Loading...
HomeMy WebLinkAboutDAWN LT 108[)awn Lot 108 #051-061-51 Municipality of Anchorage On-Site Water and Wastewater Program • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181245 PID Number: 051-061-51 Dwelling: ❑ Single Family (SF) Z Duplex (D) ❑ Multiple(SF and/or D) Project: ❑ New ® Upgrade Name: ELI RUSHING ABSORPTION FIELD - EXISTING Address ® Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound 21706 Morning Drive, Chugiak, AK 99567 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 6 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot Ft. Ft. DAWN 108 Fill added above original grade Gravel length Township Range Section Ft. Ft. Gravel width Beds: Number of Lines I Distance between lines SEPARATION DISTANCES Ft. -- -- Ft. To Septic Absorption Holding Sewer Total absorption area z From Number of trenches Dist.between trenches Tank Field Lift Station Tank Line Ft -- -- Ft. Well 200+ -- -- NA -- TANK ® Septic 0 S.T.E.P. 0 Holding 0 Other Manufacturer Capacity Surface Water 100'+ -- -- NA Anchorage Tank 2000 Gal. Material Number of compartments Lot Line 5'+ -- -- NA Steel 2 NA LIFT STATION Foundation 10'+ -- -- NA Manufacturer Capacity Gal. Curtain Drain NA -- NA NA Pump on level at 'Pump off level at High water alarm at Remarks *None known. New 2000-gal S.T. Installed per code. in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank 3034 Tank to 3034 Installer JRs - Flintstone drainfield Drainfield CO/MT 3b34 Inspector ARCTERRA BENCH MARK (Assumed elevation) 100 ft Inspection " 18/27/2018 2nd 8/28/2018 Location and description dates: e 4th Bottom of Siding COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL — Engigi n Ailik r <S. 444 \ , Conditional Approval: Date �� , 1, � * 4JT1_t /c * v ` KENNET 71116 rigcv or / i Approved L i,A , i . I Date c1/571 8 t \ �E si. �' eer's Stamp Inspection Report_9-1-12.doc AS-BUILT SYSTEM DETAILS/SITE PLAN Permit ❑SP181245 DAWN SUBDIVISION LOT A 1-ô3 PID# 051-061-51 I N89'55'20"E 159.44' (159.49' REC) 0 • x x a 11.4' 24.0' '�� LOT 108 0 EM 9,p -Pt 4 °I c°F� 4 RAYEI 0 x ��OF�'1' o.F G� 0 000 x 24.0' 4 �x ,4 NIN yt^ (� N .5' N A 33xI 2 _ u 4 R . �-J == NC6.0' �x �IIll, EXISTING 6-BR DUPLEX N :871 O CO FCO V (.11 C0� c • • O r D C m 39.5' Z7 / B • CANT m <x ; x .� NEW 2000-GAL S.T.,& CONNECTED TO EXISTING FIELD. m o K x x 54.5' — N89'55'20"E 159.44' (159.49' • - x—x—x— _____x—x —� SCALE' 1' = 30' 3 0 A—C=18,2' 98.50 98,60 B—C=12,8' - A—D=28,7' W o ,, 0 Le N B—D=26.2' _ FINAL GRADE — i I11VARIES 0 — 'Al --'2000—GAL a3 CT SEPTIC m 'v TANK EXISTING FIELD t` 92,04 91,87 _ I U 0 _ a _ v, �F ��\ SCALE' NTS ��_ . .�5. 1 PREPARED FUR CTE W R R . /�� -.b.A...- 7 1 ELI RUSHING �o� ������\� �s`�� N• /* / • TH /\ * CHUG MORNING 56IVE a �,�� .'�„\ �� CHUGIAK, AK 99567 m v / • dedigifA��� ir' � a ro / KENNE "� I �S / FIELD BOOKS COMPUTED: 1111113•1111111 • ` CE-71 6 - BOUNDARY: DRANK: Z l N• W / N/A BMW 111� C�:��`�,. 41't j� /,� 18 STAKING: N/A CHEa<ED: KND �� .� " f,(j ,`, �' ASBUILT: SLS DATE: 8/30/18 � °'''„G, ���,� .�,� �� \W'C FESSIO�� DWG. FILE: GRID: NW1461 cFR pNs Sty. ,,sz> Z ��� "CAD FILE: FILE oB "°: 18-172 SFR A 19IN ,1 56 MORNING DRIVE in CV N00'04'00"W 125.22' (125.40' REC) C a 1 1 X in x 1 W /711 1 1 CCX Cli 29.I \ 3' LO v 28.0' A 0) cF I : > . Oi / , X �) ! w r 0 J ` ai 1--I h to M, - to 4J co S 117 H I 1 0 CD N i 7.3' GRAVEL c> j O/w DECK ,0 20.7. W8'1 27.9' t,, 111 W O I _J O NN 0 10 IP IP (7) \CO T--- / CA Z Z 31.0' 0• SEPTIC { VENT OP) t 0Pev q r �QQ� N o C c r. 31.6 K -- —_. --- i 10' UTILITY SMT �I 1 ESMT k -X- .-- ----X-X-X-XN00`�'UO"�....X X --125.`'22-" _( 25:`40-'REG X—X*X X 1 • ANCHORAGE RECORDING DISTRICT,ALASKA AS-BUILT OF: DAWN SUBDIVISION O END 5/8"REBAR LOT 108 PLAT 71-151 'd�,e�``\ � SURVEY CERTIFICATE: I,John L.Schuller,Have conducted a . .G� OF A T �i physical survey of this property as shown on this drawing and that the ,/'' r IS: •.•'' .4 A 1k'� improvements situated hereon arc within the property lines and no ,`` enchroachments exist other than noted.Under no circumstance should /f �. 49� 1 any information on this drawing be used for construction of fences. * r * 4 ft structures,improvements,or for establishing boundary lines. I a / r p EXCLUSION NOTES:It is the owners responsibility to determine 4. .`g•' . ' "'"" / 4111- `~'ti .\ the existence of any easements,covenants,or restrictions which , �, '•J L. S R. • • 4!)-', 1 not appear on the recorded subdivision plat. 1 I7P •! LS-10408 _P f� "1/4-...„..„,.....- do WORK ORDER NUMBER WE: scab e-►ru, •Cis @ ^ • 5°• �� 1831 Talkeetna Street AUG 30, 2018 1"=20' IWCY,:, &.$C''>8,ENa.. Anchorage, Alaska 99508 18-043-2 DRAM BY:DNEC ED BY.01°o NUMBER: BOCK/PAGE: tN~ofessiono\ \'o"�"aro (907) 227-1455 office JLS NW1461 180220 ��������� (907) 274-4992 fax MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program takee\ PO Box 196650 4700 Elmore Road %. 47N I Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 r http://www.muni.org/onsite )(•;t:Pin:::1111; 44,CMa 0*. On-Site Wastewater Disposal System Permit Permit Number: OSP181245 Effective Date: 8/7/2018 Work Type: SepticTank Upgrade Expiration Date: 8/7/2019 Tax Code Number: 05106151000 Site Legal Address: DAWN LT 108 G:1461 Site Mailing Address: 21706 MORNING DR, Chugiak Owner: RUSHING ELI R & COURNTEY E Lot Size in Sq Ft: 20000 Design Engineer: ARC TERRA CONSULTING INC Total Bedrooms: 6 This permit is for the construction of: ❑ Disposal Field D Septic Tank ❑ Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Date: Issued By: wi� Cs.,ous ?JDate: gi 17 -_r MUNICIPALITY OF ANCHORAGE ra Community Development Department '/ Phone: 907-343-7904 p Develo ment Services Division = � Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-061-51 ELI & COURTNEY RUSHING 865-6500 Property owner(s) Day phone Mailing address 22432 McMANUS DRIVE, CHUGIAK, AK 99567 21706 MORNING DRIVE, CHUGIAK, AK 99567 Site address _ Legal description (Sub'd., Block & Lot) )O I/,/ LOT 108 Legal description (Township, Range & Section) Lot Size 20,000 Sq. Ft. Number of Bedrooms 6 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field I Initial I I Single Family (SF) ❑ (w/wo ADU) Septic Tank Upgrade [ Duplex (D) Holding Tank n Renewal n Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage _ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signatu property owner or authorized agent) Permit/Rush Fees: 2.16— Waiver Fees: Date of Payment: F'2.- IF Date of Payment: Receipt Number: ()Q1,57 Receipt Number: Permit No. OS? IT I24'S Waiver No. Permit App_9-1-12.doc roRCTE/ m ARC 1 ERRA • : CONSULTING, INC %. % j 212 E. 51st Ave,Anchorage,AK.99503 4`1. Office(907)868-3791,Fax(907)868-3793 0ps,s"•�0. ofce 441-4.�c wenTING. -a' July 31, 2018 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: SEPTIC TANK UPGRADE PERMIT DAWN LOT 108 The owner has requested we proceed forward to obtain a septic permit to upgrade the aged septic tanks. We propose to decommission the existing tanks per code and install a new 2000-gallon tank to serve the existing 6-bedroom duplex. The subject and adjacent lots are served by public water. There is no surface water within 100' of the proposed tank. We do not expect there to be any adverse effect on adjacent lots by the development of this tank. If you have any questions, please contact me at 868-3791 / FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. miaow- Kenneth M. i s, P.E. Attachments: On-Site Sewer Design Application 20441 PTARMIGAN BLVD • EAGLE RIVER,AK 99577-8736 • PH(907)868-3791 • FAX(907)868-3793 WASTEWATER DISPOSAL SYSTEM DETAILS/SITE PLAN DAWN SUBDIVISION LOT 108 X z _ GRAVEL x DA 2 15.5' 4.0' NI 9 0 33.5' • c x •Ai nit z 1'! »rMIu ,J P NNoir t�'..WI W 6.0' 2. ,11111., r..1 NI EXISTING o 0 U'�x .--4N •I I -wl--a 6-BR DUPLEX El O J C 1"-, I cos 4. 0 Frl E FCO co 3( CO CO 39.5' In CANT x K DECOMMISSION EXISTING S.T.B, -I INSTALL NEW 2000-GAL. S.T., FCO, POST TANK COB, & N x CONNECT TO EXISTING FIELD. tv I° I MAINTAIN 10'+ FROM FOUND., °. w x 5'+ FROM DECK SUPPORTS, I 10' FROM WATER SERVICE UNE. & ANY OTHER SETBACK REQ. Scale: 1"— 20' x -X—x—x—X—X-1X—X—X X X X IX X X—X—X—X—Y-'--'1 54. N89.55'20"E 159.44' (159.49' RI-EC"). LOCATE & STAKE WATER SERVICE LINE PRIOR TO CONSTRUCTI❑N & MAINTAIN 10'+ SEP. FLAG ALL WELL RADII DESIGN DETAILS & LOT LINES PRIOR DECOMMISSION EXISTING 1000 & 750 GALLON SEPTIC TANKS TO CONSTRUCTI❑N INSTALL 2000-GAL. SEPTIC TANK & CONNECT TO EXISTING SYSTEM. INSTALL FCO 8, POST TANK COs.. NO PUBLIC WELLS WITHIN 200' OF NOTES: PROPOSED SYSTEM. NO PRIVATE WELLS WITHIN 200' 01 1. CONNECT TO EXISTING SYSTEM AFTER POST TANK COs. PROPOSED SYSTEM EXCEPT AS NOTED. NO SEPTIC SYSTEMS WITHIN 200' OF 2. INSULATE TANK WITH 2' HD BURIAL FOAM WHEN LESS THAN 4' PROPOSED WELL EXCEPT AS NOTED. COVER. ALL PROPERTIES SERVED BY PUBLIC WATER 3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INT❑ SEPTIC TANK. 4. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS, SEPTICS, LOT LINES, FOUNDATIONS AND ALL OTHER SETBACKS, 4.80..__`N Or �Aliir� OF �.A.,s, 1 PAGE 1 OF 1 ,<S< PREPARED FORt . � 7 1 ELI RUSHING g-- 'k J? * . TH * 21706 MORNING DRIVE a(If ,9 ref/ & / CHUGIAK, AK 99567 .4+°/ • KE t i, / FIELD BOOKS COMPUTED: a /CE-71 ,�� ' 1 / BOUNDARY:N/A DRAMN: BMWc 1.4 :`�• / : l' �B STAKINGN/ACHECKED: KNO • \ k1 4,,nn�����•/ � ASBUILT: SLS DAT' 7/31/18 -N' • �- ,{��RonssiQT1 / \` e1rDWG. FILE GAO: N W1461 (FRc b,,, ,,c, t� \``_ ,,fA (�LTINC .�.y0 ACRD FILE:FILE ''DB M 18-172 • "k•2957'' MORNING DRIVE 10 ''......1111C.1q la' N N00'04'00"W 125.22' (125.40' REC) ® 4 x In LOT 108 I U x w I x d- U LI of u7 29.3' CA 28.0' Crf u) L a Cn U 10 iA ;� M EXISTING In HOUSE Mr ai z to 0 f..t GRAVEL 7.3' 0/W DECK 20.7' 27.9' LLI 111111 b 'IIIIO N N 10 10 P SEP11C • IP Z co Ow) Z I 31.0' 0 GARAGE/BARN N N 31.0' it 10' UTILITY ESMT 29.4' —X—X x—X—x—XNO6.-0-40"WV ' X—X—I25."22 X- 25."40r' Z — EC X—X—Xx ANCHORAGE RECORDING DISTRICT,ALASKA AS-BUILT OF: DAWN SUBDIVISION =FND 5/8"REBAR LOT 108 PLAT 71-151 40. _``"� SURVEY CERTIFICATE:I,John L.Schuller,Have conducted a i ' ICI F' A��N y� LANDD S physical survey of this property as shown on this drawing and that the / .:6tvt, 4.g10 Sr„.1,2 improvements situated hereon are within the property lines and no /�c��'• -,1— �` ��� f t'`�t, enchroachments exist other than noted.Under no circumstance should % . 49TH /\ % ,f N� �� any information on this drawing be used for construction of fences, / ,):: l c % structures,improvements,or for establishing boundary lines. d �' / U 41 r4 r-. EXCLUSION NOTES:It is the owners responsibility to determine Oi•73 . co . IN L. SCHULLER.: o/ i . •,) the existence of any easements,covenants,or restrictions which /I. �,� ,. • s LS-10408 .a0 •+..•...,.r" do not appear on the recorded subdivision plat. ,1 � ••. .• / woRc � NUMBER: ONE: SCALE E-r� o e • �J�/ 1831 Talkeetna Street 1% a .''Z!.1I•cg. i % Anchorage, Alaska 99508 JU18-043 IAVIYe 2018a(�trriato mom 0' eoac/P . `�\�ofessionot o� (907) 227-1455 office JLS NW1461 180171 \����V�` (907) 274-4992 fax MUNICIPALITY OF ANCHORAGE n Heal 'and Environmental Protec tin Fourth Floor West 825 L Street Anchorage, Alaska 99501 264-4720 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME VI�K./_i �MAILING ADDRESS S.1-Js1F a�p 1� _PHONE -Wa�'- a6a 1rAy LOCATION ALL.LC} �"tk LEGAL DESCRIPTIONJA ^^ •�` -O n'� SEPTIC TANK: 'fin A w DISTANCE NUMBER OF FROM WELL �L//OOII• MANUFACTURER l:VMATERIAL COMPARTMENTS Z IOOd INSIDE LENGTH INSIDE WIDTH - LIQUID DEPTH LIQUID CAPACITY— GALLONS. TILE DRAIN FIELD: LL aarllv-^� (yam ] 1 1 t TOTAL LENGTH 1 DISTANCE FROM WL"LL "�-F FOUNDATIONS NEAREST LOT LINE Z'� OF LINE q� # of Lines I DISTANCE BETWEEN LINES --/-J(LTRENCI4 WIDTH IN. TOTAL EFFECTIVE ABSORPTION AREA _SP O Z SQ. FT. LENGTH OF EACH LINE DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE.—MATERIAL BENEATH TILE IN. ABOVE TILE Z IN. SEEPAGE PIT: DIAMETER _ OR WIDTH _. LENGTH_, DEPTH Log Crib _Rings_ Crib Size:' DIAMETER—DEPTH— DISTANCE FROM: WELL -' TOTAL EFFECTIVE BUILDING FOUNDATION_, NEAREST LOT LINE ABSORPTION AREA (WALL AREA) SQ. FT. well Class: Vkz0 Depth: Well Distance To: Lot Line _ Bldg: Sewer Line: Pipe Materials: a.. a # of Bedrooms: Installer: Sat Remarks: So11 -too 1 12 oo12' DATEL_!1_/_J APPROVED fN c� J-- J �P h��- v "P l� �C a 'Ik , Lo -e DATEL_!1_/_J APPROVED fN c� M U N I (-_ I F?%+-IFL I TY OF F=l IJCHOF-:F=l GFEE pM DEPARTMENT 0 AEALTH AND ENVIRONMENTAL F___),TECTION A. w �_i1 825 'L' STREET, ANCHORAGE, AK. 995. + 279-2511 OrJ-SITE SFEE WFEE FZ F-E:FZM I T ---�- M PERMIT NO. C 77703 ) ` $T �KNyto\ 0 -I 71 APPLICANT JACK FRRP1 BX. 278 CHUGIRK 688-2024 LOCATION CHUGIAK 0-kASn LEGAL LT. 108 `4(cncv+4A-+T-5 LOT SIZE 23000 SQUARE FEET TYPE OF SOIL ABSORBTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS = 6 SOIL RATING (50 FT/BR)= 100 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: aEF1TH= :3_2 LENGTH= 43 C3F2RVEFL r>EFaTH= 7 THE LENGTH DIMENSION IS THE LENGTH CIN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION CIN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFALL PIPE AND THE BOTTOM OF THE EXCAVATION CIN FEET). FZE(;!U I FRE[] SEF}T I C: TRr-AF'. S I ZE= 1 750 GFiLLOr-JS --------- F='Fl( F_KnGE F}FLFIN-r OPTION ------- A PACKAGE PLANT MAY BE INSTALLED AT THE PERMITTEE'S OPTION SUBJECT TO THE FOLLOWING CONDITIONS: 1. EITHER A CLASS I OR II NSF APPROVED PLANT MAY BE INSTALLED. 2. A CONTINUOUS MAINTENANCE AGREEMENT IS REQUIRED. IF A MAINTENANCE AGREEMENT IS NOT KEPT CURRENT YOU MAY BE REQUIRED TO ENLARGE THE SOIL ABSORPTION SYSTEM AND/OR YOU MAY BE SUBJECT TO PROSECUTION. -------------------------------------- --- ------------------------------------- --- TWO <Z_2> I NSP EC T I ONS RFRE FREGtU I FREC> - BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 200 FEET FOR A PUBLIC WELL. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. P EFRM I T EXP' I FRES F3rECEME3EFZ 311 1 377 I CERTIFY THAT 1: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND -WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. 3: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 6 BEDRO PIS. SIGNED :_L R=--------------------------y-y- RPPL PaCK FARMER__ISSUED EY_ _ ____ __ _____ 0 £t E GEOT CHNI CAL Et DEVELC WENT CO. Box 90, Davis St., Eagle River, Alaska 99577' ' 694-2774 or 6882280 - Russe// Oyster fad Ellis 694.2774 SOIL LOG - 688-2280 Soils 8 Foundations �,n Land Development Performed for: Name: �� � P,CA<-- ..fn, Tel. No., LA—Z(jZ9' Mailing Address: ��,c tdwD Ak a°,SWZ Legal Description: N- ,&-r WON �S' %.^q� Depth (feet) — Soil Characteristics o WKvx � 2GAJ.ca 2 3 t U 5 r 6 7 8 9- 10 to 11 . 12 � `�S' �•A�a.r CaTs451�s -co 1'1� �Je N+s 13 lb 15-- 16 Ground Water Encountered: Yes No ✓ If yes, what depth Proposed Installation: Seepage Pit Drain Field 1.1 Comments: �� tc\4,l,2ac,, R. ' 17 ML 3t �.�:� , •' -. " - Q.,..� 'S . � t � 1-a c atn—�•..._ S� rte. Performed by: ss OIA. s14Ri Date:_ \) a t �75,/t I �Z-I�ys 04)1oc,Ps ctC,r�\;c,Yucl � . / ,-_1 - -,�; � '�. ;,•�- 1, GAAB HDI . GREI'R ANCHORAGE AREA BOROUC4"'N DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TUDOR ROAD ANCHORAGE, ALASKA 89507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME 1eM I�CVLi`" • MAILING c• /o"" SCOD;T -ADDRESS,�PHONE LOCATION +lH44 LEGAL DESCRIPTIONzy/cs An&'y Sub SEPTIC TANK: DISTANCE FROM WELL CLOT LIQUID CAPACITY / e7rr GALLONS. SEEPAGE SYSTEM: SEEPAGE PIT: ,s/Ec/ f=a6r� INSIDE LENGTH INSIDE r LIQUID DEPTH NUMBER OF PITS �aI OUTSIDE DIAMETER OR WIDTH_(,?LENGTH 13 , DEPTH 6 LINING MATERIAL �Q J 6,xtl . DISTANCE FROM WELL , BUILDING FOUNDATION NEAREST LOT U '3 NE 3 c TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) -51Z SO. FT. TILE DRAIN FIELD: DISTANCE FROM WELL NUMBER OF ABSORPTION BETWEEN LINES FT. LENGTH OF EACH TOTAL LENGTH NEAREST LOT LINE , OF LINES , TRENCH WIDTH IN. TOTAL DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL; �CI11MtlK! DISTANCE FROM WATER TYPE DEPTH ,BUILDING FOUNDATION. SAMPLE , NEAREST NEAREST SEPTIC SEEPAGE OTHER LOT LINE , SEWER LINE ,TANK , SYSTEM , CESSPOOL . SOURCES_ DIAGRAM OF SYSTEM • DISTANCES: Y• 33 oft ` ' \ fe-t. DATE c0��t `�� //�/ APPROVE G.A.A.B. M N- GREATER ANCHORAGE AREA BORC.LJGH DEPARTMENT OF ENVIRONMENTAL QUALITY 9700 TUDOR ROAD POUCH 6.650 ANCHORAGE. ALASKA 99302 TELEPHONE 279.8686 SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT NAME OF APPLICANT INSTALLATION LOCATION LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH SOIL TEST RESULTS COMPLETION DATE ANTICIPATED MAILING ADDRESS SEEPAGE PIT PERMIT NO. PHONE DRAIN FIELD OTHER TO BE INSTALLED BY NOTE, THIS PERMIT 15 NOT VALID WITHOUT SOIL TEST FINAL INSPECTION, 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE HEALTH DEPARTMENT AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE TYPE SEEPAGE AREA SIZE TYPE MINIMUM DISTANCES. REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK . SEEPAGE PIT DRAIN FIELD " TO NEAREST LOT LINE. WELL TO SEPTIC TANK SEEPAGE PIT DRAIN FIELD ALSO CONSIDER AREA WELLS. 1 . WATER MAIN TO SEPTIC TANK SEEPAGE PIT DRAIN FIELD . SEPTIC TANK.` SEEPAGE PIT DRAIN FIELD TO RIVER. LAKE. STREAM. CAST IRON, INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SELPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. HEALTH AUTHORITY OR LICENSED DESIGNER DIAGRAM OF SYSTEM 1 CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28.68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATE APPLICANT'S SIGNATURE �� f.RF.AT'L'R AAC'r'^,?F.^•r r • r' H£ALTI1 '0""A, 7 `'ENT 327 L'AoG!'; STRECT ANCHORA.^..E, AL.;^1<A 9991 Perfcrmed For o Leval Ucscription: Lot �nICY; Pr Date er: This Fcra Reports a: Soils Lo^ ��rercolz Depth • Feet sci.i C?ar•. Was Ground Water Encountered? V1 0 If Yes, At What Depth CASE if Locaticn Skotrh Frcposcd instal tatT ;'SEepage Cit Depth 3 Drain field p Of Ir.iet io Bottoms Of !'it Cr Trtnc?t t-:,•T"�""' E' �. . ?!'•1 L•TS' !• ti )—I+YY� hl i2 �t Test;Perfoirmed;By r A Data Certified to Da..�1 y RECEIVED MAR 5 1991 Municipality of Anchorage Dept. Health 8 Human Servicea ANCHORAGE DISTRICT OFFICE 3601 C STREET, SUITE 322 ANCHORAGE, ALASKA 99503 11r. Robert A. Shafer, P.E. S s S Engineering 17034 Eagle River Loop, Suite 204 Eagle River, Alaska 99577 563-6775 February 27, roP' RE& Lot 108, Dawn Subdivision, Peters Creek, Alaska,;ADEC Project Number 9121 -DA -0531 Review Dear Mr, Shaferr This is in response to your submittal, received in this office on January 22, 1991, in which you requested approval for the on-site wastewater disposal system and the connection to the Wynter Park/Meadowridge Estates Class A Public Water System (PWSID Number 211431). I have completed my review of the submitted information, this office's written and computer files on the existing public water system and have the following comments. The submitted information it appears that the wastewater disposal system was installed substantially in accordance with State regulations and guidelines at the time. The results of two adequacy tests, 1983 and 1990 (I am assuming that it is 1991 not 1990) also verifies that on the day the adequacy tests were performed the wastewater disposal system was accepting the necessary flows. Therefore, the wastewater Aisposal system is approved for the concerns of this Department. Th,e enclosed signed Approval of On -Site Residential Nater aria* Sewer Systems, constituting this approval, is enclosed for the existing wastewater disposal system. The six bedroom duplex is connected to Wynter Park Meadowridge Estates Class A Public Water System. This public water system is in compliance with the provisions of 18 AAC 80.060, State of Alaska Drinking Water Regulations. Although not sufficient to delay the above granted approvals, there appears to be a discrepancy between the two adequacy tests on just where the water was added to the wastewater disposal system during the adequacy tests. In the 1983 adequacy test,: it appears that the water was added to the trench with two septic tanks being monitoring, while in the 1991 adequacy test, water was added to the seepage pit. At this time, I am assuming that the seepage pit noted in your 1991 adequacy test is the 750 gallon second septic tank and the wastewater disposal system has not been modified without written plan approval. If this not the case,,_the above approval will invalid. Thank you for your cooperation with this Department. If you have any questions, please do not hesitate to call. Sincerely, Keven K. Kleweno Environmental Engineer Enclosure: As Stated r cc: \John Smith, DAHS, w/o Enc. KKK/skpf APPLLI;'INT FILLS OUT UPPER HA'" ONLY Property Owner JaC /f Time A 7 - Phonne Mailing Address 76 o / /�Pr ,t / 4 11x-1 Ar(" Zip Code �j Q % ; / ��� Buyer Ail �Q/ Le, Address —5a Zip Code „Ll f+0 Lending Institution Inspector Phone Address Zip Code Field Notes: P�^^,� Realty Co. d Agent 41;,57,9,, R Pu �1 1 ., 1 � 'Iy 2 � M � D IIIUIr_1111J1111 uU �[ U Phone 1 �/C///f��JO�CI APR %,� Address L/;,?/ WP•5� Zip CoO Legal Description !J /0? /J LtVx/ // Street Location -/0 Fj ,G ,�, � "Dept. of Heal) 6 Type of Residence Environmental Protection,' ( APPROVED BEDROOMS ❑ Single Family 'CONDITIONS OF APPROVAL ( ) DISAPPROVED X Multiple Family No. of Bedrooms ( ) CONDITIONAL APPROVAL' ❑ Other DATE Water Supply BY: ❑ Individual ATTACH WELL LOG. A well log Is required for all wells drilled since June 1975. ❑ Community For wells drilled prior to that date. give well depth (attach log if available). ❑ Public Uglily Septic Tank Size Sewer Disposal ,/f/,7 A Individual Year Individual installed: ❑ Public Utility When Connected to Public Utility: ❑ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REOUEST BEFORE PROCESSING CAN BE INITIATED. Time Time Time Time A 7 - Date Date Date Date 1. „Ll f+0 Inspector Inspector Inspector Inspector Field Notes: P�^^,� ✓ � �, �1 1 ., 1 � 'Iy 2 � M � D IIIUIr_1111J1111 uU �[ U �o� APR 111983 "Municipality of Anchorapo" "Dept. of Heal) 6 Environmental Protection,' ( APPROVED BEDROOMS 'CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONDITIONAL APPROVAL' DATE BY: Solis Rating Date Sewer Installed Well To Absorption Area Well Log Received Septic Tank Size Well to Tank r` EXCAVATION Jack Farmer 7601 Highlander Anchorage, Alaska 99502 WORK r`! April 19, 1983 Dear Mr. Farmer, Reference: Lot 108; -Dawn Subdivision ROBERT A.SHAFER CIVIL ENGINEER 694-2979 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRO" :NTAL PROTECTION MAY 19c? RECEIVED A sewer system adequacy test was performed on the system located on the referenced property, as you -requested. The septic tanks were pumped and verified to have a combined capacity of 1750 gallons. The absorption trench was tested by a continuous flow of water over a period of 48 hours without any adverse effect on the system. It can be concluded from this test hat the waste water disposAl system serving the six bedroom duple located on this property is currently functioning adequate However, the system cannot be guaranteed against subsequent failures. If we may be of further service, please do not hesitate to contact US. E. cc: Municipality of Anchorage Department of Health and Environmental Protection SRS 196X EAGLE RIVER, ALASKA • • � a • Municipality of Anchorage r :M;(t. On-Site Water and Wastewater Program < (907) 343-7904 SA TS`._ CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 051-061-51 Expiration Date: SQ.,p-t 5, O1 1. GENERAL INFORMATION Complete legal description DAWN LOT 108 Location (site address) 21706 MORNING DRIVE,CHUGIAK,AK 99567 Current Property owner(s) ELI &COURTNEY RUSHING Day phone Mailing address 22432 McMANUS DRIVE,CHUGIAK,AK 99567 Real Estate Agent Day phone 2. TYPE OF DWELLING: ❑ Single Family (w/wo ADU) ® Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 6 TYPE OF WASTEWATER DISPOSAL: 4. TYPE OF WATER SUPPLY: Individual Individual Well ❑ Holding Tank ❑ Individual Water Storage ❑ Community ❑ Community Class A Well ® Public Sewer ❑ Public Water System ❑ WaiverNariance request for: Distance: Received by: / .!/ ; I Date: J 3 __.. .. .COSA to be released.to_the:engineer,unless otheiwi'-s� ted by the engineer. COSA Fee $ - Waiver Fee $ 5 Date of Payment q-,3) 1 t Date of Payment / 5 .1 2 Receipt Number ba5.a a Receipt Number. 0 Li 7 COSA# (RC1' (4162- Waiver# OSV -1 ? ) o('7 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING,INC. Phone 868-3791 Address 20441 PTARMIGAN BLVD.,EAGLE RIVER,AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 8/31/18 THIS COSA DOCUMENT CANNOT BE USED TO TRANSFER TITLE UNLESS ALL VENDORS(ENGINEERING,SURVEYING,CONTRACTORS,ETC...ASSOCIATED WITH THIS COSA ARE PAID IN FULL AT OR BEFORE CLOSING. Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore,ArcTerra can riot give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen ���►\ encroachments,deficiencies or discrepancies exist. OF AL AX AP- i* 4. Tf-] ' i1�+s* # 6. DSD SIGNATURE r��., System#1 Approved for (0 bedrooms. moi r% KENNETH M.��`� Aff System#2 Approved for bedrooms. ,r=F� 3/ ,.'/ Disapproved. \ FEssto,s "k Conditional approval for bedrooms, with the following stipulations: ON-SITE • WATCR AND :D. WASTEWATER c PROGRAM By: f.6) ,(t,(7A auttE Original Certificate Date: S efE 5) 0 1 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations:given in paragraph_5-by.an.independent professionatcivil engineer registered in the State.of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 10-10-12.doc • If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system _ Certificate of On-Site Systems Approval Checklist 001-- 5( Legal Description: DAWN LOT 108 Parcel ID: 051-7+246- A. WELL DATA Well type A If A, B, or C provide PWSID#211431 Well Log (YIN) Date completed _ Sanitary seal (Y/N) Y Wires properly protected (Y/N) Total depth_ ft. Cased to ft. Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic: ug/L Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC 1 STEEL Date installed 8-27-2018 Tank size 2000 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping NA-NEW TANK Pumper C. ABSORPTION FIELD DATA Date installed 10/1977 Soil rating (g.p.d./ft2 or ft2/bdrm) 100 System type DEEP TRENCH Length 43 ft. Width 3 ft. Gravel below pipe 7 ft. Total depth 11 ft. Eff. absorption area 602 ft2 Monitoring tube Y Depression over field N • Date of adequacy test 7/612018 Results (Pass/Fail) PASS For 6 bedrooms Fluid depth in absorption field before test 0 in. Water added 1200 gal. New depth 11 in. Elapsed Time: 70 min. Final fluid depth 0 in. Absorption rate >= 900 g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N &type) N If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at_in. "Pump off" level at_in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES -CLASS A WELL ON LOT TO: Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer/septic service line Holding tank Animal containment areas Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 200'+ ABSORPTION FIELD ON LOT TO: ot Property line 10'+ Building foundation 49++ Water main 10'+ Water Service line 7.5'+/. Surface water 100'+ Driveway,parking/vehicle storage Ifir a t Curtain drain 50'+(NONE KNOWN) Wells on adjacent lots 200'+ F. COMMENTS NEW MT INSTALLED. LOCATED WATER SERVICE LINE 7.5'+/-FROM FIELD. A kJ kv E►t;S G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in _ conformance.with MOA COSA guidelines in effect on this date. .: OF AL\ Engineer's Printed-Name •KENNETH M.DUFFUS ' � . Date 8/31/2018 *-49TH l-.�.�.APO L OW ` � fe COSA canary sheet_2-6-15.doc � 7116 ssto — ,r • Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.orq/Onsite Development Services Department On-Site Water and Wastewater Section **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV181067 COSA#: OSC181452 Permit#: PID#: 051-061-51 Legal Description: Dawn Lot 108 Engineer: ArcTerra Applicant: Eli & Courtney Rushing Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the garage foundation and water service line has been approved. The approved separation distances are 0.0 feet and 7.0 feet, respectively. Reduced separations are existing conditions with no known issues; per engineer's waiver request letter. This waiver approval applies to the existing absorption field only. Any future upgrade to the on- site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: 1/5/1k Approved by: K,'t.t.19. C0_yrtJ12 Name of Reviewer **** VARIANCE/WAIVER REVIEW **** ,, �RCTERR� ,w 9' ARC 1m IRRA CONSULTING, INC ' �. . ' Q f 212 E. 51s'Ave,Anchorage,AK. 99503 c� cs,„StITI NG•l4�” Office(907)868-3791, Fax(907)868-3793 September 5, 2018 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Waivers —Dawn Lot 108 The subject water service line appears to be approximately 7' from the end of the existing leach field and the leach field appears to be under or near the existing on-grade, wood garage/shed/barn on grade The water service line and wood structure on grade has existed for what appears to be from the time the property was initially developed with no known issues. We are therefore requesting a waiver from the required separations be granted at this time and the COSA be issued as the MOA has done previously. We do not expect there to be any adverse effect on the subject or adjacent lots by granting this waiver. If you have any questions, please contact me at 868-3791 / FAX 868- 3793. Respectfully submitted, ArcTerra Consulting, Inc. enn- A .4, P.E. 20441 PTARMIGAN BLVD • EAGLE RIVER,AK 99577-8736 • PH(907)868-3791 • FAX(907)868-3793 • Municipality of Anchorage 4,8'' On-Site Water and Wastewater Program(907) 343-7904 Certificate of On -Site Systems Approval Parcel I.D. 051-061-51 Expiration Date: Jf - % (0 1. GENERAL INFORMATION Complete legal description Lot 108, Dawn Location Mailing address Real Estate Agent 1706 Mornng Drive Jessica Anderson Day phone (907) 317-4433 21706 Morning Drive Chugiak, Alaska 99567 Lisa Huston @ Eagle River Realty Day phone (907) 441-5375 2. TYPE OF DWELLING: ❑ Single Family (w/wo ADU) Fx_1 Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 6 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual I] Individual Water Storage ❑ Holding Tank ❑ Community Class A Well El Community ❑ Public 1,^ .ter System ❑ Public ce,..e. 4.l is QY .pl ❑I WaiverNariance request for: the engineer, unless otherwise requested by the engineer. COSA Fee $ Lf'lt)J Date of Payment 7 gLf l 3 2ft5� Receipt Number I ke 3S1 3 COSA # 0511 1:3\;114 Date: -` ZC—i-1 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Address Pinard Engineering PO Box 871347 Wasilla, Alaska 99687 Engineer's Printed Name Paul E. Pinard, P.E. 6. DSD SIGNATURE _�/�System #1 Approved for bedrooms System #2 Approved for bedrooms Disapproved Phone (907)357-3647 Date Conditional approval for bedrooms, with the following ®OORfl9WQ9®Rr i!@m3 ew PCti,e%"71 /� s By: / Original Certificate Date: Theme lit f ®rage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA blue sheet r'- . c Nitrate Advisory., . Arsenic Advisory Other l�T If more than 1 septic system is on the lot: COSA Checklist # 9 of I Structure served by this system i Certificate of On -Site Systems Approval Checklist Legal Description: Lot 108, Dawn Subdivision A. WELL DATA Well type Community If A, B, or C provide PWSID # 211431 Date completed _ Total depth ft. Date of test Static water level Well production Sanitary seal (Y/N) _ Cased to ft. FROM WELL LOG WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate Arsenic ug/L Date of sample: B. SEPTIC/HOLDING TANK DATA ft. 9-P m. mg1L Parcel ID: 051-061-51 Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) in. AT INSPECTION Collected by: ft. g.p.m. Tank Type/Material Septic/Steel Date installed 10/77 t 750 (2) 2 Y Tank size gal. Number of Com a ments _ Cleanouts (YIN) ep-p �I2''/(y, Foundation cleanout (Y/N) _, eY&essidn over tank (Y/N) N High water alarm (Y/N) NA Date of pumping 8/2/12 Pumper Sanitary Pumpers C. ABSORPTION FIELD DATA Date installed 10/77 Soil ratingz 100 ft2/bdrm Deep Trench (g.p.d./ft or ft2/bdrm) System type Length 43 ft. Width 3 ft. Gravel below pipe 7 ft. Total depth 11.5 ft. Eff. absorption area 602 ftz Monitoring tube Y Depression over field N Date'of adequacy test 5116/13 Results (Pass/Fail) PaSs For 6 bedrooms Fluid depth in absorption field before test 0 in. Water added 900 gal. New depth 0 in. Elapsed Time: 180 min. Final fluid depth 0 in. Absorption rate >= 900+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) None Known If yes, give date D. LIFT STATION Date installed "Pump on" level at Datum Size in gallons in. "Pump off' level at Cycles tested E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer /septic service line Animal containment areas SEPTIC/HOLDING TANK ON LOT TO: in. Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank Manure/animal excrete storage areas Building foundation 5'+ Property line 10'+ Water main 10'+ Water service line 10'+ Wells on adjacent lots 200'+ ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water Service line 10'+ Surface water 100'+ Curtain drain None Known Wells on adjacent lots 200'+ Absorption field 51+ Surface water 100'+ Water main 10'+ Driveway, parking/vehicle storage 10'+ in. F. COMMENTS The septic tank arrangement consists of two tanks, a 1000 gallon followed by a 750 gallon tank, both single compartment tanks. This was approved by the MOA on 10/17/77. FBUNc�t'(-oa Co ivs�fle iv�si�e res��e�t�e )a 5/21311z G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Paul E. Pinard; P.E. Date 5/20/13 COSA brown sheet 10.10-12.doc PINARD ENGINEERING P.O. Box 871347 Wasilla, AK 99687 (907) 357-ENGR (3647) ADEQUACY TEST LOCATION: Lot 108, Dawn Subdivision APPLICANT: Jessica Anderson 21706 Morning Drive Chugiak, Alaska 99567 SEPTIC TANK TYPE/SIZE: Steel/1000 + 750 Gallons, per MOA Records ABSORPTION SYSTEM: Deep Trench, per MOA Records DAILY FLOW: 6 BEDROOMS x 150 GAL/BR = 900 Gallons TEST DATA JOB NUMBER: 13-139 DATE OF TEST: 5/16/13 FIELD STAFF: PJ Pinard NUMBER OF BEDROOMS: 6 SCUM: 0.0' SLUDGE: Minimal NEEDS TO BE PUMPED: Yes No XX CURRENTLY IN USE: Yes XX No Time Flow Rate Volume Cumulative Volume Septic Tank Septic Tank Soil Absorption System Comments PM (GPM) (GALS) (GALS) Liquid Level ` A Level Monitor Tube 1* A SAS Level Monitor Tube 2* A SAS Level 1:35 5.0 4.0 0.0' StartFlow-Meter 55420 1:50 5.0 75 75 4.1' 0.1' 0.0' 0.0 55495 2:05 5.0 75 150 4.1' 0.0' 0.0' 0.0' 55570 2:20 5.0 75 225 4.1' 0.0' 0.0' 0.0' 55645 2:35 5.0 75 300 4.1' 0.0' 0.0' 0.0' 55720 3:05 5.0 150 450 4.1' 0.0' 0.0' 0.0 55870 3:35 5.0 150 600 4.1' 0.0' 0.0' 0.0 56020 405 5.0 150 750 4.1' 0.0' 0.0' 0.0' 56170 435 150 900 4.1' 0.0' 0.0' 0.0 Stop Test - 56320 Time *ALL MEASUREMENTS IN FT. TEST: PASSED XXX FAILED COMMENTS: Testing on this W WDS found it to be operating satisfactorily. There was no measurable liquid in the SAS MT prior to or at any time during the test. � ✓I Reviewed by: Paul Pinard "K A` Date: 5120113 i C-71 *17 -- I ---- (5-17,47 t -a:/3 AJ-t.i t AS-HUILT I hembv cendv that t have surveyed the fohawing described Fmpertp J r - Ancho�me Reeard� sctnei, Alaska, and that he improv mems situated themon are within theprnperty lows and do riot ntvrlap or encn,arh an the property lying adjacent therein, that nn improvements on pmgcrty tyin adjacent thartr+ CnlnJ3Ch on the premises in question and khat there am no roadways, nansmtsseon lines or other visible easements on said property except av indicated hereon flitted at Eagle Rimer, Alaska thisA71 �-`_dav of ROBERT C- JOHNSON SCA U: Registered Land St tnior 890-L9 7&ax 77-0955. Eagle Rhwr, Alaska 99577, le Phone (WM 69&2 13 t