HomeMy WebLinkAboutTHE TABLELANDS BLK 9 LT 2The Tablelands Block Lot 2 #051-741-57 o //'i / Municipality of Anchorage Page 1 of 3 Development Services Department On-Site Water and Wastewater Program - 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW050087 PID Number: 051-741.57 Name: S inell Homes Inc. Wastewater System: New Address: 1900 W. Northern Us. Blvd., Ste. 200 Anch., AK 99515 ABSORPTION FIELD Phone: 344-5678 Number of Bedrooms: Five 5 5' Wide Trench LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: ,8 GPD/Fe 2 Ft Block: Lot: Subdivision- Depth to pipe bottom from original grade: Gravel depth beneath pipe: 9 2 The Tablelands 1 Ft. 1 FL Township: Range: Section: Fill added above original grade: Gravel Length: 2-3 Ft. 165 Ft. Well: AWWU Gravel width: Number of lines: Distance between lines: 5 Ft. 3 >10 FL Classification (Private, A, B, C): Total Deptir: Cased to: Total absorption area: Pipe Material: Ft. Ft. 948 Fe ASTM 3034 PVC Driller: Date Drilled: Static water Level: natation. Date nstallotl: Ft. Pisano's Dirtworks 5126-2712005 Yield: Pump Set as Casing eight Above Ground: TANK GPM F, FL SEPARATION DISTANCES STEP To Septic Absorption Lift Holding ublic7Pnvatea c ren. ubtraody In a ons: From Tank Field Station Tank Sewer Line Anchorage Tank 2,000 Well >200' >200' >200' N/A J >251 Material: Steel Number m Compartments: Two (2) Surface Wator >100' >100' >100' N/A LIFT STATION Lot Line >5' >10' >10' N/A ae: 250 Get. Anchorage Tank/Orenco Foundation >5' >10' >5' N1A Pump ortle__ra: 42 in. 'Pump off level at: 42 High watoralarm at: 44 in. n. Curtain Drain r >20 1 >20 1 >20 Pump Make 8 Motlel Orenco Electrical Inspections pedomned by. Allied Alaska Electric Remarks: _ BENCH MARK ocahon an escnphon: Finished Floor. Assumed Elevation: 100.0 Ft. Engineer's Stamp OF ry4 Inspections performed by: TLK Dates: tat5/26105 49ih `a 0, , fl %op soil Vege}aitbn 2nd 5127105 J i0 MICHAEL •E. ANDERSON s �. t+ha4w approval .0Q.' � �i s 1r,� A GOnG�%IOa o.� (' rOVa� �p No CE-43151 ♦1 Tf �' it 0T.•••�'� Reviewed and approved by: T li c ilo kelp C�l1W� Date: i l�( ��45 ♦♦ �Fo p;..F �s.�P:•�� A rouec�' Gv• o //'i / ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) MEMORANDUM DATE: November 4, 2012 TO: Jeff Poet FROM: Mike Anderson, P.E. SUBJECT: The Tablelands, Block 9, Lot 2 Septic System Permit No. SWO50087 Topsoil and seeding has taken place on the septic system area serving the subject lot. Revegetation is complete and there is no danger of erosion to the slopes of the completed mound. The conditional status of the inspection report should be removed. n Lys \ c o � •rr Od, CL a o: pOre�r•�ZO Ap l NN py. y yo I y I Z I O 1 V 1 > f o0') 0 1 J n m Y m 1 H • V) CU e P4 $C a O o I 6 S N / /� VI n c•1 S 1�/IAS N GU U1 a CD w0 b� of N V / c c o Z p' " R =I Q rN�q N CNN ob bb$„e NI U h In yV 7 H 'EWp W ~o�SI ski L 0% y0 M O Oi 3 < Q I v OMa f' ► Y � �• I W I 80 ssshs� ► s� I s t� G o .���r•p11� < •:••• 4 : ! 1 1 •��1 io 1� r' 0�' d • z •i: Z--------------------------------- �US%��� 'U753 3 8 '1 ,9'li a ,19.19L M.B MOO N Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit No. SW050087 TBM 41=100.00 .E.P. f PID No.: 051-741-57 2' EPS Insulntlon 83.7 N s MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 2, BLOCK 9, THE TABLELANDS S/D PERFORMED FOR- SPINELL HOMES DATE: 5/27/2005 PROJECT No - M0511 PARCEL ID/?• TECHNICIAN: T. L. KIMBROUGH Dlarrn TEST HOLE # 7 (&t) 1 2 READING OB/PT POORLY GRADED SANDS NET TIME (MINUTES) DEPTH OF (INCHES) NET DROP (INCHES) SP 3 1 4 11.5' CHARGE WELL GRADED SANDS W/GRAVELS 5 11:15 GW -SW mmm 10 11 12 13 14 15 16 17 18 19 COMMENTS: SLOPE SITE PLAN O H7 SFF FUTURF ASBUII T WAS GROUNDWATER ENCOUNTERED? NO IF YES @ WIIATDFmv DEFTII OF WATER AFTER MONTFORINO: <2% DATE OF MOMTORING: DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH OF (INCHES) NET DROP (INCHES) 5/27/OE TEST HOLE PRESOAKED PRIOR TO TESTING: 1 11:05 11.5' CHARGE 2 11:15 10 4.63' 6.87' 3 11:16 11,25- RECHARGE 4 11:26 10 4.5' 6.75' 5 11:27 12.0' RECHARGE 6 11:37 10 5.25- 6.75' PERCOLATION RATE I,_5 (MIN/INCI I) FERC. IIOLE DIA. 6 (INCITES) TEST RUN BETWEEN: 1.5 FT. and 2_5 Fr. HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICFIAEL E. ANDERSON CERTIFY THAT T1 HS WAS PERFORMED IN ACCORDANCE WITI I ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON TI IIS DATE: LOT 2, BLOCK 9, THE TABLELANDS SUBDIVISION (ALTERNATE SITE) DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom Home Deep Trench System Perc. Rate: 1-17 Min./Inch 5 Bedroom Advantex Treatment System Application Rate: 4 GPD/SF 1' Drainfield Rock 5 Bedrooms' 150 GPD/Bedroom = 750 SF Absorption Area 750 SF/4 GPD/SF/5 SF/LF'.87 (Red. Factor) = 32.6 LF Trench Length THEREFORE: Construct a 33' Long x 5' Wide x 1' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 1' Below Original Ground Surface. Total Depth to be 2' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over Septic Tank. Topsoil & Seed Upper 6" Natural Backfill 6" 6" 5' 3' Cover or 2" Insulation and 2' Cover Geotextile Fabric 1" Perforated PVC (Holes Down) 3/16" Holes @ 1.5' Spacing Drainfield Rock TYPICAL 5' WIDE TRENCH SECTIO NOTE: Grade Area Over Trench to Drain Away. : tE Minimum 6' Separation From Bedrock. �... Minimum 4' Separation From Groundwater. 0YY Minimum 10' Separation From Water Service Line. � Minimum 100' Separation From Surface Water or Streams: % MONEL E. MDER No. CEu l !!'E'�`2 ELEC ?A CAL CONTRACTING _� EL�G'TRIC� / November 5, 2005 FAX: (907) 677-7766 Anderson Engineering Attn: Mike Anderson P.O. Box 240773 Anchorage, AK 99524 Subject: Lift Station Inspections at properties stated below. This letter is to confirm that the lift station(s) at: • Lot 2, Block 9 — The Tablelands • Lot 15, Block 8 —The Tablelands were wired by a licensed Journeyman Electrician in accordance with the 2002 National Electric Code requirements. If you would like any further information, please feel free to call our office at the numbers listed below. Thank you. Sincerely, ALLIED ALASKA ELECTRIC, L.L.C. 1✓naL_ Janette L. Brown, Vice President/CFO cc: file P.O. Box 876310, Wasilla. Alaska 99687 (907) 373-3893 ofc / (907) 232-8687 cell/ (907) 373-3894 fax I -d 46BC-CLC (LOG) 0?a10a13 eXsetd patties dtO:20 SO 40 AOW Permit Number: SWO50087 MUNICIPALITY OFANCHORAGE 5P r )3a Development Services Department On -Site Water d Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Apr 18, 2005 Expiration Date: Apr 18, 2006 Parcel ID: 051-741-57 Legal Description: THE TABLELANDS SUBDIVISION BLOCK 9 LOT 2 Design Engineer: 0014 Anderson Engineering Owner Name: SPINELL HOMES, INC Owner Address: 22200 OBERG ROAD PETERS CREEK. AK 99567 - Site Address: 22200 OBERG ROAD Lot Size: 85906 SO. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: ❑,/ Disposal Field ❑� Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. THE UPPER SIX INCHES OF THE MOUND SYSTEM MUST CONSIST OF TOP SOIL AND THE MOUND MUST BE VEGETATED SUFFICIENTLY TO PREVENT EROSION. Received By. Date: 'V-16 —0 S-" Issued Byi I 1 /N Date: / �1 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 7 tti�j www.ci.anchorage.ak.us (907) 343-7904 s� ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING ZD Parcel I.D. f)5/ -3N/- S;t- Permit Number SW Property owner(s) Spineli Homes, Inc. Day phone 3445678 Mailing address (1)1900 W. Northern Lights Blvd., Suite 200 Anchorage AK 99515 Mailing address (209U) Obern Road Zip Code Legal description (Lot, Block & Sub'd.) Lot 2. Block 9, The Tablelands Subdivision Legal description (Section, Township & Range) Lot Size 85,906 SF Acre Sq.F THIS APPLICATION IS FOR: Number of Bedrooms Five (5) Sewer Only ® Well Only' ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: 144140 a !—�/5D ` ZS NCaiver Fees: Date of Payment: �{�/ i ^�� Date of Payment: Receipt Number: bbOOLI/L/ iA! Receipt Number: (Rev. 12/00) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) April 18, 2005 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 2, Block 9, The Tablelands Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer. The owner of Lot 2, Block 9, The Tablelands Subdivision intends to construct a new five -bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is currently served by a community water system. No conflicts exist with adjacent septic systems or wells and the proposed septic system on this lot. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The current drainage pattern is identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Test holes recently placed on the lot indicated well graded to poorly graded sand and gravel with minor amounts of silt in the area of the absorption trench and alternate site. The accepting soils were tested and found to have a percolation rate of slightly more than 1 minute per inch to 17 minutes per inch. The system is designed with an application rate of .8 GPD/SF, which is a conservative average of the soils encountered. Some groundwater was found in the test holes during placement and was monitored at 6.5' during the ensuing period. No groundwater was found in Test Hole 6 and it remains dry today. A large portion of the new absorption trench is centered near this test hole. Our design includes the placement of a new 1,500 - gallon septic tank along with 2 - 82' long and by 5' wide by 1' effective depth absorption trenches to collect and treat the sewage generated in the house. The bottom of the trenches will be 2' below the surface. The distribution pipe will be 1' below the surface. A flow splitter valve will be installed to insure even flow to each trench. A minimum of 3' of cover will be placed atop the trenches and a minimum of 4' of cover will be placed atop the new septic tank. Lot 2, Block 9, The Tablelands Subdivision April 18, 2005 Page Two The ground surface on the lot slopes at varying grades from south to north as shown on the Site Plan. The absorption trench will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments U MICHAEL E. ANDERSON i No. CE -4391 I a N 00'07'59 W 261.84' ,p '0 0 0 31.5' T. do E. ESOT. ---------------,w---------------- � • a« `�+.•• 'i � ••.WSJ.• :o 9.I IIy to iii•. '3a � . • o `� 1 I jg h.'IciA •.• { 4 z `'• yp yy4 @ m ` y5L9 m 1 m 1 5; o rn rt I • + I z o r^ u ir 1 1''� I m V C? :nr � N rq cn z a C o CD IF CO 0 I' I; (n 13. to Q l z to C7 I a lyy u 10' Rogo ,J' TGts — 4 fS,tij LOT 2, BLOCK 9 THE TABLELANDS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom House 5' Wide Trench System Perc. Rate: 1-17 Min./Inch 1.500 Gallon Septic Tank Application Rate: .8 GPD/SF (Average) 1' Drainfield Rock 5 Bedrooms X 150 GPD/.8 GPD/SFctApplication Rate) = 937.5 SF Absorption Area 937.5 SF/5 LF (Width)' .87(Red. Fac = 163.13 LF Trench Length THEREFORE: Construct 2 - 82' Long x 5' Wide x 1' Effective Depth Absorption Trenches. Flow Line Elevation in Trenches to be 1' Below Original Ground Surface. Total Depth to be 2' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. NaturalGeotextile Backfill Fahrir. 6' t 4" Perforated t PVC (Holes Down) 1'0" 5' —11 Drainfield Rock TYPICAL 5' WIDE TRENCH SECTIO"' (NO NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 10' Separation From Water Service Line. Minimum 100' Separation From Surface Water or Streams. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION• LOT 2, BLOCK 9, THE TABLELANDS S/D PERFORMED FOR• SPINELL HOMES DATE: 4/1/2005 PROJECT No • M0511 PARCEL ID. - TECHNICIAN: M. ELDRIDGE DEPTH TEST HOLE # 4 (feet) 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 OB/PT POORLY GRADED SANDS SP WELL GRADED SANY GRAVELS GW -SW SILTY -SANDS W/ GRAVELS SM -GM SITE PLAN OH O5 THP �H3 OI TH2 O SEE FUTURE AS9U4T BOH WAS GROUND WATER ENCOU?ffERED' N1 IF YES 9 WHAT DEPTH, NWF DEPTH OF NATER AFTER MONITORING: 7' <2% DATE OF MONITORING: DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DjnEjATER F (INCHES) NET DROP (INCHES) 4/1/05 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1415 10.0" CHARGE 2 1430 15 2.5" 7.5" 3 1430 11.0" RECHARGE 4 1445 15 3.5" 7.5" 5 1445 11.0" RECHARGE 6 1500 15 3.5" 7.5" PERCOLATION RATE; 2(MIN/RVCFD FERC. FIOLE DIA, 6 fINCHES) TEST RUN BETWEEN: 4_5 F('• an4 5_5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORINED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 2, BLOCK 9, THE TABLELANDS S/D PERFORMED FOR: SPINELL HOMES DATE: 4/II/2005 PROJECT No • M0511 PARCEL ID/( TECHNICIAN: M. ELDRIDGE DEPTH TEST HOLE # S (fccO 1 2 3 4 S 6 7 8 9 11 12 13 14 15 16 17 OB/PT SILTY -SANDS W/ GRAVELS SOME COBBLES TO 10" BOH WAS GROUND WATER ENCOUNTERED, Y^S IF YES @,' WHAT DEPTH' 9' DEPTH OF RATER AFTER MONITORING: 6.5' DATE OF MONITORING: 4/15/7995 SITE PLAN TH0 0 5 � O THTH3 O1 TH2 O SEE FUTURE ASBULT iF <2% DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH OF WATER (INCHES) NET DROP (INCHES) 4/1/05 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 1520 12.0" CHARGE 2 1550 30 10.5" 1.5' 3 1550 12,0' RECHARGE 4 1620 30 10.25" 1.75" S 1620 IZ.O" RECHARGE 6 1650 30 10.25" 1.75" PERCOLATION RATE I� 7_I (mrN/C•ICH) PERC. IIOLE DIA 6 INCHES) TEST RUN BETWEEN. 