On -Site Water and Wastewater Section - (907) 343-7904 Page 1 of 3
ON
-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP241045
PID Number: 051-801-72
Dwelling: RN Single Family (SF)
El with ADU [:1 Duplex (D) El Two Single Family Project: R New RE Upgrade
Name
Scott Boone
ABSORPTION FIELD
R Deep Trench RN Wide Trench El Bed R Mound
Site Address
23006 Whispering
Birch Drive
EJ Other
Phone
Number of Bedrooms
Soil Rating
depth from original grade
(907) 244-0769
4
0.45 GPD/SF
JTotal
8.9 / 8.9 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
4.9/4.9 Ft.
Gravel depth beneath pipe
4.0/4.0 Ft.
Subdivision
Block Lot
The Tablelands
4 8A
Fill added above original grade
0.2/0.3 Ft.
Gravel length
67 / 67 Ft.
Township Range Section
Gravel width
5/5 Ft.
Beds: Number of Lines
N/A
Distance between lines
N/A Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
2
Dist. between trenches
8
From
Tank
Field
Tank
Line
1,340 Ft2
Ft.
Well
>100'
>1 00'
N/A
N/A
>25
TANK Fm] Septic [] S.T.E.P. El Holding El Other
Manufacturer
Greer
Capacity
1250 Gal.
Surface Water
>1 00'
>100'
N/A
N/A
Material
Plastic
Number of compartments
2
Lot Line
>5'
>10'
N/A
N/A
NA
Foundation
>10'
>10'
N/A
N/A
LIFT STATION
IMan er
Capacity
Gal.
Remarks Trenches listed East / West
Alarm location
I installed by
PIPE MATERIAL House to tank D3034 drainfieldTankto D3034
Installer
A. C. E. S.
Drainfield D3034 CO/MT D3034
Inspector J.Opheim
BENCH MARK (Assumed elevation) 100 ft
Inspectes:tion
is` 4/26/24
4/29/24
Location and description
da
2 nd
1h
Bottom of Siding
Y, 4/30/24
4 5/2124
ON -SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
A.
Conditional Approval:
Date
A
C2
49 TH
P�
Septic S stem
Y
Ben iaqRSchiller
"2592 .-Ow
CEI
Approved
Date
5/14/2024
Note: this approval
does not include well requirements.
PROFEWQO�
permit
(Rev 05/02/18)
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
DV - FLOW DIVERTER VALVE
FS - FLOW SPLITTER
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
PERMIT # OSP241045 PID # 051-801-72
1"=50'
THE TABLELANDS, BLOCK 4 LOT 8A
FEET
0 50 100Benjamin Schiller
CE 12592
R
E
GISTEREDPROFES S I O N A L E N G INEER
6/14/24
PLAN AS-BUILT
TH#1
A B
FCO 32.5
MH 34.5
SV 36.5
A
B
2CO 38.3
FD 43.0
CO1 89.4
MT1 87.3
9.5
17.0
20.8
23.3
27.5
61.5
59.9
WH
I
S
P
E
R
I
N
G
B
I
R
C
H
D
R
I
V
E
4-BDRM HOME
335
15
'
T
&
E
E
A
S
E
M
E
N
T
TH#2
FS
330
320
310 300
290
280 270 260
NO EXISTING WELLS - PROPERTIES ARE ON COMMUNITY WATER SYSTEM
1250-GAL SEPTIC TANK
(NEW TANK INSTALLED
W/ TRENCHES)
EXISTING TRENCHES
(2) 67' LONG x 5' WIDE, 4' EFFECTIVE
DEPTH ABSORPTION TRENCHES
MT3
MT1
MT2
MT4 CO4
CO2
CO1
CO3
FS 69.557.1
CO2 64.2
MT2 65.0
74.7
73.9
CO3 104.2
MT3 101.9
78.7
78.3
CO4 78.5
MT4 76.3
85.3
80.8
BM DV
2CO
SV
MH
FCO
PROFILE AS-BUILT
(NO SCALE)
93.7
88.7
94.3
98.8
FC
O
MH
SV
PERMIT # OSP241045 PID # 051-801-72
THE TABLELANDS, BLOCK 4, LOT 8A
97.7 FINISH GRADE
67'
DRAINFIELD ROCK
MT
1
TH
#
2
GROUNDWATER @ 14' 1/19/05
88.6
92.6
CO
1
CO
2
78.0
88.6
92.6
97.5 ORIGINAL GRADE MT
2
2C
O
93.5
Benjamin Schiller
CE 12592
R
E
GISTEREDPROFE S S I O N A L E N GINEER
6/14/24
1250 GAL
SEPTIC TANK
WEST TRENCH
97.3 FINISH GRADE
67'
DRAINFIELD ROCK
MT
3
TH
#
2
GROUNDWATER @ 14' 1/19/05
88.1
92.1
CO
3
CO
4
77.5
88.1
92.1
97.0 ORIGINAL GRADE MT
4
EAST TRENCH
93.0 - 2005 OG
93.5 - 2005 OG
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP241045
Work Type: Septic Upgrade
Tax Code Number: 05180172000
Site Legal Address: THE TABLELANDS BLK 4 LT 8A G:1559
Site Mailing Address: 23006 WHISPERING BIRCH DR, Chugiak
Owner: BOONE SCOTT
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms:
dent S
G �
r
Department
4/18/2024
4/18/2025
40000
Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: 1 S ``n`� F Date:
Issued By: Date:
4
N[�'UH�CaP A L0TY OF HCH0'R G
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON -SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 051-801-72
Property owner(s) Scott Boone Day phone (907) 244-0769
Mailing address 23006 Whispering Birch Drive, Chugiak, AK 99567
Site address 23006 Whispering Birch Drive, Chugiak, AK 99567
Legal description (Sub'd., Block & Lot) The Tablelands Block 4 Lot 8A
Legal description (Township, Range & Section)
Lot Size 40,000 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
❑X
Initial ❑
Single Family (SF) ❑X
Septic Tank
ElUpgrade
❑x
(w/wo ADU)
Holding Tank
❑
Renewal ❑
Duplex (D) ❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: _1526
Date of Payment: ` Ig+ y
Receipt Number: 6�g9y�
Permit No.
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
Permit App_:- : .'_.,:c
April 3, 2024
MOA Development Services, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: The Tablelands Block 4 Lot 8A - Whispering Birch Drive
Septic system design
Dear On-Site Services Engineer:
The septic trenches on the above lot do not pass inspection for a COSA, so we are submitting
this permit application for the construction of a new set of absorption trenches. The attached site
plan identifies the location of the home and septic location. No conflicts exist between this
proposed system and any other well or septic system, whether on this lot or adjacent lots. We are
proposing building the new trenches in the same place specified in the original permit for the
alternate site.
The ground surface on the lot slopes very mildly down from the road at about a 5% slope before
dropping away sharply to between 35-45% slopes. There are slopes greater than 25% within 50’
of the site, but none greater than 46% within 100’. The trenches have been designed to meet the
steep slope criteria of 15.65.210.B.4. Stormwater drainage will not impact this septic system.
The new trenches will be constructed parallel to the slope as much as possible.
The properties in this neighborhood are all on community water, so there are no conflicts with
wells. Please refer to the attached test hole logs, plan and profile pages for the septic design. If
this design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Benjamin Schiller, PE
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241045, Curtis Townsend, 04/18/24
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
DV - FLOW DIVERTER VALVE
FS - FLOW SPLITTER
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
1"=50'
THE TABLELANDS, BLOCK 4 LOT 8A
FEET
0 50 100Benjamin Schiller
CE 12592REGISTEREDPROFESSIONA L E N GINEER
4/3/24
SEPTIC PLAN
TH#1
WH
I
S
P
E
R
I
N
G
B
I
R
C
H
DR
I
V
E
4-BDRM HOME
335
15
'
T&E
EA
S
E
M
E
N
T
TH#2
FS
330
320
310 300
290
280 270 260
NO EXISTING WELLS - PROPERTIES ARE ON COMMUNITY WATER SYSTEM
NEW DIVERTER VALVE
EXISTING 1250-GAL
SEPTIC TANK TO REMAIN
EXISTING TRENCHES TO
REMAIN IN SERVICE
(2) 67' LONG x 5' WIDE, 4' EFFECTIVE
DEPTH ABSORPTION TRENCHES.
MAINTAIN >10' SEPARATION FROM
EXITING SYSTEM AND >10' BETWEEN
NEW ABSORPTION TRENCHES.
MT
MT
MT
MT CO
CO
CO
CO
12.0
VEGETATION MUST
REMAIN UNDISTURBED 50'
DOWNHILL OF NEW
TRENCHES
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241045, Curtis Townsend, 04/18/24
THE TABLELANDS, BLOCK 4 LOT 8A
TYPICAL TRENCH SECTION
(NO SCALE)
NOTES:
1. GRADE AREA OVER TRENCH TO DRAIN AWAY
2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2'
WITH 2" OF INSULATION
3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER
THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY
Benjamin Schiller
CE 12592REGISTEREDPROFESSION A L E N GINEER
4" PERFORATED PVC (HOLES DOWN)
DRAINFIELD ROCK
5'
2'-11"
4'
DESIGN FACTORS:SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW
PERK RATE: 54 MIN/IN
APPLICATION RATE: 0.45 GPD/SF
5-WIDE TRENCH SYSTEM
EXISTING 1250-GAL SEPTIC TANK
BOTTOM OF TRENCH: 7'-5" BELOW GRADE (MEASURED FROM HIGH SIDE)
FLOW LINE ELEVATION: 3' BELOW GRADE (MEASURED FROM LOW SIDE)
600 GPD / 0.45 GPD/SF / 5' WIDE * 0.5 FACTOR = 133.3 LF TRENCH REQUIRED (134 LF SPECIFIED)
GEOTEXTILE FABRIC
6"
4/3/24
PROVIDE ADDITIONAL FILL TO
ACCOUNT FOR SETTLEMENT
INSULATION
3'
MEASURE VERTICAL
SEPARATION DISTANCES
FROM HIGH SIDE OF TRENCH
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241045, Curtis Townsend, 04/18/24
Municipality of Anchorage Page 1 of 3
Development Services Department
On-Site Water and Wastewater Program
' 4700 South Bragaw Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.d.enchorage.ak.us (907) 343-7904
ONSITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number. SWO50020 PID Number. 051.801-16
S i
rpinell Homes
Wastewater System: New
Addeo
1900 W. Northam Lights, Ste. 200 Anch., AK 99517
ABSORPTION FIELD
344-5678 our
5' Wide Trench
LEGAL DESCRIPTION
sa Ra4q
Taal Devh iron awN.l peas
6
.45 GPDIFl
Ft.
Bkxk La &tdv
Deph to P" OalOtrl kom wwvoi etede
Gtw deph Berleeh pp.
4 8 The Tablelands
2 Ft.
4 FL
7U."Oep Rape Seaarl
Fa edasd eoora ongn ara
Gtew Lu91h.
3.5 Ft.
134 Ft.
Well: AWWUWaterSystem
Gt.w�.
5
F wle
2
Duta,�ale.eni
>10
Ft.
FL
Cluedolw (Pmae, A S. C):
Taal Deph. GeeO ro.
eW tleorpeen aee
yr Me1aW
Ft. FL
1,334 Fe
ASTM 3034 PVC
01.1w
Dae DMW aura Waa Le
Pisano's Dirtworks
e
211.2312005
FL
nem
P1eep sei■
I
G..e1e Aowe Gttutl
TAN
K
GPM
Ft.
Ft
SEPARATION DISTANCES
Septic
To
From
Septic
Tank
Absorption
Field
Lift
Station
Holding
Tank
ubi dprivate
SewerLtne
Anchorage Tank
1,250
wa
>200'
>200'
NIA
NIA
>25'
Steel
Two (2)
sw,.water
>100,
>100'
N/A
NIA
LIFT STATION — NONE ON LOT
to Lkw
>5'
>10,
NIA
NIA
c.t
Fpuldaw
>5'
>10,
N/A
NIA
�pW�
W a m
In
In
N
None
Noted
P.mp Mt
MWMedal Ietltlfrl Yupa patatnd by
C~ Dtw
BENCH MARK
w w w
Finished Floor.
100.0 FL
Engineer's Stamp
Inspections performed by: T. Kimbrough Dates: 1" 2114/2005
E00
.;�,, _49m
2nd 2/2212005
Department of Health and Human Services approval
%µ••:•A.-....... ...-.
0 M CI IAL L. ANDL RSON W i
. o �a
�'
`O CF-4.181
�
of
Reviewed and approved by: Date:�
ow taw)
�� ?Z
,+44"x:5:.`•.
Municipality of Anchorage Page 3 of 3
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number SWO50020
TBM
%D Cq
U S
PID No. 051-801-16
98.28
97.41
Dralnfleld Rock
Dralnfleld Rock
PROFILE AS -BUILT
Scale: 1' — 20'
N N
S U
Y n
S U
98.39
97.53
MUNICIPALITY OFANCHORAGE l'?�p
Development Services Department 17,2
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519.6650 V
(907) 343-7904
ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Feb 04, 2005
Expiration Date: Feb 04, 2006
Permit Number. SWO50020 Parcel ID: 051-801-16
Legal Description: THE TABLELANDS SUBDIVISION BLOCK 4 LOT 8
Design Engineer: 0014 Anderson Engineering Site Address: 23006 WHISPERING BIRCH DRIVE
Owner Name: SPINELL HOMES, INC Lot Size: 40000 SO. FT.
Owner Address: 23006 WHISPERING BIRCH DRIVE Total Bedrooms: 4 Permit Bedrooms: 4
CHUGIAK . AK 99567 -
This permit is for the construction of.
❑✓ Disposal Field ❑/ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be In accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By.
Issued By:
Date:
2-q -Of"
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.enchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. U5l - ol-/6 Permit Number SW
Property owner(s) Soinell Homes, Inc. Day phone 344.5678
Mailing address (1)1900 W. Northem Lights Boulevard, Suite 200 Anchorage, AK 99515
a-04DW
Mailing address (2) Whispering Birch Drive Zip Code
Legal description (Lot, Block & Sub'd.) Lot 8, Block 4, The Tablelands Subdivision
Legal description (Section, Township & Range)
Lot Size 40,00 SF Acres/Sq.Ft. Number of Bedrooms Four (4)
THIS APPLICATION IS FOR:
Sewer Only ® Well Only ❑
Sewer and Well ❑ Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees: d 2 r lug Waiver Fees:
Date of Payment: 4160 Date of Payment:
Receipt Number. o L4 r htA Receipt Number.
(Rev. 12100)
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 522-6779 FAX
January 24, 2005
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 8, Block 4, Tablelands Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer.
The owner of Lot 8, Block 4, Tablelands Subdivision intends to construct a new four-
bedroom home on the lot. We are therefore requesting a permit be issued for the
construction of a new septic system to serve the new home. The subdivision is currently
served by a community water system. No conflicts exist with adjacent septic systems or
wells and the proposed septic system on this lot. The attached Site Plan and backup
documentation identify the location and configuration of the proposed septic system and
alternate site. The current drainage pattern is identified on the Site Plan. The drainage
pattern will be maintained after development of this lot is complete.
Test holes recently placed on the lot indicated silty gravel in the area of the absorption
trenches. The accepting soils were tested and found to have a percolation rate of 31 to
60 minutes per inch. No groundwater was found in either test hole during placement but
was noted at 14' below the surface during the monitoring period. Our design includes
the placement of a new 1,250 -gallon septic tank along with 2 - 67' long by 5' wide by 4'
effective depth absorption trenches to collect and treat the sewage generated in the
house. The bottom of the trench will be 6' below the surface. The distribution pipe will
be 2' below the surface. A flow splitter valve will be placed to assure even flow to each
trench. A minimum of 3' of cover will be placed atop the trenches and a minimum of 4'
of cover will be placed atop the new septic tank.
The ground surface on the lot slopes at shallow grades from west to east as shown on
the Site Plan. The absorption trenches will be constructed parallel with the slope of the
ground surface as much as possible in conformance with Municipal requirements. The
new septic system will be constructed a minimum of 10' from the water service proposed
Lot 8, Block 4, Tablelands Subdivision
January 24, 2005
Page Two
for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any
surface water in the area.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely, /� J
Michael E. Anderson, P.E.
Attachments
sy 3
N
.Fys
9
v'!y
a
O
0
Cf)
m
m \..,U) U
O,':
C)mo
O O ^�
N
00'.r
LJ F
1 0 z
h • Q
w
W Lij J
a h
Y
W
W ^ bu¢
iS � I'• 1Za!
N M
N
LOT 8, BLOCK 4, THE TABLELANDS SUBDIVISION
DESIGN FACTORS: , SYSTEM REQUIREMENTS:
Four Bedroom House S LJ444 �rench System 'A4 T -Q—
Pem. Rate: 31-60 Min.Anch 1,250 Gallon Septic Tank
Application Rate: A5 GPD/SF 'j;Drainfield Rock yM iEct
4 Bedrooms X 150 GPD/.45 GPD/SF (Application Rate) = 1,333.3 SF Absorption Area
1,334 SF/5 SF/LFx.5(Reducton Factor) = 134 LF Trench Length
THEREFORE: Construct 2 - 6T Long x 5' Wide x 4' Effective Depth Absorption Trenches.
Flow Line Elevation in Trenches to be 2' Below Original Ground Surface. Total Depth to be
6' Below Existing Ground. Maintain IV Separation From Water Service on Lot Provide T of
Cover Over Trench and 4' Over Septic Tank or Provide 2" Insulation and 2' of Cover.
Place Flow Splitter Valve to Assure Even Flow to Each Trench.
Natural
Backfill
1'6"
Geotextile
6" t 4" Perforated
T
PVC (Holes Down)
47 %�— Drainfield Rock
TYPICAL 5' WIDE TRENCH SECTION �•��
(NO SCALE) CF „.
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock ►..
Minimum 4' Separation From Groundwater.
Minimum 200 Separation From Wells in the Area. � I MSE ANOEasON
Minimum 100' Separation From Surface Water or Streams.s,
Minimum 10' Separation From Water Services. Nor?,
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
LEGALDESCRIPTION: LOT 8, BLOCK 4, TABLELANDS S/D
PERFORMED FOR: SPINFLL HOMES
DATE. 8/18/2004 PROJECT'No.:
PARCEL ID#: TECHNICIAN: A. HARALA
DEPTII TEST HOLE # 1
(f«l)
1
2
READING
OB/OG
NET TIME
(MINUTES)
3
N�T DRQQP
I (INCHES)
4
12/18
SILTY GRAVEL
5
SOME SAND
GM
6
30
10.06"
7
COBBLES 8'-10'
8
30
10.62"
9
MORE DENSE WITH DEPTH
10
11
12
13
14
15
16
17
18
19
m
SLOPE
�t4i
Ailmax E. umoesw
SITE PLAN
SEE SITE PLAN
WAS GROUND WATER ENCOUNIERED? NO
IF YES @WHAT DErnr Bq, %o
GEM OF WATER AFTER MONITORING: 14• 55ON
DATE OF MONITORING: 1/19105 11 1
DATE
READING
GROSS TIM
(MINUTES)
NET TIME
(MINUTES)
D WATER
(INCHES)
N�T DRQQP
I (INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
12/18
1
2:12
9.5"
2
2:42
30
10.06"
.56"
3
3:12
30
10.62"
.56"
4
3:42
30
11.18"
.56"
PERCOLATION RATE- 54 oAjN/INCFp PERC. HOLE DIA 8�� (iNCIiES)
TEST RUN BETWEEN�F- .and 5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY VETECII ENGINEERING TECIiMCAL SERVICE. 1, MICFIAEL E. ANDERSON CERTIFY T11AT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUMCIPLE GUIDELINES IN EFFECT ON TINS
DATE: 1/12/2005
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG — PERCOLATION TEST
LEGAL DESCRIPTION: LOT 8, BLOCK 4, TABLELANDS S/D
PERFORMED FOR: cPINFLL HOMFS
DATE: 8/18/2004 PROJECENo.:
PARCEL IDe: TECHNICIAN: A. HARALA
DEPTH TEST HOLE #2
Occl)
1
2
READING
OEI/OG
NET TIME
(MINUTES)
3
NDR
NCHtS)
4
12/18
SILTY GRAVEL
5
SOME SAND
GM
6
30
8.19"
.56"
COBBLES 8'-10'
7
30
8.82"
8
4
9
30
MORE DENSE WITH DEPTH
10
11
12
13
14
LOU
1
1
1
SITF PI AN
SEE SITE PLAN
WAS GROUND WATER ENMNTERED7 No
IF YES @ WHAT DEPTH+ o
OF.PITi OF WATER ALTER MONFHMING: I4• 89 5%
DATE OF MONITORDIO: 1o 06 S
DATE
READING
GROSS TIM
(MINUTE$)
NET TIME
(MINUTES)
DEPTH To
WATERyCT
(INCHES)
NDR
NCHtS)
TEST HOLE PRESOAKED PRIOR TO TESTING:
12/18
1
1:35
7.63"
2
2:05
30
8.19"
.56"
3
2:35
30
8.82"
.63"
4
3:05
30
9.45"
.63"
PERCOLATION RATE- 47 (MN/INCH) PERC. HOLE DIA R. �� (INCHES)
TEST RUN BM WEEN�FT. and -!—FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATES __ _ _ 1/24/2005
ONSITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 8, BLOCK 4, THE TABLELANDS SUBDIVISION
GENERAL:
The scope of this project includes the procurement and placement of a
new 1,250 -gallon septic tank at the location shown on the site plan.
Work also includes the construction of 2 new absorption trenches each
67' long by 5' wide with 4' of drainfield rock beneath the distribution
piping also at the location shown on the Site Plan. The total depth of
the trenches will be 6' below existing ground and the distribution pipe
will be placed at 2' below the existing ground surface. A Bull Run Flow
Splitter Valve must be installed to assure equal flow to each trench. All
components of the new absorption trenches and septic tank must be
constructed a minimum of 100' from any surface water and 10' from the
water service lines on this and adjacent lots. A minimum of 4' of cover
is required over the septic tank and 3' over the absorption trenches. In
lieu of cover 2' of direct bury insulation and 2' of cover may be placed.
2. Construction shall be in accordance with the approved site plan, design
drawings, Municipal Permit with any special provisions or conditions,
and all applicable State and Municipal Wastewater Disposal
Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines. The Contractor is also responsible to assure the
separation distance from wells and surface water in the area is
maintained. The engineer will accept no responsibility for Contractor
errors.
4. Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified by
the Municipal Department of Health and Human Services for system
installations. Owners installing their own systems must receive prior
approval from D.H.H.S. before beginning system installation.
Lot 8, Block 4, The Tablelands Subdivision
January 24, 2005
Page 2 of 4
SEPTIC TANK INSTALLATION
1. A new 1,250 -gallon septic tank must be procured from a certified septic
tank manufacturer.
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well. The Contractor is solely
responsible to assure these separation distances are met.
Lot 8, Block 4, The Tablelands Subdivision
January 24, 2005
Page 3 of 4
6. Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic tank
manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Femco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections must be
completed during the construction of the septic system. These inspections
must be conducted under the supervision of a professional engineer
registered in the State of Alaska. The first inspection must be conducted
after the excavation of trenches, beds or pits and before the installation of
any gravel. A septic tank may be set in place, but may not be backfilled.
The Contractor must notify the engineer 4 hours prior to the inspection to
prevent delays.
Lot 8, Block 4, The Tablelands Subdivision
January 24, 2005
Page 4 of 4
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as -built of the completed system.
His measurements must include verification that the proper separation
distances have been met. A certified surveyed as -built may also be
required to assure the proper separation distances are met from wells in
the area. The as -built will also include separation distances from streams
or surface water in the area.
Parcel I.D. 051-801-72
Certificate of On -Site Systems Approval
Expiration Date:
Legal description THE TABLELANDS BILK 4 LT 8A
Site address 23006 WHISPERING BIRCH DR Chugiak AK
Current property owner(s) BOONE
5/2/2025
X The On -site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
Original Certificate Date: 6/24/2024
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA ApprovaUune 2022
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 051-801-72
Complete legal description
The Tablelands Block 4 Lot 8A
Location (site address) 23006 Whispering Birch Drive, Chugiak, AK 99567
Current property owner(s) Scott & Reta Boone _ Day phone (907) 244-0769
2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: E] Private Well 0 Private Well serving 2 dwelling units
El Private Well serving 3+ dwelling units r0_1 Community Well or Public
F-1 Water Storage
4. TYPE OF WASTEWATER DISPOSAL: 0 Private Septic R Private Septic serving 2 dwelling units
El Holding Tank 0 Community Septic or Public Sewer
5. SEPTIC TANK: F] Steel X Plastic EJ Concrete M Fiberglass
Age New - See advisory if steel older than 20 years
6. ABSORPTION FIELD: R AWWTS R Bed E] Deep Trench FE-1 Wide Trench R Seepage Pit
Waiver request for:
Expedited review requested: D
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On -site staff
to verify the accuracy of the information provided.
