ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number. SW030128
PID Number. 011.122-61
N.ma:
James and Patti DonleyWastewater
System: New
Aaa.w
8323 Sky Mountain Circle Anchorage,
AK 99502
ABSORPTION FIELD
F'"""
w of sea as n:
Deep Trench
243.3078
Four 4
LEGAL DESCRIPTION
smr R.i.q:
1.2
Total Dep, ham wvnei praWs:
GPOTe
11 FL
6b Lal: SbdrAs«c
D.phbpWm h«n&Vp araW:
13nv WPM hpP.:
3 29
Sky Hills Phase 3
3 FL
8 FL
To.nev: ROW:
Cr LOVIN
3.4 Ft.
32 Ft.
Well: Municipal Water System
GrwN wNh:
5.8
Nu all
1
Dmrrw Wlwsen "s.
fl.
FL
Cb W"M (Prune, A 9, Cr
T" Dept[
Cewa W.
oW .owrpan «w
W. tww
512 FIS
ASTM 3034 PVC
D�
au Dnnsa
su K w«« Levu:
��1i7W
ICA) 7/22.23/2003
FL
99C
Tnq:
Pure set k
Cae•w 400AAbove cresta
TANK
GPM
fl.
Ft
SEPARATION DISTANCES
O septic 17 Holding O S.T.E.P. 0 Other.
To
From
Septic
Tank
Absorption
Field
Lift
Station
Holding
Tank
ubtwprtvate
sew
Anchorage Tank
Y
1250
Well
>200'
>200'
NIA
NIA
>25'
Steel
Two (2)
sM+ wae,
>100'
>100'
WA
WA
LIFT STATION — NONE ON LOT
t.au»
>5'
>10'
NIA
WA
cN
FOL.dri
>5'
>10'
NIA
NIA
h
hP""a''"'"'
WO .« m
h
None
Noted
Ekarr+i Yupeanra p.lormW ay
CM nl}Y1
R~U:
BENCH MARK
Front Porch Slab
100.0 FL
Engineer's Stamp
Inspections performed by: MEA
Dates: 10 712212003
°z 49th ^�;
�
2ne 712312003
.
'� �1 MICNAEL E. ANDERSON
Department of Health and Human Services approval
P PP
. �j No. CE -4381
f
.j 1f, %.•y
RN 1imwed and approved by
Date:
'Mrr r'G •
♦44ePF0
(R
`•, ���:
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number. SW030128
^C
sh
C
5%8" REE^AR (TYP C%R PLAT)
4C. D
Ar
16.1
52
II 9
20.4
C3
V` A
f
Mt
O n>
Alter e
C4
Site
55.4
G_tr.
/
I11
TH B
I
a
I
0
0
5%8" REE^AR (TYP C%R PLAT)
4C. D
J 6neerv'
�O.
r
F
O.
\1S
Bedroom
LOWEST
FF - 199'
S1
S2
M1
<31
A I B
St
R
16.1
52
26.8
20.4
C3
30.5
f
Mt
I
\
Alter e
C4
Site
55.4
1;
TH B
I
J 6neerv'
�O.
r
F
O.
\1S
Bedroom
LOWEST
FF - 199'
S1
S2
M1
<31
A I B
St
20.2
16.1
52
26.8
20.4
C3
30.5
23.5
Mt
43.2
45.2
C4
62.5
55.4
N S700'00" 159.58'
PLAN AS -BUILT
SCALE 1' = 40'
LOT 29, BLOCK 3, SKYHILLS SUBD., PHASE 3
Page 2 of 3
PID No. 011-122-61
Municipality of Anchorage Page 3 of 3
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number. SW030128
PID No. 011-122.61
ru
Cq S Y
PROFILE AS -BUILT -
Scale: r - 10'
ro
W
Q
n
U
-U
O
M f/j
M6
i W
LIJ�
0)
0)
O
N
\ L=
O P°
M
� Nook
Wzc3wWozrow
r>az .6 Ui"CZD a Li
5 (/) - F- U O
(n Q Q= ZZ S O O u Z U
LLJZ S L, � N
=aW L�OZQNZ V) FS -
Of
_>ixOU2ow00
o v }. Z N
J of
Q m F- J W Y U Q w Q p V I
S N CO F- t- U H O p
m ~ W W N X W W' m W Z W
zwof=)O:::) Z
CLF-- w�=mNm o
wWWwFO~U=GH w U
= U O� M N Z W Z Q O
D )-�U W ZO om m Q_ Z
F- W Z_
W W O~ Z Q� O O J OU F
Q m Z O
W oU V) P>d ��Fa- Q Z
S
of Z w a Z W N
J _dr(U cu 7S W
L� ? > d' p N
d Q Q V \ r)
f '- 'U) 0 S V) p z i
�F�go Q� o
o�
z N m¢ v o
�y� N
W L7 V) W W
N
�O N O
Q L� (O O S O
N w^ U
Q a o c
Q
Municipality of Anchorage
Development Services Department
ue*
Building Safety Division *A1
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET
To: Anderson Engineering
Legal description: Sky Hills #3. Block 3__Lot 29
The attached paperwork has been reviewed and is being returned for the following reasons:
❑ Original signature or stamp missing on
❑ Calculation error in design. _
❑ Additional soils information needed. _
❑ Water monitoring results Inadequate.