4_5 FT. and 5_5 Fr. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON TINS DATE: 4/18/2005 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: LOT 2, BLOCK 9, THE TABLELANDS S/D PERFORMED FOR- SPINELL HOMES DATE: 4/11/2005 PROJECT No • M0511 PARCEL ID/( TECHNICIAN: T. L. KIMBROUGH DEPTII TEST HOLE #6 (req 2 3 4 5 6 7 8 9 IC 11 12 13 14 15 17 1 �i OB/PT POORLY GRADED SANDS WELL GRADED SANDS W/GRAVELS GW -SW SILTY -SANDS W/ GRAVELS �J SM -GM SITE PLAN TH O O 5 T0 OH4TH3 TI TH2 O SEE FUTURE ASBUILT WAS GROUND MATER ENCOUNTERED? No IF YES (a, WHAT DEPFH+ DEPTH OF WATER AFTER MONITORING: NaHe <2% BOH 7=�n DATE OF MONITORNG: DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) D(INCHES) EPTH of WATER NrFT DROP FINCHES) 4/1/05 TEST HOLE PRESOAKED PRIOR TO TESTING: 11540 12.0" CHARGE 2 1600 20 1.25" 10.75' 3 1600 12,0" RECHARGE 4 1620 20 1.25" 10.75" 5 1620 12.0" RECHARGE 6 1640 20 1.25" 10.75" PERCOLATION RATEI 1.9 (MINANCII) FERC.11OLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4_5 FT, and 5_5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY TIIAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON TIIIS DATE:— ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 2, BLOCK 9, TABLELANDS SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,500 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of two new 82' long X 5' wide X V effective depth absorption trenches at the location also shown on the Site Plan. The distribution line in the trenches will be placed at V below the existing ground surface. Total depth of the trenches will be 2' below the existing ground surface. A Zabel Flow Splitter Valve must be placed to insure even flow to each trench. A separation distance of 200' from any well and 100' between the septic tank and absorption trench and any surface water must also be maintained. A minimum of 3' of fill is required over the absorption trenches and 4' over the septic tank. In lieu of the required fill 2" of insulation and 2' of fill may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,500 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 2, Block 9, Tablelands April 18, 2005 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 1 00'away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock: All pockets of unacceptable materials must be removed and replaced. Lot 2, Block 9, Tablelands April 18, 2005 Page 3 of 3 MATERIAL SPECIFICATIONS: Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. MUNICIPALITY Development Services Department _ ' Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 0 51-741-57 1. GENERAL INFORMATION Expiration Date: 10 — N5 " Z.O 2-3 Complete legal description THE TABLELANDS BLOCK 9 LOT 2 Location (site address) 22200 OBERG ROAD, CHUGIAK, AK 99567 Current property owner(s) MATTHEW & ELIZABETH SWENSON Day phone Mailing address Real estate agent 22200 OBERG ROAD, CHUGIAK, AK 99567 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑ Private Septic Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ® Public Sewer ❑ Waiver request for: Distance: Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 5 5 0 Date of Payment o a 5 Receipt Number 90 5 2 S"y COSA# 05C z 1 1(3 5 Date: Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Address 13030 SUES WAY, ANCHORAGE, AK 99516 Engineer's Printed Name CURTIS HUFFMAN, PE Date 10120/2021 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the _�`1\\\�` system and maintenance. The operational life of all well and septic systems are subject to OF these various and dynamic characteristics and are outside the control of the evaluator of the - �P• . l well and septic system. Therefore, any estimate of how long a system will function satisfactory �• • for current or future occupants or guarantee that no unseen encroachments, deficiencies or �g•''.9 �r discrepancies exist can be given by First Water Consulting& *: TH FWC5 .. • . •:/ 6. DSD SIGNATURE • '. Curtis Huffman CE 128991 System #1 Approved for bedrooms !♦r �Fc��... �� TFC •.10/20129'��� System #2 Approved for bedrooms ill�PROF``i.� Disapproved Conditional approval for bedrooms, with the following stipulatio OF J - �1JlNrSER I\G���`,\ c By: Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other nKT 0 1 Ti-ri-V� m� WATER AND �m WAS_Fr_v'ATER oz^ Jrl!73&G� 411 _1 J - �1JlNrSER I\G���`,\ c By: Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other Pt 4 Legal Description: THE TABLELANDS BLOCK 9, LOT 2 Parcel ID: 051-741-57 If more than 1 septic system on lot: COSA Checklist # _of _ Structure served by this system _ A. WELL DATA – PUBLIC WATER ❑ Well log is filed with Onsite (or attached) Date drilled Total depth _ft Cased to _ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) — in. Date of flow test for COSA Static water level at beginning of test _ft. Comments B. TANK DATA Age of tank(s) 16 years Tank type/material STEP / STEEL Measured operating fluid.level in septic tank ® Standpipes/foundation cleanout per record drawing Date of pumping 10/15/2021 D. ABSORPTION FIELD DATA Which system tested (date installed) 5/27/2005 ® ALL standpipes present per record drawing Total measured depth from grade 3+ ft (max) Measured depth to pipe invert from grade _ft (min) ® N/A – pressurized field ® Monitor tubes go to bottom of effective. If not, state depth into effective ASSUMED ® Code -required soil cover over field W/ INSULATION ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: Well production at time of test _gpm Water storage tank volume_ gallons Well disinfected for coliform test? ❑ Yes ❑ N ❑ Coliform bacteria is Negative Nitrate _mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Date of Sample C. LIFT STATION ® Required maintenance completed Age of lift station 16 years Lift station material STEEL Comments: *FLOAT LEVELS / SEE MAINT. REPORT Adequacy test date 10/15/2021 Results M Pass For 5 bedrooms Fluid depth prior to test 0 in Water added 750 gal New depth 1 in Elapsed time 15 min Final fluid depth 0 in Absorption rate 750 gpd Any rejuvenation treatment (past 12 months) N If yes, enter date E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' IN Yes if No ft Wells on Adjacent Lots: Community Sewer Manhole/Cleanout > 100' ❑ Yes if No ft ❑ Yes if No Neighboring Tank > 100' ❑ Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No Absorption Field on Lot > 100' ❑ Yes if No ft Holding Tank > 100' ❑ Yes if No Neighboring Absorption Fields > 100' Surface Water > 100' ® Yes Animal Containment > 50' ❑ Yes if No ❑ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' E] Yes if No ft ❑ Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No *5+ ft Surface Water > 100' ft ft ft ft ft ® Yes if No ft Property Line > 5 IN Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ® Yes if No ft Private Wells > 100' ® Yes if No Water Main > 10' ® Yes if No ft Community Wells > 200' ® Yes if No _ Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ® Yes if No ft If absorption field is under driveway comment below Property Line > 10' ® Yes if No _ ft Wells on Adjacent Lots: Water Main >10' ® Yes if No ft Private Wells > 100' ® Yes if No ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS *PER CODE AT TIME OF INSTALLATION. G. ENGINEER'S CERTIFICATION I certify that / have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. •. 7H jj • • Curtis Huffman : f¢ �'c'c •. CE 128991 ��,�j`�pROFESS AW M, ft MUNICIPALITY Development Services Department �° Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Lift Station/Pump Vault Owner Street Addressoa a 0 D obe t -r-- Ra Septic Tank: -Sludge level inches -Pumping: required (g no -Pumping completed es no Lift station: -Pump basket cleaned Nes I no -Effluent filter cleanedes no ` -Control floats cleanede no -Proper float settings confirmed es no -Operation satisfactory e no Alarm System: -Dedicated electrical alarm circuit yes no -Audible and visual alarm inside dwelling e no Alarm system operation sat isfactoni not satisfactory Manhole Riser -Ground water intrusion at riser to tank connection es no -Ground water intrusion around pipe penetrationses no •\,�3eep hole functional es no -Manhole lid: Functional 0 no Insulated yes no Properly Securedes no Other -All manufacturer required inspections and maintenance completed & no Comments: Qualified Maintenance Provider: Technician�� Company Signature 10-4, 1 Date of maintenance I I ...Oza I �!. Municipality of Anchorage • -r On-Site Water and Wastewater Program oma" .„. ,� 1_ (907) 343-7904 LJ Intl 1 i o S A r r l Y CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 051-741-57 Expiration Date: , F- 1 5- -4, 1. GENERAL INFORMATION Complete legal description The Tablelands Block 9 Lot 2 Location (site address) 22200 Oberg Road,Chugiak, AK Current Property owner(s) Anliker Day phone 529-0193 Mailing address same Real Estate Agent Joe Lowndes, KW Day phone 317-4830 4.2. TYPE OF DWELLING: �,\'' 1, ® Single Family (w/wo ADU) ❑ Duplex a rr•.;., , L.,:J , ❑ Multiple Dwellings (Single Family and/or Duplex)= \,,,______ . 3. NUMBER OF BEDROOMS: 5 r`- 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual Individual Water Storage ❑ Holding Tank ❑ Community Class C Well ❑ Community ❑ Public Water System ® Public Sewer ❑ Received by: `// Date: //A -7// 7 COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 4, Date: Date of Payment MAIM'' Date of Payment Receipt Number 0485ZA Receipt Number COSA# M04/5-3.0 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm NorthRim Engineering Phone 694-7028 Address PO Box 770724, Eagle River Engineer's Printed Name Steve Eng Date 11/14/2017 6. DSD IGNATURE • System #1 Approved for 3 bedrooms. System #2 Approved for bedrooms. Disapproved. 04/7 Conditional approval for bedrooms, with the following stipula o' ON-SITE �;'. WATER ANO WASTEWA ER c AM - O,o ANT SER • Sw& Original Certificate Date: 1 ( r( �( The Municipality of Anchorage Devlopment Services Division(DSD)Issues Certificates of On-Site Systems Approval(COSA)based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 9-1-12.doc If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Sate Systems Approval Checklist Legal Description: %/V' % 8L 6 L,4iAl?_S 57 4.2 Parcel ID: O 5 f 7 yf 5- 7 A. WELL DATA i c Well type If A, B, or C provide PWSID# Well Log (YIN) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic ig/L Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material S /�/ S T � Date installed 5/06/(25 Tank size 2i OGOgal. Number of Compartments 2 Cleanouts (Y/N) Foundation cleanout (Y/N) Depression over tank (Y/N) High water alarm (YIN) y Date of pumping • S Pumper 3A Ai i T il"C y Pd./p1/7r(2 S C. ABSORPTION FIELD DATA Date installed 5/2 7/o5Soil rating (�p.d,lft2 or ft2/bdrm) O- 8 System type S 1 / r�tich Length /C 5 ft. Width ft. Gravel below pipe / ft. Total depth q_C ft. Eff. absorption area !q ye ft2 Monitoring tube y Depression over field Date of adequacy test ///?I/ 7 Results (Pass/Fail) P For 5 bedrooms Fluid depth in absorption field before test Q in. Water added—75 O gal. New depth . _ in. Elapsed Time: 30 min. Final fluid depth 0 in. Absorption rate >_ 7 SO g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N & type) /Av If yes, give date D. LIFT STATION Date installed 572416 S Size in gallons 2 So Manhole/Access (Y/N) "Pump on" level at zip in. "Pump off' level at 3 8 in. High water alarm level at L./ 7 in. Datum dor-To ", Cycles tested Meets alarm&circuit requirements? V E. SEPARATION DISTANCES WELL ON LOT TO: PvBL(C- Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer/septic service line Holding tank Animal containment areas Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5 'f" Property line lG '+ Absorption field /6 (1f- Water *Water main "f- Water service line /CI (-f Surface water /6O " Wells on adjacent lots 2C I+- ABSORPTION FIELD ON LOT TO: Property line /O r� Building foundation l0 'f Water main /0 A!) ` /QC) f 1- id Water Service line � Surface water /QDriveway, parking/vehicle storage /i". Curtain drain LlAJ/ Wells on adjacent lots ZOO -f' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that l have determined through field inspections and "•' 5; -4 review of Municipal records that the above systems are in - � conformance with MOA COSA guidelines in effect on this date. = ,• Engineer's Printed Name S E CS r r Date /(// f//7 • COSA yellow sheet 2-6-15.doc L t jit(l4 Municipality of Anchorage • Development Services Department �• Building Safety Division On -Site Water and Wastewater Program ` 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcell.D.WI-741.57 HAA# fir) t)5RR Expiration Date: i�a0un 1. GENERAL INFORMATION Complete legal description Lot 2, Block 9. The Tablelands Subdivision Location (site address or directions) 22200 Obem Road Current Property owner(s) _Spinell Homes. Inc. Day phone 3445676 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address 1900 Northern Lights Blvd, Anchorage AK 99517 Day phone Day phone Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System Five 5 The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given In paragraph 5 by an Independent professional civil engineer registered In the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. TYPE OF WASTEWATER DISPOSAL: ❑ Individual On-site ❑ Individual Holding tank ❑ ❑ Community On-site ❑ ® Public Sewer ❑ . The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given In paragraph 5 by an Independent professional civil engineer registered In the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined In the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system Is(are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the Information obtained from the Municipality of Anchorage files and from my Investigation and Inspection, the on-site water supply and/or wastewater disposal system Is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522.7773 Address P.O. Box 240773 Anchorage AK 99524 Engineer's Printed Name Michael E. Anderson P.E. Date 11/8/2005 S. DSD SIGNATURE Approved for _ Disapproved. _ bedrooms. a Conditional approval for 4- bedrooms, with the following stipulations: r Anliker, shall be responsible for placing six inches of top soil on the mound absorption field and vegetating the moon su cent y to prevent erosion by June 15, 2006. lju �QNLITYop! r � Additional Comments ATFR o :• PRCG ATFR •; m, J Attachments: HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other By Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division Onsite Water & Wastewater Program 4700 South Bragaw St. P.O. Box 190850 Anchorage, AK 99519-6850 www.d.arohorage.ek.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 2. Block 9. The Tablelands Subdivision Parcel ID: 051.74W A. WELL DATA ! Well type _ If A B, or C provide PWSID 8Well Log (YIN) Date completed _ Sanitary seal (YIN) _ Wires properly pfd (YIN) Total depth fl Cased to ft. i Casing height (above ground) in. ! FROM WELL LOG AT INSPECTION Date of test Static water level It Ij It, Well production g.p•m. 1 g,p•m, WATER SAMPLE RESULTS: Coliform colonies/100 ml. Nitrate mg.A. Other bacteria colonkWI00 ml. Date of sample: Collected by: B. SEP ICIHOLDING TANK DATA Tank TypelMaterial—STEPMeel Date installed 6/268005 Tank size 2.000 gal. Number of Compartments Cleanouls (Y/N) Y Foundation cleanout (YIN) Y Depression over tank (YIN) High water alar (YIN) Y t Date of pumping Pumper New Construction C li C. ABSORPTION FIELD DATA 1 Date installed 01@005 Soo rating (g.p•d./fe or fe/bdr) A OPD15F System type -F Wide Trench Length 165 ft. Width 5 R Gravel below pipe 1 ft. Total depth &I It. EB. absorption area $}iZtt° Monitoring tuba X Depression over field H t Date of adeauacy,test Results (Pass/Fall) For _ bedrooms Fluid depth In absorption field before test _ In. Water added_ gal. New depth_ in. Elapsed Time: _ min. Final fluid depth _ In. Absorption rate >- g.p.d. ! Any rejuvenation treatment (past 12 mo.) (YIN & type) N If yes, give date it 6 D. LIFT STATION Date installed _;00s 'Pump on' level at 42 in. Datum BOOM of Tank E. SEPARATION DISTANCES Sae in gallons 250 Manhole/Access (YM) Y 'Pump off" Tavel at 42 in. High water alarm level at M. in. Cycles tested New Conatrueann Meats alarm 3 ciraril requirements?,y SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAiR station on lot 1UA Absorption field on lot NIA Public sewer main -NIA Sewer /septic service fine -K%. On adjacent lots _NIA On adjacent lots _NIA Public sewer manhole/cleanout _NA Holding tank _ N►A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property fine Absorption field>5 Water main >10, Water service line >f0' Surface water >IW Wells on adjacent lots >= SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10 Buffding foundatlon _?J Water main >10' Water Service One >10 Surface water >100' Driveway, parkingAmhide storage >S _ Curtain drain _ None Noted Wells on adjacent jots >jW F. COMMENTS G. ENGINEER'S CERTIFICATION OF �saV I cert Y that I have determined through field in un' inspections are and review of M rdpal records that the above systems re in 49th conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name_Michael E Anderson P Sj :aOUX L MOM Data Jiffs 05 4 � �4rw�.::A11'♦ HAA Fee Z 5'1 P— Date of Payment //- h'os Receipt Number -76- 4-q 2 - (Rev. lwv. i2iool Date of Payment Li/I X2 Receipt Number g�c D m z o 0 JmN wzto �mr I mm(1)oz o \ � Z r r 0 Cilv � 0 N to z r LY, in N U)mz mxcc�o�mv— o Z �mrnEmmtn�-um m S NZA z� �nOAm z xmoo�mm:c o zm z� �r o m mN;��mvFil� m n c0C: ;DQz -P tin o �yo-noM�mC� Eq z �ozmmoo o==1 z Oz 2 En -n -N.i N u) -n 'm0 Z ` N Lo Zmacmyy=D�Zvm O n 0000 r'n -iN -Di m0��=�o_� m z 1� Fzo rr�* mo-<zomm—zm vvzm�vv p>S��ov = N m u nrrm'So'w iai aa, � \ ¢ f 'yr FS'yl ko co IRN N O fTl D r 0 CD i r-- m � N'Av t0 N 0 0 0 0 A rCl)(A C QD 0 Z ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX MEMORANDUM DATE: November 18, 2005 TO: Julie Makela, P.E. FROM: Mike Anderson, P.E. SUBJECT: Lot 2, Block 9, The Tablelands Subdivision Septic System As -Built Certificate of Health Authority Approval We have modified the location and type of alternate system site for the subject lot to include an Advantex Treatment System with a 33' long absorption trench. The location of the trench is shown on the revised Plan As -Built. We have also verified the electrical inspections were completed by Allied Alaska Electric and their company name is shown on the inspection report. A notarized statement is included from the buyer of the house on the property relieving Spinell Homes of the requirement to place topsoil and seed on the absorption trenches. The owner will complete the work in the spring. The fee has been paid for a conditional Certificate of Health Authority Approval. Please let me know if you have further questions. 'f3(.e7 'fi.l IS.w r1 HOMES, Inc. November 14, 2005 Re: Blaine & Tina Anliker Lot 2 Block 9 The Tablelands Subdivision To Whom It May Concern: r'1 In signing below, the above-mentioned buyers release Spinell Homes, Inc. and accept full responsibility to topsoil & hydro seed the areas required by the Municipality of Anchorage for their septic system. �s //_ Buyer Date Spinell Homes, Inc. I (/15105 Date •.15'of do w 0 ti :N ' '.'PA �it�i �14,4oii�J: Auyu**,L%.� W �S a�put�P�A 1900 W. NORTHERN LIGHTS BLVD. • SUITE 200 0 ANCHORAGE, ALASKA 99517.344-5678 • FAX: 344-1976 ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 FAX MEMORANDUM DATE: November 8, 2005 TO: Julie Makela, P.E. FROM: Mike Anderson, P.E. SUBJECT: Lot 2, Block 9, The Tablelands Subdivision Septic System As -Built Certificate of Health Authority Approval The design and permit for the septic system on the subject lot requires the placement of topsoil and vegetation to prevent erosion. This work can not be accomplished at this time due to the inclement weather. The new owner of the property has provided a statement to the effect he will complete the vegetation of the mound in the spring. A copy of that letter will be forwarded to you when it becomes available. Please let me know if you have further questions. Municipality of Anchorage Development Services Department ue* Building Safety Division : • - - t' `� On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 s A ` TV www.muni.orglonsite (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Anderson Engineering Legal description: The Tablelands, Block 9. Lot 2 The attached paperwork has been reviewed and Is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. _ ❑ Additional soils information needed. ❑ Water monitoring results inadequate. ❑ Discrepancy in information submitted. _ ❑ Topographic information missing or inadequate. _ ❑ Incomplete; missing ❑ Incomplete; missing _ ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. _ ❑ Proposed system too deep for soils information submitted. _ ❑ Well log required. ❑ Omission in narrative. ❑ Insufficient fill over tank or field._ ® Other. 1.) Need to pay conditional fee; 2.) Please provide notarized o 50 feet from a slope of greater than 25% Name of reviewer: Julie Makela, P.E. Date: 11/16/2005 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK