Loading...
HomeMy WebLinkAboutDENALY TR A1benaly #2 Lot 46 #067-062-06 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water 8 Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WATER SUPPLY PERMIT Initial Permit Number: SWO50305DFN44Ly 42.[or y6 Legal Description: Design Engineer: 0855 Garness Engineering Group, LTD Owner Name: EKLUTNA INC Date Issued: Aug 22, 2005 Expiration Date: Aug 22, 2006 Parcel ID: 067-062-06 Site Address: NHN Lot Size: 0 SO. FT. Owner Address: 16515 CENTERFIELD DR Total Bedrooms: 0 Permit Bedrooms: 0 EAGLE RIVER. A 99577-7719 This permit is for the construction of. Disposal Field [:] Septic Tank Holding Tank ❑ Privy Private Well E] Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. -WHEN THE WELL HAS BEEN COMPLETED AND SATISFACTORY WATER PRODUCTION HAS BEEN DETERMINED, THE WELL DRILLER SHALL PLACE AN APPROVED SANITARY SEAL ON THE WELL HEAD AND NO PITLESS ADAPTER OR PUMP SHALL BE INSTALLED UNTIL AN APPROVED WASTEWATER DISPOSAL SYSTEM HAS BEEN CONSTRUCTED. gi-THIS PERMIT IS FOR THE PROPOSED DENALY S/D #2 LOT 46 t Received By: Date: rr- 'Q? -Cly Issued By: Wit[" Date: v �� Municipality of Anchorage ' Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR ASINGGLE FAMILY DWELLING Parcel I.O. u -tn- FJ( Dot //- 467 Permit Number Property owner(s) FKLUTNA INC. Day phone 696-9R9A Mailing address (1) _ 16515 CFNTFRFIELD DRIV • FAGLE RIVER. AK Mailing address (2) Zip Code 99577 Legal description (Lot, Block & Sub'd.) TRACT Al. DENALY S/D; (PROPOSED LOT 46, DENALY S/D #2) Legal description (Section, Township & Range) N/A Lot Size _2 r 9 IS, I L44& Acre q.Ft. Number of Bedrooms — N/A THIS APPLICATION IS FOR: Sewer Only ❑ Well Only 0 Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. Permit Fees:• V V Date of Payment: s � Receipt Number: `�gy53 Waiver Fees - Date of Payment: Receipt Number. GARNESS ENGINEERING GROUP, Ltd. CONSULTANTS 8 GENERAL CONTRACTORS riiiiiiiesii August 4, 2005 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Exploratory Wells for Proposed Denaly Subdivision Phase 2, We request a well permits to have three exploratory wells on the proposed lots 32, 45, and 46 of Tract A-1, Denaly Subdivision for the purpose of subdivision. Attached is a site plan for the proposed well locations. After completion of the wells, a draw down test will be performed on these three wells for the purpose of subdividing the properties. ns, please contact us at 337-6179. Thank you for your assistance. I., M.S. 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: gamessenginecring.com r 1 \\{1 LOT 43 �\ \ LOT 44 I F /LOT 34 / X7:7 LOT I51`+--------Tey-----'e. AREA 10,000 SO.Fr. \ 1� TN/sl — �� '1 LOT 521 TIC RE E`` \\ \\ I AREA 10.000 ``�• SOFT. TH14 EA 10.000 SO.Fr 152 1 � / I``` /LOT 45� l` 1` PROPOSED 100• 1 LOT 46 wf4 RADIus TN14 ESFRVE AREA LO 47 100 %%%. \\ 0 WASTEWATER`\` iN/4°e \ SEPTIC RESERVE \ `� TIC \ \ (SEE NOTE) RESERVE \ ��.`` MEA 10. \ \\ TN147 THI 0.000 / /^\ 110 GARNESS ENGINEERING GROUP, Ltd. p;�: 4 CONSULTANTS & GENERAL CONTRACTORS . »� E. nnoA �. n.0: 10l . w.oroA.cE. wf TaeoT . w.oa morn • ru TI7.1ea1u • .ceslrt:.... .•,,, 0 PREPARED FOR: PNONENUMBER: PACE NUMBER: .. .. ........ ........ EKLUTNA INC. 696-2828 1 OF Iv r Gar ess: LEGAL DESCRIPTION: DRAWN BY: PROPOSED DENALY SUBDIVISION #2; LOT 46 C.J.G. �D��er� ••!� (p/pY(1%a TYPE OF WORK: DATE: Q4 Pro Fes$'Of`°ao SITE PLAN FOR PROPOSED WELL 8/9/2005 ��DOpoo�c Aus.19. 2005 9:19AM Garness Enaineerins Group. Ltd. M -W Dri//m9, Inc. 19 August 2005 To: Garness Engineering Group Attn: Jody 33g-32A&v (1) Paye -rota! Rt' Denaly Subdivision, Engle River Subject: Hi -head ortesion well - construction mitigation measures. bear Sir. No.8575 P. 2 Water well construction/ drilling In the above referenced subdivision hos commonly encountered hi -head and hi -flow conditions front the main unconsolidated aquifer oround 200_ feet. Measured characteristics can be on the order of 300_ 9" free flowing with a shutoff head of 20 psi (ie. •46 feety Following are the construction measures we have used to successfully control these characteristics on the first five (5) wells In this subdivision. 1) Continuously dry grout throughout the total length of the cased well bore (Ie. 10-12 sacks of No. 8 bentonite granules per well). 2) Allow the welt to flow controlled without excessive pressure buildup, for several days to allow the dry grout to hydrate and bind with the surrounding formation material. 3) Shut-in the well with our fabricated, mechanical, artesian well packer - which holds the water level down below the froshlirk, We have been pleasantly surprised by the ability of the dry grout to hold and prevent washout (is. vertical up/down water flow) of the well casing annulus. This also constitutes Proof of the ability of the dry grout method to prevent vertical dower movement of contaminwnts in the casing annulus. ♦P.O. Box 110378+ Anchorage, AK 99511♦ 0hone: 907-345-4000*Fax: 907-345-3287* 0 s are our bus/Mess!!/