed and approved by: Date: 3 - q- G' .440 i��• �F......ESSI r" '°'°) pan.....• Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage. AK 99519-655 - 343-7904 Permit Number SWO50095 On -Site Wastewater Disposal System or Well Inspection Report SV 96S 324' 81 164 267 62 279 295 Mt 644 607 M2 776 me M3 43e 266 W 21.7 Wr Cs we 707 CB 1 419 245' C7 12441 146 G I E. ANDERSON CE -4361 - H/SpC8G ejR �h1 � eIA,a SLAB yymnMt `\ C7 U \ fl M4 M2 C5 mP 0TH2 Nte© 0 Page 2 of 3 PID No. 051.811-58 S 8715'40-E 47.36' THE TABLELANDS SUBDIVISION LOT 1, BLOCK 4 40.000 S.F. PLAN AS -BUILT SCALE V - 50' Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number SW050095 88.29 88.53 THM U E Page 3 of 3 PID No. 051-811-58 «. n E U 92.34 ex Ile Fabrig Drnlnfleld Rock L4.18U S 77 0 S U 92.07 r 84.2 the Fnb Drnlnfleld Rock 4.23 84.32 PROFILE AS -BUILT Scole: NONE 92.04 X88.14 92.14 \88.69 49th9�1 .S i NIGIAEL E ANDERSON f ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX MEMORANDUM DATE: March 25, 2006 TO: Jeff Poet FROM: Mike Anderson, P.E. SUBJECT: Lot 1, Block 4, The Tablelands Subdivision Certificate of On -Site Systems Approval We have revised the As -Built Site Plan to include the edge of the bluff located south of the southerly absorption trench. The measured distance to the edge of the bluff from the edge of the absorption trench is 42'. The intersection of the 25% slope from 2.5' above the distribution pipe in the trench to the existing ground is 82.4' which exceeds the required 50' distance. We have also modified the location and type of the alternate system. It will now be an Advantex treatment system and located at the front of the lot and away from the bluff. A third test hole and percolation test was performed at the location of the alternate site. Copies of the revised Plan As -Built, Alternate Site Design, Slope Analysis, Test Hole No. 3 and a revised Profile As -Built, which includes the original test hole location and elevation are attached for your review. Please advise if you have further questions. W O N o O CD O :u^H. + 0 O 0 QJo N m O co -� Cf)D A �o ; W D D C) � r v + O J J o � -.L H- �11-m 0o D o,� - Z 0 mo Zco D in T4 Lo+ � O O � 00 >Z C C) C W Cn .p 0 C) < o O Z + 0 0 0 QJo MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION. LOT I BLOCK 4, THE TABLELANDS S/D PERFORMED FOR, SPINELL HOMES DATE: 3/23/2006 PROJECT No • M0512 PARCEL IDn• TECHNICIAN: T. L. KIMBROUGH nrPTTI TEST HOLE # 3 1 NET TIME (MINUTES) 2 Frast Encountered 3/23/od TEST HOLE PRESOAKED PRIOR TO TESTING: 4 $ DRY MEDIUM DENSE SILTY SAND W/GRAVEL CHARGE SP -SM 7 2 8 30 9 11 ---- WAS GROUND WATER ENCOUNTERED? No 10 IF YES ® WI IAT DFP71I� GM DEPTII OF WATER AFTER MONITORING: N W 11 WELL COMPACTED DATEOF MONITORING: 317 //7 0016 SILTY GRAVEL <5% >25 > DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH of WATER (INCHES) NET DROP (INCIIEs) 3/23/od TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1245 11.0' CHARGE 2 1315 30 8.325' 2.675' 3 1315 12,0' RECHARGE 4 1345 30 9.125' 2.875' $ 1345 12.0' RECHARGE 6 1415 30 1 9.375' 2.675' PERCOLATION RATE 11,_2 (MINANCII) FERC. HOLE DIA. 6 (INCHES) TEST RLN BETWEEN: 4,_5 FT. and 5_5 Ff. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITI I ALLSTATE AND MUNICIPLB GUIDELINES IN EFFECT ON THIS DATE - Permit Number. SWO50095 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Apr 25, 2005 Expiration Date: Apr 25, 2006 Parcel ID: 051-811-58 Legal Description: THE TABLELANDS SUBDIVISION BLOCK 4 LOT 1 Design Engineer: 0014 Anderson Engineering Owner Name: SPINELL HOMES, INC. Owner Address: 22700 WHISPERING BIRCH DRIVE PETERS CREEK. AK 99567 - Site Address: 22700 WHISPERING BIRCH DRIVE Lot Size: 40000 SO. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of. ❑✓ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By. Issued Date: Date: \ Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program' 4700 South Bragaw St. ` P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D.051-1MI-5? Permit Number SW Property owner(s)_Spinell Homes. Inc. Day phone 344.5678 Mailing address (1)1900 W. Northern Lights Blvd. Suite 200 Anchorage AK 99517 Mailing address (20?m Whispering Birch Drive Zip Code Legal description (Lot, Block & Sub'd.) Lot 1, Block 4. The Tablelands Subdivision Legal description (Section, Township & Range) Lot Size 40,000 SF Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms _Five (5) Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. A (Signature of property owner or authorized agent) r Permit Fees: Waiver Fees: Date of Payment: 5F- Zo — e r Date of Payment: Receipt Number: Receipt Number: (Rev. 12/00) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX April 20, 2005 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, Block 4, The Tablelands Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer. The owner of Lot 1, Block 4, The Tablelands Subdivision intends to construct a new five -bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is currently served by a community water system. No conflicts exist with adjacent septic systems or wells and the proposed septic system on this lot. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The current drainage pattern is identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Test holes recently placed on the lot indicated well graded to poorly graded sand and gravel with minor amounts of silt in the area of the absorption trench and alternate site. The accepting soils were tested and found to have a percolation rate of slightly more than 8 minutes per inch to 14 minutes per inch. The system is designed with an application rate of .8 GPD/SF. No groundwater was found in the test holes during placement and none was monitored during the ensuing period. Our design includes the placement of a new 1,500 -gallon septic tank along with 2 - 47' long and by 5' wide by 4' effective depth absorption trenches to collect and treat the sewage generated in the house. The bottom of the trenches will be 6' below the surface. The distribution pipe will be 2' below the surface. A flow splitter valve will be installed to insure even flow to each trench. A'minimum of 3' of cover will be placed atop the trenches and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at varying grades from north to south as shown on the Site Plan with steep slopes near the south end of the lot. The absorption trench will Lot 1, Block 4, The Tablelands Subdivision April 20, 2005 Page Two be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 4< 2004-25 THE TABLELANDS SUBDIVISION LOT 1, BLOCK 4 _ 40,000 S.F. as' S,, c.1363a F�Qj� c �e R•T68 \ �/ % $\\ !� \ 1,500 potion Fy Tank \ r ,pi eDtic MICHAEL E. ANDERSON SCALE V = 50' 50' 6 .10.15 Na \ CI " ®nn ®ra 5x \\ \\ % \ N 2 $ �7' Longe 5' 1Yde .ARem01e Site \\ \\ /S. w e 4' Ellec6re Depth P Absorption Trenches \ ro. \ 00 \ P taa-zcz \� \a •c \ x \ C o Ar, \\ \ \ 11 . I15%-25% \ \ 11 E 18S Oa N 7Tp7,36 40' S 87'15'40'E 47,59• xt%v, 10 .� •1 0 i SITE PLAN J" MICHAEL E. ANDERSON SCALE V = 50' 50' LOT 1, BLOCK 4, TABLELANDS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom House 5' Wide Trench System Perc. Rate: 8-14 Min./Inch 1,500 Gallon Septic Tank Application Rate: .8 GPD/SF 4' Drainfield Rock 5 Bedrooms X 150 GPDL8 GPD/SF (Application Rate) = 937.5 SF Absorption Area 937.5 SF/5 SF " .5 (Red. Factor) = 93.75 LF Trench Length THEREFORE: Construct 2-47' Long x 5' Wide x 4' Effective Depth Absorption Trenches. Flow Line Elevation in Trenches to be 2' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Trench. Provide Flow Splitter Valve to Insure Even Flow to Each Trench. 