Loading...
HomeMy WebLinkAboutTHE TABLELANDS BLK 8 LT 12 Onsite File The Tablelands Block 8 Lot 12 #051 - 801 - 52 Municipality of Anchorage Page 1 of 3 Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage,AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW040363 PID Number: 051-801.52 Name. Wastewater System: New S sine!! Homes Address: 190 1900 W. Northern Lights, Ste. 200 Anch.,AK 99517 ABSORPTION FIELD Phone: Number of Bedrooms: 5' Wide Trench 344-5678 Four 4) Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION .45 GPD/Ft2 6 Ft. Block: Lot. Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 8 12 The Tablelands 2 Ft. 4 Ft. Township Range: Section: Fill added above original grade: Gravel Length: 2-3 Ft. 134 Ft. Gravel width. Number of lines Distance between lines: Well: AWWU Water System 5 Ft. 2 10' Classification(Private,A,B,C): Total Depth: Cased to: Total absorption area: Pipe Material: Ft. Ft. 1,340 Ft' ASTM 3034 PVC Driller: Date Drilled: Static Water Level: Installer: Date Installed: Ft Pisano's Dirtworks 4/7-8/2005 Yield: Pump Set at: Casing I eight Above Ground: TANK GPM Ft. Ft. SEPARATION DISTANCES Septic To Septic Absorption Lift Holding •ubliGPrivate Man rtaclurer. Capacity in Gallons From Tank Field Station Tank Sewer Line Anchorage Tank 1,250 Material: Number of Compartments: Well >200' >200' N/A N/A >25' Steel Two(2) Surface Water >100' >100' N/A N/A LIFT STATION — NONE ON LOT Size: Manufacturer: Lot Line >5' >10' N/A N/A Gal. 'Pump on'level at: ''Pump off'level at: High water alarm at: Foundation >5' >10' N/A N/A in in. in. Pump Make 8 Model Electrical Inspections performed by: Curtain Drain None Noted Remarks BENCH MARK How Splitter Valve Placed to Assure Even How. Location and Uescnption. Finished Floor. Assumed Elevation: 100.0 Ft Engineer's Stamp �''�� `v��i Inspections performed by: T. Kimbrough Dates: 1st 4/7/2005 % : '1 9 t o ��•�'� �0 2nd 4/8/2005 • • `•MICHAEL E. •ANDERSON G W g Department of Health and Human Services approval t6-3:.• .,. NO. CE-4381 �_� Reviewed and approved by: k/Y)lr� �,z, Date: C�Z g ♦••4t,(Rev.10199) co .ROL ss ��:��• .45e.. pro - i c----or 1-07 ,n,� efi c Iliszssits• Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: SW040363 PID No. 051-801-52 THE TABLELANDS SUBDIVISION LOT 12, BLOCK 8 40,005 S.F. s 72,52 37.4-- 297.52, co co N Lo Og/ ! M1 M2 I4 --�-- r Ov oravE /z R S1 / '52 / Four / / cn oBedroom " '� O Home IO cn 3p'M4 I h rn I Q C6 oi C7 GRAva DRNE I N CO 0-4 [.'r) I I A B S 81'03'42'E 256.21' I S1 18.2 36.9 S2 23.7 37.5 SV 31.1 38.0 C4 32.9 55.4 C5 49.4 65.4 • s alii�/., M1 31.9 55.2 •••.-\_-. M2 48.1 63.7 :• :..• ♦♦••• C7 71.0 25.7 49th -. •` PLAN AS - BUILT P• � � ,, MICHAEL E. ANDERSQI' � •1cr Na, cE-4381 tii SCALE 1' = 50' ♦ ��.L-�;: • • • • ♦•• FESS1 ••• 1-iaaaailklis Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655-343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: SW040363 PID No. 051-801-52 TBM = 100.0 7.78 6,43 6,08 [5.68 > > cu co > U c4 (4 U U DECK f 1,250 Gallon D / Septic Tank 91,0 90,9 _ 0,75 0,15 0,48 r, v = I U f H F U 96.55 - - 93.32/ - "-- / 1/ Geotextile Fabric =_—.. —/-- � 88.93 88,71 Dralnfleld Rock In u x 77,2 f1/40 97.16 - - 92.15 - - - / / 85.07 / Geotext le Fa r c — 88.88-7 �89.09 Dralnfleld Rock voisliolUilin e-\ •\-8 ..17fv 4,87 84,86 A ° 49th :*•*t A j1/i11eliti... f P O F I L E AS 3 U I L T IN..MICHAEL E. ANDERSON •♦ No. CE-4381 •1- Scale: NONE ..- ..L-(7P''... : I2004-25 THE TABLELA\ DS SURD VISIO \ . LOT 12 , 3LOC < 8 40,005 S.F. S 25231.e 291.52. in co N (Ni cN p 94 8, PO ti�°4 X6'0. / 'n S '2)1`�4,6, / 0 O GRAVEL DRIVE / 0 / ,'N / Z ••• ^ / • / SEPTIC SYSTEM / / / W p EXISTING Li c5 BUILDING II ,n O I '' 30' ---iO I - c7) IQ • a> CO GRAVEL DRIVEI N 1 "— 40 ' PoII atiJ _ h a S 81'03'42"E 256.21' 119.7' AS — BUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE GASTALDI LAND PROPERTY DEPICTED ABOVE AND THAT NO •Ialiii•41 ENCROACHMENTS EXIST EXCEPT AS INDICATED. ... OF 4 N SURVEYING, LLC IT IS THE RESPONSIBILITY OF THE OWNER TO • Q ••""••.••.45, .� JEFF A. GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, ;'� • 4726 WEST 88TH AVENUE COVENANTS OR RESTRICTIONS WHICH DO NOT i *: 49TH •:* 1 ANCHORAGE, ALASKA 99502 APPEAR ON THE RECORDED SUBDIVISION PLAT. • • PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA • •. Jeffery a Gastoldi �► GRID DATE HEREON BE USED FOR CONSTRUCTION OR FOR aO'O� t' Al ESTABLISHING BOUNDARY OR FENCE LINES. •O'13.1; •. LS-609 1 s^1� ♦ NW 1559 7/8/2005 ..Pap•.........•'6`' .• ANCHORAGE RECORDING DISTRICT, ALASKA •/ 5 1 �walks' . FB 05-05 JoeTLo128 NOTE: NO CORNERS SET THIS DATE. Permit Number: SW040363 MUNICIPALITY OF ANCHORAGE i 11 IV J� Development Services Department Onsite Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Aug 26, 2004 Expiration Date: Aug 26, 2005 Parcel ID: 051-801-52 Legal Description: ,THE TABLELANDS SUBDIVISION BLOCK 8 LOT 12' Design Engineer: 0014 Anderson Engineering Site Address: NHN SAMBAR LOOP Owner Name: SPINELL HOMES, INC Lot Size: 40005 SO. FT. Owner Address: NHN SAMBAR LOOP Total Bedrooms: 4 Permit Bedrooms: 4 EAGLE RIVER. AK 99577 - This permit is for the construction of: ❑✓ Disposal Field ❑d Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. Maximum depth of absorption trenches shall not exceed 7 feet below original grade. Received By. Issued By: '_ Date: Municipality of Anchorage • Development Services Department Building Safety Division Onsite Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWERIWELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. m i' wx- 52- Permit Number SW Property owner(s) Spinell Homes, Inc. Day phone 3445678 u�in address Malting address Legal description (Lot, Block & Sub'd.) _Lot 12, Block 8, Tablelands Subdivision Legal description (Section, Township & Range) Lot Size 40,005 SF Acres/Sq.Ft. THIS APPLICATION IS FOR: Code Number of Bedrooms Four(4) Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ hi;If--j7.%IT t•T•7:yirJt:14 Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: a Li (0 U Waiver Fees: Date of Payment F)j t q 1Date of Payment Receipt Number. 56g4tp �� p� Receipt Number. (Rev. 12/00) c�. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX August 17, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 12, Block 8, Tablelands Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 12, Block 8, Tablelands Subdivision intends to construct a new four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is served by a community water system and no conflicts exist with adjacent septic systems or wells. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The water service line is also shown. The current drainage pattern along with spot elevations are identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. A test hole recently placed on the lot indicated silty sand and gravel in the area of the absorption trench. The accepting soils were tested and found to have a percolation rate of 30 minutes per inch. No groundwater was found In the test holes during placement and none was noted during the monitoring period. Our design includes the placement of a new 1,250 -gallon septic tank along with 2 - 67' long by 5' wide by 4' effective depth absorption trenches to collect and treat the sewage generated in the house. The bottom of the trenches will be 6' below the surface. The distribution pipe will be 2' below the surface. A minimum of 3' of cover will be placed atop the trenches and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at shallow grades from east to west as shown on the Site Plan. The absorption trenches will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service Lot 12, Block 8, Tablelands August 17, 2004 Page Two proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, A j" Michael E. Anderson, P.E. Attachments W���Aam WCHAEL E. ANDERSON \. No. CE -4381 l N 0(r07'59*W 172.65' SAMBgR loo `\ F— D O co —� F— m r— > to z N o; (ACC) C/) N in r Cil O (n C)C /\ a) 00 <_ Cf) O LOT 12, BLOCK 8, TABLELANDS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House 5' Wide Trench System Perc. Rate: 30-60 Min./Inch 1,250 Gallon Septic Tank Application Rate: .45 GPD/SF 4' Drainfield Rock 4 Bedrooms X 150 GPD/.45 GPD/SF (Application Rate) = 1,333.3 SF Absorption Area 1,333.3 SF/5 SF " .5 (Red. Factor) = 133.3 LF Trench Length THEREFORE: Construct 2 - 67' Long x 5' Wide x 4' Effective Depth Absorption Trenches. Flow Line Elevation in Trenches to be 2' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. Provide 2" of Insulation and 2' of Cover if Necessary. Place a Flow Splitter Valve to Insure Even Flow to Each Trench. 1'6" N. 4'0" Natural Backfill 5' Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SECTIO"' (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 10' Separation From Water Services in the Area. Minimum 100' Separation From Surface Water or Streams. DEPTI I (@cl) 1 2 3 4 5 6 7 8 9 I 1 1 1 1 1 1 I 2„ MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION. LOT 12, BLOCK 8, TABLELANDS S/D PERFORMED FOR: SPINFI I DATE; 8/3/2004 PROJECT No --M0466 PARCEL ID,/j TECHNICIAN: T. L. KIMBROUGH TEST HOLE # 1 SILTY ORGANICS/OB SLOPE SILTY—SANDY—GRAVELS GM ism 0% SITE PLAN CUpa KEY 1N2 TH1 0 0 WAS GROUND NATER ENCOUNTERED7 NO IF YES (g WHAT DEPTH? D%. DEPTH OF MATER AFTER MONITORING: NONE DATE OF MONITORING: DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH OF (INCHES) NET DROP (INCHES) 8/3/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 8:45 12.0° CHARGE 2 9:15 30 10.75" 1.25" 3 9:15 12.0" RECHARGE 4 9:45 30 11.125" 0.875" 5 9:45 12.0" RECHARGE 6 10:15 30 11.25" 0.75" PERCOLATION RATE:31 .3(AIIN/INCI I) FERC. HOLE DIA.6(INCHES) TEST RUN BETWEEN: 4.5 FT. and 5.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORDIE-D BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: DEPTH (kcp 1 2 3 4 5 6 7 8 9 1 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 12, BLOCK 8, TABLELANDS S/D PERFORMED FOR: SPINFI I DATE: 8/3/2004 PROJECT No M0466 PARCEL ID,y TECHNICIAN: T. L. KIMBROUGH TEST HOLE # 2 P77=1 SILTY ORGANICS/OB SLOPE POORLY GRADED SILTY—SANDS SP SILTY—SANDY—GRAVELS GM [*em 0% SITE PLAN CURB KEv TH2 TH1 0 0 Y ti SEE FUTUR^ AS1ULT WAS GROIND NATER ENCOLNTE-RED? NO IF YES Ei• WHAT DEPTH? O% DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING: P'I"�^^�• DATE READING GJOSS TIME MINUTES) NET TIME (MINUTES) DEPTH OF WATER II (INCHES) NET DROP (INCHES) 8/3/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 8:50 12.0" CIIARGC 2 9:20 30 10.5" 1.5" 3 9:20 12.0" RECHARGE 4 9:50 30 10.5" 1.5" 5 9:50 12.0" RECHARGE 6 10:20 30 10.5" 1.5" PERCOLATION RATE:20 (MIN/INCII) PERC. IIOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4.5 FT. and_,5_5_FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: DEPTH (15=0 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION. LOT 12, BLOCK 8, TABLELANDS S/D PERFORMED FOR: SPINFII DATE: 8/3/2004 PROJECT No= M0466 PARCEL ID,#• TECHNICIAN: T. L. KIM13ROUGH TEST HOLE # 1 SILTY ORGANICS/OB SLOPE COMMENTS: SILTY—SANDY—GRAVELS GM 9mi SITE PLAN CURB KEY 1H2 TH1 0 0 Y WAS GROUND NATER ENCOUNTERED° NO IF YES (�4 WHAT DEPTH' 0% DEPTH OF HATER AFTER MONITORING: 13.5' DATE OF MONITORING: TEST HOLE PRE SOAKED DATE READING G OSS TIME MINUTES) NET TIME (MINUTES) DEPTH OF WATER (INCHES) NET DROP (INCHES) 8/3/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 8:45 12.0" CHARGE 2 9:15 30 10.75" 1.25" 3 9:15 12.0" RECHARGE 4 9:45 30 11.125" 0.875" 5 9:45 12.0" RECHARGE 6 1 10:15 1 30 1 11.25"10.75" PERCOLATION RATE•31.3 (mmINCII) FERC. TOLE DIA. 6 INCIIES) TEST RUN BET%VEEN: 4.5 FT. and -5 -5 -FT. TO TEST. TEST PERFORb1ED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT TI IIS WAS PERFORMED IN ACCORDANCE WITI I ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTIONS LOT 12, BLOCK 8, TABLELANDS S/D PERFORMED FOR: SPINFII DATE: 8/3/2004 PROJECT No -•M0466 PARCEL ID -u• TECHNICIAN: T. L. KIMBROUGH DEPTH TEST HOLE # 2 (rap I SILTY ORGANICS/OB SLOPE 2 3:`;': : POORLY GRADED NET TIME (MINUTES) Dy ATER F (INCHES) SILTY—SANDS 3 *` :: SP 4 1 8:50 5 12.0° CHARGE 6 2 7 30 10.5" 1.5" SILTY—SANDY—GRAVELS 8 9:20 GM 9 RECHARGE 10 11 12 13 14 15 16 17 18 19 [*ON O% TE PLAN CURa KEY TH2 TH1 O 0 Y S== FUTUR_ AS301-T WAS GROUND NATER ENODUNTERED' NO IF YES (a WHAT DEPTH^ 0% DEPTH OF NATER AFTER MONITORING: NON[ DATE OF MONITORING: DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) Dy ATER F (INCHES) NET DROP I (INCHES) 9/3/04 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 8:50 12.0° CHARGE 2 9:20 30 10.5" 1.5" 3 9:20 12.0" RECHARGE 4 9:50 30 10.5" 1.5" 5 9:50 12.0" RECHARGE. 6 10:20 30 10.5" 1.5" PERCOLATION RATE 2�(N1I J/fNCII) FERC. HOLE DIA• 6 (NCEIES) TEST RUN BETWEEN. 4.5 FT. and 5.5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR To TEST. TEST PERFORMED BY VETECEI ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND A1UNICIPLE GUIDELINES IN EFFECT ON THIS DATE: MUNICIPALITY OF ANCHORAGE Efwfmpqnfou!Tfswjdft!Efqbsunfou Qipof;!!):18*454.8:15 Po.Tjuf!Xbufs!'!Xbtufxbufs!Tfdujpo !!!!!Gby;!!):18*454.8::8 Dfsujgjdbuf!pg!Po.Tjuf!Tztufnt!Bqqspwbm PTD372375 80803138 Parcel ID 162!.912.63 Expiration Date: Legal description UIF!UBCMFMBOET!CML!9!MU!23 Site address 33635!TBNCBS!MPPQ Current property owner(s) !IPINBOO!FSJD!S!'!NJDIFMMF Y5 The On-site system(s) is/are approved for bedrooms Conditional approval forbedrooms, with the following stipulations: Comments or conditions: Op!dpnnfout tffubolbewjtpsz Curtis Townsend 803403137 By:Original Certificate Date: This Certificate of On-Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Service Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's submittal. ATTACHMENTS: !!!!!!Y COSA ChecklistWell Flow Advisory Absorption Field AdvisoryNitrate Advisory Tank Age Advisory Arsenic Advisory Other MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 COSA Application_Apr2025.doc Certificate of On-Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. Complete legal description Location (site address) Current property owner(s) Day phone 2. ON-SITE SYSTEMS SIZED FOR BEDROOMS 3. TYPE OF WATER SUPPLY: Private Well serving # dwelling units Other Non-public well as regulated by MOA Water Storage Community Well or Public 4. TYPE OF WASTEWATER DISPOSAL: Private Septic Private Septic serving 2 dwelling units Holding Tank Community Septic or Public Sewer 5. SEPTIC TANK: Steel Plastic Concrete Fiberglass Age ______ - See advisory if steel or fiberglass older than 20 years 6. ABSORPTION FIELD: AWWTS Bed Deep Trench Wide Trench Seepage Pit Waiver request for: Distance: Expedited review requested: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ Waiver Fee $ Date of Payment Date of Payment COSA # Waiver # COSA Checklist_May2025.docx COSA Checklist Legal Description: THE TABLELANDS BLOCK 8 LOT 12 Parcel ID: 051-801-52 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA - PUBLIC &/OR CLASS “A” WATER Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank 49” Date of pumping 7/7/26 Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. DISPOSAL FIELD DATA Which system tested (date installed) 4/8/2005 ALL standpipes present per record drawing Total measured depth from grade 11.6 ft (max) Measured depth to pipe invert from grade 4.5 ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective. (ED) If not, state depth into effective 3.8’ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 7/7/26 Results Pass East & West Trench Fluid depth prior to test 27 / 0 in Water added 600 gal New fluid depth 27 / 5 in Elapsed time 1440 min Final fluid depth 27 / 0 in Absorption rate 600 gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 48 in (MOA 4’ ED) Effective depth used 27 / 3 in (Final Fluid Depth) Effective depth (ED) remaining 21 / 45 in Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots, visual observations, MOA records & appears the West Trench is missing 3 inches of ED and East trench monitoring tube appears to have 4’+ of ED. Injected 300 gallons into each trench. COSA Checklist_May2025.docx E. SEPARATION DISTANCES From Well on Lot to: (Please enter distances if less than required) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Disposal Field on Lot > 100’ Yes if No ft Neighboring Disposal Fields > 100’ Yes if No ft Sewer Line/Main > 100’ Yes if No ft Sewer Manhole/Cleanout > 100’ Yes if No ft Sewer Service/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Disposal Field(s) on Lot to: (Please enter distances if less than required) Tank to Foundation > 10’ Yes if No *5+ ft Field to Foundation > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main/Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS *Met code at time of install. G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 07/20/2026 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 07/20/26 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 907-343-7904 On-Site Water and Wastewater Section Fax: 343-7997 www.muni.org/onsite Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519-6650 * www.muni.org Septic Tank Advisory Certificate of On-Site Systems Approval # OSC261264 Subdivision: THE TABLELANDS Block:8, Lot: 12 The septic tank for this property is 21 years old. The average life of an asphalt coated steel septic tank is 20 years. Typical replacement costs are $15,000 or more, not including engineering, surveying, MOA permitting fees or site restoration. Steel septic tanks utilizing "Coal Tar Pitch" coatings are subject to corrosion as the steel reacts to water and rusts. These tanks have a finite lifespan buried in the ground. These tanks can become structurally compromised and pose a health risk. They could collapse and/or leak untreated wastewater directly into groundwater. In the interest of protecting public health and the environment, the Municipality of Anchorage Development Services Department has issued Policy W.05 Standard of Care Regarding the Inspection of Steel Septic Tanks when Performing COSA Inspection. Please request a copy of this policy from the Department if interested. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval.