Loading...
HomeMy WebLinkAboutROBINDALE #1 BLK 1 LT 1Robl*ndale #1 Block 1 Lot 1 #051-052-52 MOA has confirmed that the on-site systems have not been installed. N DZunicipality of Anchorage P.O. Da IW650 • Anchomgc. Alaska SY.I5194W • Tcicphunc ('.X)7) 343 -&'SOI • ran ('.X)7) 3434LUX) 4700 Drxgax• Slrca • Anchomgc. Muslut tY9507 War xuw.nnLorg Mgich Building Snfcty Dix9sior4 August 16, 2004 Greg Chandler 24020 Reese Road Chugiak, AK 99567 Subject: On -Site Water and/or Wastewater Permit. Permit Number: SW030308 Legal Description: Robindale 91 Block 1 Lot 1 Dear Mr. Chandler: An On -Site Water/Wastewater Permit, number S W030308, issued by this office for a single-family system, expired on August 12, 2004 This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. et If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit for a second year may be issued for a fee of $115.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are: $460.00 for a wastewater permit and $175.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincerely, Daniel J. Roth Program Manager On -Site Water and Wastewater Program Enc: Copy of permit Community, Security, Prosperity MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Renewal Permit Number: SW030308 Legal Description: dROBINDALE #1 BLK 1 LT 1' Date Issued: Aug 13, 2003 Expiration Date: Aug 12, 2004 Parcel ID: 051-052-52 Design Engineer: 0070 KND Engineering Site Address: 024124 REESE RD Owner Name: Greg Chandler Lot Size: 33503 SO. FT. Owner Address: 24020 REESE ROAD Total Bedrooms: 3 Permit Bedrooms: 3 CHUGIAK , AK 99567-5507 This permit is for the construction of. 0 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specked In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: Date: 3 03 Municipality of Anchorage Development Services Department Building Safety Division / On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchcrage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. (� — 0 S2 — .r2 Permit Number SW 030308 Property owner(s) 6m'/ L4 Day phone �rn ��'� r Mailing address (1) c>�40,')L e) Jz� J�r '110 V-%-(o)I b k DVS Sin" 2u1 Zl4 Q� C S( V (! Zip Code -AAa+irftgaddress (2) Legal description (Lot, Block & Sub'd.) 47 r --b 6 k rlc (.c / Legal description (Section, Township & Range) l5 6 4 L Lot Size 3 3, .ro 3 Acres/Sq.Ft. Number of Bedrooms 3 THIS APPLICATION IS FOR: Sewer Only ❑ Well Only ❑ Sewer and Well Q Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Faml welling and is in accordan it j plicable Municipal Codes. of or authorized agent) Permit Fees: J10D 9 e, r? e &/& I Waiver Fees: Date of Payment: 5? - 9 ` O 3 Date of Payment: Receipt Number: 39 S !/q U " Receipt Number: (Rev. 12/00) Municipality of Anchorage m ae ,• •, Mark J3eJich. Mayor Bttildinaf Safety Division P.O. Box 196050 • 4700 Dragaw Street Anchorage, Alaska 99519-6650 • (907) 343.8:301 • Pax (907) 343.8200 hull/mm.mmd.org July 25, 2003 Greg Chandler 24020 Reese Road Chugiak, AK 99567-5507 Subject: On -Site Water and/or Wastewater Permit. Permit Number: SW020280 Legal DescriptionMobirfdale #1 Block 1 Lot 1 T Dear Greg Chandler: An On -Site Water/Wastewater Permit, number SW020280, issued by this office for a single-family system, will expire on August 8, 2003. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit for a second year may be issued for a fee of $100.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are: $400.00 for a wastewater permit and 5150.00 for a well permit. If you have any questions, please call this office at 343-7904. S' e -ly, 1 ames Cross, P.E. Manager On -Site Water and Wastewater Program Enc: Copy of permit MUNICIPALITY OFANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number: SW020280 Legal Description: ROBINDALE #1 BLK 1 LT 1 Date Issued: Aug 08, 2002 Expiration Date: Aug 08, 2003 Parcel ID: 051-052-52 Design Engineer: 0070 KND Engineering Site Address: 024124 REESE RD Owner Name: Greg Chandler . Lot Size: 33503 SO. FT. Owner Address: 24020 REESE ROAD Total Bedrooms: 3 Permit Bedrooms: 3 CHUGIAK , AK 99567-5507 This permit is for the construction of: �j Disposal Field ❑✓ Septic Tank ❑ Holding Tank F] Privy Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: _S— 0 'r/; Z Date: R -!a - o Z Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWERIWELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel LD051-052-52 Permit Number SW [7 2 d 2'90 Property owner(s) Greg Chandler Mailing address (1) 24020 Reese Rd., Chuglak, DayphoneA88-2935 AK 99567 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd) Robindale No -1, Lot 1, Block 1 Legal description (Section, Township & Range) Lot Size 33503 Acres/Sq.Ft. Number ofBedrooms,e� c%A Z o� z THIS APPLICATION IS FOR: Sewer Only ❑ Well Only Sewer and Well ® Water Storage Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi Swimming Pool ❑ Water Softening Unit EJ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: 0 03 -1, Receipt Number: (Rev. MOO) Waiver Fees: Date of Payment: Receipt Number: ITID ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER. AK 99577-8 (907)696-6111/FAX (907)696-8111 July 2, 2002 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: New sewer/well permit — Robindale No.1 Lot 1, Block 1 Gentlemen: The owner has requested we proceed forward to obtain a septic/well permit on the subject lot. On May 14, 2002 one testhole for the proposed system was excavated. The results of this test are attached. The general slope of this lot is flat. We have designed our system utilizing the existing testhole that was excavated for the 2 -bedroom existing house. The lot will be served by an individual well, located on the northeastern portion of the lot. We propose to install two 5' wide shallow trench. Seasonal seeps were encountered during excavation between 3' - 5.5' but no water was present during monitoring. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, MUD Engineering, Inc. Kenneth M. Duffus, P.E. Attachments: On -Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test WELL & WASTEWATER DISPOSAL SYSTEM DETAILS/SITE PLA R❑BINDALE S/D, NO, 1, LOT 1, BLOCK 1 REESE ROAD io& 13'M I 1 A /1 „ . • . I I LOP 1 LOT 2 ❑CK 2 LOT 3 NO PUBLIC YELLS WITHIN EV R PBCPOSE3 SYSTEK W PMIVATE WELLS Wt" Baa 6 PRUPU= SYSTEM EXCEPT AS NNM In SEPTIC SYSTEM VIYHIM 2W 3F PR POSCD WELL EXCEPT AS M3TED. IF /* 9TH *� I Ij 0 O O I� ILOT 2 Z 10 w I Iz cn 1 0 BLOCK 1 II �I 1 LOT 3 d' I -I DESIGN DETAILS 2 BDRM X 150 GPD = 300 GPD 300 GPD/.6 GPD PER SO. FT. (13.7 MIN/IN.)= 500 SQ. FT (500/5'(W)) X .88(RF) (1.0' GRAVEL) = 88 FT. TRENCH USE 2 TRENCHES - 44 (L) X 5' (W) X 1.0'(D) Total depth of system Is 4.0' from orlglnal grade. Total depth of gravel below distrlbutlon plpe Is 1.0' . r Ray. L NOTES, 1. USE 1000 GAL SEPTIC TANK, INSULATE IF (4' OF COVER. 2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM, IF (3' OF COVER. 3. CONTRACTOR VILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK. 4. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN. 3' COVER IF REQUIRED. 5. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS, SEPTICS, LOT LINES, FOUNDATIONS AND ALL OTHER SETBACKS. PREPARED FOR, GREG CHANDLER 24020 REESE RD. CHUGIAK, AK. 99567 (907) 688-2935 * - I FIELD BOOKS CS -7118 �� j eaia�wr: srAXBMR A�IXLr. OM FSC ACRO ESE nnn , COMPUTER ORARK VBG au'XE'X KMD DANEDA'L 7/10/ am NW156 roe M" 02027 Scale, 1'= 100' PAGE 1 OF 2 ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 1 WASTEWATER DISPOSAL SYSTEM DETAILS R❑BINDALE S/D, NO. 1, LOT 1, BLOCK 1 0 PROF u Oi•t im ww :f ///////////////////////I *--49 :. ....... ... .... ..... .D S• / +1, CE -7116 �93IOtt�' - 8' r-13' 0-5% LOT PREPARED F❑Ri GREG CHANDLER 24020 REESE RD. CHUGIAK, AK. 99567 (907) 688-2935 FIELD BOOKS eaiwrnr: n�a wear. rat nm peen FLM ,.nmn , to z 0 z CompuTm VBG 00"lk KMO oes 7/10/ NW156 J'a w- 02027 1 11" Util Esmt 05E® Oli=1. ---- ' ®Till ('_R ,®POSD 1000 1 TAN 34' FCC iEXISMNG 2 Scaler 1'= 20' PAGE 2 OF 2 ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 1 KNID ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 SOILS PERCOLATION TEST Performed for. Greg Chandler Date Performed: 5/14/02 Project: Robindale #1 Bl. Ll TEST HOLE # 02-1 1- 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- Depth (Feet) Org/—brown, moist overburden w/organics Seeps SM/GM — med dense gray w/cobbles to 6 B.O.11. HOLE PRESOAKED PRIOR TO TEST SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Groundwater encountered? YES What depth? 3.0-5.5 (seasonal seeps) Depth to water after monitoring? NO Date? 5/21/02 Reading Date Gross Time Net Time Depth to Water Net Drop 1 5/21/02 1:00 - 6" - 2 1:30 30 min 3 11/16' 2 5/16' 3 1:31 - 6" - 4 2:01 30 min 313/16' 2 3/16' 5 ' 2:02 6" 6 2:32 30 min 313/16' 2 3/16' • Water Added Percolation Rate 13.7 (min/ in) Perc Hole Diameter 6" Test Run Between 2.5 feet and 3.5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. Municipality of Anchorage • Development Services Department Building Safety Division % On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWERMELL SUBMITTAL COMMENT SHEET TO: KND ENGINEERING Legal description: ROBINDALE SUBDIVISION NUMBER 1 BLOCK 1 LOT 1 The attached paperwork has been reviewed and Is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. ❑ Additional soils information needed. ❑ Water monitoring results inadequate. ® Discrepancy in information submitted. APPLICATION REQUESTS 3 BEDROOMS & HOUSE IS LABELED AT 2 BEDROOMS & DESIGN IS FOR 1 BEDROOM ❑ Topographic information missing or inadequate. ❑ Incomplete; missing ❑ Incomplete; missing ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils information submitted. ❑ Well log required. ❑ Omission in narrative. ❑ Insufficient fill over tank or field. ® Other. SHOULD OUR OFFICE HAVE A FILE ON THE ONE BEDROOM SYSTEM?? Name of reviewer: DAN Date: 7/8/02 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK