Loading...
HomeMy WebLinkAboutTHE TABLELANDS BLK 7 LT 8The Tablelands Block 7 Lot 8 #051-801-40 Municipality of Anchorage Page I 3 or Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SW040494 PID Number. 051-801-40 wm. S inell HomesInc. Wastewater System: Upgrade Addrsu 1900 W. N. Lights Blvd. Anch. AK 99517 ABSORPTION FIELD •r ti rw.ro.aaeao.m 344-5678 Five 5 Sand Filter Bed LEGAL DESCRIPTION Sol R." is D"it. o pn° W° Bbdt LN Suad 2.0 GPD/Ft' 1.0 Ft. 7 8 The Tablelands 0" m p" eptoN eom &Ww wr +1.5 Grow doper 0arlsaN PIPs 7osrMtup Rrgs Saalvl. Ft. FaaddedN d^g' lr Oe 1 FL G"LargN 2-3 Ft. 40 Ft. Well: AWWU Gsw wan 12 rwNn.NM.. DnWln tnLssan trrin Clnblwlan (PmNs, A B. C) T" Depth Cusum Ft. T" tlLorpiwt s 5 2.5 FL Pps MatNIN Ft. Ft 480 Fr ASTM 3034 PVC Drdlr ON. OnIW SINK WON Ls YWAYar' DNs Yq iN; Ft S ineli Homes 2/1-18/2005 YrNd PL.V SN t Cssrp ADws Gourd GVM FI. Ft TANK SEPARATION DISTANCES STEP To Septic Absorption Lift Holding bwrrtvate 1di1w tyn From Tank Field Station Tank Sewert.ine Anchorage Tank 2,000 wd >200' >200' >200' N/A >25' w'wR Steel Three surscswN. >100' >100' >100' N/A LIFT STATION LN Is. >5' >10' >5' N/A �a 250 GN Anchorage Tank/Orenco FoutlNlon >5' >10' >5' N/A T wm•mw N. •Pun, Nr, N Hqn .N. aINTY 42 m 42 m 44 m. cN D. None Noted Pum lAaks a"°d" Ew mspsdwns P.mnrad by Orenco Allied Alaska Electric rrl.Ms 2Re" nsula i n Over Sand Filter Bed. BENCH MARK loulanwplan. Flnlshed Fioor. ALwnwd EN .. 100.0 FL Engineees Stamp • r' Inspections performed by: TLK Dates: 1" 2/1/2005 „49(n L A....��� .ty!} i1�i1 2nd 2/18/2005 Department o Health and Human Services approval P AAL MC, WL E AND!650N iv •.` s No. -.se Or," ••i�4o•�?-r _ Reviewed and approved by Date: oto ��" nta tdvol •4a /� � F1 o wese• 0 E r o CL a d I b S (/) C) zw 004) LiJ J / C M e W 3 0 n .mf —J 3/ c�ia 4 e SS W rn o Q •oF / b. /i W L) oi.J .W dam w /vry / u 7 y Uzi F— O h / N Oma / 5 / o� / emm♦eme, e / N r — — — — — — — — --- ------ .00'OLZ.y .10'ZLeI ,Z6'9%t h�fs.r0.00 N _-- - door avervvs:'o - •o• r"•??I. O ,?b •• • c =��1 v .� de��•Q`t • Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 Onsite Wastewater Disposal System or Well Inspection Report Permit No. SWO40494 TBM = PID No. 051-80140 PRESSURIZED EFFLUENT LINE Fabric 2' Insulatlon Gravel Coarse Sand PROFILE AS -BUILT . .....i... Scde: I" - 10• :� tNICNAEL E. ANDERSON September 6, 2005 Anderson Engineering Attn: Mike Anderson P.O. Box 240773 Anchorage, AK 99524 ELECTRICAL CONTRA CT//VG FAX: (907) 677-7766 Subject: Lfft Station Inspections at properties stated below. This letter is to confirm that the lift station(s) at: • Lot 10, Block 6 —Tablelands • Lot 8, Block 7 - Tablelands were wired by a licensed Journeyman Electrician in accordance with the 2002 National Electric Code requirements. If you would like any further information, please feel free to call our office at the numbers listed below. Thank you. Sincerely, ALLIED ALASKA ELECTRIC, L.L.C. Janette L. Brown, Vice President/CFO cc: file P.O. Box 876310, Wasilla, Alaska 99687 (907) 373-3893 ofe / (907) 232-8687 cell/ (907) 373-3894 fax T'd b69C-CLC (LOG) OT.4100i3 emselu paitlH dbZ:ZO SO 90 daS ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 September 22, 2005 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 8, Block 7, The Tablelands Subdivision Separation Distance Waiver Bottom of Bed to Groundwater Dear On Site Services Engineer: We were recently informed the groundwater may be encroaching closer than 4' from the bottom of the constructed bed on the subject lot. We are therefore requesting a waiver be issued allowing the groundwater to be 2' from the bottom of the bed. An intermittent dosing sand filter was installed on the lot to treat and dispose of the sewage. Operational results obtained over time on this type of system indicate that treated effluent is much cleaner than typical effluent generated in a standard septic system. We have also taken steps to insure that no surface water will flow toward the new bed. We are confident this system with the waiver to groundwater at 2' will not cause contamination to the groundwater. Sincerely, / <�:Jpa_n Michael E. Anderson, P.E. MUNICIPALITY OFANCHORAGE �0 `\ J Development Services Department On -Site Water B Wastewater Program /a O 4700 South Bragaw Street (/ P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Dec 14, 2004 Expiration Date: Dec 14, 2005 Permit Number: SW040494 Parcel ID: 051-801-40 Legal Description: THE TABLELANDS BLOCK 7 LOT 8 Design Engineer: 0014 Anderson Engineering Site Address: 23618 FALLOW CIRCLE Owner Name: SPINELL HOMES, INC. Lot Size: 54679 SO. FT. Owner Address: 1900 W. NORTHERN LIGHTS BLVD, SL Total Bedrooms: 5 Permit Bedrooms: 5 ANCHORAGE. A 99517 - This permit Is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy All construction must be in accordance with: 1. The attached approved design. ❑ Private Well ❑ Water Storage 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907)343,7904 ( 24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By. Date: I 1 )/ -:;u Date: Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. `�J\" moi -44) Permit Number SW Property owner(s) Soinell Homes, Inc. Day phone 3445678 Mailing address (1)1900 W. Northern Ughts, Suite 200 Anchorage, AK 99517 Mailing address Fallow Circle Legal description (Lot, Block & Sub'd.) Lot 8. E Legal description (Section, Township & Range) Lot Size 54,679 SF Acres/Sq.Ft. THIS APPLICATION IS FOR: Code Number of Bedrooms Five (5) Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ afX. 1631 Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. -mi'L 'E Qs-�' (Signature of property owner or authorized agent) Permit Fees: t gLro— Date of Payment t Zl ei1] Receipt Number. 1.5110 (Rev. 12/00) Waiver Fees: Date of Payment Receipt Number. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522.6779 FAX December 9, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 8, Block 7, Tablelands Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer. The owner of Lot 8, Block 7, Tablelands Subdivision intends to construct a five - bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed water service and the proposed septic system along with the alternate site. The subdivision is currently served by the Municipal water system and no conflicts exist between the proposed septic system and wells in the area or septic systems on adjacent tots. Also identified on the plans are drainage arrows indicating the current surface flow patterns. The drainage patterns will be maintained after construction. Test holes placed on the lot indicates silty sand with some gravel in the area of the new absorption bed. The percolation rate for this lense is between 31 and 60 minutes per inch. During our field investigation groundwater was found at approximately 4' below the surface and was recently measured at 3'. We are therefore proposing to place a new 2,000 -gallon STEP tank along with a 40' long by 12' wide intermittent bottomless sand filter. The elevation of the distribution line in the absorption bed will be 1.5' above the existing ground surface. The separation from the highest measured groundwater will then be 4.5'. A minimum of 2' of coarse graded sand will be placed to raise the bed above the existing ground. The ground surface on the lot slopes at minor grades from the east to west and north to south. The new absorption bed will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 200' from the wells serving the subdivision. It will also be L.ot 8, Block T, Tablelands December 9, 2004 Page Two constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 0 m Y 0 Wj' FW' 2 V) C) / /`osf EQ OV1 mo, Q/ g y J 00 SOF J.901 x x q /+ R V4 Q J .ti / � • W y { 3 •€ 9 \` � oLaf� '11753-3 .Z.L9 A '1 , Sl —_-- 1 •00'OLZ� b to, Z-1 ,Z6'99L W./S,f0.00 N ` \ O 1'1 d001 21V8WVS raj W W u H H N LOT 8, BLOCK 7, TABLELANDS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom House Bottomless Intermittent Sand Filter Perc. Rate: 31.60 MinAnch 2,000 Gallon STEP Tank Application Rate: 2 GPD/SF 2' Coarse Sand (See Spec.) Air Supply Line (Anch. Tank) 6" of 3/8" Pea Gravel 5 Bedrooms X 150 GPD/2 GPD/SF (Application Rate) = 375 SF Absorption Area 375 SF/12 LF (Width) = 31.25 LF Bed Length THEREFORE: Construct a 40' Long x 12' Wide Bottomless Sand Filter Bed as Shown Below. Place Distribution Piping at V Above Original Ground Surface. Provide 2" of Insulation and 2' of Cover Over Bed. Maintain 200' Separation From All Wells in the Area and 10' From Water Services. Topsoil and Seed n Monitor Tube 2" Insulation & 2' Cover (Min.) �eotexti abric Over ea GGrave 5 O O O 3/4'PVC Lateral 4 Each) Existing Ground 3/8' Pea Gravel _ � • .,Irk Air Line 18" Below Top of Sand 12' NOTE: Remove Organic Layer and Construct Sand Filter at That Level. Minimum 2' Separation From Bottom of Filter to Groundwater. TYPICAL BED SECTION (NO SCALE) NOTE: Grade Area Surrounding Bed to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 200' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK Dr:PTI I (Rro) 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 8. BLOCK 7, TABLELANDS S/D PERFORMED FOR: SPINFII DATE:- 9/29/2004 PROJECT No•M0490 PARCEL ID.- TECHNICIAN: T. L. KIMBROUGH TEST HOLE # 1 SILTY ORGANICS/OB SLOPE 2 READING WET SILTY—SANDS WITH FINES � 3 PTH OF (INCHES) W ATcn- 4 TEST HOLE PRESOAKED PRIOR TO TESTING: WATER SEEP -1 is LAZ 5 13:10 6 CHARGE 7 2 13:40 g 8.5" WELL COMPACTED DAMP GRAVEL—SILT—SAND 9 MIXTURE W/COBBLES TO 10" RECHARGE GM 10 14:10 30 11 0.5" BOH 12 13 14 15 16 17 18 19 €0 DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) PTH OF (INCHES) INET DROP (INCHES) 9/29/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 13:10 9.0" CHARGE 2 13:40 30 8.5" 0.5" 3 13:40 10.0" RECHARGE 4 14:10 30 9.5" 0.5" 5 14:40 11.0" RECHARGE 6 15:10 30 10.5" 0.5" PERCOLATION RATES 600 (NIIN/INCI I) FERC. }TOLE DIA, 6 gNci1ES) TEST RUN BETWEEN: 4.0 FT. and i.OFT. WAS GROUND WATER ENCOUNTERED? YES IF YES C WIIAT DEPTTI,) 4' DEPTH TO WATER AFTER MONITORING: 3' DATE OF MONITORING: 10/25/04 COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECII ENGINEERING TECHNICAL SERVICE. 1, MICI IAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORATED IN ACCORDANCE WITI I ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 11/2/04 . MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 DrPTI I (rat) 1- 2 3 4 II SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 8. BLOCK 7, TABLELANDS S/D PERFORMED FOR: SPINFI I DATE: 9/29/2004 PROJECT No - M0490 PARCEL ID.- TECHNICIAN: T. L. KIMBROUGH TEST HOLE # 2 SILTY ORGANICS/OB SLOPE WET SILTY -SANDS WITH FINES A�rVZ- 'T,� te S WELL COMPACTED DAMP GRAVEL -SILT -SAND 9 MIXTURE W/COBBLES TO 10" GM 10- 11- 12 011 12 13 BOH 14 15 16 17 18 �0 DATE READING G OSS TIME MINUTES) NET TIME (MINUTES) DEPTH OF WATER (INCHES) NET DROP (INCHES) 9/29/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 13:25 12.0" CHARGE 2 13:55 30 11.375 0.625' 3 13:55 12.0" RECIIARGE 4 14:25 30 11.5" 0.5" 5 14:25 12.5" RECHARGE 6 14:55 30 12.0" 0.5" PERCOLATION RATES 60 (MIN/IVCFI) PERC. HOLE DIA. 6 (INCIIES) TEST RUN BETWEEN: 4.5 FT. and_5,5_FT. WAS GROUNDWATER ENCOUNTERED? NO IF YES @ WIIAT DEPTII? DEPTH TO WATER AFTER MONITORING: 3' DATE OF MONITORING: 10/25/04 COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECI I ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 11/2/04 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 8, BLOCK 7, TABLELANDS SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 2,000 gallon combination septic tank and lift station (STEP) and pressure distribution system. Work also includes the construction of a new 40' long x 12' wide Bottomless Intermittent Sand Filter at the location shown on the attached Site Plan. A minimum of 2' of coarse sand meeting the specification attached must be imported and placed in the filter area. The 6" of pea gravel and distribution piping must then be constructed atop the imported filter sand material in conformance with specifications furnished by the supplier. The distribution piping for the filter must be placed at the elevations shown on the Site Plan to provide a minimum of 4' separation to groundwater. All work must be completed in strict conformance with the manufacturer's requirements for installation of the intermittent sand filter. The new septic tank and sand filter must be constructed a minimum of 200' from the wells serving the subdivision and 10' from any water service line. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANKILIFT STATION INSTALLATION 1. The 2,000 -gallon septic tank/lift station must be constructed by a certified tank manufacturer. Construction shall include an 18" manhole to provide access to the lift station. Lot 8, Block 7, Tablelands December 9, 2004 Page 2 of 4 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 4. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 5. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 6. Final grading over the tank/lift station shall be such that a positive slope exists away from the septic tank. ABSORPTION BED CONSTRUCTION: 1. The absorption bed shall be constructed to the dimensions shown on the design. The bottom of the bed shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 8, Block 7, Tablelands December 9, 2004 Page 3 of 4 MATERIAL SPECIFICATIONS: The lift station must be constructed by a Municipally approved septic tank manufacturer. An Orenco 20 OSI 05 HHF-5 pump is recommended. Anchorage Tank is a recommended supplier for the materials required for this project. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 2. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 3. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernoo, or equal). 4. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 5. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. EQUIPMENT SPECIFICATIONS: 1. Air Supply Line shall be a Wasteflow Emitterline, %" inside diameter from Anchorage Tank. Line shall be insulated with'/" foam pipe wrap inside a 2" Schedule 40 PVC Jacket buried a minimum 3' below the surface. 2. Air Compressor shall be a Thomas Industries Model 5070 as supplied by Anchorage Tank. Compressor shall be located in the garage or crawlspace. 3. A pressure gauge calibrated from 0 to 10 PSI shall be furnished and installed in line with the air line. The gauge shall be mounted in an area which provides easy viewing and is seen on a regular basis such as the entrance to the home. Lot'8, Block 7, Tablelands December 9, 2004 Page 4 of 4 FILTER SAND SPECIFICATION: 1. Material for Filter Sand must be classified as a masonry sand and meet the following gradation: 50% or More Passing the No. 4 Sieve 2% or Less Passing the No. 100 Sieve 1% or Less Passing the No. 200 Sieve INSPECTIONS: A minimum of two inspections are required by Municipal Ordinance. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. ID: 907.277-3715 Anchorage Tank Thursday, August 09, 2001 11:22 AM Page: 6 of 10 Anchorage Tank 6 Welding, Inc. Intermittent Sand Filter SAND FILTER INSTALLATION 1. Excavate a hole where the filter is to be located. Check your engineer's drawings for the depth and orientation of the hole to your site. The hole should be flat on the bottom with a depression in the middle If your system requires a pump basin. If your filter is bottomless, do not compact the soil on the bottom of the hole. Smooth shovel blades in some soils create a compacted surface that will not permit effluent to percolate Into the soil and will certainly cause your sand filter to fail. If yourfilter is gravity or pump discharge, it will have a liner, and a 2" cushion of sand on the bottom of the hole will help protect the liner from penetration of sharp objects. b FEET ONE FOOT LON6ER IAN FILTER DIMENSk DO K= GOWAGT 501L DEPRE55ION FOR FOR BOTTOMLESS/'PUhfi' BASIN FILTERS / (IF REQUIRED) 2. Construct a perimeter support frame from 2x4s and plywood. This frame supports the filter during construction and holds the liner in place, if your system requires one. Treated wood is not necessary as once the system is backfilled and complete, the sand and backfill supporteach other, and the wood can decompose without harm to the system. During construction of the filter (place- ment of the media) it is important to place sand between the frame and excavated earth. All nails or staples must have their sharp ends pointed toward the outside of the filter to reduce the risk of snagging the liner (if your system has one). Received Time Aug. 9. 10:30AM Page 39 ID: 907-277-3715 Anchorage Tank Thursday, August 09, 2001 11:23 AM Page: 7 of 10 Anchorage Tank E Welding, Inc. Intermittent Sand Filter SAND FILTER INSTALLATION Optional Steps. The 30 mil PVC liner unfolds from the center of the filter and draped over the edges of the supportframe. Care must be taken to ensure the liner is in full contactwith the bottom and sides and that no bridging occurs. Pleats or wrinkles in the liner are not a concern. The PVC pump basin rests in the depression in the center of the sand filter. The pump basin must have a PVC or fiberglass bottom to prevent damage to the liner. It's important to verify all dimensions to ensure the pump basin is at the correct height. The pump basin should have 4 inch grommets installed opposite one another to accommodate the inch slotted PVC underdrain pipe. The underdrain pipe is laid flat with the slots pointed upward. If your system contains a pump basin, the underdrain pipe should penetrate the basin 1 to 2 inches. Both ends of the underdrain pipe are capped so any liquid entering the underdrain pipe will fall into the pump basin. If your system is gravity discharge (no pump basin) then only one end of the underdrain pipe is capped while the otherend exits the filter side wall. Any liquid entering the underdrain pipe will be carried out of the filter to a drainfield downstream. 3. Place a level course of 1/4" - 3/8" diameter pea gravel in the bottom of the sand filter. If yourfilter has a liner, water will pond 2" - 3" deep at the bottom and this pea gravel will allow the effluent to flow freely towards the underdrain pipe. The air line can be laid across the pea gravel similar to that shown on page 36. The air line from compressor in the house basement/crawlspace to the sand filter should be 1 /2" high density polyethelene, wrapped in foam, and run inside a 2" PVC conduit for direct burial. This air line will "breathe life" into your sand filter; the warmer the air is, the better. LINE FROM COMPRESSOR, IN HOUSE EMENT OR 6RAYILSPA6E 1/4" — 9/8" m PEA 6RAVEL 176" THICK LEVEL LAYER Page 40 Received Time Aug. 9. 10:30AM ID: 907-277-3715 Anchorage Tank Thursday, August 09, 2001 11:24 AM Page: 8 of 10 Anchorage Tank 8 Welding, Inc. Intermittent Sand Fiher SAND FILTER INSTALLATION 4. Filter sand must be placed and compacted while damp. If the sand is not damp, it will not compactwell and settlement may cause dislocation and breakage of the distribution laterals above, creating a real mess; wet the sand when necessary! The sand layer is approx. 24" deep and the surface needs to be level. This is best accomplished with a 6' carpenter's level and a straight edge. 5. Place a 3" layer of 1/4" - 3/8" pea gravel on top of the compacted sand, disturbing the sand as little as possible. This pea gravel serves to support the distribution system and keep sand from eroding under the action of the effluent being applied. Snap on an orifice shield over each 1/8" diameter hole in the laterals. Orifice shields are required to prevent the orifices from being blocked by pea gravel resting on the PVC laterals, and they direct the flow of effluent downward into the sand filter in an even distribution. After the laterals are installed and a pressure test performed, add three more Inches of pea gravel. Page 41 Received Time Aug. 9. 10:30AM 0: 907-277-3715 Anchorage Tank Thursday, August 09, 2001 11:25 AM Page: 9 of 10 Anchorage Tank 6 Welding, Inc. Intermittent Sand Filter SAND FILTER INSTALLATION Optional Steps. The liner's PVC boot permits a watertight penetration of the liner for the transport pipe bringing effluent to the filter from the S.T.E.P. tank. In the event high ground water would reach this level, the boot would prevent infiltration. When installing boots, especially the one for the underdrain pipe, the manufacturer's installation instructions must be followed exactly, being sure to orient the boot so the clamp is outside the sand filter. 6. Fllterfabric is placed over the final course of pea gravel. The filterfabric keeps soil, silts, and fine grained materials from moving down into the sand filter, at the same time allowing air and water to pass freely. It is important to use the filter fabric that came with your sand filter, as other fabrics may be so dense that air and water movement are impaired, causing your sand filter to clog and tum anaerobic (smelly). 7. At the end of each lateral, there is a sweeping 90 degree upturn with a PVC ball valve. These valves are used for annual flushing of the system, and for performing squirt tests. The first squirt test will set a benchmark for monitoring yoursystem's performance. To perform the first squirt test, temporarily remove the PVC 90 degree elbows (downstream of the PVC ball valves) and replace them with PVC caps with a 1/8" diameter hole drilled in each top. Turn on the dosing pump in the S.T.E.P. tank. Be sure there are no plugged orifices (you'll see and hear water spraying under each orifice shield) and measure the height of the fountain of water spraying out of the cap at the end of each lateral. The water should be squirting around 5 feet high. Mark the exact squirt height of your system inside the control panel and in this manual so you won't forget It. Page 42 Received Time Aus• 9. 10:30AM ID: 907,277.3715 Anchorage Tank Thursday, August 09, 2001 11:26 AM Page: 10 of 10 r, Anchorage Tank 6 Welding, Inc. Intermittent Sand Filter SAND FILTER INSTALLATION 8. Replace the squirt test caps with the 90 degree elbows, and keep the caps for annual mainte- nance use. You are now ready to begin backfilling over the sand filter. The soil cover must be loamy -sand. Its purpose is to provide insulation against freezing, to allow free movement of airto the sand filter below, and to prevent odors from escaping the sand filter and spoiling you daughter's backyard wedding reception. Planting grass over the sand filter is very beneficial. FILL SPACE r Apr„n,_ WITH PACKIt15 .�, ^WPM Wn - 9. Carefully position the flushing valve cleanout enclosures (they are green and look like flower pots) over the PVC ball valves so the enclosure lid is slightly above grade. It is a good idea to place packing peanuts or some other removable insulation material inside these enclosures. Every dos- ing cycle sends pressurized effluent up to the valve, where it can get mighty cold near the surface in the winter, then the chilled effluent drops back down into the sand filter. 10. Complete backfilling. Your sand filter should have a minimum of 2 feet of cover, but refer to engineering drawings as theysupercede information in this manual. Plant grass and you're finished. Page 43 Received Time Aug. 9. 10:30AM Lys elcc /k�_?6LVV& 2 - Municipality Municipality of Anchorage Development Services Department Building Safety Division Onsite Water and Wastewater Program ' 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-801-40 — _ - -- HAA# Expiration Date: .1 r­1/bar r, 1. GENERAL INFORMATION Complete legal description _ Lot S. Block 7. The Tablelands Subdivision Location (site address or directions) _ 23618 Fallow Circle Current Property owner(s) Soinell Homes, Inc. Day phone .344-5678 Mailing address 1900 Northern Lights Blvd. Anchorage AK 99517 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. . 2. NUMBER OF BEDROOMS: Five 5 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ® Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given In paragraph 5 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system ls(are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the Information obtained from the Municipality of Anchorage files and from my investigation and Inspection, the on-site water supply and/or wastewater disposal system Is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of Installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorages AK 99524 Engineer's Printed Name Michael E Anderson P.E. Date 9/19/2005 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: HAA Checklist X Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other By: Original Certificate Date: `r (n«.12W) Municipality of Anchorage Development Services Department `•: Building Safety Division OnSke Water R Wastewater Program 47W South Bregaw St P.O. Box 198850 Anchorage, AK 99519.8850 www.cLanchorageAk.us (907) 3437904 HEALTH AUTHORITY APPROVAL CHECKLIST Wen type _ If A, B, or C provide PWSID tf _ Well Log (YIN) Date completed _ Sanitary seat (Y/N) _ Wires properly protected (Y/N) Total depth ft Cased to ft Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level Well production WATER SAMPLE RESULTS: R Conform colonlesH00 ml. Nitrate mg.A. Other bacteria Date of sample: Collected by: B. SEPTIWHOLDING TANK DATA R 9- p.m-colonies/1 Tank Type/Material _ STEF tool Date installed 2/1/2005 Tank size 2.000 gal. Number of Compartments I Cleancuts (YIN) Y Foundation cleanout (Y/N).y Depression over tank (YM) )g High water alarm (Y/N) Y Date of pumping Pumper Mew Construction C. ABSORPTION FIELD DATA 100 mi. Date Installed Son rating (g.p.dA? or felbdrm) 2.0 GPD*SF System type Dosing Sand Fifter Length 40 It Width 12 R Gravel below pipe 1 tt. Total depth g it Eff. absorption area 011? Monitoring tube I Depression over flekl U Date of adequacy test I Results (Pass/Fall) For _ bedrooms Fluid depth In absorption field before test _ in. Water added_ gal. New depth_ In. Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >=d. 9•P• Any rejuvenation treatment (past 12 mo.) (Y/N S type) _ N If yea, give date D. LIFT STATION Date installed 211/2005 Size in gallons 250 Manhole/Accesa (YM) Y 'Pump on' level at 43 in. 'Pump oft level at 4Z in. High water alar level at 44 in. Datum Bottom of Tank Cycles tested New Constructlon Meet& alarm ti circuit requirements? X E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankfift station on lot NIA Absorption field on lot N/A Public sewer main N/A Sewer /septic service line NIA On adjacent We NIA On adjacent lots NIA Public sewer manhole/deanout NIA Holding tank NIA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >B Property line >9 Absorption Belt >S Water main >10' Water service Ilne >10' Surface water >100' Wells on adjacent kts >200' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Properly line >10 Building foundation >10' Watermain >110' Water Service tine >19 Surface water >100' Driveway, parka Vfthlda storage >B Curtain drain None Noted Wells on adjacent kots >200' F. COMMENTS G. ENGINEER'S CERTIFICATION I cenily that I have determined through field kapecflons and ° 49th sem► �` '� review of Municipal records that the above systems are in conformance with MOA NAA guidelines in effect on this dale. _.......... e...„._. NMNA . c amumr� Engineer's Printed Name Michael E. Anderson. P.E. �i�',ooT�� Data 9119/2005 HAA Fee $ 'S S7 Waiver Fee $ Date of Payment 9 -/f—o> Receipt Number 1 Y �r ✓��_ (Rev. 12MM Date of Payment Receipt Number •** • !a%* • ,.fie° :*s*, ;O"% �I '`"°yo 2 • � ��d mO 014mN D N iorn-9�C N Z�m��� I m m o C) w O u D m 6- C_ z i co --iF u+ _ -r-I ID z f Ln men N Z D N m z b o m z m_ oZ Dmov<mv)oom m o NZ'om�-IDmm - 2 CO O +' ZcoOoNmfTl= -C L7 r- o A m oo-�O tmnzmz M m 0M0rn 0U) �� Q z m N o�o�mm0 -i Z-(0 0T =10�po- v ANyoNoomm D � fri =d C ;2 m0 i c 0 m ZzgovRZ*701< vmip��zOrm�Dzom ovzm P o p > O O = �D• �n m O ill SAMBAR LOOP r- 0 2 m ►I CIO w O i L I ADVANCED WASTEWA'IF.R T1ti7ATMh MKMORANDUM ON AND THIS MEMORANDUM OF UNDERSTAN 'qday of�of20 by: herein the "OWNED" end the Municipality of "MUNICIPALfTY." In consideration of the nn parties to this Msmorandu rt of Uuderslaadin a ]. ADVANCED WASTEWATF TRE! SY..MM MA. ..MANCE AND �1 JO trade and ent rod into as of thio n betwaa I snV-6L h • vviv ehorav, beuin the covenant: contained basin, the SYSTEMS. Municipality grants permission to Owncr to tntitize and *rase anAdvan=d Wastewater Treatment System (AW WTS) dc=ibed X^7--nMT #T— Io"ted. at for 1i, $ coup 7, 7;a r Tena c tr . Ancbotne. Alaska. 2. Definitions. A. Alteratlan. Any change to the inehrtrs the installation or remov not included in tbo ori&A constr perf=ing any alterations to an A Wasmwaret Disposal System Coo pursmot to Ancborag: Municipal B. Certificate of On -Site Syaams Municipality of enciaft water and The time of property sale and title i or f uxction of an AW WTS that tiny parts, components or pieces permit and design Prior to IS the owner mutt obtain a on Permit from the Mmicipality (hereiatrlter, "AMC 15.65. An approval by the disposal systems giVen at in sc mrdaoce with AMC 15.65. £0'd sers Z99 L06 1S3 -IU38 UISIA IAIN30rl8d 0£:0 5002-9Z-d3S •u SM. -• These approvals eertlfY that the systems ate odcgnate for the homes that tl:ey support and meet the codes that were is place at the time of system construction. C. DamaEe. Any man-m.rdc or tubcal Fltuige in a system that would inhibit the system hors performing as dengrted. D. Msintcaance and Repair. The scheduled and as needed rcplwtment of existing parts, components and 'of an AW WTS that w= included in the original design which would 1110u, the AW WfS to continue to perform as designed. E. ywmit(Coas(ruction) AnOvSlteWwwwatcrDisposalSystem Construction permit as defined by AMC 15.65. F. permit (Opmting) An AdvancedWamwater Treatment Syst.^m Operating permit. An annual permit,, issnod by the Municipality, that allows the Owner to operarc an AW Wn, tion meeting ill the requitnmeau of ibis amt, the a:tions of Operating pemcit, the requirements of the On -Sine Wastewater System Construction permit sad all relevant provisions of AMC 15.65 3. Ea Owner shall pay to Municipality an annual fee of o' (S_D .00). payable on or Wore the issuance of the oporatimg permit and annually thereafter. Ibe annual foe Is due on or before the annivcrsnry date of the approval by the Municipality of installed system. 4. berm ,be U rm of this Memorandum of Understanding shall be for the life of the AW Wf'S. VO'd 59VS Z99 406 1S3 10321 UISIA 1U11N3anad 0£:£T SOOZ-9Z-d3S The tam begins on the date of spprovei by the Municipality of the insallyd system and shall continue while the AW WTS system is in use �r opmdoml or until the property is sold or title is ttansf+ued by own and a new cetti6cate of On -Site approval is issued to the new ow= or trsnsfast of the property. S. Owner agrees not to make M alterations, removal of parts or ad¢ dons to the AWarI'8 without a n Cortstnaction Permit Ecom the Municipality. 6. DWWn ante and Repairs A. ?hrougbouc the term of this Maaorandum of Uadeisraoding, the Owner shall i malnrain AW W 'S is good repair. In addition, kit sh111 be the responsibility of the Owner during the tam of this Memorandum of Understandin& and any extension or rencwale dxceof, at the owner's sole expense, to pay for any and all: (1) repWs), (2) meintmance, (3) Austzoent(s), (4) replaeerneot cosa, and (S) insroction costs. Further, Owner agrees to Comply will all applicable ordinance, laws, rcgilations, rules and orders for the AWWIS. B. Owner agrees to provide the Municipality a:,wtium schedule of routine maintenance and repairs wtdch have been perfgrmed on the system pursuant to the tams and eooditions contained in tba Owner's AW%rn Operating Permit his scberiule shall be submitted to the Municipnht havu-11Y upon the reaewal of the permit. 'Ile sebedule of mainttance and repair eontaincd in the Owoer's AVWV15 Operating P K%• o 0 Permit !s: C. Owner acknowledges that the fine schedule for failing to tnairnain end repair an AW W M are codified in AMC 14.64. S0'd Saps 29S L0G 1S3 IU38 UIS1l1 1011N3anad 1£:£T 5002-92-d3S D. O«na agrees that only maimewmeq cepa Municipality will inspect and make ttny nates Alterations to the System E Owacr agrees to great the Municipality m AW WT5 upon 24 bees written notice. F. Owner agrees that any We or transfer of ti without a rtew Catifieate of On -Site Systems G. Owoa agrees that the Wevem provisiaw for AWWTS is the irovemnox professiorul N tnaiutanance and repair of the Owner's AWA 7. >'wiThe failure of either party at my Memorandum of Unde+atand erg shall in m eertUied by the - .occas to test and inspect the the property will not ocarr standard specification guidebook for toe cous=tiom to enforce a provisioa of this asttame a waiver of the provisions, nor in Say way affect the validity of the Mewori�ndm of Understanding or any part hereof; or the ri& of such party thereafter to circ tach and every provision hereat l S. Arnendareat. � A. This Mcmormdum of Understanding shall o kly be amended, modified or changed by a writiay, executed by authorized represmw vs of the parties. with the same formality of this Maxwracarlm be attached to this M=xwandw ss exocatcd and ouch writing shall as an amendmem B. For the purposes of any amcndmmt modificl'oa or change to the terms and conditions of tris contract the oaly authorized r4mwentatives of the parties am: I I 90'd 58D5 295 L06 1S3 IUM UISIA "ki11N3GMd t£:£t 5002-92-d35 LO'd -rdi01 i Owner: ay r,j .1. Krn . L.V'% da k:tn 1, Anchorage: F11as1Agu& OZ= C. Any attr npt to amend, modify, of change this contract by chber an umwtborized representative or unautborizeq means shall be void. 9. Jurlsdirfien: Choice of Lttw. Any civil actionarising L'om ibis Memonm anduof Understanding shall be bro*d in the Superior CoIrt for the Third Judicial District of the Stare of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and i obligations of the parties under this Memorandum of Understanding. 10. Sersrabft. Any provisions of this Mefamxandurn of Uadcrstaadiag detrred invalid by a court of eotnpeteAt jurisdiction shall not invalidate the remaining provisions of she M=Qmduorn of Undcrstand ng., 9-Rr4c� jl�� r//l, � Date: a 1 t14,0 10- STATE OF ALASKA THIRD JUDICIAL DISTRICT By: : Tim: Dau:' The fomsoiog insQu ncat was acltinowledscd before me thls2 7 20uy ;bfvr f/ ?/noplo _,theA10{^ <rti on belutf of the Municipality of Anebm NOTARY PUBLIC FOR ALASKA My Commission expires: rosy Commission E4*98 October 10, 2008 day of.c•>'7c lf% V of rA /lrn,!yra- my -� LO'd Set's Z9s 106 1S3 -rH3b UISIn -Vti11N3Qn 8d 1£:£1 5002-92-d3S