Loading...
HomeMy WebLinkAboutTHE TABLELANDS BLK 6 LT 7The Tablelands Block 6 Lot 7 #051-801-30 Municipality of Anchorage Page 1 of 3 Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ok.us (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW040485 PID Number: 051.801.30 N'nnell Homes Inc. S i Wastewater System: New Acdress: 1900 W. Northern Lts. Blvd., Ste. 200 Anch., AK 99517 ABSORPTION FIELD pnoI e: ""°e as°°°""': Raised Bed 344.5678 Five 5 Sa Raanp: Tool Deem Dart ananal yraae: LEGAL DESCRIPTION .3 GPDXe 0 FI. ebek: La: Sebch l : Deco to ppe Donau apo o gnat pace: Gravel oaten Denealh P": The Tablelands +2 Ft. .5 Ft. 7ownsmp: Range: Secwn: Fm added aopva ag.nai pace: Grav Lergn: 3-6 Ft. 170 Ft. Well: AWWU Water System Gravel w M: 15 re. Nanw M t 6 Dwance aMaen knas: 5 Ft. FI. Ct&W"an (Pnwle. A e. Cl: TMN Depth: Cased W: Taal aeaapttn arse. P.Pe Mat": Ft. Fe. 2,550 Fe ASTM 3034 PVC DrMlx Date Dnaeo: SISIK water Laws: namwr. Dale Weald. FI. Pisano's Dirtworks 618.9/2005 Ytt: PWnp set at: I Caanp MAD Grand: TANK GPM FI. FI SEPARATION DISTANCES STEP To Septic Absorption LIR Holding blidPnvale ectWer' P ly0 Ga;w s. From Tank Field Station Tank SewerLiro Anchorage Tank 2,000 we >200' >200' >200' NIA >25' Mat". Steel Noon aGantanmenm: Three (3) sedaawaler >100' >100' >100' NIA LIFT STATION LMLIne >5' >10, >10, NIA We. 250 Gr a IWN. AnchorageTanklOrenco >5' >1 O' >5' N/A -Plant ai tenet at. 'Pump of Isvel at. HQh water atrm at.. FaaMettn 42 In. 42 n. 44 In. None Noted Pump Make &Motel Eranosi nepectd peramec DY �AenD*^ Orenco Allied Alaska Electric Remark" BENCH MARK insulation over Lntire Septic System. LMalgn Mt Dee" tltn: Finished Floor. Aawmed Etvanen: �.: 100.0 F1. Engineer's Stamp + 49th Inspections performed by: MEA Dates: k1"e 61812005 %_ ._ A.: / 3/ 2 n 619/2005 MICHAEL E ANDERSON ' W Department of fiealth and Human Services approval No. CE -4381 1.0 ♦ Reviewed and approved by: Date: LDhLe hye wed ;s;; .••� o - � a I \\\ 3aF S/yM Z I N O \�1�yS3 3 > 0 m Y 0 oq N 0 o C) m ci z b tLn.a% z4 1n w w J 4� 00, m LTJ —j4i oo¢ o m J o cn 5; =0 u— _ U) cw dp �0 �� i �j.pq w Lo °i d " ham• J o p L) 'gyp. \\ nii9i3 a •( \ .. i t i rc �• zo o fig! ••�6'' P Z ��� sr •••ls •... _ ,. Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519.6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit No. SW040485 TBM = S! PID No. 051-801-30 2' EPS Insulation S.T. E.P. 6 - 3/16' Holes Per Lateral 13' Spacing f v S MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 DEPTII (r«q SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: Lot /, block 6, the lablelands PERFORMED FOR, Spinell Homes DATE: 6/8/2005 PROJECT No- PARCEL o'PARCEL IDS TECHNICIAN: T. Kimbrough TEST HOLE # 3 ORGANICS/OB SLOPE 2 3 Silty Gravel with Sand 4 SM W1 6 BOH 7 8 9 See Site Plan 10 WAS GROUND WATER ENCOUNTERED? Yes IF YES@ WHAT DEM I? 4' 0% I 1 DEPTII OF WATER AFTER MONITORING: DATE OF MONITORING: 13 14 15 16 17 18 19 DATE READING G OSS TIME MINUTES) NET TIME (MINUTES) DEPTH of WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: PERCOLATION RATE;,_(Io"IINCI I) PERC. HOLE DIA, INCHES) TEST RUN BETWEEN: FT, and FT. COMMENTS: SAME MATERIAL AS TEST HOLE NOS. I AND 2. PERCOLATION RATE BETWEEN 30 AND 60 MINUTES PER INCH. TEST PERFORMED BY ANDERSON ENGINEERING SOILS TECHNICIAN. 1, MICHAEL E. ANDERSON CERTIFY TIIAT THIS WAS PERFOR\IED IN ACCORDANCE WITII ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: fW Jun 15 OS 10:36a Allied Alaska Electric (907) 373-3894 p.1 �l495�r��.Gr OIVRA GT/NG June 15, 2005 FAX: (907) 522-6779 Anderson Engineering Attn: Mike Anderson P.O. Box 240773 Anchorage, AK 99524 Subject: Lift Station Inspections at properties stated below. This letter is to confirm that the lift stations at: • Lot 6, Block 6 - Tablelands • Lot 7, Block 6 - Tablelands • Lot 10, Block 6- Tablelands • Lot 6, Block 2 - Glennview North were wired by a licensed Journeyman Electrician in accordance with the 2002 National Electric Code requirements. If you would like any further information, please feel free to call our office at the numbers listed below. Thank you. Sincerely, ALLIED ALASKA ELECTRIC, L.L.C. Janette L. Brown, Vice Presidcnt/CFO cc: file P.O. Box 876310, Wasilla, Alaska 99687 (907) 373-3893 ofc / (907)132-8687 cell / (907) 373-3894 jar ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Nov 23, 2004 Expiration Date: Nov 23, 2005 Permit Number: SWO40485 Parcel ID: 051-801-30 Legal Description: THE TABLELANDS SUBDIVISION BLOCK 6 LOT 7 Design Engineer: 0014 Anderson Engineering Owner Name: SPINELL HOMES, INC Owner Address: 23129 WHISPERING BIRCH DRIVE CHUGIAK . AK 99567 - Site Address: 23129 WHISPERING BIRCH DRIVE Lot Size: 41562 SO. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit Is for the construction of: ❑✓ Disposal Field ❑? Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and dosed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. a.) Depth of absorption trenches shall not exceed 6 feet below original grade. b.) Groundwater monitoring shall be conducted through construction. Results shall be Included with Inspection Report. Received By: Issued By. Date: //-Z320 5/ Date: MUNICIPALITY OFA DevelopmentServices Department � On -Site Water d Wastewater Program r Alb 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Nov 23, 2004 Expiration Date: Nov 23, 2005 Permit Number: SWO40485 Parcel ID: 051-801-30 Legal Description: THE TABLELANDS SUBDIVISION BLOCK 6 LOT 7 Design Engineer: 0014 Anderson Engineering Owner Name: SPINELL HOMES, INC Owner Address: 23129 WHISPERING BIRCH DRIVE CHUGIAK . AK 99567 - Site Address: 23129 WHISPERING BIRCH DRIVE Lot Size: 41562 SO. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit Is for the construction of: ❑✓ Disposal Field ❑? Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 (24 hours). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and dosed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. a.) Depth of absorption trenches shall not exceed 6 feet below original grade. b.) Groundwater monitoring shall be conducted through construction. Results shall be Included with Inspection Report. Received By: Issued By. Date: //-Z320 5/ Date: Municipality of Anchorage Development Services Department Building Safety Division _ On -Site Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. b,51—%6V 30 Permit Number SW Property owners) Spineil Homes, Inc. Day phone 3445678 Mailing address (1)1900 W. Northern Lights, Suite 200 Anchorage, AK 99517 Mailing address (2)x31 71 Whispering Birch Drive Zip Code Legal description (Lot, Block & Sub'd.) Lot 7. Block 6. Tablelands Subdivision Legal description (Section, Township & Range) Lot Size 41.562 SF Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms Five (5) Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: 4 en Waiver Fees: Date of Payment 1 I.1 ri +rj'i Date of Payment Receipt Number. d Receipt Number. (Rev. 12=) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX June 7, 2005 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 7, Block 6, The Tablelands Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Permit Number SW040485 Dear Onsite Services Engineer: The groundwater at Lot 7, Block 6, The Tablelands Subdivision has unexpectedly risen and is currently encroaching into the recently constructed absorption trenches. We therefore propose to replace the existing 1,500 -gallon septic tank with a 2,000 -gallon STEP Tank and replace the 5' wide absorption trenches with 2 new 84' long by 15' wide absorption beds. The bottom of the beds will be 1.5' above the existing ground surface, which is approximately 6' above the apparent water table at this time. The existing septic system construction permit issued for this lot does not expire until November 23, 2005. We are proposing to complete this work under this permit and will provide a certified as -built once the work is complete. Test holes recently placed on the lot indicated silty gravel with minor amounts of sand in the area of the absorption trench and alternate site. The accepting soils were tested and found to have a percolation rate of between 30 minutes per inch and 60 minutes per inch. The system is designed with an application rate of .3 GPD/SF. A minimum of 3' of cover will be placed atop the beds and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot has no slope from east to west as shown on the Site Plan. The absorption beds will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any Lot 7, Block 6, The Tablelands Subdivision June 6, 2005 Page Two surface water in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, ,-,t L 0,4, Michael E. Anderson, P.E. Attachments f 49th A U7CNAEL E. ANDERSON Existing Ground LOT 7, BLOCK 6, THE TABLELANDS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: 5 Bedroom Home Perc. Rate: 30-60 Min./Inch Application Rate: .3 GPD/SF Raised Bed System 2,000 Gallon STEP Tank Coarse Sand (As Required) 5 Bedrooms X 150 GPD/.3 GPD/SF = 2,500 SF Absorption Area 2,500 SF/15 SF (Width) = 166.7 LF Bed Length THEREFORE: Construct 2 - 84' Long x 15' Wide Raised Beds as Shown Below. Place Distribution Piping at 2' Above Original Ground Surface. Remove Organics and Place Coarse Sand to Provide 4' Separation From Groundwater (Minimum). Place Insulation and 2' of Cover Over Bed or Mound Over Bed Minimum of 3'. Place 4' of Fill Over Tank. .5' .5' 1.5' or As Required Top 6' of Mound Must Be Topsoiled and Vegetated to Prevent Erosion. Natural Backfill 2' Insulation 8 2' Cover (Min.) O O O Drainfield Rock Coarse Sand (See Specification) As Required for Levelling In Situ GM Soil 2.5' 5' 5' 2.5' TYPICAL BED SECTION 1' PVC (NO SCALE) =� NOTE: Grade Area Surrounding Bed to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 200' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. Minimum 10' Separation From Water Service Line. #*-, Existing Michael E. Anderson PRESSURE DISTRIBUTION CALCULATION Elevation at Highest Discharge Point Pressure at Highest Discharge Point Liquid Level in Tank (Elevation) Diameter of Holes in Distribution Line Diameter of Distribution Line Hole Spacing in Distribution Line Length of Transport Line Diameter of Transport Line Q=12.4dw = 12.4(.1875)(.1875) Y5- =..9748 GPM/Orifice _ .9748' 32 = 31.2 GPM TDH = (100.88) + .0192(31.2)(31.2) + 12' 31.9' + 18.7' .000995(45) (31.2) (1.5) -f- 87 + 1.2' 95' 5' Head 88' .1875" (3/16") 1.0" 13' 15' 1.5" Therefore 32 Orifices @ 13' Spacing With 31.9' of Total Dynamic Head. 6 Holes Per Lateral ONSITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 7, BLOCK 6, THE TABLELANDS SUBDIVISION GENERAL: The scope of this project includes the removal of the existing 1,500 - gallon septic tank and the procurement and placement of a new 2,000 gallon STEP Tank at the location shown on the site plan. Work also includes the removal of the existing piping from the existing absorption trenches and the replacement with clean coarse sand to the existing ground surface. Work will then include the construction of 2 new 84' long by 15' wide absorption beds also shown on the Site Plan. The distribution pipe for the beds will be placed 1.5' above the surface. Sand will be required to level the existing ground surface to provide a level plain for the new beds. All components of the new absorption beds, existing septic tank and lift station must be constructed a minimum of 200' from wells in the area and 100' from any surface water. Insulation will be required atop the trench to prevent freezing. In lieu of insulation a minimum of 3' of cover must be placed atop the trench. A minimum of 4' of cover is required over the Lift Station. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Contractor is also responsible to verify the separation distance from the well on this and adjacent lots. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK/LIFT STATION INSTALLATION 1. The 2,000 -gallon combination septic tank and lift station must be constructed by a certified tank manufacturer. Construction shall include an 18" manhole to provide access to the lift station. Lot 7, Block 6, The Tablelands June 7, 2005 Page 2 of 4 2. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 4. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 5. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drain field. 6. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAIN FIELD CONSTRUCTION: The drain field shall be constructed to the dimensions shown on the design. The bottom of the bed shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drain field rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drain field rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drain field are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drain field rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 7, Block 6, June 7, 2005 Page 3 of 4 The Tablelands MATERIAL SPECIFICATIONS: The lift station must be constructed by a municipally approved septic tank manufacturer. An Orenco 20 OSI 05 HHF-5 pump is recommended. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. FILTER SAND SPECIFICATION: 1. Material for Filter Sand must be classified as a masonry sand and meet the following gradation: 50% or More Passing the No. 4 Sieve 2% or Less Passing the No. 100 Sieve 1% or Less Passing the No. 200 Sieve INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Lot 7, Block 6, The Tablelands June 7, 2005 Page 4 of 4 Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX MEMORANDUM DATE: November 18, 2004 TO: Julie Makela, P.E. FROM: Mike Anderson, P.E. SUBJECT: Lot 7, Block 6, Tablelands Subdivision Septic System Construction Permit Although we feel Lot 7, Block 1, Glenn View Estates North Subdivision is one of the few in this area without groundwater problems we have modified the design in accordance with our previous conversation. The bottom of the absorption trenches has been raised to 6' below the surface. We are now proposing 5' wide trenches with an effective depth of 4'. The attached revised sheets are submitted for inclusion with the original design and permit application. Please let me know if you have further questions or comments. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX November 5, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 7, Block 6, Tablelands Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 7, Block 6, Tablelands Subdivision intends to construct a new five - bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is currently served by a community water system. No conflicts exist with adjacent septic systems or wells and the proposed septic system on this lot. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The current drainage pattern is identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Test holes recently placed on the lot indicated silty sand and gravel in the area of the absorption trenches. The accepting soils were tested and found to have a percolation rate of 17 to 60 minutes per inch. The system is designed for the slower percolation rate. No groundwater was found in either test hole during placement and none was found during the monitoring period, which included the wettest period of the year. Our design includes the placement of a new 1,500 -gallon septic tank along with 2 - 84' long by 5' wide by 4' effective depth absorption trenches to collect and treat the sewage generated in the house. The bottom of the trench will be 6' below the surface. The distribution pipe will be 2' below the surface. A flow splitter valve will be placed to assure even flow to each trench. A minimum of 3' of cover will be placed atop the trenches and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at shallow grades from east to west as shown on the Site Plan. The absorption trenches will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The Lot 7, Block 6, Tablelands Subdivision November 5, 2004 Page Two new septic system will be constructed a minimum of 10' from the water service proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, ..el� Michael E. Anderson, P.E. Attachments 49th MICHAEL E. ANDERSON 1,, No. CE -4381 t LOT 7, BLOCK 6, TABLELANDS SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom House 5' Wide Trench System Perc. Rate: 31-60 Min./Inch 1,500 Gallon Septic Tank Application Rate: .45 GPD/SF 4' Drainfieid Rock 5 Bedrooms X 150 GPD/.45 GPD/SF (Application Rate) = 1,666.7 SF Absorption Area 1,666.7 SF/5 SF • .5 (Red. Factor) = 166.7 LF Trench Length THEREFORE: Construct 2 - 84' Long x 5' Wide x 4' Effective Depth Absorption Trenches. Flow Line Elevation in Trenches to be 2' Below Original Ground Surface. Total Depth to be 6' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Trenches. Place Flow Splitter Valve to Insure Even Flow to Each Trench. 3' Cover Over Trench Natural Backfill 1 6" Geotextile ""14 Fabric 6"1 U4" Perforated PVC (Holes Down) ,, 4'0" I I �— Drainfield Rock 5' TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) ,gyp:•..•• •^"' NOTE: Grade Area Over Trench to Drain Away. ;' aeon Minimum 6' Separation From Bedrock. 00 ..... I• ••• ••• Minimum 4' Separation From Groundwater. 07� r'••�`-.... ' Minimum 100' Separation From Wells in the Area. 1 +, 41CM LF MXRw Minimum 10' Separation From Water Services. 0'•., No, CE4M, Minimum 100' Separation From Surface Water or Streams. ��•.., . • MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION- LOT 7 BLOCK 6, TABLELANDS S/D PERFORMED FOR- SPINFI I DATE: PARCEL ID DGPTI I (fcc0 PROJECT No•M0488 TECHNICIAN: T. L. KIMBROUGH TEST HOLE #1 SILTY ORGANICS/OB DRY BROWNISH POORLY GRADED SANDS W/GRAVELS GP—SP MEDIUM COMPACTED DRY SANDY GRAVELS GM :E SLOPE SITE PLAN CURBKEY Tot THH1 Y w $c_ FUTIRE AS9UILT �0 PERCOLATION RATE;. 42 (MINANCII) FERC. I[OLE DIA. 6 (NCI IES) TEST RUN BETWEEN. 4.5 FF. and 5.5 FT. WAS GROUNDWATER ENCOUNTERED? NO IF YES C NI IAT DEPTH'' TOTAL DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING: 10/29/04 COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE- 11/2/04 READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH OF INET WATER(INCHES) (INCHES) DROPDATE 9/28/041 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 12:05 10.0" CIIARGE 2 12:35 30 9.25" 0.75" 3 12:35 11.0" RECHARGE 4 13:05 30 10.375" 0.625" 5 13:05 11.0" RECHARGE 6 13:35 30 1 10.25"1 0.75" PERCOLATION RATE;. 42 (MINANCII) FERC. I[OLE DIA. 6 (NCI IES) TEST RUN BETWEEN. 4.5 FF. and 5.5 FT. WAS GROUNDWATER ENCOUNTERED? NO IF YES C NI IAT DEPTH'' TOTAL DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING: 10/29/04 COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY VETECH ENGINEERING TECHNICAL SERVICE. I, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE- 11/2/04 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION. LOT 7, BLOCK 6, TABLELANDS S/D PERFORMED FOR- SPINFII DATE: 9/28/2004 PROJECT No•M0488 PARCEL IDS'- TECHNICIAN: T. L. KIMBROUGH DEPTII TEST HOLE # 2 (tap 1 _- SILTY ORGANICS/OB 2 3 4 5 G DRY BROWNISH POORLY GRADED SANDS W/GRAVELS GP—SP NET TIME (MINUTES) 6 NET DROP (INCHES) 7 8 12:20 MEDIUM COMPACTED 12.0" CHARGE DRY SANDY GRAVELS 9 GM 10- 011121314 10.25" 1.75" 11- I 12- 12.0" 13- 14- 13:20 BOH 10.25" 15 16 13:20 17 RECHARGE is 13:50 19 10.25" 1.75" SLOPE 0% SITE PLAN CURBKEY Tot TH1 0 SEE FUTURE ASBU4.T PERCOLATION RATE;_ 17 OIINANCII) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4.5 PT. and 5.5 FT. WAS GROUND WATER ENCOUNTERED? NO IF YES e WHAT DE•PTIP TOTAL DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING: 10/29/04 COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFOR-MED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 11/2/04 G GLOSS TIME (MINUTES) NET TIME (MINUTES) DEPTH RF (INCHES) NET DROP (INCHES) T HOLE PRESOAKED PRIOR TO TESTING: 12:20 12.0" CHARGE 12:50 30 10.25" 1.75" I 12:50 12.0" RECHARGE 13:20 30 10.25" 1.75" 13:20 12.0" RECHARGE 13:50 30 10.25" 1.75" PERCOLATION RATE;_ 17 OIINANCII) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4.5 PT. and 5.5 FT. WAS GROUND WATER ENCOUNTERED? NO IF YES e WHAT DE•PTIP TOTAL DEPTH OF WATER AFTER MONITORING: NONE DATE OF MONITORING: 10/29/04 COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFOR-MED BY VETECH ENGINEERING TECHNICAL SERVICE. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 11/2/04 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 7, BLOCK 6, TABLELANDS SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,500 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of two new 84' long X 5' wide X 4' effective depth absorption trenches at the location also shown on the Site Plan. The distribution line in the trench will be placed at 2' below the existing ground surface. Total depth of the trench will be 6' below the existing ground surface. A Zabel Flow Splitter Valve must be placed to insure even flow to each trench. A separation distance of 200' from any well and 100' between the septic tank and absorption trench and any surface water must also be maintained. A minimum of 3' of fill is required over the absorption trenches and 4' over the septic tank. In lieu of the required fill 2" of insulation and 2' of fill may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,500 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 7, Block 6, Tablelands November 5, 2004 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 1 00'away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 7, Block 6, Tablelands November 5, 2004 Page 3 of 3 MATERIAL SPECIFICATIONS: Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Municipality of Anchorage Development Services Department • Building Safety Division : `e Onsite Water and Wastewater Program µ e 4700 South Bragaw St. s A [ T P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL SUBMITTAL COMMENT SHEET To: Anderson Engineering Legal description: The Tablelands Subdivision, Block 6. Lot 7 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. _ ❑ Additional soils information needed. ❑ Water monitoring results inadequate. ❑ Discrepancy in Information submitted. _ ❑ Topographic information missing or inadequate. _ ❑ Incomplete; missing _ ❑ Incomplete; missing _ ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. _ ❑ Locations of all soils, percolation and water monitoring tests not shown. ® Proposed system too deep for soils information submitted. Proposed system likely too deep, ❑ Well log required. ❑ Omission in narrative. _ ❑ Insufficient fill over tank or field._ ❑ Other. _ Name of reviewer. Julie Makela. P.E. Date: 11/10/04 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX November 5, 2004 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 7, Block 6, Tablelands Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 7, Block 6, Tablelands Subdivision intends to construct a new five - bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is currently served by a community water system. No conflicts exist with adjacent septic systems or wells and the proposed septic system on this lot. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The current drainage pattern is identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Test holes recently placed on the lot indicated silty sand and gravel in the area of the absorption trenches. The accepting soils were tested and found to have a percolation rate of 17 to 60 minutes per inch. The system is designed for the slower percolation rate. No groundwater was found in either test hole during placement and none was found during the monitoring period, which included the wettest period of the year. We recognize the bottom of the test hole is only 4.5' below the bottom of the proposed absorption trench. No bedrock has been encountered anywhere in Tablelands Subdivision, but the test hole will be deepened prior to construction to verify the lack of bedrock. Our design includes the placement of a new 1,500 -gallon septic tank along with 2 - 53' long by 3' wide by 8' effective depth absorption trenches to collect and treat the sewage generated in the house. The bottom of the trench will be 9.5' below the surface. The distribution pipe will be 1.5' below the surface. A flow splitter valve will be placed to assure even flow to each trench. A minimum of T of cover will be placed atop the trenches and a minimum of 4' of cover will be placed atop the new septic tank. Lot 7, Block 6, Tablelands Subdivision November 5, 2004 Page Two The ground surface on the lot slopes at shallow grades from east to west as shown on the Site Plan. The absorption trenches will be constructed parallel with the slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service proposed for the lot and on adjacent lots. It will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, n, n Yr "' 6 F. �''`� Michael E. Anderson, P.E. Attachments 7`7F j 49th 4MICHAEL E. ANDERSON \ NO. CE -4381 , LOT 7, BLOCK 6, TABLELANDS SUBDIVISION DESIGN FACTORS: 5 Bedroom Home Perc. Rate: 31-60 Min./inch Application Rate: .45 GPD/SF SYSTEM REQUIREMENTS: Deep Trench System 1,500 Gallon Septic Tank 8' Drainfield Rods 5 Bedrooms X 150 GPD/.45 GPD/SF (A plication Rate) = 1,666.7 SF Absorption Area 1,666.7SF/16 SF/LF = 104.16 LF Trench Length THEREFORE: Construct 2 New 53' Long x 3' Wide x 8' Effective Depth Absorption Trenches. At the Location Shown. Flow Line Elevation in Trenches to be 1.5' Below Original Ground Surface. Total Depth to be 9.5' Below Existing Ground. Provide 3' of Cover Over Trench and 4' Over Tank or Provide 2" of Insulation and 2' of Cover. Maintain 100' Separation Between Proposed or Existing Wells and the Septic Tank and Absorption Trench. Place Flow Splitter Valve to Insure Even Flow to Each Trench. Natural Backfill Geotextile Fabric 6" 4" Perforated PVC (Holes Down) 8'0" 1 I ,>--t— Oreinfield Rock TYPICAL DEEP TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 200' Separation From Welts in the Area. Minimum 100' Separation From Surface Water or Streams. . Minimum 10' Separation From Water Service Line. ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 7, BLOCK 6, TABLELANDS SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,500 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of two new 53' long X 3' wide X 8' effective depth absorption trenches at the location also shown on the Site Plan. The distribution line in the trench will be placed at 1.5' below the existing ground surface. Total depth of the trench will be 9.5' below the existing ground surface. A Zabel Flow Splitter Valve must be placed to insure even flow to each trench. A separation distance of 200' from any well and 100' between the septic tank and absorption trench and any surface water must also be maintained. A minimum of 3' of fill is required over the absorption trenches and 4' over the septic tank. In lieu of the required fill 2" of insulation and 2' of fill may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,500 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Municipality of Anchorage On -Site Water and Wastewater Program (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 051-801-30 1. GENERAL INFORMATION Expiration Date: 'Z- 20 /16 Complete legal description The Tablelands Block 6 Lot 7 Location (site address) 23129 Whispering Birch Dr, Peters Creek, AK Current Property owner(s) Lorenz Day phone 229-5643 Mailing address Real Estate Agent Hope Russo Day phone 301-0701 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) FEB 21 2014 3. NUMBER OF BEDROOMS: 'os 4. TYPE OF WATER SUPPLY: Individual Well ❑ Individual Water Storage ❑ Community Class C Well ❑ Public Water System TYPE OF WASTEWATER DISPOSAL: Individual Holding Tank ❑ Cbmmunity ❑ Public Sewer ❑ Received by: -`--" z � r Date: i 4S COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 1540 Date of Payment a( )/q C4_ Receipt Number 65TV2D5' COSA # O SC4q 0 O 571 Date of Payment Receipt Number Waiver 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm NorthRim Engineering Phone 694-7025 Address PO Box 770724 Eagle River Engineer's Printed Name Steve Eng 6. DSD SIGNATURE L/ System #1 Approved for System #2 Approved for Disapproved. Conditional approval for 5 bedrooms. bedrooms. Date 2/21/2014 bedrooms, with the following stipulations: Lll D O By: ��,-�i�� �Gcvta� Original Certificate Date: 'Z-/ Z The Municipality of Anchorage Devlopment Services Division (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 9-1-12 tloc If more than 1 septic system is on the lot: . COSA Checklist # _of _ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description:�%tifF %/-1 BLic,�} �//] S' B6 47 Parcel ID: O 518'0130 A. WELL DATA IVA Well type If A, B, or C provide PWSID # Well Log (Y/N) Date completed Sanitary seal (YIN)_ Wires properly protected (YIN) Total depth ft Cased to ft Casing height (above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg1L Arsenic ug/L Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material _S TFp _S Tc F[_ Date installed Tank size Z OOa gal. Number of Compartments 2 Cleanouts (Y/N) _ Foundation cleanout (Y/N) Depression over tank (Y/N) LAL High water alarm (Y/N) Date of pumping / S / Pumper �f C. ABSORPTION FIELD DATA Date installed -sSoil rating (g.p.d./ft2 or ft2/bdrm) 0#3 System typeRQ tS eJ- Bad Length /70 ft. Width /S ft. Gravel below pipe 19.5- ft. Total depth ft. Eff. absorption area 2SSOfl Monitoring tube Depression over field .A. Date of adequacy test 20 / Results (Pass/Fall) For _5_ bedrooms Fluid depth in absorption field before test in. Water added ]SU' gal.New depth O in. Elapsed Time: min. Final fluid depth in. Absorption rate >_ ,SSa g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) Ali) diffik:: If yes, give date D. LIFT STATION Date installed Size in gallons Z -S Manhole/Access (YIN) "Pump on" level at in. "Pump off" level at �_ in. High water alarm level at ` in. Datum AS d 7 A *+, Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES AC WELL ON LOT TO: / v A Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer /septic service line Animal containment areas On adjacent lots On adjacent Public sewer manhole/cleanout Holding tank Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation S Property line /D Absorption field S f Water main /Lf'f Water service line /� �f Surface water /0 6 Wells on adjacent lots 20 d "i" ABSORPTION FIELD ON LOT TO: Property line /r? "f Building foundation /� f Water main /�Q Water Service line Y/— 4 —/_Y Surface waterI G6 If- Driveway, parking/vehicle Storage— Curtain drain 46d/GL Wells on adjacent lots F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineers Printed Name Date COSA brown sheet_10-10-12.doc Municipality of Anchorage Development Services Department ' Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. ww P.O. Box 196650 Anchorage, AK 99519650 J ww 7ge.ak.us (90)343-7904 o• aY e S• tTr C� `� C- " CERTIFICATE OF HEALTH AUTHORITY APPROVAL C FOR A SINGLE FAMILY DWELLING Parcel I.D. 051.601.30 HAA # OS025�1 Expiration Date: I V4! 0 A?7U p 1. GENERAL INFORMATION Complete legal description Lot 7, Block 6, The Tablelands Subdivision Location (site address or directions) 23129 Whispering Birch Drive Current Property owner(s) Spinell Homes, Inc. Day phone 344.5678 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address 1900 Northern Lights Blvd. Anchorage, AK 99517 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System Five 5 Day phone Day phone TYPE OF WASTEWATER DISPOSAL: ❑ Individual On-site ❑ Individual Holding tank ❑ ❑ Community On-site ❑ ® Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30.days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522.7773 Address _ P.O. Box 240773 Anchorage. AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. Date 611512005 5. DSD SIGNATURE Approved for bedrooms. Disapproved. Conditional approval for _rte bedrooms, with the following stipulations: Six inches of topsoil must be placed on the mound absorption field and be sufficiently vegetated to prevent erosion. The work shall be completed no later than 7/31/2005. HAA Checklist X Maintenance Agreements Septic System Advisory Supplemental Engineer's Report Well Flow Advisory Other BY �D Q_�� h 0` 0,6' Original Certificate Date:It S (ra,.. IZW) E Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Brag" St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: _ Lot 7. Block 6. The Tablelands Subdivision Parcel ID: 051-801-30 A. WELL DATA Well type Date completed _ Total depth ft. Date of test Static water level if A, B, or C provide PWSID # Sanitary seal (Y/N)_ Cased to ft. FROM WELL LOG Well production WATER SAMPLE RESULTS: ft. Well Log (Y/N) Wires properly protected (YIN) Casing height (above ground) in. AT INSPECTION ft. Coliform oolonies/100 ml. Nitrate mg.fl. Other bacteria colonies/100 mi. Date of sample: Collected by: B. SEPTICIHOLDING TANK DATA Tank Typeftaterial STEPISteel Date installed OW005 Tank size 2.000 gal. Number of Compartments 3 Cleanouts (Y/N) Y Foundation cieanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) Y Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA Date installed 61912005 Soil rating (g.p.d./W or ftz/bdrm).3 GPDISF System type Raised Bed Length 170 ft. Width J5 ft. Gravel below pipe _.5 ft. Total depth Q ft. Eff. absorption area 2.550 fF Monitoring tube Y Depression over field N Date of adequacy test Results (Pass/Fail) For _ bedrooms Fluid depth in absorption field before test _ in. Water added_ gal. New depth_ in. Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) _N If yes, give date D. LIFT STATION Date installed 61812005 • Size in gallons 250 ManhoWAccess (Y/N) Y 'Pump on' level at 42 in. 'Pump ofr level at!Q in. High water alarm level at 44 in. Datum Bottom of Tank Cycles tested New Construction Meets alarm & circuit requirements? Y E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot NIA Absorption field on lot NIA Public sewer main NIA Sewer /septic service line NIA On adjacent lots NIA On adjacent lots NIA Public sewer manhole/cleanout NIA Holding tank NIA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >T Absorption field >S Water main >10' Water service line >10' Surface water >100' Wells on adjacent lots >200' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >10' Water main >10' Water Service line >10' Surface water. >100' Driveway, parking/vehide storage >5' Curtain drain None Noted Wells on adjacent lots >2W F. COMMENTS G. ENGINEER'S CERTIFICATION �P:.= """"'^l I candy that I have determined through field inspections and 49th review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. _ _. rauaa �rmcrrssoi Engineer's Printed Name Michael E Anderson. P.E. `i `• Na cc -4= Date 6175105 •e•4a�iSS�� HAA Fee $ S7 'f" % !7V° % via. fi A ft Date of Payment to, fes, pOS Receipt Number (Rev. 12100) t'n Fee Date of Payment Receipt Number ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 FAX MEMORANDUM DATE: June 15, 2005 TO: Julie Makela, P.E. FROM: Mike Anderson, P.E. SUBJECT: Lot 7, Block 6, The Tablelands Subdivision Conditional Health Authority Approval The owner of Lot 7, Block 6, The Tablelands Subdivision intends to place topsoil and seeding on the newly constructed mounds, but cannot accomplish the task until later this month. We are therefore requesting a conditional Certificate of Health Authority Approval be issued so the property can be closed. Attached is the as -built of the recently reconstructed septic system along with the Health Authority Checklist and the Certificate of Health Authority Approval. A fee of $115.00 has been paid for the issuance of the conditional certificate along with the fee of $175.00 for the rush approval and $57.50 for the engineer review. Please let me know if you have any questions. O N i 0 N z 0 m.' z 0 0 O 70 z m N U) 2 U) 0 I � m =N mr7C C mCc) M�A0ao " N r O O C A D cn Pto ZZ7 C N om. C r-. mxcar)0=i'''-° D 0mo--Do AOm z amri m� pm; _mZAz�=aim O Vl z z m = � '< �mOzm ZUnm -Xr 0 0 C) n-aoxcnzr"� m CO N n m A m m N rn 0O'O�:L7f�nXNmm C OTNI n-I�CO un.7- o ;u Z706zr�-' z't 0,0 0 -i 0 :� X Oo - C) oZi)GOMOO�„x � �Z. oco=)zzm >-+� ox o { z rn0 z0N-rz-"rnDoo nx -nOZoo1 --4o Fn cn + e.SILrIIa b AFia,' j a ` H f • M 10 • ♦ goo'••, ♦� O'S ••••• ,. Cj •• ti N O O �P I N 0