1'6" 1.5 4'0" Natural Backfill 3' Cover Over Trench Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Ca ,� Minimum 6' Separation From Bedrock. : 49th' " Minimum 4' Separation From Groundwater. • / Minimum 200' Separation From Wells in the Area.MICS LE MDERSo Minimum 10' Separation From Water Services. �0c�m No. cE.b, Minimum 100' Separation From Surface Water or Streams. �,�ke • •' '� MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT I, BLOCK L THE TA9LELANDS SID PERFORMED FOR, SPINELL HOMES DATE: L/II/2005 PROJECT No • M05I2 PARCEL ID#• TECHNICIAN: T. L. KIMBROUGH DEPTH TEST HOLE # 1 1 READING 03/OG SLOPi >25% 2 TEST HOLE PRESOAKED PRI1 3 1030 4 RGE_2 5 1100 30 <5% 6 3 7 I S -GM W/ GRAVELS R-ECHARGE 8 4 L)25' 9 9A25" 2.875' 10 I I 5 WAS GROUND WATER ENCOUNTERED? No IF YES Q WHAT DEPTH+ DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING :3 12.0' 13 BOH 14— is- 16- 17- 181 41516171s 19 SITE PLAN p I OTH2 SEE FUTURE ASBUILT <5% >25 DATE READING GROSS TIME (MINUTES) (MINUTES)HES) NET TIMEMTESTING: DROP 4/11/05 TEST HOLE PRESOAKED PRI1 1030 RGE_2 1100 30 75' 3 1100 12,0' R-ECHARGE 4 1130 30 9A25" 2.875' 5 1130 12.0' RECHARGE 61200 30 9.125' 2.875' PERCOLATION RATE• I�L_I (MIN/WCH) FERC. HOLE DIA. _6 JINCHES) TEST RUN BETWEEN: L_5 FT. and 5_5 Fr. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORME Al? IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: Z0_051 MUNICIPALITY OF ANCHORAGE • DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION• LOT I, BLOCK 4, THE TABLELANDS S/D PERFORMED FOR: SPINELL HOMES DATE: 4/II/2005 PROJECT No • M0512 PARCEL IDS' TECHNICIAN: T. L. KIMBROUGH DEPTH TEST HOLE # 2 (tett) OB/OG 2 JI 4 5 6 7 SI GMSANDS W/ GRAVELS s 9 t.m• lm II 14 15 16 17 18 19 SLOPE WAS GROUNDWATER ENCOUNTERED? No IF YES 9 WHAT DEPTH" DEPTH OF WATER AFTER MONITORING: NONE <50/a J<2 DATE OF MONITORLNG:�G DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) IDEP, ERF (INCHES) NET DRO? (INCHES) 4/11/05 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1040 12.0' CHARGE_ 2 1110 30 8.5' 3.5' 3 1110 12.0' RECHARGE 4 1140 30 8.5' 3.5' 5 1140 12.0' RECHARGE 6 1210 30 8.5' 3.5' PERCOLATION RATE; 8.6 (MN/NCH) PERC. HOLE DIA.(NCHES) TEST RUN BETWEEN: 4_5 FT, and 5_5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES EFFECT ON THIS DATE:_ Y- IN 'a O N s ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 1, BLOCK 4, TABLELANDS SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,500 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of two new 47' long X 5' wide X 4' effective depth absorption trenches at the location also shown on the Site Plan. The distribution line in the trenches will be placed at 2' below the existing ground surface. Total depth of the trenches will be 6' below the existing ground surface. A Zabel Flow Splitter Valve must be placed to insure even flow to each trench. A separation distance of 200' from any well and 100' between the septic tank and absorption trench and any surface water must also be maintained. A minimum of 3' of fill is required over the absorption trenches and 4' over the septic tank. In lieu of the required fill 2" of insulation and 2' of fill may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically. agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems. must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,500 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer, Construction shall include two 4" cleanouts for pumping access. Lot 1, Block 4, Tablelands April 20, 2005 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5: Contractor shall verify the septic tank and drainfield are a minimum 1 00'away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available.. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 1, Block 4, Tablelands April 20, 2005 Page 3 of 3 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. M MMUPQUTY O; A HCHORAGE Development Services Department" _7 Phone: 907-343-7904 On -Site Water & Wastewater Section - Fax: 907-343-7997 Parcel I.D. 051 811 58 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Complete legal description Expiration Date: 1 �Z_- :k& 2-0 THE TABLELANDS BLOCK 4 LOT 1 Location (site address) 22700 Whispering Birch Current property owner(s) Mailing address Real estate agent Heidkamp 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: �r Day phone Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑ Private Septic Fx_1 Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System 0 Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5rb Date of Payment 142g1lq Receipt Number ()7 �q6_7 � +Jay COSA # l 15c I q /&0 -I Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm C&M ENGINEERING Phone 8545558 Address 20182 TULWAR Engineer's Printed Name CHARLES BALZARINI Date 12/17/2019 OF s*.49TM *1 6. DSD SIGNATURE "' System #1 Approved for bedrooms ' ' ' ' ' ' ' ' ' ' ' ' .. CHARLES G BALZARIHI _�. • �`�i System #2 Approved for bedrooms �a ��'•, CE -13854 Aw Disapproved klj F' PROFESSIONP Conditional approval for bedrooms, with the following stipulations: .,,kk ttt((w/" vvti;; l EV 'TER By (� Original Certificate Date: ��f! The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA Checklist Legal Description: The Tablelands Block 4 Lot 1 Parcel ID: 051 811 58 If more than 1 septic system on lot: COSA Checklist # 1 of 1 Structure served by this system 1 A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments Public Water Supply B. TANK DATA Age of tank(s) 14 years Tank type/material steel ❑ Standpipes/foundation cleanout per record drawing Date of pumping 12/26/19 D. ABSORPTION FIELD DATA 2005 shallow trench Which system tested (date installed) 6/2005 ❑ ALL standpipes present per record drawing Total measured depth from grade 8 ft (max) Measured depth to pipe invert from grade 4 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of drainfield. If not, state depth into effective ❑ Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: All cleanouts verified as shown on inspection report. COSA Checklist yellow sheet Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date 12/16 Results ❑ Pass For 5 bedrooms Fluid depth prior to test 9 in Water added 750 gal New depth 15 in Elapsed time 1440 min Final fluid depth 9 in Absorption rate 750 gpd Any rejuvenation treatment (past 12 months) If yes, enter date na na E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ® Yes if No Community Sewer Manhole/Cleanout > 100' Driveway/Parking > 0' Yes if No ft if No D Yes if No ft Neighboring Tank > 100' F]Yes if No ft Private Sewer/Septic Line > 25' Yes if No ft Absorption Field on Lot > 100' F-1 Yes if No ft Holding Tank > 100' Yes if No ft Neighboring Absorption Fields > 100' ft Animal Containment > 50' Yes if No ft Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' F� Yes if No ft QYes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ® Yes if No ft Surface Water > 100' ®Yes if No ft Property Line > 5' QYes if No ft Driveway/Parking > 0' ® Yes if No, comment Absorption Field > 5' F4-1 Yes if No ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' Yes if No ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ®Yes if No ft From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ® Yes if No ft Driveway/Parking > 0' F41 Yes if No, comment Property Line > 10' ® Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0 Yes if No ft Private Wells > 100' ® Yes if No ft Water Service Line > 10' Q Yes if No ft Community Wells > 200' E] Yes if No ft Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION / certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. 12/1819 COSA Checklist yellow sheet _4�a�.s�g1d � ��TH — �� • �'. � ter CHARLES G BALZARIUI ,;eFG,/ , CE -13854 . ���®/® ���1 FapROfE6SIONP�'.®'g® NFrontier Surveys, LLC Project No: 19-505 Date:12/16/2019 0 Ordered By: Charles Balzarini Plat: 2004-25 Grid: N/A CULVERT C -- _ R o 02 h/�Ri�F �oV 0 PAVED DRIVEWAY by \ 14.9 SEE DETAIL a Cs, .0 . I5 1 2.0 p �5� ``. N � 0\ n 4.25' DECAGON SHED \ ie \ o'o 0 Lot 1, Block 4 \ LOT 2 The Tablelands Subdivision o 40,000 Sq. Ft. 22700 Whispering Birch Drive \ mem v \ I I 2 Story Wood Frame House z� \ W/Attached 3 Car Garage \ m NTy.0-7136"F 185.04 \ \ DETAIL: SCALE= 1 "=20' 15'40"E 47.59 N (V N 9.4 3.2 3.6 v 1.5 TRACT B " 5.8 vi .5 Electric Meter/Outside Power `Q� Telephone Pole O Metal Post Gas Meter ® Deck -0- Fence i#- Light Pole 13.6 1$; Sewer C/O (W; Water Well Q Mailbox Elec. Pedestal General Notes: 0 20 40 80 1. This document is created for the purpose of a single property transaction and is subject to Federal Copyright Laws. 2. Excepting for gross negligence, the liability for this survey shall not exceed the cost of preparing this survey. Scale 1f1 Feet 3. All measurements/setbacks are to the visuallapparent building footprint. 4. All dimensions to property lines are plus/minus 0.1 ft. [) F This survey complies with the ASPLS Mortgage Location Standards. The survey represents visible improvements and A11 11 !! conditions at the time of the survey. This document does not constitute a boundary survey and is subject to any inaccuracies . , q Z" �Q' •' • • `r/r- �/ that a subsequent boundary survey may reveal. It is the responsibility of the Owner to determine the existence of any easements, covenants, or restriction which do no appear on the Under record plat. no circumstances should this document be used for construction or for establishing a boundary or fence line. �P9 TH j As -Built Survey of: � 1h Lot 1, Block 4 The Tablelands Subdivision ................... F •, Frederic W. CA: �� FC •, N0. L9: 9946 I, Frederic Wagner, hereby certify that this Mortgage Inspection Survey was performed by me, or 12/17/2019 �`= under my direct supervision on December 16th, 2019. r1ff1;0,0 ESSIONA �P�O`~ Frontier Surveys, LLC FRONTIER, 650 W. 58th Ave. Suite E'Anchorage, Alaska 99518 Surveys•.," 907.460.1686 - info@frontiersurveys.com PROFESSIONAL SEAL www.frontiersurveys.com k *(wt,d� Municipality of Anchorage • Development Services Department ' Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519.6650 www.muni.org/onske (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-011-58 COSA If O G O 1. GENERAL INFORMATION Expiration Date: 3 – r— Complete legal description Lot 1, Blom 4, The Tablelands suhdWon Location (site address) Eo0 Wh'sPedng Bych Drive, Peters Geek AK 99567 Current Property owner(s) Spinell Homes, Inc. Day phone 344-5678 Mailing address 1900 W. Northam Lights Blvd.. Suite 200 Anchorage, AK 99517 Lending agency __ _ ___ Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD forpickup. 2. NUMBER OF BEDROOMS: Five (5) 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site R1 Individual Water Storage ❑ Individual Holding Tank ❑ Community Class A Well © Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given In paragraph 4 by an Independent professional civil engineer registered In the State of Alaska. Certificates of Onsite Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineers work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined in the Certificate of Onsite Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system Is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the Information obtained from the Municipality of Anchorage files and from my Investigation and Inspection, the on-site water supply and/or wastewater disposal system is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations In effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7n3 Address P.O. Box 240773 Anchorage. AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE Approved for bedrooms. Disapproved. Date =7=6 Conditional approvaLfof__-Jbedrooms, with the following stipulations. Attachments: COSA Checklist _X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: Original Certificate Date: 3 0 6 (RWAIM) Municipality of Anchorage • Development Services Department Building Safety Division Onsite Water & Wastewater Program 4700 8regaw Street P.O. Box 198850 Anchorage. AK 9951M50 www.muni.org/onske (907) 343.7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal DeScriptIon: Ld 1, abtic 4, The TabWands &rbAul m Parcel ID: 051-011.68 A. WELL DATA wen type - If A, B, or C provide PWSID a _ WON Log (YIN) Date completed _ Sanitary seat (YIN) _ Wires properly protected (YIN) Total depth R Cased to R. Casing height (above ground) in. FROM WELL LOO AT INSPECTION Date of test Static water level Well production g.p.m. 9 -p.m - WATER SAMPLE RESULTS: Colffomn colonles/100 mL Nitrate mglL Other bacteria colonies/100 mL Arsenic _ mgn Date of sample: _ Collected by: B. SEPTICIHOLDING TANK DATA Tank TypeAdaterlal sm"Spnrc Date installed W2MM Tank size 1AW gal. Number of Compartments? Cleanouts (Y/N) Y Foundetlon cleanout (Y" Y Depression over tank (YIN) N High water alarm (YM) N Date of pumping Now C=WU0m Pumper C. ABSORPTION FIELD DATA Vete Installed 6/1BMM SON rating (g.p.ddle or fe/bdnn).8 OPDISF System type s Wee Trench Length 84 R Width 5 R. Gravel below pipe 4 R. Total depth _1__A Efl: absorption area s4o tl' Monitoring tube Y Depression over field N Date of adequacy test Results (Pass/Felq For _ bedrooms Fluid depth in absorption field before test In. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >- g.p.d. Any rejuvenation treatrnent (past 12 mo.) (YIN & type) If yes. give date i D. LIFT STATION Date installed She in gallons 'Pump on' level at _ in. 'Pump ofi' level at _ in. Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAilt station on lot Manhole/Access (YM) High water alarm level at in. Meets alamr 6 circuit req *kern ts9 On adjacent Iota Absorption Held on lot On adjacent lots Public sewer main Sewer /septic service one Public sewer menhoWdeanout Holding tank Animal containment areas Manure/anknai exaete storage areas SEPARATION DISTANCES FROM SEPTICOHOLDING TANK ON LOT TO: Building foundation >6 Property Ane>s Absorption field >s Water mein WA Water service line >td Surface water >1W Wells on adjacent lots >= SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property Una >lo' Building foundation >tiy Water main WA Water Service line >ta Surface water >toa Driveway. peddteNenids stmape ,py r Curtain drain None moored Wells on adjacent kxs7 DO 31 F. COMMENTS: P"y Isserved by Awwu water system. 0. ENGINEER'S CERTIFICATION I Cerffly that 1 have detem*ied though /laid inspections and review of Municipal records that the above systema ars in CankMance with MOA COSA guiddlinGS in effect on this date. Engineer's Printed Name Mmheel E. Andersm P.E. Date 7J27r2ooe COSA Fee i EAD Waiver Fes $ Date of Payment WMAN Receipt Number 77C iRev. tiros► � r� , o __ 49th L Date of Payment Receipt Number. _ 7 2004-25 THE TABLELANDS SUBDIVISION LOT 1, BLOCK 4 40,000 S.F. -WH/s'°fR/ 156.s2. o � � I 15.2' "= 40' AS -BUILT GASTALDI LAND SURVEYING, LLC JEFF A. GASTALDI, R.L.S. 4726 WEST 88TH AVENUE ANCHORAGE, ALASKA 99502 PHONE 248-5454 GRID DATE NW 1559 12/28/2005 F.B. JOB NO. 05-16 1 TLS14 EXISTING BUILDING 47 •OO. \ \\ S ' So" SYSTEM I HEREBY CERTIFY THAT I HAVE SURVEYED THE PROPERTY DEPICTED ABOVE AND THAT NO ENCROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS WHICH DO NOT APPEAR ON .THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES. ANCHORAGE RECORDING DISTRICT, ALASKA NOTE: NO CORNERS SET THIS DATE OF A4 P�•••••.....�•�..• sem. CO .... ......N v JfN.ry0. Caftaid, - ° •�� A�O��f flonol ��.��•