HomeMy WebLinkAboutTHE TABLELANDS BLK 4 LT 8AMunicipality of Anchorage On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP241045 PID Number: 051-801-72 Dwelling: RN Single Family (SF) El with ADU [:1 Duplex (D) El Two Single Family Project: R New RE Upgrade Name Scott Boone ABSORPTION FIELD R Deep Trench RN Wide Trench El Bed R Mound Site Address 23006 Whispering Birch Drive EJ Other Phone Number of Bedrooms Soil Rating depth from original grade (907) 244-0769 4 0.45 GPD/SF JTotal 8.9 / 8.9 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.9/4.9 Ft. Gravel depth beneath pipe 4.0/4.0 Ft. Subdivision Block Lot The Tablelands 4 8A Fill added above original grade 0.2/0.3 Ft. Gravel length 67 / 67 Ft. Township Range Section Gravel width 5/5 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches 2 Dist. between trenches 8 From Tank Field Tank Line 1,340 Ft2 Ft. Well >100' >1 00' N/A N/A >25 TANK Fm] Septic [] S.T.E.P. El Holding El Other Manufacturer Greer Capacity 1250 Gal. Surface Water >1 00' >100' N/A N/A Material Plastic Number of compartments 2 Lot Line >5' >10' N/A N/A NA Foundation >10' >10' N/A N/A LIFT STATION IMan er Capacity Gal. Remarks Trenches listed East / West Alarm location I installed by PIPE MATERIAL House to tank D3034 drainfieldTankto D3034 Installer A. C. E. S. Drainfield D3034 CO/MT D3034 Inspector J.Opheim BENCH MARK (Assumed elevation) 100 ft Inspectes:tion is` 4/26/24 4/29/24 Location and description da 2 nd 1h Bottom of Siding Y, 4/30/24 4 5/2124 ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp A. Conditional Approval: Date A C2 49 TH P� Septic S stem Y Ben iaqRSchiller "2592 .-Ow CEI Approved Date 5/14/2024 Note: this approval does not include well requirements. PROFEWQO� permit (Rev 05/02/18) CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT DV - FLOW DIVERTER VALVE FS - FLOW SPLITTER MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND PERMIT # OSP241045 PID # 051-801-72 1"=50' THE TABLELANDS, BLOCK 4 LOT 8A FEET 0 50 100Benjamin Schiller CE 12592 R E GISTEREDPROFES S I O N A L E N G INEER 6/14/24 PLAN AS-BUILT TH#1 A B FCO 32.5 MH 34.5 SV 36.5 A B 2CO 38.3 FD 43.0 CO1 89.4 MT1 87.3 9.5 17.0 20.8 23.3 27.5 61.5 59.9 WH I S P E R I N G B I R C H D R I V E 4-BDRM HOME 335 15 ' T & E E A S E M E N T TH#2 FS 330 320 310 300 290 280 270 260 NO EXISTING WELLS - PROPERTIES ARE ON COMMUNITY WATER SYSTEM 1250-GAL SEPTIC TANK (NEW TANK INSTALLED W/ TRENCHES) EXISTING TRENCHES (2) 67' LONG x 5' WIDE, 4' EFFECTIVE DEPTH ABSORPTION TRENCHES MT3 MT1 MT2 MT4 CO4 CO2 CO1 CO3 FS 69.557.1 CO2 64.2 MT2 65.0 74.7 73.9 CO3 104.2 MT3 101.9 78.7 78.3 CO4 78.5 MT4 76.3 85.3 80.8 BM DV 2CO SV MH FCO PROFILE AS-BUILT (NO SCALE) 93.7 88.7 94.3 98.8 FC O MH SV PERMIT # OSP241045 PID # 051-801-72 THE TABLELANDS, BLOCK 4, LOT 8A 97.7 FINISH GRADE 67' DRAINFIELD ROCK MT 1 TH # 2 GROUNDWATER @ 14' 1/19/05 88.6 92.6 CO 1 CO 2 78.0 88.6 92.6 97.5 ORIGINAL GRADE MT 2 2C O 93.5 Benjamin Schiller CE 12592 R E GISTEREDPROFE S S I O N A L E N GINEER 6/14/24 1250 GAL SEPTIC TANK WEST TRENCH 97.3 FINISH GRADE 67' DRAINFIELD ROCK MT 3 TH # 2 GROUNDWATER @ 14' 1/19/05 88.1 92.1 CO 3 CO 4 77.5 88.1 92.1 97.0 ORIGINAL GRADE MT 4 EAST TRENCH 93.0 - 2005 OG 93.5 - 2005 OG MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241045 Work Type: Septic Upgrade Tax Code Number: 05180172000 Site Legal Address: THE TABLELANDS BLK 4 LT 8A G:1559 Site Mailing Address: 23006 WHISPERING BIRCH DR, Chugiak Owner: BOONE SCOTT Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: dent S G � r Department 4/18/2024 4/18/2025 40000 Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: 1 S ``n`� F Date: Issued By: Date: 4 N[�'UH�CaP A L0TY OF HCH0'R G Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON -SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-801-72 Property owner(s) Scott Boone Day phone (907) 244-0769 Mailing address 23006 Whispering Birch Drive, Chugiak, AK 99567 Site address 23006 Whispering Birch Drive, Chugiak, AK 99567 Legal description (Sub'd., Block & Lot) The Tablelands Block 4 Lot 8A Legal description (Township, Range & Section) Lot Size 40,000 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X Septic Tank ElUpgrade ❑x (w/wo ADU) Holding Tank ❑ Renewal ❑ Duplex (D) ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: _1526 Date of Payment: ` Ig+ y Receipt Number: 6�g9y� Permit No. Waiver Fees: Date of Payment: Receipt Number: Waiver No. Permit App_:- : .'_.,:c April 3, 2024 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: The Tablelands Block 4 Lot 8A - Whispering Birch Drive Septic system design Dear On-Site Services Engineer: The septic trenches on the above lot do not pass inspection for a COSA, so we are submitting this permit application for the construction of a new set of absorption trenches. The attached site plan identifies the location of the home and septic location. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. We are proposing building the new trenches in the same place specified in the original permit for the alternate site. The ground surface on the lot slopes very mildly down from the road at about a 5% slope before dropping away sharply to between 35-45% slopes. There are slopes greater than 25% within 50’ of the site, but none greater than 46% within 100’. The trenches have been designed to meet the steep slope criteria of 15.65.210.B.4. Stormwater drainage will not impact this septic system. The new trenches will be constructed parallel to the slope as much as possible. The properties in this neighborhood are all on community water, so there are no conflicts with wells. Please refer to the attached test hole logs, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241045, Curtis Townsend, 04/18/24 CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT DV - FLOW DIVERTER VALVE FS - FLOW SPLITTER MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND 1"=50' THE TABLELANDS, BLOCK 4 LOT 8A FEET 0 50 100Benjamin Schiller CE 12592REGISTEREDPROFESSIONA L E N GINEER 4/3/24 SEPTIC PLAN TH#1 WH I S P E R I N G B I R C H DR I V E 4-BDRM HOME 335 15 ' T&E EA S E M E N T TH#2 FS 330 320 310 300 290 280 270 260 NO EXISTING WELLS - PROPERTIES ARE ON COMMUNITY WATER SYSTEM NEW DIVERTER VALVE EXISTING 1250-GAL SEPTIC TANK TO REMAIN EXISTING TRENCHES TO REMAIN IN SERVICE (2) 67' LONG x 5' WIDE, 4' EFFECTIVE DEPTH ABSORPTION TRENCHES. MAINTAIN >10' SEPARATION FROM EXITING SYSTEM AND >10' BETWEEN NEW ABSORPTION TRENCHES. MT MT MT MT CO CO CO CO 12.0 VEGETATION MUST REMAIN UNDISTURBED 50' DOWNHILL OF NEW TRENCHES Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241045, Curtis Townsend, 04/18/24 THE TABLELANDS, BLOCK 4 LOT 8A TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY Benjamin Schiller CE 12592REGISTEREDPROFESSION A L E N GINEER 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 2'-11" 4' DESIGN FACTORS:SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 54 MIN/IN APPLICATION RATE: 0.45 GPD/SF 5-WIDE TRENCH SYSTEM EXISTING 1250-GAL SEPTIC TANK BOTTOM OF TRENCH: 7'-5" BELOW GRADE (MEASURED FROM HIGH SIDE) FLOW LINE ELEVATION: 3' BELOW GRADE (MEASURED FROM LOW SIDE) 600 GPD / 0.45 GPD/SF / 5' WIDE * 0.5 FACTOR = 133.3 LF TRENCH REQUIRED (134 LF SPECIFIED) GEOTEXTILE FABRIC 6" 4/3/24 PROVIDE ADDITIONAL FILL TO ACCOUNT FOR SETTLEMENT INSULATION 3' MEASURE VERTICAL SEPARATION DISTANCES FROM HIGH SIDE OF TRENCH Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241045, Curtis Townsend, 04/18/24 Municipality of Anchorage Page 1 of 3 Development Services Department On-Site Water and Wastewater Program ' 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.d.enchorage.ak.us (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO50020 PID Number. 