HomeMy WebLinkAboutTHE TABLELANDS BLK 8 LT 15The Tablelands Block 8 Lot 15 #051-801-55 Municipality of Anchorage Page 1 of 3 Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 wwwr.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SWO50142 PID Number: 051-801-55 Name: S inell Homes Wastewater System: New Address: 1900 W. Northern Lights Anch. AK 99518 ABSORPTION FIELD Phone: Number of Bedrooms: Shallow Bed 344-5678 Five 5 LEGAL DESCRIPTION Soil Rating: 1 Total Depth from original grade: GPDIFI' +1 Ft. Black: Let: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 8 15 The Tablelands +.5 Ft. .5 Ft. Township: Range: Section: Fill added above original grade. Gravel Length: 3-5 Ft. 53 Ft. Well: AWWU Water System Gravel width: 15 Number of lines: 3 Distance between lines: Ft. 5 FL Classification (Private, A, B, C): Total Depth:Cased to: Total absorption area: Pipe Material: Ft. Ft. 795 Ft= ASTM 3034 PVC Driller, Date Drilled: Static Water Level: Installer Data Installed: FL Paisano's Dirtworks 7/14-20/2005 Yield : Pump Set at: Casing eight Above Ground: TANK GPM Fl. Fl. SEPARATION DISTANCES Advantex Treatment System To Septic Absorption Lift Holding ubliclPrivate Manufacturer: Capacity inGallons: From Tank Field Station Tank Sewer Line Anchorage Tank 2,000 well >200' >200' >200' N/A >25' Material: Steel Number of Compartments: Two (2) Surface Water >100' >100' >100' N/A LIFT STATION Let line >5' >10' >5' N/A ize: 500 Gal. an ac rw.. Anchorage Tank/Orenco Foundation >5' >10' >5' NIA 'Pump on' level at: 'Pump off level at: High, alarm at: 28 in. 28 in. 34 in. Curtain Drain None Noted Pump Make B Model Orenco Electrical Inspections performed by: Allied Alaska Electric Remarks: BENCH MARK Location and Description: Finished Floor Assumed Elevation: 100.0 Ft. Engineer's Stamp .�**SS1ttg1kiOF 4 �y Inspections performed by: TLK dates: 1'l 7/14/05 ..... '....;19tn 1 yyl /o�$OII Qyoi Pig e:t0.lfiWr bY 6�J�/06 2"d 7/20/05 Department Health Human it MI% NDER50 � 0` ' of and Services approval PP � revel= s No. CE -4381 1<�,p'••.lt-so-D,�^'F�'� rftonalI t Reviewed an roved b ® w'c /t1Qkela WA Date: �//04 ��p� pROFEss :•�� r4 FE S\ (Rev. IM9) A . rove �! ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) MEMORANDUM DATE: November 4, 2012 TO: Jeff Poet FROM: Mike Anderson, P.E. SUBJECT: The Tablelands, Block 8, Lot 15 Septic System Permit No. SWO50142 Topsoil and seeding has taken place on the septic system area serving the subject lot. Revegetation is complete and there is no danger of erosion to the slopes of the completed mound. The conditional status of the inspection report should be removed. C7 Ax-� 6 � t'•vy�66 Ol S .W ( t d Lr): f •�1�,s.. �{ t 2 _ +i• O d001 8VO NYS too, IL 0 n XTL I ALK.00.00 N oo M.v Lt'til�� \ '1N9 3 30 '1 .St _ eth O) I C iG in f O II% O Z U ' \Y6 � n `m stn " C Z 0 U \ N \\\ to O > LL, O CLQ 0 i 00 \ c W pt N m y H QU" V)U o�ON �O 8 rMQ .O Z O)" C) Z 0 N J nJW _ME�� gig ` a� o Q 6 M $� w 3 J H m Q o T ��r7 J Q CO f0 Q J C`.1 < " �3 ~ [EEE9 1 00 N O o>� Cn L t0 O .LC'8St N..69.0.00 N E 7 2 01 a Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Page 3 of 3 Permit Number. SM50142 TEM - PID No. 051-801-55 R� I 2' EPS Insulntlon —I g ADVANTEX TANK PROFILE AS -BUILT Scale: NONE )J �� !limos November 5, 2005 Anderson Engineering Attn: Mike Anderson P.O. Box 240773 Anchorage, AK 99524 EGEC -M CA L CONTRACT/NG FAX: (907) 677-7766 Subject: Lift Station Inspections at properties stated below. This letter is to confirm that the lift station(s) at: • Lot 2, Block 9 —The Tablelands • Lot 15, Block 8 — The Tablelands were wired by a licensed Journeyman Electrician in accordance with the 2002 National Electric Code requirements. If you would like any further information, please feel free to call our office at the numbers listed below. Thank you. Sincerely, ALLIED ALASKA ELECTRIC, L.L.C. Janette L. Brown, Vice President/CFO cc: file P.O. Bax 876310, Wasilla, Alaska 99687 (907) 373-3893 ofe / (907) 232-8687 cell / (907) 373-3894 fax T•d 468E-ELE (LOS) OIJ10aT3 