HomeMy WebLinkAboutTHE TABLELANDS #1 BLK 8 LT 20The Tablelands Block 8 Lot 20 #051-801-65 Municipality of Anchorage Page 1 of 3 Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196850 Anchorage. AK 99519-6650 www4anchorage.sk.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SWO50295 PID Number. 051 -BOM S inell Homes Wastewater System: New Art 1900 W. Northern LI hts Ste. 200 Anch., AK 99517 ABSORPTION FIELD ptxM 344-5676 " h eea 3°°" 5' Wide Trench LEGAL DESCRIPTION Sod lt�'aTaW Depth Yomrp.WWeft .7 wwr 3 Ft. 11 tl La B.edlM.bc S Dpm b P" basin kr. MiVW VW. G.vr E.pm CrwWr pp 20 The Tablelands 1 Fr. 2 FL Taw, Rrpr. s.tdwT FA add.d.bo rqa grade D....i LrpUi 1.3 Ft. 90 Ft. Well: AWWU Water System NunOia1i" D"'rpDMi'°n"" 5 Ft. 1 cxr.d (Pm . A a. C}. Tarr D"ftCuM xr abswpl r.a pa rW. Ft. FL 643 Ft' ASTM 3034 PVC pa.r. Dr. Mort ams WOW L.vr. Ft Pisano's Dirlworks 919/2005 YrNd Prep sr r. Cana H.VN Aaw. crud: TANK DPL. Fr. FL SEPARATION DISTANCES Septic To Septic Absorption 1M Holding WwPrtata . From Tank Field Station Tank sewerune Anchorage Tank 1,000 WN >200' >200' N/A WA >25' Steel Two (2) s.ra.wrr >100' >100' WA NIA LIFT STATION — NONE ON LOT Lnr l}r >5' >10, WA WA cr FauMrbn >5' >10' WA WA „ „ Dr.t . None Noted71 Pmrwkw BENCH MARK 2 of Insulation Over Entire System. r Finished Floor. 100.0 FL Engineer's Stamp '.*gyp F silt a•4•�a0 Inspections performed by: T. Kimbrough Dates: 1d 91912005 �` 49th L� `� 00 2nd 91912005 Department of Health and Human Services approval V♦ C14 CHAEL E. ANDERSON / —}— Reviewed and approved by: lJ A Date:3 zR-fl6 ♦ if No. CE -4391 •sss�pfp (M 1(10))4e�ea"� SSIO' ��• Municipality of Anchorage N e9'52'01'E DEVEOPMENT SERVICES DEPARTMENT Permit No.: SW050295 23 4700 South Bragaw Street Anchorage, AK 9951M55 -343.7904 PID No. 051-8015 1 \ Onsite Wastewater Disposal System or Well Inspection Report Page 2 of 3 49th 6V MICHAEL L ANDERSON s} NIL su ali 41.r THE TABLELANDS, ADDITION NO. 1 LOT 20, BLOCK 8 54,088 S.F. S PLAN AS -BUILT SCALE 1' = 50' T. h E. ESWr. BLACKTAIL CIRCLE Permit No. SWO50295 Municipality of Anchorage Page 3 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report PID No. 051-801.65 abrlc � i •J49t �k�� PROFILE AS -BUILT Scale: t' - 20' OXV;T UEL c ANDERSaN I N MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Aug 17, 2005 Expiration Date: Aug 17, 2006 Permit Number: SWO50295 Parcel ID: 051-801.65 Legal Description: THE TABLELANDS #1 SUBDIVISION BLOCK 8 LOT 20 Design Engineer: 0014 Anderson Engineering Site Address: 22416 BLACKTAIL CIRCLE Owner Name: SPINELL HOMES, INC Lot Size: 54088 SO. FT. Owner Address: 1900 W. NORTHERN LIGHTS BLVD #2( Total Bedrooms: 3 Permit Bedrooms: 3 ANCHORAGE. AK 99515 - This permit is for the construction of: ❑7 Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. a.) The total depth of the absorption field shall not exceed 3 feet below original grade. Received By: Issued By: Date: 6-49-'01- Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ek.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. D _"�l- 96 I- /n 5 Permit Number SW Property owner(s) Sainell Homes, Inc. Day phone 3445678 Mailing address (1)1900 W. Northern Lights Boulevard, Suite 200 Anchorage, AK 99515 Mailing address (2)'"411,* 9lacktail Circle Zip Code Legal description (Lot, Block & Sub'd.) Lot 20 Block B The Tablelands Subdivision, Addition No. t Legal description (Section, Township & Range) Lot Size 54.088 SF Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms Three (3) Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: ``L 0 W Waiver Fees: Date of Payment:PJ[) — CSS'" Or _ Date of Payment Receipt Number.7ZOli� Receipt Number. (Rev. 12/00) ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) MEMORANDUM DATE: August 16, 2005 TO: Julie Makela, P.E. FROM: Mike Anderson, P.E. SUBJECT: Lot 20, Block 8, The Tablelands Subdivision Septic System Design We have revised the site plan to include the location of the subdivision test hole. We have also modified the length of the trench to 90' compensate for the slower percolation rate. We have used an average absorption rate of .7 gallons per day per square foot and increased the length of the trench to 90'. We are confident the trench will be effective in the absorption of the septic effluent generated in the house. Please review the attached documentation and call with any questions. ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766_(F August 6, 2005 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 20, Block 8, The Tablelands Subdivision, Addn. No. 1 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 20, Block 8, The Tablelands Subdivision, Addition No. 1 intends to construct a new three-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the new home. The subdivision is currently served by a community water system. No conflicts exist with adjacent septic systems or wells and the proposed septic system on this lot. The attached Site Plan and backup documentation identify the location and configuration of the proposed septic system and alternate site. The current drainage pattern is identified on the Site Plan. The drainage pattern will be maintained after development of this lot is complete. Test holes recently placed on the lot indicated silty gravel with minor amounts of sand in the area of the absorption trench and alternate site. The accepting soils were tested and found to have a percolation rate of between 6 minutes per inch and 15 minutes per inch. The system is designed with an application rate of .8 GPD/SF. No groundwater was found in the test holes during placement and none was monitored during the ensuing period. Our design, however, is based on the bottom of the trench at 3' below the surface and includes the placement of a new 1,000 -gallon septic tank along with an 80' long by 5' wide by 2' effective depth absorption trench to collect and treat the sewage generated in the house. The distribution pipe will be 1' below the surface. A minimum of 3' of cover will be placed atop the trench and a minimum of 4' of cover will be placed atop the new septic tank. The ground surface on the lot slopes at varying grades from southeast to northwest as shown on the Site Plan. The absorption trench will be constructed parallel with the Lot 20, Block 8, The Tablelands Subdivision, No.1 August6,2005 Page Two slope of the ground surface as much as possible in conformance with Municipal requirements. The new septic system will be constructed a minimum of 10' from the water service proposed for the lot and on adjacent lots. It will also be constructed a minimum of 1 00'from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, rn"J" Eale-, Michael E. Anderson, P.E. Attachments 49th 1 MICHAEL E ANDERSON i No. CE -4381 . N89'S2'Ol'E Q0. 23.83' 5/8' MM (TYP PER PLAT) 2004-131 THE TABLELANDS, ADDITION NO. 1 LOT 20, BLOCK 8 54,088 S.F. i` A J, O 10 n 0 11 2 e{ 1xz wi.� aro � • m� ESMT. �Ae.>ge. 1...e. °'+ • 'P� 15' T. k E. r , 100• At. S 76*;;p. 230.0)' it � /• SLACKTAIL +••••������, CIRCLE • •�� pF �..•Q ��' •".. `c d� 120• zt 49tl�%,5.�•dd �y i NICNNEL E ANDERSON r' .` -i i •, f: N0. cE-4791 frytiZ: SITE PLAN ••�4•1ESSii•••` SCALE 1' = 50' LOT 20, BLOCK 8, THE TABLELANDS, ADDN. NO. 1 DESIGN FACTORS: Three Bedroom House Perc. Rate: 6-17.2 Min.Anch Application Rate: .7 GPD/SF (AVG. Rate) SYSTEM REQUIREMENTS: 5' Wide Trench System 1,000 Gallon Septic Tank 2' Drainfield Rock 3 Bedrooms X 150 GPD/.7 GPD/SF(Application Rate) = 642.86 SF Absorption Area 642.86 SF/5 LF (;Width)" .7(Red. Factor) = 90 LF Trench Length THEREFORE: Construct a 90' Long x 5' Wide x 2' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be V Below Original Ground Surface. Total Depth to be 3' Below Existing Ground. Provide 4' Cover Over Septic Tank and 3' Cover Over Absorption Trench. 6" 6" 2'0" Natural Backfill 5' 3' Cover or 2" Insulation and 2' Cover Geotextile Fabric 4" Perforated PVC (Holes Down) Drainfield Rock TYPICAL 5' WIDE TRENCH SE NOTE: Grade Area Over Trench to Drain Away. Minimum V Separation From Bedrock. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum 100' Separation From Surface Water or Streams. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION. LOT 20. BLOCK 8. TABLELANDS S/D PERFORMED FOR- SPINELL HOMES, INC. DATE: 7/29/2005 PROJECT No- M0562 PARCEL ID,y TECHNICIAN: M FI DRIDGF DErn1 TEST HOLE # 1 (rcn) 1 READING OB/OG NET TIME (MINUTES) 2 = 7/29/05 TEST HOLE PRESOAKED PRIOR TO TESTING: 1U 3 11:01 11.0" CHARGE 2 11:31 30 5.25++ 12- 2 3 6}.. 11.0" RECHARGE 13-- 13 7 BOH POORLY GRADED GRAVELLY - 14- 415161719 5.5++ SANDS SOME FINES 8 5 SP -GP 9 READING OSS TIME G MINUTES) NET TIME (MINUTES) DNATER (INCHES) NFT DROP ( INCHES) 7/29/05 TEST HOLE PRESOAKED PRIOR TO TESTING: 1U •.i: '7. 11:01 11.0" CHARGE 2 11:31 30 5.25++ 12- 2 3 11:31 11.0" RECHARGE 13-- 13 4 BOH 30 14- 415161719 5.5++ 15- 5 12:01 16- 11.0" RECHARGE 17- 6 12:3130 5.63" 19 COMMENTS: WAS GROUNDWATER ENCOUNTERED' NO SITE PAN THI O SFF FUTURF ASRUR.T IF YES ® WIIAT DFPRI'"'°I <5% DEPTH OF WATER AFTER MONITORING O% DATE OF MONITORING 8141NM DATE READING OSS TIME G MINUTES) NET TIME (MINUTES) DNATER (INCHES) NFT DROP ( INCHES) 7/29/05 TEST HOLE PRESOAKED PRIOR TO TESTING: I 11:01 11.0" CHARGE 2 11:31 30 5.25++ 5.75" 3 11:31 11.0" RECHARGE 4 12:01 30 5.5++ 5.5++ 5 12:01 11.0" RECHARGE 6 12:3130 5.63" 5.37' PERCOLATION RATE: 5.8 (MINANCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 5 Fr.and 6 Fr. TEST HOLE PRESOAKED PRIOR TO TESTING. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE* MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT ����Q'^••..••.'��j 4700 SOUTH BRAGAW STREET ANCHORAGE, AK 99519-6650 7*49th r � _49th SOILS LOG - PERCOLATION TEST- �NtcNAEt E. ANRERSW LEGAL DESCRIPTION LOT 20, BLOCK 8. TABLELANDS S/D ,i� � No. cr.-4 { PERFORMED FOR- SPINELL HOMES INC. — ��h�� n •'� DATE: 7/29/2005 PROJECT No' M0562 Professional Engin Slam PARCEL ID -j• TECHNICIAN: M FI MIDGE DrPTII TEST HOLE # 2 (fcct) OB/OG SLOPE SITE PAN — 'y.� 2 e� �r 3 4 0 5' ` .�: o O v TH2 6 •:a'. iy 4yI y .• 7 ';:.;•' MOIST SITLY SANDS •�' :' SOME GRAVELS W/FINES 8 ': �•; ' SM -SP 9 '• �: i. SFF FUTU RF ASNIIILT 10 WAS GROUNDWATER ENCOUNTERED' Nn . , IF YES ®WIIAT DEFIAT 500 r�=•'�'•+ DEFT11 OF WA7ER AFTER MONITORING N^e 0% 11 : i•. DATE OF MONITORING: <l0% 12 �. .... 13 '; ";� BOH 14 15 16 17 18 19 20 PERCOLATION RATE: IO.0(MIN/INCFt) PERC. IIOLE DIA. 6 (MCFIES) TEST RUN BETWEEN.5 FT. and 6 FT. COMMENTS: NO IMPERMEABLE LAYERS ENCOUNTERED. TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1, MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON TFIIS DATE- G OSS TIME NET TIME �rygTERF INFT DATE READINGMINUTES)(MINUTESNCHES (INCHES) DRP 7/29/05 TEST HOLE PRESOAKED PRIOR TO TESTING: 1 11:35 11.0" CHARGE 2 12:05 30 8.19" 2.8125" 3 12:05 11.0" RECHARGE 4 12:35 30 8.19" 2.8125" $ 12:35 11.0" RECHARGE 6 13:05 30 8.0" 3.0" titlVtildHtt1i�tllil lay�W�@4 t1c���1�t+�Nl � �_� rpt ?� � -F 'teOA ty-bod W4161 wsd§14"Iel blodt9M �• �•• •� J�dtl IN idia(sl .r+ P.d. t)oi 19t6stl I3de, AIC 69519 -Fetid stoom CE 8801 Cowu1 (90�) saeo 4p btillg Ldd : 06voildlltili tw;t Nf6hkdfoc Turner Constructiott.. balebnlonned:11/27/02' I � •� � � I I I I bbftbbLAikA PAR .. / L.ir.Uu,61 btkc lblt bWktth IL91HU)bf OW, ff 1Mf 5 ft bEhflilltatltUr: �•�+8�H kGnuf,llt�+ttutts cr—bIttsHbtAIhiYt.111AltAfttN:k1tWitmtDINAbbtilitUhhwiv �'Ils�itStWA'; i 6 �- 9 ♦ � D ♦ ry ; j �0 8 ♦ Ij ' ' p; ' I - - 1 l 3�n 7 2 q 6 Al 2 1 3 j 4 5 , DEED 1 ���!' LOT j r----ra------- � g I I I I I 1 8 �� 1 \ � I 1 � I 1 I I I I 10 300' I December, 2002 --'------ j-- --1-------- ntl' 4 S , .I 6i /♦ j 2 1 i 2 IjC• 6 I� TRACT I m OGS 0" 19 18 20 382 8 OL28 21 17 H+. pL182 7pl/ OLt '4 PA 5 1 V. J TH-2 3 20 JTH TH-1 4y 5 4 6 i-�- 7 8 9 2 ur 3 10 /' 4 11 5 12 ; 6 13 B 7 m� i5 TRACT G 7/! 21 22 10 9 10 ' 15 18 17 16 19 TRACT 8 ;ACT A 2 3 22 '' � ` `� ti 210 2311 24 25 20 ________________________ ________ � 20 i is 1 1 ,y 21 - I 1 1' 181191 1 --7---I---r---------- ham\ 19 I I I 17 I I I I TRACT A k 18��y�I `�+------� I 1 1 2 1 3 1 4 1 i - BESSE ENGINEERING TEST BORING MCMANUS PARCEL 1690 w. ja6mc unite tlrde GEED LOT (BOOK 469, PACES 155 3 156), ANCFIORACE WASLLA. AK. 99651 LOCATION .MAP RECORDING DISTRICT. LOCATED WITHIN THE NE 1/4 907-357-4257 -SECTION 4,;T15N, R1W, SEW'ARD. MERIDIAN, ALASKA. ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 20, BLOCK 8, TABLELANDS SUBDIVISION, NO. 1 GENERAL: The scope of this project includes the procurement and placement of a new 1,000 -gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 80' long X 5' wide X 2' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 1' below the existing ground surface. Total depth of the trench will be 3' below the existing ground surface. A separation distance of 200' from any well and 100' between the septic tank and absorption trench and any surface water must also be maintained. A minimum of 3' of fill is required over the absorption trench and 4' over the septic tank. In lieu of the required fill 2" of insulation and 2' of fill may be placed. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION A new 1,000 -gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. Lot 20, Block 8, Tablelands No. 1 August 6, 2005 Page 2 of 3 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. Lot 20, Block 8, Tablelands No. 1 August 6, 2005 Page 3 of 3 MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Municipality of Anchorage Development Services Department +1 Building Safety Division Onsite Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWERIWELL SUBMITTAL COMMENT SHEET To: Anderson Enaineerina Legal description: The Tablelands #1. Block 8. Lot 20 The attached paperwork has been reviewed and is being returned for the following reasons: ❑ Original signature or stamp missing on ❑ Calculation error in design. _ ❑ Additional soils information needed. _ ❑ Water monitoring results inadequate. ❑ Discrepancy in information submitted. ❑ Topographic information missing or inadequate. ❑ incomplete; missing _ ❑ Incomplete; missing _ ❑ Additional adequacy test information needed. ❑ Water sample unacceptable. _ ❑ Measured/proposed distances/dimensions missing. ❑ Locations of all soils, percolation and water monitoring tests not shown. ❑ Proposed system too deep for soils information submitted. ❑ Well log required. ❑ Omission in narrative. ❑ Insufficient fill over tank or field.— ® Other. 1) Two different test holes designated os '"THl." Please is Name of reviewer: Julie Mokelo. P.E. Date: 8/11/2005 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK 4ndkilemodu. Municipality of Anchorage Development Services Department ' Building Safety Division On -Site Water and Wastewater Program ' 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-665o www.muni.org/onske (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051.801-65 COSA # Expiration Date: 3 - o-7,9 -0'-2 1. GENERAL INFORMATION Complete legal description Lot 20. Brock S. The Tablelands Subdivision No.1 Location (site address) 22418 Biaddall Circle Chuglak, AK Current Property owner(s) Spinae Hanes, Inc. Day phone 3445678 Mailing address 1900W. Nathem Lights Blvd., Suite 200 Andwrage, AK 99517 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pi kup. 2. NUMBER OF BEDROOMS: Three (3) 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site R1 Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given In paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Onsite Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues COSAs upon request to homeowners. Certificates of Onsite Systems Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for mors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of Onsite Systems Approval Guidelines for this application, shows that the on-ske water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the Information obtained from the Municipality of Anchorage files and from my Investigation and Inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of Installation. Name of Finn Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. 6. DSD SIGNATURE ✓ Approved for 3 bedrooms. Disapproved. Date 3/2120013 49th Conditional approval for bedrooms, with the following stipulations: COSA Checklist _X Arsenic Advisory Septic System Advisory Maintenance Agreements Well Flow Advisory Supplemental Engineer's Report Nitrate Advisory Other By:c "I Original Certificate Date: 3 ' R ' O 6 CA - (11". 1 W) Municipality of Anchorage • Development Services Department Building Safety Division Onsite Water 6 Wastewater Program 47W Bragaw Street P.O. Bax 196050 Anchorage, AK 995198650 www.munLorglonake Mn 3437904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Let 24, Block a, The Tsbr www sub& i aan No. t Parcel IQ 0 1-001.85 A. WELL DATA Web type _ If A, S. or C provide PWSID 0 _ Wen Log (YIN) Date completed _ Sanitary seal (YIN) _ Wires pmp&V protected (Y/N) Total depth fL Cased to ft. Casing height (above ground) in. FROM WELL LOO AT INSPECTION Date of teat Stats water level ft. ft. Well production g.p.m. p.p.m. WATER SAMPLE RESULTS: Coliform cokxlleahW mL Nitrate mg& Other bacteria colontes/100 mL Arsenio. _ mgn Date of sample: _ Collected by: B. SEPTICIHOLDINO TANK DATA Tank Type/Material _ aepadsw Date installed 92AM Tank sae 1.000 gal. Number of Compartmerds s Cleanouts (YIN) v Foundation cleanout (Y" Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping New ConsrnuM n Pumper C. ABSORPTION FIELD DATA Date Installed 9=2005 Son rating (g.p.dJf? or felbdrm) LG -POW System type s vane Trench Length =o R Width a ft. (travel below pipe 2 ft. Total depth _1±__A Elf. absorption area ffl­fe Monitoring tube Y Depression over field N Date of adequacy test Now Canes Results (Pass/Fall) For _ bedrooms Fluid depth in absorption flew before test in. Water added_ gal. New depth in. Elapsed Time: min. FMW fiukl depth in. Absorption rate a- g.p.d. Any rejuvenation treatment (past 12 mo.) (YIN 6 type) N If yea, give date D. LIFT STATION Data installed Size in ga0ons 'Pump on' level at _ In. 'Pump off" level at _ in. Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAift station on lot Absorption field on lot Public sewer mein Sewer /septic service line Animal containment areas Manhole/Access (Y/N) High water slam level at in. Meets alarm & dreu t requhmerds9 On adjacent iota On adjacent iob Public sewer manhoWdeanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTICMOLDINO TANK ON LOT TO: Building foundation >s' Property line >& Absorption field >s Water main »a Water service line >ia Surface water :-JW Wells on adjacent kits >2ea SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property One »a Building foundation >V Water main >+a Water Service One »a Surface water »ar Ddveeay Psi W"hide smrepe >25' Curtain drain None Ned Wells on adjecent bts >1W F. COMMENTS: Ld y rived by AWwu weer sy.rem. G. ENGINEER'S CERTIFICATION I cerw that l defand review 4 } ai M records that the above � systems are in ..9th-, cordormance wllh MOA COSA guidelines io effect on this date. Engineer's Printed Name Michael E. Andm%M P.E. raoaa L ANOM a a-ast Date 9127r2008 il S' -r L COSA Fee S Waiver Fee $ _ Date of Payment Jr- 2 fr--O 6 Date of Payment Receipt Number Receipt Number, (Rev. I IMM ���oollouolrs�lo� ♦ 06 •.. •.• °.. � e�•a�i 1609—S1 •�-°ii•� � IDIo1so0 y tirNM . : � ;•6.:;........ 6b::co i 3108 lIV1NDV 'lYiS3 '3 V '1 ,91 31VO SIHI 13S S83N800 ON :31ON VNSVIV '101N1SI0.0NION0038 30VNOH0NV 'S3NIl 30N3d NO ANV(]Nn08 ONIHSIl8V1S3 NOd NO N0110n8iSNOO NOd 03Sn 38 NO3N3H Vivo ANV OInOHS S30NVISWn0NI0 ON N30Nn '1Vld NOISIA108nS 030N003N 3H1 NO NV3ddV ION 00 H01HM SN01101N1S38 NO S1NVN3A00 'S1N3W3SV3 .INV AO 30N31SIX3 3H1 3NIMM30 Ol N3NM0 3H1 d0 A11118ISNOdS38 3H1 SI 11 '031VOIONI SV Id30X3 1SIX3 S1N3WHOVON0N3 ON 1VH1 ONV 3A08V 03131d3O A1N3dONd 3H1 03,k3ANnS 3AVH 11VHI ALUM A83N3H I 90Zs11 1 91—SO 'ON sor I '8'd SOOZ/9Z/Z�10 16991 MN 0121) 4949-84Z 3NOHd Z0966 VNSVIV '30VNOHONV 3nN3AV H199 1S3M 9ZL4 'S'l'N '101V1SVO 'V dd3f 0l1 'JNIumnS ONVI IOIVISVO i� 3.10,ZS.69 N 'd'S 8901'9 8 A30-18 0Z iM L 'ON NOWCICI ' `SGNV3-18V-L 3Hl «l -400Z 30N3! ,0v=,, L