051.801-16 S i rpinell Homes Wastewater System: New Addeo 1900 W. Northam Lights, Ste. 200 Anch., AK 99517 ABSORPTION FIELD 344-5678 our 5' Wide Trench LEGAL DESCRIPTION sa Ra4q Taal Devh iron awN.l peas 6 .45 GPDIFl Ft. Bkxk La &tdv Deph to P" OalOtrl kom wwvoi etede Gtw deph Berleeh pp. 4 8 The Tablelands 2 Ft. 4 FL 7U."Oep Rape Seaarl Fa edasd eoora ongn ara Gtew Lu91h. 3.5 Ft. 134 Ft. Well: AWWUWaterSystem Gt.w�. 5 F wle 2 Duta,�ale.eni >10 Ft. FL Cluedolw (Pmae, A S. C): Taal Deph. GeeO ro. eW tleorpeen aee yr Me1aW Ft. FL 1,334 Fe ASTM 3034 PVC 01.1w Dae DMW aura Waa Le Pisano's Dirtworks e 211.2312005 FL nem P1eep sei■ I G..e1e Aowe Gttutl TAN K GPM Ft. Ft SEPARATION DISTANCES Septic To From Septic Tank Absorption Field Lift Station Holding Tank ubi dprivate SewerLtne Anchorage Tank 1,250 wa >200' >200' NIA NIA >25' Steel Two (2) sw,.water >100, >100' N/A NIA LIFT STATION — NONE ON LOT to Lkw >5' >10, NIA NIA c.t Fpuldaw >5' >10, N/A NIA �pW� W a m In In N None Noted P.mp Mt MWMedal Ietltlfrl Yupa patatnd by C~ Dtw BENCH MARK w w w Finished Floor. 100.0 FL Engineer's Stamp Inspections performed by: T. Kimbrough Dates: 1" 2114/2005 E00 .;�,, _49m 2nd 2/2212005 Department of Health and Human Services approval %µ••:•A.-....... ...-. 0 M CI IAL L. ANDL RSON W i . o �a �' `O CF-4.181 � of Reviewed and approved by: Date:� ow taw) �� ?Z ,+44"x:5:.`•. Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number SWO50020 TBM %D Cq U S PID No. 051-801-16 98.28 97.41 Dralnfleld Rock Dralnfleld Rock PROFILE AS -BUILT Scale: 1' — 20' N N S U Y n S U 98.39 97.53 MUNICIPALITY OFANCHORAGE l'?�p Development Services Department 17,2 On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 V (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Feb 04, 2005 Expiration Date: Feb 04, 2006 Permit Number. SWO50020 Parcel ID: 051-801-16 Legal Description: THE TABLELANDS SUBDIVISION BLOCK 4 LOT 8 Design Engineer: 0014 Anderson Engineering Site Address: 23006 WHISPERING BIRCH DRIVE Owner Name: SPINELL HOMES, INC Lot Size: 40000 SO. FT. Owner Address: 23006 WHISPERING BIRCH DRIVE Total Bedrooms: 4 Permit Bedrooms: 4 CHUGIAK . AK 99567 - This permit is for the construction of. ❑✓ Disposal Field ❑/ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By. Issued By: Date: 2-q -Of" Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.enchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. U5l - ol-/6 Permit Number SW Property owner(s) Soinell Homes, Inc. Day phone 344.5678 Mailing address (1)1900 W. Northem Lights Boulevard, Suite 200 Anchorage, AK 99515 a-04DW Mailing address (2) Whispering Birch Drive Zip Code Legal description (Lot, Block & Sub'd.) Lot 8, Block 4, The Tablelands Subdivision Legal description (Section, Township & Range) Lot Size 40,00 SF Acres/Sq.Ft. Number of Bedrooms Four (4) THIS APPLICATION IS FOR: Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: d 2 r lug Waiver Fees: Date of Payment: 4160 Date of Payment: Receipt Number. o L4 r htA Receipt Number. (Rev. 12100) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX January 24, 2005 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 8, Block 4, Tablelands Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer. The owner of Lot 8, Block 4, Tablelands Subdivision intends to construct a new four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is currently served by a community water system. No conflicts exist with adjacent septic systems or wells and the proposed septic system on this lot. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The current drainage pattern is identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Test holes recently placed on the lot indicated silty gravel in the area of the absorption trenches. The accepting soils were tested and found to have a percolation rate of 31 to 60 minutes per inch. No groundwater was found in either test hole during placement but was noted at 14' below the surface during the monitoring period. Our design includes the placement of a new 1,250 -gallon septic tank along with 2 - 67' long by 5' wide by 4' effective depth absorption trenches to collect and treat the sewage generated in the house. The bottom of the trench will be 6' below the surface. The distribution pipe will be 2' below the surface. A flow splitter valve will be placed to assure even flow to each trench. A minimum of 3' of cover will be placed atop the trenches and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at shallow grades from west to east as shown on the Site Plan. The absorption trenches will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service proposed Lot 8, Block 4, Tablelands Subdivision January 24, 2005 Page Two for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, /� J Michael E. Anderson, P.E. Attachments sy 3 N .Fys 9 v'!y a O 0 Cf) m m \..,U) U O,': C)mo O O ^� N 00'.r LJ F 1 0 z h • Q w W Lij J a h Y W W ^ bu¢ iS � I'• 1Za! N M N LOT 8, BLOCK 4, THE TABLELANDS SUBDIVISION DESIGN FACTORS: , SYSTEM REQUIREMENTS: Four Bedroom House S LJ444 �rench System 'A4 T -Q— Pem. Rate: 31-60 Min.Anch 1,250 Gallon Septic Tank Application Rate: A5 GPD/SF 'j;Drainfield Rock yM iEct 4 Bedrooms X 150 GPD/.45 GPD/SF (Application Rate) = 1,333.3 SF Absorption Area 1,334 SF/5 SF/LFx.5(Reducton Factor) = 134 LF Trench Length THEREFORE: Construct 2 - 6T Long x 5' Wide x 4' Effective Depth Absorption Trenches. Flow Line Elevation in Trenches to be 2' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Maintain IV Separation From Water Service on Lot Provide T of Cover Over Trench and 4' Over Septic Tank or Provide 2" Insulation and 2' of Cover. Place Flow Splitter Valve to Assure Even Flow to Each Trench. Natural Backfill 1'6" Geotextile 6" t 4" Perforated T PVC (Holes Down) 47 %�— Drainfield Rock TYPICAL 5' WIDE TRENCH SECTION �•�� (NO SCALE) CF „. NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock ►.. Minimum 4' Separation From Groundwater. Minimum 200 Separation From Wells in the Area. � I MSE ANOEasON Minimum 100' Separation From Surface Water or Streams.s, Minimum 10' Separation From Water Services. Nor?, MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGALDESCRIPTION: LOT 8, BLOCK 4, TABLELANDS S/D PERFORMED FOR: SPINFLL HOMES DATE. 8/18/2004 PROJECT'No.: PARCEL ID#: TECHNICIAN: A. HARALA DEPTII TEST HOLE # 1 (f«l) 1 2 READING OB/OG NET TIME (MINUTES) 3 N�T DRQQP I (INCHES) 4 12/18 SILTY GRAVEL 5 SOME SAND GM 6 30 10.06" 7 COBBLES 8'-10' 8 30 10.62" 9 MORE DENSE WITH DEPTH 10 11 12 13 14 15 16 17 18 19 m SLOPE �t4i Ailmax E. umoesw SITE PLAN SEE SITE PLAN WAS GROUND WATER ENCOUNIERED? NO IF YES @WHAT DErnr Bq, %o GEM OF WATER AFTER MONITORING: 14• 55ON DATE OF MONITORING: 1/19105 11 1 DATE READING GROSS TIM (MINUTES) NET TIME (MINUTES) D WATER (INCHES) N�T DRQQP I (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 12/18 1 2:12 9.5" 2 2:42 30 10.06" .56" 3 3:12 30 10.62" .56" 4 3:42 30 11.18" .56" PERCOLATION RATE- 54 oAjN/INCFp PERC. HOLE DIA 8�� (iNCIiES) TEST RUN BETWEEN�F- .and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECII ENGINEERING TECIiMCAL SERVICE. 1, MICFIAEL E. ANDERSON CERTIFY T11AT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUMCIPLE GUIDELINES IN EFFECT ON TINS DATE: 1/12/2005 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG — PERCOLATION TEST LEGAL DESCRIPTION: LOT 8, BLOCK 4, TABLELANDS S/D PERFORMED FOR: cPINFLL HOMFS DATE: 8/18/2004 PROJECENo.: PARCEL IDe: TECHNICIAN: A. HARALA DEPTH TEST HOLE #2 Occl) 1 2 READING OEI/OG NET TIME (MINUTES) 3 NDR NCHtS) 4 12/18 SILTY GRAVEL 5 SOME SAND GM 6 30 8.19" .56" COBBLES 8'-10' 7 30 8.82" 8 4 9 30 MORE DENSE WITH DEPTH 10 11 12 13 14 LOU 1 1 1 SITF PI AN SEE SITE PLAN WAS GROUND WATER ENMNTERED7 No IF YES @ WHAT DEPTH+ o OF.PITi OF WATER ALTER MONFHMING: I4• 89 5% DATE OF MONITORDIO: 1o 06 S DATE READING GROSS TIM (MINUTE$) NET TIME (MINUTES) DEPTH To WATERyCT (INCHES) NDR NCHtS) TEST HOLE PRESOAKED PRIOR TO TESTING: 12/18 1 1:35 7.63" 2 2:05 30 8.19" .56" 3 2:35 30 8.82" .63" 4 3:05 30 9.45" .63" PERCOLATION RATE- 47 (MN/INCH) PERC. HOLE DIA R. �� (INCHES) TEST RUN BM WEEN�FT. and -!—FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATES __ _ _ 1/24/2005 ONSITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 8, BLOCK 4, THE TABLELANDS SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250 -gallon septic tank at the location shown on the site plan. Work also includes the construction of 2 new absorption trenches each 67' long by 5' wide with 4' of drainfield rock beneath the distribution piping also at the location shown on the Site Plan. The total depth of the trenches will be 6' below existing ground and the distribution pipe will be placed at 2' below the existing ground surface. A Bull Run Flow Splitter Valve must be installed to assure equal flow to each trench. All components of the new absorption trenches and septic tank must be constructed a minimum of 100' from any surface water and 10' from the water service lines on this and adjacent lots. A minimum of 4' of cover is required over the septic tank and 3' over the absorption trenches. In lieu of cover 2' of direct bury insulation and 2' of cover may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor is also responsible to assure the separation distance from wells and surface water in the area is maintained. The engineer will accept no responsibility for Contractor errors. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. Lot 8, Block 4, The Tablelands Subdivision January 24, 2005 Page 2 of 4 SEPTIC TANK INSTALLATION 1. A new 1,250 -gallon septic tank must be procured from a certified septic tank manufacturer. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. The Contractor is solely responsible to assure these separation distances are met. Lot 8, Block 4, The Tablelands Subdivision January 24, 2005 Page 3 of 4 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections must be completed during the construction of the septic system. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The Contractor must notify the engineer 4 hours prior to the inspection to prevent delays. Lot 8, Block 4, The Tablelands Subdivision January 24, 2005 Page 4 of 4 The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. His measurements must include verification that the proper separation distances have been met. A certified surveyed as -built may also be required to assure the proper separation distances are met from wells in the area. The as -built will also include separation distances from streams or surface water in the area. Parcel I.D. 051-801-72 Certificate of On -Site Systems Approval Expiration Date: Legal description THE TABLELANDS BILK 4 LT 8A Site address 23006 WHISPERING BIRCH DR Chugiak AK Current property owner(s) BOONE 5/2/2025 X The On -site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: Original Certificate Date: 6/24/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA ApprovaUune 2022 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 051-801-72 Complete legal description The Tablelands Block 4 Lot 8A Location (site address) 23006 Whispering Birch Drive, Chugiak, AK 99567 Current property owner(s) Scott & Reta Boone _ Day phone (907) 244-0769 2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: E] Private Well 0 Private Well serving 2 dwelling units El Private Well serving 3+ dwelling units r0_1 Community Well or Public F-1 Water Storage 4. TYPE OF WASTEWATER DISPOSAL: 0 Private Septic R Private Septic serving 2 dwelling units El Holding Tank 0 Community Septic or Public Sewer 5. SEPTIC TANK: F] Steel X Plastic EJ Concrete M Fiberglass Age New - See advisory if steel older than 20 years 6. ABSORPTION FIELD: R AWWTS R Bed E] Deep Trench FE-1 Wide Trench R Seepage Pit Waiver request for: Expedited review requested: D Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ Date of Payment 0 C'�? COSA # S 2- Waiver Fee $ Date of Payment Waiver # COSA Application —June 2022 The Tablelands Block 4 Lot 8A 051-801-72 Property is served by city water. N/A N/A N/A Benjamin Schiller, P.E. (907) 522-7773 c� o o-0o�D < y m (Am S n S ' a— 3 0m o ID ° S 3 m y.3 o y y S rt y O S(Q CD 'Ap< m a 0 ro aD O IA o'O m = a m G W > > r „ N y p C) p y m CT CL o,<a� S 'O S -� y O, G m y m y v= p �.m < 7 o m ?m p m O a--1 D y ?� -°+. n O O Dm� m O r p m I p 7 �5� a ,< 0 z (D 7 p p j C7 -O y itp m p N� p CL p 70 aNm m 0 L ix a.-' C: om a�pp-«0 2 3 I� m p m S- v O 7 I 0.y 3.�Vl O m I p S j I S3 S—m z1° rt S I m y m p y 0 m m�3 m X I >>omn� o� om IN >>°mz0 a0 I um, 0,v0 3. a O I ?" y p O (AI 0 pyV'm Qp So a I H,m D < O p 7 7 y C S m S D3 o m�mm o m p m m +3 m -o a rt p p p O y — p � Q O I.1, 0 � CD N� D O Z3 n 0--. Q �(D U) CD l< — O� N n om�a� oO O V =- c ° v o 0 7 Ln p ha x ®y N m C V ° o Ln 0 m3 ,c O co 3 Ln N rt sN�ST�� a o G7 Z. PY D D ON Q y (p ° O ➢ • (O .� rn to Cn �� w d O O O Ln Ail FA O 'O z D fN m C C) m v V r O o 0 0 �IV 0 O L n S ]a °• -Z FR/arc \ ,7 F 774 < �. m= \ OJ \ 7 9� `o ?.O N � nAn z • D O U) m O ?2O, Z V al O =1 n m mo J A 11n D r 0 V U) m m z -I t Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program ` 4700 South Bragaw St *A9 P.O. Box 196650 Anchorage, AK 99519-6650 r` • www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051.801.16 HAA #_20 Expiration Date: _Vvz/ cn o 1. GENERAL INFORMATION Complete legal description Lot 6 Block 4 The Tablelands Subdivision Location (site address or directions) 23006 Whispering Birch Drive Current Property owner(s) Spinell Homes, Inc. Day phone 3445678 Mailing address 1900 Northern Lights Blvd. Anchorage AK 99517 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System Four 4 TYPE OF WASTEWATER DISPOSAL: ❑ Individual On-site ❑ Individual Holding tank ❑ ❑ Community On-site ❑ ® Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given In paragraph 5 by an Independent professional civil engineer registered In the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.)' Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system Is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the Information obtained from the Municipality of Anchorage files and from my Investigation and Inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of Installation. Name of Firm Anderson Engineering Phone 522-M3 Address _P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 012212005 5. DSD SIGNATURE _4e�f Approved for L_ bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments Attachments:HAA Checklist y o �opmg Maintenance�f Wiement� Septic System Advisory Well Flow Advisory Supplemental Engineer's Report Other By: k , . A bmt tiQ D— Original Certificate Date: c (Pw 12M) A. WELL DATA Well type — Date completed — Total depth ft. Date of test Static water level Well production Municipality of Anchorage Development Services Department Building Safety Division OnSlte Water & Wastewater Program 47W South Bregaw St P.O. Box 198850 Anchorage, AK 99519 -SM www.cl.anchorage.ak.us (907)343.7904 HEALTH AUTHORITY APPROVAL CHECKLIST If A, B, or C provide PWSID 0 — Web Log (YIN) Sanitary seal (YIN) — Cased to R FROM WELL LOG WATER SAMPLE RESULTS: Coftrm colonlesH00 ml. Date of sample: B. SEPTICfHOLDING TANK DATA Wires property protected (YIN) Casing height (above ground) in. AT INSPECTION R ft 9.p -m. O.P.M. Nitrate mg.A. Other bacteria colonlesl100 ml. Collected by: Tank Type/Material Seoticfliteei Tank size 1.250 gat Number of Compartments; Foundation cleanout (YIN) Y Depression over tank (YIN) N .: = i . r, I Cleanouts (YM) Y High water atarrn (YM) Y Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA Date Installed pb2=5 Sob rating (g.p.dJtt= or fe/bdrm)iS 0 System type V YVlde Shallow Tronch Length 134 ft. Width 5 R Gravel below pipe 4 R Total depth 01 IL Eftabsorption area +au ft= Monitoring tube X Depression over field tj Date of adequacy test Results (Pass/Fab) For — bedrooms Fluid depth in absorption field before test — in. Water added— gai. New depth— in. Elapsed Time: — min. Final fluid depth — In. Absorption rate x g.p.d. Any rejuvenation treatment (past 12 mo.) (YM & type) N If yes, give date D. LIFT STATION Date installed 'Pump on' level at _ in. Datum Size In gallons 'Pump ofr level at _ In. Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot WA Absorption field on lot NIA Public sewer main KFA Sewer /septic service line WA ManhoWAccess (YIN) High water alarm level at in. Meets alarm d dradt rwMmmw ts9 On adjacent lots MIA On adjacent lots WA Public sewer manhole/cleanout WA Holding tank WA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 3,5' Property line >' Absorption field 3,S Water main >10' Water service Ane 3,_10' Surface water MIV Wells on adjacent lots >2W SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property Ane >17 Building foundation >10' Water main >10' Water Service line 3,111' Surface water 3,1W Driveway. paftWVehlde storage 4' Curtain drain _ None Noted Wells on adjacent lots >-2W F. COMMENTS G. ENGINEER'S CERTIFICATION (� "' \•• I certify that I have determined thmugh field inspections and V%%,N review of Munk4pal records that the above systems am in conformance w!!h MOA HAA guidelines In effect on this dateEngineer's Printed Name Michael E Anderson. RE CcDate 812 105r, HAA Fee $ 57.50 -r 1-1500 Waterer Fee S Date of Payment -�7 tete of Payment Receipt Number %,9&40 [_%WSLCS)l VNMReceipt Number (Rev. 1M k §tGm} k moaj D m0A�$§ emnz2O # Rk§m\�-Q } 0 2§§ice [� 4� o § ®2%§ zE #;&§t® _� m- \ moP-k� Orn o(n \ m td £�2gm 3 iiR32«m X o n n � r n k /Ek§/��kkk2 § \k/\§\kk§d� En 27�nO�§2§q&/ o n� on o_ \ � � U)z 0 / & q m = ® m v# / /rri0 CD=// / �Z 0 6rri //§\k2\ §�g$�omma�2 � 2 rri z �>I O CD I r- 00 m o>� OCU O W C/) C CD < _C/) O . Z