Loading...
HomeMy WebLinkAboutBRUIN PARK BLK 5 LT 8Bruin Park Block 5 Lot 8 #016-111-38 rr - Municipality of Anchorage Nvpg4m On-Site Water and Wastewater Program • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: SW030448 PID Number: 016-11-38 Dwelling: 0 Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑ Upgrade Name: DEANNA BAKER ABSORPTION FIELD Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address❑ 11211 POLAR DRIVE ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 0.6 GPD/SF 71 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3 Ft.8 Gravel depth beneath pipe Ft. Subdivision Block Lot BRUIN PARK BILK 5 LOT 6 Fill added above original gradeGravel 0-1 Ft length 62,5 Ft Township Range Section Gravel width 2 Ft, Beds: Number of Lines NA Distance between lines NA Ft. SEPARATION DISTANCES To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Lift Station Tank Line 1000 Ft z 1 NA Ft. Well >100' >100' NA NA >25' TANK 0 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer ANCHORAGE Capacity 1250 Gal. Surface water >100' >100' NA NA Material STEEL Number of compartments 2 Lot Line >5 >10' NA NA NA Foundation >5' >10' NA NA LIFT STATIONManufacturer Capacity I I Gal. Curtain Drain >50' >50' 1 NA Remarks ASBUILT BASED UPON ONSITE INSPECTION Pump on level at in. Pump off level at in. High water alarm at in. 10-20-13 AND NOTES FIELD NOTE FROM TOBBEN SPURKLAND Pump make and model Electrical Inspections performed by PIPE MATERIAL Nouse to tank 3034 Tank to 3034 drainfield Installer MONTE ACHENSON Drainfield F810 CO/MT F810 Inspector TOBBEN SPURKLAND BENCH MARK (Assumed elevation)100 it Inspeection 1" 11/14/03 11/14/03 Location and description ction 2"" 3r° a" BOTTOM SIDING COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL � s ^< f�r"iN Il y Conditional Approval: Date �! c h -y Y� tt `�.j f i t % / 10 LA SPURiXLAIND 3'. 1 155c0 \\O\ L�`�nl�®� Approved Date l 3d IL{ Inspection Report 9- - 2.doc STANDARD TRENCH 62.5 FT LONG 11 FT DEEP 8 FT SEWER /VE GAL Sf TANK 8 ----- ¢Well 24 \ / ' . ♦♦1 NOTE TN1s 1s NOr uRvfrfO Pur. SLC a sEPr1c / . �P.. """ "" ^,• TIONS TAKEN fROM -S/If WA )ER AND WASTE .•, \ ♦♦♦ RTNENT DOCCMI£NT- .� ALL LOC SHO ARE / / i �. APP AUT£. '� 49th 10D ,,... ............ B / %-'� SPURKLAND 25 0 25 50 75 100�♦♦. No. cE-ii5oo.•ti,� �. \ SCALE' 1' = 50 FT /� / � ♦� �� / � � ♦��aaawwww��� TOBSEN SPURKLAND P.E. LOT 8 BLOCK 5 BRUIN PARK SEPTIC SYSTEM ASBUILT 103 W 15TH. AVENUE DEANNA BAKER DATE. OCT. 30, 2013 (NCH. AK. 99501 (907) 279-3916 POLAR DRIVE SHEET. 213 GRID: 2633 PERMIT #SV030448 PID # 016-11-38 BRU05082.DV5 0 M, Standard Trench., TEST HOLE EG. £L£V=91 Sil t 80H. £L£V=75.8' 2' Wide 625' Long 11' Deep 8,0' Sewer rock 1250 gal Septic tank o 8,0 ft of' Septic Rock Effective 1250 gal, septic tank ND SCALE 80H. £L£V=75.8' TOBBEN SPURKLAND P.E.SEPTIC SYSTEM ASBUILT 203 W15th Ave LOTBBLOCK 5 BRUIN PQRK Anchorage Ak 99501 DEANNA BAKER DATE, OCT. 30, 2013 �70_1014 POUR DRIVE SHEET, 3/3 GRID- 2633 PERMIT / SW0300XX PARCEL ID 1016-111-38 BRU05083.DWG --�— ~ Municipality of Anchorage O ;• T� M Department of Health and Human Services 825'L' Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Rick Mystrom httplhw a anchorage.sk.us Mayor Permit Number: #SW 030448 Date of Issue: 10.21-03 Parcel Identification Number: 016-111-38 Date Started: 1015-04 Date Completed: 10.22-04 Is well located at approved permit location? ® Yes ❑ No Legal Description: Bruin Park Blk 5 Lot 8 Property Owner Name & Address: Deanna Baker Pa Anchorage. Alaska 9950T- q 17M Borehole Data: Depth (ft) Method of Drilling ® air rotary ❑ cable tool Soil Type, Thickness & Water Strata -- From To Casing type: steel stick-up 0 2 Wall Thickness: .250 inches organics & sift 2 3 Diameter: 5 inches Depth: 234 feet silt 3 7 Liner Type: gravelly silt sandy silt gravelly sift 7 37 121 37 121 165 Diameter: inches Depth: feet Casing stickup above ground: 2 feet Static water level (from ground level): 89 feet Pumping level: 234 feet after sandy gravelly silt H2O 165 175 2 hours pumping 25 gpm gravelly silt 175 211 Recovery Rate: 25 gpm silt 211 228 Method of Testing: airlift Well Intake Opening Type: water sand & gravel 228 234 ® Open End ❑ Open Hole ❑ Screened Start feet Stopped feet ❑ Perforations Start feet Stopped feet Grout Type: bentonite granules Volume: I Depth: Start 0 feet Stopped ? feet Pump: Intake Depth - - feet - _ -- - —' — Pump size hp Brand Name Well Disinfected Upon Completion? ® Yes ❑ No Method of Disinfection: chlorine tablets Comments: Well Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and the property Alpine Drilling & Enter; prises INVOICE Domestic —Commercial ' Pump d Water Systems 5 010 P. O. Box 110496 me / ocaupn,y Anchorage. Alaska 99511 W 1 (907 345-0202 n n _ ► r k TO: III a c � I GC.• I Q IF v I OUARM LABOR Thank You DESCRIPTION 1A Co9l� Ll4 -.50 A., -I- 0- Give a copy of the enclosed well log to the MOA within 60 days. Keep a copy for your records. HOURS RATE AMOUNT TOTAL MATERIAL TOTAL LABOR AMOUNT StGNATDNE Q Hereby Achr ledge IAe Salisfeoory Completion of the Above Dash-- Work I TERAAS: ACCOUNTS PAYABLE AT 10TH OF MONTH FOLLOYVING SERVICE CHARGE AT RATE OF 15% PER MONTH IVILL BE CHARGED ON OVERDUESACCOUNTS. MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM ) WATER SUPPLY PERMIT Initial Permit Number: SW030448 Legal Description$Bruin Park Block S Lof 6 Design Engineer: 0007 Tobben Spurkland, PE Owner Name: Deanna Baker Owner Address: 10312 Ridge Park Drive Anchorage , AK 99507 - v3 -WOLt yfhl Date Issued: Oct 21, 2003 Expiration Date: Oct 20, 2004 Parcel ID: 016-111-38 Site Address: 11211 Polar Drive Lot Size: 20000 SO. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑Q Disposal Field ❑,/ Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: 10 Date: 3/G Date:2 O Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519.6650 www.ci.anchorage:ak.us (907) 343-7904 ON-SITE SEWERMELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 0 1 ({1— 1 � \ — -Z _ Permit Number SW03C448 Property owner(s) IJ EANNA B AtC61Z Day phone 3'i q - h 5'd to Mailing address (1) 10312 'ZID6E PNP -1L DR Mailing address (2) Zip Code Qq SO -7 Legal description (Lot, Block & Sub'd.) 1-0 i 81 'BY -5 3eL) i rj Patzlc gin Legal description (Section, Township & Range) I 1 ?_l � Po1 Lot Size ,0 I OOO AcreS49D THIS APPLICATION IS FOR: Number of Bedrooms H Sewer Only ❑ Well Only. ❑ Sewer and Well a Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above Information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authortzed; bgent) Permit Fees: 0 049 °= M Waiver Fees: II/JJDate of Payment: 10 / 9 /V;3 ate of Payment: Receipt Number: `I del Io % Receipt Number: (Rev. IV00) T.SPURKLAND P.E. 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907)279-3916 Fax (907)-2766013 SEPTIC SYSTEM DESIGN LOT 8 BLOCK 5 BRUIN PARK S/D 1013"X" :31.1 N:41 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street Anchorage, Alaska 99519-6650 October 9, 2003 We are submitting an application for the installation of a well and septic system for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the well and septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable test holes are also enclosed. The septic system design is based on the following: No Ground Water or Impervious Layer to 17 R Use Standard Trench Soil Rating. From Testhole 03/18/03 25 min/in a 0.6 gal per sq.ft/day No. of Bedrooms 4 Required Area per Bedroom: 15010.6 - 250 sq.ft. Total area required: 250 x 4 s 1000 sqft Testhole depth 17 feet Bottom Rock At 11 feet Top Rock At 3 feet Rock Depth 8 feet Minimum Trench Length 1000 / 16 - 62.5 ft. SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 62.5 FT TOTAL WIDTH 2 FT TOTAL DEPTH 11 FT ROCK DEPTH 8 FT COVER 3 FT SEPTIC TANK 1250 GAL The installation of this well and septic system will not prevent wells and septic systems from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. X 2/ \ /\ 20 \ v / 17 \ / \y Well \ 24 1Y \ /\ 9 23 ,4� \ / / 22 p��EOF ,b . ,�P...••.............. ♦i Cj 49th \ \21 i.......:.. ................... \ �� TDH N SPURKLAND ♦♦fir NO. CE -2223 •� 50 0 50 Ix 150 m ew 300 ♦♦j♦ , .V��� SCALEr 1' = 100 f7. ♦ En :� IMUM.N )FUKKI AIVU r r. I I LOT 8 BLOCK 5 BR(IIN PARK I I SEPTIC SYSTEM DESIGN A20JNC W 157H. AVENUE DEANNA BAKER DATE: APRIL 1 1003 ANCH. AK. T019 POLAR DRIVE SHEET. 1/3 GRID: 2633 /oml ��o_tofa IPERMIT 1I SV030XXX PID # XXX BRU05081.DV6�11 SV030XXX PID # XXX BRU05081.M / � G - Z� Well N�V !� mffDiie D vc k� SrMaaq 6ZS IT \ / / /1 iT o CdL TAMC `` • - 4' Well .. �%% left A?4 / th ` v .....: «...................: ♦ rm sruakCM,n' . 2s 0 25 50 75 jw 125 / +F \ SCAL£! 1' = 50 FT. / /� TOBBEN SPURKLAND P.E. LOT 8 BLOCK 5 BRUIN PARK SEPVC SYSTEM DESIGN 203 W 15TH. AVENUEDEANNA BAKER DATE.• APRIL 1 2003 (NCH. AK. 99501 907 279-3916 POLAR DRIVE SHEET.2/3 GRID: 2633 PERMIT USV030XXX PIB # XXX BRL105082DVG Standard Trench, 2' V/de 62.5' Long 11' Beep 8.0' Sewer rock 3' Cover IVO SCALE Sit t Bo 8.0 ft of Septic Rock Effective 0 0 N 0 tR 1250 gal Septic tank c 0 d 3 a Monitor ND SCALE 49th NEN SPURKLAND No. CE -2225 a 1250 gal. septic tank I , UnntN Z rUKKLANU r.L. I I LOTBBLOCK 5 BRUIN PQRK I I SEPTIC SYSTEM SCHEMATIC I 203 W15th Ave OfANNA BAKER DATE Anchorage Ak 99501 APRIL 1, 1003 F" DRAT SHEET, 3/3 GRIDS 2633 Paw / sW030oXX PARCEL ID / XX BRU05083.DW0 Depth 1 • �11 0R6ANrcSo Z- _ Municipality of Anchorage �, 3. Si�4y SauQ(/ G. Development Services Department �R c - Building Safety Division e• On -Site Water and Wastewater Program • o C i S 4700 South BraL P.O. Box 1966:0 Anchorage, AK 99519-6650 vwv+ ti ancherace ce aft us m C . (907) 343-7904 it Soils Log - Percolation Test 12- Per!onred For: D C Ac N NA 171AZV-T=- rL Dale Performed: LevalDescrptien: i 131Erj BtZVIN 510 Township, Range, Section: tC- Depth 1 • �11 0R6ANrcSo Z- _ ' 3. Si�4y SauQ(/ G. -.� S4H[i•� Se [-f c - e• 7. 10- . 11. 12- `;•• 13- tC- t 5 ... .7 eprro«r or No1_k r_ 2C •I CC•.....cNTS v:AS CROWD WATER E.`:CCC?No :TER?7? 'Y 5 IF YES. AT WHAT DEPTH? L 0 Depth to Water After P Monitoring? C t E Date: 3 �o HM 3pve11md Site Plan Reading Dare Gross Time I Rel Time I Depth to Water I NO! D•C^, Cir I_ 'i -/P •t 3I i�fiSO4�1 — I I :°C, I yJ7Ki I ° I o2 ° i ° r70 I �o .1 ° I � 3:20� 30 � `''�M� IE�ef_ FERCCLATICH PATE05_FERCY.CLSG=:.:ET-; TEST RUti 9E7,Area;I 5 _ F -i AND (� FT BY. /. 5 I i , 5 cE;T:FY THAT Tia T=s- • '•s PERFOR': ED IN ACCORDANCE WITH ALL STATE AND AtU.'1:CIPAL GUIDELINES IN EFFECT DH Tr.:S DATE. DATE: 3/8 o