COSA Fee $
Date of Payment
0 C'�?
COSA # S 2-
Waiver Fee $
Date of Payment
Waiver #
COSA Application —June 2022
The Tablelands Block 4 Lot 8A 051-801-72
Property is served by city water.
N/A N/A
N/A
Benjamin Schiller, P.E.
(907) 522-7773
c� o o-0o�D
< y m (Am S n S
' a— 3 0m
o ID
° S 3 m y.3 o
y y S rt y O S(Q CD
'Ap< m a 0
ro aD
O IA o'O m = a m G W
> > r „
N y p C)
p y m
CT CL o,<a� S
'O S -�
y O, G m y m y v= p
�.m <
7 o m
?m p m O a--1
D y
?� -°+. n O O Dm�
m O r
p m I p 7 �5�
a ,< 0 z (D
7 p p j C7
-O y itp m p N�
p CL p 70 aNm
m 0 L ix a.-' C:
om a�pp-«0 2
3 I� m p m S- v O
7 I 0.y 3.�Vl
O m I p
S j
I S3 S—m z1°
rt S I m y m p
y 0 m
m�3 m
X I >>omn�
o�
om IN >>°mz0
a0 I um, 0,v0 3. a
O I ?" y p O
(AI 0 pyV'm
Qp So a I
H,m D <
O p 7
7 y C S
m S
D3 o m�mm
o m p m m
+3 m -o
a rt p
p p O
y —
p
� Q
O
I.1, 0
�
CD
N�
D
O
Z3 n
0--.
Q
�(D
U)
CD
l< —
O�
N n
om�a�
oO O
V =-
c ° v o 0
7 Ln p
ha x
®y N m
C
V °
o Ln
0
m3
,c
O co
3 Ln
N
rt sN�ST��
a o G7
Z.
PY D
D
ON
Q
y (p
° O ➢ • (O
.�
rn
to
Cn ��
w
d
O
O
O
Ln
Ail
FA
O
'O
z
D
fN
m
C
C)
m
v
V
r
O
o
0
0
�IV
0
O
L n
S ]a °• -Z
FR/arc
\ ,7
F
774
< �.
m=
\
OJ \
7 9�
`o
?.O
N
�
nAn
z
•
D
O U)
m O
?2O,
Z V al
O =1
n
m
mo
J
A
11n
D
r
0
V
U)
m
m
z
-I
t
Municipality of Anchorage
• Development Services Department
Building Safety Division
On -Site Water and Wastewater Program `
4700 South Bragaw St *A9
P.O. Box 196650 Anchorage, AK 99519-6650
r` • www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051.801.16 HAA #_20
Expiration Date: _Vvz/ cn o
1. GENERAL INFORMATION
Complete legal description Lot 6 Block 4 The Tablelands Subdivision
Location (site address or directions) 23006 Whispering Birch Drive
Current Property owner(s) Spinell Homes, Inc.
Day phone 3445678
Mailing address 1900 Northern Lights Blvd. Anchorage AK 99517
Lending agency Day phone
Mailing address
Real Estate Agent Day phone
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
Four 4
TYPE OF WASTEWATER DISPOSAL:
❑
Individual On-site
❑
Individual Holding tank
❑
❑
Community On-site
❑
®
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given In paragraph 5 by an Independent professional civil
engineer registered In the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water
supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with
valid water samples.)' Certificates are valid for one year for properties served by Class A or B wells or a public water
system. The Municipality of Anchorage Is not responsible for errors or omissions In the professional engineer's
work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-
site water supply and/or wastewater disposal system Is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the Information obtained from the
Municipality of Anchorage files and from my Investigation and Inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of Installation.
Name of Firm Anderson Engineering Phone 522-M3
Address _P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E. Date 012212005
5. DSD SIGNATURE
_4e�f Approved for L_ bedrooms.
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
Additional Comments
Attachments:HAA Checklist y o �opmg
Maintenance�f Wiement�
Septic System Advisory
Well Flow Advisory
Supplemental Engineer's Report
Other
By: k , . A bmt tiQ D— Original Certificate Date: c
(Pw 12M)
A. WELL DATA
Well type —
Date completed —
Total depth ft.
Date of test
Static water level
Well production
Municipality of Anchorage
Development Services Department
Building Safety Division
OnSlte Water & Wastewater Program
47W South Bregaw St
P.O. Box 198850 Anchorage, AK 99519 -SM
www.cl.anchorage.ak.us
(907)343.7904
HEALTH AUTHORITY APPROVAL CHECKLIST
If A, B, or C provide PWSID 0 — Web Log (YIN)
Sanitary seal (YIN) —
Cased to R
FROM WELL LOG
WATER SAMPLE RESULTS:
Coftrm colonlesH00 ml.
Date of sample:
B. SEPTICfHOLDING TANK DATA
Wires property protected (YIN)
Casing height (above ground) in.
AT INSPECTION
R ft
9.p -m. O.P.M.
Nitrate mg.A. Other bacteria colonlesl100 ml.
Collected by:
Tank Type/Material Seoticfliteei
Tank size 1.250 gat Number of Compartments;
Foundation cleanout (YIN) Y Depression over tank (YIN) N
.: = i . r, I
Cleanouts (YM) Y
High water atarrn (YM) Y
Date of pumping Pumper New Construction
C. ABSORPTION FIELD DATA
Date Installed pb2=5 Sob rating (g.p.dJtt= or fe/bdrm)iS 0 System type V YVlde Shallow Tronch
Length 134 ft. Width 5 R Gravel below pipe 4 R
Total depth 01 IL Eftabsorption area +au ft= Monitoring tube X Depression over field tj
Date of adequacy test Results (Pass/Fab) For — bedrooms
Fluid depth in absorption field before test — in. Water added— gai. New depth— in.
Elapsed Time: — min. Final fluid depth — In. Absorption rate x g.p.d.
Any rejuvenation treatment (past 12 mo.) (YM & type) N If yes, give date
D. LIFT STATION
Date installed
'Pump on' level at _ in.
Datum
Size In gallons
'Pump ofr level at _ In.
Cycles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot WA
Absorption field on lot NIA
Public sewer main KFA
Sewer /septic service line WA
ManhoWAccess (YIN)
High water alarm level at in.
Meets alarm d dradt rwMmmw ts9
On adjacent lots MIA
On adjacent lots WA
Public sewer manhole/cleanout WA
Holding tank WA
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 3,5' Property line >' Absorption field 3,S
Water main >10' Water service Ane 3,_10' Surface water MIV
Wells on adjacent lots >2W
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property Ane >17 Building foundation >10' Water main >10'
Water Service line 3,111' Surface water 3,1W Driveway. paftWVehlde storage 4'
Curtain drain _ None Noted Wells on adjacent lots >-2W
F. COMMENTS
G. ENGINEER'S CERTIFICATION (� "' \••
I certify that I have determined thmugh field inspections and V%%,N
review of Munk4pal records that the above systems am in conformance w!!h MOA HAA guidelines In effect on this dateEngineer's Printed Name Michael E Anderson. RE CcDate 812 105r,
HAA Fee $ 57.50 -r 1-1500 Waterer Fee S
Date of Payment -�7 tete of Payment
Receipt Number %,9&40 [_%WSLCS)l VNMReceipt Number
(Rev. 1M
k §tGm}
k moaj D
m0A�$§
emnz2O
# Rk§m\�-Q
} 0 2§§ice
[� 4� o
§ ®2%§
zE
#;&§t® _� m-
\
moP-k� Orn
o(n \ m td
£�2gm
3 iiR32«m X
o n n � r n
k /Ek§/��kkk2
§ \k/\§\kk§d�
En 27�nO�§2§q&/
o n�
on o_
\ � � U)z 0 / &
q m = ® m v#
/ /rri0 CD=// /
�Z
0 6rri
//§\k2\
§�g$�omma�2
�
2
rri
z �>I
O CD
I r-
00 m
o>�
OCU
O W
C/)
C
CD
<
_C/)
O
. Z