❑ Discrepancy in Information submitted. _
❑ Topographic Information missing or inadequate.
❑ Incomplete; missing
❑ Incomplete; missing _
❑ Additional adequacy test information needed.
❑ Water sample unacceptable. _
❑ Measured/proposed distances/dimensions missing.
❑ Locations of all soils, percolation and water monitoring tests not shown. _
❑ Proposed system too deep for soils information submitted.
❑ Well log required.
❑ Omission In narrative. _
❑ Insufficient fill over tank or field._
® Other. On-site wastewater disposal system must be installed by an approved installer.
Name of reviewer. Julie Makela. P.E.
Date: 2/4/2005
Please supply the necessary information and re -submit your request.
LEAVE THIS FORM ATTACHED TO THE PAPERWORK
Ga c oc\6Fse s1 <-\ •�c� c r• o c c.ccd�c� kb
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water d Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: May 14, 2003
Expiration Date: May 13, 2004
Permit Number: SW030128 Parcel ID: 011-122-61
Legal Description: 43KY HILLS PHASE 3 SUBDMSION BLOCK 3 LOT 29
Design Engineer. 0014 Anderson Engineering Site Address: 8323 SKY MOUNTAIN CIRCLE
Owner Name: JAMES A. & PATTI E. DONLEY Lot Size: 40119 SQ. FT.
Owner Address: 8323 SKY MOUNTAIN CIRCLE Total Bedrooms: 4 Permit Bedrooms: 4
ANCHORAGE. AK 99502 -
This permit is for the construction of:
❑✓ Disposal Field ❑? Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be In accordance with:
1. The attached approved design..
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either. A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
7/2. 2/03 Fiver. Cps-L.E0 i¢N0 6AA1rJ iO MOvE TKC FIEZ-D
FROM rHF L.,rxsr S/DF 0Jc H&N SE TO rttE 5"r�T 5r01!, SOjA.f HA✓E
PEEN DONE 4N40 X} ivEw OF S 163AV GLM BE S aOn. i n.Cd 7-141.7
R.r rp RN Uay. 9
Received By:
Issued By:
Date: (�
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 011.122.61 Permit Number SW 030/28
Property owner(s) Jim and Patti Donley Day phone 243.3078
Mailing address (1) 6614 Chevignv Street Anchorage, AK 99502
SITE
FAaiBagaddress (2) 5323 SkY NottvrAim CIRCLE Zip Code 995-02
Legal description (Lot, Block & Sub'd.) Lot 29, Block 3, Sky Hills Subdivision, Phase 3
Legal description (Section, Township & Range)
Lot Size 40.119 SF Acres/Sq.Ft.
THIS APPLICATION IS FOR:
Number of Bedrooms Four (4)
Sewer Only ® Well Only ❑
Sewer and Well ❑ Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees: Waiver Fees:
Date of Payment: 5A /n -T Date of Payment:
Receipt Number: Receipt Number.
(Rev. 12/00)
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
•7773 522-6779 (F
MEMORANDUM
DATE: July 23, 2003
TO: Dan Roth
FROM: Mike Anderson, P.E.
SUBJECT: Lot 29, Block 3, Sky Hills Subdivision, Phase III
Revised Septic System Design and Site Plan
We have revised the design for the septic system for the subject lot as discussed with
you earlier. The existing test hole completed during subdivision development is within
30' of the new trench. Soils encountered were fine sands with silt identical to those
found in other test holes on the lot. The percolation rate was verified at less than 5
minutes per inch.
The trench sidewall sloughed during construction and the trench varies from 5' to 8'
wide with an effective depth of 8' and a length of 32'. Should absorb water until the
next ice age.
Please let me know if you have further questions.
99-140 PERMIT NO. SW030128
SKYHILLS 'SUBD.1 PHASE 3
LOT 29, BLOCK 3
40,119 S.F.
206' ELEVATIONS BASED ON -1972 NGS DATUM 1TYP)
w/ 5/8' REBAR (TYP PER PLAT)
630•
Ac �RNf S �t'755je
02 30 , a3, 05.
t
/ Site o e 50' n x 5' ide 150'
T I x.4' Effective Depth
Abso
ti Tren
U, N l Zoe• x
-0., \13' -
/ Fb411NC h PROPOO
\ Four Bedroom PATrEt2N
I n i I TM B Home
o N I 1.250 Gc1Io
' o' I Septic Tank
oter
f (ane en'1Ce
/
206' ~�
T
s �
F
R' r
O)�
F
TP 28
3B
Lowm
FF - 199'
1,250 Ga%lon
Septic Tank
32' Long x 5' Wide
X 8' Effective Depth
Absorption Trench
N 90'00'O0'E 159.58'
210'
SITE PLAN
SCALE 1' = 40'
9th
N1 E ONOEXS@1:
Municipality of Anchorage
Department of Health & Human Services
825 L Street, Anchorage, AK 99502-0650
SOILS LOG - PERCOLATION TEST
Performed For: Bob Klein Date Performed: 9/28/99
Legal Description: tot 28 Block Z Sky Hille Phase III
11 I OG/PT
7
1
Sand, Silt
Some Gravel
SP
Was Groundwater
Encountered? No
If Yet, What Depth?
Depth to Water
After Monitoring None
Date: 10/10/99
SP
Fine Sand
Some S:%!
406
OF
11
r 1
491H •*�o
I r
.w - OCNAEL L ANDERSON o
�1l6n : CE -4381
I
Reading
Date' Gross
Time
Net
Time
Depth To Net
Water Drop
1
28 -Sep 15:22
.5"
2
15:32
10
2.5" 2"
3
15:33
..5"
4
15:43
10
2.5" 2"
5
15:44
.25"
6
15:54
10
2.25" 2"
it®�%;��� �: Perc. Rate: 5 MinJlnch Perc. Hole Diameter: 6"
Bottom of Test Run Between 6 Ft. and 7 Ft.
Hole
Comments: Percolation Cavity Presoaked Prior to Testing.
Performed By: Fd Sanderson. nderson. I, Mi hs 1 F Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 10/25/99
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 522-6779 FAX
May 7, 2003
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 29, Block 3, Sky Hills Subdivision No. 3
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 29, Block 3, Sky Hills Subdivision No. 3 intends to construct a new
four-bedroom home on the lot. The subdivision is currently served by the Municipal
water system. We are therefore requesting a permit be issued for the construction of a
new septic system to serve the home. The attached Site Plan and backup
documentation identify the location of and configuration of the new septic system and
alternate site and the parameters used in the design. Also identified on the plans are
the test hole locations and the septic systems on the surrounding lots. Drainage arrows
and spot elevations are shown indicating the current drainage patterns. The drainage
patterns will be maintained after construction.
The test holes placed near the location of the proposed absorption trench and alternate
site indicated clean sand with some gravel and varying amounts of silt and percolation
rates approximating 2 to 5 minutes per inch. No ground water was found during
placement of the test holes and none was noted during the monitoring period. We are
therefore proposing to place a 1,250 -gallon septic tank and a 50' long x 5' wide x 4'
effective depth absorption trench. The distribution pipe will be placed 5' below the
existing surface and the total depth will be 9'. Sufficient fill will be placed over the septic
tank and absorption trench to prevent freezing.
The ground surface on the lot slopes as shown on the site plan from north to south at
varying slopes. The back of the lot slopes steeply to settlement ponds near the old
Sand Lake pit. The absorption trench will be constructed at the front of the lot parallel
with the slope as much as possible in conformance with Municipal requirements. All
Lot 29, Block 3, Sky Hills No. 3
May 7, 2003
Page Two
components of the new septic system will be constructed a minimum of 100' from any
surface water and 10' from the water service line on the lot.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future. The subdivision is currently
served by the Municipal water system.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
�Y EA. -J,
Michael E. Anderson, P.E.
Attachments
0
WCIi LEI E. ANJERSO4
No CE -4381 j
• ; (,`
TP
10-7-A 10-3-e
LGg1 C3j �'�� 10
W
1 ' G` /qri i _ \\\ 40.182 sq.ftV i Ela_ 1 '
`--
I
33
00�t�N ��-3- 22-3-A22 11
I
1 a 40,525 sq.ft. \ N 45,103 sq.ft.cc
�y w>P n n G ip
to
27-3-e \\\lA� �� U Ty
1 \ Sid a3 -3-A 1 In
0 1 0
OS C� 10' ORAOIACE ANO ,^,.ASL 1 0 `
43,6.3Z51sq.ft. 5q2 S9'>> rv� \C.T1�11yo EASEMENT I p 1
' .41 2 41.166611sq.ft. rte \ C` CS �` ` ` S7;;Tg31.
` ` m
�tir� �w / J`- W J208. 4 w
T
O 10' STOVE a: TP `.I I 1
i by ^� 73-3-C 73_3-9 23-3-A - G / TRNL EASEMENT( I ' 1
�y1 fill O'
1 STOVE =0' ORAINA�EASEMENT G^^' / `20' TRAIL 32 ;0 �' 1 _v
1 MAINTENANCE 1� �SBf $8'47' EASEMENT J Tr o�
I EASEMENT ro - E. - 40,418 sq.ft.I O
---05.47'- _ a7-3-Aj11n
ro
10' SLOPE:'/-
IK 1,1 2EASEMEN70 CE
EASEMENT
TM TIP 24 G •s,• e I.� 1
7. 3-90 70A 41,347 sq.ft. 0
1
S7
,a' 1 �� 6'07'52•E 1° 31.
29' ' ��T!' _ G�0 J0. �e al -3-A 40.350 3q.1t. .� 1
J0:
Q1 1 A—� , d •M N ` F
I ' ' 1
i i / / 8► E •EJ 3
WI
i\ 225.11' �� / : • ti^ .���a�
1.• h pT •'• wr 30 PO Q�oi 4''y 1
� C
is 26 �1~ t• h-/{T/}1s ••• i /'^d THIS PROJECT
;Q m 41,436 sq.tt.
N co C1 I 1
a
26-3-a VACANT � �: lye ^- � cu
;0 1
`" ` c
i TRACT A
I / ; y 3-r: M
m V ;n 107,780 sq.ft.
. Mass%%11 1
126-3-A •� C7? G�� SA •, I I ��'A 9144 1
i 5y1 9q?1 oAl� f.
3"E 49th
amity, {I : • ••,>���j 1
� + 49th � 1
m 27 N . 1P 159.�i8' : Jd. ��..jJ; •• 1
1 xi�41.892 sq.ft. r, •. os• ilr;7•� x•S �%... 4.I 1
A o o 27-3-• VACANT :` c^. % :•MICHAEL E ANDERSON. C: 1
!3 28 •. f't No. CE -4381
11TIP�• r^ 44,797 sq.ft. 6> ?O •41•'•..,,. ++�•`�•,`Ir.� i
1 !�C O 441 1V"'i�� ;
q�.,..,.
00 27-3-9
11 V! CEA EASEMENT (SEE NOTE 10) ---- 10' UTILITY EASEMENT -_- ���` _4_4_°1A- -- - J.
30�
1------ - - -- -- �------174.12'---_
------- ---'--328.77-------
99-140
SKYHILLS SUBD., PHASE 3
LOT 29, BLOCK 3
40,119 S.F.
206' ELEVATIONS BASED ON 1972 NGS DATUM (TYP)
ftZ— 5/8' REBAR (TYP PER PLAT)
/
C. OR4f S >�755�,
50 Long x 5' P' de 150'
x 4' ;Effective Depth
T Absorption Trency,
Zoe• x I I
/ I ,Four Bed
TH B Home
It 1
o,°„ i 1®250 Gallon
o I Septic Tonk
C!
/
o er v
er
! Line Ice
206' ~—
\ 10 2"'
T
S `F
f`
' F
FA
LOWEST
FF - 199'
210'
X 199'
x 199'
�I
SITE PLAN
SCALE 1' = 40'
EXrSTINC #PROPOSED
DRA11yACE PATTERN
2
f
Qts.
150'
159.58
41a ._.. RT .s!
AEL E. ANDER:
No. CE -4781
oN 1
, \
u,
C. OR4f S >�755�,
50 Long x 5' P' de 150'
x 4' ;Effective Depth
T Absorption Trency,
Zoe• x I I
/ I ,Four Bed
TH B Home
It 1
o,°„ i 1®250 Gallon
o I Septic Tonk
C!
/
o er v
er
! Line Ice
206' ~—
\ 10 2"'
T
S `F
f`
' F
FA
LOWEST
FF - 199'
210'
X 199'
x 199'
�I
SITE PLAN
SCALE 1' = 40'
EXrSTINC #PROPOSED
DRA11yACE PATTERN
2
f
Qts.
150'
159.58
41a ._.. RT .s!
AEL E. ANDER:
No. CE -4781
LOT 29, BLOCK 3, SKY HILLS SUBDIVISION, PHASE 3
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom House 5' Wide Trench System
Perc. Rate: 2.5 Min.Anch 1,250 Galton Septic Tank
Application Rate: 1.2 GPD/SF 4' Drainfield Rock
4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area
500 SF/5 LF (Width)' .5 (Red. Factor) = p0 LF Trench Length
THEREFORE: Construct a 50' Long x 5' Wide x 4' Effective Depth Absorption Trench.
Flow Line Elevation in Trench to be 5' Below Original Ground Surface. Total Depth to be
9' Below Existing Ground. Maintain 10' Separation From Water Service Line on Lot
Natural
Backfill
4'6"
Geotextile
6" t 4" Perforated
t PVC (Holes Down)
4'0" I I 11>� Drainfield Rock
5'
TYPICAL 5' WIDE TR
(NO SCALE)
ENCH SECTION
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater.
Minimum 10' Separation From Water Service Line.
Minimum 100' Separation From Surface Water or Streams.
Municipality of Anchorage
Department of Health & Human Services
825 L Street, Anchorage, AK 99502-0650
SOILS LOG - PERCOLATION TEST
Performed For: Bob Klein Date Performed:
Legal Description: I of 99 Block 3 Sky Hillc Phase III
SLOPE SITE PLAN
7�00EMW
0
aP
Ln
dP
7
8
Date Gross
Time
0'*: . 4918
1500...
1
Was Groundwater
9
.5"
Fine Sand Encountered? No
16
10
If Yet, What Depth?
10
9:56
Some Silt Depth to Water
.5"
4
After Monitoring None
11
5.5" 5-
Date: 10/10/99
1
9/29/99
5 5%
L
P
E
Reading
Date Gross
Time
0'*: . 4918
1500...
1
4f�k�i
.5"
Q o : MICHAEL E. ANDERSON o- d
16
10
CE -4301 . .
17
9:56
41,
.5"
4
10:06
10
5.5" 5-
5
18
Bottom of
6
Hole
10
9/29/99
5 5%
L
P
E
Reading
Date Gross
Time
Net
Time
Depth To Net
Water Drop
1
29 -Sep 9:45
.5"
2
9:55
10
5.5" 5"
3
9:56
.5"
4
10:06
10
5.5" 5-
5
10:07
.25"
6
10:17
10
5.25" 5"
Perc. Rate: 2 Min./Inch Perc. Hole Diameter: 6"
Test Run Between 6 Ft. and 7 Ft.
Comments: Percolation Cavity Presoaked Prior to Testing.
Performed By: Fd Sanderson. I, Michael . Anderson, Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 10/25/99
T
Municipality of Anchorage
Department of Health & Human Services
825 L Street, Anchorage, AK 99502-0650
SOILS LOG - PERCOLATION TEST
Performed For: Bob Klein — Date Performed: 9/29199
Legal Description: I of 29 Block 3- Sky Hills Phase 111
SLOPE SITE PLAN
1 OG/PT
2
3
TESTHOLE No.
O 29-3-13
4
5
Fine Sand
71 1 Some Silt
8
Date Gross
Time
.,•OF At%1a
fj
Depth To Net
Water Drop
1
Was Groundwater
9
.5"
Encountered? No
15
10
If Yet, What Depth?
10
F
SP Depth to Water
16
4
After Monitoring None
11
2.5" 2"
Date: 10/10/99
13
Date Gross
Time
.,•OF At%1a
fj
Depth To Net
Water Drop
1
1E-•••.....Cq
_��'� • I�J•;s�I�e
14No
.5"
4911' % •.v
15
10
2.5" 2"
3
F
f+ : µIrJra EL t. A\CE0.50N;
16
4
`�'•, CE -4331.
17
2.5" 2"
4441 0
11:37
18
11:47
10
19� I Bottom of
Hole
58
?S$r
Reading
Date Gross
Time
Net
Time
Depth To Net
Water Drop
1
29 -Sep 11:15
.5"
2
11:25
10
2.5" 2"
3
11:26
.5"
4
11:36
10
2.5" 2"
5
11:37
.25"
6
11:47
10
2.25" 2"
Perc. Rate: 5 MinJlnch Perc. Hole Diameter: 6"
Test Run Between 6 Ft. and 7 Ft.
Comments: Percolation Cavity Presoaked Prior to Testing.
Performed By: Fd Sanderson. I, Mi .ha .I E Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 10/25/99
Sheet5
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 29, BLOCK 3, SKY HILLS SUBDIVISION PHASE 3
GENERAL:
The scope of this project includes the procurement and placement of a
new 1,250 -gallon tank at the location shown on the site plan. Work
also includes the construction of a new absorption trench 50' long by 5'
wide by 4' effective depth also at the location shown on the Site Plan.
The total depth of the trench will be 9' below existing ground and the
distribution pipe will be placed at 5' below the surface. All components
of the new absorption trench and septic tank must be constructed a
minimum of 100' from any surface water or 10' from the water service
line on the lot. A minimum of 4' of cover is required over the septic
tank and 3' over the absorption trench. In lieu of cover 2" of direct bury
insulation and 2' of cover may be placed.
2. Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
4. Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
A new 1,250 -gallon septic tank must be procured from a certified
septic tank manufacturer if the existing tank is found to be defective.
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
Lot 29, Block 3, Sky Hills No. 3
May 7, 2003
Page 2 of 3
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
6. Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
Lot 29, Block 3, Sky Hills No. 3
May 7, 2003
Page 3 of 3
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as -built of the completed system.
Municipality of Anchorage
Development Services Department R
Building Safety Division
On -Site Water and Wastewater Program
4700 Bragaw Street s" '
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 011-122-61 COSA # USC 11 I`
Expiration Date: I- 3~ V3
1. GENERAL INFORMATION
Complete legal description Lot 29, Block 3, Skyhills
Location (site address) 8323 Sky Mountain Circle Anchorage, AK 99502
Current Property owner(s) James and Patti Donley
Mailing address
Lending agency
Mailing address
Real Estate Agent
8323 Sky Mountain Circle Anchorage, AK 99502
piling,Address
r.
Unless othetwise requested, COSA will be held by DSD for pickup.
r2.. NUMBER OF BEDROOM& Four (4)
Day phone
Day phone
Day phone
3. TYPE O#•WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well °.
❑
Individual On-site
✓❑
Individual Water Storage
❑
Individual Holding Tank
❑
Community Class Well
❑
Community On-site
❑
Public Water System
❑✓
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval
are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Address P.O. Box 240773 Anchorage, AK 99524
Phone 522-7773
Engineer's Printed Name Michael E. Anderson, P.E. Date 12/10/2011
5. DSD SIGNATURE
Approved for l bedrooms.
Disapproved.
Conditional approval for . bedrooms, with the following stipulations:
Attachments
COSA Checklist X
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Report
Other
By: Original Certificate Date: 1-3-12—
//
3-12
IRea 11/05)
Municipality of Anchorage
�• Development Services Department
Building Safety Division
\ _ On -Site Water & Wastewater Program
4700 Elmore Road
P.O. Box 196650
Anchorage, AK 99507
www.muni.org/onsite
(907)343-7904
CERTIFICATE OF ON -.SITE SYSTEMS APPROVAL CHECKLIST
z9
Legal Description: Lot Block 3, Skyhills Subdivision No. 3 Parcel ID: 011-122-61
A. WELL DATA
Well type AMU
Date completed
Total depth ft.
Date of test
Static water level
If A, B, or C provide PWSID #
Sanitary seal (Y/N) _
Cased to ft.
FROM WELL LOG
ft.
Well Log (Y/N)
Wires properly protected (Y/N)
Casing height (above ground) in.
AT INSPECTION
ft.
Well production g.p.m. g.p.m.
WATER SAMPLE RESULTS: --
Coliform colonies/100 mL Nitrate mg/L
Arsenic: _ ug/I Date of sample: Collected by:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel Date installed 7/22/2003
Tank size 1,250 gal. Number of Compartments Two Cleanouts (Y/N) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N
Date of pumping 7/20/2011 Pumper A Plus Home Services
C. ABSORPTION FIELD DATA
Date installed 7/23/2003 Soil rating (g.p.d./ft2 or ft2/bdrm)1.2 GPwSF System type Deep Trench
Length 32 ft. Width 3 ft. Gravel below pipe 8 ft.
Total depth 14-15 ft. Eff. absorption area 512 ftz Monitoring tube Y Depression over field N
Date of adequacy test 12/9/2011 Results (Pass/Fail) Pass For 4 bedrooms
Fluid depth in absorption field before test 6.5 in. Water added 603 gal. New depth 9 in.
Elapsed Time: 120 min. Final fluid depth 6.5 in. Absorption rate >= 600 g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date
D. LIFT STATION
Date installed Size in gallons
"Pump on" level at _ in. "Pump off' level at _ in.
Datum Cycles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Manhole/Access (YIN) _
High water alarm level at
Meets alarm & circuit requirements?
r1l
Septic tank/lift station on lot >100'
On adjacent lots >100'
Absorption field on lot >100'
On adjacent lots >100'
Public sewer main NIA
Public sewer manhole/cleanout N/A
Sewer /septic service line >25'
Holding tank N/A
Animal containment areas >50'
Manure/animal excrete storage areas >100'
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >5'
Absorption field >5'
Water main NIA Water service line
>10' Surface water >100'
Wells on adjacent lots >100'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line >10' Building foundation >1Y Water main >10'
Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >25'
Curtain drain None Noted Wells on adjacent lots >100'
F. COMMENTS: Property is Served by AW WU Water System.
G. ENGINEER'S CERTIFICATION
l certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 12/10/2011
COSA Fee $ 640t to
Date of Payment \ )-- \ -,)-- ,i \ C4
Receipt Number 0a G\
(Rev. 11105)
Waiver Fee $
Date of Payment
Receipt Number
r �+ 49m
AB S ANDSWN . W
CE e 4381 .• �2�'�
�2 IC • rr,• E��i
pPO FE5510�a
99-140
SKYHILLS SUBD., PHASE
LOT 29, BLOCK 3
40,119 S.F.
3
FINAL STRUCTURE AS -BUILT
AS -BUILT
GASTALDI LAND SURVEYING
JEFF A. GASTALDI, R.L.S.
4726 WEST 88TH AVENUE
ANCHORAGE, ALASKA 99502
PHONE 248-5454
GRID DATE
2222 5/10/2004
F. B. JOB NO.
04-01 SHS3293
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND THAT NO
ENCROACHMENTS EXIST EXCEPT AS INDICATED.
IT IS THE RESPONSIBILITY OF THE OWNER TO
DETERMINE THE EXISTENCE OF ANY EASEMENTS,
COVENANTS OR RESTRICTIONS WHICH DO NOT
APPEAR ON THE RECORDED SUBDIVISION PLAT.
UNDER NO CIRCUMSTANCES SHOULD ANY DATA
HEREON BE USED FOR CONSTRUCTION OR FOR
ESTABLISHING BOUNDARY OR FENCE LINES.
ANCHORAGE RECORDING DISTRICT, ALASKA j
NOTE: NO CORNERS SET THIS DATE.
1 "= 40'
OF �1
AW 49- YYYVVV .9
..................: �`• A
............0
•W : erY A. astaldi
IP
. srP �S-609 • �°
�. rafos'jonat Va" .�
fill
it