RMSUTH PaTTTH dTD:20 s0 40 ^aFP MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: May 26, 2005 Expiration Date: May 26, 2006 Permit Number: SWO50142 Parcel ID: 051.801-55 Legal Description: THE TABLELANDS SUBDIVISION BLOCK 8 LOT 15 Design Engineer: 0014 Anderson Engineering Site Address: 22422 SAMBAR LOOP Owner Name: SPINELL HOMES, INC. Lot Size: 40001 SO. FT. Owner Address: 22422 SAMBAR LOOP Total Bedrooms: 5 Permit Bedrooms: 5 PETERS CREEK. AK 99567 - This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By. Issued By. Date: 5�-- yl_o �. is _40= Municipality of Anchorage -� Development Services Department Building Safety Division:' 7 On -Site Water and Wastewater Program s .. 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. bsI—sol_ 55 Permit Number SW Property owner(s) Spineil Homes, Inc. Day phone 344-5678 Mailing address (1)1900 W. Northern Lights Blvd. Suite 200 Anchorage, AK 99517 Mailing address (2))Ag99, Sambar Loop Zip Code Legal description (Lot, Block & Sub'd.) Lot 15, Block 8, 11K jAf3LLLA)Q05 Legal description (Section, Township & Range) Lot Size 40.001 SF Acres/Sq.Ft. Number of Bedrooms Five (5) THIS APPLICATION IS FOR: Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Date of Payment: Receipt Number: it (ill I.`J Receipt Number: (Rev. 12/00) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX May 26, 2005 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 15, Block 8, The Tablelands Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer. The groundwater level on Lot 15, Block 8, The Tablelands Subdivision has unexpectedly risen making our original design for the septic system for this property no longer usable. We are therefore proposing to place an Advantex Septic Treatment System for a five -bedroom home on the property. The attached Site Plan and backup documentation identify the location and configuration of the new septic system and alternate site and the parameters used in the design. Also identified on the plans are the location of the surface drainage, test holes and water service on the lot. The system will not conflict with those on the surrounding lots. Drainage arrows and spot elevations are shown indicating the current drainage patterns. The drainage patterns will be maintained after construction. The test holes placed on this lot revealed silt with some sand. The percolation rate in the upper layers ranged from 40 minutes to 60 minutes per inch. Groundwater was recently noted at 3' below the surface. We are therefore proposing to place a five - bedroom Advantex Treatment System. The terrain of.the lot is such that gravity flow from the filter to the absorption bed is not possible and a second lift station will be required. The absorption bed will be 50' long x 15' wide for a total absorption area of 750 square feet. The bed will be constructed at the existing ground level. Approximately 1' of clean coarse sand will be required to replace the organic layer removed below the bed and to level the bed area. The ground surface on the lot slopes as shown on the site plan from west to east at shallow slopes. The absorption bed will be constructed parallel with the slope as much as possible in conformance with Municipal requirements. All components of the new Lot 15, Block 8, The Tablelands May 26, 2005 Page Two septic system will be constructed a minimum of 100' from any surface water and 10' from the water service on this and adjacent lots. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments dOOI avewvs 0 o ooL'9 & -a ,9Z'Zft ,KtS,fODO N Z1'91-7 \ 'L'153 '3 8 -1.91 (Lw \ s \ \ `8 \M V1� > y� L_ b I c 00 9 I a CLu e (n O cL _ '�. �'� W J JL� bo<cn Fn vi• ` LJ C) s z _ o zci m-- —� �--i w N � O ae w �— € N J W 2 H ,Lf'91;1 N,69,L0.00 N ���•' *' •..; 'f •��I u •1U%•' O,' LOT 15, BLOCK 8, THE TABLELANDS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom Home Raised Bed System Perc. Rate: 40 Min.Anch Advantex Treatment System for 5 Bedroom Home Application Rate: 1 GPD/SF 500 Gallon Lift Station 1' (Min.) Coarse Sand 5 Bedrooms X 150 GPD/1 GPD/SF(Application 750 SF/15 SF (Width) = 50 LF Bed Rate) = 750 SF Absorption Area Length THEREFORE: Construct a 50" Long x 15' Wide Raised Absorption Bed as Shown Below. Remove Existing Piping in Existing Organic Material under Bed and Replace with Coarse Sand. Place Distribution Piping at .5' Above Original Ground Surface. Provide 2" of Insulation and 2' of Cover Over Bed or 3' of Cover. Place Topsoil and Seed on Outer 6" of Mound. 4 2" Insulation & 2' Cover (Min.) 1 •5' O O O S Drainfield Rock 1" PVC 1' Min. Remove Organics and Replace With Clean Sand (See Specification) 2.5' 5' 5' 2.5' NOTE: See Specifications for Clean Coarse Sand. TYPICAL RAISED BED SECTION • (NO SCALE) .�� P�•" C;0 NOTE: Grade Area Surrounding Bed to Drain Away. Minimum 6' Separation From Bedrock. :....;:. 49th Minimum 4' Separation From Groundwater. �n Minimum 200' Separation From Wells in the Area. i""':"""'"""'""""GGA!++ Andemm Minimum 100' Separation From Surface Water or Streams. �0. :Michael E. -4381 ♦ J, No. CE -4381 i Minimum 10' Separation From Water Service Line. �� „•.,_ � „ 0 z H V3 -- -- • 7J Mfg v { g: O 0 { MC Mrrr 8nkO e a a ryr 07 Rd e rr M O NN 6!? N O •M04 Q CL a C H C z- a o rr CD ,110 n CCD f-4 JS >< €� CD o �v. + + sn �- CD cn CD 0 CD r+. • c ADVANTEX AX -20 SEPTIC SYSTEM ANCHORAGE TANK WELDING, INC. m g i y '^ ' � o � `; voo voncuvu+e onrve o STANDARD MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 15, BLOCK 8, TABLELANDS S/D PERFORMED FOR- SPINELL HOMES DATE: 4/11/2005 PROJECT No • M0518 PARCEL ID,#- TECHNICIAN: M. ELDRIDGE DEPTII TEST HOLE # 1 (rat) I 2 READING OB/OG SLOPE TIGHT COMPACTION 3 NET DROP (INCHES) I 4/11/05 4 13 SILTY SANDS W/GRAVELS 1 GM MEDIUM COMPACTION 5 CHARGE SM -GM 0% 6 2 1400 7 16— 0.75" 8 BOH 17 9 11.25' IO WAS GROUND WATER ENCOUNTERED? YFS 4 19 IF YES 9 WHAT DEPIIO ID I I 0.75" DEPTII OF WATER AFTER MONITORING: S' 5 DATE OF MONITORING: SmIlI 5 12 READING G OSS TIMEJ MINUTES) TIGHT COMPACTION DEPTH of OF NET DROP (INCHES) I 4/11/05 SILTY SANDY GRAVELS 13 1 GM 14— 41516 12.0" CHARGE is- 2 1400 30 16— 0.75" BOH 17 1400 11.25' 18 4 19 30 10.5' 0.75" SITE PLAN THI O O TH2 SFE FUTUR= ASBUILT DATE READING G OSS TIMEJ MINUTES) NET TIME (MINUTES) DEPTH of OF NET DROP (INCHES) I 4/11/05 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1330 12.0" CHARGE 2 1400 30 11.25' 0.75" 3 1400 11.25' 4 1430 30 10.5' 0.75" 5 I430 12.0" RECHARGE 6 1500 30 11.25' 0.75" PERCOLATION RATE5(MIN/INCII) FERC. }TOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 5.5 FT. and—L. 5 FT. COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECII ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITI I ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION• LOT 15, BLOCK 8, TABLELANDS S/D PERFORMED FOR: SPINELL HOMES DATE: 4/11/2005 PROJECT No • M0518 PARCEL ID,;y TECHNICIAN: M. ELDRIDGE DEPTII TEST HOLE # 2 (fcct) OB/OG `7 4 SILTY SANDS W/GRAVELS MEDIUM COMPACTION 5 SM -GM 6 7 8 9 SITE PLAN THI O O TH2 SEE FUTURE ASSUILT IO WAS GROUND WATER LNCOUNTEREIr Yrs_ IF YES g MIAT DEPII? iP 11 DEPTH OF WATER AFTER AIONITOROIG: P 0% DATE OF MONITORING: 3/134003 12 13 14 15 16 17 18 19 TIGHT COMPACTION SILTY SANDY GRAVELS GM "®� DATE READING G OSS TIME MINUTES) NET TIME (MINUTES) DEPTH of WATER (INCHES) NET DROP (INCHES) 4/11/05 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1340 12.0" CHARGE 2 1410 30 11.375" 0.625" 3 1410 11.375" 4 1440 30 10.75" 0.625" S 1440 12.0" RECHARGE 6 1510 30 11.375" 0.625" PERCOLATION RATE• 48 (MN/INCH) FERC. }TOLE DIA. 6 (INCHES) TEST RUN BETWEEN. 5.5 FT. and 6.5 FT. COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECII ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 15, BLOCK 8, THE TABLELANDS SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new Five Bedroom Advantex Treatment System, which includes a 2,000 gallon tank with 2 AX -20 Pods to serve the new home on the lot. A second lift station will also be required. System will be placed at the location shown on the Site Plan. The new septic system also includes the construction of a new 50' long X 15' wide X 1' effective depth absorption bed at the location also shown on the Site Plan and at the configuration shown. The distribution line in the bed will be placed 1' above the existing ground surface. The total depth of the bed will be V below the surface. A minimum of 1' of clean coarse sand will be required to replace the organics excavated from the surface of the property under the bed area. The new system must be placed a minimum of 10' from the water service on the lot and those on adjacent lots and 100' from any surface water located near or on the lot. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION The Advantex Treatment System must be installed in conformance with specifications and regulations furnished by the manufacturer, Anchorage Tank and Orenco Systems Incorporated. No variances from the manufacturers specifications will be allowed without permission from the manufacturer and Municipal representatives. Lot 15, Block 8, The Tablelands May 26, 2005 Page 2 of 4 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the bed shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to Lot 15, Block 8, The Tablelands May 26, 2005 Page 3 of 4 placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. SAND GRADATION: 1. Sand used to level the new absorption bed must have the following gradation: 50% Passed the No. 4 Sieve 2% Passed the No. 100 Sieve 1% Passed the No. 200 Sieve 2. The sand source must be approved prior to use. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. Lot 15, Block 8, The Tablelands May 26, 2005 Page 4 of 4 The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX April 23, 2005 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 15, Block 8, The Tablelands Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 15, Block 8, The Tablelands Subdivision intends to construct a new five -bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is currently served by a community water system. No conflicts exist with adjacent septic systems or wells and the proposed septic system on this lot. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The current drainage pattern is identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Test holes recently placed on the lot indicated silty gravel with minor amounts of sand in the area of the absorption trench and alternate site. The accepting soils were tested and found to have a percolation rate of between 40 minutes per inch and 60 minutes per inch. The system is designed with an application rate of .3 GPD/SF. Groundwater was found in the test holes during placement at 10' below the surface and was monitored during the ensuing period at 7.5' below the surface. Our design includes the placement of a new 1,500 -gallon septic tank along with 2 - 84' long and by 15' wide absorption beds to collect and treat the sewage generated in the house. The bottom of the beds will be 2.5' below the surface. The distribution pipe will be 2' below the surface. A flow splitter valve will be installed to insure even flow to each bed. A minimum of 3' of cover will be placed atop the beds and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at varying grades from north to south as shown on the Site Plan with steep slopes near the south end of the lot. The absorption beds will Lot 15, Block 8, The Tablelands Subdivision April 23, 2005 Page Two be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincer�ely, j Michael E. Anderson, P.E. Attachments / 49th ! \ l WICNeEL E. ANDERSON 4 No. CE -419+ . d001 avewvs 0 n o .9Z'Zti A�fS,C0.00 N \ 'L9S3 3 W U ,St ________ _____ ____________—__ \•3 �� Yo \\ a a \M % ZO ; �a z ' Q >'" 00 in L _ 18 • 1 1 oy o m� dr 8N n c �' L r % J e o O I L4 m a z m W� vmy z r-- ---� z C== =-=C t --i LLI CD O — — QJ � rr >r w - E e • .LC*9SI M.GS.MDO N ��•P , -V,6�6.... v 3 LOT 15, BLOCK 8, TABLELANDS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: 5 Bedroom Home Shallow Bed System Perc. Rate: 31-60 Min./Inch 1,500 Gallon Septic Tank Application Rate: .3 GPD/SF 1' Total Depth Drainfield Rock 5 Bedrooms X150 SF/Bedroom/.3 GPD/SF(Application Rate) = 2,500 SF Absorption Area 2,500 SF/15 LF (Width) = 166.67 LF Bed Length THEREFORE: Construct 2 - 84' Long x 15' Wide Shallow Beds as Shown Below. Place Distribution Piping at 2.5' Below Original Ground Surface. Provide 3' of Cover Over Bed and 4' of Cover Over Septic Tank. In Lieu of Fill Provide 2' of Insulation and 2' of Fill. Place Diverter Valve to Insure Even Flow to Each Bed. Existing Ground Geolextile Fabric .5' O O 5' Drainfield Rock Underlying GM 2.5' 5' 5' L BED SECTION NOTE: Grade Area Surrounding Bed to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 200' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. N 2.5' 4' PVC MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 15, BLOCK 8, TABLELANDS S/D PERFORMED FOR- SPINELL HOMES DATE: 4/11/2005 PROJECT No • M0518 PARCEL ID,#• TECHNICIAN: M. ELDRIDGE DEPTH TEST HOLE # 1 (fcct) 09/OG 4 SILTY SANDS W/GRAVELS MEDIUM COMPACTION 5 SM -GM 6 7 s 9 SLOPE lOWAS GROUNDWATER EVCONITERFD? YPS_ IF YES (q NTUT DFJ'TIC Id OEM OF WATER AFTER MONRORDIG: 15' I I DATE OF MONITORING: 4IS1003 12 READING GROSS TIME (MINUTES) TIGHT COMPACTION D ATER F (INCHES) NET DROP (INCHES) 4/11/05 SILTY SANDY GRAVELS 13 1 GM 14- 41516 12.0" CHARGE 15- 2 1400 30 16 0.75' BOH 17 1400 11.25" SITE PLAN THI O O TH2 SEE FUTURE AS9UILT DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) D ATER F (INCHES) NET DROP (INCHES) 4/11/05 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1330 12.0" CHARGE 2 1400 30 11.25' 0.75' 3 1400 11.25" 4 1430 30 10.5" 0.75" 5 1430 12.0" RECHARGE 6 1500 30 11.25" 0.75" PERCOLATION RATELLO--(MINANCII) FERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN:: 5.5 FT. and 6.5 FT. COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECII ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: MUNICIPALITY OF ANCHORAGE • " DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 15, BLOCK 8, TABLELANDS S/D PERFORMED FOR: SPINELL HOMES DATE: 4/11/2005 PROJECT No • M0518 PARCEL ID#• TECHNICIAN: M. ELDRIDGE DEPTH TEST HOLE # 2 (reel) OB/OG 2 3 4 SILTY SANDS W/GRAVELS MEDIUM COMPACTION 5 SM -GM 6 7 8 9 0% SITE PLAN THI O 0 TH2 SFE FUTURE AS9UILT WAS GROUND NATER ENCOUNTERED? yys_ 10 IF YES C% WHAT DEI'nr IV DEMI OF NATER AFTER MONITORING: 7.5- `/S OHIO I I DATE OF MONITORING: 411512M5 I}tC( 12 13 14 15 16 17 18 19 TIGHT COMPACTION SILTY SANDY GRAVELS GM '®� DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DjnEjgTERP (INCHES) NET DROP (INCHES) 4/11/05 TEST HOLE PRESOAKED PRIOR TO TESTING: I 1340 12.0" CHARGE 2 1410 30 11.375" 0.625" 3 1410 11.375• 4 1440 30 10.75" 0.625" 5 1440 12.0" RECHARGE 6 1510 30 11.375" 0.625" PERCOLATION RATE; 48(MI'J/INCII) PERC. }TOLE DIA• 6 (NC}IES) TEST RUN BETWEEN. 5.5 FT. and 6.5 FT. COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECII ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 15, BLOCK 8, THE TABLELANDS SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,500 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of 2 new absorption beds each 84' long X 15' wide also at the location also shown on the Site Plan and at the configuration shown. The distribution line in the beds will be placed at 2' below the existing ground surface. The total depth of the beds will be 2.5'. A flow splitter valve must be placed to insure even flow to each bed. The new tank and absorption beds must be placed a minimum of 10' from the water service on the lot. They must also be placed a minimum of 100' from any surface water. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,500 -gallon septic tank must be procured from an approved source and installed at the location shown if the existing septic tank is found to be defective. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Lot 15, Block 8, The Tablelands April 23, 2005 Page 2 of 3 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: The drainfield shall be constructed to the dimensions shown on the design. The bottom of the bed shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 15, Block 8, The Tablelands April 23, 2005 Page 3 of 3 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. COARSE SAND: 1. Coarse Sand must be graded as follows: 50% Passing No. 4 Sieve 3% Passing No. 100 Sieve 1% Passing No. 200 Sieve INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Municipality of Anchorage Development Services Department +� Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Anderson Engineering Legal description: The Tablelands Subdivision. Block 8 Lot 15 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on — ❑ Calculation error in design. _ ® Additional soils information needed. Proposed and reserve drainfield extend beyond 30 feet test hole radius. ® Water monitoring results inadequate. Shallower groundwater observed than reported on soil ❑ Discrepancy in information submitted. _, ❑ Topographic information missing or Inadequate. ❑ Incomplete; missing _ ❑ Incomplete; missing _ ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils information submitted. ❑ Well log required. ❑ Omission in narrative. ❑ Insufficient fill over tank or field._ ❑ Other. _ Name of reviewer: Julie Makelo. P.E. Date: 5/3/2005 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK rrtr'e. AellI Municipality of Anchorage a -. Development Services Department Building Safety Division on -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.sk.us 343- ge.ak.us �• • � (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL 4/ FOR A SINGLE FAMILY DWELLING Parcell.D. 051-801-55 HAA# 05WLlI Expiration Date: Lellr5lgimiln 1. GENERAL INFORMATION Complete legal description Lot 15 Block 8 The Tablelands Subdivision Location (site address or directions) 22422 Sambar Loop Current Property owner(s) Soineli Homes, Inc. Day phone 344-5678 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address 1900 Northern Northern Llahts Blvd. Anchorane. AK 99517Blvd. Anchorane. AK 99517 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System Five 5 Day phone Day phone TYPE OF WASTEWATER DISPOSAL: ❑ Individual On-site ❑ Individual Holding tank ❑ ❑ Community On-site ❑ ® Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given In paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with -new water sample results less than 30 days old. -(Cer ificates may be reissued for a period of up to one year with"' valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system Is(are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the Information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with ail applicable Municipal and State codes; ordinances, and regulations In effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 12/20/2005 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Conditional approval for ,5_ bedrooms, with the following stipulations: aan inches of top soil on the mound absorption bed and vegetating the mound absorption bed sufficiently,_Fre, r. ii erosion in array a e w th AM(• 1F 65 The work shall be completed.not later than June 15, 2006. Final COSH and final -Lis Work-44--comPlated-_ Additional Comments Attachments: HAA Checklist X Septic System Advisory Well Flow Advisory AND 7e .SEVIvESQ�1���\,. Maintenance Agreements''-!,, : Supplemental Engineer's Report Other By: t ' ` ti ` Original Certificate Date: (Ra. 12M) ..�� Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 188850 Anchorage, AK 99519-850 www.et.anchorage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST A. WELL DATA Weil type _ If A, B, or C provide PWSID #_ Well Log (YIN) Date completed _ Sanitary seal (YIN) _ Wires properly protected (YIN) Total depth ft Cased to ft. Casing height (above ground) In. FROM WELL LOO AT INSPECTION Date of test Static water level R fL Wall production g.p.m. 9 - p.m -WATER SAMPLE RESULTS: Coliform colonles/100 ml. Nitrate mg.A. Other bacteria colonies/100 ml. Date of sample: Collected by - S. SEPTICIHOLDING TANK DATA Tank Type/Materlal _ STEP/Steel Date instaned 7114/2005 Tank size 2,000 gal Number of Compartment g Ckaanouts (YIN) Y Foundation cleanout (Y/N).y Depression over tank (YIN) jy High water alarm (Y/N) Y Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA Date Installed 7/14_2n/ftUrating (g.p.d.eorte/bdnn)I OPD/SF System type AdvaMex/Bed Length 63 it Width 16 fL Gravel below pipe .6 M Total depth 1 fL Eft. absorption area Zjtfe Monitoring tube X Depression over field IN Date of adequacy test Results (Pass/Falq For _ bedrooms Fluid depth in absorption field before test _ in. Water added_ gal. - New depth_ in. Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >s g.p.d. Any rejuvenation treatment (past 12 mo.) (YM 6 type) N If yes, give date D. LIFT STATION Date installed 3/14/2005 Size in gallons 600 Manhole/Access (YIN) Y 'Pump on" level at It In. 'Pump ofr level at al In. High water alarm level at 94 In. Dabrm Bottom of Tank Cycles tested New Construction Meets alarm & circult rmiuirenu ms? Y. E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAift station on lot N/A Absorption fleld on lot N/A Public sewer main N/A Sewer /septic service One N/A On adjacent lots N/A On adjacent lots N/A Public sewer manhoMJdeanout N/A Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >S Property One 317 Absorption field >1' Water main >10' Water service One >10' Surface water >100' Wells on adjacent lots >200' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property One >11Y Building foundation >1V Water main >10' Water Service One' >10' Surface water >100' Ddveway. par *toddle storage >9 Curtain drain None Noted Wells on adjacent lots >21V F. COMMENTS 0. ENGINEER'S CERTIFICATION 1 cer* that I have defemdned through field inspections and 4 49th review of Munldpal records that the above systems are In conformance nrfih MOA HAA guldelloes In effect on this date. awun c ivaumr Engineer's Printed Name Michael E. Anderson. P.E. Na�_'_',,,���,.. Date 12/2012005 44•,ehs HAA Fee S 67 Date of Payment /z,- Zo - VS Receipt Number ' (Rev, 1zVM ,lkta,oS, y� i� ao Waiver Fee Date of Payment Receipt Number HOMES, Inc. January 9, 2006 Re: James & Bianca Cross Lot 15 Block 8 Tablelands 22422 Sambar Loop Chugiak, AK 99654 To Whom It May Concern: In signing below, the above-mentioned buyers release Spincll Homes, Inc. and accept full responsibility to cover the mound or their septic system with six inches of topsoil and seed it in accordance with AMC 15.65. All work must be completed by June 15, 2006. d uyer Buy Spinel homes, Inc. q (o D to _I h/GYo Date 1l910to Date Before me this day of January 2006, appeared James and Bianca Cross and Chemene Brcincr. Qp�.'•OTA •••o��I � N Ry�' g iu'„ pUBLIG r' o OF P'N' 1900 W. NORTHERN LIGHTS BLVD. • SUITE 200 • ANCHORAGE, ALA*Xj9S9 iS44-5678 • FAX: 344-1976 30' b 0 z �n J 41 1 n "=30' ml SOUS♦ 37li •••: *�10 Air ..y AA Ga LS -6091 •.' �R♦ • J �fOssional $-GiN Municipality of Anchorage Development Services Department • '� Building Safety Division : !�`_ On -Site Water and Wastewater Program = �'' 4700 South Bragaw St. s r P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Anderson Engineering Legal description: The Tablelands Subdivision, Block S. Lot 15 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. _ ❑ Additional soils information needed. _ ❑ Water monitoring results inadequate. ❑ Discrepancy in information submitted. ❑ Topographic information missing or Inadequate. ® Incomplete; missing maintenance agreement signed by buyer ® Incomplete; missing manholes on as -built survey, water elevation on profile plan ❑ Additional adequacy test Information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils information submitted. _ ❑ Well log required. ❑ Omission in narrative. ❑ Insufficient rill over tank or field._ ® Other. the upper six inches of the mound absorption bed must consist of top soil and be sufficiently vegetated to prevent erosion. Name of reviewer: Julie Makela. P.E. Date: 12/23/2005 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK