Loading...
HomeMy WebLinkAboutMCKINLEY HEIGHTS #1 BLK 7 LT 1McKinley 'D Heights #1 Block 7 Lot 1 #051-213-21 Oct_10.2022 09:23 AM Anchorage Well & Pump Service Inc 9072430742 #1274 P 1/ 1 MUNICIPALITY OF ANCHORAGE Afte Development Services Department Phone: 907343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Number: Date of Issue: -� Parcel Identification Number: 051213 - 21 )Legal Description Block Lot Property Owner Name & Address: MOODY WILLIAM & HANSON HE=ATHER MCKINLEY HEIGHTS #1 7 1 18221 AMONSON RD CHUGIAK, AK 99567 Pump Installation Date: 10 - 07 - 2022 Pump Intake Depth Below Top of Well Casing: :330 feet Pump Manufacturer's Name: STA -RITE Pump Model: UNDHL-06 IPump Size: .7 hp Pitless Adapter Burial Depth: 8 feet Pitless Adapter Manufacturer's Name: ME=RRILL MANUFACTURING Pitless Adapter Installer: HILAND EXCAVATION Well Disinfected Upon Completion? Yes ❑ No Method of Disinfection: PELLETS I Comments: II Pump Installer Name: _ II Company: II Mailing Address: __....._... ANCHORAGE WELL & PUMP SERVICE 7640 KING STREET ANCHORAGE, AK 995I8 907-243-0740 11 City_ State: Zip: �I Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation. Municipality of Anchorage Development Services Department 3jj� jy. Building Safety Division On -Site Water and Wastewater Program, 4700 Bragaw St. / P.O. Box 196650 Anchorage, AK 99519-6650 Page of •3 www.ci.anchorege.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number:.5dO 50330 PID Number: 05/-Z! 3-2 / "'N"O Wastewater System: ew [IUpgrade Ad"vNp�zZ/ 1" (J0A1 R ABSORPTION FIELD aD3 Numbw M BMroomF Phan il lr— 0633 0 D••p TrV cn 0 SMtlpw TmKh O Bed 0 ManO 5'J&513 Dew LEGAL DESCRIPTION Sod B'a°0Tow 2 DepmeomanarWaraa e GPOM1IL FI. BiLa su .con: #f / D•pm to PPO W= horn dn4.W dna Govt depth bana•e Ppe 1{— Ft. Ft T~v ,p F.V. Seam FO added Wave ortg." er.de y a 1 GmW L••qN � Ft. Ft. Well: New ❑ Upgrade Grave wf I D.6a Mlwaan was — Ft. FL CI vM1u6m (Pnvee. A. B. C) Total DOW asedtu 3 TOW Weorp6m w.a �` P'ps MNNW yy� fvc- 33. D FI. Ft V Fr D«w Dee D iwd S 0 swot ear eW q S p.r•v.. Dee Ne«ed - Al OS -W n FL - A1tN.!- LV►t'-/ TANK ned ZZ Sete. CavrpH"NAbo"Gro nd GPM FI. FL - SEPARATION DISTANCES Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic Absorption Lift Holding uaiUPrNate n A^� �K .$'°�O /G From Tank Field Station Tank Sever Line l: -FO Ge WON(OO Ff / 10 /Od 4 Wnn STEGE NunN•r of Compawrnn Z Swraca water /.� 100f — — LIFT STATION T r Pump Oct' NW aL 'Pump off io l et 11 NOW ON. at. Founde,m 5 � N N. Pump MaM a a Eletdnnl Nsp•ame pedarmed Cudcn Dan _ "'n" 1 BENCH MARK Ai o Location W D•aapum. LOCA -464,Z WnMd Nri4m /O 6 Fl / �/ / Inspections performed by: N ter' /t �F.+� ��, Dates: 7" / ds EQ1 A ..... (fc.�e•r eC,gsl�� 2nd /a O $- i �AQ''•e , e'• �q,j •�'. Development Services Department Approva /7/07 01 f49L Date: �...r... e.....e ��` Conditional Approval O �... «....•..1•••••••• ...Q A to Sloven W. Eno I�� �1•• PE 6256 V�,% Reviewed and approved by: Date: 0 ' C 7 nwv 0•e6) 161 O m r o z �_ � C 3 tj < 3 tj fTl m x y h z A O G1 O %< �. C-) Ul 3 bd —I (3j M C3 T o z / r v o m N 3 r (D Ln m �+ o o Q� N O W n n 0 C3 \ ! �^ ` L3 \ / rum- pn' N N �p � . UI �O C (n ON GJ � .p w r (.n N V rtj0 o � �o v '*t Z � o O <+.� 3 kn ro 3 n 3 -c r� w 3 D �. o n 3 h 3 O (O � I r- N O W 70 / 0 C-) car=^0CJ-))�^ b 0 N 3' b( -)- ho O N N ID ' . 01 110 v O CA ON (a rtyw �°o v V,Cf- TI Z Z O O C+ 3 tn W 3 I0 Q N 3 3 n C+ c-) P �� :N -n \0 5-0 (C) 3 0 N W N v (7 M ro p 7C o C-) Z r = o r = vi 0 N O W 70 / 0 C-) car=^0CJ-))�^ b 0 N 3' b( -)- ho O N N ID ' . 01 110 v O CA ON (a rtyw �°o v V,Cf- TI Z Z O O C+ 3 tn W 3 I0 Q N 3 3 n C+ c-) P �� :N -n \0 5-0 (C) 3 0 N W N v n V O� UI A Si N" t=j I*'Ir:03 -n rriiv .0 �Z N DN�N NdN rpC m- c g(0 rho a�h-s Z °� a b o x 2 CL Z °,0 1 n o 3 (Dp3z'numtnp M 3 mho o ham•:= 11 -3 H � U# '+ 0 C) h l'•1 M -ry 20 3 �D 3 v O �3 p 0 rN Nn Ln O .» N'0 -505 N-":5 � O S D C N h Sj1� V n N3 y,QN 3 3 VI O "W ., lllx # 3P n 3 m �M N ZO .� Cp 3 r o Z —1 3 'n h� 3,0 O L'1 � p p c00h : N O C D0 3 p 3 . S f0 0 p JC n3 N C C 0 N 3 ^0 C") Z�fl C3 S -4 N < p fo'0 pNfo Q p h�Ul� 7C h 0 70p C M 3 E nn h d D -0 S D u� 3 —I --A 0 n + w n d o 0 303 70 Z m 5 n< v a D 3 ,� n ri - m z -4 -D D p r--� Z D Q P p n Gl m PC C-) 0 f N " 3 O %D 3 M CD n m F n m < < h < �o N p p < p < C) h h N h p W 3 ,+ o r C7 3 3 ty 3 0 p 7 3 n 3 � S co it 0 "1M n. + rn A� o �m fDfD G1 D W u ---I O h s 3 3 O W. -4 �A 5 W N r 0 N N O C n m M W S CNV Date: 7/19/07 To: Deb Wockenfuss 1110A On -Site Services MEMO Steve Eng, PE, PH PO Box 770724, Eagle River AK 99577 (907) 694-7028 tel NorthRimEng@aol.com Subject: McKinley Heights SID #1, Block 7, Lot 1 Permit # SW050330 Debby, Number of Pages: 3 During construction inspections in October `05 it was determined that the driveway was cut too close to the wastewater system. The house also was built too close to the absorption trench @ 9 feet set -back instead of the required 10 feet. The owner of the property was alerted to this fact. The owner, being a Civil Engineer, opted to enter into discussion with your office to alleviate the problems. I understand that this discussion did not take place and we are attempting to finalize the project. A slope setback drawing has been produced. Before we submit for a C.O.S.A. certificate we would like to obtain approval for the above discrepancies. Please review and if favorable, we will submit the as -built with C.O.S.A. request. We also plan on addressing your previous concerns for Lot 2. Thanks -Steve LO :2 Yn3 A'oMaAIJC[ O L7 d d_ z� 75 _E Q� E Q) O 75 L `I- d O 3 N Ul CD d CD C CU d � O O_ O V) a Q Q 4-> 3- L1 0 0- ) U C5 to -� O O U U UO d �7 d 0 W J r� W J Y Z U Y U J X P:l . 1 in L -L- f= / \ 0 0 / / I �,D : 9 p U O J .� Q O H O Aa W 2 J oci U 3 +' - WO £ N d 3 W = J n °i L vl d Z_ Y CD m tA N >' O O p W U pq Z LL \ U ~ d Ctn o_ n, lfl 0, o (/1 A J \ s �.z ME a J\ 00 O I J \ J d MN LO LO �� 3 D A((U7 G I i Q V J Z ?b \ Q F— �� J O v LO o ON Locu cu i� •a LYb ,, b1S«. ..•,r F- Z N -Ljq -Z N �� r:o L? F: L5 O � LWiI < q lifnfnAU U �? min Z60 4.W M -W Drilling, Inc. ♦P.O. Box 110378#Anchorage, AK 99511• •907-345-4000 ♦ 907-345-3287 Fax• Job No.: 06-107 Parcel No.: 051-213-21 Permit No. SWO50330 Permit Dated: 01 Sept. 2005 Groundwater Well As -Built & Log ♦Well Owner: Stefrensmeir, ♦ Legal Description: McKinley licights S Construction ♦ Hole Depth: 340' ♦ Casing Sl e: 6" • Cased To: ♦Drill Afethod: Air Rotary ♦ IVall. 0.25" ♦ Use of R ell: ♦ If ell Completion- Open end X Screen _ Perforated ♦Screen/Perforation descriptlon: None ♦Grout Notes: (10) Sacks- No. 8 bentonite granules; 10" fl Domestic 43' ♦Aloterlar. A 53 Steel Perf. Afethod: to 43', ♦Disinfection: Yes No Method: Chlorine Tablets ♦ Well Development., Afethod: Air surge Notes: ♦Static water level (SIVL) 295.5' (above) (below) top of casing (TOC). • 11 ell yleld test at 2 gallons per minute (GPIf)/gallon"w"ear{GP11)for 1 hours Willi 100% of drawdown (DD) from static level (S;VL). ♦Afethod: Airlift 8 ♦ Date started.. 30 March 2006 ♦ Date ofcompletion: 05 April 2006 •Pumpinstal fractures Depth In feet from top of casing. Details of formations penetrated, size of material, color and hardness. 0 TO 2.5 Casing stickup 2.5 TO 8 Fractured and weathered bedrock 8 TO 340 Bedrock: black siltstone ar illite, small water sea s insporadic fractures TO TO 1.0 gpm by 200' TO 1.5 SpIrt by 300' TO TO 2.0 g m by 340' TO TO TO WAYNE-E, WESTBERG I R9edentM-W-Dr1111ngjnc� TO TO ,. NOR Certified Master GttwOdaaW Cattractor Corttractors Ucertse No.1000 TO TO MUNICIPALITY OF ANCHORAGE Development Services Department D VVV On -Site Water& Wastewater Program \, O\� 4700 South Bragaw Street 1 ` lel P.O. Box 196650, Anchorage, AK 99519-6650 \O (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SWO50330 Date Issued: Sep 01, 2005 Expiration Date: Sep 01, 2006 Parcel ID: 051-213-21 Legal Description: MCKINLEY HEIGHTS #1 SUBDIVISION BLOCK 7 LOT 1 Design Engineer: 0838 North Rim Engineering Owner Name: CHUCK STEFFENSMEIER Owner Address: 18221 AMONSON ROAD CHUGIAK , AK 99567 - Site Address: NHN AMONSON ROAD Lot Size: 41382 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ❑✓ Disposal Field E Septic Tank ❑ Holding Tank ❑ Privy ❑Q Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 1 BAAC72 ) and Drinking Water Regulations (18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: G� Date: Issued By, //or \ Municipality of Anchorage 1 Development Services Department Building Safety Division _ On -Site Water and Wastewater Program 4700 Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 05/-'q/3 / Permit Number SW Property phone, 490y—'3071< Mailing address JeP2 Z / AC4jdAj 0K.) 1046 Zip Code T f s'`A% Site address Zip Code Legal description (Lot, Block & Sub'd.) n /��� tf/ 97 -- Legal % Legal description (Section, Township & Range) Lot Size L4131 Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms Sewer Only ❑ Well Only ❑ Sewer and Well ,® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. Permit/Rush Fees: 440-04 IRS --60 Waiver Fees: Date of Payment 213010 zJ Date of Payment: Receipt Number., 6tT_ Receipt Number: (Rev. 09/04) bTF�IM ENGINEERING NorthRim Engineering 17237 Bear Paw Circle Eagle River, AK 99577 907.694-7028 August 29, 2005 MOA On -Site Water & Wastewater Program 4700 Bragaw St Anchorage, AK 99519 RE: Septic System Design & Well Location; McKinley Heights SID, Block 7, Lot 1 A lot is being developed. Suitable soil was discovered. This is a new septic system and water well. Some of the neighboring lots are developed. This site should not negatively impact any of the other area lots. The drainage slopes from back of lot towards front of lot toward Amonson Road. Adequate separation exists between the proposed site and neighboring lots. Please review the wastewater system design for the single family home. I have included design plans & specs, design guidelines, & soil tests. If there is need for additional information or clarification please give me a call. Sincerely, eve ng, PE Design Enclosures 1TF�IM ENGiNEERiNG MCKINLEY HEIGHTS S/D, Block 7, Lot SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: This is a future single family home projected at 4 bedrooms. This requires a 1250 gallon septic tank. This lot is over 1 acres in size, as are neighboring lots. Some of the neighborhood lots have been developed. No adverse impacts are expected from developing this lot. The proposed water well is located on the drawing as are the neighboring wastewater systems & water wells. The lot slopes from back to front, toward Amonson Road. Portions of the lot are over 25% slope; the area of the septic system is about 20% slope. No conflicts to any neighbor lots is anticipated. One soil test was conducted; a silty gravel soil with an excellent percolation rate. An application rate of 1.2 GPD/FT= with 0.5 reduction factor for utilizing a 5' wide trench was utilized. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. • Two compartment, 1250 gallon septic tank. • Watertight couplings on inlet & outlet. • 5 foot minimum between the tank and bed. 10 foot to property lines. • 3 feet of cover or insulation is required for trench; an equivalent of I" insulation for each foot soil cover. • Tank & solid pipe must be set on well compacted, stable soil. • 4 inch diameter cleanouts with airtight caps are required 1 to 4 feet from foundation wall, prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10 feet from the tank positioned to provide cleanout access towards the tank and towards the absorption field. • All cleanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. • Trench to be placed level, minimum of 4 feet to groundwater, 6 feet to bedrock from drain - rock. • Drain rock to be %3 inch to 2'/: inch screened. Drain rock to be distributed uniformly throughout the trench. • Perforated pipe to be installed level with perforations down. • Silt barrier (filter fabric) to be installed above the drain rock. • Smeared trench sides must be raked or scarified before drain rock placement. • Backfill over drain rock must not be less than 36". • The finish grade must be mounded to promote drainage over the trench. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2% slope. • Septic Tank to be pumped every two years or when required. • Insulation board to be extruded direct burial polystyrene (Dow Styrofoam III or equal) C: O) O_ s ti o "r O O CL (j) to A J \ 0 C c od J F- d LD U C:) -p Lr -)a CU a, E O N J Zw o U O 00 c o 3 O -- N n E J o N V1 C O U O U U F- cn n> O _ E 0 C _, j Ecn o � D o L D ,0 O •O U •� � UJ ~a) 0 Z Z o fO- U W L- 3 (n U 4m F� > a) J o V_ U U W o dS N N7 F— L6 0 C c od J F- d LD U C:) -p Lr -)a CU a, lf) F— O 14 1 1-4 F' w CO Zw LLI -F U U JIw ,Z .D dS A F— O N J Q N O ~ N W Pa LIQ J O 2 J F— -� � 0:: lf) F— O 14 1 1-4 F' •c7 VACANT LOT eptic System Constructlon New Does Not Preclude Adjoining iC J'p Lots From Sonitatlon lr Septic New rVacant ents. System 10• util E_nt——WP1l—. 900 ,E... .:38913 128.3a N59.59'00"w 1155.06 (P629A) Vacant 5 6 E 4 i i eptic Well a - NOP, THP,IM Et4GI14EERING 17237 Bear Paw Circ/41 Eagle Rl~. Alaska 99377 907.694.7026 " MCKINLEY HEIGHTS BLOCK 7, LOT 1 LOT PLAN z/'�p11 I' = 50' — SUBDIVISI❑N LAYOUT • -- -_ 8/29/05 , 12au/4 __ p u U N W V a v Y N L UL OI ~ N U U L U O 0 O oa N ¢ u m y > ,-O Q d CL >1 o w L •N s 0 CL aN�+, 0 N LN C Q i N U N sa Ln c 0+3' 03 3 L 3— U -0t� u� nom Ngo, -P`+- o �p U. L�OISE W E Cy LL C a UN LOJ L s O O 'a O 0)UP L) to F- Y '6 > t t ° L C V1 LOL OI dam H 4-f- Nye dY a, -P O O Gi I CLL L M z ,L J— L LN 0 3:p U W L3 aa+°� 3 0 �3 w a; Vl q V1 N V1 3 V) Q Q: V) W 41 .-i fV (h 4 N kO I4Z i LD W p 2 J w� J Y � U Y O U J :5—: (q v O Sh Y LLI Z Q f- Q Z H OZ w W > U N w Z J LdLd W W N CI0 on 3 0 ct 0 Ix ti W a � ( Q 0 h e ZW ^o W § \ � t; 5L y a ) I �,- 41 ����cl / 0 £ +! - t j L fca \ mu u . 2 $ § A� �Ua) 5 tn Q,, 2%f; L{ AI -°C$V co C5 �L*2. 4'M>L Atm CL §, >�s: aUL) 0 u a) r -P r; § F - E - k Iu� z45yC: LO o- meneIr) , N4w¥; / 2 u C$ y a ) /z LLJ / #4■� t� ; - j � fca �' t 3§I � m. K m %�■w >f� ) ��\ t a� � ■; i { . i � # ■®�. / ■��. - ���. j. ff � 4t o — / & \ �u ƒ CL , • C$ IL /A t § :3/ t t t t \Z k( /z LLJ #4■� t� ; - � fca �' t 3§I � m. K %�■w >f� t a® MA� • t a� � ■; i i � # ■®�. ; � # ■��. - ���. . � 4t — Ki¥i � � $ , • \Z k( /z LLJ fca 3§I � 2 SOILS LOG - PERCOLATION TEST Thi M _ Date Performed: 8/18/05 ENGINEERING Performed For: Chuck Steffensmeier Legal Description: McKinley Hts, Block 7, Lot 1 DEPTH (FEET) T.H. Location: See Drawing Organic GM Silty Gravel w/ Low Silt Groundwater7_No Depth Water Depth LA All, r5 nn+o, a/pr/Iig1 pi 1,rr # rrv, I Date W. Gross Time Net Time Depth Net Dro 1 6/3 3 -- 4 -.: - 5 - "s 6 2 min 6' 1' 7 - 6/3 3 -- 8 - 4 6/3 5 2 min 9 1' 10 6/3 6 -- 11 • 6 „�• 8 2 min 13 - , :•, 14 - 15 - 16 - 17 - 18 - 19 - 20 - 21 - T.H. Location: See Drawing Organic GM Silty Gravel w/ Low Silt Groundwater7_No Depth Water Depth LA All, r5 nn+o, a/pr/Iig1 pi 1,rr # rrv, I Date W. Gross Time Net Time Depth Net Dro 1 6/3 0 -- 5' - 2 6/3 2 2 min 6' 1' 3 6/3 3 -- 5' - 4 6/3 5 2 min 6' 1' 5 6/3 6 -- 5' -- 6 6/3 8 2 min 6' I' Percolation Rate 2 min./Inch Perc Hole Diameter 6= Test Run Between4' and5' Comments' PrP-SOak d ,OOd rPric Performed ByNnrthRim Eng. I Performed in Accordance with A ON THIS DATE, DATE: 8/26/05 NORTHRIM ENGINEERING 117237 Bear Paw Circle ,Eagle River. Alaska 99577 907.694. 7026 CERTIFY THAT THIS TEST WAS i State/Municipal Guidelines in Effect TESTH❑LE GE❑TECHNICAL iI T. H. 1 pate OcEr — 8/26/05 11 of I Parcel I.D. 051-213-21 er a� Municipality of Anchorage On -Site Water and Wastewater Program q ` (907) 343-7904 Certificate of On -Site Systems Approval 1. GENERAL INFORMATION Expiration Date: Complete legal description McKinley Heights #1, Block 7, Lot 1 Location (site address) 18221 Amonson Rd. Current Property owner(s) Mailing address Real Estate Agent William & Kay Humphries Day phone _ 18221 Amonson Rd. Chugiak, AK 99567 Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) t; ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System WaiverNariance request for: Received by: COSA to be released to i TYPE OF WASTEWATER DISPOSAL: ❑ Individual 0 ❑ Holding Tank ❑ ❑ Community ❑ ❑ Public Sewer ❑ Date: r f requested by the engineer. COSA Fee $ 52(P Waiver Fee $ Date of Payment ��ricJf ��( (� Date of Payment Receipt NumberC��[2 �G Receipt Number COSA# m)c) -i Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MCA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The Content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Alk. 99510 Engineer's Printed Name Steven R Pannone Date 9/18/2014 EXIAW1 \� 6. DSD SIGNATURE "' >`. "•"""•. Lll System #1 Approved for —f— bedrooms Steven w ahrione CE 8149 System #2 Approved for bedrooms 4 . Sc V Disapproved ���[l� �OFESS" Conditional approval for bedrooms, with the following stipulations: By: ,� <t' Original Certificate Date: l 0 i� � The MICipVrty�1of Aeiefiorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory _"Sli Other COSA blue sheef f .. If more than 1 septic system is on the lot: COSA Checklist # I of Structure served by this system 1 Certificate of On -Site Systems Approval Checklist Legal Description: McKinley Heights #1, Block 7, Lot 1 A. WELL DATA Well type Private If A, B, or C provide PWSID # Date completed 4/5/2006 Sanitary seal (Y/N) Y Total depth 340 ft. Cased to 43 ft. FROM WELL LOG Date of test 4/5/2006 Static water level 295.5 ft Well production 2 9-13 m. Parcel ID: 051-213-21 Well Log (Y/N) Y Wires properly protected (Y/N) Y Casing height (above ground) 18+ in. AT INSPECTION 9/15/2014 133 ft. 0.5 9 - p.m - WATER SAMPLE RESULTS: Coliform N E 61 colonies/100 mL Nitrate N D mg/L Arsenic WD ug/L Date of sample: 9/15/2014 Collected by: PES B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1,250 gal. Number of Compartments 2 Date installed 10/4/2005 Cleanouts (Y/N) Y Foundation cleanout (YIN) Y Depression over tank (Y/N) N High water alarm (YIN) N Date of pumping 12 i Pumper C. ABSORPTION FIELD DATA Date installed 10/4/2005 Soil rating (g.p.d./ft2 or ftz/bdrm) 1.2 GPD/SF System type Shallow Trench Length 52 ft. Width 5 ft. Gravel below pipe 4 ft. Total depth 8 ft. Eff. absorption area 520 ft Monitoring tube Y Depression over field N Date of adequacy test 9/15/2014 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test 0 in. Elapsed Time: 140 min. Final fluid depth 0 in. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NO Water added 606 gal. New depth 0 in. Absorption rate >= 600+ g.p.d. If yes, give date D. LIFT STATION Date installed "Pump on" level at Datum Size in gallons in. "Pump off' level at E. SEPARATION DISTANCES WELL ON LOT TO: Cycles tested Septic tank/lift station on lot 100+ Absorption field on lot 100+ Public sewer main 75+ Sewer /septic service line 25+ Animal containment areas 50+ Manhole/Access (Y/N) _ in. High water alarm level at Meets alarm & circuit requirements? On adjacent lots 100+ On adjacent lots 100+ Public sewer manholelcleanout 100+ Holding tank 100+ Manure/animal excrete storage areas 100+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5+ Property line 5+ Water main 10+ Water service line 10+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water Service line 10+ Surface water 100+ Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS Water system has 300 gallon holding tank. G. ENGINEER'S CERTIFICATION Absorption field 5+ Surface water 100+ Water main 10+ Driveway, parking/vehicle storage 10+ i ,�..... rte. t certify that I have determined through field inspections and ✓.rg+�P �9 review of Municipal records that the above systems are in M,F-SevW '•,* conformance with MCA COSA guidelines in effect on this date.... , Engineer's Printed Name Steven R. Pannone 3onnon.... 9/18/2014-8149 Date '�. COSA brown sheet 10-10-12.doc in. Municipality of Anchorage as a Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. ci. anchorage. ak.us (907) 343-7904 Water Well Advisory Certificate of On -Site Systems Approval (COSA) # 141508 During a recent COSA on-site inspection and test of the potable water supply well on Block 7, Lot 1 of McKinley Hts. 91 subdivision, the well's productivity was determined to be 0.5 gallons per minute. The minimum well productivity required by this Department (AMC 15.55) for a 4 -bedroom residence is 0.41 gallons per minute. Although the subject well currently exceeds this minimum requirement, all parties concerned are advised that the production capacity of the well may fluctuate. Restriction of non-critical water uses such as washing cars and watering lawns and gardens may be required. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. CS Municipality of Anchorage o' Development Services Department �� / Building Safety Division On -Site Water and Wastewater Program ` 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D.a 5/"- Z/3-ZI COSA# Expiration Date: / D -10 7 1. GENERAL INFORMATION Complete legal description Location (site address) Current Property owner(s) _Yc/C%G S%F.fFE &*vf(IL Day phone CM- O°33 Mailing address Lending agency Mailing address Day phone Real Estate Agent A'ji JOAJ Day phone d -ZZ "33[Ey Mailing Address Pi,An f)e of ?s4cr.6 /2mc-fte- Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm 4oy- �-t rs. FINC py— Phone %0-zr}- Address! Fu 6O< :z -?,,2q Engineer's Printed Name "S!7 F'✓F_ 45AJ G Date Z�? 040 7' qtr OF 49— .......... t -;•c .........«..:... ' Y� F• � Steven W. Eng y. 5. DSD SIGNATURE i` FE ansa40 Approved for �^ _ bedrooms. t�itp�•PdoFEsstq�P-- Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory WATER AND Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: !ve Original Certificate Date: (Rev.11,05) Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water & Wastewater Program • • °' 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-850 www.muni.org/onshe (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: /1c1c��/ 1 9146tG 7 L* f L Parcel ID:O S/ -Z/3 -2t A. WELL DATA Well type P If A, B. or C provide PWSID # _ Well Log (YIN) � Date completed4ffVO6 Sanitary seal (YM) Wires properly protected (Y/N) T Total depth ILL6 fl. Cased to �,_ft. Casing height (above ground) stn. FROM WELL LOG Date of test S O'6- Static water level _-0 � S .s fl. Well production Z g.p.m. WATER SAMPLE RESULTS: AT INSPECTION i(/f..r..) ft. 9.p -m. Coliform ! coloniesl100 mL Nitrate o. ro mg1L <*a Other bacteria Q colonies/100 mL Arsenic: 0, 2 i 7 **Date or sample: 1 07 Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material 44k- 09AMce�'y��"T' f� Date installed _/0J666 S Tank size IZ5C3 gal. - Number of Compartments Foundation des rout (Y/N) 4— Depression over tank (YM) _A(L Date of pumping 44a6J- Pumper Cleanouts (Y/N) y High water alarm (Y/N) At C. ABSORPTION FIELD DATA Date installed 1011410.5 Soil rating (g.p.dJfe or WFhdnn) /.Z System type 796UC.ft Length .SZ ft. Width 5' ft. Gravel below pipe Y ft. Total depth - ft. Eff. absorption area ZO ft' Monitoring tube -Y_ Depression over field AL_ Date of adequacy test Xt�oJ Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test _ In. Water added_ gal. New depth_ in. Elapsed Time: _ min. Final fluid depth _ in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (YM & type) If yes, give date D. LIFT STATION Date installed 'Pump on' level _ in. Datum E. SEPARATION DISTANCES Size in gallons "Pump off" level _ in. Cycles tes SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAift station on lot _/6O r f" Absorption field on lot 14 6 r ! Public sewer main Sewer /septic service line /O O f& ManhoielAccess zel High water alar Meets ala circuit requirements? On adjacent lots 400 rf- On adjacent lots l Q Q ,,- Public Public sewer manholelclearwut AiIA Holding tank Animal containment areas /O 0 rt Manurelanimal excrete storage areas 40,1 rr SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation Property line / Absorption field S / Water main 9X Water service tine Z S t Surface water Wells on adjacent lots 44 r{' In. SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line rt Building foundation" s r f Water main Water Service line �0 It Surface water /00 r* Driveway, parkinglvehicle swap SEs f Curtain drain Wells on adjacent lots 60 t F. COMMENTS G. ENGINEER'S CERTIFICATION : p�c•••":tiS�� + 1 I certify that I have determined through fled inspections and* .49M* :k review of Municipal records that the shove systems are in i • • conformance with MOA COSA guidelines in effect on this date. N Engineer's Printed Name _J`—Tt�� /_ i.1 G �I, ��"�� "4 7%aa�� rF, •'• Date � �I:Fn,:'•......•;'A` :� COSA Fee $— Date of Payment �f 0 Receipt Number 02.57-.1)a",o (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number _- _ .. ._. - . . _.. . Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196850 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWERIWELL SUBMITTAL COMMENT SHEET To: Steve Ena Legal description: McKinley Heights #1 Block 7 Lot 1 ®Permit ®C.O.S.A. ❑Inspection Report The attached paperwork has been reviewed and is being returned for the following reasons: 1. Field less than 35 feet from a slope of 25%. 2. Field 9.5 feet from foundation. 3. Tank 4.5 feet from foundation. 4. No area for altemite site as shown on Inspection Report 5. Excavator NOT MOA approved. Name of reviewer: M Date: August 22, 2007 Please supply the necessary information and re -submit your request. LEAVE THIS FORM ATTACHED TO THE PAPERWORK GROUP Northrim Eng Atm: Steve Eng 17237 Bear Paw Circle Eagle River, AK 99577 907.694-7028 Fax: 907-694-7026 Client Sample ID: Sampling Location: Chugiak I Client Project: Northrim Eng Sample Matrix: Aqueous COC #: PWS#: Residual Chlorine: Comments: Lab#: A0707179 -02A Analytica International, Inc. 4307 Arctic Blvd. Anchorage, AK 99503 Phone: 907-258-2155 Fax: 907-258-6634 Report Date: 7/30/2007 Receipt Date: 7/16/2007 Sample Date: 7/16/2007 Sample Time: 9:30:OOAM Collected By: T Eng Hatt Definitions: MRL = Method Reporting Limit MCL = Maximum Contaminant Limit B - Present also in Method Blank 11= Exceeds Regulatory Limit M = Matrix Interference J = Estimated Value D = Lost to Dilution •• = RL higher than MCL; target not detected TNC = Too Numerous to Count - result rejected CF = Confluent Growth - result rejected TCNG = Turbid Culture No Growth - rejected Analysis Method Prep Prep Analysis Parameter Result Units Flags MRL MCL Method Date Date Analyst 92228 (Aqueous) - Membrane Filtration MF Test was conducted by: Analytica - Anchorage Bacteria, Other <MRL CFU/IOOmL 1.0 7/16/2007 7/16/2007 PL Total Coliform <MRL CFU/IOOmL 1.0 1 7/16/2007 7/16/2007 PL Lab#: A0707179 -02B Analysis Method Prep Prep Analysis Parameter Result Units Flags MRL MCL Method Date Date Analyst 4500-NO3E (Aqueous) - Nitrate Test was conducted by: Analytica - Anchorage Nitrate as N <MRL mg/L 0.10 10 7/17/2007 7/17/2007 Al Lab#: A0707179 -02C Analysis Method Prep Prep Analysis Parameter Result Units Flags MRL MCL Method Date Date Analyst 200.8/200.8 (Aqueous) - Family Well Water 1 Test was conducted by: Analytica - Thornton Arsenic 0.287 ug/L 0.15 10 200.8 7/24/2007 7/24/2007 KS Reported by: Claire Toon, Laboratory Project Manager Page 2 of 2 b6T�I,Rim rr�',IlrMEMO Date: 9/7/07 To: Jeff Poet AfOA On -Site Services Steve Eng, PE, PH PO Box 770724, Eagle River AK 99577 (907) 694-7028 tel NorthRimEng@aol.com Number of Pages: 1 Subject: McKinley Heights S/D #1, Block 7, Lot 1 -Waiver Permit # SW050330 Jeff, The separation distance from septic tank to foundation is 4.5 feet. This should not negatively impact the foundation as the tank is adjacent and elevated. Foundation will remain stable. The separation to the absorption field is 9.5 feet instead of the required 10 feet. The drain -field is downslope R. dowmgmdient. The drain -field will work as intended in this instance. Thanks -Steve Lot � ! Lot 5 j Lot 6 PLOT PLAN _ An L J'Z,' „ SCALt1- 1510' GRID NW -10-53 Project HOA.j-172 Lang 6G Ns.sociatt95e Inc, IHUD Daryl Avenue, Anchorage. Alaska 99S1S,-3049 (907) 322-84711 Phone Reglsiormd Land Surveyors (907) V2-4625 Fox _ _ _M en bOnlr_kcr,e! ^len teoolayko.ne{. CI•,•••!,(,gSp�a I homby rortlty that I have P,trre,-.d fh• 101vwtn0 desertbed property __ �P' +(•I"� LOT 1. BLOCK 7, N0(19LEY HEIGHTS SU90MSION ;' L}g + •:pyr Anahcn gu it•oortln G1e":et, .Vasks. and that the imprawmants aMuated thereor, are.................. • ,..•.. / ........ JJJ wHhLt "to pnoperf!ru.!eot s ra:! neneneaeh enta the properly adjaeent fh•rsk•, tld N,. �+}.• na Improyernents an the property Mnq adjaoent th"o sncrso,!h on the sulveprd pfttAte.m and that tl:xa art im rcutuv,- , fransndealon DKtnes w vlh•r risible �• Y rrH eas,r»ants on sold r^ -r 4r re,3..r.l w 01cafed hsroon. -5202 Doted this the 704 T.y of Ziuy L24Z. of Anchorog*, Alaska 1t la the rssponNbtlify of the owner to dets•rtrine the ezt:fenoe of any eoeementi, `y yzssa+�: eev.naMl nr rywt+t.:.:u:a eP,:z:: I+.•• 1++-t a+.na,w u:. $.. r.e M.A w1.4.