MOA has confirmed that the onsite systems
have not been installed.
May 26, 2004
Alunieipaliiy Of Anchorage
,dark L'eyich, Mayor
Builditl(i Safety Dixisimi
P.O. Box 19W)50 • 4700 Bragau- Strect
Anchorage, Alaska 099519-GG50 • (907) 343.8301• Pax (907) 343.8200
hdp://u�w.niuni.org
Jeremy Root
8528 Emerald Street
Anchorage, AK 99502
Subject: On -Site Water and/or Wastewater Permit.
Permit Number:SW030168 _
Legal DescriptionET12N.UW Sec,10 Loi 18 South 1/2'
Dear Mr. Root:
An On -Site Water/Wastewater Permit, number SW030168, issued by this office for a single-family
system, will expire on June 3, 2004 This permit was valid for 365 calendar days.
If this .vas a well permit and the well has been drilled, a well log must be sent to this office for
documentation of the installation and to close the permit.
If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to
this office for review, approval and documentation. This as -built inspection report must be signed by
the licensed Professional Engineer who inspected the installation of the system. As -built inspection
reports are required to be submitted within 30 days of the completion of the system.
If no system was installed under this permit, and you are still planning to install a well or wastewater
disposal system, a new permit must be obtained from this office. A new permit for a second year may
be issued for a fee of $115.00 if the renewal application is received on or before the expiration date of
the original permit.
When applying for a new permit, the fees are: $460.00 for a wastewater permit and $175.00 for a well
permit.
If you have any questions, please call this office at 343-7904.
Sincerely,
(✓ `--;
Daniel Roth
Program Manager
On -Site Water and Wastewater Program
Enc: Copy of permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water& Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ONSITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Initial
Permit Number: SW030168
Date Issued: Jun 04, 2003
Expiration Date: Jun 03, 2004
Parcel ID: 011-161-18
Legal Description: T12N R3W SECTION 10 LOT 18 SOUTH 1/2
Design Engineer. 0014 Anderson Engineering Site Address: 8528 EMERALD STREET
Owner Name: JEREMY ROOT Lot Size: 43768 SQ. FT.
Owner Address: 8528 EMERALD STREET Total Bedrooms: 4 Permit Bedrooms: 4
ANCHORAGE. AK 99502 -
This permit is for the construction of.
0 Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy
All construction must be in accordance with:
1. The attached approved design.
0 Private Well ❑ Water Storage
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either. A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
Date: 1
Date: G L4 03
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 0 / / - /6 -18 Permit Number S U 0 /68
Property owner(s),JeremyRoot Day phone 2432528
Mailing address(1)2910-Concord-Lane--Anchorage-AK-99502
SITE
Yutaitinefaddress (2)8528 E�%fRgL 0-:irmrer Zip Code /9502
Legal description (Lot, Block & Sub'd.)-5outh-1/2J3LM-LotJb-5ectionJO.112N-K4W
Legal description (Section, Township & Range)
Lot Size,.2611cre5 _ Acre q.Ft. Number of Bedrooms Jour. -(4
43, 768
THIS APPLICATION IS FOR:
Sewer Only ❑ Well Only ❑
Sewer and Well ® Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
Cf
(Signature of property owner or authorized agent)
00
Permit Fees: ,ASO Z� Waiver Fees:
Date of Payment: U 12'i I(iS Date of Payment:
Receipt Number: a gin f i Receipt Number:
(Rev.12100)
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522.7773 522.6779 (FAX)
May 27, 2003
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: South %: Lot 18, Section 10, T12N, R4W
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of the South''/: of Lot 18, Section 10, T1 2N, R4W intends to construct a new
four-bedroom home on the lot. We are therefore requesting a permit be issued for the
construction of a new well and septic system to serve the home. The attached Site Plan
and backup documentation identify the location and configuration of the new septic
system and alternate site and the parameters used in the design. Also identified on the
plans are the location of the proposed well, test holes and the wells and septic systems
on the surrounding lots. Drainage arrows and spot elevations are shown indicating the
current drainage patterns. The drainage patterns will be maintained after construction.
The test holes placed near the location of the proposed absorption trench and alternate
site indicated clean sand with some gravel and varying amounts of silt and percolation
rates approximating 2 to 5 minutes per inch. No ground water was found during
placement of the test holes and none was noted during the monitoring period. We are
therefore proposing to place a 1,250 -gallon septic tank and a 35' long x 3' wide x 8'
effective depth absorption trench. The distribution pipe will be placed 2' below the
existing surface and the total depth will be 10'. Sufficient fill will be placed over the
septic tank and absorption trench to prevent freezing.
The ground surface on the lot slopes as shown on the site plan from west to east at
varying slopes. The absorption trench will be constructed at the front of the lot parallel
with the slope as much as possible in conformance with Municipal requirements. All
components of the new septic system will be constructed a minimum of 100' from any
surface water and 100' from the well on this and adjacent lots.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future. The subdivision is currently
South % Lot 18, Section 10. T12N, R4W
May 27, 2003
Page Two
served by the Municipal water system.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Eat" �
r
Michael E. Anderson, P.E.
Attachments
_
M-CNaEE E. ANDERSON
11 No. CC -438 i
C� Co
R 3 8
A P7502 g 2 y
�y
132.65N N 174 95
297.10 295.05 Cane
889)41'10-E 371.05 61277
O
• J
R R Q
ffi W
" W
296. -- m....,.
s
.Vacant Lot
ID
'D I296.,9 cem9
CO EIGHTY SIXTHAvenu
i
y 296.19 Cane 298.12 Camp
R
� p R
831.17
1g
a
� e
AREA MAP ''/�P�� °F.'."" "•.a
—i "~
1. 1�.f 49th
SCALE `'s•
lags
.�;Lwcwt¢E.u+oErasoN ��=
. SOUTH 1/2 LOT 18, SECTION 10, T1 2N, R4W
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom Home Deep Trench System
Perc. Rate: 4 MinJlnch 1,250 Gallon Septic Tank
Application Rate: 1.2 GPD/SF 8' Drainfield Rock
4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area
500 SF/16 SF/LF = 31.25 LF Trench Length
THEREFORE: Construct a 35' Long x 3' Wide x 8' Effective Depth Absorption Trench.
Flow Line Elevation in Trench to be 2' Below Original Ground Surface. Total Depth to be
10' Below Existing Ground. Maintain 100' Separation From Well on Lot. Place 2' of Direct
Bury Insulation and 2' of Fill Over Absorption Trench or Provide Minimum 3' of Cover to
Prevent Freezing. 4' of Cover Over Septic Tank.
Natural
Backfill
Geotextile
Fabric
6' 4" Perforated
PVC (Holes Down)
8'0" 1 1 �Drainfield Rock
3
F ' i
TYPICAL DEEP TRENCH SECTION
(NO SCALE)
NOTE: Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater.
Minimum 1 00'Separation From Wells in the Area.
Minimum 100' Separation From Surface Water or Streams.
2
3
4
5
6
7
8
9
K
11
17
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENVON-SITE WATER AND WASTEWATER PROGRAM
4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
PROJECT #:
PERFORMED FOR: Kevin Monaghan DATE PERFORMED: - 5/16/2003
LEGAL DESCRIPTION: South 1/2 Lot 18, Section 10, T12N. R4W
�T"TT TEST HOLE # 1 SLOPE
I I I I II PT/OG
Silty sand
Some Gravel - SW
9 a % 49th
No.
BOH - 18'
2%
WAS GROUNDWATER
ENCOUNTERED? No
IF YES, WHAT DEPTH?
DEPTH OF WATER None
AFTER MONITORING:
,.._ DATE: 5/26/2003
S
L
0
P
E
SITE PLAN
I 3
I/ THIO °
m'
0
TH2
® N
A
Is.
READING DATE
GROSS
TIME
NET
TIME
DEPTH OF
WATER
NET
DROP
Start 5/16
11:10
10.63"
1
1120
10
0
10 63"
Recharge
1121
10.5"
2
11:31
10
0"
105,
Recharge
11:32
10.5"
3
1142
10
0"
1 q -
PERI: RATE: I_ MIN./INCH PERC. HOLE DIAMETER:
TEST RUN BETWEEN--L5--FT. AND SS T.
COMMENTS: Test Hale Pre Soaked Prior to Test.
TEST PERFORMED BY: MEA I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 5/26/1003
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT/ON-SITE WATER AND WASTEWATER PROGRAM
4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST
PROJECT #:
PERFORMED FOR: Kevin Monaghan DATE PERFORMED: 5/16/2003
LEGAL DESCRIPTION: South 1/2 lot 18. Section 10, T12N, Row
TEST HOLE # 2
PT/OG
8
9
K
11
17
Silly Sand
Some Gravel - SW
SLOPE
2%
WAS GROUNDWATER
ENCOUNTERED? No
IF YES, WHAT DEPTH?
DEPTH OF WATER None
AFTER MONITORING:
k..- DATE: 5/26/2003
No. [[.a M,
S
L
0
P
E
SITE PLAN
Is..
READING DATE
GROSS
TIME
NET
TIME
DEPTH OF
WATER
NET
DROP
Start 5/16
11:15
9.75-
1
1125
10
0
9 7S"
Recharge
11.26
9.5"
2
1136
10
0"
9 S'
Recharge
f 11:37
1
1 9.75'
3
11:47
10
0"
9 75'
PERC RATE: _1 MIN./INCH PERC. HOLE DIAMETER: 6"
TEST RUN BETWEEN--AJ—FT. AND 5.5 T.
COMMENTS: Test Hole Pre Soaked Prior to Test. Identical Soils Conditions as THt.
TEST PERFORMED BY: MEA I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 5/26/2003
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: SOUTH % LOT 18, SECTION 10, T12N, R4W
GENERAL:
1. The scope of this project includes the procurement and placement of a
new 1,250 -gallon tank at the location shown on the site plan. Work
also includes the construction of a new absorption trench 35' long by 3'
wide by 8' effective depth also at the location shown on the Site Plan.
The total depth of the trench will be 10' below existing ground and the
distribution pipe will be placed at 2' below the surface. All components
of the new absorption trench and septic tank must be constructed a
minimum of 100' from any surface water and 100' from wells on this
and adjacent lots. A minimum of 4' of cover is required over the septic
tank and 3' over the absorption trench. In lieu of cover 2" of direct
bury insulation and 2' of cover may be placed.
2. Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
4. Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
A new 1,250 -gallon septic tank must be procured from a certified
septic tank manufacturer if the existing tank is found to be defective.
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
South 1/2 Lot 18, Section 10, T12N, R4W
May 27, 2003
Page 2 of 3
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfieid are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
6. Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
South % Lot 18, Section 10, T12N, R4W
May 27, 2003
Page 3 of 3
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as -built of the completed system.